Uploaded by Phil Smith

ODIS Service Manual

Offboard Diagnostic Information
System Service User Handbook
Confidential. All rights reserved. Distribution or duplication without prior written consent from Volkswagen AG is prohibited. Contractor receives this document only from the responsible procurement department. VOLKSWAGEN AG Copyright © 2007 VOLKSWAGEN AG Version 4.27.0
Table of Contents
1. Introduction ............................................................................................................................ 14
1.1. Comments about the Handbook ....................................................................................... 14
1.2. Structure of the User Guide ............................................................................................ 15
2. System Requirements ............................................................................................................... 17
3. Installation ............................................................................................................................. 18
4. Update ................................................................................................................................... 36
5. Application start/user interface ................................................................................................... 46
5.1. Operation ..................................................................................................................... 57
5.1.1. Touchscreen ....................................................................................................... 57
5.1.2. Mouse and Keyboard .......................................................................................... 57
5.2. Screenshots for support requests ...................................................................................... 57
5.3. Control module negative response display ......................................................................... 59
6. Diagnosis Operating Mode ........................................................................................................ 62
6.1. Diagnosis Procedure ...................................................................................................... 62
6.2. Diagnostic entrance ....................................................................................................... 63
6.2.1. Start diagnosis .................................................................................................... 64
6.2.2. Vehicle Features Dialog (VFD) ............................................................................. 70
6.2.3. Using the K-line adapter ...................................................................................... 74
6.2.4. Logging in to Group Systems ............................................................................... 75
6.2.4.1. Authentication with SecurID ...................................................................... 76
6.2.4.1.1. Prerequisites ................................................................................. 77
6.2.4.1.2. First registration on the WS gateway ................................................. 78
6.2.4.1.3. Additional messages on the WS gateway ............................................ 80
6.2.5. Select order ....................................................................................................... 81
6.2.6. Control module identification ................................................................................ 88
6.2.6.1. Control module list ................................................................................... 93
6.2.6.2. Network diagram ..................................................................................... 95
6.2.6.3. DTC memory ......................................................................................... 101
6.2.6.4. Equipment list ........................................................................................ 105
6.2.7. Starting Guided Fault Finding (GFF) .................................................................... 107
6.3. Test Plan and Special Functions ..................................................................................... 108
6.3.1. Start Module, Traversal Test, Test Plan Calculation ................................................. 109
6.3.2. DISS / TSB ...................................................................................................... 111
6.3.2.1. Coding assistant ..................................................................................... 119
6.3.3. Special functions ............................................................................................... 120
6.4. Working with GFF ...................................................................................................... 122
6.4.1. Measured values ............................................................................................... 129
6.4.2. Gateway coding ................................................................................................ 131
6.4.3. Documents ....................................................................................................... 136
6.4.4. Test Verification ............................................................................................... 139
6.4.5. Component selection .......................................................................................... 140
6.5. End diagnosis ............................................................................................................. 141
6.6. Quick entrance ............................................................................................................ 148
7. OBD mode ........................................................................................................................... 151
7.1. Start self diagnosis ...................................................................................................... 151
7.2. Self Diagnosis General Information ................................................................................ 153
7.2.1. Starting OBD from other operating modes ............................................................. 153
7.2.2. Accessing OBD functions ................................................................................... 153
7.2.3. Logging ........................................................................................................... 158
7.2.4. Using the keyboard ........................................................................................... 159
7.3. Control Module-Specific Functions ................................................................................. 159
7.3.1. Adaptation ....................................................................................................... 159
7.3.1.1. Control modules with KWP protocol .......................................................... 160
7.3.1.2. Control modules with UDS protocol ........................................................... 163
7.3.2. Code Bus master ............................................................................................... 166
Offboard Diagnostic Information
System Service User Handbook
7.3.2.1. Coding KWP bus masters ........................................................................
7.3.2.2. Coding USD bus masters .........................................................................
7.3.3. Code ...............................................................................................................
7.3.3.1. Coding KWP control modules ...................................................................
7.3.3.2. Coding UDS control modules ...................................................................
7.3.4. DTC memory ...................................................................................................
7.3.5. Basic setting ....................................................................................................
7.3.5.1. KWP control module basic setting .............................................................
7.3.5.2. UDS control module basic setting ..............................................................
7.3.6. Identification ....................................................................................................
7.3.7. Measured values ...............................................................................................
7.3.8. Output diagnostic test mode ................................................................................
7.3.8.1. KWP control module output diagnostic test mode .........................................
7.3.8.2. UDS control module output diagnostic test mode ..........................................
7.3.9. Access authorization ..........................................................................................
7.4. Vehicle-specific functions .............................................................................................
7.4.1. Complete system DTC memory ...........................................................................
7.4.2. Transport mode ................................................................................................
7.4.3. Components list ................................................................................................
7.4.4. OBD ...............................................................................................................
7.5. End self diagnosis .......................................................................................................
8. Flashing Mode ......................................................................................................................
8.1. Start flashing ..............................................................................................................
8.2. Identifying the Vehicle .................................................................................................
8.3. Group Systems Login ...................................................................................................
8.4. Order Selection ...........................................................................................................
8.5. Identifying control modules ...........................................................................................
8.6. Working with Flash Programs ........................................................................................
8.7. Diagnostic objects when flashing ....................................................................................
8.8. End flashing ...............................................................................................................
9. Info mode .............................................................................................................................
9.1. Documents .................................................................................................................
9.1.1. Documents in GFF ............................................................................................
9.2. Campaigns tab ............................................................................................................
9.3. History tab .................................................................................................................
9.4. Manuals tab ................................................................................................................
9.5. Wiring diagrams tab ....................................................................................................
9.6. Vehicle tab .................................................................................................................
9.7. PR no. tab ..................................................................................................................
10. Virtual Keyboard User Guide ................................................................................................
10.1. Installation ................................................................................................................
10.2. Software ...................................................................................................................
10.2.1. User interface .................................................................................................
10.2.1.1. Keyboard Size ......................................................................................
10.2.1.2. Special Function Keys ...........................................................................
10.2.1.3. Settings Dialog .....................................................................................
10.2.2. Languages ......................................................................................................
10.2.3. Keyboard Layouts ...........................................................................................
10.2.3.1. German ...............................................................................................
10.2.3.2. Bulgarian .............................................................................................
10.2.3.3. Chinese simplified .................................................................................
10.2.3.4. Danish ................................................................................................
10.2.3.5. English GB ..........................................................................................
10.2.3.6. English USA ........................................................................................
10.2.3.7. Farsi ...................................................................................................
10.2.3.8. Finnish ................................................................................................
10.2.3.9. French ................................................................................................
10.2.3.10. Greek ................................................................................................
167
169
171
172
174
180
183
183
185
191
193
196
196
199
205
210
210
212
213
214
218
220
221
223
225
227
229
230
231
232
234
235
242
244
245
246
247
248
250
251
251
251
251
252
253
253
253
254
254
255
255
256
256
257
258
258
259
260
Offboard Diagnostic Information
System Service User Handbook
10.2.3.11. Italian ................................................................................................
10.2.3.12. Japanese ............................................................................................
10.2.3.12.1. Direct input .............................................................................
10.2.3.12.2. Hiragana .................................................................................
10.2.3.12.3. Katakana .................................................................................
10.2.3.13. Korean ..............................................................................................
10.2.3.13.1. English ...................................................................................
10.2.3.13.2. Hangul ....................................................................................
10.2.3.14. Croatian .............................................................................................
10.2.3.15. Dutch ................................................................................................
10.2.3.16. Polish ................................................................................................
10.2.3.17. Portuguese .........................................................................................
10.2.3.18. Romanian ..........................................................................................
10.2.3.19. Russian ..............................................................................................
10.2.3.20. Swedish .............................................................................................
10.2.3.21. Slovakian ...........................................................................................
10.2.3.22. Slovenian ...........................................................................................
10.2.3.23. Spanish ..............................................................................................
10.2.3.24. Taiwan (Bopomofo) .............................................................................
10.2.3.25. Taiwan (ChaJei) ..................................................................................
10.2.3.26. Thai ..................................................................................................
10.2.3.27. Czech ................................................................................................
10.2.3.28. Turkish ..............................................................................................
10.2.3.29. Hungarian ..........................................................................................
11. Administration Mode ............................................................................................................
11.1. Operation .................................................................................................................
11.2. General Area .............................................................................................................
11.3. Save Locations Area ..................................................................................................
11.4. Support Area .............................................................................................................
11.5. Connections Area .......................................................................................................
11.6. Certificates field ........................................................................................................
11.7. Test baseline area ......................................................................................................
12. Additional Program Functions ................................................................................................
12.1. Log .........................................................................................................................
12.1.1. General ..........................................................................................................
12.1.2. Diagnostic log ................................................................................................
12.1.3. Self diagnostic protocol ....................................................................................
12.2. Data ........................................................................................................................
12.2.1. Current view ..................................................................................................
12.2.2. Diagnostic session ...........................................................................................
12.2.2.1. Repair interruption ................................................................................
12.2.2.2. Performing a repair ...............................................................................
12.2.3. Hotfix ...........................................................................................................
12.3. Extras ......................................................................................................................
12.3.1. Search ...........................................................................................................
12.3.2. Diagnostic interface .........................................................................................
12.3.3. Road test .......................................................................................................
12.3.4. Update ...........................................................................................................
12.3.5. Connection test ...............................................................................................
12.4. Help ........................................................................................................................
12.4.1. Online help ....................................................................................................
12.4.2. Support ..........................................................................................................
12.5. Info .........................................................................................................................
13. Error Messages ....................................................................................................................
13.1. Error IDs ..................................................................................................................
13.2. Additional error messages ...........................................................................................
13.2.1. Firewall messages ............................................................................................
13.2.2. Browser messages ...........................................................................................
261
262
262
262
263
263
263
264
264
265
266
267
267
268
269
269
270
271
272
272
273
274
274
275
277
277
280
294
300
305
315
322
324
324
325
326
327
328
330
330
331
333
335
341
342
344
347
349
350
352
352
356
362
367
368
382
382
383
Offboard Diagnostic Information
System Service User Handbook
14. Index .................................................................................................................................. 384
Glossary ................................................................................................................................... 389
List of Figures
1.1. Example of the Diagnosis Procedure ........................................................................................
1.2. Example of a Section of a Procedure with Individual Steps ...........................................................
1.3. Example of an Active Link in the Table of Contents ...................................................................
3.1. Starting the Installation ..........................................................................................................
3.2. Installation Language Selection ...............................................................................................
3.3. The Offboard Diagnostic Information System Service Setup Assistant .............................................
3.4. Destination Folder for the Installation .......................................................................................
3.5. Diagnostic Components Destination Directory ............................................................................
3.6. Platform selection .................................................................................................................
3.7. Application Language Selection ...............................................................................................
3.8. Diagnostic interface selection ..................................................................................................
3.9. Note about the Bluetooth Interface ...........................................................................................
3.10. Certificate selection .............................................................................................................
3.11. Start menu folder selection ....................................................................................................
3.12. Copying process display .......................................................................................................
3.13. PDU API Installation ...........................................................................................................
3.14. MCD Server Installation .......................................................................................................
3.15. Completed installation ..........................................................................................................
3.16. PostSetup start ....................................................................................................................
3.17. PostSetup data display ..........................................................................................................
3.18. PostSetup files installation ....................................................................................................
3.19. Internet Options for Internet Explorer 6 ...................................................................................
4.1. Pause download ....................................................................................................................
4.2. Updates ready for installation ..................................................................................................
4.3. Checking for updates .............................................................................................................
4.4. No Updates Available ............................................................................................................
4.5. Available updates ..................................................................................................................
4.6. Missing update files ..............................................................................................................
4.7. Warning before updating ........................................................................................................
4.8. Updating using the network ....................................................................................................
4.9. Error message when site.xml is missing ....................................................................................
4.10. Establishing a Connection to the Update Site ............................................................................
4.11. Warning when there is insufficient disk space ...........................................................................
4.12. Available Updates Display ....................................................................................................
4.13. No Updates Available ..........................................................................................................
4.14. Update progress indicator ......................................................................................................
4.15. Error when performing an update ...........................................................................................
5.1. Starting Offboard Diagnostic Information System Service .............................................................
5.2. Message stating the license will soon expire ..............................................................................
5.3. Logging into the group systems for extending a license ................................................................
5.4. Success message when the license has been extended ..................................................................
5.5. Error message when extending the license .................................................................................
5.6. Windows with warnings/notes (part 1) ......................................................................................
5.7. Windows with warnings/notes (part 2) ......................................................................................
5.8. Message regarding transmission of the diagnostic log ..................................................................
5.9. Offboard Diagnostic Information System Service User Interface ....................................................
5.10. The Info area ......................................................................................................................
5.11. Operating Modes Menu ........................................................................................................
5.12. Standard Functions Menus ....................................................................................................
5.13. Log submenu ......................................................................................................................
5.14. Data submenu .....................................................................................................................
5.15. Extras Submenu ..................................................................................................................
5.16. Help Submenu ....................................................................................................................
5.17. Info Submenu .....................................................................................................................
5.18. Status Area - Sample Test Plan Calculation ..............................................................................
14
15
15
19
19
20
21
22
23
23
24
25
26
27
28
29
29
30
31
32
33
34
36
37
37
38
38
39
40
40
41
41
42
42
43
43
44
46
46
46
47
47
48
48
49
50
50
52
53
54
55
55
56
56
56
Offboard Diagnostic Information
System Service User Handbook
5.19. Making a screenshot ............................................................................................................ 58
5.20. Support request with a screenshot ........................................................................................... 58
5.21. Note from the control module with Negative Response Code ....................................................... 59
6.1. Diagnostic Entry Process ........................................................................................................ 62
6.2. Diagnostic Entry Section ........................................................................................................ 63
6.3. Start Diagnosis Section .......................................................................................................... 64
6.4. Entry Window after Starting the Application .............................................................................. 64
6.5. Unpermitted Bluetooth Connection ........................................................................................... 65
6.6. Diagnostic entrance start window ............................................................................................. 66
6.7. No vehicle connected ............................................................................................................. 67
6.8. No vehicle connected ............................................................................................................. 67
6.9. Vehicle recognition not possible .............................................................................................. 68
6.10. Ignition is switched off ......................................................................................................... 68
6.11. Ignition status not recognized ................................................................................................ 69
6.12. Status Area - Example of Determining a VIN ........................................................................... 69
6.13. Performing the Vehicle Features Dialog Section ........................................................................ 70
6.14. Dialog for selecting vehicle features ....................................................................................... 70
6.15. Guided Fault Finding inquiry ................................................................................................. 71
6.16. Error during automatic identification ....................................................................................... 71
6.17. Entering the VIN Manually ................................................................................................... 72
6.18. Using the K-line adapter ...................................................................................................... 74
6.19. Logging in to Group Systems Section ..................................................................................... 75
6.20. Group Systems Login Window .............................................................................................. 75
6.21. SecurID card ...................................................................................................................... 76
6.22. Create PIN ......................................................................................................................... 78
6.23. Assign PIN ......................................................................................................................... 78
6.24. Check the PIN and confirm it with the token ............................................................................ 79
6.25. PIN created successfully ....................................................................................................... 79
6.26. Password input screen .......................................................................................................... 80
6.27. Work order selection section - diagnostic entrance ..................................................................... 81
6.28. Work order selection section - Flash entrance ........................................................................... 81
6.29. Order View during Diagnostic Entry ....................................................................................... 82
6.30. Login to Group Systems Not Possible ..................................................................................... 83
6.31. Order list view .................................................................................................................... 84
6.32. Order detail view ................................................................................................................ 85
6.33. No DISS concerns ............................................................................................................... 86
6.34. Entering the order number .................................................................................................... 86
6.35. "Work without order" selection .............................................................................................. 87
6.36. Identifying Control Modules Section ....................................................................................... 88
6.37. Gateway control module malfunction in communication ............................................................. 88
6.38. Communication malfunction Gateway control module with communication test ............................... 89
6.39. "Check components list" dialog .............................................................................................. 90
6.40. Editing the coding status ....................................................................................................... 91
6.41. "Unrecognized control modules" dialog ................................................................................... 92
6.42. "Working with base version" dialog ........................................................................................ 92
6.43. Control module list view ...................................................................................................... 93
6.44. Control module information .................................................................................................. 94
6.45. Sorting the Control Module List ............................................................................................. 94
6.46. Networking diagram view ..................................................................................................... 95
6.47. Examples of Control Module Graphic Display .......................................................................... 97
6.48. Buttons for Individual Control Modules ................................................................................... 97
6.49. Context Menu (Control Module Buttons) ................................................................................. 98
6.50. Entering a Control Module as Installed .................................................................................... 98
6.51. Italic display of control modules manually entered "as installed" .................................................. 99
6.52. "Select version" Dialog ........................................................................................................ 99
6.53. Selecting control module guided functions .............................................................................. 100
6.54. DTC memory entries view .................................................................................................. 101
6.55. Opening a DTC memory entry ............................................................................................. 102
Offboard Diagnostic Information
System Service User Handbook
6.56. Information about a DTC memory entry ................................................................................
6.57. Sorting DTC List ...............................................................................................................
6.58. Context menu in the DTC memory view ................................................................................
6.59. Equipment list view ...........................................................................................................
6.60. Equipment list context menu ................................................................................................
6.61. Select version ....................................................................................................................
6.62. Starting GFF Section ..........................................................................................................
6.63. Starting Guided Fault Finding ..............................................................................................
6.64. Test Plan and Special Functions Section ................................................................................
6.65. Start Module, Traversal Test, Test Plan Calculation Section .......................................................
6.66. Version Selection View ......................................................................................................
6.67. DISS / TSB Section ...........................................................................................................
6.68. View inside the DISS tab after the diagnostic entrance .............................................................
6.69. Table with DISS Concerns ..................................................................................................
6.70. Coding assistance dialog window .........................................................................................
6.71. Function buttons in the DISS tab ..........................................................................................
6.72. TSB tab view ...................................................................................................................
6.73. Showing a Selected TSB Number .........................................................................................
6.74. Entering a TSB Manually ....................................................................................................
6.75. Transfer diagnostic object to test plan ....................................................................................
6.76. Deselected Customer Code ..................................................................................................
6.77. Selecting the Complete View ...............................................................................................
6.78. Complete View of a Customer Code .....................................................................................
6.79. Coding assistant ................................................................................................................
6.80. Special Functions View ......................................................................................................
6.81. Working with GFF Section ..................................................................................................
6.82. Test Plan View ..................................................................................................................
6.83. Activating a test in the test plan ...........................................................................................
6.84. Test view in the Operation tab .............................................................................................
6.85. Message and Instruction Window in the Test Procedure ............................................................
6.86. Sequence of Steps in the Test Procedure ................................................................................
6.87. Screen Buttons to Select Alternate Test Steps .........................................................................
6.88. Display of Selected Test Steps .............................................................................................
6.89. Decision screen buttons in the test program ............................................................................
6.90. Measurement selection ........................................................................................................
6.91. Measurements display .........................................................................................................
6.92. Description of a measurement ..............................................................................................
6.93. Selection of control module to be coded ................................................................................
6.94. Display of the coded/not coded control modules in the test program ............................................
6.95. Special coding - brand selection ...........................................................................................
6.96. Inquiry before writing the Gateway coding .............................................................................
6.97. Inquiry with changed coding ................................................................................................
6.98. Function descriptions in the test program ...............................................................................
6.99. Local and Global Documents in the Test Program ...................................................................
6.100. Leaving Document View ...................................................................................................
6.101. Verification mode inquiry ..................................................................................................
6.102. Test selection window .......................................................................................................
6.103. End Diagnosis Section ......................................................................................................
6.104. End diagnosis ..................................................................................................................
6.105. Ending fault finding ..........................................................................................................
6.106. Erasing the DTC memory ..................................................................................................
6.107. Erasing the DTC memory ..................................................................................................
6.108. Performing the readiness code program ................................................................................
6.109. Send diagnostic log? .........................................................................................................
6.110. Print/save diagnostic log ....................................................................................................
6.111. Select diagnostic log .........................................................................................................
6.112. Support request ................................................................................................................
6.113. Manual control module selection .........................................................................................
102
103
104
105
106
106
107
107
108
109
109
111
111
112
113
114
115
115
116
116
117
118
118
119
121
122
123
124
125
126
127
128
128
129
129
130
131
132
133
133
134
135
136
137
138
139
140
141
142
142
143
143
144
145
145
146
147
148
Offboard Diagnostic Information
System Service User Handbook
6.114. Quick entrance test plan ....................................................................................................
6.115. Print/save diagnostic log ....................................................................................................
7.1. OBD entry start window .......................................................................................................
7.2. Starting OBD ......................................................................................................................
7.3. Control Module Self Diagnosis Selection Window .....................................................................
7.4. Vehicle Self Diagnosis Selection Window ................................................................................
7.5. OBD control module window during diagnostic entrance ............................................................
7.6. Vehicle OBD window during diagnostic entrance ......................................................................
7.7. Self Diagnosis: Sample Tab Name ..........................................................................................
7.8. Warning about adaptation that is not supported .........................................................................
7.9. Selection of function versions ................................................................................................
7.10. KWP Adaptation ...............................................................................................................
7.11. Resetting the adaptation ......................................................................................................
7.12. UDS Adaptation ................................................................................................................
7.13. Warning when closing the parameter list ................................................................................
7.14. Security prompt before performing the adaptation ....................................................................
7.15. Error message about invalid adaptation value ..........................................................................
7.16. Error message for control modules that are not bus masters .......................................................
7.17. Coding KWP bus masters ...................................................................................................
7.18. Prompt before coding .........................................................................................................
7.19. Progress bar during coding ..................................................................................................
7.20. Error when coding (example) ...............................................................................................
7.21. Edit special code ...............................................................................................................
7.22. Coding USD bus masters ....................................................................................................
7.23. Prompt before automatic coding ...........................................................................................
7.24. Progress bar during coding ..................................................................................................
7.25. Error when coding (example) ...............................................................................................
7.26. Short Coding .....................................................................................................................
7.27. Security prompt before coding .............................................................................................
7.28. Confirmation message after coding .......................................................................................
7.29. Prompt to reset the ignition .................................................................................................
7.30. New and old code ..............................................................................................................
7.31. Error message when coding due to incorrect data .....................................................................
7.32. Binary coding ...................................................................................................................
7.33. User input with binary coding ..............................................................................................
7.34. Security prompt before binary coding ....................................................................................
7.35. Note about missing check sum for binary code ........................................................................
7.36. Note about incorrect check sum for binary code ......................................................................
7.37. Confirmation message after coding .......................................................................................
7.38. Prompt to reset the ignition .................................................................................................
7.39. Warning when changing to plain text coding ..........................................................................
7.40. UDS Plain Text Coding ......................................................................................................
7.41. KWP DTC memory ...........................................................................................................
7.42. Sorting the DTC memory entries ..........................................................................................
7.43. UDS DTC Memory ............................................................................................................
7.44. Selection of function versions ..............................................................................................
7.45. KWP Basic Setting ............................................................................................................
7.46. UDS Basic Setting - Basic Setting Selection ...........................................................................
7.47. UDS Basic Setting - Setting Parameters .................................................................................
7.48. UDS Basic Setting - Measured Value Selection .......................................................................
7.49. UDS Basic Setting - Performing ...........................................................................................
7.50. Results window for OBD identification ..................................................................................
7.51. Measured Value Selection ...................................................................................................
7.52. KWP - Measured value display ............................................................................................
7.53. Selection of function versions ..............................................................................................
7.54. KWP Output Diagnostic Test Mode ......................................................................................
7.55. Output Diagnostic Test Mode Status .....................................................................................
7.56. UDS actuator selection .......................................................................................................
149
149
151
153
154
155
156
156
158
158
160
160
162
163
164
165
165
166
167
167
168
168
168
169
169
170
170
172
173
173
173
173
174
175
176
176
177
177
177
178
178
179
180
181
182
183
184
186
187
188
189
191
193
195
196
197
198
199
Offboard Diagnostic Information
System Service User Handbook
7.57. Setting UDS Actuator Parameters .........................................................................................
7.58. UDS output diagnostic test mode - problems with wetting parameters ..........................................
7.59. UDS Measured Value Selection ...........................................................................................
7.60. UDS Output Diagnostic Test Mode .......................................................................................
7.61. Example of an actuator test on several actuators ......................................................................
7.62. Access authorization ...........................................................................................................
7.63. Access authorization - successful ..........................................................................................
7.64. Access authorization - unsuccessful .......................................................................................
7.65. Complete system DTC memory ............................................................................................
7.66. Selecting the method of erasing the DTC memory ...................................................................
7.67. Warning message before erasing the DTC memory ..................................................................
7.68. Transport mode .................................................................................................................
7.69. Message indicating the switch to transport mode was successful .................................................
7.70. Transport mode .................................................................................................................
7.71. Components list .................................................................................................................
7.72. Display when there is faulty communication with a control module .............................................
7.73. The OBD function is selected ..............................................................................................
7.74. The OBD parameter is selected ............................................................................................
7.75. OBD result display ............................................................................................................
7.76. Ending the Flash Session ....................................................................................................
7.77. End self diagnosis ..............................................................................................................
7.78. Saving the OBD log ...........................................................................................................
8.1. Work Process in Flashing Mode .............................................................................................
8.2. Starting Flashing Section ......................................................................................................
8.3. Flash entry start window .......................................................................................................
8.4. Identifying the Vehicle Section ..............................................................................................
8.5. Vehicle Analysis during Flash Entry .......................................................................................
8.6. Manual vehicle identification .................................................................................................
8.7. Automatic Vehicle Identification ............................................................................................
8.8. Logging in to Group Systems Section .....................................................................................
8.9. Group Systems Login Window ..............................................................................................
8.10. Selecting an Order Section ..................................................................................................
8.11. Selecting an Order for Flashing ............................................................................................
8.12. Identifying Control Modules Section .....................................................................................
8.13. Control Module Identification ..............................................................................................
8.14. Running Flash Programs Section ..........................................................................................
8.15. Available Flash Programs ....................................................................................................
8.16. Basic features manual selection ............................................................................................
8.17. Manual control module selection ..........................................................................................
8.18. Ending Flashing Section ......................................................................................................
8.19. Ending the Flash Session ....................................................................................................
8.20. Ending the Flash Session ....................................................................................................
9.1. Tabs in Information mode .....................................................................................................
9.2. Information Mode Entry View ...............................................................................................
9.3. Selecting a document to display .............................................................................................
9.4. Viewing a document ............................................................................................................
9.5. Example 1, document tree .....................................................................................................
9.6. Example 1, document view ...................................................................................................
9.7. Example 2, document tree .....................................................................................................
9.8. Example 2, document view ...................................................................................................
9.9. Document with Hot Spot ......................................................................................................
9.10. Open Hot Spot ..................................................................................................................
9.11. Displaying documents for a test plan .....................................................................................
9.12. Campaigns tab view ...........................................................................................................
9.13. History tab view ................................................................................................................
9.14. Manuals tab view ..............................................................................................................
9.15. Wiring diagrams view ........................................................................................................
9.16. Vehicle view .....................................................................................................................
200
201
202
203
204
206
208
209
210
211
211
212
212
213
213
214
215
216
217
218
218
219
220
221
222
223
223
224
225
225
226
227
228
229
229
230
230
231
232
232
233
233
234
235
236
237
238
239
239
240
240
241
242
244
245
246
247
249
Offboard Diagnostic Information
System Service User Handbook
9.17. PR no. view ......................................................................................................................
10.1. Toolbar symbol .................................................................................................................
10.2. Keyboard Layout ...............................................................................................................
10.3. Numerical Keyboard ..........................................................................................................
10.4. Settings Dialog ..................................................................................................................
11.1. Administration window .......................................................................................................
11.2. Selecting the Design ...........................................................................................................
11.3. Language setting ................................................................................................................
11.4. Additional Windows language support ...................................................................................
11.5. Windows language display codes ..........................................................................................
11.6. Update view .....................................................................................................................
11.7. Configuration error when checking for updates .......................................................................
11.8. System configuration view ..................................................................................................
11.9. System environment view ...................................................................................................
11.10. License Information Part 1 View ........................................................................................
11.11. License Information Part 2 View ........................................................................................
11.12. Global configuration view .................................................................................................
11.13. GFF procedure details view ...............................................................................................
11.14. Virtual Keyboard Detailed View .........................................................................................
11.15. View of the dealer data details ...........................................................................................
11.16. Database Directory ...........................................................................................................
11.17. Diagnostic Session Save Location .......................................................................................
11.18. Flash paths view ..............................................................................................................
11.19. Diagnostic log view ..........................................................................................................
11.20. Support view ...................................................................................................................
11.21. E-mail Outbox Server View ...............................................................................................
11.22. Error message about an incorrect mail server ........................................................................
11.23. Error message about an incorrect sender address ....................................................................
11.24. Brand Settings View .........................................................................................................
11.25. Group system view: Logon ................................................................................................
11.26. Group System: GFF ..........................................................................................................
11.27. Group system ElsaPro view ...............................................................................................
11.28. Carport View ...................................................................................................................
11.29. DISS View .....................................................................................................................
11.30. Group system eShop view .................................................................................................
11.31. Mirror server 2 view .........................................................................................................
11.32. Client certificates view ......................................................................................................
11.33. The hardware ID in the client certificate is incorrect ...............................................................
11.34. The validity period has expired. ..........................................................................................
11.35. The format is not supported. ..............................................................................................
11.36. Client certificate detail view ...............................................................................................
11.37. Trust certificate view ........................................................................................................
11.38. The validity period has expired. ..........................................................................................
11.39. The format is not supported. ..............................................................................................
11.40. Trust certificate detailed view .............................................................................................
11.41. Data configuration view ....................................................................................................
12.1. Screen button log ...............................................................................................................
12.2. Selecting the diagnostic log .................................................................................................
12.3. Maximum number of values exceeded ...................................................................................
12.4. Data button .......................................................................................................................
12.5. Query when canceling a diagnostic session .............................................................................
12.6. Saving a diagnostic session .................................................................................................
12.7. Feedback after Saving a Diagnostic Session ............................................................................
12.8. Loading a diagnostic session file ..........................................................................................
12.9. Error when loading a diagnostic session .................................................................................
12.10. Login when loading a diagnostic session ..............................................................................
12.11. Selecting the hot fix directory ............................................................................................
12.12. Error while loading the hot fix ...........................................................................................
250
251
252
252
253
277
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
297
298
300
302
304
304
305
306
307
309
311
312
313
314
316
317
317
317
318
319
320
320
321
322
324
325
327
329
331
331
332
333
334
334
335
336
Offboard Diagnostic Information
System Service User Handbook
12.13. Copying the hot fix ..........................................................................................................
12.14. Installing the hot fix .........................................................................................................
12.15. Error while installing the hot fix .........................................................................................
12.16. Hot fix installation successful .............................................................................................
12.17. Hot fix deleted successfully ...............................................................................................
12.18. Loading test baseline ........................................................................................................
12.19. Confirming test baseline loading .........................................................................................
12.20. Loading in the background ................................................................................................
12.21. Loading the test baseline ...................................................................................................
12.22. Cancellation by user when loading the test baseline ................................................................
12.23. Error when loading the test baseline ....................................................................................
12.24. Successful test baseline loading ..........................................................................................
12.25. Updating the test baseline ..................................................................................................
12.26. Sending a diagnostic log with test baseline ...........................................................................
12.27. Extras Menu Content ........................................................................................................
12.28. Search function form ........................................................................................................
12.29. Search function results display ...........................................................................................
12.30. Search result example .......................................................................................................
12.31. Current diagnostic interface display .....................................................................................
12.32. Changing the diagnostic interface ........................................................................................
12.33. Detail information regarding the current diagnostic interface ....................................................
12.34. Activating the road test mode .............................................................................................
12.35. Confirming the activated road test mode ..............................................................................
12.36. End road test mode ..........................................................................................................
12.37. Confirming the cancelled road test mode ..............................................................................
12.38. Confirming the ended road test mode ..................................................................................
12.39. Notes when starting a manual update ...................................................................................
12.40. Selecting a brand for the connection test ..............................................................................
12.41. Connection test configuration .............................................................................................
12.42. Connection test is being performed ......................................................................................
12.43. Help menu ......................................................................................................................
12.44. Context-Based Online Help ................................................................................................
12.45. The Online Help window ..................................................................................................
12.46. Navigation in Online Help .................................................................................................
12.47. Online Help Navigation Bar ...............................................................................................
12.48. Save support request .........................................................................................................
12.49. Send support inquiry .........................................................................................................
12.50. Information about feedback sender ......................................................................................
12.51. Error classification feedback ..............................................................................................
12.52. Error priority feedback ......................................................................................................
12.53. Additional attachments ......................................................................................................
12.54. Logging into the mail server for feedback .............................................................................
12.55. Incorrect login to mail server .............................................................................................
12.56. Feedback message with an offline connection ........................................................................
12.57. Windows with warnings/notes (part 1) .................................................................................
12.58. Windows with warnings/notes (part 2) .................................................................................
12.59. Windows with warnings/notes (part 3) .................................................................................
12.60. Information Area ..............................................................................................................
13.1. Error message explanations .................................................................................................
13.2. Windows firewall message ..................................................................................................
13.3. Browser security warning ....................................................................................................
336
336
336
337
337
338
338
338
339
339
339
340
340
340
341
342
343
343
345
345
346
347
347
348
348
348
349
350
351
352
352
353
354
355
355
356
357
358
358
359
359
360
360
361
363
364
365
366
367
382
383
List of Tables
5.1. Table 1: Negative Response Code (NRC) from control module at KWP 2000 ................................... 59
5.2. Table 2: negative response from the control module at KWP 1281 ................................................. 61
6.1. Meaning of the SCP Status Numbers ........................................................................................ 82
7.1. Control Module Self Diagnosis View Names ............................................................................ 157
7.2. Vehicle Self Diagnosis View Names ....................................................................................... 157
7.3. Keyboard shortcuts table ....................................................................................................... 159
8.1. Meaning of the SCP Status Numbers ...................................................................................... 228
10.1. Installation Parameters ........................................................................................................ 251
10.2. Install Return Values .......................................................................................................... 251
10.3. I+ME Buttons ................................................................................................................... 252
10.4. Changing Characters .......................................................................................................... 253
10.5. Supported Languages .......................................................................................................... 254
13.1. Error ID Table .................................................................................................................. 368
Chapter 1. Introduction
1.1. Comments about the Handbook
This handbook describes how to use the Offboard Diagnostic Information System Service program from the
Volkswagen Group. The program is used during workshop diagnosis and can identify vehicle control modules,
read DTC memory entries and assist with vehicle repairs through Guided Fault Finding. Functions such as measurement support, flashing control modules and vehicle self-diagnosis expand the range of application. All important information and services from the Volkswagen Group are available while working via a network connection
to the group systems.
Offboard Diagnostic Information System Service is designed for all brands in the Volkswagen group.
To visualize the important procedures such as diagnosis and flashing, the chapters on these topics contain illustrations that show exactly which portion of the procedure is being described, what the previous step was and what
will be done next.
Figure 1.1. Example of the Diagnosis Procedure
In the example shown above, the entire diagnosis procedure is presented. The diagnosis procedure is divided into
four sections with each section containing the individual steps. The section that is currently being described is
shown in red.
The description of the individual sections with the individual steps appears as shown below:
14
Introduction
Figure 1.2. Example of a Section of a Procedure with Individual Steps
This example shows the individual steps in their logical, chronological order. The step that is currently being
described is shown in red.
Notice:
This manual should be read completely before using Offboard Diagnostic Information System Service for the
first time. The warnings and notes regarding working with Offboard Diagnostic Information System Service
and the vehicle during diagnostic and repair procedures must be followed exactly.
Currentness of illustrations: All illustrations are up-to-date, even if they have an older version number.
1.2. Structure of the User Guide
Using the in the PDF document is recommended in order to access the information needed quickly. If the manual is
available in electronic form, you can click directly on the desired topic in the table of contents to go to the chapter.
Figure 1.3. Example of an Active Link in the Table of Contents
The blue pushpin is generally used for bullet points or to structure the procedures within the system.
Notice:
The red pushpin with the word Notice: and a frame (for black and white printouts) indicates especially important
notes that must be followed.
Note:
This symbol is used for supplementary information and useful tips.
Font types:
15
Introduction
All system components such as menus, interfaces, buttons, keyboards or touchscreen are written in bold font.
This makes it easier to search within the manual and in Offboard Diagnostic Information System Service. File
names or paths are shown in italic font.
Example: "The vehicle basic features must be selected after clicking the Start diagnosis button. The Vehicle
features form appears."
Cross-reference:
You can switch to related topics quickly using the cross-references in this user guide. These are also linked in
electronic form.
Note:
The following chapter, "Name of Chapter", contains additional information.
16
Chapter 2. System Requirements
The following conditions must be met to use Offboard Diagnostic Information System Service:
Hardware Requirements
PCMCIA slot with EDIC card or Bluetooth using VAS5054 or USB cable to VAS5054
PT boxes and VAS 5055
CPU 1GHz or higher recommended
RAM > 512 MB
Hard drive > 10 GB
Supported tester hardware
VAS5051B
VAS5052A
VAS6150
VAS6150A
VAS6150B
VAS6160
Software Requirements
Windows XP / SP3 or Windows 2000
Java Runtime Environment 1.5.0_11
Libraries (DLL) for Microsoft Visual Studio 2005, vcredist_x86.exe (contained in Windows XP / SP3)
Notice:
The installed libraries for Microsoft Visual Studio 2005 are usually located in the c:\Windows\WinSxS directory
and begin with x86_Microsoft_VC80_CRT*. Without these files, a tester cannot generate a hardware key, and
without that, a license cannot be purchased for the device in the Offboard Diagnostic Information System
eShop.
The local administrator must be informed if the required files are not available.
17
Chapter 3. Installation
This chapter covers the Offboard Diagnostic Information System Service installation procedure.
