Advanced Illumination Power Connection Options

advertisement
Ai Power Connection Options
ground
+
12 & 24 Volt lights are built with flying leads
and have load limiting resistors for use with any
regulated 24 volt DC power source.
-
24v
-
+
+
Older 24v models use
white/black wiring.
ground
Inline Current Source built into the power cable.
gate -
iCS
gate +
Requires 24v power source
ground
+
-
click for wiring info
Strobe Control built into the power cable.
gate +
iSU
gate trigger mode select
Available only with
24v, iCS, and iSU wiring
M12 Add-on
C2 *
Requires 24v power source
For Use With:
CS100, CS100-IC,
CS300, CS300-IC,
CS410, CS420,
MS210, MS220
S4000, S6000, S6000-AS
click for wiring info
click for M12 pinout
click for C2 pinout
For Use With:
Pulsar 710
C3*
click to view manual
For Use With:
Pulsar 320
C5*
click to view manual
Standard cable length: 1.5 Meter (59”)
* REMOVING THE CONNECTOR VOIDS Ai’s WARRANTY
a d v a n c e d i l l u m i n a t i o n .c o m
ICS SPECIFICATIONS
Parameter
Specification
Input Voltage Range
+21 to 30 volts dc (24V nom)
Maximum Input Current
2.0 A
Gating Control
Active High (GHI) and
Active Low
GHI Turn On Voltage = 4.2v / Input
Tolerant to -10 to +24 vdc
Analog 0-10V: White 0V =0%,
10V=100%.
Gating Time
30µs +/- 10µs
Storage Temperature
-40 to +125C
Operating Temperature
0 to +70C
Housing Material
High Impact Polycarbonate
Weight
Approx 1.7 oz (cable not included)
Size
Approx 3.74L x 0.76W x 0.76H (in.)
Wash Down Version
Note: Can also be used as an active LOW
gate input
Approx 5.06L x 0.76W x 0.76H (in.)
ICS PINOUT
COLOR
FUNCTION
BROWN
Vin (+)
BLUE
GND (-)
WHITE
CTRL
BLACK
GATE
GRAY
Chassis GND
ICS CONNECTION DIAGRAM
a d v a n c e d i l l u m i n a t i o n .c o m
iCS WIRING DIAGRAMS
STANDARD OPERATION
LIGHT IS ALWAYS ON
BROWN
+24VDC
BLUE
WHITE
GND
ACTIVE LOW GATE
LOW TRIGGER SHUTS LIGHT OFF
BLACK
BROWN
+24VDC
BLUE
4.7K
0-10V ANALOG CONTROL
LINEAR OUTPUT ADJUST
GND
BROWN
WHITE
BLACK
TRIGGER
+24VDC
NPN
BLUE
GND
GND
WHITE
0-10V ADJUST.
BLACK
ACTIVE HIGH GATE
HIGH TRIGGER SHUTS LIGHT OFF
GND
BROWN
+24VDC
0-10V ANALOG CONTROL
LINEAR OUTPUT ADJUST WITH EXTERNAL POTENTIOMETER
GND
BROWN
+24VDC
GND
0-10V ADJUST.
GND
WHITE
BLACK
TRIGGER
PNP
BLUE
5K
BLUE
4.7K
WHITE
GND
BLACK
Wiring Diagram for Optional Manual Intensity Control
Note: The MP-iCS is
compatible only with
lights built with the
IC wiring option after
3/1/2012. It cannot be
used with 24v lights, or
the iCS 1.0
8 0 2 .7 6 7 .3 8 3 0
click to view MP-iCS Spec Sheet
ISU SPECIFICATIONS
Specification
Parameter
Notes
Input Voltage Range
+18 to 30 VDC
24V nominal
Strobe output
0 - 12A*
* Pulse-width/Light head dependent
Max. Repetition Rate
100 Hz **
** Light head dependent
Current Output Adj.
