Uploaded by Rafael Ramirez Casate

54-2-A710-ENLARGED SECTIONS

advertisement
SINGLE PLY TPO ROOF OVER RIGID
POLYISOCYANURATE & LWIC
SMOKE VENTS - BABCOCK DAVIS
STC50 MIN. OITC 39 **OR SIMILAR**
NEW STAGE ROOF
64' - 0"
STL. PLATE
HANGERS
ALL RIGHTS ARE RESERVED. ANY POSSESSION, REPRODUCTION OR OTHER USE OF THIS DOCUMENT, WITHOUT THE WRITTEN CONSENT OF CURRIE SOWARDS AGUILA ARCHITECTS INC., IS PROHIBITED.
Architecture, Planning,
Interiors, &
Sustainable Design
STRUCTURAL STEEL STAGE GRID
AA26001584
STAGE GRID
185 NE 4TH AVENUE SUITE 101
DELRAY BEACH, FL 33483
STRUCTURAL "C" CHANNEL. SEE
STRUCTURAL PLANS
T:(561) 276-4951 F:(561) 243-8184
E-MAIL: office@csa-architects.com
CAST IN PLACE CONCRETE BEARING
WALL - SEE STRUCTURAL DRAWINGS
ISSUED FOR :
CAST IN PLACE CONCRETE BEARING
WALL - SEE STRUCTURAL DRAWINGS
BIDS
PERMIT
CONSTRUCTION
EXISTING PROSCENIUM WALL TO BE CUT
& PARTIALLY REMOVED SO TOP OF WALL IS
AT THE SAME ELEVATION AS THE EXISTING
PARAPET WALL. PROVIDE EXPANSION JOINT /
EXPANDABLE FLASHING AT INTERFACE BETWEEN
EXISTING WALL AND NEW WALL.
EXPOSED CONCRETE INTERIOR
SEAL
EXISTING BRACING BETWEEN JOISTS
TO BE MODIFIED TO ALLOW MIN.
6'-8" CLEAR HEAD ROOM AT NEW CATWALK
EXISTING ACOUSTIC REFLECTOR TO BE
V.I.F. & MODIFIED AS REQUIRED FOR MIN 6'-8"
HEADROOM
STEEL CATWALK STRUCTURE SEE
DETAILS
V.I.F. EXISTING JOIST
LOCATIONS
JESS M. SOWARDS
FL. REG# AR0013205
PROJECT TITLE
MALTZ JUPITER
THEATRE
RENOVATION
EXISTING ACOUSTIC REFLECTOR V.I.F.
MIN.
6' - 8"
NEW THIRD
FLOOR
27' - 0"
EXIST. PROSCENIUM WALL
NEW PROSCENIUM WALL
22' - 0"
22' - 0"
NEW PROSCENIUM OPENING BEAM
SEE STRUCTURAL
STEEL CATWALK STRUCTURE SEE
DETAILS
CUT & REMOVE TOP OF EXIST.
PROSCENIUM OPENING
1001 EAST INDIANTOWN
ROAD
JUPITER FL 33477
EXISTING STEEL CATWALK TO
REMAIN
REVISIONS
NUM.
DESCRIPTION
DATE
INSTALL S.A. TRANSFER DUCT
FROM EXISTING PLENUM TO
NEW ORCHESTRA PIT
12' - 0"
12' X 10' O.H. DOOR
5
2-A410
STAGE CENTER
Sim
EXISTING CONCRETE BEARING WALL
TO REMAIN
1" FORM DECK. SEE STRUCTURAL
PLANS
EXIST.
SLAB
1ST FLOOR
0' - 0"
10"
NEW
SLAB
EXISTING CONCRETE SLAB TO
REMAIN
SUB GRADE WATERPROOFING - SEE
DETAILS
03019
10' - 8"
EXIST. S.A. PLENUM
8” REINFORCED MASONRY WALL SEE STRUCTURAL DRAWINGS
ORCHESTRA PIT
03017
2' - 6"
EXISTING ORCHESTRA PIT
FLOOR - PARTIALLY DEMOLISHED
AS REQUIRED
SUB GRADE WATERPROOFING - SEE
DETAILS
SUB GRADE WATERPROOFING - SEE
DETAILS
1
2-A710
WALL SECTION - WEST STAGEHOUSE WALL
1/4" = 1'-0"
EX BASEMENT
-8' - 0"
CAST IN PLACE CONCRETE BEARING
WALL - SEE STRUCTURAL DRAWINGS
SUB GRADE WATERPROOFING - SEE
DETAILS
NEW ORCHESTRA
PIT
-11' - 6"
SEQ. 2 90% CONSTRUCTION DOCUMENTS: 09.09.2019
NEW SECOND
FLOOR
13' - 6"
9/10/2019 9:20:37 AM
THIS DOCUMENT IS THE PROPERTY OF CURRIE SOWARDS AGUILA ARCHITECTS INC.
STAGE GRID
LEVEL
52' - 9"
3/4" 2-COAT STUCCO WITH SMOOTH
TEXTURE. PAINTED
THESE DRAWINGS ARE PREPARED
PER ESTABLISHED INDUSTRY
STANDARDS AND REPRESENT THE
ARCHITECT AND ENGINEERS DESIGN
CONCEPT. THEY ARE NOT INTENDED
TO PROVIDE EVERY DETAIL OR
CONDITION REQUIRED TO
CONSTRUCT THE BUILDING. THE
CONTRACTOR THROUGH
SUBMITTALS AND OTHER
COORDINATION EFFORTS IS FULLY
RESPONSIBLE FOR PROVIDING A
COMPLETE AND OPERATIONAL
BUILDING WHETHER INDICATED ON
THE PLANS OR NOT.
C:\Users\Owner\Documents\180801-MALTZ
JUPITER THEATRE
RENOVATION_yanelleHKMWG.rvt
DRAWING TITLE
ENLARGED
SECTIONS
DATE
DRAWN BY
1-14-2019
EL
JOB NUMBER
180801
DRAWING NUMBER
2-A710