INSTALLATION INSTRUCTIONS
UL 59-0757-5 0904-30
PASSIVE INFRARED DETECTOR
RX-40QZ
No.59-0757-7 1606-24
RX-40QZ(E) ;
EN 50131-2-2 Grades and Environmental Class;
Security Grade 2 and Environmental Class II.
Tested and certified by Telefication
Manufacturer:
OPTEX CO., LTD.
5-8-12 Ogoto, Otsu, Shiga, 520-0101 JAPAN
Authorised representative in Europe:
FEATURES
OPTEX (EUROPE) LTD. / EMEA HEADQUARTERS
Marandaz House 1 Cordwallis Park, Clivemont Road,
Maidenhead, Berkshire, SL6 7BU U.K.
- 40ft. X 40ft.(12m X 12m)Wide Angle - Improved Sealed Optics
- QUAD Zone Logic
-Temperature Compensation Logic
- Patented Multi-focus Lens
EASY INSTALLATION
PD 6662 : 2010
FUNCTION
OPTION
- Selectable Pulse Count(2 or 4)
- LED ON/OFF
- Tamper Switch
- Easy Wiring Knockout
- Wiring Guide
- Spare Terminal
- Wide Wiring Space
- FL-60N Long Range Curtain Lens(60ft/18m)
- FA-3 Wall & Ceiling Mount Bracket
(Horizontally ± 45° & Vertically 0° to -15°)
1. INSTALLATION HINTS
(1)
(2)
(3)
(4)
(5)
Avoid direct sunlight.
Avoid looking directly at air
conditioning or heating vents.
Avoid vapor or high humidity
that can cause condensation.
Avoid Curtain,Screen,etc.
blocking detection area.
Do not install outdoors.
2. DESCRIPTION AND OPERATION
LED Alarm
Mounting Knockout
(Pitch = 2.63inch/66.7mm)
Wiring Knockouts
Indicator
Tamper Switch
LENS
Terminals
Sensor
(Do not touch)
Cover Fastening Screw
Sealed Optics Foam
Pulse Count Selector
(2/4)
LED ON/OFF Switch
Wiring Guide
3. DETECTION AREA
WIDE ANGLE
LONG RANGE (OPTIONAL LENS : FL-60N)
TOP VIEW
5
PATTERN AREA SELECTION
10
15
20
25
30
35
40 ft
When selecting the long range
detection pattern , always set
pulse count selector to "2".
15
4
10
2
5
0
Use the optional lens FL-60N
for long range area.
IMPORTANT
20 ft
6m
FL-60N
Engraved
LONG RANGE
0
5
2
4
6m
10
1.5m
15
0
20 ft
2
4
6
8
10
TOP VIEW
12m
20
10
30
40
50
60ft
5ft
0
1.5m
5
10
15
5ft
18m
50
60ft
15
18m
SIDE VIEW
0
10
20
30
40
HOW TO REMOVE & FIT LENS
To remove , press both lens hooks
to outside and push to the front.
To fit , press the lens into cover
from the front .
SIDE VIEW
5
10
15
20
25
30
35
40 ft
0
2.4m 0
2
4
6
8
10
12m 8 ft
2.4m
0
5
10
COVER INSIDE
4. WIRING
TAMPER
( N.C. )
Power wires should not exceed the following lengths.
ALARM OUTPUT
( N.C. )
SPARE
SPARE
(BE) mode only
ALARM 12V DC
N. C.
- +
TAMPER SP
※ UL requires RX-40QZ to be connected to a UL listed power
supply capable of providing a normal input of 12 VDC, 11 mA (max.)
(at 12 VDC) and battery standby time of 4 hours.
5. LED ON/OFF
14 VDC
AWG 22 ( 0.33mm2 )
1700' (520m)
3700' (1130m)
AWG 20 ( 0.52mm2 )
2690' (820m)
5830' (1780m)
AWG 18 ( 0.83mm2 )
4290' (1310m)
9350' (2850m)
When using two or more units on one wire, the maximum
length is obtained by dividing the maximum wire length listed above
by the number of units used.