Notice:
If an older version of Offboard Diagnostic Information System Service is already installed on the device, the
older version must be removed before you can start installing the current Offboard Diagnostic Information
System Service.
Administrator rights for the operating system on the tester or laptop are required to install, remove and configure
Offboard Diagnostic Information System Service.
There are two installation options.
The first option is online installation:
Open the e-mail received from the eShop.
Save the license certificate contained in the e-mail in any directory.
Click the URL in the e-mail to reach the versions of the installation file (setup.exe) on the Mirrorserver 2.
Save setup.exe in any directory.
DVD with a double click on the stored setup.exe starts the installation assistant.
The second option is an offline installation:
Save the license certificate contained in the e-mail in any directory.
Insert the DVD with the installation data into the drive.
Once the DVD starts, select the version that was ordered.
Click the correct setup.exe to start the installation wizard.
Notice:
With the offline installation, it is important to install the version of Offboard Diagnostic Information System
Service that was ordered. If the setup.exe file for a different version is installed, it will not be possible to start
the application because the license will not match.
The installation wizard starts.
18
Installation
Figure 3.1. Starting the Installation
Cancel: you can cancel the Offboard Diagnostic Information System Service installation by clicking on this
button.
The preferred language must be selected for the installation.
Figure 3.2. Installation Language Selection
When selecting a language, click the List field to select the desired language for Offboard Diagnostic Information System Service. German is displayed as the default language.
OK: The selection is confirmed.
Cancel: The installation is cancelled.
After selecting the language, a message appears instructing you to close all open programs.
19
Installation
Figure 3.3. The Offboard Diagnostic Information System Service Setup Assistant
Continue: The Offboard Diagnostic Information System Service installation continues.
Cancel: The installation is cancelled.
Notice:
Open programs must be closed before installing Offboard Diagnostic Information System Service to ensure
it is installed correctly.
The destination folder for the installation must then be specified.
20
Installation
Figure 3.4. Destination Folder for the Installation
The default destination folder is C:\Programs\Offboard_Diagnostic_Information_System_Service
The path may differ if the operating system is in another language.
For example, C:\Program Files\Offboard_Diagnostic_Information_System_Service
Back: The installation goes back one step.
Continue: The Offboard Diagnostic Information System Service installation continues.
Cancel: The installation is cancelled.
The destination directory for the diagnostic components (MCD server, MCD projects and PDU-API) must
now be specified.
21
Installation
Figure 3.5. Diagnostic Components Destination Directory
The default directory is C:\ODIS-DIAG-MODULES.
Back: The installation goes back one step.
Continue: The Offboard Diagnostic Information System Service installation continues.
Cancel: The installation is cancelled.
Using the list field Target platform, you must select the device on which Offboard Diagnostic Information
System Service will be installed.
22
Installation
Figure 3.6. Platform selection
With diagnostic systems, select the system type. Always select Standard PC/notebook for PCs or notebooks.
Back: The installation goes back one step.
Continue: The Offboard Diagnostic Information System Service installation continues.
Cancel: The installation is cancelled.
Select the application's supported language using the Application language selection list field.
Figure 3.7. Application Language Selection
23
Installation
Up to five languages may be selected.
Back: The installation goes back one step.
Continue: The Offboard Diagnostic Information System Service installation continues.
Cancel: The installation is cancelled.
Select the desired diagnostic interface using the Diagnostic interface list field.
Figure 3.8. Diagnostic interface selection
Back: The installation goes back one step.
Continue: The Offboard Diagnostic Information System Service installation continues.
Cancel: The installation is cancelled.
24
Installation
Notice:
Offboard Diagnostic Information System Service is prepared for using the . The following models can be used
by Offboard Diagnostic Information System Service with not restrictions :
•
Blue Streak Electronics Inc. - iflash Global Programmer
•
Dearborn Group - VSI-2534
•
Drew Technologies - CarDAQ-Plus
•
I+ME Actia GmbH - PassThru+ XS
The PassThru boxes listed are already set up in Offboard Diagnostic Information System as diagnostic interfaces.
To use, the box simply needs to be connected to the diagnostic tester via a USB connection and the corresponding
software package needs to be installed from the Offboard Diagnostic Information System Service - Installation
folder (sub-directory "drivers") .
If a Bluetooth interface was selected, a message appears informing you that a Bluetooth pairing must be established according to the remote diagnosis head documentation in order to use the VAS5054.
Figure 3.9. Note about the Bluetooth Interface
Back: The installation goes back one step.
Continue: The Offboard Diagnostic Information System Service installation continues.
Cancel: The installation is cancelled.
25
Installation
Notice:
To install and use a remote diagnosis head, please refer to the version 1.11 of the document Remote Diagnosis
Head VAS 5054A and Diagnostic Interface VAS 5055, Installation and Operation on VAS 5052A from Base CD
16 and Higher and VAS 6150 from Base CD 15 and higher.
A valid certification is assigned to the Offboard Diagnostic Information System Service in the selection of
the file with the certificate. The certificate is available in the form of a license.dat file.
Figure 3.10. Certificate selection
Search: you can search for the location of the license.dat file in the Windows file directory.
An example of the location of the certificate is:
C:\Licenses\license.dat
Click the license.dat certificate file to automatically transfer the file location into the input field.
Copy the certificate to the installation folder If the checkbox is checked off, the certificate will be copied into
the standard installation folder. If the checkbox is not checked off, the Offboard Diagnostic Information System
Service will be installed without a certificate file. The certificate must then be installed separately before starting
the system for the first time.
The standard installation folder for the license file is:
C:\Program Files\Offboard_Diagnostic_Information_System_Service\license\license.dat
Back: The installation goes back one step.
Continue: The Offboard Diagnostic Information System Service installation continues.
26
Installation
Cancel: The installation is cancelled.
The name of the Start menu folder can be selected after that. The "Offboard Diagnostic Information System
Service" is used as the default. Or you can deselect the checkbox for creating a start menu folder.
Figure 3.11. Start menu folder selection
If the Create shortcuts for all users checkbox is activated, a link on the desktop to Offboard Diagnostic Information System Service will be created for each user. If the checkbox is not selected, the link on the desktop is
only visible to the user who installed Offboard Diagnostic Information System Service.
In addition, all users have a link to ODIS Service EDIC Configuration. This link starts the configuration tool PDU
API
Back: The installation goes back one step.
Continue: The Offboard Diagnostic Information System Service installation continues. The copying and installation procedure starts.
Cancel: The installation is cancelled.
A progress bar shows the progress of the copy and installation process.
27
Installation
Figure 3.12. Copying process display
Cancel: The installation is cancelled.
Notice:
The installation process can last several minutes depending on computer speed.
The installation procedure for the PDU-API and MCD server diagnostic components is show separately.
28
Installation
Figure 3.13. PDU API Installation
Figure 3.14. MCD Server Installation
These installation procedures cannot be altered. The buttons are grayed out.
Once the installation procedure is complete for all components, the last view of the installation assistant will open.
29
Installation
Figure 3.15. Completed installation
Finish: clicking on this button will end installation of Offboard Diagnostic Information System Service.
You can now double click the link on the desktop to start Offboard Diagnostic Information System Service.
Offboard Diagnostic Information System Service can also be started through the start menu Start > All Programs>-Offboard Diagnostic Information System Service.
The Offboard Diagnostic Information System Service installation ends the first time the application is started.
The Offboard Diagnostic Information System PostSetup opens.
30
Installation
Figure 3.16. PostSetup start
The installation completion by the PostSetup functions as a software update. It can be performed via the internet
using a preset URL on the importer mirror server. The correct URL, user name and password are needed. If the
installation data for the PostSetup local are available, for example on a DVD, then it is possible to complete the
installation without having to use the internet.
URL: mirror server address (depending on the importer). This field always has a red background; this color
designated and incorrectly entered URL.
Select local directory: open Windows Explorer, which can used to select the directory with the PostSetup files.
User name: User ID for accessing the mirror server
Password: Password for accessing the mirror server.
Cancel: the PostSetup is cancelled.
The PostSetup continues.
31
Installation
Figure 3.17. PostSetup data display
Before the files installation begins, the maximum download size of the files being installed and the download
time for an installation via the internet depending on the type of connection is displayed.
It is possible to navigate backward in steps in the PostSetup using this knob.
32
Installation
Figure 3.18. PostSetup files installation
The diagnostic data and vehicle projects for the brands entered in the license certificate and the help files will
now be installed in the language that was selected at the beginning of the installation. Each file package and the
progress of the installation is displayed in the continuation dialog
Offboard Diagnostic Information System Service can now be used if the installation was completed correctly.
Notice:
It is possible to cancel the installation of the language-dependent diagnostic data, vehicle projects and help files
the first time Offboard Diagnostic Information System Service is started. However, you will not be able to
work with the application.
If shared network drives will be set up for use by several Offboard Diagnostic Information System Service
testers, refer to the Microsoft Windows documentation on setting up shared network drives.
You can set up the folder structure according to your preferences. The Offboard Diagnostic Information System
Service local path structure after the automatic installation and the preset folder names in the expanded Administration area are a good starting point.
Cross-reference:
Refer to "Administration Mode"
33
Installation
Notice:
If Internet Explorer version 6 is selected as the default browser, the following setting must be made so that
communication to the group systems can function correctly:
Figure 3.19. Internet Options for Internet Explorer 6
In the "Advanced" tab for browser internet options, the check mark must be removed from the entry "Show
friendly HTTP error messages".
Notice:
An error message may appear if a firewall is active when installing Offboard Diagnostic Information System
Service. Access to OffboardDiagLauncher.exe must not be blocked.
Note:
Also refer to the "Additional Error Messages" chapter.
34
Installation
35
Chapter 4. Update
There are regular software and data updates for Offboard Diagnostic Information System Service. The update
cycle, the settings for loading in the background and for the automatic updating of the access data can be configured
in Admin.
Note:
Refer to Administration - "General Area" and "Connections Area".
In the Offboard Diagnostic Information System Service start configuration, the system searches for updates
daily. Testing can take place when the program is started, when the program is ended or when ending a diagnostic
session, depending on if a test has already taken place or not on the current date.
The progress of the update search may differ depending if is was executed at the start or end of the application,
at the ending of a diagnostic session or manually.
1.
update search at the start of an application or when ending a diagnostic session
The update search when starting Offboard Diagnostic Information System Service or when ending a diagnostic session runs in the background. If running in the background is configured in the Admin area, then
any updates found are automatically downloaded in the background.
The result of the update search will be displayed by a symbol in the status bar. The following symbols can
be displayed and you can click on them:
: An update was just downloaded. It is possible to pause a download. A dialog opens if you click on the
symbol:
Figure 4.1. Pause download
Close: Closes the dialog and continues downloading.
Pause: Closes the dialog and continue the download.
: This symbol appears if the download was interrupted. Click on this symbol to continue the download.
Downloading continues automatically if a diagnostic session was ended even if was manually continues
before.
When downloading ends, another dialog informs the user that the update can now be installed:
36
Update
Figure 4.2. Updates ready for installation
Yes: Starts the update.
No: The update is not installed. The files to be downloaded are available for installation at a later time.
Yes, shutdown afterward: The update loads and then the operating system shuts down. In this case, the
update process is performed automatically. The user does not have to do anything unless an error occurs.
: The time point for testing the updates is exceeded, or update were downloaded, which can now be
installed. Clicking on the symbol starts either the update check or the update process.
Checking updates has determined that all of the required data is not available on the update server. Clicking the symbol opens the "Missing update files" dialog, described below.
An instruction text with more detailed information appear when the mouse is moved over the symbol.
Clicking on the symbol starts the update check. This runs just just like the check described below when
ending the application.
2.
Update check when ending the application or manually
If check for updates is performed when ending Offboard Diagnostic Information System Service, then the
use see a message. This message closes automatically when the check is ended. The message appears when
the user manually starts the update by clicking on Update.
Figure 4.3. Checking for updates
A message appears if no updates were found.
37
Update
Figure 4.4. No Updates Available
OK: Closes the message window.
If updates were found, a dialog appears where the user has to possibility to install the updates now. If load
in background is not activated in the Admin area, the update is downloaded. If the option is activated, then
the update is downloaded while performing Offboard Diagnostic Information System Service as long as
there are no diagnostic sessions active. This can accelerate the update process.
Figure 4.5. Available updates
Yes: Downloads the update and start the update process.
No: The update is not downloaded and/or installed.
Yes, shutdown afterward: The update loads and then the operating system shuts down. In this case, the
update process is performed automatically. The user does not have to do anything unless an error occurs.
Notice:
Shutting down the operating system can be prevented in any case by other active third-party applications,
for example, by a mail program. Offboard Diagnostic Information System Service has no influence over
these applications. If such applications do prevent automatic downloading, it is recommended to refer to
their documentation.
If it was determined when checking for updates that all of the required files were not on the mirror server, the user
sees an error message. The dialog contains the names of the missing files.
38
Update
Figure 4.6. Missing update files
OK: Closes the dialog without peforming the update.
When the update process starts, a wizard guides the user through the process on several pages.
If there is already an update when starting the application, which was downloaded earlier, then the wizard will
appear just before starting Offboard Diagnostic Information System Service.
Each page of the wizard has three screen buttons:
Next moves to the next page of the wizard.
Back takes you back one step.
Cancel:: Installing the update is cancelled. Offboard Diagnostic Information System Service starts then in the
earlier version.
A warning appears on the first page of the wizard informing the user there are currently diagnostic sessions that
are incompatible when performing the update. This message must be confirmed.
39
Update
Figure 4.7. Warning before updating
The update source, from which it must be taken, must be entered first. If these entries were already done, then
this page of the wizard is no longer displayed.
Figure 4.8. Updating using the network
40
Update
URL: the URL for the update server (Mirrorserver 2) can be changed in an update via the network. The preset
URL is taken from the Admin area and can be changed permanently there.
Select local directory: if the update is installed using a CD/DVD or a network drive, the drive with the inserted
update CD/DVD or the folder on the network drive can be selected using this button. User name and password
are not required for an offline update.
User name: user name entry.
Password: password entry.
The local administrator must be contacted for access to the update server.
An update can made online or offline.
In the case of an offline update, the system checks if the site.xml file is in the specified directory. If it is not, an
error message appears and checking for updates ends.
Figure 4.9. Error message when site.xml is missing
Notice:
An error message may appear if a firewall is active when installing updates. Access to the application file
OffboardDiagLauncher.exe must not be blocked.
Note:
Also refer to the "Additional Error Messages" chapter.
Administrator rights are needed for the operating system on the tester or laptop in order to perform an update.
A progress indicator shows the connection being established to the update site.
Figure 4.10. Establishing a Connection to the Update Site
41
Update
Cancel: the update is cancelled.
Once the connection to the update site is established, the Offboard Diagnostic Information System Update
indicates the size of the available updates and the estimated time required for download depending on the type of
internet connection. If the memory requirements needed exceed what is actually available, then a message appears
informing the user.
Figure 4.11. Warning when there is insufficient disk space
The save location can be changed in this case, for example, to a different hard drive disc or partition. Clicking on
Directory opens a file selection dialog, in which the new save location can be selected. The OK screen button is
active if there is sufficient space in the new save location.
OK: Continues the update process.
Cancel: Switches back to the configuration data entry. From here, you can either cancel the update process or
restart it, for example, after cleaning the hard drive disc.
If there is sufficient disk space and an update was found, the size of the update and the estimated download time
are displayed.
Figure 4.12. Available Updates Display
42
Update
If there is no update data available, Offboard Diagnostic Information System Service will show the following
message:
Figure 4.13. No Updates Available
If update data is available, there will be updates for the following areas:
1) Individual program sections of Offboard Diagnostic Information System Service, if they are licensed.
2) Data that was edited by Offboard Diagnostic Information System Service, such as diagnostic data, test programs and similar.
3) Programs offered by third parties such as MCD server or virtual keyboard.
The progress indicator shows the progress of the installation for all update components.
Figure 4.14. Update progress indicator
Cancel: Installing the update is cancelled.
If there are errors during the update process, these will be shown all together to the user.
43
Update
Figure 4.15. Error when performing an update
The individual error messages are listed in detail in the dialog text field.
OK: Closes the dialog.
Notice:
The data update may take a long time, depending on the amount of data.
With updates to third-party applications, individual installation routines may start. If this happens, follow the
instructions they provide.
44
Update
45
Chapter 5.
interface
Application
start/user
This chapter contains a brief introduction about the user interface and how to work with Offboard Diagnostic
System Information Service. When individual functions are discussed, there are cross references to additional
chapters in this manual if detailed descriptions are available.
Offboard Diagnostic System Information Service is started through the Windows start menu after installing:
Figure 5.1. Starting Offboard Diagnostic Information System Service
You can also open the virtual keyboard under "Keyboard" in the Windows Start menu.
The license is checked for validity when the program starts. If the license is still valid for 14 days or less, a dialog
informs the user and requests to extend the license. There must be an applicable URL for eShop so that a connection
to eShop can be established.
Figure 5.2. Message stating the license will soon expire
Yes: Starts renewing the license.
No: cancel the renewal.
Chooses the brand in the left list for which the license is being renewed.
If the user selects yes, a dialog appears to log into the group systems. Enter the user name and password here.
Figure 5.3. Logging into the group systems for extending a license
46
Application start/user interface
Accept: Performs the registration.
Cancel: Cancels the registration. In this case, the license cannot be renewed.
If the registration was successful, the system will now try to get the licenses from eShop.
If successful, the user sees another dialog:
Figure 5.4. Success message when the license has been extended
OK: Closes the dialog and continues starting Offboard Diagnostic Information System Service.
In the case of an error, another dialog appears:
Figure 5.5. Error message when extending the license
OK: Closes the dialog and continues starting Offboard Diagnostic Information System Service.
If the license could not be extended or if the process was interrupted, then the dialog for extending the license
appears each time Offboard Diagnostic Information System Service starts. The dialog also always appears when
the application is started after the expiration date of the license has already been passed. The application stops
if license renewal fails.
Once the startup process is complete, the user interface is shown in the Diagnosis mode.
A window with warnings and notes to observe also opens.
47
Application start/user interface
Figure 5.6. Windows with warnings/notes (part 1)
Notice:
The OK button for closing the window with warnings and notes is only active once you have scrolled or paged
through the entire text.
Figure 5.7. Windows with warnings/notes (part 2)
48
Application start/user interface
Ok: The window will close.
After closing the window, Offboard Diagnostic System Information Service is ready for work.
Cross-reference:
For more detailed information, refer to "Additional Functions/Information"
If there are diagnostic logs from an earlier diagnostic session when you start the program that were not sent (for
example, the application was ended incorrectly), they will be sent now. A message to the group system is necessary
here.
Figure 5.8. Message regarding transmission of the diagnostic log
The global user ID and password for group systems access are required to log in.
Transfer: the login data are sent to the group systems. The diagnostic log that was automatically stored is sent
after a successful login.
Cancel: The Cancel are discarded and the attempt to send is cancelled.
49
Application start/user interface
Figure 5.9. Offboard Diagnostic Information System Service User Interface
The user interface
is divided into several areas:
Info area
Working area (client area)
Operating modes and standard functions
Status area
The individual areas serve the following purposes:
Information area
The Information area contains general information about the license, the order and the vehicle that is currently
connected.
Figure 5.10. The Info area
50
Application start/user interface
The left area shows the importer, dealer and order number.
The center area contains the vehicle ID and the engine code.
For independent market operators, the remaining runtime of the diagnostic flat rate is shown in the center area
after logging into the group systems.
The right area uses symbols to indicate if:
•
there is a diagnostic connection to the vehicle
there is a diagnostic connection,
there is no diagnostic connection,
no diagnostic connection is detected.
•
there is a network connection
there is a network connection,
there is no network connection.
•
the ignition is on
the ignition is switched on,
the ignition is switched off,
the ignition status was not detected.
Notice:
When there is no network connection, there is no connection to the group systems. Functions that depend on a
connection to the group systems, such as flashing or TSBs, are not available.
Work area (Client area)
The work area is the central part of the application. All relevant data that are available during diagnosis and testing
- such as wiring diagrams, test plans and measuring results - are displayed here. All data is also entered here, such
as entering measurements in tests, selecting test steps and identifying control modules individually.
Each operating mode has a tab bar in the work area with various tabs. Individual tabs will be activated depending
on the type and scope of the work session. Inactive tabs have no content and are grayed out.
51
Application start/user interface
Tab bar for the Flashing mode:
Tab bar for the Diagnostic mode:
Tab bar for the Info mode:
Tab bar for the Admin mode:
Notice:
In the tab bar for the Info mode, the tabs Work Orders and History are not available for independent market
operators.
Operating modes and standard functions
In the Operating modes menu, you can click the desired button to switch to various operating modes .
Figure 5.11. Operating Modes Menu
The following operating conditions are available:
Diagnosis:
OBD:
Flashing: operating mode
52
Application start/user interface
Measurement: operating mode
Info:
Admin: operating mode
The following chapters describe the individual operating modes.
Notice:
You can only switch between the Diagnosis and Flashing operating modes if the current diagnosis or flash session
was already ended.
Cross-reference:
Refer to "Ending Diagnosis"
Refer to "Data/Diagnostic Session"
The standard functions menu contains functions that can be accessed at any time in Offboard Diagnostic Information System Service .
The following standard functions are available:
Figure 5.12. Standard Functions Menus
Using the log submenu,
53
Application start/user interface
Figure 5.13. Log submenu
•
logs from Guided Fault Finding and OBC can be saved and printed.
•
Logs from Guided Fault Finding can be sent and copied,
•
OBD logs can be generated, edited and displayed.
Cross-reference:
Refer to "Log".
Notice:
By clicking on the name line, you can expand
and minimize the menus on the right side.
.
Using the Data submenu, you can
54
Application start/user interface
Figure 5.14. Data submenu
•
print current views,
•
pause diagnostic sessions and resume them later and
•
download hotfixes.
Cross-reference:
Refer to "Data".
The Extras submenu contains:
Figure 5.15. Extras Submenu
•
the search function,
•
the possibility to change the diagnostic interface
•
the road test mode,
•
the possibility to update the application.
Note:
Refer to "Extras".
55
Application start/user interface
The Help submenu contains the following functions:
Figure 5.16. Help Submenu
•
Online help and
•
the feedback function for support inquiries.
Note:
Refer to "Help".
The Info submenu contains:
Figure 5.17. Info Submenu
•
information on new functions under the News section,
•
information on software and data versions and
•
warnings, cautions and notes.
Status area
The status area displays the current process and status.
Figure 5.18. Status Area - Sample Test Plan Calculation
For example, the progress when calculating the test plan can be tracked during diagnostic entry.
The buttons for adjusting the size of the work area and ending Offboard Diagnostic Information System
Service are located on the right near the status bar.
The Hide button hides the operating modes and standard functions area.
The Show button can be used to display this area again.
56
Application start/user interface
Clicking on the Full screen button hides the Information area and the operating modes and standard
functions area.
To show the Information area and the operating conditions and standard functions area again, click
the button.
This button ends the Offboard Diagnostic Information System Service program. After clicking this
button, a prompt appears asking if you really want to end the program. Offboard Diagnostic Information System
Service will end after you confirm with Yes. If Guided Fault Finding was performed, it must be ended first.
Otherwise the system will ask if a support request should be send at the end of the diagnostic session.
Note:
Refer to "Ending Diagnosis"
5.1. Operation
Offboard Diagnostic Information System Service can be using the mouse and keyboard as well as the touchscreen. The buttons are displayed larger for easier operation on the tester and the touchscreen.
5.1.1. Touchscreen
A touchscreen is a sensor screen that is present on some diagnostic devices. The user touches buttons with the
finger and/or a stylus instead of using a mouse and keyboard.
Note:
The right mouse button is not used with the touchscreen. Menus and buttons that are accessed with the right mouse
button are displayed by pressing and holding the desired button on the touchscreen for approximately 1 second.
5.1.2. Mouse and Keyboard
The mouse can be used to operate the program. Place the cursor on the desired button and click the left mouse
button to confirm.
Menus and buttons in the context menu that are accessed using the right mouse button can also be accessed by
clicking and holding the left mouse button for approximately one second.
The keyboard is needed to enter values in test programs or Guided Functions when required by the test steps.
Manual VIN entry also requires a keyboard.
5.2. Screenshots for support requests
In many Offboard Diagnostic Information System Service dialogs, error messages and message dialogs, there
is a screen button with symbol of a camera on it at the bottom on the left side. This makes it possible to make
a screenshot of the current view.
57
Application start/user interface
If a support request is made after that, then the screenshot is added automatically to the request.
Example:
The screen button for making a screenshot is available in this message:
Figure 5.19. Making a screenshot
If you use the screen button, the application makes a screenshot of the actual surface of Offboard Diagnostic
Information System Service.
Many screenshots can be generated if desired. When a support request is generated the next time, the screenshots
are contained there already in the free text window.
Figure 5.20. Support request with a screenshot
Note:
For more information regarding generating a support request, see "Support"
58
Application start/user interface
5.3. Control module negative response display
Negative response codes from the control module are displayed in Offboard Diagnostic Information System
Service only if they cancel the started diagnostic function. A Note from the control module with the coded
control module response code opens in this case.
Figure 5.21. Note from the control module with Negative Response Code
The negative control module response (NRC = Negative Response Code) coded value displayed here has a
different meaning according to the control module log.
The meanings of the hexadecimal NRC for KWP 2000 and KWP 1281 are listed in the following tables.
NRC (Hex value)
Negative response name
Meaning
10
generalReject
No closer specified rejection to the
tester request
(also for OBD)
11
FunctionNotSupported / invalidFor- The desired function is not supported
mat
in the specified parameters or not at
all.
12
SubfunctionNotSupported / invalid- The desired subfunction is not supFormat
ported in the specified parameters or
not at all.
(also for OBD)
21
busyRepeatRequest
59
The previous request is still not processed, a new request is rejected
without being saved.
Application start/user interface
NRC (Hex value)
Negative response name
Meaning
22
conditionsNotCorrect or requestSe- The conditions for performing the
quenceError
function are not met or requests, that
must be processed in a specific sequence, were sent an incorrect sequence.
23
routineNotComplete
The service is being processed, the
process is still
not completed
31
requestOutOfRange
One or more of the parameters are
outside of a permissible
value range
33
securityAccessDenied / securityAc- Processing the service requires a SecessRequested
curityAccess,
that was not processed or was incorrect
35
invalidKey
Incorrect access authorization
36
exceedNumberOfAttempts
The maximum number of incorrect
access attempts through
SecurityAccess was exceeded
37
requiredTimeDelayNotExpired
The wait time after a specific number
of
incorrect attempts to gain access to
the control module, is
not complete
40
downloadNotAccepted
Download not accepted
41
improperDownloadType
Incorrect download type
42
canNotDownloadToSpecifiedAddress
Download not possible to the requested address
43
canNotDownloadNumberOfBytesRequested
Download does not have the correct
length
50
uploadNotAccepted
Upload not accepted
51
improperUploadType
Improper upload type
52
canNotUploadFromSpecifiedAddress
Cannot download from the specified
address
53
canNotUploadNumberOfBytesRequested
Upload does not have the correct
length
71
transferSuspended
Transfer suspended
72
transferAborted
Transfer aborted
74
illegalAddressInBlockTransfer
Illegal address in block transfer
75
illegalByteCountInBlockTransfer
Illegal byte count in block transfer
76
illegalBlockTransferType
Illegal block transfer type
77
blockTransferDataChecksumError
Block transfer data check sum error
60
Application start/user interface
NRC (Hex value)
Negative response name
Meaning
78
requestCorrectlyReceived-Respon- The service was received correctly
sePending
and is being processed, however the
response is pending. (also for OBD)
79
incorrectByteCountDuringBlockTransfer
80
serviceNotSupportedInActiveDiag- Service not supported in active diagnosticMode
nostic mode
90
noProgramm
Illegal byte count in block transfer
The flash in the control module does
not contain a program and the control module is in the boot sector. After restarting the
diagnostic data transfer, only update
programming is possible.
91
scalingNotSupported
The tester uses the scaling as
determined for KWP1281.
Table 5.1. Table 1: Negative Response Code (NRC) from control module at KWP 2000
Block title/content
Negative response name
Meaning
0A block counter old
No Ack -1
Error during data transfer
0A block counter
No Ack UB
Function is either unknown or cannot
be performed at the moment
Table 5.2. Table 2: negative response from the control module at KWP 1281
On control modules with UDS protocole, the negative response is constructed as
7F <service number> NRC
The NRC (Negative Response Code) is service-specific but often conforms to the meanings in KWP 2000. If
needed, ISO Standard 14229 or VW Standard VW-80124 is recommended.
61
Chapter 6. Diagnosis Operating Mode
This chapter covers the scope of functions in the Diagnosis mode.
6.1. Diagnosis Procedure
The following chapters describe the typical work procedure in a diagnostic session with Offboard Diagnostic
Information System Service. A diagnostic session is characterized by the steps diagnostic entry, test plan and
special functions, working with Guided Fault Finding (GFF) and ending the diagnosis.
Figure 6.1. Diagnostic Entry Process
In the diagnostic entry section, a connection to the vehicle is established, the vehicle is identified (GMD), the
login to the group systems is completed, a matching order is selected from ElsaPro the vehicle control modules
are identified and, lastly, the GFF start is initiated.
In the test plan and special functions section, the start module and traversal tests are completed and the test
plan is calculated automatically and adapted manually using DISS and TSB, if needed. The test plan and special
functions for Guided Fault Finding are available at the end of this section.
The completion of GFF tests is the focus of the working with GFF section.
In the end diagnosis section, the diagnostic session is completed with the clearing of the DTC memory, the
performing of end modules and the option for feedback.
In addition to this typical diagnostic session procedure, there are additional options in the Diagnosis operating
mode such as marking control modules as installed later, switching control module versions, checking individual
control modules using Guided Functions or performing a complete self-diagnosis.
62
Diagnosis Operating Mode
6.2. Diagnostic entrance
In the diagnostic entry section, a connection to the vehicle is established, the vehicle is identified (GMD), the
login to the group systems is completed, a matching order is selected from ElsaPro the vehicle control modules
are identified and, lastly, the GFF start is initiated.
Figure 6.2. Diagnostic Entry Section
63
Diagnosis Operating Mode
6.2.1. Start diagnosis
The Start diagnosis section describes how to connect the vehicle to Offboard Diagnostic Information System
Service.
Figure 6.3. Start Diagnosis Section
Figure 6.4. Entry Window after Starting the Application
After starting Offboard Diagnostic Information System Service, the user interface is shown in the Diagnostic
mode with no vehicle data.
First the diagnostic hardware is detected. This process may last several minutes.
64
Diagnosis Operating Mode
Notice:
Figure 6.5. Unpermitted Bluetooth Connection
Yes: You will work with Bluetooth at your own responsibility.
No: A Bluetooth connection will not be established.
The use of Bluetooth connections is not permitted in all countries. If communication to the vehicle is established
via a Bluetooth connection (for example, VAS5054) in one of these countries, Offboard Diagnostic Information
System Service will display a message to inform you of this.
Note:
For a detailed description of changing diagnostic hardware, refer to "Extras/VCI".
65
Diagnosis Operating Mode
Figure 6.6. Diagnostic entrance start window
The Diagnosis operating mode must be activated to start vehicle diagnosis. The entry window indicates if a
connection to the vehicle has been established and if the ignition is switched on.
Clicking on this button will start diagnostic entry.
Diagnostic entry runs in the Control modules tab.
Once diagnostic entry has started, it can be stopped by clicking on this button.
A diagnosis that has already been performed can be ended using this button. This does not close Offboard Diagnostic Information System Service.
66
Diagnosis Operating Mode
Notice:
Offboard Diagnostic Information System Service make Diagnosis and Flashing available only to licensed
markets.
You can check the license content in the Administration area:
Refer to "Administration/General/License Info"
An independent market operator must log in to the group systems at the beginning of a diagnostic or flash
session online.
If the login is interrupted, Offboard Diagnostic Information System Service will return to the start screen.
After logging in successfully, Offboard Diagnostic Information System Service shows the remaining period of
validity for the flat rate in days and hours under Remaining runtime in the Information area of the application
interface. See illustration information area.
The independent workshops do not have access work orders and History.
At the start of diagnostic entry, Offboard Diagnostic Information System Service checks the vehicle status
in terms of battery and ignition status:
•
Is the battery connected (terminal 30 - battery voltage)?
•
Is a vehicle connected (terminal 30 - battery voltage)?
•
Is the vehicle ignition switched on (terminal 15 - ignition)?
If the battery is not connected, the Battery not connected dialog appears.
Figure 6.7. No vehicle connected
If a vehicle is not connected, the message No vehicle connected appears.
Figure 6.8. No vehicle connected
67
Diagnosis Operating Mode
Repeat: the vehicle connection is checked again.
Continue: the system continues the diagnostic entry.
Cancel: The diagnostic entry is cancelled.
If a vehicle is connected, the system will check the ignition status next without providing any messages.
If a vehicle is not detected even though the diagnostic connector is connected correctly, the message Vehicle
detection not possible appears.
Figure 6.9. Vehicle recognition not possible
Repeat: vehicle identification is performed again.
Continue: the system continues the diagnostic entry.
Cancel: The diagnostic entry is cancelled.
Diagnostic entrance continues automatically without any more messages if the system detects that the vehicle
ignition is switched on.
If the ignition is switched off, the message Ignition switched off appears.
Figure 6.10. Ignition is switched off
Repeat:: the ignition is checked again.
Continue: the system continues the diagnostic entry.
Cancel: The diagnostic entry is cancelled.
If the ignition status is not detected, the message Ignition status not detected appears.
68
Diagnosis Operating Mode
Figure 6.11. Ignition status not recognized
Repeat: the ignition status is checked again.
Continue: the system continues the diagnostic entry.
Cancel: The diagnostic entry is cancelled.
Notice:
The status of the battery, ignition and vehicle recognition are checked during the following activities:
•
Diagnostic entrance
•
Reading a control module DTC memory
•
Reading DTC memory for all control modules
•
Manual control module identification
•
Diagnostic exit
Note:
Diagnostic entry may last several minutes.
Notice:
Offboard Diagnostic Information System Service cannot be ended while compiling the control module list.
The current progress of the diagnostic entry is indicated at the lower right of the user interface.
Figure 6.12. Status Area - Example of Determining a VIN
69
Diagnosis Operating Mode
6.2.2. Vehicle Features Dialog (VFD)
The following section describes the identification of a vehicle based on its features.
Figure 6.13. Performing the Vehicle Features Dialog Section
The central element is the dialog Vehicle Features Dialog (GMD).
Figure 6.14. Dialog for selecting vehicle features
If the battery and ignition status are OK, the VIN is read from the vehicle and the dialog Vehicle features appears
for selecting vehicle features.
The VIN can be corrected manually if necessary by switching vehicle identification from automatic to manual.
A detailed description of the change between automatic and manual will be provided below.
Cancel: the vehicle identification and diagnostic entry are cancelled.
The decision is also made in the vehicle features dialog if Guided Fault Finding will be used in the diagnostic
session or not.
70
Diagnosis Operating Mode
Figure 6.15. Guided Fault Finding inquiry
Work with Guided Fault Finding is automatically selected by default in the vehicle features dialog each time
diagnosis starts. A warning that indicates the results will appear if this option is deselected.
Only Self Diagnosis and Guided Functions are available.
Yes: the diagnostic session is continued without Guided Fault Finding. You can only continue working without
an order.
No: Diagnosis continues with Guided Fault Finding
Note:
For additional information on OBD, refer to the "On Board Diagnosis" chapter.
The vehicle identification for determining GFF diagnostic data in the vehicle features dialog can be performed
automatically or manually. Vehicle features that were not identified clearly must be identified manually.
If an error occurs during automatic identification, a message appears with the request to identify the vehicle manually.
Figure 6.16. Error during automatic identification
71
Diagnosis Operating Mode
OK: Identification mode switches to manual.
There are two basic reasons why the automatic identification fails:
•
An error occurs when reading the VIN, for example due to a faulty control module.
•
An error occurs when checking the diagnostic data associated with the VIN, the database is out-of-date or
incorrect.
If no error occurs during automatic identification, you can switch between automatic and manual mode.
When changing from automatic to manual mode, all of the previously determined vehicle features remain,
but they can be changed. If vehicle features are changed, all previously selected features become invalid. When
changing from manual to automatic mode, all of the vehicle features that were entered manually and checked
for validity remain. This means the validity of manually entered features is checked again automatically and they
are modified if necessary. For example, an invalid VIN is replaced with the VIN that was read automatically.
Figure 6.17. Entering the VIN Manually
In manual mode, the VIN that was entered is checked for plausibility. For example it must be the correct length
(17 characters). There is no additional functional test of the VIN. The VIN that was entered manually must be
plausible in order to continue manual vehicle identification. Otherwise there are no restrictions or dependencies
when selecting from the vehicle features that are offered.
Notice:
If a plausible but technically incorrect VIN was entered, Offboard Diagnostic Information System Service
may prepare tests for GFF that do not lead anywhere due to the incorrect prerequisites. Manual VIN entry should
be used with caution.
In automatic mode, it is not possible to change the VIN and the identified vehicle features.
After determining the VIN, vehicle identification continues.
In the vehicle features dialog, there are several list fields that make it possible to select from several suggestions,
if available.
Select the vehicle manufacturer in the Manufacturer list field.
The models produced by the selected manufacturer are displayed in the Model list field.
72
Diagnosis Operating Mode
After selecting the model, select the model year for the selected vehicle in the Model year list field.
When the model year is selected, the version type can be selected in the Versions list field (for example: sedan,
wagon, etc.).
Lastly, the vehicle engine is selected in the Engine list field.
Notice:
If the vehicle is switched during a diagnostic session, Offboard Diagnostic Information System Service reads
the VIN again and indicates that the vehicle has changed.
Each vehicle change is entered in the diagnostic log.
