DC Power Systems for Business-Critical Continuity NetSure 801 Series DC Power System NetSure 801 Series DC Power System Features Wide AC input range from 260V to 530Vac System efficiency up to 93% Hot swappable rectifier and monitoring module Front access, top / bottom cable entry Remote monitoring through RJ45, RS232 and replay output Surge protection on AC,DC and signal side Introduction NetSure 801 power system is a new generation of highly reliable power system designed by Emerson. The system can be smoothly expanded up to 6000A through parallel connection. It is applicable for following applications: Large and medium switching office Level-1 transmission backbone line GSM mobile switching office, mobile tandem exchange CDMA mobile switching office, mobile tandem exchange System Configuration Easily expandable with more power or feature when new demand arise Rectifier R48-5800 Monitor M810G Utilize CE/UL approved rectifier R48-5800 AC Distribution Cabinet (PD380/400AFH-6, PD380/630AFH-6, PD380/630AFA-6) DC Distribution Cabinet (PD48/1600DF-6, PD48/2500DF-6, PD48/2000HF-6/X1) Rectifier Cabinet (Rack1000-6, Rack2000-6) System comply with EN60590 and EN300386, ROHS System Electrical Specifications Input Voltage Range 260 Input Frequency Range 45 Power Factor Efficiency Nominal Output Voltage 530Vac (half power at 260 65Hz 0.99 93% -42Vdc Load Sharing -58Vdc 1% Environmental NetSure 801 Series DC Power System Operating Temperature Relative Humidity Elevation Storage Temperature -10 +65 95% RH 4200m -40 +70 (derating from 45 ) 304Vac) Monitoring Module M810G NetSure 801 Series DC Power System AC Distribution Cabinet Features Menu operated and user friendly Configurable 8 pcs replay output and 4 pcs digit input Remote monitoring through RJ45, RS232, modem, support TCP/IP, SNMP, web browser Features Up to 400 alarm history logs Built-in CPU, independent monitoring Backlit large LCD display of AC voltage, current, frequency and status of lightning arrester M810G Intelligent battery monitoring Visual and audible alarms Features Wide AC input range from 260V to 530Vac System efficiency up to 93% Rectifier can output 50% power in phase-missing conditions Hot swappable rectifier and monitoring module Front access, top / bottom cable entry Remote monitoring through RJ45, RS232 and replay output Introduction NetSure 801 power system is a new generation of highly reliable power system designed by Emerson. The system can be smoothly expanded up to 6000A through parallel connection. It is applicable for following applications: Large and medium switching office Level-1 transmission backbone line GSM mobile switching office, mobile tandem exchange CDMA mobile switching office, mobile tandem exchange Rectifier Module R48-5800 General Safety CE,UL EN60950: 1992,UL1950 EMC EN55022 Class B Enclosure IP20 MTBF > 390000 hours Input Characteristics System Configuration Range Unit Remark V Half power at 260 Voltage 260 Rectifier R48-5800 Monitor M810G Line Frequency 45 Power Factor 0.99 Easily expandable with more power or feature when new demand arise AC Distribution Cabinet (PD380/400AFH-6, PD380/630AFH-6, PD380/630AFA-6) DC Distribution Cabinet (PD48/1600DF-6, PD48/2500DF-6, PD48/2000HF-6/X1) Rectifier Cabinet (Rack1000-6, Rack2000-6) THD 5% System Electrical Specifications Input Voltage Range Input Frequency Range Power Factor Efficiency Nominal Output Voltage 260 45 DC emergency lighting available in case of mains failure Expandable up to 5 AC cabinets R48-5800 Output Power Surge protection on AC,DC and signal side Utilize CE/UL approved rectifier R48-5800 System comply with EN60590 and EN300386, ROHS Visual and audible alarm Two mains auto/manual switchover Front access, top / bottom cabling 530Vac (half power at 260 65Hz 0.99 304Vac) 530Vac 65 Lightning proof and electrical insulation in compliance with IEC standard, ROHS compliant 100% 304Vac 50% Hz Output Characteristics Range Unit Remark