SPECIFICATIONS CT INGENUITY 128 NAME OF PRODUCT BRAND/ MANUFACTURER MODEL / TYPE Multislice CT Scan 128 SLICE Philips INGENUITY CORE 128 FACTORY OF ORIGIN PHILIPS HEALTHCARE (SUZHOU) Co.,Ltd,. CHINA Melalui PHILIPS MEDICAL SYSTEM (CLEVELAND) INC, UNITED States. PRODUCT'S REGISTRATION (AKL/AKD) KEMENKES RI AKL 21501410809 REFERENCE OF TECHNICAL X-Ray Tube & Generator Anode effctive heat capacity 30 MHU; direct cooling Anode Heat Storage Capacity 8 MHU 1,608KHU/min Anode cooling rate Large focal spot size Small focus spot size Segmented Anode Tube cooling system Direct Anode cooling Spiral groove bearing Maximum helical exposure time Generator power KV selections mA Range 1.0mm x 1.0mm 0.5mm x 1.0mm Yes Air cooled Yes Yes 100 sec 80 kW 80, 100, 120 & 140kV 20 - 665 mA Technology Low dose with Higher Image quality Improvement in spatial resolution and or reduction at low dose (iterative reconstruction) Generation of Reconstruction Significantly lower dose while simultaneously improving image quality Significantly improved spatial resolution (low noise / low-contrast detectability / spatial resolution) Signifiantly improved image quality (lower noise,improved low contrast, improved resolution) Yes , iDose 4 Generation 4 yes yes Yes Metal artifact reduction for large orthopedic implant (OMAR) Improves image quality through artifact prevention and increased spatial resolution at low dose, and reduces artifacts caused by large orthopedic implants Yes, OMAR New Technology for Scanning Automatic collimation after surview /topogram The system will automatically determine the optimal rotation time, pitch and collimation to deliver the best results automatically Plan the results, not the acquisition Facilitates optimal** management of image quality and radiation dose with patient-specifi methods CT Dose Check notification on parameter and radiation dose with patientspecific methods yes, with ipatient technology yes, with ipatient technology yes, with ipatient technology yes, with ipatient technology yes, with ipatient technology Dose Management Adhere to ALARA Principles ACS (Automatic Current Selection) Dynamic Dose Modulation (DDOM) z-axis Dose Modulation (zDOM) Display of CTDIvol and DLP during planning Yes. DoseWise Principles DoseRight ACS DoseRight D-DOM DoseRight z-DOM Yes. Dedicated Pediatric Protocols Yes. GANTRY Gantry Aperture 360° Rotation Speeds 70 cm Slices Gantry controls on right and left of gantry Gantry controls on front and back of gantry Maximum Scan FOV 50cm Tilt Gantry Cooling Method Laser positioning lights Intercom system 128 Yes Yes DETECTOR Solid State CT Detector Number of detector rows Number of slice per rotation Transfer rate (speed) of slip ring Data sampling rate Slice collimations Area coverage per scan rotation 0.4 sec for full 360º scan, Effctive cardiac rotation time 0.3 seconds 25 & 50 cm ± 30° in 0.5° increment Air Cooling Yes Yes Yes, Gadilinium Oxisulfide (GOS) 64 128 5.3 Gbytes/sec 4640 views/rev/element 64 x 0.625mm, 40 x 0.625 mm, 20 x 0.625 mm, 16 x 0.625 mm, 12 x 0.625 mm, 8 x 0.625 mm, 4 x 0.625 mm, 2 x 0.625 mm, 32 x 1.25 mm, 12 x1.25mm 40 mm Reconstruction and Image Quality Recon FOV Standard reconstruction matrix Ultra High reconstruction matrix Spatial Resolution Noise Absorption Range Standard reconstruction speed Adaptive multicycle reconstruction for Cardiac Temporal resolution 5-50cm 512 x 512 768 x 768 & 1024 x 1024 matrix 24 lp/cm 0.27% -1024 to +3071 Hounsfield units 25 image /sec Yes 0.053 sec Patient Table Sannable range Longitudinal speed Z- position accuracy Remote Table control from Console 1750 mm 0.5-185 mm/sec ± 0.25 mm yes, up/down, in/out Scanner Console Operating System Screen size (diagonal) Monitor Resolution Remote control from console Windows 19" 2 x LCD monitor 1280 x 1024 Table: Up/down, In/out Dicom DICOM 3.0 configuration, DICOM print/store, DICOM send Dicom CD writer Filming Scan time showed on console CT Dose Index showed on console Dose Length Product showed on console yes yes yes yes yes Scanner User Environment Combined acquisition and image processing console Scan control Box Two-way Intercom System Bolus Tracking - Track constrast medium to trigger scanning using multiple ROI Comply Comply Comply Comply Automated Contrast bolus triggering Prospective ECG gating /triggering Retrospective tagging Adaptive multi-cycle reconstruction algorithm Integrated ECG Monitor Cardiac Viewer CT Reporting Dose management Yes Yes Yes Yes Yes Yes Yes Yes Image Processing/Review Slab Viewer Cursor for pixel value measurements Angle measurements Double Window: Simultaneous displays of two independent CT density ranges on the same image Invert Window RelateSlice 3D Small Volume