Baseband 6620 &
6630 Commissioning
On-Site
Power Cycle Button
Power cycle your device (Turn off and on) Much like any computer, many issues are resolved by simply turning your phone off,
waiting a minute or two, then turn it back on. It's good practice to do this once or twice a week.
A factory Reset Button erases your data from the Base Band. While data stored in your Drive-C. Account
can be restored, all files, software and their data will be uninstalled.
Baseband script
Baseband Configuration Files
1. RBS Summary Script.xml
2. Site Basic Script.xml
3. Site Equipment Script.xml
4. Transport Network Script
5. Radio Network Scrip
Note: Only Files 1, 2 & 3 are loaded to the BB6620/30. Each file must carry .xml.
Which means, when manually commissioning the BB, it looks for all files with .xml.
1. RBS Summary Script
The purpose of the RBS Summary File is to define the paths to
other configuration files used for integration of a node.
Summary script is the file which is used when BB
commissioning is started.
2. SITE equipment script
>The purpose of the Site Equipment File is to handle configuration of
equipment. › The most important part is to set up the first Baseband
and the TN Port on the Baseband Unit, to enable Site Basic File to run.
› Important part of site equipment script : – Equipment such as cabinet
data, alarm, antenna, riport, rilink, etc. –
>EquipmentSupportFunction such as PSU, PDU – Node Support as
radio sector definition
3. Site Basic SCRIPT
The purpose of the Site Basic File is to set the attributes defining
security management, system management, and transport
network configuration.
Important part of Site Basic Script – Security Management –
Transport definition, VLAN, IP, Router, Transmission Port – License
Management.
Step#1:Folder Preparation
› Create a folder the following will be stored: – Baseband SW
package (17.Q3) – Msftpserver or FreeFTPd (recommended) –
configuration scripts (RBSSummary, Site Basic, Site Equipment)
Step#2: Communication setup
1. Power Up Baseband 6630/6620.
2. Connect Laptop to port LMT on Baseband using RJ45
cable
3. IP Laptop Setting
Base Band IP 169.254.2.2
PC/Laptop IP 169.254.2.1
Ping 169.254.2.2
Note: These Files, with .xml are the files/scripts written and given by the RNC-Integrator.
The most follow Netconf(.xml). This will enable the base band to be loaded and ready for integrations by the RNC-Specialist.
Note: 65% means, site Installation Complete and integration @5%, which means the site is ready to be turn on
AIR by the Integrator/RNC Specialist. This equals the total of 70% complete BB.
Step#3: Board Restore (FORMAT)
>Check Node status in Emergency Access link.
>https://169.254.2.2/ea.html › Board Restore
Button is used to format or erase previous Data
or script install on the Baseband.
Step#4: SFTP
>Server Firewall and antivirus should be disabled in the local PC.
› Setting SFTP Server (Recommendation FreeFTPd) – - IpAddress :
169.254.2.1 – - User : ftp – - Password : ftp
SFTP Server
Setting SFTP Server (Continue..) – Port 22 – SFTP root
directory is the folder where Package and scripts are saved.
APP#1. SFTP (1)
APP#1. SFTP (2)
APP#1. SFTP (3)