Voltage -42 Vdc 100% Current 0 A 50% Power 5800 W 100A@-58V Power Density 0.813 W/cm 3 Size used: 85H 224W 371D Efficiency 93% 40% 100% load Peak to peak noise 50 mV 0 Psophometric weighted noise 0.5 mV (300 260 304 530 Output Power VS Input Voltage 50% 110% load 122 Output Power Temperature -40 0 40 60 Output Power VS Temperature 20MHz 3400Hz) 93% -42Vdc Load Sharing -58Vdc Rectifier Cabinet Configuration 1% Rack1000-6 Rack2000-6 M810G 0 1 R48-5800 1 10 M810G 0 1 R48-5800 1 20 *Note: One M810G supports up to 60 R48-5800 rectifiers. Environmental NetSure 801 Series DC Power System Operating Temperature -10 +65 (derating from 45 ) Model HxWxD(mm) Rack1000-6 2000 600 600 600 600 Relative Humidity 95% RH Rack2000-6 2000 Elevation 4200m R48-5800 88 M810G 87.5 Storage Temperature -40 +70 244 372 243.5 Weight (kg) 161 2 Remark 150 Not including rectifiers 180 Not including rectifiers 7.8 PD380/400AFH-6/X1 PD380/630AFH-6/X1 PD380/630AFA-6/X1 AC Input AC Output DCEmergency Output 3 phase / 5 line 3 phase / 5 line 3 phase / 5 line Manual switchover Manual switchover Automatic switchover 400A/3Px2 630A/3Px2 630A/3Px2 4 160A/3P(MCCB) 6 160A/3P(MCCB) 6 160A/3P(MCCB) 1 63A/3P(MCB) 1 63A/3P(MCB) 1 63A/3P(MCB) 1 32A/3P(MCB) 1 32A/3P(MCB) 1 32A/3P(MCB) 3 32A/1P(MCB) 3 32A/1P(MCB) 3 32A/1P(MCB) 3 20A/1P(MCB) 3 20A/1P(MCB) 3 20A/1P(MCB) 100A/48V 100A/48V 100A/48V Input Voltage 0 -58 Input / Output Specifications Including faceplate Rack 1000-6 Rack 2000-6 Mechanical Specifications Model H x W x D(mm) PD380/400AFH-6/X1 2000 800 600 Weight(kg) 240 PD380/630AFH-6/X1 2000 800 600 260 PD380/630AFA-6/X1 2000 800 600 300 Monitoring Module M810G NetSure 801 Series DC Power System AC Distribution Cabinet Features Menu operated and user friendly Configurable 8 pcs replay output and 4 pcs digit input Remote monitoring through RJ45, RS232, modem, support TCP/IP, SNMP, web browser Features Up to 400 alarm history logs Built-in CPU, independent monitoring Backlit large LCD display of AC voltage, current, frequency and status of lightning arrester M810G Intelligent battery monitoring Visual and audible alarms Features Wide AC input range from 260V to 530Vac System efficiency up to 93% Rectifier can output 50% power in phase-missing conditions Hot swappable rectifier and monitoring module Front access, top / bottom cable entry Remote monitoring through RJ45, RS232 and replay output Introduction NetSure 801 power system is a new generation of highly reliable power system designed by Emerson. The system can be smoothly expanded up to 6000A through parallel connection. It is applicable for following applications: Large and medium switching office Level-1 transmission backbone line GSM mobile switching office, mobile tandem exchange CDMA mobile switching office, mobile tandem exchange Rectifier Module R48-5800 General Safety CE,UL EN60950: 1992,UL1950 EMC EN55022 Class B Enclosure IP20 MTBF > 390000 hours Input Characteristics System Configuration Range Unit Remark V Half power at 260 Voltage 260 Rectifier R48-5800 Monitor M810G Line Frequency 45 Power Factor 0.99 Easily expandable with more power or feature when new demand arise AC Distribution Cabinet (PD380/400AFH-6, PD380/630AFH-6, PD380/630AFA-6) DC Distribution Cabinet (PD48/1600DF-6, PD48/2500DF-6, PD48/2000HF-6/X1) Rectifier Cabinet (Rack1000-6, Rack2000-6) THD 5% System Electrical Specifications Input Voltage Range Input Frequency Range Power Factor Efficiency Nominal Output Voltage 260 45 DC emergency lighting available in case of mains failure Expandable up to 5 AC cabinets R48-5800 Output Power Surge protection on AC,DC and signal side Utilize CE/UL approved rectifier R48-5800 System comply with EN60590 and EN300386, ROHS Visual and audible alarm Two mains auto/manual switchover Front access, top / bottom cabling 530Vac (half power at 260 65Hz 0.99 304Vac) 530Vac 65 Lightning proof and electrical insulation in compliance with IEC standard, ROHS