Note:
Each of the individual list fields are only active if a selection was made in the list field above.
73
Diagnosis Operating Mode
Click Accept to accept the vehicle basic features. The vehicle is identified.
6.2.3. Using the K-line adapter
Certain vehicles may require use of the K-line adapter. If Offboard Diagnostic Information System Service
detects such a vehicle, a dialog opens where the user is prompted to connect the K-line adapter.
If the vehicle features dialog is shown, the prompt to use the K-line adapter appears immediately after closing the
dialog. Otherwise, the prompt appears after the VIN is determined.
Figure 6.18. Using the K-line adapter
The user must confirm the process using the checkbox. The OK button will only be active after that.
OK: Continues the diagnostic entrance.
Cancel: Closes the dialog and cancels diagnostic entrance.
74
Diagnosis Operating Mode
6.2.4. Logging in to Group Systems
The next step after vehicle identification is logging in to the group systems.
Note:
This steps is deleted if Offboard Diagnostic Information System Service is in offline mode. The login window
in this this is first displayed when an action is being performed that requests a login.
Figure 6.19. Logging in to Group Systems Section
Offboard Diagnostic Information System Service opens a login window in order to log in.
Figure 6.20. Group Systems Login Window
The login is required once per session. The global user ID and password for group systems access are required
to log in.
Transfer: the login data are sent to the group systems.
Cancel: the login data are discarded. Authorized dealers can repeat the login at any time.
This button is available in all views of Offboard Diagnostic Information System Service that use data from
the group systems. It can be used to log in again at any time.
After logging in successfully, access to services such as ElsaPro, CarPort, DISS, etc. is possible in the course of
the diagnostic session.
75
Diagnosis Operating Mode
Notice:
An independent market operator must log in to the group systems at the beginning of a diagnostic or flash
session online.
If the login is interrupted, Offboard Diagnostic Information System Service will return to the start screen.
After logging in successfully, Offboard Diagnostic Information System Service shows the remaining period
of validity for the diagnostic flat rate in days and hours under Remaining runtime in the Information area of
the application interface.
The independent workshops do not have access work orders and History.
6.2.4.1. Authentication with SecurID
The group system login for independent market operators is performed using the internet. A SecurID card and
different authorizations are needed. The following describes registering using the SecurID card.
The authentication is performed according to the principle two-factor authentication:
•
Must know: User ID + PIN
•
Must have: SecurID card
Figure 6.21. SecurID card
76
Diagnosis Operating Mode
6.2.4.1.1. Prerequisites
The following prerequisites must be met in order to use the SecurID card for authentication:
•
Network connection to the internet (proxies with authentication are not supported)
•
GeKo and, if needed, SVM authorization
•
Volkswagen Internet WebService Access Authorization
When referring to authorizations the following must be differentiated:
•
Volkswagen Internet WebService Access Authorization and
•
Application Authorization (for example, GeKo)
Both authorizations must be requested for the same user ID!
Notice:
All authorizations are user-specific!
The SecurID card may not be used by others!
The owner of the independent market operator is responsible for the cards!
The following components are needed for the Volkswagen Internet WebService access authorization:
•
Global user ID
•
SecurID card
•
PIN (password)
77
Diagnosis Operating Mode
6.2.4.1.2. First registration on the WS gateway
It is necessary to create a PIN before the logging in the first time or if the PIN was reset. This is referred to as
the new PIN mode.
Notice:
The user selects a 4 to 6 digit number for the PIN. The PIN must be kept confidential and may not be shared
with another person!
To create the PIN:
•
Enter the following internet address (URL) in your browser: https://ws-gateway.vw-group.com/wsgwpin/app
•
Enter the global user ID and the actual displayed SecurID card number code (token) in the fields (see illustration):
Figure 6.22. Create PIN
•
Confirm with Log in.
•
It is necessary to enter the new PIN in the Pin field in the following window. The PIN must contain 4 to 6
numbers. The PIN is confidential and must not be given to another person!
Figure 6.23. Assign PIN
78
Diagnosis Operating Mode
•
Confirm with Set pin.
•
Enter the assigned PIN in the Pin field.
•
Wait until the next token on the SecurID card is displayed and then enter it in the Token field:
Figure 6.24. Check the PIN and confirm it with the token
•
Confirm with Log in.
•
"Log in successful" will be displayed if the setting the PIN was successful.
Figure 6.25. PIN created successfully
Note: It is possible to check if the registered user has GeKo authorization for this brand by selecting the brand in
the Brand field and then confirming using the Test Service button.
79
Diagnosis Operating Mode
6.2.4.1.3. Additional messages on the WS gateway
The message Offboard Diagnostic Information System Service always checks the global user ID and password.
Do the following when entering the password:
•
Enter the user ID in the global user ID field.
•
First enter the password in the password field and then enter the displayed token (TTTTTT) from the SecurID
card.
Note: the small bar on the left side of the SecurID card display shows the validity of the displayed token.
The following is an example of a dialog for when entering the values:
DP12345 = Global user ID (GUID)
pppppp = 4-6 digit PIN
TTTTTT = 6-digit token
Note: only the place holder appears in the actual dialog field when entering the password.
Figure 6.26. Password input screen
Transfer: the login data are sent to the group systems.
Cancel: the login data are discarded.
80
Diagnosis Operating Mode
6.2.5. Select order
After logging in to the group systems, an order is selected for the diagnostic session. It is also possible to work
without an order. This is decided in this section.
Figure 6.27. Work order selection section - diagnostic entrance
The same procedure takes place when entering a flash session in the Flashing mode.
Figure 6.28. Work order selection section - Flash entrance
In the course of flash entrance, the selected work order is displayed in the Work orders tab after logging into the
group systems. The procedure for selecting the work order is the same in both modes.
Note:
The work order selection during flash entrance is also described in "Flashing/work order selection mode".
The view changes to the Orders tab after logging in to the group systems.
81
Diagnosis Operating Mode
Figure 6.29. Order View during Diagnostic Entry
Offboard Diagnostic Information System Service lists all available orders for the identified vehicle in the Orders tab.
In the work order list, the work order number is displayed under Work order, the current status in the service core
process is displayed under SCP status, and the vehicle license plate number, the deadline for the work order
and descriptive text about the work order are also displayed.
The table that follows lists the meaning of the SCP status numbers.
SCP Status No.
Meaning
1
Appointment scheduling
2
Appointment preparation
3
Vehicle drop-off
4
Performing work
5
Quality control
6
Vehicle return
7
Follow-up
8
Completed
Table 6.1. Meaning of the SCP Status Numbers
Offboard Diagnostic Information System Service checks if there is an online connection to the group systems
in order to load order and vehicle data from ElsaPro.
82
Diagnosis Operating Mode
The web service configuration for access to ElsaPro is described here:
Note:
Refer to "ElsaPro connections"
Usually, the login to the group systems at the start of diagnostic entry is successful. If not or if the online connection
was interrupted after logging in, the following error message appears.
Figure 6.30. Login to Group Systems Not Possible
It is possible to log in again and correct the login data, if necessary.
Transfer: the login is performed again.
Cancel: the login is cancelled. As result, no data from the group systems such as orders from ElsaPro will be
available.
Note:
Using the button,
you can reload order data from ElsaPro. Authorized dealers can also log into the the group
systems again. This button is available in all views of Offboard Diagnostic Information System Service that
use data from the group systems.
Note:
Refer to "Info Mode"
If there is a connection to the group systems, Offboard Diagnostic Information System Service lists all of the
orders available in ElsaPro.
83
Diagnosis Operating Mode
Figure 6.31. Order list view
The desired order must be clicked to display order details.
Details: clicking on this button displays the order details.
84
Diagnosis Operating Mode
Figure 6.32. Order detail view
In the Detailed order view, subareas are displayed under Order ( Order type, Order date, Order status and Pickup date), Customer (Name, Title, Address and Telephone), Order items with information about Item number,
Type and Text, as well as DISS concerns with DISS concern ID, Customer comments, Customer code and
TSB from DISS
Note:
For information on DISS concerns, refer to "DISS/TSB".
Show order list: by clicking on this button, you can switch from the detailed view back to the order list.
You can select an order for the diagnostic session from this list or you can enter an order with a manual order
number.
You can select a marked order with order number from ElsaPro for the diagnostic session by clicking on the
Select order button.
If a work order was selected, which has no DISS complaints, then an applicable message appears.
85
Diagnosis Operating Mode
Figure 6.33. No DISS concerns
OK: The message closes and the work order selection continues.
If there is no connection to the group systems, a standard order for working with a manual order number can
be entered. It is possible to assign a number to this order and select it for the diagnostic session.
Figure 6.34. Entering the order number
If a manual order number must be assigned, you must mark the standard order for working with manual order
number in the list by clicking with the left mouse button.
Own work order no. ...: clicking this button opens a window for entering the order number that can be entered
as free text consisting of letters and numbers.
86
Diagnosis Operating Mode
Transfer: the order number is used.
Cancel: an order number is not assigned.
Without order: diagnostic entry will continue without an order.
Figure 6.35. "Work without order" selection
You must click the Without order button.
Notice:
Only orders with order numbers can be selected for a diagnostic session. The selected order applies to the entire
diagnostic session. It cannot be changed.
An order is required to invoice warranty.
The order number is added to the diagnostic log.
OBD is not available in a diagnostic session with an order.
This completes the order selection.
87
Diagnosis Operating Mode
6.2.6. Control module identification
Control module identification begins after order selection. Offboard Diagnostic Information System Service
evaluates the Gateway components list first.
Figure 6.36. Identifying Control Modules Section
It is necessary to set up communication to the Gateway control module. If this fails, the user receives a dialog.
This differs depending if diagnostic objects for communication malfunction is available for the vehicle. If not,
the following dialog appears:
Figure 6.37. Gateway control module malfunction in communication
Cancel: The diagnostic entry is cancelled.
Repeat: The system tries again to set up communication with the Gateway control module.
Continue: The diagnostic entry contoinues although there is no connection to the Gateway control module. A list
of devices cannot be determined.
88
Diagnosis Operating Mode
If the diagnostic objects for communication malfunctions is available for the vehicle, then a different dialog rather
than the one described above is displayed, which offers the user the possibility to perform a test program to correct
the malfunction.
Figure 6.38. Communication malfunction Gateway control module with communication test
Perform communication test: The progress of the Guided Fault Finding is displayed. The diagnostic objects
for communication malfunctions is performed to correct the malfunction. The diagnostic entry ends after the test
program is performed and the start screen for diagnostics mode is displayed. From here, a new diagnostic entry
can take place.
Repeat: The system tries again to set up communication with the Gateway control module.
Continue: The diagnostic entry contoinues although there is no connection to the Gateway control module. A list
of devices cannot be determined. The diagnostic object for communication malfunctions is included in the test
plan and can be performed from there.
If the vehicle is marked in the equipment network for CAN diagnosis, the Gateway components list with information on the communication protocol, the vehicle specified installation, the vehicle actual installation and the
current DTC memory status is read.
If a difference between the vehicle specified installation and actual installation is found based on the status information from the Gateway components list, Offboard Diagnostic Information System Service opens a Check
components list window with the control modules listed in the order provided by the Gateway. This components
list can be sorted in the test window according to diagnostic address, control module name, coding status and
installation status.
89
Diagnosis Operating Mode
Figure 6.39. "Check components list" dialog
The installation status is indicated with these symbols:
The specified installation that is displayed matches the actual installation.
The specified installation that is displayed matches the actual installation. The specified installation was
changed and not coded yet.
The specified installation that is displayed does not match the actual installation.
The specified installation that is displayed does not match the actual installation. The specified installation
was changed and not coded yet.
Close: The window is closed.
The installation status can be edited through Coding status.
90
Diagnosis Operating Mode
Figure 6.40. Editing the coding status
Only the coded or not coded setting can be edited.
To edit, highlight the control module with the mouse and right-click in the coding status to open the list window
for selection.
Coded means the control module is contained in the specified components.
Not coded means the control module is not contained in the specified components.
Perform coding: the changes to the coding settings are accepted and the components list is read again. If there
are still differences between the actual and specified components, the dialog appears again.
Close: ends the component list check and accepts the existing coding.
Note:
For the following automatic control module identification, a readout plan is created in the background that
includes all control modules that are addressed independently during identification by the system. The readout
plan consists of information about the MCD project, Gateway components list and control module nodes in the
equipment network. This reduces the list to the control modules that are most likely to be installed in the vehicle.
If control modules marked in the equipment network as definitely installed are not recognized in automatic identification, it is possible to have them read out again. The Unrecognized control modules (definitely installed)
dialog opens.
91
Diagnosis Operating Mode
Figure 6.41. "Unrecognized control modules" dialog
All unrecognized control modules are displayed in the left field of the dialog. Marking one or more control modules
and clicking the arrow button > will move them to the right window to be identified again.
Control modules can also be moved to the left window using < if you do not wish to repeat the identification.
Repeat readout: clicking this button begins another attempt to read these control modules. If the control modules
are still not recognized, the dialog opens again. The list of control modules then contains only the ones that were
selected before.
Close: this button closes the dialog and ends the repeated identification.
Variant identifiction with UDS control modules
In the case of UDS control modules, no suitable diagnostic data may be found for the variant during variant identification. This can happen if the diagnostic data is not up-to-date. In this case, Offboard Diagnostic Information
System Service offers the option of working with the base version. A note will alert the user that diagnosis with
the base version is limited.
Figure 6.42. "Working with base version" dialog
92
Diagnosis Operating Mode
Continue: Continues the diagnostic entrance with the base version.
Cancel: Closes the dialog and cancels diagnostic entrance.
If the user decides to diagnose using the base version, an entry about that will be created in the error messages
section of the diagnostic log. If multiple base versions are used, an entry will be generated for each one. The entries
will all be logged under the error number ODS6910E.
6.2.6.1. Control module list
The control modules can be viewed in the control module list or in the networking diagram. The desired view is
opened using the corresponding button.
Figure 6.43. Control module list view
The Control module list shows the control modules that are part of the maximum installation. The control modules
installed in the vehicle are shown in black. The unidentified control modules are shown in gray. Control modules
marked as "installed" afterward are shown in black italics. Control modules with DTC memory entries are shown
in red.
The Control modules table has three columns.
Address column
The Address column shows the diagnostic address for each control module.
DTC column
The DTC column shows the number of DTCs for each control module.
93
Diagnosis Operating Mode
Name column
The Name column shows the name of each control module.
Figure 6.44. Control module information
There is additional information about the control module in parentheses after the control module name. The name
of the version is only displayed when the version is set.
System name
Version
Software part number
Software version number
System name
There are several options for sorting the columns.
The Sorting button opens additional buttons for sorting the table contents.
Figure 6.45. Sorting the Control Module List
Click the Ascending address: button to sort the control modules according to the value of the diagnostic address
from low to high.
The DTC ascending: button sorts the control modules according to the number of DTCs.
The Name ascending: button lists all control modules in alphabetical order.
There are three sorting possibilities for address, DTC and name:
1) ascending (address number, number of DTCs, control module name)
2) descending (address number, number of DTCs, control module name)
3) unsorted (address number, number of DTCs, control module name)
The sorting can be changed in this sequence. The names of the buttons will change accordingly.
Note:
Clicking the Change sorting button displays the DTC descending button. Clicking the DTC descending button
displays control modules with the most DTC entries at the beginning of the table. This is helpful for a quick
overview of the control modules with DTCs.
94
Diagnosis Operating Mode
An additional option for sorting the table contents is clicking on the column header in the table. Clicking the
Address column header once displays the diagnostic addresses in ascending order. Clicking the header again
displays the numbers in descending order. Clicking the column header a third time shows the diagnostic addresses
unsorted in the order in which they were originally read. The sorting process is the same for the DTC and Name
columns.
This button switches the view between actual installation and maximum installation.
Actual installation: clicking this button displays only the control modules that are actually installed.
Maximum installation:
clicking this button displays all of the possible control modules for that vehicle model.
6.2.6.2. Network diagram
Once the control module reading begins, the vehicle networking diagram can be displayed on the Control modules
tab.
Figure 6.46. Networking diagram view
Clicking on the Networking diagram tab opens an illustrated overview of the current networking diagram in the
overall view.
95
Diagnosis Operating Mode
The Networking diagram shows the networking between control modules in the maximum installation. Clicking
on an illustrated control module displays a note under the Networking diagram that indicates the control module
system name.
There are several navigation buttons under the Networking diagram.
In order from left to right:
Change to networking diagram overall view
After zooming in, this button returns to the networking diagram overview.
Zooming in on the networking diagram
Each click on the button zooms in on the Networking diagram and shows more detail. If the button is not
active, the view of the networking diagram has zoomed in as much as possible.
Zooming out in the networking diagram
Each click on the button zooms out of the Networking diagram. This button is not active when the networking diagram is in the overall view.
Scrolling in the networking diagram
Clicking the button moves the Networking diagram.
After activating the button, click any location on the Networking diagram and drag it in the desired direction with
your finger, if using the touchscreen. When using the mouse, press and hold the left mouse button while dragging
it in to the desired location on the Networking diagram.
This button is not active when the networking diagram is in the overall view.
Note:
Double clicking on the touchscreen or the left mouse button is only possible when the
vated.
symbol is not acti-
The illustration of the Control modules can be used to determine the condition of each individual Control module.
96
Diagnosis Operating Mode
The control module was not identified and is part of the maximum installation.
The control module was found and identified and does not contain any DTC entries.
DTC entries were found for the control module.
The control module was not identified but was manually entered as "installed" (see below).
Figure 6.47. Examples of Control Module Graphic Display
Clicking and holding for approximately 1 second or right-clicking on a control module in the networking diagram or control module list opens another button bar. The buttons available there depend on the selected control
module.
Figure 6.48. Buttons for Individual Control Modules
97
Diagnosis Operating Mode
The following buttons are available above the context menu:
Figure 6.49. Context Menu (Control Module Buttons)
When you click on the Measurement button, Offboard Diagnostic Information System Service changes
to the Measurement mode.
Note:
Refer to "Measurement".
Clicking on the Identify control modules button will perform a preferred control module or later control
module identification, depending on when the button is clicked:
•
the preferred identification is performed during automatic control module identification. It changes the
sequence of automatic control module identification.
•
the later identification is performed after control module identification is complete. An unknown and
unidentified control module is manually entered as installed afterward. If the entry is made by confirming the
message from Offboard Diagnostic Information System Service, the control module is entered as manually
installed.
Figure 6.50. Entering a Control Module as Installed
Yes: the control module is marked entered as entered manually and shown in the networking diagram and the
control module list.
98
Diagnosis Operating Mode
No: the control module is marked not entered as installed.
If a control module was manually entered as installed later because it could not be identified automatically, it
will display in the control module list and the networking plan in italic font.
Figure 6.51. Italic display of control modules manually entered "as installed"
The button Select version allows you to select a version of the control module if more than one version exists.
The possible control module versions are displayed.
The versions may change at any time.
Figure 6.52. "Select version" Dialog
Select: after selecting the control module version and clicking this button to confirm, the control module list, the
DTC memory and the test plan are updated automatically.
Close: clicking this button closes the form without selecting a version.
The version selection is only available for control modules that have already been identified or entered manually.
Note:
Refer to the chapter "Guided Fault Finding - Calculate Test Plan
If you click the Read DTC memory again button, only the DTC memory entries for the selected control
module are read again. The test plan updates automatically.
99
Diagnosis Operating Mode
To read the DTC memory again for all identified control modules, click the Read all DTC memories button.
This also updates the test plan.
After identifying a control module, the Guided Functions button can open a selection that contains all function
tests for this control module such as output diagnostic test mode for the crash signal. When a function test is
selected and the Perform button is clicked, the program is performed on the Operation tab.
Figure 6.53. Selecting control module guided functions
Perform: Clicking this button performs the marked Guided Function in the Operation tab.
Cancel: The Guided Functions window closes.
The OBD button and
this manual.
the Vehicle self-diagnosis button are described in detail in the "OBD" chapter of
Cross-reference:
Also refer to "On Board Diagnostic".
100
Diagnosis Operating Mode
6.2.6.3. DTC memory
The available DTC memory for each control module can be viewed in the DTC memory view. This list only
contains control modules that have a DTC memory entry.
Figure 6.54. DTC memory entries view
Clicking on the DTC memory list tab
memory entries.
on the Control modules tab
The entries are closed first, the list indicates the control modules.
101
lists the control modules with DTC
Diagnosis Operating Mode
Figure 6.55. Opening a DTC memory entry
Double-click to open or close a DTC memory entry. If it is marked with a plus sign (+) or a negative sign (-), it
can also be opened or closed by clicking on the plus or minus sign.
The following picture illustrates the details about the control module.
Figure 6.56. Information about a DTC memory entry
The following information is available in the DTC memory entry as indicated by the numbers:
Incident code
102
Diagnosis Operating Mode
Symptom code
Incident location
Symptom
Memory status
The view can be switched between the following two views using the Display button:
the standard ambient conditions are shown
the standard ambient conditions are not shown
.
The standard ambient conditions provides information about:
•
Status
•
Date and time of the entry
•
Mileage
•
Priority
•
Frequency counter
•
Elimination counter / driving cycle
The sequence in an entry can be changed by clicking the Sorting button within the DTC memory
entry. The active sorting sequence is grayed out in the menu.
Figure 6.57. Sorting DTC List
Mileage: clicking this button sorts the content in ascending order according to mileage.
Priority: this button displays the content according to its importance.
Error counter: clicking this button sorts the content according to the error counter (how often the event was
detected).
103
Diagnosis Operating Mode
Status: this button sorts the content according to the status of the error.
sporadic/static: this button lists the faults entered as sporadic at the top of the list.
Cross-reference:
Refer to "Control Module List".
Clicking and holding approximately one second or right-clicking on a control module opens the control module
button bar as in the control module context menu.
Figure 6.58. Context menu in the DTC memory view
The context menu buttons are described in more detail in the Networking diagram chapter.
Note:
Refer to "Networking Diagram".
104
Diagnosis Operating Mode
6.2.6.4. Equipment list
The equipment lists shows the characteristics of the equipment specified for the vehicle. These are determined
based on the equipment network, which is specified after confirming the basic characteristic dialog.
Figure 6.59. Equipment list view
Clicking on the Equipment list tab
on the Control modules tab
and indicates if they are installed or not.
displays the equipment characteristics
Equipment characteristics can be displayed as follows:
not installed and only one version available (gray font)
installed
not installed and multiple versions available (gray font and individual versions are separated with |)
When starting diagnostic entry, all equipment characteristics are shown as not installed.
To mark an equipment characteristic as installed and to select a version, if applicable, click the Select version
button in the context menu for the equipment characteristic.
105
Diagnosis Operating Mode
Figure 6.60. Equipment list context menu
A window opens where the desired version and installation status can be selected.
Figure 6.61. Select version
The entry at the very top of the list is always not installed.If this one is selected, then the installation status of
the equipment changes to not installed.
Selecting a version changes the installation status to installed.
If the dialog is opened when a version is already selected, this version will be marked with a * in front of it.
Select: Accepts the selected version and sets the installation status to installed, or not installed if this list entry
had already been selected. The button is only active once a selection is made.
Close: Closes the dialog and discards the selection.
The test plan is updated automatically each time the installation status or an equipment characteristics for an
installed version is changed.
106
Diagnosis Operating Mode
6.2.7. Starting Guided Fault Finding (GFF)
Guided Fault Finding can be started once control module identification is complete.
Figure 6.62. Starting GFF Section
Offboard Diagnostic Information System Service opens the Diagnostic entry confirmation window with the
note that Guided Fault Finding (GFF) should be started.
Figure 6.63. Starting Guided Fault Finding
OK: confirming with this button starts Guided Fault Finding.
The next chapter describes the procedures that Offboard Diagnostic Information System Service performs during Guided Fault Finding in more detail.
Note:
Refer to "Working with GFF".
107
Diagnosis Operating Mode
Notice:
If control modules currently installed in the vehicle were not identified, it is possible to enter them in the networking diagram or in the control module list as installed, select a version, if necessary, and then add as a
diagnostic object in component selection.
Note:
See "Identifying Control Modules"
Note:
Refer to "Selecting Versions".
Note:
Refer to "Component Selection"
6.3. Test Plan and Special Functions
In the test plan and special functions section, the start module and traversal tests are completed and the test
plan is calculated automatically and adapted manually using DISS and TSB, if needed. The test plan and special
functions for Guided Fault Finding are available at the end of this section.
Figure 6.64. Test Plan and Special Functions Section
108
Diagnosis Operating Mode
6.3.1. Start Module, Traversal Test, Test Plan Calculation
This section describes how Offboard Diagnostic Information System Service performs the start module and
traversal test and then calculates the test plan.
Figure 6.65. Start Module, Traversal Test, Test Plan Calculation Section
When Guided Fault Finding starts, start module and traversal tests are performed on the Operation tab. These tests
run in the background.
In a traversal test, the control module versions are set based on the control module information that was read out.
If a version cannot be identified automatically or a vehicle-specific attribute should be entered, a message with a
selection will appear. If there are several versions of individual control modules within the traversal test, a dialog
opens to select a version.
Figure 6.66. Version Selection View
To select a control module version, click next to the respective control module in the Version field. A button
appears that is used to open the menu in order to select the version.
Set version: the selected control module versions are accepted.
After setting the control module versions, the preparation of the test plan begins.
109
Diagnosis Operating Mode
The automatic preparation of the test plan and the sequence of the test programs depend on the DTC entries that
were read from the control modules, from Technical Service Bulletins (TSBs) and from customer comments during
vehicle drop-off, which are available in coded form. These coded customer comments consist of malfunction
objects (for example, components), malfunction types (for example, "it rattles") and conditions (for example,
temperature).
The test programs in the test plan are sorted according to their chances of success in Guided Fault Finding, from
greatest to lowest.
There are several methods for creating a test plan and updating it. For additional information on creating a test
plan, refer to the following chapters:
Creating a test plan during diagnostic entrance.
Cross-reference:
Refer to "Diagnostic entrance"
Creating a test plan by selecting the version
Note:
Refer to the chapter "Diagnostic Entrance Version Button".
Updating the test plan by reading the DTC memory again.
Note:
Refer to the chapter "Diagnostic Entrance DTC memory.
Updating a test plan using DISS / TSB.
Note:
Refer to "Guided Fault Finding DISS/TSB".
110
Diagnosis Operating Mode
6.3.2. DISS / TSB
This section describes how the creation of the test plan can be affected by creating and including concerns.
Figure 6.67. DISS / TSB Section
The Offboard Diagnostic Information System Service changes automatically into the DISS tab in the background after the test plan is established.
Figure 6.68. View inside the DISS tab after the diagnostic entrance
111
Diagnosis Operating Mode
All of the DISS concerns from ElsaPro for the selected order are listed. Manual concerns can also be created using
the coding assistant. The Guided Fault Finding test plan can be affected by these concerns.
Figure 6.69. Table with DISS Concerns
The table of DISS complaints has four columns:
1. DISS Concern ID: the identification number for a concern.
2. Customer comment: that is the concern in the words of the customer as recorded at the time the order was
created.
3. Customer code: that is the text coding of the customer comment.
4. TSB from DISS: the number of the TSB to which the concern is assigned by the DISS system.
There are two possible categories for DISS concerns:
1. Concerns from the DISS system: this concerns provides all of the DISS information from the order that is
currently being used from ElsaPro and is called up automatically in the background at the start of the diagnostic
selection when the order is selected. An online connection with login to the group systems is required for the list
of concerns from DISS.
2. Manual concerns: these concerns are entered manually and shown in the customer code column. The DISS
concern ID is always "manual". The two right columns have no information. These concerns are also available
offline with no login to the group system.
The coding assistance produces a manual complain. The dialog window coding assistant opens with a click on
the coding... button of a marked empty complaint line.
112
Diagnosis Operating Mode
Figure 6.70. Coding assistance dialog window
Offboard Diagnostic Information System Service adds a new row for a manual concern each time a manual
code is added to the concern table.
Note:
The procedure for using the coding assistant is described in more detail in "Coding Assistant".
Functions to display TSBs:
The function knobs are at the bottom of the complaint list, can be used to select a marked complaint in the customer
code overview or can be used to expand the test plan, TSB lists from the DISS system or to access the individual
complaint TSB in the TSB tab.
These function buttons are activated only with the current DISS complaints.
113
Diagnosis Operating Mode
Figure 6.71. Function buttons in the DISS tab
Coding...: all customer coding details are displayed in the table in the customer coding overview window of the
highlighted complaint.
If this button is used with a selected empty line, the window opens with coding assistance.
Supplement test plan...: the Transfer diagnostic objects to test plan window opens, in which associated diagnostic objects are displayed with available codes. These diagnostic objects can be added to the test plan. Not all
of the concerns have associated diagnostic objects. If that is the case, the test plan cannot be supplemented. A
detailed description of this function is provided later in this section.
Note:
Refer to "Supplementing the Test Plan".
Display TSB list: all relevant TSBs, if applicable, for the customer coding of a selected complaint are displayed.
The application changes automatically in the TSB tab and open the Display TSBs window in the TSB list tab
view. This function is only available for concerns from the DISS system and for customer codes that have all
mandatory fields filled in. A login to the group systems is required for DISS access.
114
Diagnosis Operating Mode
Figure 6.72. TSB tab view
The TSB tab displays the same table of complaints as the DISS tab with an additional columnTSB manual, in
which the TSBs entered manually are displayed.
Supplement test plan: opens the Transfer diagnostic objects to test plan window.
Display TSB: opens the Display TSB window in the TSB number tab view. The TSB for the selected complaint
is displayed.
Figure 6.73. Showing a Selected TSB Number
It is possible to access and view other TSBs from ElsaPro. Enter the TSB number in the TSB number field and
press the Display button.
115
Diagnosis Operating Mode
Figure 6.74. Entering a TSB Manually
Manually adding a TSB:
It is possible to enter the TSB number in the TSB Manual column using the TSB number field in both TSB list
and TSB number tabs within the Display TSB dialog window. Enter the TSB number in the field and then click
on the Accept button as a manual TSB assigned to the highlighted complaint. The Accept button is activated only
when there is a new TSB number. All the manually entered TSBs are listed in the drop down list.
Supplement test plan:
If the supplement test plan button for a highlighted complaint was pressed in the DISS or TSB tab, the Transfer
diagnostic objects to test plan dialog opens.
Figure 6.75. Transfer diagnostic object to test plan
This dialog lists all of the complete customer codes that belong to the current order, including those added manually. The upper half of the dialog lists the customer codes and their TSBs from DISS. If available, the lower half
lists the diagnostic objects associated with the selected TSB.
The customer code/TSB that was opened using the Supplement test plan function is selected automatically. The
diagnostic objects for this selected customer code/TSB are also determined automatically.
The diagnostic objects can be selected or deselected individually or all at once by clicking the checkbox in the
left column.
Select all: all diagnostic objects are selected.
Deselect all: all diagnostic objects are deselected.
116
Diagnosis Operating Mode
Transfer to test plan: clicking this button transfers the diagnostic objects for the selected customer codes/TSBs
to the test plan calculation. Customer codes/TSBs and their diagnostic objects that were already transferred to the
test plan are grayed out in the list view. They cannot be transferred to the test plan again.
Close: no diagnostic objects are transferred. The dialog window is closed.
Diagnostic objects are only displayed for the marked customer codes/TSBs.
Figure 6.76. Deselected Customer Code
In the illustration above, no customer code is selected, which is why no diagnostic objects are displayed in the
lower list.
Close: The dialog window is closed.
Notice:
Test programs that were transferred to the test plan as a result of reevaluating the added diagnostic objects can
only be removed again in the Test plan tab.
Note:
Refer to "Working with GFF".
The Complete view can be accessed for the marked customer codes using the context menu for the right mouse
button.
117
Diagnosis Operating Mode
Figure 6.77. Selecting the Complete View
This function is the same as the Complete customer code function described above.
Close: The dialog window is closed.
Figure 6.78. Complete View of a Customer Code
In the Customer code complete view, all coding levels from the coding assistant are displayed with available
entries.
Close: The dialog window is closed.
Test plan creation can be completed after editing the DISS concerns.
118
Diagnosis Operating Mode
6.3.2.1. Coding assistant
The coding assistant is used as follow:
Figure 6.79. Coding assistant
The customer code fields can be filled in using the coding assistant. To simplify the process, the coding assistant
indicates the required coding fields step-by-step in the correct order with a green border.
The coding levels to be filled in are located on the left as buttons, namely groups and subgroups of Components/Functions, Types of Complaints as well as Constraints and General Constraints. Fields are located next
to the buttons, in which the selected coded values are displayed. Once an entry is made in a coding field, all of the
buttons for the secondary fields that can now be filled are activated.
In the right window, suitable values are displayed for the green-bordered buttons. These values can be selected by
clicking. The active button is shown as a heading. The Constraints button is shown at the top of illustration.
Constraints and General constraints are marked and can be added or removed by clicking on the arrow buttons
<< or >> .
Depending on the hints provided by the coding assistant, it is also possible to click on an activated button on the
left side, which is then shown with a green border and can be filled. After filling the field, the coding assistant
continues providing assistance as described above.
Notice:
Fields marked with a * at the right are required fields that must be filled out in order to expand the test plan
with manual customer codes.
The General constraints field contains constraints that are not directly allocated to the customer code. When it
is filled, the result is that no diagnostic objects can be found for the current customer code.
119
Diagnosis Operating Mode
6.3.3. Special functions
In addition to the Guided Fault Finding test plan, there are additional test programs with the same name in the
Special functions tab.
Special functions are vehicle-specific test programs. They are not selected within diagnostic entrance through
vehicle basic features or control modules. They are made available from the database for individual vehicles.
Clicking the special functions tab in Diagnosis mode displays the tests that are available for the entire vehicle.
Notice:
In Flashing mode, the available flash programs for the vehicle are listed in the Special functions tab after the
vehicle and control module identification. There is no test plan in this mode.
Note:
Refer to "Working with flash programs".
Special functions in Diagnosis mode include coding the immobilizer and transport protection, for example.
120
Diagnosis Operating Mode
Figure 6.80. Special Functions View
There are two columns in this view. The Tests column contains all of the test programs available for the vehicle.
The Status column indicates the status of the test program.
The test programs are grouped by theme.
Note:
Refer to "Working with GFF".
Perform test: the highlighted test program is performed. Offboard Diagnostic Information System Service
switches to the Operation tab.
Show documents: the documents allocated to the vehicle are displayed. Offboard Diagnostic Information System Service switches to the Information mode.
121
Diagnosis Operating Mode
6.4. Working with GFF
The completion of GFF tests is the focus of the Working with GFF section.
Figure 6.81. Working with GFF Section
After creating the test plan, you can switch to the list of test programs by licking on the active Test plan tab.
122
Diagnosis Operating Mode
Figure 6.82. Test Plan View
The Test plan tab contains a table with available tests. This table has two columns.
Status: this column indicates the status of the test by means of a symbol.
This symbol indicates that the status is "Test not performed".
This symbol indicates that the status is "OK". This test was successful.
This symbol indicates that the user cancelled a test.
This symbol indicates that the status is "not OK". The test failed.
This symbol indicates that the status of the program could not be determined.
This symbol indicates that the diagnosis was completed and the component was repaired.
Tests: this column contains the possible test programs sorted according to their chance of success.
Perform test: this button is used to start the highlighted test. Offboard Diagnostic Information System Service
then switches to the Operation tab.
Documents: documents for the test plan or for a marked test program can be displayed using this button. Offboard
Diagnostic Information System Service then switches to the Information tab.
123
Diagnosis Operating Mode
Select own test: this button opens the Tests overview window, in which test programs for individual vehicle
diagnostic objects can be added to the test plan.
Remove: test programs that were added manually can be removed from the test plan using this button.
Note:
additional explanations.
There are additional explanations about the documents made available in Guided Fault Finding in the chapter
"Information Mode/Documents'...".
To select a test program (test), either click on the text line marked in gray or on the appropriate symbol at the left.
Figure 6.83. Activating a test in the test plan
The Perform test screen button becomes active after clicking.
The content of the selected test program is displayed under the list as an explanation.
Perform test: clicking this screen button starts the test program.
Offboard Diagnostic Information System Service now switches to the Operation tab, which which instructions
and input options for the test program that has started are displayed.
124
Diagnosis Operating Mode
Figure 6.84. Test view in the Operation tab
The name of the active test program is shown in the upper left ("Error in ECM" in the example above), with the
name of the current step below it ("Reporting" in the example above).
OK/Continue: this screen button confirms a message and moves to the next test step.
Cancel test: if the test is ended early by clicking on this screen button, the cancelled test program is identified
with the symbol
on the Test plan tab under the Status column.
Help: this screen button works when help information is available for a test program.
The navigation screen buttons under the messages can be used to navigate within the individual messages.
Back to first message. This screen button works only if there are several messages.
Displays the last available message. This screen button works only if there are several messages.
One message back
One message forward/next message
125
Diagnosis Operating Mode
The fonts size inside the message and instruction window can be changed using both screen buttons at the bottom
on the left side. Repeatedly pressing the buttons on the screen makes the font size larger or smaller (maximum three
sizes). Any changes to the font size will remain after closing Offboard Diagnostic Information System Service.
Makes the font size larger. The screen button turns off once the maximum font size is reached.
Makes the font size smaller. The screen button deactivates once the minimum font size is reached.
The Message and instruction window is located in the center of the operation view.
Figure 6.85. Message and Instruction Window in the Test Procedure
The test procedure message window contains information and instructions for the individual test steps.
The individual steps in the active test program that have already been performed are listed in the left area.
126
Diagnosis Operating Mode
Figure 6.86. Sequence of Steps in the Test Procedure
The current test step is shown with a blue border.
Click the navigation screen buttons described above or click the individual test steps on the left near the fault
finding notes (for example: Procedure, Model selection, Delay, DTC evaluation, etc.) at any time to display the
completed messages and view the fault finding tips.
A test program can provide alternative test steps for selection.
