CAPNOGRAPHY Simple connection sample lines allows the ET7 to be one of the industries lowest cost per patient End-tidal CO2 systems. Meditech Equipment Co., Ltd Nanjing Road No.100, Qingdao, Shandong Province, P. R. China Fax: 86-532-81705332 Tel: 86-532-85832673 81705331 sales@meditech.cn Technical Specification Carbon Dioxide Monitoring Mode of Sampling Principle of Operation: Initialization Time: Sidestream Non-dispersive infrared (NDIR) single beam optics, dual wavelength, no moving parts Capnogram displayed in less than 4 seconds, At an ambient temperature of 25° C, full specifications within 2 minutes CO2 Measurement Range: 0 to 152 mmHg, 0 to 20.0% 0 to 20 kPa (Barometric Pressure supplied by module and mmHg reading is auto-calculated ) CO2 Calculation Method: BTPS (Body Temperature Pressure Saturated) CO2 Response Time: <4 seconds - includes transport time and rise time CO2 Resolution: 0.1 mmHg 0 to 69 mmHg 0.25 mmHg 70 to- 152 mmHg± 2 mmHg CO2 Accuracy: 0 40 mmHg 41 - 150 mmHg ± 8% of reading Above 80 breath per minute ± 10% of reading * NOTE: Gas temperature at 25° C. CO2 Stability: Short /long Term Drift: Drift shall not exceed 1 mmHg maximum. Module will auto run zero calibration when drift exceed 1 mmHg. CO2 Noise: RMS noise of the module shall be less than or equal to 0.25 mmHg Sampling Rate: 100 Hz at 5% CO2 Respiration Rate Range: 2 to 150 breaths per minute (BPM) Respiration Rate ± 1 breath Accuracy: Calibration ETCO2 Calculation Method: No routine user calibration required. Peak of the expired CO2 waveform Inspired CO2 Measurement: Range: 3 to 50 mmHg Method: lowest reading of the CO2 waveform in the previous breath need compensations for: Expired O2, Balance gas (N2, N2O, He) and Anesthetic Agents Compensations for barometric pressure has been finished by module itself. Compensations: Environmental: Temperature and Humidity: Atmospheric Pressure: Operating: 0 to 50°C, 10 to 90% RH, non-condensing Storage: -40 to 60°C, 10 to 90% RH, non-condensing Storage: 400-800 mmHg Host System to ensure that the power supply conforms to applicable standards - Recommend IEC 60601-1 Type BF. Mode of operation: Model MD ET7 CO2 module is rated for continuous use. No marking is required. Category AP/APG: AP - This device is not suitable for use in the presence of a flammable anesthetic mixture with air or nitrous oxide Water Resistance: IPX4 - Splash-proof - Module only (When gas dryer line is inserted into the gas-in receptacle) Shock Impact: IEC TR 60721-4-7 Class 7M3 (designed to withstand environments subject to significant vibrations or high shock levels) EN60068-2-27 Shock EN60068-2-64 Random Vibration Radiated Host system dependent, designed to emissions: meet the requirements of EN55011 - CISPR 11 Class B 30 MHz to 1000 MHz Electrostatic Host system dependent, designed to discharge meet the Immunity: requirements of IEC 61000-4-2 (200104) 6 kV conducted 8 kV air discharge Radiated Host system dependent, designed to immunity: meet the requirements of IEC 61000-4-3 (200203) 80 MHz to 2.5 GHz, 20 V/m Immunity to Host system dependent, designed to conducted meet the Disturbances induced requirements of by RF fields: IEC 61000-4-6 (2001-04) Protection against electric shock: The module does not provide electrical isolation for enclosure leakage current, patient risk circuit, or patient auxiliary current. Physical Characteristics and Host Interface: Physical: Module weight is less than 186g Module characteristics: Size: <76mm(wide) *38mm(high)* 108mm(deep) length – 48.88 cm (unless otherwise Data Interface: Cable RS-232, bi-directional, 19200 baud, standard specified)N-8-1 Module Standard- Lemo Redel 8-pin plastic, Interconnection: Material PSU Module Plug: PAB.M0.8GL.AC39GZ Bend Relief: GMA.1B.030.DA Host Receptacle: PKB.M0.8GL.LA Custom configurations available upon request. Pinout: 1. VA 5.0V 2. SHIELD Shield return 3. DGND Digital return 4. VSRC 5.0V 5. TxD Serial data from MD ET7 6. RxD Serial data from Host 7. AGND Analog return 8. NC Model MD ET7 The MD ET7 Module relies solely on the CO2 host system for power. The host system shall provide the following: module Voltage VA:+5.00 VDC 5.0%; requirements: 70 mA (350 mW)typ (Steady-state); 240 mA (1.2 W) max (Offset calibration ). Ripple not to exceed 50.0 mV VSRC: DC Output Voltage:+5 V Output Current: 40 mA . calibration:<1.1W Power Rating: Total System Power: Offset Power interface must Steady-state < 0.5 W conform to IEC 60601-1 Accessories Sampling Line Gas Dryer Nasal Tube Airway Adapter