compliant 100% 304Vac 50% Hz Output Characteristics Range Unit Remark Voltage -42 Vdc 100% Current 0 A 50% Power 5800 W 100A@-58V Power Density 0.813 W/cm 3 Size used: 85H 224W 371D Efficiency 93% 40% 100% load Peak to peak noise 50 mV 0 Psophometric weighted noise 0.5 mV (300 260 304 530 Output Power VS Input Voltage 50% 110% load 122 Output Power Temperature -40 0 40 60 Output Power VS Temperature 20MHz 3400Hz) 93% -42Vdc Load Sharing -58Vdc Rectifier Cabinet Configuration 1% Rack1000-6 Rack2000-6 M810G 0 1 R48-5800 1 10 M810G 0 1 R48-5800 1 20 *Note: One M810G supports up to 60 R48-5800 rectifiers. Environmental NetSure 801 Series DC Power System Operating Temperature -10 +65 (derating from 45 ) Model HxWxD(mm) Rack1000-6 2000 600 600 600 600 Relative Humidity 95% RH Rack2000-6 2000 Elevation 4200m R48-5800 88 M810G 87.5 Storage Temperature -40 +70 244 372 243.5 Weight (kg) 161 2 Remark 150 Not including rectifiers 180 Not including rectifiers 7.8 PD380/400AFH-6/X1 PD380/630AFH-6/X1 PD380/630AFA-6/X1 AC Input AC Output DCEmergency Output 3 phase / 5 line 3 phase / 5 line 3 phase / 5 line Manual switchover Manual switchover Automatic switchover 400A/3Px2 630A/3Px2 630A/3Px2 4 160A/3P(MCCB) 6 160A/3P(MCCB) 6 160A/3P(MCCB) 1 63A/3P(MCB) 1 63A/3P(MCB) 1 63A/3P(MCB) 1 32A/3P(MCB) 1 32A/3P(MCB) 1 32A/3P(MCB) 3 32A/1P(MCB) 3 32A/1P(MCB) 3 32A/1P(MCB) 3 20A/1P(MCB) 3 20A/1P(MCB) 3 20A/1P(MCB) 100A/48V 100A/48V 100A/48V Input Voltage 0 -58 Input / Output Specifications Including faceplate Rack 1000-6 Rack 2000-6 Mechanical Specifications Model H x W x D(mm) PD380/400AFH-6/X1 2000 800 600 Weight(kg) 240 PD380/630AFH-6/X1 2000 800 600 260 PD380/630AFA-6/X1 2000 800 600 300 DC Distribution Cabinet Features Built-in CPU, independent monitoring Backlit large LCD display of DC status Visual and audible alarm Input / Output Specifications PD48/1600DF-6/X1 PD48/2500DF-6/X1 PD48/2000HF-6/X1 Battery fuse 2 1000A(NT4) 2 1000A(NT4) 2 DC Output 6 500A(NT3) 8 630A(NT3) 120 Front access, top / bottom cabling 2 200A (NT2) 4 400A (NT2) (High ohmic Visual and audible alarm Expandable up to 8 DC cabinets Lightning proof and electrical insulation in compliance with IEC standard, ROHS compliant 8 100A (NT00) 4 200A (NT2) distribution,30m ) 6 63A(NT00) 8 100A(NT00) 6 63A(NT00) 1000A(NT4) 10A (MCB) Mechanical Specifications Model H x W x D(mm) PD48/1600DF-6/X1 2000 800 600 Weight(kg) 280 PD48/2500DF-6/X1 2000 800 600 320 PD48/2000HF-6/X1 2000 800 600 270 Emerson Network Power Co., Ltd. No. 1 Kefa Rd., Science & Industry Park, Nanshan District 518057, Shenzhen China T: 86-755-86010808 F: 86-755-86010909 Emerson Network Power The global leader in enabling business-critical continuity. AC Power Embedded Computing Connectivity DC Power www.emersonnetworkpower.com.cn www.emersonpower.com.cn Outside Plant Racks and Integrated Cabinets Embedded Power Power Switching & Controls Services Monitoring Precision Cooling Surge Protection Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. E-X6210599-0807 C 2007 Emerson Electric Co. DC Power System Benefits z Rectifier module adopts DSP technol- z ogy power density up to 15.8W/in3 Wide input voltage range (85 to 290 Vac), adaptable to various grids z Front access and space efficient. System can be positioned next to wall z Intelligent battery management func- PS48600-3/2900-X5 PS48400-3/2900-X5 Medium System tion that expands lifetime z Hot swap and online manitenance Emerson Network Power has developed PS48600-3/2900, PS48400-3/2900 medium power system with many years' R&D and operation experiences. The system adopts DSP technology, completely meeting demands of customers worldwide with high reliability, high efficiency and high performance. The system includes 2series products: PS48600-3/2900 2m cabinet, including 12 rectifiers of total capacity up to 600A; PS48400-3/2900 1.6m cabinet, including 8 rectifiers of total capacity up to 400A. The rectifier is equipped