Analysis Curved MPR viewing 3D display viewing Volume rendering viewing Maximum Intensity Projection (MIP) Minimum Intensity Projection (minIP) Volume Intensity Projection (VIP) ROI Volume Calculation CT Number Display cine yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes yes Workstation (ISP) Operating system Memory Windows series 16GB MPR Yes Available planes in multi planar reformatting 5 planes includes orthogonal, axial, sagittal, coronal, curved MIP and mMIP Small volume analysis to measure tumors and/ or organ Support of external USB 2.0 data storage devices Medium DVD/CD-RW Yes Yes Yes Yes Tool to show survey scan as localizer for multi planar reformatting display Yes Function to displays a moveable, mini-window which can be set with its own windowing, image enhancement and rendering parameters to enhance Yes visualization and assessment of certain elements of the image, while maintaining optimal viewing parameters for the main viewport Windowing presets CT Comprehensive Cardiac Analysis Application to assess the state of the coronary arteries and to analyze functional heart data Tools to performs a full segmentation procedure, segmented entire organ at one time based on a pre-defined model Number of segmentation model Tools to view details of the segmentation, make manual corrections, save the segmentation, and apply a new segmentation algorithm Yes Yes Tools to perform quantitative measurements concerning the coronary arteries as percent stenosis and cross-sectional area based on automatic lumen contouring or manual methods Able to display ECG Graphic Yes, With Comprehensive Cardiac Analysis Able to shows the heart with blood in the cavities removed as MIP Able to shows a 2D Cartesian display of the heart’s surface Tools to shows a MIP image of the heart’s surface based on the coronary centerlines in true anatomic orientation of the heart Tools to shows a 3D map mapped onto a sphere as MIP Automatic contours tools CT Functional Analysis Cardiac CT Calcium Scoring CT Angio CT Automatic bone removal - cranial CT Automatic bone removal - CTA CT Virtual Colonoscopy CT Brain Perfusion The package should generates quantitative color maps of cerebral blood flow (CBF), cerebral blood volume (CBV), mean transit time (MTT) and timeto-peak (TTP), in addition to summary maps. yes, with CCA yes Yes Yes Yes Yes Yes, With Advanced Brain Perfusion Yes CT Brain Perfusion with Summary Map Yes, With Advanced Brain Perfusion to differentiates areas of increased blood volume and decreased blood flow and presents this information in a summary map to help clinicians Yes distinguish between still-viable and non-viable infarcted tissue. CT Advanced vessel analysis Application for general vascular analysis and stent planning from body and skull (head and neck) studies Able to perform automatic vessel centerline extraction Able to perform automatic vessel labeling of major vessels Allows visualization of calcium in the vessels Head vessel name list Functions to allows to add vertices beyond the distal and proximal ends of the extracted vessel centerline, and select which end will be continued from Function to allows to view in a semitransparent mode all volumetric anatomy that has been removed included anatomy removed automatically and manually Yes Yes, with AVA CT Advanced Vessel Analysis - Stent Planning Stent Planning Packages with Auto centerline detection tools to provide the basis for accurate reproducible quantitative measurements of vascular structures for planning endoluminal stent to repair aneurysms, stenosis and other vascular abnormalities Yes Yes, with AVA Stent Palnning Liver Analysis Package segmentation tools to facilitate for assessing the liver, hepatic vasculature of individual vascular segments, and physician-identified lesions Able to Perform segmentation of the liver tissue, vessels, and lesions Mode of Liver Segments selections to determine Able to determine 8 segments Coinaud Able to determine 9 segments Bismuth Available list of segments to place landmark seeds Yes, With Liver Analysis The application enables absolute and relative volume measurements as well as virtual hepatectomy for RF ablation and surgery planning. CT Lung Nodule Assestment for volumetric analysis of pulmonary nodule or lesion size over time, and to accurately assess the nodule's doubling time growth rate. yes, with Lung Nodule Assestment Yes CT Virtual Endoscopy Yes, comply CT Viewer Yes, comply CT Reporting Yes, comply with reporting capabilities for paper print of clinical results including display Yes of key images and results frames. Acessories & Support Service and Warranty 1 Tahun On-Site training Injector Dual Head Dicom Printer