※ The equipment shall be installed in accordance with the
National Electrical Code, NFPA 70.
°
7. EASY
WIRING KNOCKOUTS
6. PULSE COUNT
Use the pin switch for LED ON/OFF.
N
O
12 VDC
WIRE GAUGE
POWER INPUT
(9.5 to16 VDC)
OF
Press firmly with a screwdriver to open.
Enlarge the hole according to size of wire.
Use the pin switch for Pulse
Count Selection ( 2 or 4 ).
F
2
4
8. TROUBLE SHOOTING AND MAINTENANCE
PROBLEM
PROBABLE CAUSE
LED does not light.
LED lights even though no
person is within area.
LED lights but signal is not
sent.
REMEDY
Incorrect power supply voltage.
(disconnection, low voltage)
Correct the voltage supply to 9.5 to 16 VDC.
Incorrect detection area.
Incorrect polarity to detector.
LED switch is OFF.
See Section 3.
Switch positive and negative at terminal.
Turn on the Switch. (See Section 5)
Moving object within area. (curtain, wall hanging, etc.)
Remove object from detection area, or change location
of detector.
Rapid temperature changes eithin area.
(heater, air conditioner, etc.)
Remove the source from area, or change location
of detector.
Relay contact is stuck or damaged due to overloading.
Faulty wiring.
Check load of output.
The unit needs repair or replacement.
Wire correctly.
9. SPECIFICATIONS
RX-40QZ
Passive infrared
WIDE : 40 x 40 ft. (12 x 12 m) 85°
WIDE : 78 zones
5 to 8 ft. (1.5 to 2.4 m)
3.6°F (2.0°C) at 2 ft./sec (0.6 m/sec.)
1 to 5 ft./sec (0.3 to 1.5 m/sec.)
Switchable ON/OFF
Approx. 2.5 sec.
N.C., 28 VDC 0.2 A max.
N.C., Open when cover is removed
Approx. 20 sec. 2 or 4
Approx. 30 sec.
9.5 to 16 VDC
8 mA (normal), 11 mA (max.) at 12 VDC
2.5 oz (70 g)
-4°F to +122°F (-20°C to +50°C)
95% max.
No alarm 20 V/m
FL-60N (Optional Lens for Long Range Curtain Pattern)
Coverage
LONG : 60 x 6 ft. (18 x 1.8 m)
Detection zones
LONG : 20 zones
Dimensions
3.82(97)
MODEL
Detection method
Coverage
Detection zones
Mounting height
Sensitivity
Detection speed
LED alarm indicator
Alarm period
Alarm output
Tamper switch
Pulse count
Warm up period
Power input
Current draw
Weight
Operating temperature
Environmental humidity
RF interference
2.44(62)
1.73(44)
Unit : inches (mm)
* Specifications and design are subject to change without prior notice.
Note >>
This unit is designed to detect movement of an intruder
and activate an alarm control panel. Being only a part
of a complete system, we can not accept responsibility
for any damages or other consequences resulting from
an intrusion.
Copyright (C) 2016 OPTEX CO., LTD.
OPTEX CO., LTD. (JAPAN)
URL: http://www.optex.net
OPTEX INC. (U.S.)
URL: http://www.optexamerica.com
OPTEX DO BRASIL LTDA.
(Brazil)
URL: http://www.optex.net/br/es/sec
OPTEX (EUROPE) LTD.
/ EMEA HQ (U.K.)
URL: http://www.optex-europe.com
OPTEX TECHNOLOGIES B.V.
(The Netherlands)
OPTEX PINNACLE INDIA,
PVT., LTD. (India)
OPTEX SECURITY SAS (France)
OPTEX KOREA CO.,LTD. (Korea)
OPTEX SECURITY Sp.z o.o.
(Poland)
OPTEX (DONGGUAN) CO.,LTD.
SHANGHAI OFFICE (China)
URL: http://www.optex.eu
URL: http://www.optex-security.com
URL: http://www.optex.com.pl
URL: http://www.optex.net/in/en/sec
URL: http://www.optexkorea.com
URL: http://www.optexchina.com
Download