with high efficiency, high reliability, super-low radiation and easy maintenance and fully meets -48Vdc power demands of medium and large mobile base stations, medium exchanges, transmission relay stations, microwave communications stations and satellite communications stations Applications PS48600-3/2900-X5 z 2G, 3G mobile base stations z z Medium exchanges, rural telecom networks and access networks Transmission relay stations z Microwave/satellite communications stations Key Features PS48400-3/2900-X5 6 z Rectifier module adopts DSP technology with efficiency up to 93% and power density of 15.8W/in3 z In compliance with international standards such as CE and applicable for residential environment z Wide input voltage range (85 to 90Vac), adaptable to poor electric power z Rectifier module can operate in an environment of 65 z Rectifier ID identifying function, convenient for customer assets management z z Digitized current sharing technology with high stability and precision up to 3% Intelligent battery management function that expands lifetime z Complete AC, DC and signal port lightning proof z Highly intelligent in monitoring and remote control z Hot swap and online manitenance Business-Critical Continuity M500F Monitoring Module M500F monitoring module adopts built-in Intel 80386EX CPU as main controller, RTOS(Real Time Operation System) as operation system. The system not only collects, processes and transmits monitoring data of power distribution and rectifying, but also intelligently manages battery based on Monitoring Module M500F these data. R48-2900 Rectifier Module Based on power system maintenance requirements, rectifying module adopts world-leading power and electronics technology and DSP technology with built-in advanced microprocessor, unique heat exchange design combining both natural cooling and forced cooling and soft switch technology AC Distribution Two 100A mains inputs in manual switchover mode As high as 40kA(8/20 s) lightning strike endurable Rectifying Module R48-2900 DC Distribution Load low voltage disconnection protection (optional) and battery low voltage disconnection protection; both fuse and MCB available for DC output protection Dimensions And Weight Model W D H(mm) Weight(Kg) PS48600-3/2900-X5 600 600 2000 162(Rectifier included) PS48400-3/2900-X5 600 600 1600 147(Rectifier included) DC Distribution 7 DC Power System Benefits z Reliable operation in rural environ- PS4875/25 Small System ments- where AC conditions are harsh z Easy to expand because of hot-swap rectifier modules z Wall-mount style saves room space PS4875/25 is wall mounted one cabinet system integrated with AC and DC distribution units, and can provide up to 75A for -48Vdc. This system is based upon HD4825-3 rectifier module, which offers high power density, high efficiency, and accurate load sharing between rectifier modules. Systems are monitored and controlled by PSM-A10 which offers RS232 and dry contact interface, and can connect with modem or PSNA card to realize remote monitoring PS4875/25 is optimized for fiber repeater station power applications. This system offers advanced features including intelligent battery monitoring, remote monitoring and low voltage disconnection. This is suitable choice for installation in region with poor AC regulation. In addition, there is AC surge protection provided in the AC distribution unit Applications PS4875/25 14 z Data Center z Small Telecom Exchanges z Amplifier Sites z Fiber Repeater Key Features z Providing up to 75A in one cabinet z Full current available to -58Vdc z Wide input voltage window and enhanced AC surge protection z Front access design for easy installation and maintenance z z Optional Priority load function to support critical load functions LCD display for alarm and components status z Optional remote monitor and control Business-Critical Continuity PSM-A10 Controller PSM-A10 is a microprocessor based monitoring