127
Diagnosis Operating Mode
Figure 6.87. Screen Buttons to Select Alternate Test Steps
In the example shown above, the desired campaign can be selected with the numbered screen buttons (-1- and -2here). If the screen button -2- is clicked in the example, the next instruction for correcting the fault is displayed.
Figure 6.88. Display of Selected Test Steps
In this example, the -2- screen button was selected, which is indicated by the -2- under the possible selections.
A test program can prompt decisions by means of screen buttons.
128
Diagnosis Operating Mode
Figure 6.89. Decision screen buttons in the test program
In the example above, the question asked in the test program must be answered by clicking on Yes or No.
The screen buttons shown here may have different names. The names depend on the content of the test program.
The test program may also prompt you to enter values using the keyboard. In this case, an input window will open
instead of the screen button.
6.4.1. Measured values
In some test programs, it is necessary to read the measurements from one or more control modules. In this case,
the user will be requested to select the measurements. This takes place in the following dialog:
Figure 6.90. Measurement selection
All available measurements appear in the table.
129
Diagnosis Operating Mode
Selection: Click the box to select or deselect a measurement.
ID: The measurement ID.
Measurement: The name of the measurement.
Click on the column header to sort the table by ID or Measurement.
Select all: Select all measurements in the table. The screen button is off when all the measurements are selected.
Deselect all: Deselect all measurements in the table. The screen button is off when no measurements are selected.
OK: The dialog closes and the selected measurements are incorporated into the test program.
Cancel: Closes the dialog without saving the measurements.
The measurements read by the test program are then displayed in a table.
Figure 6.91. Measurements display
Address: The control module address that is processing the measurement.
Name: The measurement name.
Value: the measured value.
Unit: The measured value unit.
Target value: The expected value or a range of values in which the measurement may be found.
Click on the column header to sort the table by Address or Name.
Begin Updating: Begins updating the measurements periodically. The column header changes to Stop Updating
while the measurement is running.
Stop Updating: Stops the measurement currently running.
Description: Opens a new dialog with a description of the measurement.
Add to the test plan: Adds the selected measurement to the test plan.
Ok: Ends the dialog and stops the measurement.
When a measurement is selected and the description screen button has been activated, a dialog window with the
exact description of the measurement will open:
130
Diagnosis Operating Mode
Figure 6.92. Description of a measurement
6.4.2. Gateway coding
If a program for Gateway coding is accessed, the test sequence will have a few special instructions. The following
describes these.
The test program determines which control module is already coded in Gateway and which additional control
modules are available for selection. These are shown to the user in a dialog.
131
Diagnosis Operating Mode
Figure 6.93. Selection of control module to be coded
All control modules are listed in the left column, which from the data were identified and are still not marked in
Gateway as installed.
The control modules in the right column are marked as in Gateway as installed.
describes the control modules in the right list.
describes the control modules in the left list.
OK: Coding with the current selection continues.
Cancel: the selection is discarded and coding is cancelled.
If you confirm the dialog with OK, the selection is shown in a list. The control modules coded or to be coded
appear in front of the not coded ones.
132
Diagnosis Operating Mode
Figure 6.94. Display of the coded/not coded control modules in the test program
If you continue the test program with End/Continue, then additional decisions for special coding must be made
for some vehicles. You will be asked for vehicle brand, vehicle version, the number of door and if the vehicle has
right-hand or left-hand drive. This information is already in the Gateway control module and can be changed by
the user. The information read from the Gateway is framed in blue.
This inquiry for this information is also constructed the same and displays the brand as shown in the example:
Figure 6.95. Special coding - brand selection
133
Diagnosis Operating Mode
Clicking on the information to be coded open the window with the next inquiry.
After all the decisions for special coding are made, the user must confirm one more time that the Gateway coding
should be written now:
Figure 6.96. Inquiry before writing the Gateway coding
If this test step is answered with yew, then the coding will be written into the control module.
With No, the coding is cancelled. If the selection of coded control modules was changed earlier, then the user is
instructed to confirm the cancellation.
134
Diagnosis Operating Mode
Figure 6.97. Inquiry with changed coding
Clicking on yes cancels the coding.
With No the new coding is written into the Gateway control module.
135
Diagnosis Operating Mode
6.4.3. Documents
Documents can also be supplied in the test programs for individual test steps.
Figure 6.98. Function descriptions in the test program
The documents are accessed using the corresponding buttons, for example Function description. The name of
the document, and therefore the name of the button, depends on the test program.
Clicking the Function description button displays that document.
This pertains only to documents that are integrated into the test programs.
Local and global documents can be allocated to a test program. Local documents pertain to individual test steps.
Global documents pertain to the entire test program.
136
Diagnosis Operating Mode
Figure 6.99. Local and Global Documents in the Test Program
If several local and global documents are integrated into a test program, all of the local documents will be listed
in an upper block and all of the global documents in a lower block. Both blocks are clearly separated from one
another. Documents with the same name are numbered in both blocks.
Note:
For additional information on the documents, refer to "Documents".
137
Diagnosis Operating Mode
Figure 6.100. Leaving Document View
The documents are displayed in the display and message window in the Operation view.
Clicking this button will switch from the document view back to the test step in the test program in order
to continue with the test.
After the test program is completed, clicking the OK/Continue button ends the test. Offboard Diagnostic Information System Service switches back to the table view in the Test plan tab and the next tests can begin.
138
Diagnosis Operating Mode
6.4.4. Test Verification
A test program can be performed more than once by selecting it and starting the test again using the Perform test
button. If the test program was completed successfully (green check mark in the test plan view), a message will
appear asking if a Verification should be performed.
The verification mode allows you to check entries other than the ones in the previous test in order to either confirm
or disprove the earlier results (verification).
Figure 6.101. Verification mode inquiry
Yes: clicking this button starts a test again that was already performed successfully. Depending on the type of test,
it can be performed again with different parameters or selections.
No: clicking this button performs successful test again using the same parameters.
139
Diagnosis Operating Mode
6.4.5. Component selection
In the Test plan tab, it is possible to add additional tests for vehicle components or documents to the test plan
manually.
Click the Select own test... button in the Test plan tab to do this.
The Test overview window appears, which displays the vehicle diagnostic objects. The desired test or document
can be selected here from the menu tree structure.
Figure 6.102. Test selection window
Click the plus symbol ( + ) to navigate deeper into the structure. Documents can also be added to the test plan in
addition to components. Selected documents are listed like test programs.
Attach to test plan: Once the required test for a component or document is selected, it is added by clicking this
button. A test program or document can also be selected by double-clicking.
Additional components or documents can then be added.
Manually added tests are located at the end of the test plan.
This test programs and documents can be removed from the test plan using the Remove button in the Test plan tab.
You can also search for a testing using the search function by clicking the Search symbol.
Note:
Also refer to the chapter "Search function".
Close: The window is closed.
140
Diagnosis Operating Mode
The test program for the manually added components and documents can now be started by clicking the Perform
test button.
Note:
Tests and documents that were added to the test plan manually are shown in light blue.
Notice:
Components that were added to the test plan manually but not tested with the Perform test button are NOT
transferred when the test plan is recalculated.
6.5. End diagnosis
In the end diagnosis section, the diagnostic session is completed with the clearing of the DTC memory, the
performing of end modules and the option for feedback.
Figure 6.103. End Diagnosis Section
To end diagnosis, click the End diagnosis button on the Control modules tab.
141
Diagnosis Operating Mode
Figure 6.104. End diagnosis
Offboard Diagnostic Information System Service then opens the End diagnosis confirmation window with the
question Do you want to end the current diagnostic session?
Yes: the diagnosis is ended.
No: diagnosis is not ended. It continues with no changes.
After selecting Yes, Offboard Diagnostic Information System Service then asks in the Exit GFF: Decision to
end GFF? window if it should continue Guided Fault Finding. If all of the tests listed in the test plan were not
performed, the window contains a message indicating that the test plan was not completed.
Figure 6.105. Ending fault finding
Yes: Guided Fault Finding continues and does not end.
142
Diagnosis Operating Mode
No: Guided Fault Finding is ended and the system continues exiting the diagnosis.
If the vehicle was switched during the diagnostic session, Offboard Diagnostic Information System Service
asks if the repair should be continued on the connected vehicle or if the session in progress should be cancelled.
Figure 6.106. Erasing the DTC memory
Continue: The system continues exiting the diagnosis.
Cancel: Clicking this button cancels the diagnostic exit and continues the repair on the connected vehicle.
If a new DTC memory check produced new or different results, Offboard Diagnostic Information System Service asks if a new test plan should be calculated.
Figure 6.107. Erasing the DTC memory
Yes: clicking on this button creates the test plan again and continues Guided Fault Finding.
No: no new test plan is created and the system continues exiting Guided Fault Finding.
In the next step when ending diagnosis, the end module is performed. These programs are based on the vehicle
type that was diagnosed and its equipment versions. There is no set group of end module programs. Diagnostic
editors create them individually for the available vehicle types. The sequence in which they run is also not the
same for all vehicles. Likewise, the program sequence may also be very different.
The end module programs are listed in the Operation tab as with guided fault finding and decisions may have to
be made or questions may have to be answered, depending on the program.
143
Diagnosis Operating Mode
Notice:
One exception is the readiness code program. This program is a fixed component of Offboard Diagnostic
Information System Service and is always performed when ending Guided Fault Finding.
For diesel vehicles with diesel particulate filter, the readiness code program is an end module that is created by
diagnostic editors. Because of this, the program sequence may differ for diesel vehicles.
Figure 6.108. Performing the readiness code program
Yes: clicking this button performs the readiness code test program.
No: the readiness code program is not performed.
In the last program in the Operation tab, you must decide if the diagnostic log will be sent to Support.
144
Diagnosis Operating Mode
Figure 6.109. Send diagnostic log?
Send: the diagnostic log will be sent to Support automatically as long as a network connection is available. If
there is currently no network connection, the diagnostic log will be saved and will be sent the next time Offboard
Diagnostic Information System Service is started.
Skip: the diagnostic log is not sent.
Exit GFF: print/save diagnostic logdialog comes after the end module. In this dialog, you can choose to print
or save a diagnostic log.
Figure 6.110. Print/save diagnostic log
Print: Offboard Diagnostic Information System Service opens the Select diagnostic log dialog. After selecting
the log type, which can also be cancelled, a formatted diagnostic log is sent to the standard Windows printer driver.
This will open and it can be printed with all known Windows settings. You must confirm with OK to end the print
process. The Exit GFF: print/save diagnostic log dialog then opens.
145
Diagnosis Operating Mode
Save: Offboard Diagnostic Information System Service opens the Select diagnostic log dialog. After selecting
the log type, the Windows save dialog opens for saving the log. After saving or cancelling the save, the Exit GFF:
print/save diagnostic log dialog opens again.
Figure 6.111. Select diagnostic log
The OBD log can be selected here in addition to the desired version of the diagnostic log. If OBD log is checked
off, both the diagnostic log and the OBD log will be printed/saved.
Ok: Transfers the desired log to the print or save function.
Cancel: Returns to the previous dialog with no action.
Cross-reference:
Refer to the chapter "Additional Program Functions/Logs" for additional information on selecting the log type
and saving the log.
Continue Offboard Diagnostic Information System Service continues exiting GFF.
To conclude, Offboard Diagnostic Information System Service opens the Send support request dialog. Here
it is again possible to send the diagnostic log with a support request.
146
Diagnosis Operating Mode
Figure 6.112. Support request
Cancel: the support request is cancelled and is not sent.
Send support request: an automatic support request is sent with the diagnostic log.
If there are errors in the program sequence, you can also edit the support request and add your own comments
and screenshots.
Add comments: the feedback dialog opens for further editing. This button is only available when ending the
diagnostic session if Offboard Diagnostic Information System has detected errors in the program sequence.
The Feedback chapter provides a more detailed description of the support request.
Cross-reference:
Refer to the chapter "Feedback".
This ends the diagnostic session. Offboard Diagnostic Information System Service is in the Diagnosis mode
start view.
147
Diagnosis Operating Mode
6.6. Quick entrance
A diagnostic entrance without Guided Fault Finding is also called diagnostics quick entrance. You can work
in this mode only when there is no order. The self-diagnosis functions are available. In addition to this, Guided
Functions and Special Functions can be performed.
In most cases the test plan is not available and its tab is not active.
To perform Guided Functions, it is necessary to select a control module in the list of control modules or in the
network plan and then click on Guided Functions in the context menu.
Note:
See the description of Guided Functions in "Network Plan".
Since the knowledge base during the diagnostic quick entrance is only partially filtered and not all attributes of the
equipment network are known, then the note must be caught up in some cases in order to determine the Guided
Functions belong to a control module.
A dialog is displayed which requires the user to complete the missing equipment characteristics. The control
module can tell which version is installed, or, if the control module is installed or not.
Figure 6.113. Manual control module selection
The following is an example of a dialog. Which available characteristics that are actually displayed depends on
the current equipment network and the on the diagnostic objects contained in the knowledge base.
OK: Accepts the selection and ends the dialog.
GFF programs may contain Guided Functions and Special Functions, which transmit diagnostic objects relevant
to the vehicle. If this is the case, then the test plan tab is active, and if necessary, the new diagnostic objects are
added there. They can then be performed as the other tests.
The GFF program sometimes needs more information, which was not transmitted completely during a diagnostics
quick entrance, about the equipment network in order to transmit the diagnostic objects.
In this case, the dialog described above for manually selecting a control module is called up.
Using this information determined from there, the diagnostic objects relevant to the vehicle are transmitted and
are displayed in the test plan tab.
148
Diagnosis Operating Mode
Figure 6.114. Quick entrance test plan
Only the Perform test... screen button is available in this mode. The test is executed just like GFF diagnostic
programs when the screen button is pressed.
Note:
Refer to "Working with GFF".
The test programs performed previously will be checked again after the diagnostic session is over if quick entrance
was used exclusively. If the check is positive, then a dialog will be asked to save and print the diagnostic log.
Figure 6.115. Print/save diagnostic log
Print: The formatted diagnostic log is sent to the Windows printer and can be printed there. The diagnostic log
print/save dialog will appear again at the end.
149
Diagnosis Operating Mode
Save: The Windows save dialog opens and then the diagnostic log can be saved. The diagnostic log print/save
dialog will appear again at the end.
Next: The diagnostic exit continues.
Note:
Refer to the GFF Exit: diagnostic log print/save dialog in "End diagnostics".
150
Chapter 7. OBD mode
The following chapters describe under which conditions control module self diagnosis functions in addition to
Guided Fault Finding are available, how the self diagnosis functions are called up and what the individual functions
are able to do.
Self diagnosis gives the user the opportunity to access individual diagnostic functions for the control module or
vehicle. Self diagnosis is generally used when:
•
there is no GFF for the vehicle (very old or very new model),
•
there is no GFF for that particular problem,
•
the GFF suggests using self diagnosis.
In contrast to GFF, the user must interpret the results.
7.1. Start self diagnosis
Figure 7.1. OBD entry start window
Clicking on Start OBD starts the OBD entry.
The vehicle VIN is found here and is used to identify the vehicle.
If a clear identification is not possible, the basic information dialog opens, in which the user must fill in the missing
information.
151
OBD mode
Note:
See "Basic Information Dialog"
Then the list of devices is read and displayed in the Results view.
The results views of OBD are displayed as in the example Adaptation as follows.
The view is divided into three areas.
The actual OBD function is performed in the main area.
The tabs for the different OBD functions are listed under the main area. Here, the user can move between the
different tabs or can close them by clicking on
.
With control module-specific OBD functions, the name of the control module is displayed here. If the name
is too long can cannot be shown completely in the field, then clicking on the field shows the complete name.
The move quickly to a different OBD function for the same control module, use the list to do this. All control
module-specific OBD functions are listed in this list. After selecting a function, click on it
show it in its own tab.
152
to start it and
OBD mode
7.2. Self Diagnosis General Information
7.2.1. Starting OBD from other operating modes
After entering using OBD operating mode, there are two additional possibilities, to perform BOC functions in
Offboard Diagnostic Information System Service:
1.
A diagnosis is performed with Guided Fault Finding without an order.
2.
The diagnostic entry was started as quick entry with out the option work with Guided Fault Finding.
Note:
In both cases, an additional entry into the Guided Fault Finding in the Control modules
using this screen button is possible. This starts automatic control module identification and Guided Fault Finding.
Note:
Refer to "Diagnostic Entry" and "Networking Diagram".
7.2.2. Accessing OBD functions
OBD functions can be accessed from the control module list for from the network plan.
Click on the control module with the left mouse button for longer than 1 second or with the right mouse button.
A context menu with the OBD buttons opens. Some screen buttons are deactivated depending the operating mode
(OBD or diagnostics).
Figure 7.2. Starting OBD
153
OBD mode
•
Control module self diagnosis: clicking this button opens the Self diagnosis functions selection window
with self diagnosis functions for the marked control module.
Figure 7.3. Control Module Self Diagnosis Selection Window
The name of the control module is shown in the window.
Perform: the function that is marked is performed. Offboard Diagnostic Information System Service
switches to the Results tab (except with the Access authorization function).
Cancel: no function is performed and the window closes.
Functions can be performed by double clicking on the name of the function.
You can select from Adaptation, Coding bus master, DTC memory, Basic setting, Identification, Measured values, Output diagnostic test mode and Access authorization.
So long as a function is reported as not supported by the control module on a KWP2000 control module, the
user is shown the message "The selected function is not supported by the control module. Do you want to try
to run the function anyway?"
Yes: The function continues to be performed.
No: Closes the dialog and stops performing the function.
•
Vehicle self diagnosis: clicking this button opens the Self diagnosis functions selection window with self
diagnosis functions for the entire vehicle.
154
OBD mode
Figure 7.4. Vehicle Self Diagnosis Selection Window
Perform: the function that is marked is performed. Offboard Diagnostic Information System Service
switches to the Results tab (except with the Transport mode function).
Cancel: no function is performed and the window closes.
Functions can be performed by double clicking on the name of the function.
Here you can change between Complete DTC memory, Transport mode, List of devices and OBD.
OBD can be accessed in diagnostics during the diagnostic entry. Not all diagnostic functions are available in this
case to prevent any unintended interactions. Identification and Measurements can be selected in the Control
module OBD. The list of components can only be selected in the Vehicle OBD window. All other functions are
grayed-out and cannot be selected until the diagnostic entrance is completed.
155
OBD mode
Figure 7.5. OBD control module window during diagnostic entrance
Figure 7.6. Vehicle OBD window during diagnostic entrance
control module-specific OBD functions can accessed directly from the Results view, in which the function can
be selected from the list on the top right by clicking on
156
.
OBD mode
Note:
See the description in "OBD view"
The function is performed and the results are displayed in the Results tab. Each function for each control module
has its own separate tab there. These tabs have different names for the individual functions.
The names for control module-specific self diagnosis functions are as follows:
Function
Tab Name
Adaptation
ANP
Code Bus master
BMC
Code
COD
DTC memory
DTC
Basic setting
GES
Identification
ID
Measured values
MV
Output diagnostic test mode
SGD
Table 7.1. Control Module Self Diagnosis View Names
With these functions, the address of the control module is also added to the beginning of the name in the tab.
Functions that relate to the entire vehicle may have the following names:
Function
Tab Name
Complete DTC memory
VEH - ESP
Components list
VEH - COMP LIST
OBD
OBD1
Table 7.2. Vehicle Self Diagnosis View Names
The transport mode and access authorization functions are not listed here because they are shown in a separate
window and not in the Results tab.
Example:
The tab for the DTC memory function for the electronic central electrical system with address 09 is named
"09 - ESP".
157
OBD mode
Figure 7.7. Self Diagnosis: Sample Tab Name
Each function can only be active once per control module. If a tab for a function is already open for a control
module and the function is selected again, the tab that is already open will be displayed. To restart the function
completely, you must first click
to close the existing tab.
If the control module does not support the function, a warning appears and the system does not switch to the
Results tab.
Figure 7.8. Warning about adaptation that is not supported
Ok: The note will close.
7.2.3. Logging
The OBD functions can be logged while being performed and saved or printed at any point in time.
At the beginning of OBD, a new OBD log is generated. The user can add the data from the actual result view to
it. It is also possible with some OBD functions, which add data in regular intervals.
158
OBD mode
The screen buttons in the menu are used to use the OBD log. They are described in the OBD log chapter.
Note:
See "OBD log"
7.2.4. Using the keyboard
Some settings can also be made using keyboard shortcuts. The following shortcuts are available:
Keyboard Shortcuts
Function
CTRL + A
Select all entries in a table.
Tab
Selects the controls on a result view one after the other.
CTRL + left arrow
In views with two selection lists: moves an element from
the right to the left list
CTRL + right arrow
In views with two selection lists: moves an element from
the left to the right list
CTRL + up arrow
Moves the selected element up one position in a selection list
CTRL + down arrow
Moves the selected element down one position in a selection list
Shift + left arrow
Switches back to the previous view
Shift + right arrow
Switches to the next view
CTRL + P
Only with output diagnostic test mode and basic setting:
Start actuator test/basic setting (Play)
CTRL + S
Only with output diagnostic test mode and basic setting:
stop actuator test/basic setting (Stop)
CTRL + N
Only during output diagnostic test mode and basic setting and while performing a actuator test/basic setting:
Next actuator/next basic setting (the same as the Next
screen button)
ESC
Only with output diagnostic test mode: in the perform
output diagnostic test mode view: same as the Stop All
screen button.
Table 7.3. Keyboard shortcuts table
Some OBD functions have additional abbreviations. These are described for each function.
7.3. Control Module-Specific Functions
7.3.1. Adaptation
The configuration and operation differ depending on whether the adaptation will be performed with KWP or UDS
control modules.
159
OBD mode
7.3.1.1. Control modules with KWP protocol
At the beginning of the function, the function version must be selected first on some control modules.
Figure 7.9. Selection of function versions
After selecting the function versions and confirming with OK,the Adaptation view is shown.
First, a adaptation channel must be selected there. KWP1281 has channels 0 though 99, KWP2000 has channels
0 through 255. In both cases, channel 0 as a special function: Selecting is resets all control module adaptation
channels.
Figure 7.10. KWP Adaptation
160
OBD mode
To select a channel,
enter channel number in the entry field click Select Channel or with Enter to confirm.
The value is checked for correctness when it is entered. If the number is outside of the permissible value range or
if the field is empty, the field appears in red and the Select Channel screen button is deactivated.
Select Channel: Selects the channel entered.
New adaptation values are entered in the Entry
field.
Actual Value: The adaptation value read from the control module.
Test value: the current test value. Initially identical with the value in the actual value column.
Input: the value entered by the user. Initially identical with the value in the actual value column.
There are four screen buttons on the right side of the view:
Send test value: Send the value from the Entry field for testing to the control module. The value is stored there
only temporarily.
Transfer: programs the changed adaptation value into the control module. This value is stored permanently.
Reset: resets the test value to the original value.
Reset all: if test values were set on more than one channel, they will be reset to their respective initial values as
long as the new values were not programmed into the control module using the Transfer function. This screen
button does the same as channel 0. The user must confirm this action in a dialog:
161
OBD mode
Figure 7.11. Resetting the adaptation
Yes: Resets the test values on all channel to their original value.
No: Closes the dialog without resetting the test values.
As long as it is supported by the control module or its data, measured values
and shown in a list and are updated periodically.
are read from the control module
To change the adaptation value for a channel, complete the following steps:
1.
Channel
.
2.
Click Select channel to confirm.
3.
Change the adaptation value in the entry field and confirm with the send test value or with Enter. The value
is then sent to the control module as the new test value. This process can be repeated as often as desired. A
162
OBD mode
validity test is not performed while entering. If the entered value lies outside of the valid value range, the
Entry field turns red and the Send test value and Accept screen buttons are deactivated.
Example:
Four channels were selected in the illustrations above. For the instrument cluster control module used here
in the example, the language shown is set in this channel. Value 1 stands for German and value 2 stands for
English. If the user now sets the test value to 2, all messages in the instrument cluster display will appear in
English until another test value is entered, the Reset button is pressed or another channel is selected.
As long as the changed value has not been saved in the control module yet, the user can click the Reset button
to reset the test value back to the original value (which is the value in the Actual Value column). The test
value is also reset when a new channel is selected or when changing or closing tabs.
4.
If the correct test value was determined, clicking the Transfer button will save it in the control module. Only
then is the value in the actual value column set to the new value. After saving, the Reset button is deactivated.
It is also possible to apply a newly entered value without Send test value.
7.3.1.2. Control modules with UDS protocol
With UDS control modules, all of the available adaptation functions for the selected control module are listed in
a table when you switch to the Adaptation tab. They can be used to change the control module adaptation values.
This is shown in the following illustration using the control module with diagnostic address 17 (instrument cluster):
Figure 7.12. UDS Adaptation
163
OBD mode
The adaptation functions table has four columns:
Adaptation/Parameter: the name of the adaptation function or parameter.
Current value: the parameter value read out from the control module.
Input: the new parameter value. Click in the Input column for the desired parameter to change the value. The
new value can be selected from a list or entered as free text, depending on the parameter type
.
Unit: the unit of the adaptation value.
Each adaptation function
has parameters
. They are hidden by default. You can double-click in the line
or click the + in front of the function name to display them. Double-clicking again or clicking on - hides the
parameter list again.
To show the parameters for all functions at once, click the
button at the bottom right of the table. Clicking
will then close all of the open parameter lists at once. Opening the lists may take some time, depending on
the number of available functions.
Note:
All values that have not been saved or lost when parameter lists are closed. A message will warn the user about
this:
Figure 7.13. Warning when closing the parameter list
Yes: the values that were entered are discarded and the parameter list is closed.
No: the parameter list stays open and the values entered remain.
There is an entry field under the table which can be used to filter the adaptation functions.
Filter: If texts or partial texts
are entered in the filter field, then only the adaptation functions are displayed,
that contain the name of the text or partial text.
There are three screen buttons at the bottom of the view:
Restore: restores the value for the selected adaptation function that was saved in the control before the last programming procedure. Clicking the button displays the last values used in the Input column. These apply only to
the adaptation values visible. To program the restored values into the control module, click the Transfer button.
Restore all: restores the value for all adaptation functions that was saved in the control before the last programming
procedure. Clicking the button displays the last values used in the Input column. To program the restored values
into the control module, click the Transfer button.
Transfer: once the values for all desired adaptation channels have been changed, they can be saved by pressing
the Transfer button. These apply only to the adaptation values visible. The user must confirm the saving process:
164
OBD mode
Figure 7.14. Security prompt before performing the adaptation
Yes: the new adaptation values will be written.
No: the adaptation values are not written into the control module.
Reset control module: this option is only active for control modules that support it. If there is a check mark, the
control module will be reset after programming the adaptation values.
Before saving, a validity check is performed on the parameter values that were entered as free text. If this check
is not successful, the values will not be written into the control module and the user will be informed about the
cause in an error message:
Figure 7.15. Error message about invalid adaptation value
If the new values were saved successfully, then will then be displayed in the Current value column.
165
OBD mode
Using the keyboard:
Using the arrow keys on the keyboard allow you to navigate between the individual lines in the table. In the edit
mode in the Entry field, you can change using the spacebar or the F2 button. Using the enter key applies the new
value. Using the ESC key leaves the edit mode without applying the value.
7.3.2. Code Bus master
The Code bus master function is only available for control modules that are bus masters. A error message will
appear if it is called up for any other control module.
Figure 7.16. Error message for control modules that are not bus masters
Ok: Closes the dialog without executing the function.
The coding of the components list for a Bust master control module (Gateway) is different from the coding for
other control modules because it is an overall control module coding. A vehicle project may contain several bus
masters.
The Code bus master view contains the components list in a table, meaning all control modules that are assigned
to the selected bus master.
The table consists of three columns. The first column ("Specification") determines if that control module should
be included in the bus master components list. It is irrelevant if the control module to be added is a bus master
control module itself. When opening the Code bus master view, the current code status is read from the control
module. A check mark is entered in this column for all control modules that are already contained in the bus master
control module components list.
The second column contains the current status of the control module in the components list ("Actual"). The
systems have the following meanings:
The control module is installed and coded.
The control module is installed but not coded.
The control module is coded but not installed.
The third column contains the diagnostic address, followed by the control module name separated by a hyphen. If
no diagnostic address is specified for a control module, the node address will be displayed in brackets instead. The
node address 0x00 is not displayed. If the control module name is unknown, "Unknown system" will be displayed
instead.
Example: 00 - Unknown system or [49] - Unknown system
The table can be sorted in ascending and descending order by clicking on the column title.
166
OBD mode
The buttons below the table differ depending on whether the bus master is a KWP or UDS control module. The
different views are described in the information that follows.x
7.3.2.1. Coding KWP bus masters
Figure 7.17. Coding KWP bus masters
Once the user has configured the components list, the coding process can be started using the Transfer button.
First, a note appears that the use must confirm.
Figure 7.18. Prompt before coding
Yes: Writes the code in the bus master control module.
No: Closes the dialog without writing the code.
During the coding, a dialog with a message indicating that the coding process is running appears.
167
OBD mode
Figure 7.19. Progress bar during coding
If there are errors during the coding process, the process stops and an error message is shown.
Figure 7.20. Error when coding (example)
If the coding process was completely successfully, the components list will be read from the Gateway control
module again and displayed.
Once the code that was read out is changed, the Restore button is activated. Clicking on this button restores the
code that was read from the bus master control module during the last coding procedure.
The Special coding button can be used to edit the special code determined based on the control module. This
contains the vehicle brand, vehicle version, the number of door and if the vehicle has right-hand or left-hand drive.
This information is already in the bus master control module and can be changed by the user.
If a special code is present, it will be displayed in the text line above the button. If no special code was read,
the text "Special code not available" will appear there. If the control module does not support special coding, the
button will be deactivated.
Figure 7.21. Edit special code
When this button is pressed, a dialog window opens where the special code can be changed using selection lists.
The special code that is read is already entered.
The
button becomes active once the code information is changed. It resets the information back to the original
values.
Write: Writes the selected code in the control module and updates the "special code" text in the components list.
The control module list coding is not changed.
168
OBD mode
Cancel: Closes the dialog without writing the code.
Bus master control modules that are addressed with service 22 do not have a special code so neither the button
nor the note text are displayed.
7.3.2.2. Coding USD bus masters
Coding UDS bus master control modules is identical to KWP bus masters, except there is no special code. Neither
the button nor the note text are displayed. There is the "Automatic coding" funciton instead, which is described
in the information that follows.
There is also a GW Info column that shows on which CAN bus a control module is located or if it is a bus master.
Figure 7.22. Coding USD bus masters
Automatic coding: This button writes the code based on the installation status of the subsystems that is detected
by the control module. This means the code will be written for all control modules that are marked with the
and
symbol under "Current installation". After pressing this button, the use must confirm the procedure:
Figure 7.23. Prompt before automatic coding
169
OBD mode
Yes: The code is written.
No: Closes the dialog without writing the code.
During the coding, a dialog with a message indicating that the coding process is running appears.
Figure 7.24. Progress bar during coding
If there are errors during the coding process, the process stops and an error message is shown.
Figure 7.25. Error when coding (example)
If the coding process was completely successfully, the components list will be read from the Gateway control
module again and displayed.
170
OBD mode
7.3.3. Code
The configuration and operation differ depending on whether the coding will be performed with KWP or UDS
control modules.
The process of selecting the subsystem to be coded,meaning the control module that is subordinate to the current
control module, is the same in both cases:
1.
The system will check if subsystems are present.
2.
The system names of all available subsystems are displayed in a selection list. An entry is generally not
preassigned. Instead, "Please select a subsystem" is displayed in the list.
3.
The user selects a subsystem or the control module itself.
4.
The current control module code is read automatically.
If the control module does not have any subsystems, steps 2 and 3 are skipped. The control module is then selected
automatically when the Coding tab opens and the code is read directly.
The remaining steps differ depending on the diagnostic protocol and code type.
Note:
Gateway control modules are the exception. The Coding function cannot be selected for these control modules.
171
OBD mode
7.3.3.1. Coding KWP control modules
The following information explains the Coding function for KWP control modules. There are tow possible code
types for these control modules: short coding and long coding. The code type depends on the control module
and cannot be influenced by the user.
1.
Short Coding
Figure 7.26. Short Coding
Transfer: programs the code into the control module.
Restore: enters the last coded value into the New code field. Clicking Transfer saves the restored code in
the control module.
First the application checks if the control module, on which the coding should be performed, has any subsystems. If this is the case, all subsystem is displayed in the system ID list. There you can select either a
subsystem or the control module.
After opening the tab or selecting the desired subsystem, the code is read from the control module and displayed in the Old code field. The new value can be entered in the New code field and confirmed with the
Enter key. The Transfer button will then become active.
After confirming the Transfer button, a message with a security prompt appears.
172
OBD mode
Figure 7.27. Security prompt before coding
Yes: programs the new code value into the control module.
No: the programming process is not performed.
If the coding was successful, another message appears:
Figure 7.28. Confirmation message after coding
After confirming the message, the user is prompted to reset the control module:
Figure 7.29. Prompt to reset the ignition
To do this, the ignition key must be in the "Off" position and then turned back to the previous position.
The new value will now be displayed in the Old code field followed by the original code value in parentheses:
Figure 7.30. New and old code
This process can be repeated as often as desired. If the coding was not successful due to an invalid value or
another problem, the user will be informed with an error message and the previous code will not be changed.
The message depends on the error that occurred. For example, it could indicate that vehicle communication
could not be established. The coding process can be performed again after correcting the problem. The following illustration shows an example of an error message:
173
OBD mode
Figure 7.31. Error message when coding due to incorrect data
2.
Long Coding
With long coding, the values to be coded are displayed as a bit field up to 40 bytes long. It is displayed
both in binary and hexadecimal format. The code is displayed in the same way as binary coding for UDS
control modules.
Note:
Refer to "UDS Binary Coding".
7.3.3.2. Coding UDS control modules
UDS control modules have binary coding and plain text coding. These are different ways of displaying the same
type of code. As long as the data supports it, plain text coding is displayed by default after accessing the Coding
function and, if necessary, after selecting the subsystem. Otherwise, binary coding is displayed.
174
OBD mode
1.
UDS binary coding and KWP long coding
The binary coding display for UDS control modules and the long code for KWP control modules are identical.
The following description is based on binary coding but it still applies to long coding.
The code string is displayed in a table format. Each row in the table corresponds to a byte in the code string:
Figure 7.32. Binary coding
The table has five columns:
Byte No.: the byte number in the code string.
Current Hex Value: the value in hexadecimal format.
Current Binary Value: the value in binary format.
Hex Input: the user input in hexadecimal format.
Binary Input: the user input in binary format.
There are three buttons below the table:
Transfer: programs the changed code string into the control module.
Restore: restores the last code that was used.
Plain text coding: switches to plain text coding if it is supported by the control module. If not, the button
will be deactivated.
The value can be changed in both binary and hexadecimal. When you click in one or both cells, or use the
spacebar or the F2 button, a new input screen appears:
175
OBD mode
Figure 7.33. User input with binary coding
If one of the two values was changed, the corresponding binary or hexadecimal value will update automatically during input. Closing the the input form discards the changes.
Transfer: the changes are transferred into the table.
Cancel: discards the changes.
Once all of the desired changes have been made, the check sum corresponding to the code string must be
entered into the Check sum input field. The check sum can be calculated as follows:
The code string is divided into groups containing 2 bytes each. If there is an uneven number of bytes, the
value 00 will be added to one of the bytes. The values are added and any possible excess is rounded down.
Example:
Code string: F0 01 02 04 08 10 20
F001 +
0204 +
0810 +
2000
11A15 & 0xFFFF = 1A15
Check sum: 1A15
The user must press the Transfer button to program the code into the control module. A prompt appears
before saving the code:
Figure 7.34. Security prompt before binary coding
Yes: the code string is checked for errors based on the check sum.
No: the coding process is cancelled.
If there is a check mark next to "Reset control module", the control module will be reset automatically when
coding is complete. This means the control module will be switched off and then on again automatically.
176
OBD mode
Otherwise, the user must reset the control module manually when coding is complete. To do this, turn the
ignition key once to the "Off" position and then back to the previous position.
If nothing was entered in the Check sum field, a warning message appears:
Figure 7.35. Note about missing check sum for binary code
Yes: programs the code string into the control module.
No: the code string is not programmed.
If a check sum was entered that does not match the code string, the following message appears:
Figure 7.36. Note about incorrect check sum for binary code
Yes: programs the code string into the control module anyway.
No: the code string is not programmed.
If the coding was successful, another message appears:
Figure 7.37. Confirmation message after coding
The new parameters are now displayed in the table.
If there is an error, the user will be notified with an error message indicating the the code could not be saved.
The message depends on the error that occurred. For example, it could indicate that vehicle communication
could not be established.
177
OBD mode
The coding process can be performed again after correcting the problem.
Note:
Refer to "Error Messages".
If the code is successful and the control module was not reset automatically, the user will be prompted to
reset the control module manually after confirming the message:
Figure 7.38. Prompt to reset the ignition
To do this, the ignition key must be in the "Off" position and then turned back to the previous position.
In UDS control modules that support the function, the user can click the plain text button to switch to the
view for plain text coding. Changes that were already made in the binary view are not transferred here. In
this case, the user will be informed with a message:
Figure 7.39. Warning when changing to plain text coding
Yes: changes to plain text coding. Any changes made in binary view will be discarded.
No: Does not change to plain text coding. Changes made in the binary view will remain.
Once the code is saved with no errors, the Restore button is activated. Clicking this button will restore the
last code that was used. To program the restored code into the control module, click the Transfer button.
2.
Plain text coding
When changing to plain text coding., the current code string is read from the control module and separated
into its individual parameters. These are displayed with the name and read value in the table.
178
OBD mode
Figure 7.40. UDS Plain Text Coding
The table has three columns:
Parameter name: the name of the parameter in the code string.
