Holy Angel University School of Engineering and Architecture Department of Civil Engineering Name / Student No. : _______________________________________ Section and Schedule : _______________________________________ Date of Examination : ________________________________________ Instructor : ________________________________________ RATING MIDTERM EXAMINATION BLDGDESIGN First Semester, AY 20 21 - 2022 GENERAL INSTRUCTIONS 1. This is a group project. Each group consists of 5-6 members. Each group should select a leader. 2. Title block will be given by the instructor to ensure uniformity of the template. 3. Floor area should have a minimum area of 100 sqm. and a maximum area of 300 sqm. 4. The Two-Storey Residential Floor Plan should have the following sheet contents as indicated to the checklist section 5. Apply the theoretical concepts learned in building design into practice by creating a 2 Storey Residential Structural Plan that will serve as a preparation in creating one of the most important documents in every construction project. 6 . Apply the provisions of the National Structural Code of the Philippines used in step-by-step process of planning, orienting and drawing. 7 . Conduct the actual drawing of an structural plan for the proposed building (PDF file). RESOURCES National Structural Code of the Philippines National Building Code of the Philippines DISCUSSIONS: CHECKLIST:2 STOREY STRUCTURAL PLAN Foundation Plan 2nd Floor Framing Plan Schedule of Columns Schedule of Beams Schedule of Footings Reinforced Concrete Slab Details Roof Framing Plan Truss Details Schedule of Wall Footing Stair Details General Notes others SUBMISSIONS The compressed main folder should be uploaded on Canvas. Deadline: October 15,2021 One (1) point from the total score should be deducted for every 5-minute late submission. Name the File BLDGDESIGN_CLASSCODE_GROUPNO_GROUP NAME o Example : BLDGDESIGN_4521_GROUP1_STEEL_ MIDTERM EXAM / BLDGDESIGN Page 1 of 2 Rubric for Assessment Category Weight Excellent 4 (100%) Proficient Acceptable Needs Improvement 3 (75%) 2 (50%) Demonstrates considerable understanding of the considerations necessary when building their own structure, and the design plan is complete and all components have Dimensions were present discussed. onbeen the majority of the project with several inaccuracies that did not affect overall understanding. All schedules were completed. Demonstrates some understanding of the considerations necessary when building their own structure, yet the design plan is missing some essential Dimensions components.were present on some of the project with inaccuracies that affected overall understanding. All schedules were completed but with some inaccuracies. Demonstrates limited understanding of the considerations necessary when building their own structure or the design is missing or incomplete. 1 (25%) Grid system is somehow dimensioned and coordinated with architectural drawings. Grid system is poorly dimensioned and coordinated with architectural drawings. Design 20% Accuracy of Dimension and Completeness of Schedules 20% Grid System 20% Grid system is fully dimensioned and coordinated with architectural drawings. Grid system is mostly dimensioned and coordinated with architectural drawings. 20% Overall design complied with the provisions of Building Code. Overall design fulfilled the parameters within expected range of work but some minor mistakes were made. 10% Highly-detailed drawing Considerably-detailed drawing Somewhat-detailed drawing Little or no detail included in drawing 10% Very neat and organized throughout the drawing Considerably neat and organized through most of the drawing Somewhat neat and organized on some parts of the drawing Messy and disorganized through most of the drawing Compliance on the pertinent provisions of Building Code Detail Neatness and Organization Demonstrates thorough understanding of the considerations necessary when building their own structure and the design plan has been completed with considerable detail. Great time and effort were spent to ensure 100 % accurate notes/dimensions throughout the entire project. All schedules were completed and accurate. MIDTERM EXAM / BLDGDESIGN More than half of the requirements are fulfilled and translated accurately. There were minor mistakes that can be corrected with minor revisions. No dimensions were present on the project. Schedules were incomplete or inaccurate schedules. The work lacks complete understanding of the Building Code. Page 2 of 2 (Score / HPS) x Weight