and control unit that is used in PS4875/25 power system. This unit has been specifically developed to provide monitoring, management and indication for DC power system. LCD front display and keyboard provide the system operational condition, Monitoring Module PSM-A10 setting and control. RS232 provides connectivity for remote monitoring via modem or PSNA card, at the same time, dry contact can also provide remote alarms for system. Multi-level password access is provided for safety operation HD4825-3 Rectifier Module The rectifiers are rated 25A and deliver 1450W at 58Vdc. The rectifier has adaptation power limiting control mode to ensure sufficient output even when the input voltage is low. The rectifiers also have advanced short circuit feedback protection. When the output short circuits, the rectifier output current will feed back to a 1/3 rated current. The rectifier uses analog current sharing technology. When the monitoring module or a rectifier module fails, the other rectifiers will maintain the current sharing function. The rectifier has a built-in CPU for monitoring and controlling operation and for Rectifier Module HD4825-3 communicating with monitoring module AC Distribution The systems have one AC mains input which is 63A, 1 phase / 3 line system. At the same time, systems integrate with surge protection in AC distribution units DC Distribution DC distribution units can provide 2 battery fuses and LVD function. The output branches are equipped with short circuit and over current protection and branch capacity can be adjusted to requirements Dimensions And Weight Model PS4875/25 W 450 D H(mm) 260 700 Weight(Kg) 40(Rectifier included) 15 DC Power Systems for Business-Critical Continuity PS48300/1800 Integrative DC Power Series -48VDC up to 17.4kW Introduction PS48300/1800 system is optimized for base station power application. This system offers advanced features, DSP control technology, intelligent battery monitoring, remote monitoring and low voltage battery disconnection. The system comes fully equipped with integrated AC and DC distribution. Cost-effective for possible demand and future-proof, flexible and scalable system that can be configured to meet current demand and future expansion. Features Provide up to 17.4kW Max Front access design for installation and maintenance Wide input voltager range from 85Vac to 300Vac Wide working temperature:-40 +70 Work in poor electric power environment Rectifiers adopt DSP control technology, wtih high power density Low voltage battery disconnection to protect batteries Easily expandable with more power or/and feature when new demand arise Self-contained surge protection for AC,DC and signal Hot swap of rectifier and monitoring modules Utilize CE/UL approved rectifier R481800A PS48300/1800 System Electrical Specifications Nominal Input Votage Nominal Output Votage Input Votage Range Frequency Range Output Power(max) 380Vac/220Vac(3 phase/1 phase) -48Vdc 85-300Vac(Line-neutral), power decrease linearly below 176Vac 45 - 65Hz 17.4kW AC Distribution Input Output X1,X3 System 2 100A/3P (manual switchover) 1 16A/3P 3 16A/1P X2 System 1 63A/4P (Single input) None X6 System 1 63A/4P(Single input) 1 16A/3P,1 16A/1P DC distribution X1,X2,X3 System 2 250A 12 Output 5 100A(Fuse) 1 63A/1P(MCB) 2 63A/1P,2 32A/1P(MCB) 2 10A/1P(MCB) Battery Fuse DC Output LLVD BLVD Mechanical Parameters X1,X6 System X2,X3 System 600W 600W 600D 1600H(mm) 600D 2000H(mm) PS48300/1800-X2 PS48300/1800-X3 X6 System 2 250A 7 Output 3 100A (Fuse) 2 32A/1P (MCB) 2 10A/1P (MCB) 130kg (excluding rectifiers and SCU) 150kg (excluding rectifiers and SCU) PS48300/1800-X1 MCB MCB PS48300/1800 DC Power Systems for Business-Critical Continuity M500D Monitoring module Features Intelligent batterymanagement Visual and audible alarms Alarm history log RS232/Modem, User configurable digital inputs Hot Swapable and dry contacts M500D Monitoring Module R48-1800A Rectifier