Min to Max Current adj. as
established by factory setting
Maximum current set
assuming 300µSec operation
Max. Input Current
1.1A
Approx 100mA local
Active HI: WHITE
Active LO: BLACK
TTL compatible, 30VDC tolerant
Select wire that is used to
put the unit into Standard or
Bypass triggering mode
- Pulled 0 for bypass
- Unconnected for standard
Active HI: WHITE
Active LO: BLACK
Trigger
Mode Select
Mechanical & Environmental
Power Indicator
Red LED is used to indicate
power is being supplied
Storage Temperature
-40 to +125C
Operating Temperature
0 to +70C
Housing Material
High Impact Polycarbonate
Weight
Approx 1.7 oz
Size
Approx 4.55L x 0.67W x 0.70H Inches
Cable Not Included
ISU PINOUT
BROWN
VIN +
BLUE
VIN -
WHITE
Active high trigger input
BLACK
Active low trigger input
GRAY
Trigger Mode Select: Connect to 0V to enable timing bypass.
Leave floating for fixed trigger mode
ISU TRIGGER MODES
FIXED TRIGGER MODE
TRIGGER IN
TIMING BYPASS TRIGGER MODE
TRIGGER IN
T1 T2
T1 T2 T3
T3
LED PULSE OUT
T1 = TRIGGER WIDTH
T2 = 10µSec
T3 = FIXED BY USER POTENTIOMETER
LED PULSE OUT
T1 = TRIGGER WIDTH
T2 = 10µSec
T3 = PULSE WIDTH*
T1 = T3
* MAX PULSE WIDTH WILL NOT EXCEED
FIXED SETTING ON POTENTIOMETER
a d v a n c e d i l l u m i n a t i o n .c o m
ISU WIRING
Sourcing Output
Sinking Output
Triggered When White is High
Triggered When Black is Low
NPN Sourcing
NPN Sinking
NPN Sourcing - Common (V+)
PNP Sourcing
PNP Sinking
IMPORTANT NOTES:
- FOR BEST RESULTS, AVOID RUNNING THE CABLE NEAR HIGH
NOISE ENVIRONMENTS
- THE TRIGGER SOURCE AND ISU MUST SHARE A COMMON
GROUND FOR REPEATABLE LIGHTING
- TIE THE BARE DRAIN WIRE OF THE ISU TO A CHASSIS GROUND
OR EARTH GROUND; IF ONE IS NOT AVAILABLE, TIE TO -24V
* OPTIONAL: TIE GRAY TO -24V (BLUE) FOR TIMING BYPASS
SELECTION; OUTPUT PULSE WIDTH WILL MATCH THE INPUT
TRIGGER WIDTH
** ALL RESISTORS SHOWN ARE INTERNAL TO THE ISU. NO
EXTERNAL RESISTORS ARE NEEDED
8 0 2 .7 6 7 .3 8 3 0
M12 Connector Pin-Out
Male end view. Ai lights are built with the male connector standard.
24 Volt
4
4 Pin
3
1
2
PIN
COLOR
DESC.
1
2
3
4
BROWN
WHITE
BLUE
BLACK
+24V IN
Not Used
-24V IN
Not Used
PIN
COLOR
DESC.
1
2
3
4
BROWN
WHITE
BLUE
BLACK
+24V IN
GHI
-24V IN
GLO
PIN
COLOR
DESC.
1
2
3
4
5
BROWN
WHITE
BLUE
BLACK
GRAY
ICS
4 Pin
4
3
1
2
ISU
5 Pin
4
5
3
1
2
+24V IN
TRIGGER IN, ACTIVE HIGH
-24V IN
TRIGGER IN, ACTIVE LO
TRIGGER MODE SELECT
Dimensional Information
39.3
(1.55)
Ø 14.5
(.57)
M12x1
d n
v ac ne cdei dl li ul lm
u m
c omm
a d va a
i ni an ta it oi on n. c. o
C2 Connector Pin-out
Male - Solder Side
Pin 7 (negative)
Channel 0
Orange
Pin 6 (reserved)
ID 2
Pin 3 (negative)
Channel 1
Red
Pin 5 (negative)
Channel 2
Blue
Pin 1 (positive)
White
Pin 4 (reserved)
ID 1
Pin 2 (negative)
Channel 3
Green
8 0 2 .7 6 7 .3 8 3 0