Current value: the current code value.
Input: the user input.
It is also possible to filter the parameters.
Filter: If a text or a partial text is entered in the filter field, then only those parameters will be displayed, that
contain the name of this text or partial text.
There are three buttons below the table:
Transfer: programs the changed code string into the control module.
Restore: restores the last code that was used.
Binary coding: changes to the binary coding view.
To change the value of a parameter, the user must click the input column in the desired parameter line. The
value can then be selected from a selection list.
With this code type, it is not necessary to enter a check sum because only codes that come from the data and
are therefore valid can be selected.
Click the Transfer button to start the coding process. Except for checking with the check sum, the process
runs the same way as with binary coding. Refer to that section for more information.
179
OBD mode
Note:
Refer to "UDS Binary Coding".
7.3.4. DTC memory
The DTC memory function reads the current DTC memory content for a control module. It also offers the option
of erasing the DTC memory.
Figure 7.41. KWP DTC memory
The content of the DTC memory is displayed in tables arranged one over the other. The upper table
the results read from the selected control module. It has four columns:
lists all of
Fault Code: the code number of the fault.
SAE Code: the code number of the fault in SAE format.
Fault Text: the description of the fault.
Active: indicates if the fault is active or not.
By clicking on the fault line,
the
ambient conditions (AC) are displayed in the lower table. Additional
information, such as mileage, date, fault status etc. as well as the number and type can vary from control module
to control module. The table contains two columns:
180
OBD mode
Type/Name: the type of information.
Value: the value that was read.
There may be a + in front of the name. This indicates that there is detailed information that can be displayed by
clicking the +. If the group is opened, there will be a - in front of the main entry. Clicking on this symbol hides
the group again.
To the right near the table there are three areas for additional functions:
Update
: pressing the Now button reads the DTC memory again. Activating the In cycle checkbox causes the
DTC memory to be read in cycles. The input field below specifies the cycle time. If the cycle time is changed, the
Now button must be clicked again to accept the new cycle time.
Sort
: criteria can be entered here for sorting the DTC memory entries in the upper table. Clicking the column
titles in the upper table
reverses the sorting sequence (ascending/descending). The default sorting is ascending
based on priority and the time when the fault occurred:
Figure 7.42. Sorting the DTC memory entries
Erase : Clicking on DTC memory or using the Delete button erases the contents of the DTC memory in the
selected control module. A confirmation dialog follows. Confirming with the Yes button erases the DTC memory.
Entering No cancels the procedure.
On some control modules, it is possible to erase not only the DTC memory of the control modules itself, but the
DTC memories of all OBD control modules connected. In this case the OBD systems screen button is activated.
A warning message appears when it is confirmed. If this is confirmed with Continue, then the DTC memory in
all OBD control modules are erased. Cancel closes the dialog without any additional action.
Notice:
After erasing the DTC memory, it is read again immediately and the content is displayed. If the DTC memory is
not empty and it contains all or some of the faults that were displayed before deleting, the control module did not
accept the erase command or that fault was entered again immediately because the cause was not corrected.
Erased DTCs CANNOT be recovered.
181
OBD mode
Figure 7.43. UDS DTC Memory
With UDS control modules, another table is displayed to the right of the ambient conditions table
mation about the fault status.
Name: name of the status bit.
Value: value of the status bit.
182
with infor-
OBD mode
7.3.5. Basic setting
The basic setting configuration and the displayed measured values differ depending on whether the function was
carried out on control modules with KWP or UDS protocol.
7.3.5.1. KWP control module basic setting
The following information explains the steps for completing the Basic setting function on a KWP control module.
At the beginning of the function, the function version must be selected first on some control modules.
Figure 7.44. Selection of function versions
After selecting the function versions and confirming with OK, the basic setting view is displayed.
183
OBD mode
Figure 7.45. KWP Basic Setting
The
desired setting channel must be entered in the entry field by clicking on the Select channel screen button
or using the enter key.
KWP1281 has channels 0 though 255, KWP2000 has channels 1 through 254. A validity test is not performed
while entering. If the value entered is outside of the valid value range, the entry field turns red and the Select
channel screen button is deactivated.
In the first list,
all measurements are listed that are available for the selected channel if the control module
is not in basic setting.
Value: the value reported by the control module.
Click Activate to start the setting process. All measurements are processed one after the other and shown in the
lower list
.
The setting process stops if a different channel is selected or the view is closed while the function is running. The
same applies if the screen button next to the list is activated.
.
Some basic setting procedures require action from the user. If this is case, then the required action
is displayed in
the list of currently active measurements. The setting process continues automatically once the action is performed.
The result appears in the Status field when the basic setting is completed.
184
OBD mode
Example:
The required action "Press accelerator pedal" is displayed as the measured value. If the user completes this action,
this text will disappear from the measured value table and the setting process will continue.
After the basic setting is completed, the new measurements are displayed in the list . If the basic setting was
not successful, a dialog appears with an error message that the user must confirm. The message depends on the
error that occurred. For example, it could indicate that vehicle communication could not be established. The basic
setting process can be performed again after correcting the problem.
Note:
Refer to "Error Messages".
7.3.5.2. UDS control module basic setting
With UDS control modules, additional parameters can be set and measured values can be selected after selecting
the basic settings. The following steps are required:
1.
Basic settings selection
2.
Setting basic setting parameters
3.
Selecting measured values
4.
Performing the basic setting
The following information describes the individual steps in detail.
185
OBD mode
Basic settings selection
Figure 7.46. UDS Basic Setting - Basic Setting Selection
In the first view of the function, the desired basic settings must be selected. The available basic settings are
displayed in the list on the left
beginning.
. The list on the right
contains the selected settings. It is empty in the
Filter: If a text or a partial text is entered in the filter field, then only those basic settings will be displayed, that
contain the name of this text or partial text.
Moves the selected basic settings from left list to the right list.
Moves all basic settings to the right list.
Moves the selected basic settings from right list to the left list.
Moves all basic settings to the left list.
The list of selected basic settings
right list.
can be sorted. To do this, a specific basic setting must be selected in the
Moves the entry up one position.
Moves the entry down one position.
Switches to the next view, Setting parameters.
If a parameterization or measurement selection is not necessary, you can change directly to perform basic
setting with this screen button.
186
OBD mode
Setting Parameters
Figure 7.47. UDS Basic Setting - Setting Parameters
Default Parameters: press this button to set all parameters back to their standard values. The system then checks
for missing or invalid values and marks the affected parameters and basic settings.
The left list
by default.
contains the basic settings that were selected in the previous view. The first basic setting is marked
Once a basic setting is selected, the
associated parameter is displayed in the right table. Depending on the
parameter type, its value can either be selected from a list field in the right column or entered as free text. If entered
as free text, the system then checks if the valued entered is valid. If problems are found or a value is missing, the
affected parameter is marked in red and the associated basic setting is displayed in bold red font.
Note:
Refer to the illustration of parameter problems in "Output Diagnostic Test Mode".
Switches to the next view, Measured Value Selection. As long as there are problems with the parameters that
were set, meaning at least one parameter is marked in red, an error message will appear when clicking the button.
You can only switch to the next view once all parameters have valid values and there are no more red markings.
Switches back to the previous view. Even if basic settings were added or removed there, all of the affected
settings remain the same for the remaining basic settings.
Note:
Refer to "Error Messages".
187
OBD mode
Measured Value Selection
Figure 7.48. UDS Basic Setting - Measured Value Selection
In this view, measured values that will be displayed during the process can be selected for each basic setting.
The available measurements
are displayed on the left side. The measured values to be displayed can be selected
here the same way basic settings are selected. The list on the right
is empty in the beginning.
contains the selected measured values. It
Moves the selected measured values from the left list to the right list.
Moves all measured values to the right list.
Moves the selected measured values from the right list to the left list.
Moves all measured values to the left list.
Filter: If a text or a partial text is entered in the filter field, then only those measurements will be displayed, that
contain the name of this text or partial text.
The list of selected measured values
in the right list.
can be sorted. To do this, a specific measured value must be selected
Moves the entry up one position.
Moves the entry down one position.
Changes to Performing Basic Settings.
188
OBD mode
Switches back to the previous view. Even if the parameters are changed or basic settings are added or removed
there, the measured value selection remains for the other basic settings.
Performing Basic Settings
Figure 7.49. UDS Basic Setting - Performing
Name: Name of the basic setting, measured value or measured value group.
Value: the measured value.
The basic setting for the control module is performed in this view. The basic settings and the associated measure
values
are displayed open.
In the bottom list,
all the measurements applicable for all basic settings are displayed.
Measured values can be arranged in groups. When this happens, a + is added to the beginning to indicate there is a
group and the right column will be empty. Clicking + opens the group and displays the measured values. Clicking
on the - that is now in front of the group will hide the group again.
The status of the currently selected basic setting is displayed above both tree structures in the UDS Basic Setting
- Status field. Possible status displays are: active, not active and ended.
To begin the process, first select the basic settings to be performed. You can click to select one or more basic
settings.
Start: Starts performing the basic setting.
Stop: Stops the basic setting.
Stop all: Stops all active basic settings.
Next: Switches to the next basic setting.
189
OBD mode
switches back to setting the parameters. This stops the basic setting. This also applies when the tab is closed
or exited. It does not start again automatically when the user returns to the Performing Basic Setting view. It
must be started again manually.
switches back to the basic setting selection. This stops the basic setting.
If you clicked Next to go to the next basic setting, then clicking on Start starts the basic setting selected. If it
is ended, the system will continue with the next basic setting in the list. If the end of the list is reached, it will
move to the first entry in the list. The measured values for the basic setting that is currently running are shown
and all others are hidden.
The Start screen button is deactivated and is grayed out. Clicking on Stop stops the basic setting. Click Next to
continue. The system will begin with the basic setting that is currently selected, regardless of where the procedure
was stopped.
Some basic setting procedures require action from the user. If this is the case, the required action is shown in the
measured value table for the current active measured value. The setting process continues automatically once the
action is performed.
Note:
Some settings can also be made using keyboard shortcuts. See "Using the Keyboard"
Note:
Refer to Example for KWP Control Modules.
The new measured values that were set are displayed once the basic setting is complete. If the basic setting was
not successful, a dialog appears with an error message that the user must confirm. The message depends on the
error that occurred. For example, it could indicate that vehicle communication could not be established. The basic
setting process can be performed again after correcting the problem.
Note:
Refer to "Error Messages".
190
OBD mode
7.3.6. Identification
The self diagnosis function Identification is used to read various fixed values from the control module such as
part number, software version, etc. These values can only be displayed. They cannot be changed.
Figure 7.50. Results window for OBD identification
In the example here, the central electrical system control module was selected and the identification was performed.
The upper table
has three columns that contain information read from the control module.
System identification: the name of the control module.
Part number: the control module's unique part number.
Software version: the current software version.
191
OBD mode
The main control module that is being addressed is displayed in the top line of the tab. The other lines - if applicable
- contain additional supporting control modules that are reached through the main control module. The example
above shows the wiper module.
The entry must be marked in the upper table for additional identification characteristics.
For the information displayed in the lower table, the can
switch between standard identification characteristics
and the expanded identification characteristics for the systems selected above. Use the Display expanded identification screen button. If this was confirmed, then the expanded identification is displayed and the screen button
changes to Display default identification. The standard identification is displayed automatically after selecting
an entry in the upper table.
This screen button is deactivated for KWP1281 control modules.
The Filter entry field is active when the expanded identification is displayed. The attributes can be filtered here.
are entered in the filter field, then only the attributes are displayed, that contain the name of the text or partial text.
For UDS control modules, two screen buttons are displayed on the right side at the bottom, with with all the
attributes of the expanded identification can be opened or closed.
open all attributes for the expanded identification.
closes all attributes for the expanded identification.
Using the Update screen button reads the identification data again.
192
OBD mode
7.3.7. Measured values
The top left indicates the control module that was selected. This example shows the engine electronics. The Measured values tab has two views: one for configuring the measured values to be recorded (see the upper illustration)
and one to display the measurement results. After compiling the measured values to be displayed in the first view
as shown in the upper illustration, click the Show measured values button to enter the measured value display.
The configuration of the measurements to be displayed differs only slightly between control modules with KWP
and control modules with UDS protocol.
First, the measured values to be read must be selected:
Figure 7.51. Measured Value Selection
For control modules with KWP protocol, measurement blocks with up to four measured values are read. The
measured value block number (1 through 254) and, if necessary, the measured value position within the affected
block (separated by a period) are entered in the Block.Position input field. The Accept button is active after
completing the entry. If a block number is entered that is outside of the range of valid values, Transfer remains
deactivated.
Clicking the Transfer transfers the input in the right list
, which contains the selected measured values. If
only the block number is entered, all four measured values for this block will be displayed when you click the
Transfer button. By entering additional measured values, any four measured values from various blocks can be
configured for display.
193
OBD mode
Example:
Input: 8
Apply
Accepted selection: 8.1, 8.2, 8.3, 8.4
• all measured value blocks are transferred.
Input: 1.2
Apply
Accepted selection: 1.2
• only the measured value in the selected position is transferred.
The buttons for moving blocks become active when you click on the desired measured value block in either list.
Moves the selected measured value blocks to the left list
Moves the selected measured value blocks to the right list
.
.
Moves all measured values blocks to the left list.
Moves all measured value blocks to the right list.
The list of selected measured value blocks
can be sorted:
Moves the selected entry up one position.
Moves the selected entry down one position.
These buttons are used the same way with UDS control modules once the measured value name is selected as
described above.
After all measurements were selected, clicking on the
to Display measurements.
screen button or using the enter key changes the view
194
OBD mode
Figure 7.52. KWP - Measured value display
Name: the name of the measured value.
Value: the measured value.
UDS control modules group the measurements. Clicking on the + opens and clicking on - closes. By default,
all groups are open.
The measured values update can be controlled using the controls in the Update area. The default setting is updating
the measured values in cycles as quickly as possible. When a measurement is selected, using the enter key performs
the same action.
You can set the desired update interval in the input field. You can switch the update cycle off by removing the
check mark in the "cycle" checkbox. When is is not selected, you can update the measured values as desired using
the Now button.
Using the
screen button or using the ESC key takes you back to the first view and can change the selection
of the measurements to be displayed.
195
OBD mode
7.3.8. Output diagnostic test mode
The output diagnostic test mode configuration and the displayed measured values differ depending on whether the
function was carried out on control modules with KWP or UDS protocol.
7.3.8.1. KWP control module output diagnostic test mode
At the beginning of the function, the function version must be selected first on some control modules.
Figure 7.53. Selection of function versions
After selecting the function versions and confirming with OK,the output diagnostic test mode view is shown.
196
OBD mode
Figure 7.54. KWP Output Diagnostic Test Mode
Value: the measured value.
You can select between selective and sequential output diagnostic test mode for control modules with the
KWP protocol. The default selection is sequential. Not all diagnosis types are supported, depending on the control
module. The buttons are deactivated if this is the case.
Start: Starts the output diagnostic test mode.
Next Switches to the next actuator (not supported by all control modules).
Stop Stops output diagnostic test mode.
When the user selects selective output diagnostic test mode, then a numeric actuator code is to be entered in
the field next to it. If the actuator code is missing or is invalid, the field stays red. The value range is 0 - 65535
(decimal) or 0x0000 - 0xFFFF (hexadecimal).
First, if one of the two options was selected - and the control module support s this - the Start screen button is
activated. Clicking this button starts output diagnostic test mode.
1.
Selective output diagnostic test mode
Output diagnostic test mode starts and the actuator code input field is locked until the function ends or is
cancelled.
2.
sequential output diagnostic test mode
After starting diagnosis on the first actuator, the buttons Start and the actuator code input field are deactivated
until the function ends or the user cancels it using the Stop button.
197
OBD mode
Some control modules allow diagnosis to continue on the following actuator while the function is running. If
this is the case, the Next button is activated while the function is running. Clicking this button stops diagnosis
on the current actuator and starts with the next one.
In control modules that use the KWP 2000 protocol, the measured values are read from the control module in
cycles in addition to the diagnostic status. A selection is not possible. The control module specifies which measured
values are displayed.
If output diagnostic test mode ends, the results are displayed in the Output diagnostic test mode - status field.
Figure 7.55. Output Diagnostic Test Mode Status
If addition measured values were read from the control module, they are displayed in the Measured values table.
Note:
Some settings can also be made using keyboard shortcuts. See "Using the Keyboard".
198
OBD mode
7.3.8.2. UDS control module output diagnostic test mode
Output diagnostic test mode can be figured more extensively in control modules with the UDS protocol. After
selecting the output diagnostic test mode function for a UDS control module, the user then enters the Actuator
selection view (refer to the illustration UDS actuator selection). This contains a list of available control module
actuators whose individual parameters can be set. The selected and configured actuator tests can then be run in
sequence or in parallel.
You can end the function at any time by closing the tab. If you leave the tab (for example by selecting another tab)
or change the view, the status of the function in terms of the parameters set is maintained but any output diagnostic
tests that are currently running will stop. This also applies when switching from running output diagnostic test
mode back to setting parameters. It is not possible to add or set parameters for individual actuators when output
diagnostic test mode is running.
The following information describes the four phases of output diagnostic test mode for UDS control modules in
detail.
1.
Actuator selection
Figure 7.56. UDS actuator selection
The left list
This view contains all available actuators for the selected control module. The list can be
sorted alphabetically by clicking on the column header. The list on the right
tested. It is empty in the beginning.
contains the actuators to be
One or more actuators can be selected by clicking or using the keyboard. The first actuator that begins with
the letter entered is selected. If the same letter is entered again, the next element that starts with this letter
is selected.
The actuators can be filtered in the Filter entry field. are entered in the filter field, then only the actuators
are displayed, that contain the name of the text or partial text.
199
OBD mode
Note:
For additional information on using the keyboard, refer to the table "Keyboard Shortcuts".
When you click an actuator in either of the lists, the buttons to move that actuator become active.
Moves the selected actuator to the left list
Moves the selected actuator to the right list
.
.
Moves all actuators to the left list.
Moves all actuators to the right list.
The list of selected actuators
can be sorted:
Moves the selected entry up one position.
Moves the selected entry down one position.
Switches to the next view, Setting parameters.
If a parameterization is not needed, click on this screen button to change to Performing Output Diagnostic Test Mode.
2.
Setting Parameters
Figure 7.57. Setting UDS Actuator Parameters
200
OBD mode
The left list
by default.
contains the actuators that were selected in the previous view. The first actuator is marked
The available parameters for each selected actuator are displayed in the right table
. Depending on the
parameter type, its value can either be selected from a list field in the right column or entered as free text. If
entered as free text, the system then checks if the valued entered is valid. If problems are found or a value is
missing, the affected parameters are marked in red and the associated actuator is displayed in bold red font.
Figure 7.58. UDS output diagnostic test mode - problems with wetting parameters
Press the Default Parameters button to set all parameters back to their standard values. The system then
checks for missing or invalid values and marks the affected parameters and actuators.
Switches to the next view, Measured Value Selection. As long as there are problems with the parameters
that were set, meaning at least one parameter is marked in red, an error message that warns the user that there
is still a problem with the data will appear when clicking the button. You can only switch to the next view
once all parameters have valid values and there are no more red markings.
Switches back to the previous view. Even if actuators were added or removed there, all of the affected
settings remain the same for the remaining actuators.
Note:
Refer to "Error Messages"
.
3.
Measured Value Selection
201
OBD mode
Figure 7.59. UDS Measured Value Selection
In this view, measured values that will be displayed during the process can be selected for each actuator.
The measurements
. The measured values to be displayed can be selected here the same way actuators
are selected. The list on the right
contains the selected measured values. It is empty in the beginning.
The measurements can be filtered in the Filter entry field. are entered in the filter field, then only the measurements are displayed, that contain the name of the text or partial text.
When you click on a measured value in either of the lists, the buttons to move that actuator become active.
Moves the selected measured values to the left list
Moves the selected measured values to the right list
Moves all measured values to the left list.
Moves all measured values to the right list.
The list of selected measured values
can be sorted:
Moves the selected entry up one position.
Moves the selected entry down one position.
202
.
.
OBD mode
Note:
The measured values can also be selected with the keyboard. For additional information on using the keyboard, refer to the table Keyboard Shortcuts.
Changes to Performing Output Diagnostic Test Mode.
Switches back to the previous view. Even if the parameters are changed or actuators are added or removed
there, the measured value selection remains for the other actuators.
4.
Performing Output Diagnostic Test Mode
Figure 7.60. UDS Output Diagnostic Test Mode
The actual output diagnostic test mode is performed in this view. The selected actuators and
the associated measured values are displayed in the upper section using a tree structure. In the default view, the
measured values are hidden. Click + to show the measured values. The actuator parameters and their values
are shown when the mouse cursor is placed over the actuator.
In the bottom tree structure,
all of the overall actuator measured values are displayed.
Measured values can be arranged in groups. When this happens, a + is added to the beginning to indicate
there is a group and the right column will be empty. Clicking + opens the group and displays the measured
values. Clicking on the - that is now in front of the group will hide the group again.
The status of the output diagnostic test that is currently selected is displayed in the Output diagnostic test
mode - status field. Possible status messages are: active, not active and ended.
To begin output diagnostic test mode, first select the actuators to be checked. You can click to select one
or more actuators.
203
OBD mode
Start: Starts the actuator test.
Stop: Stops the actuator test.
Stop all: Stops all active actuator tests.
Next Switches to the next actuator.
Switches to the previous view. All actuator tests stop. This also applies when the tab is closed. The actuator
test does not start again automatically when the user returns to the Performing output diagnostic test mode
view. It must be started again manually.
changes back to actuator selection. The actuator test is likes interrupted.
Note:
Figure 7.61. Example of an actuator test on several actuators
The Start and Stop screen buttons are meant only for the currently selected actuator test.
For example, if the user selects the actuators
through
is clicked. If the user then reduces the selection to actuators
and
will stop and actuator
independently of each other.
before starting, these tests will start when Start
and
and presses Stop, only actuators
will continue running. Actuators can be started and stopped at any time
Using the Next button, a sequential actuator test sequential actuator test can be performed on a UDS control
module. There must not be any other active actuator tests. An actuator must also be selected from the list on
the left. If both conditions are met, the button will be activated.
Clicking on Next switches to the next actuator and clicking on Start starts the test for the actuators. If the
end of the list is reached, clicking Next will move to the first entry in the list. The measured values for the
actuator test that is currently running are shown.
Clicking Stop stops the actuator test that is currently running. The sequential actuator test can be continued
using Next or Start. The system will begin with the actuator that is currently selected, regardless of where
the test was stopped.
Note:
Some settings can also be made using keyboard shortcuts. See "Using the Keyboard".
204
OBD mode
7.3.9. Access authorization
To perform access authorization, a dialog opens. The content of the dialog differs with each protocol.
It appears automatically when access authorization is required in a different OBD function.
205
OBD mode
Figure 7.62. Access authorization
206
OBD mode
Login methods: the type of access authorization to be performed is selected here.
Control modules with KWP1281 protocol have only automatic access authorization.
Control modules with KWP 2000 protocol have the following possibilities to perform the access authorization.
•
Automatic access authorization
•
Access authorization level 3/4
•
Access authorization level 5/6
Control modules with UDS protocol have different methods for access authorization depending on the data.
Login code: Enter the access code in this field. By default, the password is masked over with *. As long as the
field is empty, it remains red and the Perform screen button is deactivated.
Display login code: Selecting this option displays the password in the login code in plain text.
Perform: Performs the access authorization with the selected login method.
Cancel: Cancels the dialog without issuing a access authorization.
In the Information area at the top of the dialog, the control module, for which the access authorization is being
performed, is displayed. If the dialog was opened from a different OBD function, then the NRC, from which was
sent from the control module, is displayed.
In order to perform access authorization, select the login method and enter the password in the login code field.
Clicking on Perform begins issuing the access authorization.
If the access authorization was performed successfully, a message appears that closes automatically after a few
seconds.
207
OBD mode
Figure 7.63. Access authorization - successful
In the case of an error or if the access authorization was interrupted, a message appears.
208
OBD mode
Figure 7.64. Access authorization - unsuccessful
209
OBD mode
7.4. Vehicle-specific functions
The following describes the OBD functions, which do not apply to specific control modules, but rather to the
entire vehicle.
7.4.1. Complete system DTC memory
The Complete system DTC memory function reads the DTC memory for all control modules installed in the
vehicle.
Figure 7.65. Complete system DTC memory
The view consists of a table with two columns:
System: The control module diagnostic address followed by its name.
Fault: the number of faults that were read.
When changing the view, the table updates automatically, meaning it attempts to read the faults for every control
module that is installed.
If the control module DTC memory is empty, a 0 is displayed in green font in the same column. For control
modules that have entries in the DTC memory, the number of faults is displayed in red font in the Fault column.
A + also appears in front of the diagnostic address. If the user clicks on it, the faults that are occurred are listed in
detail. For additional information on a fault, click the + in front of the fault.
210
OBD mode
If the DTC memory for a control module could not be read, the Fault column remains empty for this control
module.
The user has three possibilities to update the table: Clicking on now, using CNTRL + P, or checking periodic.
In the first and second case, the table is updated one time. Clicking Cancel stops the update.
If the user decides to update in cycles, the table updates continuously according to the interval shown in the text
field below the option. The value is entered in seconds. An interval of 30 seconds is used by default. If no value
is entered, the last value entered is used. If the interval is smaller than the time needed for the update, the reading
will begin again immediately after a the current reading cycle ends. The interval can be changed during the update
cycle. Use the Return key to confirm the new value. To end the update cycle, clear the check mark next to the
Cycle option. You can also update the table between cycles by clicking the now button.
After all DTC memories are read, the Read DTC memory function can be selected for the affected control module
by double-clicking on a line in the table. For this to work, it must be possible to read the control module DTC
memory. The DTC memory content for the selected control module is displayed in a new tab.
Note:
Refer to "DTC memory".
Once the DTC memory is read completely at least one time, the user has the option to erase the DTC memory for
the entire system. There are several ways of doing this that depend on the control module or vehicle. For example,
the DTC memories can be erased all at once or one after the other.
Figure 7.66. Selecting the method of erasing the DTC memory
To erase the DTC memory at once, select Complete system in the list in this example (preselected as the default)
and click the Perform button. A security prompt appears:
Figure 7.67. Warning message before erasing the DTC memory
Yes: the DTC memories for all control modules that support this function are erased.
No: the deleting process is not performed.
Once the deleting process has ended, a dialog lists any errors that may have occurred. If the process was successful,
there are no additional messages.
To erase the control module DTC memories one after another, select Individually from the list. The security
prompt mentioned above appears and the user must confirm it with Yes. The control module DTC memories are
then erased one after the other. The control module DTC memory is read again after each deletion process and
the results are displayed in the table.
211
OBD mode
Notice:
After erasing the DTC memory, it is read again immediately and the content is displayed. If the DTC memory is
not empty and it contains all or some of the faults that were displayed before deleting, the control module did not
accept the erase command or that fault was entered again immediately because the cause was not corrected.
Erased DTCs CANNOT be recovered.
7.4.2. Transport mode
The following dialog opens:
Figure 7.68. Transport mode
Perform: performs the selected function.
Finish: closes the dialog.
Cancel: cancels the switch to transport mode.
To switch transport mode on or off individually, select the corresponding item in the list and click "Perform" to
confirm. The result of the function (successful / not successful) is displayed in the information area above the list:
Figure 7.69. Message indicating the switch to transport mode was successful
If an error occurs, a new message with detailed information about the error will appear:
Note:
Refer to "Error Messages".
212
OBD mode
Figure 7.70. Transport mode
Depending on the type of error that occurred, an additional error message with detailed information may also
appear (for example, that a connection to the vehicle could not be established). After correcting the problem, you
can try switching to or from transport mode again.
7.4.3. Components list
The Components list shows the vehicle's coded actual installation. The number of faults that have occurred is
also displayed for each control module, if applicable.
Figure 7.71. Components list
213
OBD mode
System: The control module diagnostic address followed by its name.
SB: sleep bit. Indicates if the vehicle bus is in standby mode.
Fault: the number of faults in the control module DTC memory.
Subsystems are also displayed. Control modules that have subsystems, meaning secondary control modules, are
marked with a +. Clicking on it shows the subsystems. The first level is shown by default. The example shows the
diagnostic interface that serves as the primary control module to all of the other secondary control modules.
Control modules in which faults have occurred are shown in red. The number of faults is also shown in the "Fault"
column.
Control modules that are coded as installed but could not be addressed are shown in bold, red font:
Figure 7.72. Display when there is faulty communication with a control module
The components list can be updated manually or in cycles. To update manually one time, click the now button.
If the user decides to update in cycles, the table updates continuously according to the interval shown in the text
field below the option. The value is entered in seconds. If the interval is smaller than the time needed for the update,
the reading will begin again immediately after a the current reading cycle ends. The interval can be changed during
the update cycle. Use the Return key to confirm the new value. To end the update cycle, clear the check mark next
to the Cycle option. You can also update the table between cycles by clicking the now button.
7.4.4. OBD
Different OBD services can be performed using OBD functions and the vehicle OBD functions are checked.
This occurs in three steps:
•
The OBD function is selected
•
The OBD parameter is selected
•
The results are displayed
1.
The OBD functions are selected
214
OBD mode
Figure 7.73. The OBD function is selected
As soon as the list of OBD functions is selected, the
is active.
switches to the next view of the OBD parameter selection.
2.
The OBD parameter is selected
215
OBD mode
Figure 7.74. The OBD parameter is selected
In this view, the Parameters belonging to the OBD function are selected, which are displayed when the
function is being performed.
In the left list,
the available parameters are displayed. The list on the right
parameters. It is empty in the beginning.
contains the selected
The actuators can be filtered in the Filter entry field. are entered in the filter field, then only the parameters
are displayed, that contain the name of the text or partial text.
Show all: By default only the parameters are shown, that are identified as being supported by the vehicle. If
Show all is selected, then all parameters are shown.
When you click on a parameter in either of the lists, the buttons to move that actuator become active.
Moves the selected parameter to the left list
Moves the selected parameters to the right list
.
.
Moves all parameters to the left list.
Moves all parameters to the right list.
The list of selected parameters
can be sorted:
Moves the selected entry up one position.
216
OBD mode
Moves the selected entry down one position.
Note:
The parameters can also be selected with the keyboard. For additional information on using the keyboard,
refer to the table Keyboard Shortcuts.
switches to the result display.
Switches back to the previous view.
3.
OBD result display
Figure 7.75. OBD result display
The OBD function in this view. The results parameters are shown in a table in three columns:
Measurement name: The name of the OBD functionality or of the parameter.
Value: the measured value.
Adr.: The control module diagnostic address that has sent the value.
The answers from the control modules are shown hierarchically structured, sorted by diagnostic address.
If a control module does not answer, even though the OBD function supports it, this will displayed in the
Value column as as as text "no answer from control module". The text also appears if an answer is erroneous.
These texts appear in red.
217
OBD mode
If the user decides to update in cycles, the table updates continuously according to the interval shown in the
text field below the option. The value is entered in seconds. If the interval is smaller than the time needed for
the update, the reading will begin again immediately after a the current reading cycle ends. The interval can
be changed during the update cycle. Use the Return key to confirm the new value. To end the update cycle,
clear the check mark next to the Cycle option. You can also update the table between cycles by clicking the
now button.
Switches to the previous view.
7.5. End self diagnosis
OBD can be ended if the OBD functions are closed.
To end the flash session, you must switch to the Control Modules tab.
Figure 7.76. Ending the Flash Session
Clicking this button begins the process of exiting the OBD. You must confirm the prompt that follows.
Figure 7.77. End self diagnosis
218
OBD mode
Yes: OBD ends.
No: OBD does not end.
If, during OBD, result data were entered into the OBD log and they were not saved manually, then the user has
the possibility, to save the log. In this case, another inquiry appears:
Figure 7.78. Saving the OBD log
Yea: The OBD log is saved under the previously selected file name or under the file name configured in the
Admin area. OBD ends.
No: OBD ends and the protocol is discarded.
Offboard Diagnostic Information System Service then returns to the start page in the OBD mode.
219
Chapter 8. Flashing Mode
In addition to diagnosis, Offboard Diagnostic Information System Service also offers the ability to flash.
The process used in Flashing mode is very similar to Diagnosis mode, but it is less comprehensive overall. Guided
Fault Finding and control module functionalities are not available in this mode.
Figure 8.1. Work Process in Flashing Mode
•
When entering the flashing process, the vehicle is connected to the tester and identified, login to the group
systems is completed, an order is selected for the session and the control modules are identified.
•
The flash programs determined for the vehicle can then be performed.
•
The flash session ends when the desired flash work is complete.
220
Flashing Mode
8.1. Start flashing
In the Starting flashing section, the vehicle is connected to the tester and flash entry begins.
Figure 8.2. Starting Flashing Section
Flashing is available after selecting Flashing mode.
The chapter Starting diagnosis describes the process of connecting the vehicle in detail.
Note:
For details on vehicle identification, refer to "Starting Diagnosis".
Notice:
Some diagnostic connections, such as radio connections, cannot be used for flashing for legal reasons. If an
unpermitted diagnostic connection is used for flashing, Offboard Diagnostic Information System Service gives
a warning message and requests the user to use a legally permitted connection.
Note:
For a detailed description on changing diagnostic hardware, refer to "VCI.
221
Flashing Mode
Flashing entry can begin once a permitted diagnostic connection is selected and the vehicle is connected.
Figure 8.3. Flash entry start window
Click Start flashing to begin flash entry.
222
Flashing Mode
8.2. Identifying the Vehicle
The vehicle is identified once flash entry starts.
Figure 8.4. Identifying the Vehicle Section
Offboard Diagnostic Information System Service first tries to analyze the vehicle automatically.
Figure 8.5. Vehicle Analysis during Flash Entry
If the vehicle is recognized completely, meaning the VIN, brand, model and model year are clearly recognized,
vehicle identification will run completely automatically without displaying the vehicle features dialog.
223
Flashing Mode
If the automatic vehicle identification fails, Offboard Diagnostic Information System Service displays a vehicle
features dialog with entries for VIN, Manufacturer, Model and Model year.
Figure 8.6. Manual vehicle identification
The defining vehicle features can be selected manually in this dialog.
Transfer: the selected vehicle features are transferred and flash entry continues.
Cancel: vehicle identification is cancelled.
Note:
For a detailed description of the basic information dialog, refer to "Vehicle Features Dialog".
When referring to that section, keep in mind that the vehicle features dialog is not as detailed for flash entry.
You can switch between manual and automatic vehicle identification.
224
Flashing Mode
Figure 8.7. Automatic Vehicle Identification
For example, the VIN can be entered and then the identification, if necessary, can run automatically. In automatic
identification, the features with a gray background cannot be changed.
Transfer: the flash entry continues.
Cancel: vehicle identification is cancelled.
Vehicle identification ends.
8.3. Group Systems Login
The next section of the flash entry includes logging into the group systems.
Figure 8.8. Logging in to Group Systems Section
Offboard Diagnostic Information System Service opens a login window in order to log in.
225
Flashing Mode
Figure 8.9. Group Systems Login Window
The login is required once per session. The global user ID and password for group systems access are required
to log in.
Transfer: the login data are sent to the group systems.
Cancel: the login data are discarded. Authorized dealers can repeat the login at any time.
This button is available in all views of Offboard Diagnostic Information System Service that use data from
the group systems. It can be used to log in again at any time.
Notice:
Offboard Diagnostic Information System Service make Diagnosis and Flashing available only to licensed
markets.
You can check the license content in the Administration area:
Refer to "Administration/General/License Info"
An independent market operator must log in to the group systems at the beginning of a diagnostic or flash
session online.
If the login is interrupted, Offboard Diagnostic Information System Service will return to the start screen.
After logging in successfully, Offboard Diagnostic Information System Service shows the remaining period of
validity for the flat rate in days and hours under Remaining runtime in the Information area of the application
interface. See illustration information area.
The independent workshops do not have access work orders and History.
Note:
Refer to "Login to Group Systems"
226
Flashing Mode
.
8.4. Order Selection
After logging into group systems, an order is selected or created manually for the flash session.
Figure 8.10. Selecting an Order Section
If the login is successful, Offboard Diagnostic Information System Service accesses the order data for the
current vehicle from ElsaPro.
227
Flashing Mode
Figure 8.11. Selecting an Order for Flashing
Offboard Diagnostic Information System Service switches to the Orders tab and shows a list of all available
orders for the vehicle.
In the work order list, the work order number is displayed under Work order, the current status in the service core
process is displayed under SCP status, and the vehicle license plate number, the deadline for the work order
and descriptive text about the work order are also displayed.
The table that follows lists the meaning of the SCP status numbers.
SCP Status No.
Meaning
1
Appointment scheduling
2
Appointment preparation
3
Vehicle drop-off
4
Performing work
5
Quality control
6
Vehicle return
7
Follow-up
8
Completed
Table 8.1. Meaning of the SCP Status Numbers
If an order from ElsaPro will be used, the desired order must be marked here.
228
Flashing Mode
Select order: clicking this button continues flash entry with the order from ElsaPro.
An order can also be added manually. Standard order for working with a manual order number is selected
in the list first.
Enter number... : Clicking this button opens a window for entering the manual order number.
Select order: flash entry continues with the manual order.
No order: if you will be working without an order, click this button to continue flash entry.
Note:
Refer to "Selecting an Order".
This completes the order selection.
If Offboard Diagnostic Information System Service is configured in this way, then the control modules must
now be identified. Otherwise the special functions tab opens. This tab displays the list of flash programs that can
be used for the vehicle.
8.5. Identifying control modules
The vehicle control modules are identified after selecting the order. This step is optional and it happens only if
Offboard Diagnostic Information System Service was configured this way.
Figure 8.12. Identifying Control Modules Section
Offboard Diagnostic Information System Service shows a progress indicator for the control module identification.