module General Safety EMC Dimensions Weight Enclosure Input characteristics Voltage Line frequency Power Factor Efficiency CE, UL UL/ EN/ IEC 60950-2000 EN 55022 Class B 87.9 85.3 272mm H W D 2.0kg IP 20 Specification 85 300 power decrease linearly below 176Vac 45 65 0.99 91 Output characteristics Voltage Power Current Load regulation Line regulation Load share Peak to peak noise Psophometric weighted noise THD Specification -42 -58 1740 0 33 0.5 0.1 0.9 100 2 5 Unit Vac Hz Remark Single phase R48-1800A Rectifier module % Unit Vdc W A % % A mV pk-pk mV % Environment conditions Operating temperature Storage temperature Relative humidity Elevation Remark Rectifier output power and input voltage relationship 30A@-58V Output power 100% (0 - 20 MHz) Specification -40 +70 (full power to +45 - 40 + 70 90% RH 2000 m 20% 0 85 300 Input voltage(V) 176 ) Output Current and Output voltage relationship Output voltage Protection characteristics Short circuit protection at constant current Output over-voltage protection, voltage set point selectable Input over-voltage protection, automatically recoverable Input under-voltage protection, automatically recoverable Over-temperature protection , > 98 protection, automatically recover Emerson Network Power. The global leader in enabling business-critical continuity. Emerson Network Power Co., Ltd. No. 1 Kefa Rd., Science & Industry Park Nanshan District 518057, Shenzhen, China Phone: +86-755-8601-0808 Fax: +86-755-8601-0909 www.emersonnetworkpower.com.cn www.emersonpower.com.cn 58 48.3 0 30 33 Output current (A) AC Power Embedded Computing Outside Plant Racks and Integrated Cabinets Connectivity Embedded Power Power Switching&Controls Services DC Power Monitoring Precision Cooling Surge Protection Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 2007 Emerson Electric Co. 2007.06 DC Power System Benefits z Reliable operation in rural environ- PS24600/75 Medium System ments- where AC conditions are harsh. z Easy to expand because of hot-swap rectifier modules PS24600/75 is one cabinet system integrated with AC and DC distribution units, and can provide up to 600A for +24 Vdc. This system is based upon HD2475-2 rectifier module, which offers high power density, high efficiency, and accurate load sharing between rectifier modules. Systems are monitored and controlled by PSM-A 11which offers RS232 and dry contact interface, and can connect with modem or PSNA card to realize remote monitoring PS24600/75 is optimized for common fixed line and mobile switch applications. This system offers advanced features including priority load function, intelligent battery monitoring, remote monitoring and low voltage disconnection. This is a suitable choice for installation in region with poor AC regulation. In addition, there is AC surge protection provided in the AC distribution unit Applications z Base Transceiver Stations( BTS) z Data Center Medium Telecom Exchanges z Key Features PS24600/75 16 z Providing up to 600A in one cabinet z Full current available to +24V z Wide input voltage window and enhanced AC surge protection z Front access design for easy installation and maintenance z Priority load function to support critical load functions z LCD display for alarm and components status z Optional remote monitor and control Business-Critical Continuity PSM-A11 Controller PSM-A11 is a microprocessor based monitoring and control unit that is used in PS24600/75 power system. This unit has been specifically developed to provide monitoring, management and indication for DC power system. LCD front display and keyboard provide the system operational condition, setting and control. RS232 provides connectivity for remote monitoring via modem or PSNA card, at the same time, dry contact can also provide remote alarms for system. Multi-level password access Monitoring Module PSM-A11 is provided for safety operation HD2475-2 Rectifier Module The rectifiers are