Homework #4 CMGT - 325 Name: California State University East Bay School of Engineering Construction Management Program CMGT-325: Electrical and Mechanical Systems in Construction Notes: (1) This is an individual assignment. (2) Answers can be typed or handwritten and scanned as needed. (3) Answer questions 1 – 12 according to the textbook. (4) Submit a digital copy on Blackboard by the date shown below. A link is provided under the Course Material - Homework section on Blackboard. Due Date: Monday 05/03/21 [25 points] 1. What three major characteristics are listed by the textbook regarding domestic water “water quality” use in a building? 2. What is a pump performance curve? 3. Please fill in the definitions of the following terms: Roof drain: Area drain: Downspout: Gutter: Leader: Subsoil drain: Controlled storm drainage system: Primary drainage system: Homework #4 CMGT - 325 Name: Secondary drainage system: Sump: Sump pump: Projected roof area or horizontal projected roof area: 4. What is the purpose of control valves? 5. Describe a reverse osmosis (RO) water purification system. 6. Please describe what a backflow preventer does. 7. When a domestic water system is abruptly shut, such as closing a faucet or flushing a toilet, what type of device can be installed to absorb the shock? 8. Please fill in the definitions of the following terms: Waste (liquid): Sanitary Waste: Homework #4 CMGT - 325 Name: Soil (waste): Sanitary Drain: Sanitary Sewer: Storm Water: Storm Drain: Storm Sewer: Combination Sewer: 9. What must you do if there is not enough water pressure provided to a building? 10. What is a hot water “re-circ” line? 11. What environmental act regulates the water usage of fixtures? 12. Regarding plumbing fixtures what is an “Air Gap”? Homework #4 CMGT - 325 Name: 13. Based on the isometric view shown (6/P3.0) label each fixture with the corresponding drainage fixture unit(s) using Table 702.1 provided. After fully labeling, what is the total quantity of drainage fixture units at the sewer main? [hint: use Table 1A provided below for terminology when reading Table 702.1] Total Drainage Fixture Units (DFU) = ________________________________________ Homework #4 CMGT - 325 Name: TABLE 1A: PLUMBING FIXTURE TERMS TAG FIXTURE TYPE P-1 Water Closet, 1.6 GPF Flushometer Tank P-1H Water Closet, greater than 1.6 GPF Flushometer Valve P-2 Not Used P-3 Lavatory – Countertop (ADA) “use as individual” P-4 Mop Basin Sink P-5 Lavatory – Wall Mounted (ADA) P-6 Electric Water Cooler P-8 Service Sink, Flushing Rim H-1 Clothes Washer Homework #4 CMGT - 325 Name: