Uploaded by ohohcehz

BUILDING DESIGN

advertisement
Holy Angel University
School of Engineering and Architecture
Department of Civil Engineering
Name / Student No.
: _______________________________________
Section and Schedule
: _______________________________________
Date of Examination
: ________________________________________
Instructor
: ________________________________________
RATING
MIDTERM EXAMINATION
BLDGDESIGN
First Semester, AY 20 21 - 2022
GENERAL INSTRUCTIONS
1.
This is a group project. Each group consists of 5-6 members. Each group should select a leader.
2.
Title block will be given by the instructor to ensure uniformity of the template.
3.
Floor area should have a minimum area of 100 sqm. and a maximum area of 300 sqm.
4.
The Two-Storey Residential Floor Plan should have the following sheet contents as indicated to the checklist section
5.
Apply the theoretical concepts learned in building design into practice by creating a 2 Storey Residential Structural Plan that
will serve as a preparation in creating one of the most important documents in every construction project.
6 . Apply the provisions of the National Structural Code of the Philippines used in step-by-step process of planning, orienting and
drawing.
7 . Conduct the actual drawing of an structural plan for the proposed building (PDF file).
RESOURCES
National Structural Code of the Philippines
National Building Code of the Philippines
DISCUSSIONS:
CHECKLIST:2 STOREY STRUCTURAL PLAN












Foundation Plan
2nd Floor Framing Plan
Schedule of Columns
Schedule of Beams
Schedule of Footings
Reinforced Concrete Slab Details
Roof Framing Plan
Truss Details
Schedule of Wall Footing
Stair Details
General Notes
others
SUBMISSIONS



The compressed main folder should be uploaded on Canvas.
Deadline: October 15,2021
One (1) point from the total score should be deducted for every 5-minute late submission.
Name the File BLDGDESIGN_CLASSCODE_GROUPNO_GROUP NAME
o Example : BLDGDESIGN_4521_GROUP1_STEEL_
MIDTERM EXAM / BLDGDESIGN
Page 1 of 2
Rubric for Assessment
Category
Weight
Excellent
4 (100%)
Proficient
Acceptable
Needs Improvement
3 (75%)
2 (50%)
Demonstrates
considerable
understanding of
the considerations
necessary when
building their own
structure, and the
design plan is
complete and all
components
have
Dimensions
were
present
discussed.
onbeen
the majority
of the
project with several
inaccuracies that did not
affect overall understanding.
All schedules were
completed.
Demonstrates
some
understanding of
the considerations
necessary when
building their own
structure, yet the
design plan is
missing some
essential
Dimensions
components.were
present on some of the
project with inaccuracies
that affected overall
understanding. All
schedules were
completed but with some
inaccuracies.
Demonstrates limited
understanding of the
considerations
necessary when
building their own
structure or the
design is missing or
incomplete.
1 (25%)
Grid system is somehow
dimensioned and
coordinated with
architectural drawings.
Grid system is poorly
dimensioned and
coordinated with
architectural drawings.
Design
20%
Accuracy of
Dimension and
Completeness of
Schedules
20%
Grid System
20%
Grid system is fully
dimensioned and coordinated
with architectural drawings.
Grid system is mostly
dimensioned and
coordinated with
architectural drawings.
20%
Overall design complied with
the provisions of Building
Code.
Overall design fulfilled the
parameters within
expected range of work
but some minor mistakes
were made.
10%
Highly-detailed drawing
Considerably-detailed
drawing
Somewhat-detailed
drawing
Little or no detail included
in drawing
10%
Very neat and organized
throughout the drawing
Considerably neat and
organized through most
of the drawing
Somewhat neat and
organized on some parts
of the drawing
Messy and disorganized
through most of the
drawing
Compliance on the
pertinent provisions
of Building Code
Detail
Neatness and
Organization
Demonstrates thorough
understanding of the
considerations
necessary when
building their own
structure and the design
plan has been
completed with
considerable detail.
Great time and effort
were spent to ensure
100 % accurate
notes/dimensions
throughout the entire
project. All schedules
were completed and
accurate.
MIDTERM EXAM / BLDGDESIGN
More than half of the
requirements are fulfilled
and translated accurately.
There were minor
mistakes that can be
corrected with minor
revisions.
No dimensions were
present on the project.
Schedules were
incomplete or inaccurate
schedules.
The work lacks complete
understanding of the Building
Code.
Page 2 of 2
(Score /
HPS) x
Weight
Download