rated 75A and deliver 2175W at 29Vdc The rectifier has adaptation power limiting control mode to ensure sufficient output even when the input voltage is low. The rectifiers also have advanced short circuit feedback protection. When the output short circuits, the rectifier output current will feed back to a 1/3 rated current. The rectifier uses analog current sharing technology. When the monitoring module or a rectifier module fails, the other rectifiers will maintain the current sharing function. The rectifier has a built-in CPU for monitoring and controlling operation and for communicating with monitoring module Rectifier Module HD2475-2 AC Distribution The systems have one AC mains input which is 63A, 3 phase / 5 line system. At the same time, systems integrate with surge protection in AC distribution units DC Distribution DC distribution units can provide 2 battery fuses and LVD function. The output branches are equipped with short circuit and over current protection and branch capacity can be adjusted to requirements Dimensions And Weight Model PS24600/75 W 600 D 600 H(mm) 2000 Weight(Kg) 225(Rectifier included) AC,DC Distribution 17 DC Power Systems for Business-Critical Continuity PS48120/1800 Integrative DC Power Series -48VDC up to 6.96kW Features Provide up to 6.96kW Max Front access design for installation and maintenance Wide input voltager range from 85Vac to 300Vac Wide working temperature of rectifier module:-40 +70 Work in poor electric power environment Rectifiers adopt DSP control technology, wtih high power density Low voltage battery disconnection to protect batteries Easily expandable with more power or/and feature when new demand arise Self-contained surge protection for AC,DC and signal Hot swap of rectifier and monitoring modules Utilize CE/UL approved rectifier R481800A DPC48-3 Introduction PS48120/1800 system is optimized for access, transmission, railway station, wireless base station power application. This system offers advanced features, DSP control technology, intelligent battery monitoring, remote monitoring and low voltage battery disconnection. The system comes fully equipped with integrated AC and DC distribution. Cost-effective for possible demand and future-proof, flexible and scalable system that can be configured to meet current demand and future expansion. DPC48-3 can be selected for 6V,12V,24V output. PS48120/1800 System Electrical Specifications Nominal Input Votage Nominal Output Votage Input Votage Frequency Range Output Power(max) 220Vac/1 phase -48Vdc 85V-300Vac , two-way input, switched manually (X1, X6 System) 125V-285Vac , two-way input, switched automatically (X2 System) 45 - 65Hz 6.96kW AC Distribution Input Rectifier MCB Output 2 63A/2P 4 16A/1P 1 16A/1P DC distribution Battery DC Output 7 Output DC/DC Converter DPC48-3 Input voltage range: Output voltage(Nominal): Output voltage range: Output power: X1,X2 System (None in X6 System) X2 System (None in X1, X6 System) Remark Fuse MCB FUSE 100A 2 1 63A/1P 2 32A/1P 1 10A/1P 1 100A NT00,1 50A NT00,1 6A NT00 43VDC-60VDC 24V,12V,6V 22-28.5V,11-14.2V,5.5-7.1V 6V 12V 0W 0W 30W 100W 60W 200W 24V 0W 100W 200W Notes: 1. 3 output voltage can be choosed discretionarily. 2. Only one output power can be choosed for each output voltage. Mechanical Parameters X1, X6 System X2 System PS48120/1800 600W 600D 2000H(mm) 600W 600D 2000H(mm) 110kg (excluding rectifiers and SCU) 120kg (excluding rectifiers and SCU) PS48120/1800 DC Power Systems for Business-Critical Continuity M500D Monitoring module Features Intelligent batterymanagement Visual and audible alarms Alarm history log RS232/Modem, User configurable digital inputs Hot Swapable and dry contacts M500D Monitoring Module R48-1800A Rectifier module General Safety EMC Dimensions Weight Enclosure Input characteristics Voltage Line frequency Power Factor Efficiency CE, UL UL/ EN/ IEC 60950-2000 EN 55022 Class B 87.9 85.3 272mm H W D 2.0kg IP 20 