1-91 Electronic safety sensor accessories SD-I-U

advertisement
www.comoso.com
Electronic safety sensor accessories
SD-I-U- …
Technical data
Operating voltage:
Fuse rating:
Operating current at 24 VDC:
Operating temperature range:
Storage temperature range:
Climatic stress:
Protection class:
Mounting location:
24 VDC −15 %/+20 % (stabilised PELV)
external fuse 1 A slow-blow
max. 500 mA, internally protected
0 … 55 °C, in case of vertical positioning
−25 °C … +70 °C
relative humidity 30 % … 85 %, non-condensing
IP20
earthed lockable control cabinet
with at least IP54 protection class
if fitted between two lateral
clamping blocks on the rail
10 … 57 Hz / 0.35 mm
and 57 … 150 Hz / 5 g
Resistance to vibrations:
• UNIVERSAL-Gateway for the series-wiring
of the diagnostic signals from safety switching
components with integrated SD interface.
Comprehensive status and diagnostic data
from the SD components are transmitted
to the control system through the field bus
interface.
• Diagnostic lines of max. 31 safety switching
components can be wired in series
• Series-wiring of different components enabled
(CSS 34, RSS 36, AZM 200, MZM 100 etc.)
• Reduced wiring expenditure through the
series-wiring of the safety channels and the
diagnostic lines in the field
• Automatic addressing of the safety switching
components in the SD interface
• IP20 component for quick-fix mounting onto
standard DIN rails in the control cabinet
to IEC 60068-2-6
Restistance to shock
to IEC 60068-2-29:
10 g
EMC rating:
to EN 61000-4-2 (ESD) ±6 kV contact discharge / ±8 kV Air discharge
to EN 61000-4-3 (HF field)
10 V/m / 80 % AM
to EN 61000-4-4 (Burst) ±1 kV all connections
to EN 61000-4-5 (Surge) ±1 kV all connections
to EN 61000-4-6 (HF cables)
10 V all connections
EMC interfering radiation:
to EN 61000-6-4 (2002)
industrial interfering radiation
Rated insulation voltage Ui:
32 V
Rated impulse withstand voltage Uimp:
0.5 kV
Overvoltage category:II
Degree of pollution:2
Dimensions (W x H x D):
50 x 100 x 80 mm
(= mounting height starting from rail)
Available FIELD BUS interfaces:
• PROFINET IO
• EtherNet IP
• DeviceNet
• CC-Link
• CANopen
• Modbus/TCP
Approvals
Ordering details
SD-I-U-➀
No. Option
Wiring diagram
Description
PN
PROFINET IO
EIP
DN
CCL
CAN
MT
EtherNet IP
DeviceNet
CC-Link
CANopen
Modbus/TCP
Sensor
Sensor
Sensor
➀
X1 (IN)
X2 (IN)
SD-OUT
Y1 (OUT) X1 (IN)
Y2 (OUT)
SD-IN
X2 (IN)
SD-OUT
Y1 (OUT) X1 (IN)
Y2 (OUT)
SD-IN
X2 (IN)
SD-OUT
Y1 (OUT)
Y2 (OUT)
SD-IN
Legend
➀ Safety monitoring module
➁ Gateway SD
➂ Fieldbus
➃ PLC with fieldbus interface
For more information, see our online product catalog: www.usa.schmersal.net
➀
➁
➂
➃
1-91
www.comoso.com
Electronic safety sensor accessories
T-adapter CSS-T
Terminal connector
Technical data
4
45°
5 2
1
4
4
¤16,4
3
1 7 86
23,5
45°
2
5
1
42,9±0,5
M12 x 1
¤15
¤15
56
2345
3
1
2
3
Rated operating voltage of the SD devices to be connected:
Rated operating current of the SD devices to be connected:
Fuse of the connecting cables (circuit breaker):
Ambient temperature Tu:
24 V (–15%/+10%)
0.6 A
2A
−25 °C … +70 °C
CSS / RSS
1 2 3 4 5 6 7 8
A1
X1
A2 (GND)
X2
SD-OUT
1
2
3
4
5
1
2
3
4
5
to safety controller
• Enables the series-wiring of safety sensors.
To this end, both the safety channels and the
serial diagnostic cable are wired in series.
• For the wiring, M12 cable extensions can
be used. The voltage drop (due to the cable
length, cable section, voltage drop per sensor) should be taken into account, as it reduces the maximum number of safety sensors
that can be wired in series.
•S
upplies the safety channels with operating
voltage
Approvals
Approvals
Ordering details
Ordering details
T-adapterCSS-T
Wiring diagram
Terminal connectorCSS-T-A
CSS-T-A
1-92
For more information, see our online product catalog: www.usa.schmersal.net
CSS-14-34-S-SD-M-ST
Sensor chain
A1
Y1
A2 (GND)
Y2
SD-IN
CSS-14-34-S-SD-M-ST
A1
X1
A2 (GND)
X2
SD-OUT
CSS-14-34-S-SD-M-ST
1
2
3
4
5
CSS-T
CSS-T
CSS-T
www.comoso.com
Electronic safety sensor accessories
Terminal connector
Technical data
54,5
2
38
16,5
1
43
X1
X2
SD-OUT
SD-IN
A1 (+24V)
A1 (+24V)
A2 (GND)
A2 (GND)
5
6
7
8
1
2
3
4
• Enables the series-wiring of sensors and
solenoid interlocks with SD interface. To that
effect, both the safety channels and the serial
diagnostic lines are wired in series.
• For the wiring, M12 cable extensions can
be used. The voltage drop (due to the cable
length, cable section, voltage drop per
sensor) should be taken into account, as it
reduces the maximum number of safety sensors and interlocks with SD interface that can
be wired in series.
• Supplies the safety channels with operating
voltage
• Leads the SD interface back to the control
cabinet to connect further SD participants of
other safety circuits
Approvals
Approvals
Ordering details
Ordering details
Y-adapterCSS-Y-8P
Wiring diagram
Terminal connectorCSS-Y-A-8P
2
Connection cables
M12, 8-poles
With 0.5m cable101217786
With 1m cable101217787
With 1.5m cable101217788
With 2.5m cable101217789
With 5m cable101217790
CSS-Y-8P
For more information, see our online product catalog: www.usa.schmersal.net
1
Y1
Y2
SD-IN
SD-OUT
A1 (+24V)
A1 (+24V)
A2 (GND)
A2 (GND)
X1
X2
SD-OUT
SD-IN
A1 (+24V)
A1 (+24V)
A2 (GND)
A2 (GND)
2
5
6
7
➁ 81
2
3
4
5
6
7
8
1
2
3
4
CSS-14-34-S-SD-M-ST
X1
X2
SD-OUT
A2 (GND)
A1 (+24V)
SD-IN
Y2
Y1
1
2
6
5
➀ 31
8
7
4
Rated operating voltage of the SD devices:
24 VDC (−15%/+10%)
Rated operating voltage
of the adapter:
30 VDC
Max. operating current of the device to be connected:
1A
Fuse of the connecting cables (circuit breaker):
4A
Ambient temperature Tu:
−25 °C … +75 °C
CSS-14-34-S-SD-M-ST
Y-adapter CSS-Y-8P
CSS-Y-8P
1-93