www.comoso.com Electronic safety sensor accessories SD-I-U- … Technical data Operating voltage: Fuse rating: Operating current at 24 VDC: Operating temperature range: Storage temperature range: Climatic stress: Protection class: Mounting location: 24 VDC −15 %/+20 % (stabilised PELV) external fuse 1 A slow-blow max. 500 mA, internally protected 0 … 55 °C, in case of vertical positioning −25 °C … +70 °C relative humidity 30 % … 85 %, non-condensing IP20 earthed lockable control cabinet with at least IP54 protection class if fitted between two lateral clamping blocks on the rail 10 … 57 Hz / 0.35 mm and 57 … 150 Hz / 5 g Resistance to vibrations: • UNIVERSAL-Gateway for the series-wiring of the diagnostic signals from safety switching components with integrated SD interface. Comprehensive status and diagnostic data from the SD components are transmitted to the control system through the field bus interface. • Diagnostic lines of max. 31 safety switching components can be wired in series • Series-wiring of different components enabled (CSS 34, RSS 36, AZM 200, MZM 100 etc.) • Reduced wiring expenditure through the series-wiring of the safety channels and the diagnostic lines in the field • Automatic addressing of the safety switching components in the SD interface • IP20 component for quick-fix mounting onto standard DIN rails in the control cabinet to IEC 60068-2-6 Restistance to shock to IEC 60068-2-29: 10 g EMC rating: to EN 61000-4-2 (ESD) ±6 kV contact discharge / ±8 kV Air discharge to EN 61000-4-3 (HF field) 10 V/m / 80 % AM to EN 61000-4-4 (Burst) ±1 kV all connections to EN 61000-4-5 (Surge) ±1 kV all connections to EN 61000-4-6 (HF cables) 10 V all connections EMC interfering radiation: to EN 61000-6-4 (2002) industrial interfering radiation Rated insulation voltage Ui: 32 V Rated impulse withstand voltage Uimp: 0.5 kV Overvoltage category:II Degree of pollution:2 Dimensions (W x H x D): 50 x 100 x 80 mm (= mounting height starting from rail) Available FIELD BUS interfaces: • PROFINET IO • EtherNet IP • DeviceNet • CC-Link • CANopen • Modbus/TCP Approvals Ordering details SD-I-U-➀ No. Option Wiring diagram Description PN PROFINET IO EIP DN CCL CAN MT EtherNet IP DeviceNet CC-Link CANopen Modbus/TCP Sensor Sensor Sensor ➀ X1 (IN) X2 (IN) SD-OUT Y1 (OUT) X1 (IN) Y2 (OUT) SD-IN X2 (IN) SD-OUT Y1 (OUT) X1 (IN) Y2 (OUT) SD-IN X2 (IN) SD-OUT Y1 (OUT) Y2 (OUT) SD-IN Legend ➀ Safety monitoring module ➁ Gateway SD ➂ Fieldbus ➃ PLC with fieldbus interface For more information, see our online product catalog: www.usa.schmersal.net ➀ ➁ ➂ ➃ 1-91 www.comoso.com Electronic safety sensor accessories T-adapter CSS-T Terminal connector Technical data 4 45° 5 2 1 4 4 ¤16,4 3 1 7 86 23,5 45° 2 5 1 42,9±0,5 M12 x 1 ¤15 ¤15 56 2345 3 1 2 3 Rated operating voltage of the SD devices to be connected: Rated operating current of the SD devices to be connected: Fuse of the connecting cables (circuit breaker): Ambient temperature Tu: 24 V (–15%/+10%) 0.6 A 2A −25 °C … +70 °C CSS / RSS 1 2 3 4 5 6 7 8 A1 X1 A2 (GND) X2 SD-OUT 1 2 3 4 5 1 2 3 4 5 to safety controller • Enables the series-wiring of safety sensors. To this end, both the safety channels and the serial diagnostic cable are wired in series. • For the wiring, M12 cable extensions can be used. The voltage drop (due to the cable length, cable section, voltage drop per sensor) should be taken into account, as it reduces the maximum number of safety sensors that can be wired in series. •S upplies the safety channels with operating voltage Approvals Approvals Ordering details Ordering details T-adapterCSS-T Wiring diagram Terminal connectorCSS-T-A CSS-T-A 1-92 For more information, see our online product catalog: www.usa.schmersal.net CSS-14-34-S-SD-M-ST Sensor chain A1 Y1 A2 (GND) Y2 SD-IN CSS-14-34-S-SD-M-ST A1 X1 A2 (GND) X2 SD-OUT CSS-14-34-S-SD-M-ST 1 2 3 4 5 CSS-T CSS-T CSS-T www.comoso.com Electronic safety sensor accessories Terminal connector Technical data 54,5 2 38 16,5 1 43 X1 X2 SD-OUT SD-IN A1 (+24V) A1 (+24V) A2 (GND) A2 (GND) 5 6 7 8 1 2 3 4 • Enables the series-wiring of sensors and solenoid interlocks with SD interface. To that effect, both the safety channels and the serial diagnostic lines are wired in series. • For the wiring, M12 cable extensions can be used. The voltage drop (due to the cable length, cable section, voltage drop per sensor) should be taken into account, as it reduces the maximum number of safety sensors and interlocks with SD interface that can be wired in series. • Supplies the safety channels with operating voltage • Leads the SD interface back to the control cabinet to connect further SD participants of other safety circuits Approvals Approvals Ordering details Ordering details Y-adapterCSS-Y-8P Wiring diagram Terminal connectorCSS-Y-A-8P 2 Connection cables M12, 8-poles With 0.5m cable101217786 With 1m cable101217787 With 1.5m cable101217788 With 2.5m cable101217789 With 5m cable101217790 CSS-Y-8P For more information, see our online product catalog: www.usa.schmersal.net 1 Y1 Y2 SD-IN SD-OUT A1 (+24V) A1 (+24V) A2 (GND) A2 (GND) X1 X2 SD-OUT SD-IN A1 (+24V) A1 (+24V) A2 (GND) A2 (GND) 2 5 6 7 ➁ 81 2 3 4 5 6 7 8 1 2 3 4 CSS-14-34-S-SD-M-ST X1 X2 SD-OUT A2 (GND) A1 (+24V) SD-IN Y2 Y1 1 2 6 5 ➀ 31 8 7 4 Rated operating voltage of the SD devices: 24 VDC (−15%/+10%) Rated operating voltage of the adapter: 30 VDC Max. operating current of the device to be connected: 1A Fuse of the connecting cables (circuit breaker): 4A Ambient temperature Tu: −25 °C … +75 °C CSS-14-34-S-SD-M-ST Y-adapter CSS-Y-8P CSS-Y-8P 1-93