Range 85 300 45 65 0.99 91 Output characteristics Voltage Power Current Load regulation Line regulation Load share Peak to peak noise Psophometric weighted noise THD power decrease linearly below 176Vac Unit Vac Hz Comments Single phase R48-1800A Rectifier module % -42 -58 1740 0 33 0.5 0.1 0.9 100 2 5 Vdc W A % % A mV pk-pk mV % Rectifier output power and input voltage relationship 30A@-58V Output power 100% (0 - 20 MHz) 20% 0 85 Environment conditions Operating temperature Storage temperature Relative humidity Elevation -40 +70 - 40 + 70 90% RH 2000 m (full power to +45 300 Input voltage(V) 176 ) Output Current and Output voltage relationship Output voltage Protection characteristics Short circuit protection at constant current Output over-voltage protection, voltage set point selectable Input over-voltage protection, automatically recoverable Input under-voltage protection, automatically recoverable Over-temperature protection , > 98 protection, automatically recover Emerson Network Power. The global leader in enabling business-critical continuity. Emerson Network Power Co., Ltd. No. 1 Kefa Rd., Science & Industry Park Nanshan District 518057, Shenzhen, China Phone: +86-755-8601-0808 Fax: +86-755-8601-0909 www.emersonnetworkpower.com.cn www.emersonpower.com.cn 58 48.3 0 30 33 Output current (A) AC Power Embedded Computing Outside Plant Racks and Integrated Cabinets Connectivity Embedded Power Power Switching&Controls Services DC Power Monitoring Precision Cooling Surge Protection Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. 2007 Emerson Electric Co. 2007.06 DC Power System for Business-Critical Continuity PSC48150/25 DC-DC Power System +24Vdc/-48Vdc, 7.2kW PSC48150/25 DC-DC power system converts +24Vdc to -48Vdc for the telecom switches and base stations. The system adopts advanced high-frequency switch technology with excellent reliability and performance. Applications System Composition Model PSC48150/25 DC/DCModule C24/48-1200 2 6pcs DC-DC Converter Module Input Features Input voltage Max. input current Output Features Output DC voltage Output current Max. output power Rating power Alarm Functions Over/Under voltage in input/output Three independent dry-contact ports or DB9 port(for Huawei application only) Applicable to 24Vdc power systems in base stations, medium and small switches, satellite communications, data communications and electric power industry BTS +24Vcd BTS -48Vcd Features Wide DC input voltage range: 21V to 29V Hot-swappable DC-DC converter. Plug and play with on-line replacement of less than 1 min Extremely low radiation, meeting standard of EN300386 CLASS B Dry-contact output for alarm port, simple and universally-applicable Complete lightning proof in input and output rated at 5KA(8/20us) Complete fault protection functions Distribution Cabinet Distribution Cabinet 1pc DC/DC Converter 21 29Vdc 70A -52 -56Vdc 0 25A 1200W 89% PSC48150/25 DC-DC Power System DC Power System for Business-Critical Continuity Input Distribution Parameters Nominal Input Voltage Input voltage Input MCCB Indices +24Vdc 21 29Vdc 160A Output Distribution Parameters Output voltage range Max. output power Output routes Indices -52 -56Vdc 7200W MCB 100A 1 80A 1 32A 2 Mechanical Parameters Omponents DC-DC converter Cabinet Dimensions(H W 132.5 85.5 287 1460 200 400 Dmm) Weight 2.5kg 45kg Installation Dimensions 90 144.5 400 281.5 195.5 5- 17 100 200 Front Panel Of The Cabinet Cabinet Base Installation Dimensions Emerson Network Power. The global leader in enabling business-critical continuity. Emerson Network Power Co. No. 1 Kefa Rd ., Scie nce & Ind ustr y Park Nanshan District 518057, Shenzhen, China Phone: +86-755-8601-0808 Fax: +86-755-8601-0909 www.emersonnetworkpower.com.cn www.emersonpower.com.cn AC Power Systems Embedded Power Outside Plant Connectivity Inbound Power Precision Cooling DC Power Systems Integrated Cabinet Solutions Site Monitoring and Services 2006.4