Figure 8.13. Control Module Identification
Cancel flash entry: The flash entry is cancelled.
229
Flashing Mode
Once control module identification is complete, Offboard Diagnostic Information System Service opens the
Special functions tab and displays the flash programs that are available for the identified vehicle in a table.
8.6. Working with Flash Programs
After identifying the control modules, flash programs can be run.
Figure 8.14. Running Flash Programs Section
Offboard Diagnostic Information System Service lists the available flash programs on the special functions tab.
Figure 8.15. Available Flash Programs
230
Flashing Mode
Clicking the desire flash program marks it.
The test programs are grouped by theme.
Perform test...: the highlighted flash program is started. Offboard Diagnostic Information System Service
switches to the Operation tab.
Display documents: this button can be used to display associated documents, if available. Offboard Diagnostic
Information System Service then switches to Information mode, Documents tab.
The flash programs run the same way the GFF diagnostic programs run.
Note:
Refer to "Working with GFF".
Flash sessions can be saved and then opened again and continued just like diagnostic sessions. The application
detects automatically if a diagnostic or flash session should be saved or resumed.
Note:
For detailed information on saving flash sessions, refer to "Data.
8.7. Diagnostic objects when flashing
In addition to the flash programs, additional functions or GFF programs, which are relevant for the vehicle, can
appear in the special function tab. These can then be performed as the other tests.
In some cases, not all the basic features needed to perform the special function or GFF program, were transmitted
during the flash entry. If the basic features are missing, then the user will see a dialog when performing such a
test that allows the user to add the missing basic features.
Figure 8.16. Basic features manual selection
The model year, version and engine can always be accessed in this dialog. The dialog will not appear if one of
these criterion was already identified. The dialog will not appear if all the criteria were already identified.
OK: Accepts the selection and ends the dialog.
The special function or the GFF program for identifying the diagnostic objects needs more information about the
equipment network. If this is the case, a dialog is displayed where the user is requested to complete any missing
equipment characteristics. The control module can tell which version is installed, or, if the control module is
installed or not.
231
Flashing Mode
Figure 8.17. Manual control module selection
The following is an example of a dialog. Which available characteristics that are actually displayed depends on
the current equipment network and the on the diagnostic objects contained in the knowledge base.
OK: Accepts the selection and ends the dialog.
Using this information, the diagnostic objects determined as relevant for the vehicle and as the last elements will
appear in the special function tab.
The elements run the same way the GFF diagnostic programs run.
Note:
Refer to "Working with GFF".
8.8. End flashing
The flash session ends when the desired flash programs are complete.
Figure 8.18. Ending Flashing Section
To end the flash session, you must switch to the Flashing tab.
232
Flashing Mode
Figure 8.19. Ending the Flash Session
Clicking this button begins the process of exiting the flash session. You must confirm the prompt
that follows.
Figure 8.20. Ending the Flash Session
Yes: the flash session ends.
No: the flash session does not end.
Depending on the vehicle, end module programs may run here just as they do when exiting Guided Fault Finding.
It is also possible to send a feedback about a flash session. The feedback can also be skipped.
Offboard Diagnostic Information System Service then returns to the start page in the Flashing mode.
Note:
For detailed information on exiting Guided Fault Finding, refer to "Ending Diagnosis".
233
Chapter 9. Info mode
The Information mode combines all functions that provide information. Most of the information is provided by
Volkswagen group systems, so an active connection with a valid login is especially important here.
Clicking this button switches to Information mode. You can switch from any other mode,
but the requirement is that a diagnostic entry or flash entry must have taken place. The login to the group systems
can be completed later.
Note:
The contents of the following tab are provided through group system services. A login to the group systems once
per diagnostic session and an online connection to the network are required.
Using the buttons
and
, you can scroll back or forward if the content has multiple pages.
The buttons
allow you to reload the content and allow authorized dealers to repeat the login. When reloading,
the window home page loads.
Figure 9.1. Tabs in Information mode
The following tabs are available in the Information mode:
"Documents"
"Campaigns"
"History"
"Wiring Diagrams"
"Manuals"
"Vehicle"
"PR no."
You can open any tab by clicking on it.
234
Info mode
9.1. Documents
Offboard Diagnostic Information System Service makes a wide variety of documents available. These documents come from the knowledge bank in the diagnostic database and are based on the vehicle being diagnosed
and its equipment versions.
Documents can also be opened in the Diagnosis or Flashing modes. Offboard Diagnostic Information System
Service switches automatically from the Diagnosis or Flashing mode to Information mode.
Note:
Refer to "Working with GFF".
Notice:
The document tree display on the Documents tab is only available once diagnostic or flash session has been
completed, because the documents are only assembled for the vehicle that is being diagnosed.
After switching to the Information mode for the first time, the Documents tab opens. After that, the system
switches to the last active tab when switching to the Information mode.
Figure 9.2. Information Mode Entry View
Vehicle documents: clicking this button displays all of the documents available for the entire vehicle in a tree
structure in the Documents tab.
235
Info mode
Figure 9.3. Selecting a document to display
In the tree structure, individual branches can be opened or closed by clicking the plus sign [+] or minus sign [-].
After marking a document listed in the tree structure with the mouse, the button for displaying the document
appears.
Show document: the marked document opens.
The document can also be opened by double-clicking directly on the document tree.
236
Info mode
Figure 9.4. Viewing a document
clicking this button returns to the document structure.
There are documents that contain only text or illustrations as well as documents that combine text and illustrations.
The combined text-illustration documents are displayed next to each other.
The following are two examples of typical vehicle documents.
Example 1 for a text document.
237
Info mode
Figure 9.5. Example 1, document tree
Selection of: Suspension - Repair Manual - General Information on Checking Wires
238
Info mode
Figure 9.6. Example 1, document view
Example 2 for a combination text/illustration document:
Figure 9.7. Example 2, document tree
Selection of: Body - Specified Values - Headlamp Adjustment
239
Info mode
Figure 9.8. Example 2, document view
There are Hot Spots in illustration documents. Hot spots are areas of the illustration that are outlined in red.
Figure 9.9. Document with Hot Spot
Clicking a Hot Spot opens another illustration with a more detailed view of the area that was outlined in red.
240
Info mode
Figure 9.10. Open Hot Spot
Documents can be printed out in the current view.
Note:
Refer to "Current View".
241
Info mode
9.1.1. Documents in GFF
There are a number of different documents for the Guided Fault Finding test programs. These documents are
available in Diagnosis mode, either in the test plan view or in the test programs themselves.
Note:
Refer to "Working with GFF".
Figure 9.11. Displaying documents for a test plan
Documents: clicking this button on the Test plan tab in Diagnosis mode opens a context menu where you can
select if documents should be displayed for a test plan or a test program:
Test plan documents: all documents related to diagnostic objects contained in the test plan are provided in a
tree structure.
Test program documents: all documents related to diagnostic objects contained in the test program that is marked
are provided in a tree structure.
242
Info mode
After selecting the document type, Offboard Diagnostic Information System switches from the Test plan tab in
Diagnosis mode to the Documents tab in Information mode.
Documents for the test programs contain the following content. The test program determines which documents
are available.
Block diagram
CD content file
Adjusting guidelines
Component location
Function description
Function test guide
Measuring equipment
Pin assignment
Fuse assignment
Connector view
Tools
Wiring diagram
Repair manual
Note:
Additional documents are located under the Repair manual and Wiring diagram tabs.
Note:
Refer to "Repair Manual Tab" and "Wiring Diagram Tab".
Switch back to the Diagnosis mode to return to the test plan.
243
Info mode
9.2. Campaigns tab
Clicking the Campaigns tab displays field campaigns that were already performed on the vehicle, for example
recall campaigns.
Figure 9.12. Campaigns tab view
Go forward one page.
Go back one page.
This button allows you to reload the content. Authorized dealers can log into the group systems again here.
244
Info mode
9.3. History tab
The History tab displays the vehicle repair history from ElsaPro. The ElsaPro manual provides detailed information on the list of content.
Figure 9.13. History tab view
Go forward one page.
Go back one page.
This button allows you to reload the content. Authorized dealers can log into the group systems again here.
245
Info mode
9.4. Manuals tab
Repair manuals can be accessed on the Manuals tab.
Figure 9.14. Manuals tab view
The documents are listed in the left window in a tree structure based on the VIN. Clicking the desired manual
displays it in the right window.
Go forward one page.
Go back one page.
This button allows you to reload the content. Authorized dealers can log into the group systems again here.
246
Info mode
9.5. Wiring diagrams tab
Required wiring diagrams can be accessed on the Wiring diagrams tab.
Figure 9.15. Wiring diagrams view
The diagrams are displayed in a tree structure in the left window. Clicking the desired wiring diagram displays
it in the right window.
Go forward one page.
Go back one page.
This button allows you to reload the content. Authorized dealers can log into the group systems again here.
247
Info mode
9.6. Vehicle tab
All relevant vehicle details are shown on the Vehicle tab. Diagnostic entry must be completed.
The details displayed are:
VIN
Manufacturer
Type
Model year
Production location
Serial number
Engine code
Transmission code
Sales number
Sales code
Production date
248
Info mode
Figure 9.16. Vehicle view
This button allows you to reload the content. Authorized dealers can log into the group systems again here.
249
Info mode
9.7. PR no. tab
The equipment numbers for the selected vehicle are displayed in the table on the PR no. tab. Diagnostic entry
must be completed first.
Figure 9.17. PR no. view
This button allows you to reload the content. Authorized dealers can log into the group systems again here.
250
Chapter 10. Virtual Keyboard User
Guide
10.1. Installation
Administrator rights are required for the installation. The "Virtual Keyboard" installation can be accessed without
a graphic user interface. In Table 10.1, “Installation Parameters” the supported parameters are listed.
/VERYSILENT
Suppressing the graphic user interface
/DIR=Directory
The directory where the "Virtual Keyboard" should be installed
/UNINSTALL
Removal of the "Virtual Keyboard"
Table 10.1. Installation Parameters
Table 10.2, “Install Return Values” contains the installer return values
0
No error
1
No administrator rights
7
Not enough memory space on the drive
Table 10.2. Install Return Values
During the installation, a system service that starts the "virtual keyboard" is installed. This service also monitors
if the "virtual keyboard" is running. If an application ends it, the "virtual keyboard" service starts again.
10.2. Software
The "virtual keyboard" runs under Windows XP with Service Pack 2 installed. It emulates a normal keyboard that
would be connected via USB or PS/2. The "virtual keyboard" program sends keyboard information to the active
application just as it is sent from a real keyboard.
The "virtual keyboard" starts as soon as the login screen appears. A symbol in the toolbar (refer to Figure 10.1,
“Toolbar symbol”) in the active application will display or hide the keyboard.
Figure 10.1. Toolbar symbol
10.2.1. User interface
When the "virtual keyboard" is displayed, it is always in the foreground. It is transparent so you can still see the
applications behind the keyboard. The "virtual keyboard" has no toolbar, no system menu and no minimize/maximize button. There are I+ME buttons that can be used to change the capitalization, type (numerical or normal
keyboard) and transparency of the keyboard.
251
Virtual Keyboard User Guide
Figure 10.2. Keyboard Layout
Figure 10.3. Numerical Keyboard
The I+ME buttons mean:
Display the settings dialog
Minimize the keyboard
Maximize the keyboard
Display the numerical keyboard
Hide the numerical keyboard
Table 10.3. I+ME Buttons
10.2.1.1. Keyboard Size
You can change the size of the keyboard using two buttons. The size of the buttons and characters automatically
adapts when the size of the keyboard changes. You cannot make the keyboard larger than the size of the screen.
If you try to move the keyboard off the screen, it will move back onto the screen. If you hide and then show the
keyboard again, it will display in the size and location that it last appeared.
252
Virtual Keyboard User Guide
The size of the "virtual keyboard" is maintained but the location is not. That means the "virtual keyboard" will
display in the center at the same size that was used last time when the user displays the keyboard for the first
time after restarting.
10.2.1.2. Special Function Keys
If you press a special function key (SHIFT, CTRL, etc.), this key is marked. The marking is removed the next
time you press a key normally.
The current active characters are displayed on the keys and the layout changes when you press a special function
key. In Table 10.4, “Changing Characters” the different display for the "<" key is shown as an example.
Normal
After SHIFT is pressed
After ALTGR is pressed
Table 10.4. Changing Characters
10.2.1.3. Settings Dialog
The transparency of the "virtual keyboard" can be adjusted in the settings dialog. The possible values are within
the 0% (no transparency) to 90% (almost completely transparent) range. The keyboard changes the transparency
when you move the slider.
The changes are accepted when you press the OK button. Pressing the reset button restores the settings that were
active when the window opened.
Figure 10.4. Settings Dialog
10.2.2. Languages
The keyboard layout changes the display depending on the current input language. If a language is not supported,
the US English keyboard is displayed instead.
The following languages are supported:
253
Virtual Keyboard User Guide
Bulgarian
Chinese (simplified)
Danish
German (Germany)
English (Great Britain)
English (USA)
Farsi
Finnish
French (France)
Greek
Italian (Italy)
Japanese
Korean
Croatian
Dutch
Polish (programmer)
Portuguese
Romanian
Russian
Swedish
Slovakian (QWERTY)
Slovenian
Spanish
Taiwan (Bopomofo)
Taiwan (ChaJei)
Thai (Kedmanee)
Czech
Turkish (Turkish Q)
Hungarian
Table 10.5. Supported Languages
10.2.3. Keyboard Layouts
10.2.3.1. German
254
Virtual Keyboard User Guide
10.2.3.2. Bulgarian
10.2.3.3. Chinese simplified
255
Virtual Keyboard User Guide
10.2.3.4. Danish
10.2.3.5. English GB
256
Virtual Keyboard User Guide
10.2.3.6. English USA
257
Virtual Keyboard User Guide
10.2.3.7. Farsi
10.2.3.8. Finnish
258
Virtual Keyboard User Guide
10.2.3.9. French
259
Virtual Keyboard User Guide
10.2.3.10. Greek
260
Virtual Keyboard User Guide
10.2.3.11. Italian
261
Virtual Keyboard User Guide
10.2.3.12. Japanese
10.2.3.12.1. Direct input
10.2.3.12.2. Hiragana
262
Virtual Keyboard User Guide
10.2.3.12.3. Katakana
10.2.3.13. Korean
10.2.3.13.1. English
263
Virtual Keyboard User Guide
10.2.3.13.2. Hangul
10.2.3.14. Croatian
264
Virtual Keyboard User Guide
10.2.3.15. Dutch
265
Virtual Keyboard User Guide
10.2.3.16. Polish
266
Virtual Keyboard User Guide
10.2.3.17. Portuguese
10.2.3.18. Romanian
267
Virtual Keyboard User Guide
10.2.3.19. Russian
268
Virtual Keyboard User Guide
10.2.3.20. Swedish
10.2.3.21. Slovakian
269
Virtual Keyboard User Guide
10.2.3.22. Slovenian
270
Virtual Keyboard User Guide
10.2.3.23. Spanish
271
Virtual Keyboard User Guide
10.2.3.24. Taiwan (Bopomofo)
10.2.3.25. Taiwan (ChaJei)
272
Virtual Keyboard User Guide
10.2.3.26. Thai
273
Virtual Keyboard User Guide
10.2.3.27. Czech
10.2.3.28. Turkish
274
Virtual Keyboard User Guide
10.2.3.29. Hungarian
275
Virtual Keyboard User Guide
276
Chapter 11. Administration Mode
11.1. Operation
Various Offboard Diagnostic Information System Service settings can be configured in Administration mode.
The following view is visible after clicking the Admin button.
Figure 11.1. Administration window
The administration view contains five tabs for system settings that are arranged according to areas. These tabs are:
•
General
System-based settings such as language or update mode are managed here.
•
Save locations
The save locations for system and work data are selected here.
•
Support
The support settings are managed here.
•
Connections
277
Administration Mode
The connections to individual group systems services are managed here.
•
Certificate
The necessary certificates for internet access are linked here to the individual group systems services.
•
Test baseline
The test environment can be configured here.
The listed settings options are located within this tab.
To make changes, click the desired settings in the left selection window to make a selection. The configuration
options are in the right window.
Saved changes can be reset to their default factory settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
Notice:
Changing system settings can interfere with the use of Offboard Diagnostic Information System Service. The
configuration should only be changed if requested by support. The user is responsible for any changes made that
are not recommended by support.
The following administration areas are available:
"General / Brand Design"
"General / Language"
"General / Update"
"General / System Logging"
"General / System Environment"
"General / License Information"
"General / Global Configuration"
"General / GFF Process"
"General Information / Keyboard Settings"
"Save Locations / Database"
278
Administration Mode
"Save Locations / Diagnostic Session"
"Save Locations / Flash Paths"
"Save Locations / Diagnostic Log"
"Support / Contact Data"
"Support / E-mail Outbox Server"
"Connections / Brand Settings"
"Connections / Group System: GFF"
"Connections / Group System: ElsaPro"
"Connections / Group System: Carport"
"Connections / Group System: DISS"
"Connections / Group System: eShop"
"Connections / Mirror Server 2"
"Certificates / Client Certificates"
"Certificates / Trust Certificates"
"Test baseline / data configuration"
279
Administration Mode
11.2. General Area
General / Brand Design
In this area, the Offboard Diagnostic Information System Service graphic interface can be adapted to a specific
group brand.
Figure 11.2. Selecting the Design
Use the selection lists for details on brand design.
Designs for the following brands can be selected: Volkswagen, Audi, Bentley, Seat, Skoda, Lamborghini.
In addition, Neutral and Dynamic are available.
When Neutral is selected, Offboard Diagnostic Information System Service displays with a neutral logo regardless of the brand.
The dynamic design matches to the brand automatically identified during the diagnostic entry, so long as there is
a design for this brand. Otherwise the neutral design is used.
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
280
Administration Mode
Clicking the Save button saves the changes made.
General / Language
The Offboard Diagnostic Information System Service language can be changed using the language list field.
Figure 11.3. Language setting
The desired language can be selected in Language details in the Language list.
The default selection is Automatic, meaning the language matches the tester operating system.
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
281
Administration Mode
Note:
Only the user interface language changes. If documents are available in the selected language, they will be displayed in the new language that was set. Otherwise the documents remain in the installed language.
The following steps are necessary to use Offboard Diagnostic Information System Service in different languages
(especially East Asian characters):
In the Windows operating system, open Control Panel -> Regional and Language Options.
Figure 11.4. Additional Windows language support
On the Languages tab, activate the options in the Additional language support area.
OK: the changes are made and the window closes.
Cancel: the changes are not made and the window closes.
Transfer: the changes are made but the window does not close.
282
Administration Mode
Figure 11.5. Windows language display codes
In the Expanded tab, activate all Code page conversion tables.
In the Expanded tab, activate the Standard settings for user accounts.
OK: the changes are made and the window closes.
Cancel: the changes are not made and the window closes.
Transfer: the changes are made but the window does not close.
Restart the system. The languages are then available.
283
Administration Mode
General / Update
The cycle that Offboard Diagnostic Information System Service uses to check for updates on the mirror server
2 can be set in Update details.
Figure 11.6. Update view
Load in background: When this option is activated, Offboard Diagnostic Information System Service download program updates in the background, if there are any. For performance reasons, downloading the in background
pauses when a diagnostic session starts. The same applies if there is not enough memory available for the update.
Temporary download folder: This is used to specify the folder where the program updates will be stored temporarily until they can be installed. The path to the folder can either be entered manually or browsed for in the
folder system by pressing the Browse... button.
Checking schedule: With this option, the user can specify if the program should check for updates according to
a cycle, meaning each time a certain number of days passes, or always on the days of the week that are indicated.
Cycle (in days, 1-7): Only relevant if Cycle was selected as the schedule to check for updates. 1 is entered in this
field as a default. That means the system will check for available program updates each day starting from the first
time the program is started. The desired update cycle can be entered here in days. For example, enter the number
5 to check for updates every five days. The cycle cannot be more than 7 days.
Days of week for updates: Only relevant if On certain days of the week was selected as the schedule to check
for updates. The desired day of the week to check for updates is selected here. Multiple days or all days of the
week can be selected.
284
Administration Mode
If no day was selected, a note about this will display when the program automatically checks for updates every day.
Figure 11.7. Configuration error when checking for updates
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
285
Administration Mode
General / System Logging
The content of the system logging can be determined in a selection window. The system logging is written in a
log file that is sent with the feedback.
Figure 11.8. System configuration view
If the feedback support team requires more detailed information, the content can be set in System logging details
under Settings.
The selection:
•
All
contains all log contents listed here. This file is the largest, so transferring it can take the longest.
•
Information
Contains log contents with information.
•
Warnings
Contains log contents with warnings.
•
Error
286
Administration Mode
Contains log contents with errors.
•
Serious error
Contains log contents with serious errors.
The scope of log information that is recorded can range from "serious errors" up to "all". A detailed log output
can result in loss of performance.
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
General / System Environment
This area provides information on Offboard Diagnostic Information System Service system settings.
Figure 11.9. System environment view
287
Administration Mode
System environment details shows
•
the system path to the application directory,
•
the software and data versions,
•
the save location of the DIDB DB Basis database,
•
the version of the ECP,
•
and the manufacturer and versions of the external diagnostic applications MCD server and PDU API.
The information here cannot be changed. This view is only to provide information.
General / License Information
This view displays all of the details about the license.
Figure 11.10. License Information Part 1 View
288
Administration Mode
Figure 11.11. License Information Part 2 View
The following licensing information is displayed:
•
Versions of the product and brand,
•
the license file's expiration date, serial number and save path,
•
the country code under information,
•
the importer and dealer numbers as well as dealer type under licensed brand(s),
•
the hardware ID and tester type under hardware,
•
the version of the start program under launcher.
This is only for general information. The settings cannot be changed.
Note:
Refer to the note in "Diagnostic Entry".
289
Administration Mode
General / Global Configuration
In the global configuration, all tester devices (testers, notebooks) access the same configuration file so all devices
have the same settings.
Figure 11.12. Global configuration view
The global configuration file must be saved in a previously selected path in the local network.
Select: a path can be set on individual testers under global configuration directory using this button.
Use global configuration: This is used to determine if the tester will use the global configuration settings if a
corresponding file was specified in the directory described above.
Change global configuration: here you select if the tester configuration file should be written into the global
configuration directory. If so, the global configuration data will be overwritten.
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
290
Administration Mode
Clicking the Save button saves the changes made.
Notice:
If no global configuration data is selected, Offboard Diagnostic Information System Service will use the available local configuration settings.
General / GFF Process
The list of individual test steps on the left side in the procedure view of Guided Fault Finding can be displayed
or hidden.
Figure 11.13. GFF procedure details view
Always display test steps: activating this setting displays the test steps. Otherwise the list of test steps is hidden.
Saved changes can be reset to their default settings with the Reset button.
291
Administration Mode
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
General Information / Keyboard Settings
You can switch the virtual keyboard usage on or off.
Figure 11.14. Virtual Keyboard Detailed View
Use virtual keyboard: activating this setting switches the virtual keyboard on. Otherwise, the virtual keyboard
is switched off.
If the virtual keyboard is switched on, it appears automatically if keyboard input is required in Guided Fault
Finding test programs.
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
292
Administration Mode
Clicking the Save button saves the changes made.
General / Dealer Data
The dealer data display in the diagnostic log can be configured here.
Figure 11.15. View of the dealer data details
Facility ID: dealer data, which can be found in the diagnostic log in the "facility ID" field, can be entered in
this field.
It is possible to enter a free text without any limitation to length and with line breaks. If the field stays empty, then
nothing will appear in the "facility ID" field in the diagnostic log.
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
293
Administration Mode
11.3. Save Locations Area
Save Locations / Database
The save location of the diagnostic database can be set in this area.
Figure 11.16. Database Directory
Select: in database details, this button can be used to select the save location of the database directory in the
Windows file system.
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
294
Administration Mode
Notice:
This path may only be changed with consent from support. Otherwise, the vehicle diagnostic data will no longer
be available.
If the database will be copied to a different location, the new path must be entered here.
Save Locations / Diagnostic Session
The save location and file name specification for the diagnostic session data can be preset in this area.
Figure 11.17. Diagnostic Session Save Location
Select: using this button, the specified save location for the diagnostic session data in the Windows file system
can be selected in the Target directory field under Diagnostic session details.
During a session, it is possible to save the session data to a different location using the Windows save dialog.
File name pattern: a naming pattern for the diagnostic session can be selected in this field.
In the example shown, the file name consists of the VIN, date with four-digit year and two-digit month and day
and the exact time WVW12345678901234_2009-08-12_16-27-15.ses.
295
Administration Mode
The following inputs are possible:
• %YYYY#for the current year
• %MMM#for the current month
• %DD#for the current day of the month
• %hh#for the current time of day in 24-hour format
• %mm#for the current minute in the hour
• %ss#for the current second in the minute
• %VIN#Vehicle Identification Number of the vehicle being diagnosed
• free text that may consist of the following characters:
• capital and lower case letters
• all numbers from 0 - 9
• the following characters: _(underscore) -(minus) .(period)
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
Notice:
There must be a save location to save session data.
296
Administration Mode
Save Locations / Flash Paths
In this area, the file paths through which Offboard Diagnostic Information System Service loads flash files
are set.
Figure 11.18. Flash paths view
Select: in Flash path details under Flash paths, this button is used to set the path to the flash files in the Windows
file system for Path 1 (CDROM) and Path 2 (hard drive). Local flash files can be stored under these paths and
prepared for flashing.
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
The path entered manually must conform to Windows specifications:
CDROM drive letter:\Flash data or
297
Administration Mode
Drive letter:\Folder name\Flash data
Notice:
If there are not valid paths entered here, local access to flash files is not possible.
Save Locations / Diagnostic Log
The save location and the name for the Guided Fault Finding logs in the Windows file system are established in
this area. Offboard Diagnostic Information System Service suggests a default setting for both logs.
Figure 11.19. Diagnostic log view
Select: In diagnostic log details, the save location for the log can be entered under Guided Fault Finding log
as well as underOBD log in the target directory field.
During a session, it is possible to save the log data to a different location using the Windows save dialog.
File name pattern: a naming pattern for the log can be selected in this field. In the example, the file name for the
Guided Fault Finding log is made up of the VIN, the date with a four-digit year, a two-digit month and day and
the exact time WVW12345678901234_2009-08-10_14-32-34_dprot.
298
Administration Mode
The following inputs are possible:
• %YYYY#for the current year
• %MMM#for the current month
• %DD#for the current day of the month
• %hh#for the current time of day in 24-hour format
• %mm#for the current minute in the hour
• %ss#for the current second in the minute
• %VIN#Vehicle Identification Number of the vehicle being diagnosed
• free text that may consist of the following characters:
• capital and lower case letters
• all numbers from 0 - 9
• the following characters: _(underscore) -(minus) .(period)
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
Note:
With default settings, the log is saved with the VIN in the file name to prevent confusion.
Auto save: This is where you can choose the intervals, in which the Guided Fault Finding log should be saved in
a specified location automatically. The default value is every 5 minutes.
When OFF is selected from the list, then the diagnostic log is not automatically saved.
299
Administration Mode
11.4. Support Area
Support / Contact Data
The data for the support contact person is entered here.
Figure 11.20. Support view
The contact person and his or her address for support feedback is entered here in Contact data details under
Contact data for feedback.
Possible information includes:
•
First name
•
Last name
•
E-mail address (required)
•
Phone number (required)
The program will check for valid entries in the E-mail address and Phone number fields. If the information in
these fields is missing or invalid, the field will be marked with a red asterisk and the Save button will be inactive.
300
Administration Mode
The Automatic positive feedback field determines if a feedback should be sent after every diagnostic session for
statistical evaluation even if there is not a problem.
Off: automatic positive feedback is not sent.
On: automatic positive feedback is sent.
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
Note:
This information is necessary so that support can contact the right person if there are questions or responses.
Note:
Refer to "Support".
301
Administration Mode
Support / E-mail Outbox Server
The feedback mail connection to support is configured here.
Figure 11.21. E-mail Outbox Server View
Use the operating system's default e-mail client: If this option is activated, the e-mail program that is specified
as the default program will be used to send e-mail. The connection parameters for this e-mail program are used.
To use Offboard Diagnostic Information System Service to send e-mails, select the following options in the
"Outgoing mail server" section under Connection parameters:
•
Connection:
An e-mail is sent with every feedback - Mail settings,
The feedback is saved locally temporarily - QUEUE settings.
If you switch from QUEUE settings to Mail settings, Offboard Diagnostic Information System Service
sends the e-mails that were saved temporarily with the next feedback.
•
Mail server: name of the mail server.
•
Mail server port: the port for the mail server.
•
Mail server login: a checkmark can be entered here if a login to the mail server is necessary.
302
Administration Mode
•
Access name: the access name for the mail box that is entered here is assigned in the login window when
logging in.
•
Password usage:
The password is saved until Offboard Diagnostic Information System Service is ended. If the password
should be stored until Offboard Diagnostic Information System Service is closed, a login window in which
the user name and password are entered will open when sending a feedback.
The password only applies to the next time feedback is sent.
•
Secure connection: enter a check mark here if the mail server requires an SSL or TSL.
•
E-mail sender address: you can enter your own sender address here. This is necessary if support needs to
reply to the address.
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
If the e-mail is sent through the mail server from a provider, the provider specifications must be entered. The
provider will provide the necessary data such as mail server address, SMTP port and security settings. The user
name for the mailbox and the specified password must be used to log in.
If a network with its own mail server is used, it must be configured for SMTP (Simple Mail Transfer Protocol).
An older mail server that does not support this protocol (such as older versions of Microsoft Exchange) cannot be
used. The mail server administrator will provide the specifications required for configuring the outbox server.
Note:
Refer to "Support".
Notice:
The mail server configuration entries must conform exactly to the specifications. Free text such as mail server
information and the mail sender address is not checked. Incorrect entries will cause errors when sending feedback.
The e-mail outbox server does not support a proxy server for accessing the internet.
If using security software such as a firewall or anti-virus protection, make sure it does not block the mail sever
or the ports that are used.
The size restriction for e-mails that is set in the mail server must be followed. The provider or mail server administration can provide information about this. The size restriction should be changed, if necessary, if that is
possible. If an e-mail exceeds the size restriction, it will not be sent. Feedback e-mails with data attached can
reach sizes of 2 MB to 5 MB.
303
Administration Mode
Back end mail is sent through the JavaMail software standard library. If an error occurs within this software when
sending an e-mail, the error messages will only display the original text in English. In this case, the original text
in the error message will be referenced. There are exceptions to this:
If the mail server is entered incorrectly, the login appears with error message ODS9102E with a note about the
unknown mail server.
Figure 11.22. Error message about an incorrect mail server
The user name and password can be entered again.
Transfer: user name and password are transferred.
Cancel: the login is cancelled.
If a sender address is spelled incorrectly, the login appears with error messageODS9105E with a note about the
invalid sender e-mail address.
Figure 11.23. Error message about an incorrect sender address
The user name and password can be entered again.
Transfer: user name and password are transferred.
304
Administration Mode
Cancel: the login is cancelled.
11.5. Connections Area
Connections / Brand Settings
In this field, you can set the way each group brand connects to the group system, via CPN or Internet.
Figure 11.24. Brand Settings View
Brand to be configured: the brand whose settings will be configured in the Connection types tab in the following
views is selected in the Selection list. Only the brands that are licensed for the tester are available in this brand
selection.
Connection types: here you can select if a group system service is called up via CPN or an Internet address.
This setting can be specified individually for each brand.
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
305
Administration Mode
Clicking the Save button saves the changes made.
Notice:
The preset addresses for group system services can only be changed with agreement from support for the affected
brand. Otherwise, access is not possible.
Connections / Group System: Logon
The connection addresses for the Logon and DSS authentication services are configured in this field.
Figure 11.25. Group system view: Logon
All addresses being used for Logon and DSS authentication services are listed in the group system details: Logon
view.
•
DSS View
•
DSS Logon
•
Logon
Saved changes can be reset to their default settings with the Reset button.
306
Administration Mode
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
Offboard Diagnostic Information System Serves specifies addresses for these services.
Notice:
The authentication to the GFF and/or infomedia is not possible and these services cannot be used if an incorrect
address is entered here.
Connections / Group System: GFF
Network addresses for group services that Offboard Diagnostic Information System Service accesses can be
set in this field.
Figure 11.26. Group System: GFF
307
Administration Mode
The Group system details: GFF view lists all service addresses that are used in GFF test programs whose URLs
can be entered:
•
Pin Service
•
SVMService
•
RepairHints
•
ProtoService
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
Offboard Diagnostic Information System Serves specifies addresses for these services.
Notice:
If an incorrect address is entered here, GFF test programs cannot access the required group systems and, so they
will not run correctly.
308
Administration Mode
Connections / Group System: ElsaPro
The access data for services in the group system ElsaPro are configured in this field.
Figure 11.27. Group system ElsaPro view
To be able to display data from ElsaPro in Offboard Diagnostic Information System Service, the URLs in
group system details: ElsaPro for
•
vehicle history,
•
repair manuals,
•
technical service bulletins,
•
wiring diagrams and
•
field campaigns
must be entered.
The data required for logging into group systems
•
Brand (1 character)
309
Administration Mode
•
Country (3 characters)
•
Dealer ID (5 characters)
are taken from the license and are only displayed here.
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
Notice:
If these entries are not correct, either ElsaPro data cannot be accessed or the required login to the group systems
will fail.
310
Administration Mode
Connections / Group System: Carport
The connection address to Carport is configured in this field. Offboard Diagnostic Information System Service
provides an address.
Figure 11.28. Carport View
The URL for vehicle data through which this service is reached is entered under Group System Details: Carport.
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
311
Administration Mode
Notice:
If the URL is not entered correctly, the Carport service cannot be reached and vehicle data cannot be accessed.
Connections / Group System: DISS
The connection address to DISS is configured in this field. Offboard Diagnostic Information System Service
provides an address.
Figure 11.29. DISS View
The DissUrl for DISS, which is used to determine concerns, is entered under Group System Details: DISS.
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
312
Administration Mode
Clicking the Save button saves the changes made.
Notice:
If there is no correct DISS URL, concerns cannot be displayed from the DISS system or associated TSBs.
Connections / Group System: eShop
The connection address to the eShop is configured in this field. Offboard Diagnostic Information System Service provides an address.
Figure 11.30. Group system eShop view
The URL for the eShop service for automatic extensions of licenses obtained through the eShop is entered under
Group system details: eShop.
Saved changes can be reset to their default settings with the Reset button.
313
Administration Mode
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
Notice:
Without a correct URL for the eShop license update service, licenses cannot be extended automatically from
Offboard Diagnostic Information System Service. Without an automatic extension, the expired license must
be ordered in the eShop.
Connections / Mirror Server 2
Offboard Diagnostic Information System Service gets the files for update from Mirror Server 2.
Figure 11.31. Mirror server 2 view
The address of the local mirror server as it was set up on location for the workshop is entered in the mirror
server URL field.
314
Administration Mode
The mirror server user and mirror server password fields only need to be filled out if the local mirror server
was set up with a login. The local administrator can confirm if this is the case.
Timeout [s]: This is where the maximum wait time for answers from the Mirror Service are set. The default value
is 5 seconds.
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
11.6. Certificates field
Certificates that are needed for an encrypted SSL communication to the group system via the internet, can be
accessed and managed in the certificate field in the Administration mode. The certificates apply to all brands.
Two types of certificates are available. The following describes how to manage them:
1. Client certificate
2. Trust certificate.
315
Administration Mode
Certificates / Client Certificates
Client certificates have a public and private key. They are needed to authenticate the testers with the group system
servers using Offboard Diagnostic Information System Service.
Figure 11.32. Client certificates view
Client certificates can be imported in client certificate details view. Details can be displayed and removed here.
Client certificates are imported in the import certificates field:
Certificate: Click on
search and select the client certificate using Windows file management. Client
certificates have the file extension *.pfx or *.p12. The import button activates when a certificate is selected.
Password: The client certificate password must be entered here.
By clicking on
Service certificate memory.
the client certificate is added to the Offboard Diagnostic Information System
316
Administration Mode
Notice:
The following errors can occur while importing client certificates:
1. The hardware ID in the client certificate does not match the tester ID.
Figure 11.33. The hardware ID in the client certificate is incorrect
2. The client certificate has expired.
Figure 11.34. The validity period has expired.
3. The client certificate format is not supported. The X.509 format is required.
Figure 11.35. The format is not supported.
The client certificate can be viewed in detail in the available certificates field.
Name: Certificate alias name.
Valid starting: Validity start date.
317
Administration Mode
Valid through: Validity end date.
The detail view can be opened by selecting the client certificate and clicking on
.
Figure 11.36. Client certificate detail view
The following contents is displayed in the Details field:
Name: Client certificate alias name. CN=Name, OU= Organizational Unit, O= Organization, L=City, ST= State/
Province, C=country.
Owner: Owner of the client certificate.
Issuer: Issuer of the client certificate.
Valid starting: Validity start date.
Valid through: Validity end date.
Type: Client certificate format.
Issue Date: Issue date (import date) when the certificate was imported into the certificate memory.
318
Administration Mode
MD5 fingerprint: The fingerprint in MD5 format.
SHA-1 fingerprint: The fingerprint in SHA format.
Identification number: The client certificate identification number.
The certificate chain is displayed hierarchically in the certification path field. The selected client certificate is
the last one in the chain. Valid certificates are in green, invalid ones in red.
By clicking on
you leave the detailed view and return to the overview list.
If a client certificate is no longer needed, highlight it and click on
to delete it from the certificate
memory. It is necessary to confirm one more time when you erase a certificate.
Certificates / Trust Certificates
Trust certificates have a public key. A group system server identifies itself in the Offboard Diagnostic Information System Service tester as belonging to the VW corporation.
Figure 11.37. Trust certificate view
Trust certificates can be imported in trust certificate details view. Details can be displayed and removed here. All
trust certificates appearing in gray can be viewed in detail but cannot be removed. They are stored in the certificate
memory. Self-imported trust certificates appear in black and can be removed.
