DIMENSIONAL DRAWING: 5501L/LT

advertisement
DIMENSIONAL DRAWING: 5501L/LT
92.9
[3.66]
1266.8
[49.87]
LIGHT SENSOR
(OPTICAL MODEL)
25.5
[1.00]
LIGHT SENSOR
(IR MODEL)
5501LT IR = 48.2
[1.9 ]
OPTICAL = 43.8
[1.72 ]
38.9
[1.53]
600
[23.62]
VESA MOUNT PER MIS-F 600,600,
6MM, MAX SCREW DEPTH = 10MM
1209.6
[47.62]
DISPLAY ACTIVE AREA
1213
[47.8]
BEZEL OPEN AREA
683.6
[26.9]
BEZEL OPEN AREA
737.4
[29.03]
600
[23.62]
680.4
[26.8]
DISPLAY ACTIVE AREA
CABLE SECURITY COVER
SEE DETAIL B
DETAIL B
SCALE 0.500
AUDIO LINE IN
AC POWER IN
HEADPHONE OUT
REMOTE OSD
DISPLAYPORT IN
TOUCH USB
VGA IN
HDMI IN
COMPUTER MODULE (OPTIONAL)
CABLE SECURITY COVER (INCLUDED WITH COMPUTER MODULE KIT)
REMOTE OSD (1 INCLUDED WITH TOUCHMONITOR)
P/N E483757
DIMENSIONS ARE IN MILLIMETERS [INCHES]
MS601483
DATE: 10/01/2015
REV: C
DIMENSIONAL DRAWING: 5501L/LT
MOUNTING INTERFACE FOR PERIPHERALS
ONE PER SIDE (FOUR TOTAL)
SEE DETAIL A
M3 THREADS, X2
20.5
[.8]
129
[5.08]
PEEL OFF COVERS TO ACCESS
PERIPHERAL MOUNTING SCREW
HOLES AND POWER CABLE.
DETAIL A
SCALE 1.000
DIMENSIONS ARE IN MILLIMETERS [INCHES]
MS601483
DATE: 10/01/2015
REV: C
DIMENSIONAL DRAWING: 5501L/LT
THERMAL RECOMMENDATIONS
PORTRAIT AND LANDSCAPE ORIENTATION
FLUSH MOUNTING
WALL MOUNTING
MAINTAIN AMBIENT ROOM TEMPERATURE
BELOW 40C
AIRFLOW DIRECTION
AIR BEHIND MONITOR MUST NEVER EXCEED
40C DURING OPERATION. INSTALL VENTING
AND/OR FANSIN WALL STRUCTURE TO CIRCULATE
AIR AND MAINTAIN SAFE OPERATING TEMPERATURE.
PRODUCT VENTING LOCATIONS
DO NOT BLOCK DURING OPERATION
WALL STRUCTURE
TOUCHMONITOR
TOUCHMONITOR
WALL STRUCTURE
AIRFLOW DIRECTION
DIMENSIONS ARE IN MILLIMETERS
MS601483
DATE: 10/01/2015
REV: C
DIMENSIONAL DRAWING: 5501L/LT
THERMAL RECOMMENDATIONS
TABLE-TOP ORIENTATION
PRODUCT VENTING ALL AROUND MONITOR
MUST BE KEPT OPEN DURING OPERATION
TO MAINTAIN SAFE OPERATING TEMPERATURE
WHEN MOUNTED IN TABLE-TOP ORIENTATION, DO NOT ALLOW
AIR TEMPERATURE BELOW MONITOR TO EXCEED OPERATING TEMPERATURE SPECIFICATIONS.
RECOMMENDATION: INSTALL AIR CIRCULATION DEVICES ABLE TO MONITOR AND CONTROL
AIRSPACE TEMPERATURE UNDER THE TOUCHMONITOR SO IT WILL COMPLY WITH
OPERATING TEMPERATURE SPECIFICATIONS
DIMENSIONS ARE IN MILLIMETERS
MS601483
DATE: 10/01/2015
REV: C
DIMENSIONAL DRAWING: 5501L/LT
OPTIONAL WALLMOUNT KIT
P/N E248743
609.6
[24.0]
DISTANCE OFF OF WALL AFTER MOUNTING
IR = 94.1
[3.7 ]
OPTICAL = 89.7
[3.5 ]
406.4
[16.0]
60
[2.4]
443.9
[17.5]
50
[2.0]
MONITOR OUTLINE
LANDSCAPE ORIENTATION
310.4
[12.2]
646
[25.4]
310.4
[12.2]
48.9
[1.9]
45.7
[1.8]
45.7
[1.8]
646
[25.4]
MONITOR OUTLINE
PORTRAIT ORIENTATION
313.6
[12.3]
413.9
[16.3]
413.9
[16.3]
54.7
[2.2]
319.4
[12.6]
DIMENSIONS ARE IN MILLIMETERS [INCHES]
628
[24.7]
319.4
[12.6]
54.7
[2.2]
628
[24.7]
54.7
[2.2]
319.4
[12.6]
MS601483
DATE: 10/01/2015
REV: C
DIMENSIONAL DRAWING: 5501L/LT
OPTIONAL RFID KIT P/N E031451
7.28
[.29]
DISTANCE ABOVE BEZEL
ANTENNA LOCATION
DIMENSIONS ARE IN MILLIMETERS
633.4
[24.94]
RECOMMENDED PLACEMENT ON BOTTOM SIDE
MS601483
DATE: 10/01/2015
REV: C
Download