eSure™ Rectifier DC Power for Business-Critical Continuity™ R48-3200e eSure™ Rectifier -48 V DC, 3000 W Features and Benefits Optimized depth-reduced footprint allows installation in short-depth racks and cabinets DSP (Digital Signaling Processor)means fewer components, optimized operation and active load sharing for increased reliability Description 2 nominal-48V DC voltage adjustable to the needs of the application. The R482 mode technology using DSP (Digital Signaling Processor) functionality for control can be added with the help of a separate controller. Compliant with global standardsdelivers quality, performance and reliability no matter what the application or location demands power consumption for lower operating costs Hot pluggable-facilitates future extensions Wide input voltage range-operates in the most demanding environments where input voltage changes Wide temperature operating range (-40°C / -40 °F to +65°C / 149°F) -meets the harshest climatic environment requirements R48-3200e eSure™ Rectifier R48-3200e Technical Specifications, R48-3200e DC Output Output Voltage, Adjustment Range Output Power Output Power, Derated for Input Voltage Output Current Output Current limit set Point Psophometric noise (system) Temperature Derating 200 to 250 V AC 85 to 300 V AC 45 to 65 Hz 16 A 0.99 <5% from 50 to 100% of rated load % of output power Output power vs. Input voltage and Vo > 48V at Temp≤45°C 60 40 20 50 100 150 200 250 300 350 R48-3200e Output voltage v.s. Output current at max. Power 3000W 60 50 40 30 20 10 0 Alarm and status reported via CAN bus to system Controller Green LED = Normal operation; Yellow LED = Alarm; Red LED = Failure; Flashing red LED = Fan failure -40 to +65°C, -40 to +149°F Relative Humidity Altitude EMC Safety 0 to 95% 2000 m, 6560 ft at full power ETSI EN 300 386 class A,EN55022 Class A IEC 60950, EN 60950, UL 60950 Mechanics Dimensions (H×W×D) Weight 132×85.3×287mm / 5.2×3.36×11.3 inches 3.1 kg / 6.8 lbs % of output power Temperature Range, Storage 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 Output Current (A) R 48-3200e Output power vs. Temperature at Uin > 176 Vac 120 100 80 60 40 20 0 -40 -20 0 20 40 60 80 Output Current(A) Efficiency Curve Efficiency -40 to +65°C, -40 to +149°F Ordering information Description 80 Input voltage (Vac) Environmental Temperature Range, Operating Other parts Controller Units 100 0 Control and Monitoring Visual Indications 120 0 -42 to -58 V DC 3000W@Vout >48VDC See Diagram 62.5A 0 to 62.5 A 96% peak <2 mV typical <32 dBrnc typical See diagram Output Voltaqe(V) AC Input Input Voltage, Nominal Input Voltage, Permitted Variation Line Frequency Max Input Current Power Factor THD (Total Harmonic Distortion) See separate ACU/ACU+ and SCU/SCU+ datasheets 98 96 94 92 90 88 86 84 0 10 20 30 40 50 60 70 80 90 100 Load (% of rated load) Product name R48-3200e Emerson Network Power. The global leader in enabling Business-Critical Continuity™. www.emersonnetworkpower.com www.emersonnetworkpower.com/energysystems Product Code 1R483000eXXX AC Power Embedded Power Precision Cooling Connectivity Infrastructure Management & Monitoring Racks & Integrated Cabinets DC Power Outside Plant Services Embedded Computing Power Switching & Controls Surge Protection Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2012 Emerson Electric Co. 2012.3