319
Administration Mode
Trust certificates are imported in the import certificates field:
Certificate: Click on
search and select the trust certificate using Windows file management. Trust
certificates have file extensions *.cer, *.der or *.pem. The import button activates when a certificate is selected.
By clicking on
vice certificate memory.
the trust certificate is added to the Offboard Diagnostic Information System Ser-
Notice:
The following errors can occur while importing trust certificates:
1. The trust certificate has expired.
Figure 11.38. The validity period has expired.
3. The trust certificate format is not supported. The X.509 format is required.
Figure 11.39. The format is not supported.
The trust certificate can be viewed in detail in the available certificates field.
Name: Certificate alias name.
Valid starting: Validity start date.
Valid through: Validity end date.
The detail view can be opened by selecting the trust certificate and clicking on
320
.
Administration Mode
Figure 11.40. Trust certificate detailed view
The following contents is displayed in the Details field:
Name: Trust certificate alias name. CN=Name, OU= Organizational Unit, O= Organization, L=City, ST= State/
Province, C=country, DC=Domain Components
Owner: Owner of the trust certificate.
Issuer: Issuer of the trust certificate.
Valid starting: Validity start date.
Valid through: Validity end date.
Type: Trust certificate format.
Issue Date: Issue date (import date) when the certificate was imported into the certificate memory.
MD5 fingerprint: The fingerprint in MD5 format.
SHA-1 fingerprint: The fingerprint in SHA format.
321
Administration Mode
Identification number: The trust certificate identification number.
The certificate chain is displayed hierarchically in the certification path field. The selected trust certificate is the
last one in the chain. Valid certificates are in green, invalid ones in red.
By clicking on
you leave the detailed view and return to the list view.
If a trust certificate is no longer needed, highlight it and click on
memory. Confirm one more time to delete the certificate.
to delete it from the certificate
11.7. Test baseline area
A test environment can be configured in the Test baseline area of the Administration mode. Here you can specify
if the test should be based on production data or on test baseline data.
Test baseline / data configuration
Figure 11.41. Data configuration view
THe Test baseline area specifies if production data or the data in a test baseline should be used. The desired
option should be selected here.
The path to production data cannot be changed. The path to the test baseline data can either be entered directly in
the text field or a file path can be selected using the Select button. If the path is invalid because the folder does
not exist, the text field will be marked with a red x.
Check for updates: If this is checked off, the system will check for a more current version of the data when a test
baseline is used. If yes, a prompt will ask if the new version should be downloaded.
322
Administration Mode
Use vehicle projects: If this is checked off, vehicle projects from the specified folder will be used.
Vehicle projects: An alternative folder that contains one or more vehicle projects that are not part of the production
or test baseline data can be selected here. This path can be entered directly or it can be browsed to using the Select
button.
If alternative vehicle projects are activated, the vehicle projects from the selected folder in the vehicle equipment
dialog or from configuration of the test test procedure are shown an can be loaded. All other data such as VRT,
VPT, XML reference tables, networking diagrams, service references and DIDB are taken from the specified data
source.
Saved changes can be reset to their default settings with the Reset button.
Changes that have not been saved yet can be restored to their default settings with the Discard
button.
Clicking the Save button saves the changes made.
If changes are made when a diagnostic session is active, they will go into effect once the diagnostic session ends
and a new diagnostic entrance begins. They go into effect immediately outside of a diagnostic session.
The changes made here are also shown when the version information dialog is opened.
Note:
Refer to the chapter "Info".
323
Chapter 12.
Functions
Additional
Program
This chapter describes the functions that are available through the various operating modes.
These additional program functions or standard functions are divided into four menus:
•
the Log menu
•
the Data menu,
•
the Extras menu and
•
the Help menu.
12.1. Log
The Protocol menu has three function areas:
•
General
•
Diagnostic log
•
Self diagnostic protocol
Figure 12.1. Screen button log
Here, actions can be performed in connection with the Guided Fault Finding diagnostic log and with the OBD log.
324
Additional Program Functions
12.1.1. General
This section applies likewise to the Guided Fault Finding diagnostic log as well as to the OBD log.
The current diagnostic log can be saved using this button. The Windows dialog for saving
files opens.
The sub-folder DiagnosticProtocols in the Offboard Diagnostic Information System Service directory is suggested as a save location for the Guided Fault Finding diagnostic log. SelfDiagnostic Logs is the suggested directly for the OBD log. The diagnostic log is saved in HTML format and can be opened in a web browser. This
button is active after performing a diagnosis.
The Guided Fault Finding diagnostic log is automatically saved in regular intervals. The interval can be set in
the Admin area.
Note:
See "Admin / Save Locations".
The current diagnostic log can be printed using this button after selecting the scope of the
protocol. The print menu opens and a printer can be selected. This button is active after performing a diagnosis.
There are three different formats for the saved log for sending, saving and printing the Guided Fault Finding
diagnostic log.
1. The long log format contains all data from a diagnostic session.
2. The short log format contains all session data from the vehicle-side with no GFF data.
3. The function test log format contains the GFF data from the diagnostic session.
The OBD log can also be selected if a OBD was performed.
Figure 12.2. Selecting the diagnostic log
325
Additional Program Functions
OK: Yhe selected log type is printed or saved.
Cancel: The log type selection is cancelled and the window closes.
12.1.2. Diagnostic log
The current diagnostic log can be sent to Volkswagen by clicking this button. An online
network connection and a login to the group systems are required. If there is currently no connection, the data are
stored temporarily and will be send the next time the group system is available after logging into the group systems.
The diagnostic log is also saved with the extension .b64 in the diagnostic log save location for sending externally.
If Offboard Diagnostic Information System Service was configured accordingly, then in some cases an additional translated diagnostic log will be stored. It has the same file name as the normal diagnostic log and the file
extension .b64_translated.
Note:
Refer to "Login to Group Systems".
Clicking this button opens a window in the folder with the saved diagnostic logs. A diagnostic
log that was already saved with in HTML or XML format or with the file extension .b64 can be copied. A b64 file
can be copied from another tester this way to an external storage device such as a USB stick for sending.
Note:
If, in addition to a .64-file, there is also a file with the same file name but the file extension .b64_translated exists,
then this should likewise be copied. It contains the same diagnostic log, except translated. If the diagnostic log
is going to be sent from a different tester, then the translated diagnostic log will also be sent because both files
are there.
Clicking this button opens a Windows file window for opening a *.b64 file. Using this function, a diagnostic log in b64 format can be loaded from an external storage device, such as a USB stick, and then
sent to Volkswagen if the group system connection is not available on the original tester. This button is available
immediately after starting the application.
If there is a .b64_translated file with the .b64 file, then it will also be sent. The user does not need to do anything.
326
Additional Program Functions
12.1.3. Self diagnostic protocol
The screen buttons for the OBD log are active only when an OBD is performed.
Clicking on these screen buttons generates a new OBD log. It is not necessary to generate a
new log at the beginning of a diagnostic session since this happens automatically for each diagnostic entry. New
OBD logs can be generated however, during the diagnostic session. Caution: When a new log is generated, the
log before it is not saved automatically.
Clicking on this screen button adds the information to the current log taken from the current
OBD view.
saves the current OBD log in XML or HTML using the Admin area under save locations/diagnostic log settings and shows it in the system standard browser.
Note:
See "Save locations area / diagnostic log".
This screen button is active only when the current view of the OBD generates data periodically. When it is selected, the data is written periodically into the current OBD log.
Note:
Since a large amount of data can be generated when adding periodically, this functionality is limited to 10000
values. The user receives a dialog when this limit is exceeded asking either to end the periodic update or to
continue in a new log. In both cases the existing log is saved beforehand.
Figure 12.3. Maximum number of values exceeded
OK: saves the existing OBD log. Depending on the selection, the period recording is ended or continued in a
new log.
327
Additional Program Functions
Ends the periodic recording of generated data. This screen button is active only when Periodic
adds was confirmed.
Note:
Refer to "OBD".
12.2. Data
There are three function areas in the Data menu:
•
Current view
•
Diagnostic session
•
Hotfix
328
Additional Program Functions
Figure 12.4. Data button
Notice:
After an Offboard Diagnostic Information System Service software or data update, diagnostic sessions from
a previous version cannot be loaded because the software and DIDB versions are different. To continue a paused
diagnostic session by loading the session data, the software and DIDB versions must match.
Note:
Refer to "System Environment" in the Administration chapter.
329
Additional Program Functions
12.2.1. Current view
Current view:
Clicking this button creates and prints a screenshot of the current view. The standard operating
system window opens to select the printer. If the view is empty, for example there is a tab with no content, that
button will be grayed out.
12.2.2. Diagnostic session
Diagnostic session:
Clicking this button can save the current diagnostic session in the sessions subfolder so it can
be continued later. This button is active after performing a diagnosis.
Note:
Refer to "Repair Interruption".
Clicking this button can load a previously-saved diagnostic session in Offboard Diagnostic
Information System Service. This button is only available directly after starting the application but before beginning a diagnosis.
Note:
Refer to "Continuing a Repair".
330
Additional Program Functions
12.2.2.1. Repair interruption
Diagnostic sessions can be paused and resumed again when there is a repair interruption. The menu with the
buttons is described in greater detail above.
Note:
Refer to "Data".
Notice:
The vehicle status, meaning the status of the control modules (ability to be addressed, identification data and
DTC memory entries) must not be changed between saving and loading the diagnostic session data.
This button pauses the diagnostic session. Offboard Diagnostic Information System Service then opens the Stop prompt.
Figure 12.5. Query when canceling a diagnostic session
Yes: the save location specified in the administration settings is suggested.
No: the diagnostic session is not saved.
Figure 12.6. Saving a diagnostic session
331
Additional Program Functions
Diagnostic session data has the file ending *.ses.
Save: the diagnostic session is saved.
Cancel: the diagnostic session is not saved.
After saving, Offboard Diagnostic Information System Service asks if a feedback should be sent.
Figure 12.7. Feedback after Saving a Diagnostic Session
Cancel: the support request is cancelled.
Send support request: the support request is sent.
The system then returns to the start location.
Note:
Refer to "Save Locations Area" in the Administration chapter.
Note:
In the standard settings, diagnostic sessions are saved on the tester so a diagnostic session can also be resumed
or paused during road test mode. If a network path is entered in the settings, data is stored temporarily during
mobile operation and is compared when there is a network connection. Storage settings can be changed in the
Admin mode.
Note:
Refer to "Save Locations Area" in the Administration chapter.
332
Additional Program Functions
12.2.2.2. Performing a repair
The continue a repair, the diagnostic session data can be resumed. The menu with the buttons is described in
greater detail above.
Note:
Refer to "Data".
More than one diagnostic session cannot be run at a time, so this button is grayed out if another session is already
running. Diagnostic sessions can only be continued if diagnostic entry was not performed.
When you click the Continue button, the Windows dialog for loading a file appears.
Figure 12.8. Loading a diagnostic session file
Select the desired diagnostic session file.
Open: the diagnostic session is loaded.
Cancel: the diagnostic session is not loaded.
Notice:
The vehicle status, meaning the status of the control modules (ability to be addressed, identification data and
DTC memory entries) must not be changed between saving and loading the diagnostic session data.
If the vehicle status changed, Offboard Diagnostic Information System Service gives an error message indicating the changed data.
333
Additional Program Functions
Figure 12.9. Error when loading a diagnostic session
In the example above, the VIN for the saved vehicle is different from the vehicle that is currently connected.
The login to the group systems is activated to load a diagnostic session.
Figure 12.10. Login when loading a diagnostic session
If the data from the group systems should be used when continuing a session, a login is necessary.
Transfer: the login data that was entered (global user ID and password) are transferred and you are logged into
the system.
Cancel: the login to the group systems is cancelled. Group system information is not available in the session that
loads.
Note:
Refer to "Data".
334
Additional Program Functions
12.2.3. Hotfix
Hotfix:
As long as no diagnostic session was started or loaded, clicking on this screen button makes
possible to download a Hotfix or a workshop patch on the local hard drive disc from a directory. A hot fix is
available to a dealer (or workshop) individually.
Typical hotfix data includes diagnostic data or GFF test programs that have been adapted specially for the dealer.
Hotfixes that are already active can be overwritten by newer ones.
A directory selection dialog opens after activating the Get screen button. The user selects a directory, that contains
the hot fix, notably the installation_index.xml file.
Figure 12.11. Selecting the hot fix directory
OK: Selects the directory.
Cancel: the hot fix is not loaded.
After the OK screen button is activated, Offboard Diagnostic Information System Service checks if the workshop patch is in the specified directory. It not, an error message is displayed:
335
Additional Program Functions
Figure 12.12. Error while loading the hot fix
OK: Closes the dialog and ends loading the patch.
If there is a hot fix available and in the correct format, it is copied into the application.
Figure 12.13. Copying the hot fix
It is installed then:
Figure 12.14. Installing the hot fix
If an error occurs, the user sees an error message:
Figure 12.15. Error while installing the hot fix
336
Additional Program Functions
If the hot fix was loaded and installed successfully, the use sees:
OK: Closes the dialog and ends loading the patch.
Figure 12.16. Hot fix installation successful
OK: Closes the dialog.
As soon as a hot fix is active, that is, before is was installed successfully, the Delete is active.
This makes it possible to delete an installed hot fix or a workshop data patch. A message appears after ending
the deletion process:
Figure 12.17. Hot fix deleted successfully
Note:
The hotfix update date is not saved.
This button allows you to load a new test baseline to Offboard Diagnostic Information
System Service from a source folder. It is only active during a diagnostic session.
If the button is clicked, a dialog opens where the source and target folders can be entered.
337
Additional Program Functions
Figure 12.18. Loading test baseline
Source folder: The Open button can be used here to select a new test baseline.
Target folder: You can select the location where the test baseline should be stored here. The default is the "test
baseline" folder in the application's installation directory.
Load: Proceeds with loading.
Cancel: Closes the dialog without loading a test baseline.
The user must confirm again that the test baseline should be loaded before it loads.
Figure 12.19. Confirming test baseline loading
Yes: The test baseline begins loading.
No: Cancels loading and closes the dialog.
Loading runs in the background. A symbol appears in the status bar during the loading process:
Figure 12.20. Loading in the background
338
Additional Program Functions
A progress dialog opens if you click on the symbol:
Figure 12.21. Loading the test baseline
Close: Closes the dialog and continues the loading process in the background.
Cancel: Cancels loading and closes the dialog. A window appears to confirm the process:
Figure 12.22. Cancellation by user when loading the test baseline
If an error occurs during loading, an error message such as this appears:
Figure 12.23. Error when loading the test baseline
OK: Closes the dialog. The loading of the test baseline is cancelled.
A note appears if the loading process ended successfully.
339
Additional Program Functions
Figure 12.24. Successful test baseline loading
OK: Closes the dialog.
The system will search for updates during diagnostic entrance if the test environment in the Admin area was
configured to this and if the test baseline was activated there.
Note:
Refer to the chapter "Test environment".
A dialog will tell the user if updates were found.
Figure 12.25. Updating the test baseline
Yes: Starts the update.
No: Closes the dialog without starting the update.
Diagnostic logs that are created are not sent if a test baseline was used. A message appears if the Send or Send
external buttons were used to start the sending process.
Figure 12.26. Sending a diagnostic log with test baseline
OK: Closes the dialog.
340
Additional Program Functions
12.3. Extras
The following functionalities are available in the default functions Extras menu:
Figure 12.27. Extras Menu Content
•
Search function
•
Diagnostic interface
•
Road test
•
Update
•
Connection test
341
Additional Program Functions
12.3.1. Search
The Search button opens the search function.
The search function can also be opened from the Test Overview using the magnifying glass symbol.
Note:
Refer to "Component Selection".
Clicking the button or magnifying glass symbol opens the search template, which is empty the first time it opens
in a diagnostic session. After that, it will show the results from the previous search each time it opens.
Figure 12.28. Search function form
Search terms: one or more search terms can be entered in this field. Separate multiple search terms with
commas.
Object types: the search can be restricted here to certain types such as test programs, documents, diagnostic
objects, general functions and Guided Functions. At least one object type must be selected.
Note:
Refer to "Working with GFF", "Documents", "DISS/TSB", "Test Plan and Special Functions" and "Self Diagnosis".
Search: this button is activated once a search term is entered and at least one object type is selected. After
activating, the search results are displayed under Search results.
342
Additional Program Functions
Figure 12.29. Search function results display
The results are sorted according to
Object type and
Location.
Go to: An entry must be marked to access a result or attach the object type to the test plan. This button is
activated after that. Clicking Go to opens the marked objects.
A Document is displayed in the document view.
A Guided Function is started in the process.
A Test Program is attached to the test plan.
With a Diagnostic object, an available test is attached to the test plan.
A special function is added to the special functions.
The following illustration shows the results of a search.
Figure 12.30. Search result example
343
Additional Program Functions
The user marked the test program "Connection to A/C control module" in the search results and clicked Go to.
Offboard Diagnostic Information System Service attached the affected test program to the test plan and switches
to the test plan view.
Notice:
The search function is only active after diagnostic entrance. If diagnostic entry does not follow, the button
or magnifying glass symbol is inactive
and it is not possible to search for object types.
Note:
If the search function is started from Component selection it can only search for the Diagnostic object object
type.
12.3.2. Diagnostic interface
It is possible to change the diagnostic hardware.
Notice:
Offboard Diagnostic Information System Service is prepared for using the . The following models can be used
by Offboard Diagnostic Information System Service with not restrictions :
•
Blue Streak Electronics Inc. - iflash Global Programmer
•
Dearborn Group - VSI-2534
•
Drew Technologies - CarDAQ-Plus
•
I+ME Actia GmbH - PassThru+ XS
The PassThru boxes listed are already set up in Offboard Diagnostic Information System as diagnostic interfaces.
To use, the box simply needs to be connected to the diagnostic tester via a USB connection and the corresponding
software package needs to be installed from the Offboard Diagnostic Information System Service - Installation
folder (sub-directory "drivers") .
Clicking diagnostic interface in the standard functions Extras menu will call up the dialog
for changing the diagnostic hardware.
344
Additional Program Functions
A dialog opens, in which the diagnostic interface currently being used is displayed:
Figure 12.31. Current diagnostic interface display
Change VCI: Opens a dialog, in which a different diagnostic interface can be selected.
VCI configurationn: This screen button is active only when a diagnostic interface, which can be configured, is
connected. When this is confirmed, a new window opens to configure the diagnostic interface.
Details: Displays the detail information for the connected diagnostic interface.
OK: Closes the dialog. If the diagnostic interface was changed before, this change remains.
To change the diagnostic interface, click Change VCI. Now the available diagnostic interfaces are displayed in a
table in another dialog window. The diagnostic interface currently being used is already selected.
Figure 12.32. Changing the diagnostic interface
Now, the old diagnostic hardware can be removed from the vehicle and the new one can be connected. The new
diagnostic interface can be selected in the table.
Select: Changes to the selected diagnostic interface. If the change was successful, the Current VCI dialog described above is displayed. The diagnostic interface change is closes when you close with Cancel.
Cancel: Closes the dialog without changing the diagnostic interface.
Clicking on the Details screen button in the Current VCI dialog displays the detail information for the diagnostic
interface currently selected. It is not possible to make any changes in this dialog.
345
Additional Program Functions
Figure 12.33. Detail information regarding the current diagnostic interface
OK: Closes the window and returns to the Current VCI dialog.
Cancel: The diagnostic hardware change is cancelled.
With configurable diagnostic interfaces, the VCI Configurationn is active in the Current VCI dialog. When this
is confirmed, a new window opens, in which the configuration of the web interface for the diagnostic interface
can be performed. Additional information regarding the configuration can be found in the documentation for each
diagnostic interface.
If there are problems when changing the diagnostic hardware, support must be switched on.
Note:
Refer to "Starting Diagnosis"
346
Additional Program Functions
12.3.3. Road test
A road test mode is integrated into Offboard Diagnostic Information System Service. This mobility mode must
be activated if a road test will be performed with the vehicle, resulting the tester not having a network connection.
Notice:
Mobile operation can only be started and ended when a network connection is available.
The Road test button has two functions that depend on the current situation and its appearance changes accordingly:
If the application is not in road test mode, this button starts the mode.
If the application is in road test mode, this button ends the mode.
This button must be clicked to start road test mode.
The following message appears:
Figure 12.34. Activating the road test mode
Activate road test mode: when this button is clicked, all necessary data is copied to the tester.
Cancel: road test mode is not activated.
After the copying process, a message appears indicating that the road test mode is now active.
Figure 12.35. Confirming the activated road test mode
Ok: clicking this button confirms the message.
347
Additional Program Functions
This symbol now appears in the information area and indicates that road test mode is active.
The data generated in mobile mode is stored temporarily on the tester. Sending feedback is also possible. Feedbacks
are saved temporarily until the road test mode ends and a connection to the network is reestablished. Then the
system sends them.
This button must be clicked to end road test mode.
Road test mode can be either cancelled or ended.
Figure 12.36. End road test mode
Cancel road test mode: if this button is clicked, mobile data is not compared with the workshop network. The
data generated in road test mode is deleted.
End road test mode clicking this button ends the road test mode and Offboard Diagnostic Information System
Service compares the mobile data with the data in the workshop network.
Cancel: the process of ending or cancelling road test mode is cancelled. The diagnostic session remains in road
test mode.
Figure 12.37. Confirming the cancelled road test mode
Ok: confirms the cancellation of road test mode.
Figure 12.38. Confirming the ended road test mode
Ok: confirms the ending of road test mode.
348
Additional Program Functions
Symbols then appear in the Offboard Diagnostic Information System Service information area that indicate the
status of the network connection and road test mode.
Network connection is available. Road test mode can be activated.
Network connection is interrupted. Road test mode cannot be activated. A network connection must be
established first.
Road test mode is activated.
Road test mode is activated but the network connection is interrupted.
Notice:
If the directory in which the global configuration is stored on the server is renamed or deleted during road test
mode, a message indicating this will NOT appear when ending road test mode. Offboard Diagnostic Information System Service will continue working with the local copy of the configuration. Those responsible for the
network will ensure Offboard Diagnostic Information System Service is configured correctly in the event of
any changes to the workshop infrastructure.
12.3.4. Update
The software and data update made by Offboard Diagnostic Information System Service can also be started
manually for an automatic periodic check.
This screen button starts checking the update.
Notice:
The manual update can be performed if Offboard Diagnostic Information System Service is not in a diagnostic
session. If a diagnostic session is active, the screen button will be deactivated.
The following message appears:
Figure 12.39. Notes when starting a manual update
349
Additional Program Functions
Yes: Clicking on this button checks for updates. If there are, the Offboard Diagnostic Information System
Service closes and starts again so that the update can be performed. If there are no updates, then there are no other
steps to be performed.
No: Checking for updates is stopped.
If the Yes screen button is pressed, the check is started and if necessary, updates are installed as described in the
"Update" chapter.
Note:
Refer to "Update".
12.3.5. Connection test
Offboard Diagnostic Information System Service offers the possibility to check the connection to the group
systems.
This screen button opens the dialog for configuring the connection test.
If a diagnostic entry was not performed, then a brand must first be selected. Based on this selecting, which group
system is available for the test.
Figure 12.40. Selecting a brand for the connection test
Select: applies the selected brand.
The following dialog appears:
350
Additional Program Functions
Figure 12.41. Connection test configuration
All group systems are listed in the table, for which a connection test can be performed. Place a check mark in
the left column to select a group system for the test. The test result is shown in the right column with a symbol.
The following is possible:
A connection test for this group system was still not performed.
The connection test was successful.
The connection test failed.
At the beginning, all entries have the symbol
.
Select all: Selects all group systems available for the connection test.
Deselect all: Remove the selection for all group systems.
No: Checking for updates is stopped.
Close: Closes the window.
Start: Performs the connection test for all control modules selected.
If a login to the group systems for the selected brands was still not performed, then dialog to login to the group
system appears, otherwise the connection test begins directly.
During the connection test, a dialog is displayed, showing the progress.
351
Additional Program Functions
Figure 12.42. Connection test is being performed
Cancel: Cancels the test.
After the connection to all the group systems selected is checked, the dialog closes automatically and the connection test dialog is displayed again. The test result is shown in the right column with a symbol.
12.4. Help
The Help menu contains the following function areas that provide the user with assistance if there are problems:
•
Online help
•
Support...
Figure 12.43. Help menu
12.4.1. Online help
Online help:
clicking this button opens Online Help in a separate window, which display help text that
matches the context of the application.
Online Help can be accesses at any time when using Offboard Diagnostic Information System Service.
Example: if you are in the Test plan tab while performing Guided Fault Finding and click the Help symbol,
Online Help will open the Guided Fault Finding chapter.
352
Additional Program Functions
Figure 12.44. Context-Based Online Help
The following information provides a more detailed explanation of the Online Help window.
353
Additional Program Functions
Figure 12.45. The Online Help window
in the left area of Online Help
can be used to find the corresponding chapter based on the table of contents.
There are navigation symbols below the window for navigating in the table of contents and the search results
.
From left to right, the navigation symbols can be used to open the complete table of contents, list all search
results after a search, display the current link and set a bookmark.
In the right area of Online Help,
the desired information is displayed after selecting a chapter. You can navigate
through it using the navigation bar
.
Using the search function,
you can also search for specific terms within Online Help. After entering the
search term, click Go to search.
In the right window with the help texts, you can navigate using links and the navigation bar.
354
Additional Program Functions
Figure 12.46. Navigation in Online Help
You can navigate with links (show in blue, underlined font) within the help texts displayed in the right area. The
links are always located above and below a chapter or subchapter. There are also cross references in the text that
link directly to the specified chapters.
Back: this link takes you to the previous page.
Next: this link takes you to the next page.
Text reference: this link takes you to the corresponding chapter.
The navigation bar (item 4 in the illustration of the Online Help window above) can also be used for navigating
through the Help section.
Figure 12.47. Online Help Navigation Bar
In order from left to right in the navigation bar displayed above, you can navigated backward and forward, open
the Online Help home page, display the table of contents, set a bookmark, print the help text and maximize
the Help window.
355
Additional Program Functions
12.4.2. Support
Support:
There are several ways to send a support request or feedback or to store it locally from Offboard Diagnostic
Information System Service.
In the standard functions that are always visible, a support request can be sent or stored at any time using the
Support button.
The prompt asking if a feedback should be sent is part of the process for ending a diagnostic or flash session.
Note:
Refer to "Ending Diagnosis".
Refer to "Flashing Mode".
When the application has ended, it is also possible to send or save a feedback.
This button opens the Send support request window.
Figure 12.48. Save support request
This button can be used to send a screenshot of the error message or problem with the
support request. Clicking the Attach current view button attaches the current view from Offboard Diagnostic
Information System Service to the text field as a graphic.
356
Additional Program Functions
Clicking the Cancel button cancels the support inquiry and does not send it. The window closes. A
prompt must be confirmed to cancel the support request.
Yes: the support request is cancelled and it ends.
No: the support request is not cancelled.
Feedback cannot be sent if required fields in the Subject and Hotline areas are empty or contain
invalid values. Missing or invalid values are highlighted in red.
In this case, the Save... button will be active. This can be used to save a feedback with the diagnostic session,
diagnostic log, screenshots and free text locally. When the button is clicked, the dialogs dialog for selecting a save
location appears. The feedback file with the attachments is saved there as a zip file.
Once all required fields are filled with valid values, the Save... button is replaced with Send.
Figure 12.49. Send support inquiry
This button sends the support request.
357
Additional Program Functions
Online Help for managing feedback is available through this button.
The Feedback sender information is located in the top left of the support window.
Figure 12.50. Information about feedback sender
The
First name,
Last name,
E-mail address and
Telephone number
are entered here.
If the information about the feedback sender was entered in Administration under the Support area (refer to
the reference below), this information will already be filled in. The data can be overwritten in the Send support
request dialog. If the data that overwrites the default information should be used for the next support request, it
can be changed in the Administration section under Support area.
In addition to the sender's information, the brand of the diagnostic data being used must be selected in the Manufacturer field, even if no diagnostic session is currently running. Otherwise, the field is already prefilled according
to the vehicle brand.
Note:
Refer to "Support Area" in the Administration chapter.
The error classification section assigns the error to an area in the application.
Figure 12.51. Error classification feedback
Here you specify if the error involves hardware, software, a content error or a translation error or if the error cannot
be assigned to any of these errors. Only one selection is possible.
The priority indicates how urgently the error must be corrected.
358
Additional Program Functions
Figure 12.52. Error priority feedback
For information is activated when there is feedback in the form of comments and suggestions. That is the default
setting.
Limited order editing functions possible must be activated if there are inconsistencies and error messages that
interfere with the procedure.
Order editing not possible is activated when this error prevents work with Offboard Diagnostic Information
System Service
The Attach current diagnostic session checkbox must be selected to add the current diagnostic session.
Figure 12.53. Additional attachments
Attach current diagnostic session: The current diagnostic session contains information makes is easier for Offboard Diagnostic Information System Service development team to process the user feedback. The current diagnostic log is automatically attached to every feedback.
Attach current OBD log: If a OBD log was generated, then it can be added here to the feedback. This option
is deactivated if there is no OBD log.
Notice:
The checkbox Attach current diagnostic session must always be activated if contacting support regarding problems with GFF performance.
In the case of errors, a screenshot must be sent to ensure the error is evaluated and corrected as quickly as possible.
If the mail server login is activated in the support/e-mail outbox server administration, the dialog to log into the
mail server appears after clicking the Send button.
359
Additional Program Functions
Figure 12.54. Logging into the mail server for feedback
Transfer: the application logs into the mail server using the user name and password that was entered and sends
the feedback.
Cancel: the feedback is not cancelled.
If incorrect access data, user name or password are entered, the Error message ODS9106E appears with a notification about the incorrect access data.
Figure 12.55. Incorrect login to mail server
Transfer: the application logs into the mail server using the user name and password that was entered and sends
the feedback.
Cancel: the feedback is not cancelled.
360
Additional Program Functions
Note:
Refer to "E-mail Outbox Server Details" in the Administration chapter.
Notice:
If there is currently no online connection, the support inquiry is saved temporarily in the system and will be sent
the next time an online connection is available.
Figure 12.56. Feedback message with an offline connection
Ok: The message is confirmed and closed.
361
Additional Program Functions
12.5. Info
After starting Offboard Diagnostic Information System Service, a window with general warnings and notes
appears first. The following illustration show the window in the various scroll bar positions.
362
Additional Program Functions
Figure 12.57. Windows with warnings/notes (part 1)
363
Additional Program Functions
Figure 12.58. Windows with warnings/notes (part 2)
364
Additional Program Functions
Figure 12.59. Windows with warnings/notes (part 3)
Ok: The window will close.
These warnings and notes can be opened at any time in the Information area.
The Information area contains various information functions.
365
Additional Program Functions
Figure 12.60. Information Area
•
New:
this button opens the release notes with information about new functions that were not in the previous version
of Offboard Diagnostic Information System Service and about errors that were corrected.
The window displays automatically whenever a new installation of Offboard Diagnostic Information System
Service is started.
•
Versions:
This button opens the Version information window. It contains information about the versions of Offboard
Diagnostic Information System System that are installed, the diagnostic data, the MCD server, the PDU API,
the ECP and the ODX projects.
•
Warning:
this button opens the warnings/notes window with warnings and notes in the Warning category.
•
Caution:
this button opens the warnings/notes window with warnings and notes in the Caution category.
•
Note:
this button opens the warnings/notes window with warnings and notes in the Note category.
The warning, caution and note descriptions can be accessed individually using the Information menu.
366
Chapter 13. Error Messages
When using Offboard Diagnostic Information System Service, error messages may be generated for different
reasons. Error messages contain information that are important for classification and the rest of the process.
Figure 13.1. Error message explanations
Error ID: the ID that is assigned to the error.
Topology name: the name of the area in the application where the error occurred.
Error description: the description of the error behavior.
Ok: The error message closes.
You can search for the error message in the "Error ID" table using the error ID. The right Notes column will
describe what to do next.
Notice:
The most frequent error messages occur when there are problems with the connection to the vehicle and to the
network. Checking the connection and restarting the system is recommended.
367
Error Messages
13.1. Error IDs
ID
Displayed Error
Note
without ID
No vehicle data was found
This message can appear on the Orders, Vehicles
and PR Numbers tabs.
Check the network connection and contact Support.
without ID
The page cannot be displayed.
The current network status is displayed in the Info area of the user interface. If the network status
is offline, the TPI, Campaign, History, Wiring
Diagrams and Manuals tabs cannot be displayed.
Check the network connection and contact Support.
without ID
There is no network connection available.
If a tab was activated when there was a network
connection but it then disconnects, the following
error message will appear:
Reestablish the network connection or contact
Support.
ODS0001E
The sensor is not connected to the logical con- Please contact Support.
nection.
ODS0002E
Executing in current condition is not permitted. Please contact Support.
ODS0003E
Object is in poor condition.
ODS0004E
The configuration does not match the connected Please contact Support.
device.
ODS0005E
An error occurred in the oscilloscope display Please contact Support.
module.
ODS0006E
A trigger channel was not established for the Please contact Support.
triggered measurement.
ODS0007E
The GDI versions of GDI components do not Please contact Support.
match.
ODS0008E
A GDI error has occurred.
ODS0009E
An error occurred in the GDI coordinator: ... (er- Please contact Support.
ror code: ...
ODS0010E
An error occurred in the GDI driver: ... (error Please contact Support.
code: ...
ODS0011E
A conflict with the DCD has occurred.
ODS0012E
A failure occurred when installing the device Please contact Support.
driver.
ODS0013E
The measuring device is not established in the Please contact Support.
GDI driver.
ODS0014E
An error occurred when parsing the specified Please contact Support.
curve ....
Please contact Support.
Please contact Support.
Please contact Support.
368
Error Messages
ID
Displayed Error
Note
ODS0501E
No knowledge base is available for the selected Please check if there are updates to the software
model.
or data.
The "Flashing" mode cannot be performed for If the problem persists, please contact support
this model.
immediately.
ODS0502E
The existing software installation is incomplete. Please check if there are updates to the software
or data.
The "Flashing" mode cannot be performed with
the existing software.
If the problem persists, please contact support
immediately.
ODS0503E
The current brand ... is not supported by the Please check if there are updates to the software
"Flashing" operating mode at this time.
or data.
The "Flashing" mode cannot be performed for If the problem persists, please contact support
this brand.
immediately.
ODS0504E
There are inconsistencies within the diagnostic Please check if there are updates to the software
data for the current brand ... .
or data.
The "Flashing" mode cannot be performed for If the problem persists, please contact support
this brand.
immediately.
ODS0505E
There are ambiguities within the diagnostic data Please check if there are updates to the software
for the current brand ... .
or data.
The "Flashing" mode cannot be performed for If the problem persists, please contact support
this brand.
immediately.
ODS1001E
Not available - timeout after ... seconds.
Please contact Support.
ODS1002E
The session for account ... has expired.
Please restart the program.
If the problem persists, please contact support
immediately.
ODS1003E
The connection to VehicleBaseServiceV15 Incorrect connection and server data was entered
could not be established.
in the administration area.
Please contact Support.
ODS1004E
The connection to ... ended.
Please try again. If it is still not possible to login,
contact Support.
ODS1005E
A transmission error ... occurred when connect- Please try again or contact Support.
ing to ....
The connection was interrupted.
ODS1006E
A connection could not be established with the The address is not responding at this time.
URI/URL.
Please try again later or contact Support.
ODS1007E
Negative response from the server. The error ID Please contact Support.
is ...
ODS1008E
Negative response from the server:
ODS1501E
The version of the selected session ... is not com- Please contact Support.
patible with the current program version .... . The
session cannot be loaded.
ODS1502E
The type of the selected session ... is not com- Please contact Support.
patible with the current product .... The session
cannot be loaded.
Please contact Support.
369
Error Messages
ID
Displayed Error
Note
ODS1503E
The type of selected session cannot be identified. Please contact Support.
The session cannot be loaded.
ODS2001E
The password for account ... is invalid.
Please contact Support.
ODS2002E
The password for account ... has expired.
Please contact Support.
ODS2003E
No authentication available.
Please contact Support.
ODS2004E
The account ... is unknown.
Please contact Support.
ODS2005E
Authentication is required to access ....
Please contact Support.
ODS2006E
The hardware with ID ... is marked as locked. A login was attempted with a tester whose hardPlease contact support.
ware ID was locked on the server side.
Please contact Support.
ODS2007E
Your flat rate has expired. Please contact sup- Please obtain a new flat rate if you are an indeport.
pendent market operator.
Please contact Support if you are an authorized
dealer.
ODS2008E
The maximum number of simultaneous users Please log in again later.
sessions for your flat rate has been reached. A
login is only available once a current user session ends.
ODS2500E
The group system has reported an error: ...
ODS2501F
No MCD system was found. Please check the Please contact Support.
MCD system installation.
ODS2502E
No data available.
Please contact Support.
Possible causes could be:
Missing or faulty vehicle project
the control module is not designed for this function
Please contact Support.
ODS2503E
The VIN could not be read or detected.
Make sure there is a connection to the vehicle
and the ignition is switched on.
ODS2504F
No MCD/DTS system was found.
Please contact Support.
ODS2506E
Printing could not be completed.
The printer could not be accessed
The user cancelled the print job.
Please check the printer settings or contact the
system administrator.
ODS2507E
The print layout for the graphic could not be gen- Please contact Support.
erated.
370
Error Messages
ID
Displayed Error
Note
ODS2508F
Important MCD server libraries were not found. Possible causes are:
1. The MCD server is not installed. Please install
the current MCD server to correct this.
2. The system path does not contain the MCD
sever working directory.
3. The MCD server working director cannot be
accessed.
Please contact Support.
