LIVE CASE STUDY CHILLER PLANT COOLING TOWER SEASONS MALL PUNE HADAPSAR TAHA B. AMAAN S. RUFIYA S. ZIAN J. AYUSH J. SEASONS MALL,PUNE About Seasons mall: ● Built on a plot of 12 acres, the Mall is a located within Magarpatta City and representing a unique destination, with stores, attractions and services combining to form the most comprehensive and integrated retail, hospitality and entertainment complex. ● Seasons Mall is a place where people come to shop, play, dine and a have a memorable experience. ● Seasons Mall is home to over 100 brands, 25,000 sq. ft. of food court, a 15-screen Multiplex and a 90,000 sq.ft. Hypermarket. ● By reflecting and enabling customer lifestyles and delivering affordable luxury with a philosophy of 'customer first' ● the Mall has distinguished itself as something truly spectacular on the retail landscape. Location: Hadapsar Website: http://seasonsmall.in/ Phone: +91 20 6722 4000 | 6722 5000 Facebook URL: https://www.facebook.com/SeasonsMallPune Twitter URL: https://twitter.com/SeasonsMallPune LOCATION CHIlLER SYSTEM AHU-FILTERS AND GIVES AIR TO SPACES WARM WATER FROM CHILLER PLANT TO COOLING TOWER FROM AHU DUCTS TO SPACES USED AIR FROM RETURNED DUCTS TO CHILLER PLANT PROCESS BACK TO CHILLER PLANT SKETCH SCHEMATIC PLAN & SECTION OF THE SYSTEM CHILLER SHOWING INLET AND OUTLET CHILLER PLANT COOLING TOWER & SUPPLY FROM HERE IT GOES TO THE AHU AND FROM AHU TO ALL ZONES ARROW ON TH PIPE INDICATES THE DIRECTION OF FLOW COIL AIR GAUGE To analysis the force of fluid mainly it is of 50 – 100% FILTERS BLOWER The pipes are wrapped with Armaflex LIMIT SWITCH AIR HANDLING UNIT Distance between AHU and wall is approximately 1m AIR HANDLING UNIT AIR HANDLING UNIT SCHEMATIC SECTION OF STAR BAZAAR SECTION LOCATION OF AHU OF STAR BAZAAR CONCLUSION cooling tower and chiller room are housed in a separate structure, whilst the AHU are located within the mall. •Cooling towers were situated on the roof; one cooling tower was operational, while another was merely recirculating water to keep it cold. •The pipes are wrapped with Armaflex, which serves as insulation to keep the water cold and dry. •On weekends and holidays, when there are more people, they • 2-3 chillers; otherwise, on typical days with less people, they use one chiller. •There are five pumps, two of which are operational while the rest are in standby mode. •The AHU we saw was only for the Star Bazaar region; this large area requires nearly two ahu, whereas small areas require only one which are situated within area CONCLUSION •LOCATION: The