eSure™ Rectifier DC Power for Business-Critical Continuity™ R48-3200e eSure™ Rectifier -48 V DC, 3200 W Features and Benefits Optimized depth-reduced footprint allows installation in short-depth racks and cabinets DSP (Digital Signaling Processor)means fewer components, optimized operation and active load sharing for increased reliability Description The eSure™ R48-3200e rectifier converts standard AC supply voltages into stable nominal-48V DC voltage adjustable to the needs of the application. The R483200e is a constant power rectifier designed with the latest patented switchmode technology using DSP (Digital Signaling Processor) functionality for efficient operation. For a higher load capacity, rectifiers can be connected in parallel and intelligent control can be added with the help of a separate controller. Compliant with global standardsdelivers quality, performance and reliability no matter what the application or location demands High efficiency, near 97%-reduces power consumption for lower operating costs Hot pluggable-facilitates future extensions Wide input voltage range-operates in the most demanding environments where input voltage changes Wide temperature operating range (-40°C / -40 °F to +75°C / 167°F) -meets the harshest climatic environment requirements R48-3200e eSure™ Rectifier DC Power for Business-Critical Continuity™ R48-3200e Technical Specifications, R48-3200e DC Output Output Voltage, Adjustment Range Output Power Output Power, Derated for Input Voltage Output Current Output Current limit set Point Efficiency Psophometric noise (system) Temperature Derating Output power vs. Temperature at 264V ≥Vin ≥176 Vac % of output power 200 to 250 V AC 85 to 300 V AC 45 to 65 Hz 17 A 0.99 <5% from 50 to 100% of rated load -42 to -58 V DC 3200W@Vout >48VDC See Diagram 67A 0 to 67 A 96.8% peak <2 mV typical <32 dBrnc typical See diagram -20 0 20 40 60 80 100 Output power vs. Input voltage and Vo >48V at Temp≤45°C Alarm and status reported via CAN bus to system Controller Green LED = Normal operation; Yellow LED = Alarm; Red LED = Failure; Flashing red LED = Fan failure 120 100 80 60 40 20 0 0 50 100 150 200 250 300 350 -40 to +75°C, -40 to +167°F Temperature Range, Storage -40 to +75°C, -40 to +167°F Relative Humidity Altitude EMC Safety 0 to 95% 2000 m, 6560 ft at full power ETSI EN 300 386 class B, FCC CFR 47 Part 15 class B, Telcordia GR-1089-CORE class B IEC 60950, EN 60950, UL 60950 Mechanics Dimensions (H×W×D) Weight 132×85.3×287mm / 5.2×3.36×11.3 inches 3.1 kg / 6.8 lbs Output voltage v.s. Output current at max. Power 3200W Output Voltaqe(V) Environmental Temperature Range, Operating Ordering information Description Rectifier 48V,3200W -40 Input voltage (VAC) Control and Monitoring Rectifier Alarm and Signaling Visual Indications Other parts Controller Units 120 100 80 60 40 20 0 Temperature (°C) % of output power AC Input Input Voltage, Nominal Input Voltage, Permitted Variation Line Frequency Max Input Current Power Factor THD (Total Harmonic Distortion) Efficiency Curve Efficiency 97.5 97.0 96.5 96.0 95.5 95.0 94.5 94.0 93.5 93.0 96.69 96.80 96.53 96.11 95.41 95.53 93.39 0 10 20 30 40 50 60 70 80 90 100 Product name R48-3200e www.emersonnetworkpower.com www.emersonnetworkpower.com/energysystems www.DCpowerefficiency.com 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Output current(A) See separate ACU/ACU+ and SCU/SCU+ datasheets Emerson Network Power. The global leader in enabling Business-Critical Continuity™ 60 50 40 30 20 10 0 Load (% of rated load) AC Power Embedded Power Precision Cooling Connectivity Monitoring Racks & Integrated Cabinets DC Power Outside Plant Services Embedded Computing Power Switching & Controls Surge Protection Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2009 Emerson Electric Co. Emerson Network Power reserves the right to alter without notice the specification, design or conditions of supply of any product or service. 2009.9