ODS2509F
There are differences between the installed and Please install the current MCD server to correct
expected version of necessary Softing libraries. this.
Please contact Support.
ODS2510F
The ECF framework for access to the MCD sys- Please install the current ECF version to correct
tem could not be found.
this.
Please contact Support.
ODS2511F
The MCD system could not be found.
There are several possible causes.
1. Another application that uses the MCD server
is active. Close those applications and restart the
application.
2. Another application that uses the MCD server
cannot be closed. Restart the computer and try
again.
Please contact Support.
ODS2512F
The system is powering down. All activities in Please check if Offboard Diagnostic Informaprogress will be ended.
tion System Service functions correctly after
starting. If it does not function correctly, contact
Support.
ODS2513E
The MCD system diagnostic interface is not con- Check the configuration of your diagnostic hardfigured clearly.
ware in the PDU API and modify if necessary.
ODS2514E
Error when accessing the Logical Link Monitor Please contact Support.
for the MCD system.
ODS2515E
Error when opening the MCD project.
Please contact Support.
ODS3001E
The file ... was not found.
Make sure the correct path was entered or contact Support.
ODS3002E
Account ... does not have read authorization for You do not have the necessary authorization.
the file ...
Please contact Support.
ODS3003E
Account ... does not have write authorization for You do not have the necessary authorization.
the file ...
Please contact Support.
ODS3004E
No space to write the file ...
The data storage location is full. Please contact
your system administrator or Support.
ODS3005E
The file folder ... was not found.
Make sure the correct path was entered or contact Support.
ODS3006E
Incorrect file name format for file ... The for- Please contact Support.
mat ... was expected.
371
Error Messages
ID
Displayed Error
Note
ODS3007E
The file ... in the folder ... cannot be written.
Please contact Support.
ODS3008E
The file ... in the folder ... cannot be opened or Please contact Support.
read.
ODS3009E
The file ... cannot be copied to ....
ODS3010E
Filter file for HexService is not available or can- Please contact Support.
not be read.
Please contact Support.
The HexService function cannot be performed.
ODS3011E
An error occurred when displaying the results of Please contact Support.
the equipment level check.
ODS3012E
An error occurred when generating the HTML Please contact Support.
results log.
ODS3013E
An error occurred during the Html transforma- Please contact Support.
tion for the current vehicle project.
ODS3014E
An error occurred when unpacking the file.
ODS3015E
The selected data set does not contain a control Please contact Support.
file.
ODS3501E
Connection data to group systems incorrect or Please contact Support.
not available. Please contact support.
ODS4001E
The data structure ... could not be created or con- Please contact Support.
verted. Please contact support.
ODS4002E
The software library ... was not found.
Please contact Support.
ODS4003E
The software library ... could not be opened.
Please contact Support.
ODS4004E
The parameters received for the request from ... Please contact Support.
are incorrect.
ODS4005F
Incorrect Java installation.
Please contact Support.
ODS4006E
The service module ... is not available.
Please contact Support.
ODS4007E
The service ... could not be configured.
Please contact Support.
ODS4008E
The session for vehicle ... could not be reestab- Please check the connection to the vehicle or
lished.
contact Support.
ODS4009E
An internal system error has occurred. The sys- Please restart the system. If the error is not cortem has become unstable. Please send a feed- rected, contact Support.
back and contact support. End the system and
restart.
ODS4010E
The file structure ... contains content errors.
Please contact Support.
ODS4011E
The system does not support the code ....
Please contact Support.
ODS4012E
No session data available for saving.
Please contact Support.
ODS4013E
Session data cannot be reconstructed.
Please contact Support.
ODS4014E
Session data cannot be saved.
Please contact Support.
ODS4015E
An error occurred when entering one of the pa- Please contact Support.
rameters.
The entry cannot be converted into the parameter
type.
372
Please contact Support.
Error Messages
ID
Displayed Error
Note
ODS4016E
An error occurred when entering one of the pa- Please contact Support.
rameters.
The parameter type is not supported.
ODS4501E
The road test mode could not be activated.
Please contact Support.
ODS4502E
The license file cannot be opened or read. Road Please contact Support.
test mode was not activated.
ODS4503E
The license file could not be copied. Road test Please contact Support.
mode was not activated.
ODS4504E
The road test mode could not be deactivated.
Please contact Support.
ODS5001E
Test program/step ... cannot be loaded.
Please contact Support.
ODS5002E
Measurement connection is not available.
Please contact Support.
ODS5003E
A fatal internal test program error has occurred. Please contact Support.
Test cancelled. Error type: ...
Details: ...
ODS5004E
Internal test program error. A user action was at- Please perform the test again or contact Support.
tempted that is not permitted within a test step.
Test cancelled.
ODS5005E
The document ... could not be loaded.
ODS5006E
The knowledge bank for the vehicle could not be Please contact Support.
determined. Guided Fault Finding is not possible
for this vehicle. Details: ...
ODS5007E
A version problem was detected with the ... test. Please contact Support.
ODS5008E
Decompression of the ... test program failed due Please contact Support.
to missing or invalid compression. The test program could not load.
ODS5009E
Decryption of the ... test program failed due to Please contact Support.
missing or invalid encryption. The test program
could not load.
ODS5010E
Signature validation of the ... test program failed Please contact Support.
due to a missing or manipulated signature. The
test program could not load.
ODS5501E
Control module ... could not be found.
Please contact Support.
ODS5502E
Connection ... could not be opened.
Please contact Support.
ODS5503E
Connection ... could not be established.
Please contact Support.
ODS5504E
Unexpected result of control module communi- Please contact Support.
cation, method ...
ODS5505E
Control module communication could not be Please contact Support.
performed, method ...
ODS5506E
Error ... during control module communication, Please contact Support.
job ..., control module ..., ECF error text: ...
ODS5507F
Communication descriptive file ... could not be Please contact Support.
found.
ODS5508F
Error when reading the communication descrip- Please contact Support.
tive file.
ODS5509F
Content of the communication descriptive file Please contact Support.
invalid.
Please contact Support.
373
Error Messages
ID
Displayed Error
Note
ODS5510E
Communication job ... for control module ... Please contact Support.
could not be found in the descriptive file.
ODS5511E
Faulty description in method ... ... in the descrip- Please contact Support.
tive file.
ODS5512E
Error when compiling parameters for class ...
ODS5513E
Communication job ... for connection ... could Please contact Support.
not be created.
ODS5514E
Fault job description for ... in descriptive file.
ODS5515E
Error when providing results of control module Please contact Support.
communication.
ODS5519E
Internal error in test program: Method ... for Please contact Support.
job ... not found.
ODS5551E
Connection name for control module ... could Please contact Support.
not be found.
ODS5552E
Communication job ... could not be established. Please contact Support.
ODS5553E
Request parameters for communication job ... Please contact Support.
could not be established.
ODS5554E
No valid value could be determined for the re- Please contact Support.
quest parameter ... in the communication job ....
ODS5555E
Unknown request parameter ... for communica- Please contact Support.
tion job ... .
ODS5556E
The value ... for the request parameter ... could Please contact Support.
not be changed to type ...
ODS5557E
The value of type ... for the request parameter ... Please contact Support.
cannot be changed to type ...
ODS5558E
The value ... for the request parameter ... could Please contact Support.
not be entered.
ODS5559E
Control module communication could not be Please contact Support.
performed, communication job ... .
ODS5560E
Error ... during control module communication, Please contact Support.
job ..., control module connection ... .
ODS5570E
Measure value table ... was not found.
Please contact Support.
ODS5571E
Entry ... in measured value table ... not found.
Please contact Support.
ODS5572E
Control module ... from measured value table ... Please contact Support.
not found.
ODS5573E
No valid entries found in measured value ta- Please contact Support.
ble ... .
ODS6003F
The brand ... for the installed diagnostic data is Please contact Support.
different from the brands in the certificate: ...
ODS6004F
The installed software version ... is different Please contact Support.
from the version in the certificate: ...
ODS6005F
The hardware key in the certificate ... does not Please contact Support.
match the hardware key for hardware ....
ODS6007F
The certificate ... has already expired.
Please contact Support.
ODS6008F
The certificate becomes valid on ... .
Please contact Support.
374
Please contact Support.
Please contact Support.
Error Messages
ID
Displayed Error
Note
ODS6009F
A valid contract status could not be established. An error occurred when determine the dealer's
The diagnostic session is ending.
contract status from the license.
Please contact Support.
ODS6010E
You do not have authorization for the selected An attempt was made to load a diagnostic sesbrand. Cancelling the diagnostic session load- sion with an unlicensed brand.
ing.
Please contact Support.
ODS6011E
The contract status of the diagnostic session does An attempt was made to load a diagnostic sesnot match your contract status. Cancelling the sion when the stored contract status did not
diagnostic session loading.
match the current contract status for the brand
in use.
Please contact Support.
ODS6012F
Brand-based information could not be deter- Please contact Support.
mined because no current brand is available.
ODS6013F
There is no information in the license for the ... Please contact Support.
brand.
ODS6101E
Creation or access to certificate memory failed. Please contact Support.
ODS6102E
Import of the certificate file failed.
Please contact Support.
The file format is not supported.
ODS6103E
Import of the certificate file failed.
Please contact Support.
The certificate file does not contain only X.509
certificates.
ODS6104E
Import of the certificate file failed.
Please contact Support.
The private key could not be determined. Please
check the password.
ODS6105E
Import of the certificate file failed.
Please contact Support.
The validity period for the certificate does not
include the current date.
ODS6106E
Import of the certificate file failed.
Please contact Support.
The certificate chain to be imported is not valid.
ODS6107E
Import of the certificate file failed.
Please contact Support.
The certificate hardware ID does not match the
hardware ID in the current ODIS license.
ODS6108E
Import of the certificate file failed.
Please contact Support.
The certificate could not be added to the certificate memory.
ODS6109E
Deleting the certificate failed.
Please contact Support.
The certificate could not be deleted from the certificate memory.
ODS6110E
Access to the certificate memory for client cer- Please contact Support.
tificates failed due to a different hardware ID.
The certificate memory will be created again.
ODS6301E
The index file or test baseline was not found.
375
Please use a folder that contains a valid test baseline or contact Support.
Error Messages
ID
Displayed Error
Note
ODS6302E
Incorrect test baseline index file structure.
Please use a folder that contains a valid test baseline or contact Support.
ODS6303E
The test baseline contians ... . This is missing in Please use a test baseline that matches the curthe production DIDB.
rent DIDB or contact Support.
ODS6304E
The ... in the test baseline is version ... . This does Please use a test baseline that matches the curnot match the production DIDB version ... . .
rent DIDB or contact Support.
ODS6305E
The test baseline is incomplete. The following Please use a folder that contains a valid test basefile is missing in the storage location ... .
line or contact Support.
ODS6310E
Copying the test baseline failed. The file ... was Please use a folder that contains a valid test basenot found.
line or contact Support.
ODS6311E
Copying the test baseline failed. File ... could not Please check if there is enough storage space or
be copied.
if the file is currently in use or contact Support.
ODS6312E
Copying the test baseline failed. Directory ... Please check if there is enough storage space or
could not be created.
if the directory is currently in use or contact Support.
ODS6313E
Copying the test baseline failed. Directory ... Please check if the directory is currently in use
could not be deleted.
or contact Support.
ODS6314E
Copying the test baseline failed. The directory ... Please select another directory or contact Supalready exists.
port.
ODS6315E
Copying the test baseline failed. The file could Please check if there is enough storage space or
not be unpacked.
contact Support.
ODS6316E
Copying the test baseline failed. File ... could not Please check if the file is currently in use or conbe deleted.
tact Support.
ODS6501E
The database ... required for the application was Please end the application and check the instalnot found.
lation.
Please contact Support.
ODS6502E
Error when determining the metadata for the da- Please contact Support.
ta adapter ....
ODS6503E
The database ... could not be opened. Please end If the error persists, please contact Support.
the application and restart.
ODS6504E
No data adapter was found so no database is Correct or update the installation.
available. Diagnosis is not possible.
Please contact Support.
ODS6801E
The system name ... is ambiguous. The con- Please contact Support.
straints must be defined concretely.
ODS6901E
The base version is being used due to missing Please update the DIDB.
diagnostic data: Address: ... - System name ... .
ODS7001E
The database ... cannot be opened.
Please contact Support.
ODS7002E
The database ... cannot be closed.
Please contact Support.
ODS7003E
The database ... cannot be read.
Please contact Support.
ODS7004E
The database ... cannot be written.
Please contact Support.
ODS7005E
The database structure is faulty.
Please contact Support.
ODS7006E
Internal database access error - no primary key Please contact Support.
defined for table ....
ODS7007E
An increment for updating could not be deter- Please contact Support.
mined. The directory entered may not be specified correctly.
376
Error Messages
ID
Displayed Error
Note
ODS7008E
The version comparison has detected an incom- Please contact Support.
patibility. The specified test baseline does not
match the current environment.
ODS7501F
The Diagnostic Information Database (DIDB) is Please contact Support.
not available.
ODS7502E
Diagnostic Information Database (DIDB) in- Please contact Support.
quiry failed.
ODS7503E
The diagnostic database update failed. Diag- Please contact Support.
nosis performed with the old diagnostic data.
Please contact support.
ODS8001E
Communication with the vehicle cancelled.
ODS8002E
Communication to the control module with con- Please contact Support.
trol address ... was faulty.
ODS8003E
The operation on the control module with con- Please contact Support.
trol address ... was faulty.
Please check the connection to the vehicle or
contact Support.
Error message: ...
ODS8004E
Communication to the vehicle could not be es- Please check the connection to the vehicle or
tablished.
contact Support.
ODS8005E
The following error occurred during communi- Please contact Support.
cation with the MCD system: ...
ODS8006F
Diagnostic hardware not found. Make sure the Please check the connection to the vehicle and
hardware is connected correctly.
the diagnostic hardware or contact Support.
ODS8007E
The following error occurred during communi- Please contact Support.
cation with the MCD system:
Error code: ...
Error code description: ...
ODS8008E
The following error occurred during communi- Please contact Support.
cation with the vehicle:
Error code: ...
Error code description: ...
ODS8009E
The DTC memory could not be read during com- Please contact Support.
munication with the control module ...
Error description: ...
ODS8010E
The control module cancelled the operation. Please contact Support.
Possible causes are:
incorrect or missing login
other
ODS8011E
The control module with control address ... is not Please contact Support.
installed or is not responding.
377
Error Messages
ID
Displayed Error
Note
ODS8012E
An error occurred during communication with Please contact Support.
the vehicle:
The control module response contains implausible data.
ODS8013E
An error occurred when filtering/checking the Please contact Support.
flash session. A possible cause could be incompatibility between ODX data and flash data.
ODS8014E
The diagnostic project ...is not available. Please Please contact Support.
check the installation of your software.
ODS8015E
Communication to the vehicle could not be reset. Please contact Support.
Possible cause: there may be active diagnosis
jobs.
ODS8016E
An error occurred during communication with Please contact Support.
the vehicle:
Check if the ignition is switched on.
ODS8017F
An error occurred when initializing/deinitializ- Please contact Support.
ing the hardware on: ...: ...
with the following manufacturer error description: ...
ODS8018E
An error occurred during communication with Please contact Support.
the vehicle:
The control module response contains implausible data.
ODS8019E
An error occurred during communication with Please contact Support.
the vehicle:
The control module did not accept the code.
ODS8020E
An error occurred during communication with Please contact Support.
the vehicle:
The operation on the control module was faulty.
ODS8021E
An error occurred during communication with Please contact Support.
the vehicle:
The control module ended the operation.
ODS8022E
An error occurred during communication with Please contact Support.
the vehicle:
The entry is outside the valid value range.
378
Error Messages
ID
Displayed Error
Note
ODS8023E
An error occurred when entering or interpreting Please contact Support.
data. Possible causes are:
One of the entries is outside the valid value
range.
The control module is delivering implausible data.
The MCD system is reporting the following error:
Error code: ...
Error code description: ...
ODS8024E
An error occurred during communication with Please contact Support.
the MCD system:
The MCD job ... did not deliver any results after
completion.
ODS8025E
Access to the communication parameters for Please contact Support.
control module ... is not possible before the connection is established.
ODS8026E
The communication to the vehicle was interrupt- Please contact Support.
ed.
Possible causes: vehicle is not connected or the
battery is not connected.
Error code: ...
Error code description: ...
Note: ...
ODS8027E
The connection could not be made to control Please contact Support.
module ... - ... due to existing communication orders.
You can attempt to connect again once communication with this control module ends.
ODS8028E
Communication protocol ... is not supported.
Please contact Support.
ODS8029E
No Gateway is available.
Please contact Support.
ODS8030E
No Bus master is available.
Please contact Support.
ODS8031E
There is an error in the available diagnostic data. Please contact Support.
Diagnostic entrance cannot be performed.
ODS8032E
The selected mode cannot be used.
Please contact Support.
There are no other modes available to continue
diagnostic entrance.
ODS8033E
The selected mode cannot be used.
Please contact Support.
Diagnostic entrance must continue with a different mode.
379
Error Messages
ID
Displayed Error
Note
ODS8034E
There is no information available for the inter- Please contact Support.
nally identified vehicles.
Diagnostic entrance cancelled.
ODS8035E
Communication to the control module with con- Please contact Support.
trol address ... was faulty.
The attempt to connect is being blocked by another control module.
ODS8036E
No suitable OBD data are available in the vehi- Please contact Support.
cle project.
ODS8037E
The vehicle is not responding to OBD functions. Please contact Support.
ODS9001E
The software and database content is incorrect. Please contact Support.
ODS9002E
An error occurred when downloading the soft- Please contact Support.
ware and database.
ODS9003E
An error occurred when uploading the software Please contact Support.
and database.
ODS9004E
A connection to the MirrorServer2 cannot be es- Please contact Support.
tablished.
ODS9005E
There is not enough memory space for the up- Please contact Support.
date. ... KB are needed. Only ... KB are available.
ODS9006E
The update requires Administrator rights. Please Please contact Support.
contact the Administrator and then perform the
update.
ODS9007E
The update has failed or was cancelled.
ODS9008E
Updates were encountered that are not compati- Reinstall the current version Offboard Diagble with the version installed. Please reinstall us- nostic Information System Service or contact
ing the updated version.
Support.
ODS9009W
The current update could not be downloaded Make sure there is a network connection or conwithin the last X days. Make sure the diagnostic tact Support.
tester is connected to the Internet or to the CPN
and the update server is configured correctly.
ODS9010E
Insufficient disk space to download. X kB is Select a different directory on a different hard
needed, but only Y kB is available. Please select drive disc or partition or clean the hard drive disc
a different to directory download.
to create more disk space.
ODS9011E
The update is not complete. All of the required Please contact Support.
updates are not available. Please contact support.
ODS9012E
A connection to the MirrorServer2 cannot be Make sure there is a network connection and that
established. An error occurred when reading the network settings are configured correctly, or
the local update configuration. Please check the contact Support.
MirrorServer2 settings.
ODS9013E
The update contains an error in the file structure. Please contact Support.
Please contact support.
ODS9014E
A failure occurred when installing the update. Please try downloading and installing the update
Please try again.
again or contact Support.
ODS9015E
A connection to the MirrorServer2 cannot be es- Make sure there is a network connection and that
tablished. An error occurred when reading the the network settings are configured correctly, or
removed update configuration. Please contact contact Support.
support.
380
Please contact Support.
Error Messages
ID
Displayed Error
Note
ODS9101E
The local computer name could not be identi- Please contact Support.
fied.
ODS9102E
The configured mail server ... is unknown.
Please contact the mail server administrator or
your provider.
ODS9103E
No mail server specification configured.
Please add the specification or contact Support.
ODS9104E
E-mails failed to send.
Make sure there is a network connection or contact Support.
The original error message text is: ...
ODS9105E
Error when generating e-mail.
Please contact the mail server administrator or
your provider.
Invalid sender e-mail address ... found.
ODS9106E
Message to the mail server ... failed.
Please check the user name and/or password.
Please correct the user name or password or
contact the mail server administrator or your
provider.
ODS9201E
Dealer portal not available.
Please try again later or contact Support.
ODS9202E
Procedures could not be loaded.
Please try again later or contact Support.
ODS9203E
Creating test plan without customer code.
Please try again later or contact Support.
ODS9204E
DISS codes could not be loaded.
Please try again later or contact Support.
ODS9205E
Wiring diagram list cannot be displayed.
Please try again later or contact Support.
ODS9206E
Wiring diagram cannot be loaded.
Please try again later or contact Support.
ODS9207E
Vehicle data cannot be loaded.
Please try again later or contact Support.
ODS9208E
System for immobilizer adaptation system Please try again later or contact Support.
(FAZIT) not available.
ODS9209E
Possible errors cannot be loaded.
Please try again later or contact Support.
ODS9210E
Coding system (System42) not available.
Please try again later or contact Support.
ODS9211E
Flashing system (System42) not available.
Please try again later or contact Support.
ODS9212E
Login could not be completed. No access to Please try again later or contact Support.
dealer portal.
ODS9213E
The procedure cannot be completed. The group Please try again later or contact Support.
system is not available.
The data are stored temporarily and sent automatically when the group system is available
again and the Offboard Diagnostic Information
System Service is started on this computer.
ODS9214E
Key transponder reception system cannot be Please try again later or contact Support.
reached.
The data are stored temporarily and sent automatically when the group system is available
again and the Offboard Diagnostic Information
System Service is started on this computer.
ODS9215E
Diagnostic log reception system cannot be Please try again later or contact Support.
reached.
The data are stored temporarily and sent automatically when the group system is available
again and the Offboard Diagnostic Information
System Service is started on this computer.
381
Error Messages
ID
Displayed Error
Note
ODS9216E
The diagnostic log cannot be saved. The storage Please try again later or contact Support.
location is not available.
The log is encrypted and automatically stored
temporarily once the save location is available
again and Offboard Diagnostic Information System Service is started on this computer.
ODS9217E
Current equipment level reception system can- Please try again later or contact Support.
not be reached.
The data are stored temporarily and sent automatically when the group system is available
again and the Offboard Diagnostic Information
System Service is started on this computer.
ODS9218E
The template ... is missing in the GFF data. The Please contact Support.
test is cancelled.
ODS9219E
No URL was found in the configuration data for Please contact Support.
the alias ...
The test is cancelled.
Table 13.1. Error ID Table
13.2. Additional error messages
13.2.1. Firewall messages
When performing updates from Offboard Diagnostic Information System Service, there may be a firewall message.
Figure 13.2. Windows firewall message
Click the Do not block button to confirm this message.
382
Error Messages
Notice:
If the Continue blocking button is clicked, the firewall will block the update from being performed and the
program cancels the attempt.
13.2.2. Browser messages
Browser security warnings may appear in some cases. These messages appear after starting Offboard Diagnostic
Information System Service and calling up certain tabs for the first time that access a web group interface.
Figure 13.3. Browser security warning
Click the Yes button to confirm this message so the page can be displayed correctly.
If the No button is clicked, the page can only be displayed correctly after restarting Offboard Diagnostic Information System Service and clicking the Yes button.
383
Chapter 14. Index
Index
Symbols
#Loading, session, 330
A
Access authorization, 205
actual installation, 89, 104
Actual installation, 95
Actuator code, 197
Adaptation, 159
Adding OBD log periodically, 327
Admin, 52
Administration, 277
Antivirus protection, 303
Attaching OBD log, 327
B
Basic setting, 183
Binary coding, 175
Bluetooth interface, 25
Brand design, 280
Brand, licensed, 289
Browser error message, 383
Bus master, 166
C
Campaigns tab, 244
Cancel diagnosis, 66
Certificate, 26
Certificate selection, 26
Change diagnostic hardware, 65
Change display format, 95
Change sorting, 94
Change System Language, 281
Client area, 51
Client certificate, 316
Code, 51, 171
coded, 91
Coding assistant, 113
Coding status, 91
Coding the bus master, 166
Complete system DTC memory, 210
Complete test, 121
Component selection, 140
Components list, 89, 213
Concerns, 111
Control module list, 93
Control module, definitely installed, 91
Control Module-Specific Functions, 159
Control modules, 93, 101, 105, 153
Copying diagnostic log, 326
384
Index
Creating a test plan, 110
Customer code, 111
Cycle, update, 36
D
Data menu, 54
Database save location, 294
Dealer, 51
Dealer data, 293
Dealer number, 51
Dealer type, 289
Design, 280
Diagnosis, 52
diagnostic components destination directory, 21
Diagnostic connection, legal, 221
Diagnostic interface, 24
Diagnostic interface selection, 24
Diagnostic log, 298
Diagnostic object, 117
Diagnostic objects when flashing, 231
Diagnostic session save location, 295
display format, 104
Displaying OBD log, 327
DISS concerns, 111
Documents, 235, 242
DTC entry, 101
DTC memory, 101, 180
DVD, 18
E
E-mail outbox server, 302
E-mail outbox server mail settings, 302
E-mail size restriction, 303
End diagnosis, 66
End module, 143
Engine code, 248
Equipment characteristic, 105
Equipment list, 105
Equipment versions, 105
Erasing DTC memory entries, 181, 212
error classification, 358
error counter, 104
Error messages, 367
Extras menu, 55
F
Fault Code, 180
Fault Text, 180
Feedback, 300, 356
Firewall, 34, 303, 382
Flash,
Flash entrance, 221
Full screen, 57
Function description, 136
G
Gateway, 89, 166
385
Index
Gateway coding, 131
Gateway components list, 89
GFF, 107
GFF process, 291
Global configuration, 290
Guided Fault Finding, 107
Guided function, 100
H
Hardware part number, 103
Hardware version number, 103
Help menu, 56
Hotfix, 335
I
Identification, 191
Identifying control modules, 98
Ignition, 51
Importer, 51
Importer number, 51
Independent workshops, 67, 226
Info, 52
Info menu, 56
Information area, 50
Installation, 18
installation status, 90
interface, 50
K
KWP, 160, 172, 183, 193, 196, 197
L
Language, 281
License, 289
M
Mail server, 303
Manufacturer, 72
maximum installation, 95, 104
Measure Value Block, 193
Measured values, 129, 193
Menu Data, 53
mileage, 104
Mirror Server, 314
Model, 73
Model year, 73
Mouse, 57
N
Network, 51
Networking diagram, 96
New OBD log, 327
Notes, 366
O
OBD, 214
386
Index
On board diagnosis, 153
On Board Diagnostic, Context Menu Button, 98
Online help, 352
operated, 57
Operating modes, 52
Operating modes menu, 52
Order, 51
Order number, 51
Output diagnostic test mode, 196
P
part number, 191
PassThru, 25, 344
Perform test, 124
Performing a complete test, 121
Performing a test program, 124
Platform, 22
Platform selection, 22
PostSetup, 30
PR Numbers, 250
Print, 330
Print, diagnostic log, 325
priority, 358
Production date, 248
Production versions, 289
Provider, 303
Proxy server, 303
Q
Quick entrance, 148
R
Read DTC memory again, 99
Readiness code, 144
Reading/Entering the VIN, 70
readout plan, 91
Remote diagnosis head, 26
remote diagnosis head documentation, 25
Repair history, 245
Repair manual, 246
S
SAE Code, 180
Save, diagnostic log, 325
Saving, session, 330
Screenshot, 57
Search, 342
Select engine, 73
Select version, 99
Selective output diagnostic test mode, 197
Sending diagnostic log, 326
Sending external diagnostic log, 326
Sequential output diagnostic test mode, 197
Session, 295
setup.exe, 18
SMTP (Simple Mail Transfer Protocol, 303
Software part number, 103
387
Index
Software version, 191
Software version number, 103
sorting, 104
Special functions, 120
specified installation, 89
sporadic/static, 104
standard functions, 53
Standard order, 86
Start diagnosis, 66
Status, 104
status area, 56
Support contact data, 300
Support request, 356
System environment, 287
System identification, 191
System name, 103, 103
System Requirements, 17
T
tab bar, 51
Table of Contents, 15
Test baseline, 322
Test cancellation, 125
Test plan, 122, 124
Test program, 124
Touchscreen, 57
Transmission code, 248
Transport mode, 212
Trust certificate, 319
U
UDS, 163, 174, 185, 194, 199
Update, 36, 284, 284
user interface, 50
V
VAS5054, 25
Vehicle engine, 73
Vehicle features, 70
Vehicle features, flashing, 224
Vehicle ID, 51
vehicle status, 67
Vehicle-specific functions, 210
Version, 103
Versions, 73
Virtual keypad, 292
W
Warnings, 366
Windows security warning, 382
Wiring diagrams, 247
Work area, 51
388
Glossary
Amplitude
The maximum value that the amount of deflection of an oscillation in an alternating current (for example, in AC voltage) can reach.
Adaptation
This service enables interactive changing of parameters in the control system
that is being addressed. The changed values (for example, correction values
for idle speed) can be stored permanently in the control modules. The user has
the option to change the value and to transfer it into the temporary memory
(RAM) to check on the control module. The control module applies the new
values to its outputs and the user can check the system's reaction. If the right
correction value is found, the tester causes the control module to transfer the
value and the workshop code into the writable hard drive (EEPROM).
In contrast to basic setting, the affected control circuit is closed. With the
adaptation, system-specific parameters are determined and stored in the vehicle system.
ASAM-ODX
Association for Standardization of Automation and Measuring Systems
(http://www.asam.net)
Open Diagnostic Data Exchange
Baseline
A complete version of a DIDB. This contains all required artifacts, test programs and databases.
Operating Mode
Each of the tester's basic functions that can be accessed from the start screen:
"Flashing", "Diagnosis", "Information" and "Admin". Each operating mode
is divided into a range of individual functions.
Bluetooth
An industry standard for wireless transmission between devices over short
distances.
Client
A program on the PC that enables the connection to a server. A network client
is, for example, a program to that establishes the connection to a server in the
network so that the PC can be used as a work station in the network.
Diagnosis
Diagnostic connection
Connection socket for the diagnostic cable on the tester or in the vehicle.
Diagnostic object
Collective term for functions, build groups or components that can be diagnosed and are represented in the diagnostic object tree. Not to be confused with
diagnostic bus object (definition in DES-VW A11.0 owner's manual) And object (function, component or build group) on which the diagnostic function
is used.
Diagnostic objects should be named based on the Mutterliste. Even if this is
not currently the case, it must be done in the future so that wiring diagrams
on the tester can be requested according to Mutterliste terms from Elsa.
Diagnostic log
The diagnostic log contains a list of control modules with corresponding DTC
memory entries, DISS codes and text created manually.
DIDB
Direct current measurement
(inline current measurement)
Current measurement in which the tester is inserted directly into the circuit
like an ampere meter. Opposite: inductive current measurement via a clamp
connected tot he cable.
389
Glossary
DISS
The DISS system (Direct Information System Service) is used to record vehicle concerns and support the service core process.
- Recording concerns
- Reporting existing concerns
DTC
Diagnostic Trouble Code: an entry in the fault memory. It consists of the fault
location, fault types and ambient conditions, if necessary.
DTS (Softing)
Diagnostic Tool Set - software for creating diagnostic applications.
ECU
Electronic Control Unit: electronic control module.
Self Diagnosis
Vehicle systems are capable of self diagnosis. This means they have the ability
to continually check their own functions, connected sensors and actuators. A
malfunction results in the entry of an error code in the vehicle system DTC
memory. The tester contains all malfunctions in its knowledge base so that it
can allocate the error code to an error type and location after reading the DTC
memory and then create a test sample based on that.
Own test plan
Diagnostic strategy where the user selects possible faulty functions or components. If faults in the vehicle systems are detected during the diagnostic
sessions or a concern is entered, the test plan always differentiates between
the system test plan and the user's own test plan.
End module
An end module can consist of several function tests that start automatically
when exiting Guided Fault Finding. For example, feedback may be sent to the
vehicle manufacturer.
Incident code
Incident location
DTC memory
Rules of thumb
Logical relationship based on noticeable symptoms and/or symptoms from the
fault memory model, among each other or with each other. A rule of thumb can
be evaluated according to its reliability and assigned to one or more diagnostic
objects.
eShop
eShop is the system for ordering and licensing software and diagnostic data
within the Volkswagen Offboard Diagnostic Information System.
Vehicle identification
The vehicle is identified by determining the vehicle basic features (type, model year, version, engine code) that can be detected automatically or partially
automatically when a Gateway is present. Based on this data, a list of control
modules and equipment that may be installed is created and the vehicle system
test checks if these are installed or not.
Feedback
Error classification
Flash data
The flash data are sections of the programs that can be loaded for a vehicle
system.
Flash memory
Hard drive whose data remains intact even when there is no power supply. In
contrast to permanently programmed memory modules, a flash memory can
be updated with a corresponding update program (using the Flash CD).
Function
390
Glossary
Function test
Gateway components list
A Gateway control module knows the vehicle systems installed in the vehicle.
It monitors the vehicle systems and manages a status list. By checking the
Gateway components list, for example, a vehicle system can be queried if
its DTC memory is set, if it is coded or if communication is possible. The
components list is evaluated during vehicle identification and leads to a more
effective identification process.
Guided Fault Finding
In Guided Fault Finding, the diagnostic approach is integrated into an optimized process of vehicle identification, vehicle system test, test plan and function tests.
Guided Functions
Performing a vehicle specific function outside of GFF, for example, measuring
Basic setting
In basic setting, control modules are adapted to the peripheral devices.
Basic features
A vehicle is identified based on the type, model year, version and engine code.
Its equipment is then determined through a vehicle system test.
Hardware key, Hardware ID
Hardware features that are coded as a string of characters. The Hardware ID
is a component of the device-based licensing.
Hotfix
IP address
Abbreviation for "internet protocol address." Each computer that is connected to a computer network (TCP/IP) has its own unique IP address. It consists of four groups of numbers that are separated by periods (for example,
1.4.0.0.135). DHCP servers can assign IP addresses automatically.
Actual installation
Calibration
Precise adaptation of a tester (for example, current clamp) based on specifications and the correction of a measuring deviation through compensation of
a systematic error.
Maximum installation
Measurement
In measurements, you can complete measurements yourself whose results are
displayed numerically or graphically on the tester. A multimeter and oscilloscope (DSO) are available.
Measured value block
A fixed group of measured values that are read from a vehicle system.
Mirror server
A software package that is stored locally on the dealer server, for example,
and that maintains data for the VAS 505x update programs there. The dealer
server is connected centrally and receives current updates from there. Within the workshop, each tester connected to the LAN retrieves the current programs automatically when switched on or explicitly when the "Network update" function in Administration is run.
Offline
There is no active connection to a communication network.
Online
Active connection with a communication network such as the workshop network, the Volkswagen dealer network or the internet. See all Online connection.
Online log
A log that is sent to the vehicle manufacturer via the online connection.
Online connection
External connection such as one t the internet or VW server.
391
Glossary
Oscilloscope
Measurement and display unit for electrical signals that displays the progression of the signal strength over time (for example, oscillations).
D-PDU-API
The D-PUD-API is a standardized software interface for connecting diagnostic interfaces to the diagnostic software.
Platform
Protocols KW1281, KW2000,
KW6000, UDS
The keyword protocols determine the exact process for exchanging data between a control module and the tester. Older control modules communication
with KW1281. Newer control modules work with KW2000 or KW6000 (CAN
diagnosis). ASAM control modules work with UDS. In vehicle self diagnosis,
the tester determines the control module's keyword protocol version automatically before selecting diagnostic functions for the control module.
Provider
A service provider that offers communication services such as telephone,
wireless communication or internet.
Proxy server
A proxy sever is an exchange between clients and another network. It accepts requests from the client and forwards their data (sometimes modified or
anonymously) to the original source (in another network such as the internet).
Proxies can temporarily store the data locally (cache) for additional access.
Test plan
Weighted sequence of test programs that the operating system suggests to the
service technician for repairing the vehicle.
Test step
A self-contained unit in a function test.
Readiness code
8-digit binary code that indicates if all emissions- and safety-related diagnoses
were run by engine management.
Release notes
Version notes that accompany a software version. The version notes describe
functions that are new or have changed in comparison to the previous version.
Screenshot
Copy of the current screen content in a picture file.
Sensor
Device that receives measured values.
Server
In computer technology, a server refers to a central network computer. The
server makes the services or data available to the clients.
Definitely installed (control
module)
Specified installation
Start module
A start module can consist of one or more function tests that start automatically after the vehicle system test. They are used to check if new flash data
is available for a vehicle system.
Control module
Electronic device for controlling and monitoring vehicle functions such as
engine control module. Refer to ECU, vehicle system.
Test baseline
The developer version of a DIDB. It can be used to either expand or replace
the production data in the installation.
Touchscreen
A screen that also serves as an input device. By touching the contents of the
screen, the device (such as a computer or cell phone) can be controlled.
TB
392
Glossary
Traversal test
This type of test identifies control modules and derives information from them
that enables automatic vehicle identification. The test automatically cycles
through the equipment network structures.
UDS
Unified Diagnostic Services; a standardized protocol in accordance with ISO
14229 for control module communication. Based on KW2000 for ASAMODX control modules.
Update
Software modification package for updating existing software to a higher version.
1. New version of the operating system that is downloaded from the CD-ROM.
2. New programming version of a vehicle system that is downloaded from
the tester.
URL
Abbreviation for "Uniform Resource Locator". A URL is the address
of an internet resource such as a website, file, etc. Example: http://
www.volkswagen.de
Versions, version rule
The term is used in conjunction with the vehicle system equipment. Some
equipment such as an airbag may appear in different versions for an identified
control module. The basic task of the vehicle system test is to find out which
version is actually installed. If the version cannot be detected automatically,
the system will ask yes/no question about the equipment such as "Automatic
transmission?" The mechanisms for determining the versions are called version rules. Their results determine which diagnostic data will be made available.
Components list
List of the control modules installed in the vehicle.
Installation status
Verification
Workshop code
Certificate
License document that contains all authorizations, areas and characteristics of
the software and diagnostic data. The certificate is required to use the tester
software and is checked each time the application starts.
393