CR360ML2 Mechanically Held Lighting Contactors

advertisement
GE Lighting Contactors
CR360ML2 Mechanically Held Lighting Contactors
600 Volts Maximum
50/60 Hertz 20 Amperes Continuous
GE Fastrac™ Program items are printed in red type.
Ordering Directions
Order by complete catalog number. Select number of poles and enclosure from Table O, select coil voltage from Table CD, for
additionally modified forms, use Tables O, O, O, and 0. Minimum catalog number is 10 digits.
_ Poles and Enclosure
Aux. Contacts Ctl. Module and Volts Pilot Devices Control Power
CR360ML2
O
<D
|
O
O
O
0
Voltage
Minimum complete catalog # 10 digits through enclosure.
List Price, GO-10MB
+o
$
+ <E>
+0
$0.00
Example: 20-Amp mechanically held lighting contactor with 6 NO poles in a Type 1 enclosure with
120 V separate control 1 NO/1 NC auxiliary contact and red on pilot light.
CR360ML2
List Price, GO-10MB
6NO Poles, Type 1 Enclosure +
120V Coil
+
1 NO/1 NC Auxiliary
No Control Module
Red Indicating Light
+
No Fuses or CRT
$
$
$
$
$
+©
+o
+0
Total
O Select Pole Configuration and Enclosure
Pole Configuration
Open
NC
NO
0
0
0
0
0
0
0
2
3
2
3
4
6
8
10
12
2
3
4
6
4
6
List Price,
GO-10MB
Cat. No.
Digits
CR360ML2
List Price,
GO-10MB
o • .
$287.00
305.00
318.00
492.00
548.00
609.00
701.00
340.00
514.00
570.00
723.00
02* G
03*G
04*G
06*G
08*G
10*G
12*G
22*G
33-G
44*G
,,., • i
$305.00
323.00
336.00
552.00
608.00
669.00
761 .00
358.00
574.00
630.00
783.00
08"A
10*A
12*A
22*A
33*A
44*A
66*A
552.00
66.00
0.00
202.00
0.00
820.00
Type 12
Type 1
Cat. No
Digits
CR360ML2
03*A
04*A
06*A
$
$
$
$
$
$
Cat. No.
Digits
CR360ML2
02*D
03* D
04*D
06*D
08*D
10*D
12*D
22*D
33*D
44*D
66* D
Type 3R
List Price,
GO-10MB
$395.00
413.00
426.00
642.00
698.00
759.00
851.00
448.00
664.00
720.00
873.00
Cat. No,
Digits
CR360ML2
List Price,
GO-10MB
$395.00
413.00
426.00
642.00
698.00
759.00
851.00
448.00
664.00
720.00
873.00
02* R
03*R
04* R
06* R
08* R
10*R
12*R
22* R
33* R
44*R
66* R
* Insert voltage from Table (D; if no additional modifications, 10-digit catalog number is complete.
<D Select Input Coil Voltage
o Se|ect
Without CPT
Contactor
Voltage
With CPT
Cat. No.
Line VoltageControl Voltage
Cat. No,
Digit
220-240 V 60 Hz— 1 20 V 60 Hz
B
Digit
120V60HZ
K
277V 60 Hz
440-480V60HZ — 120V60HZ
c
208V60HZ— 120V60HZ
D
2 7 7 V 6 0 H Z — 120V60HZ
K
Auxiliary Contacts
Auxiliary
Contacts
Cat. No.
List Price,
GO-10MB
Digit
None
A
—
1 NO and 1 NC (SPOT)
B
$ 66.00
2 NO and 2 NC (DPDT) CD
C
132.00
© Not available with pilot light option.
O Select Control Module and Module Voltage
120 Volts
Control Module
Cat. No.
Digits
24 Vac/dc
277 Volts
List Price,
GO-10MB
Cat, No.
Digits
List Price,
GO-10MB
Cat. No.
Digits
List Price,
GO-10MB
None
AA
—
AA
—
On/Off Control
11
$430.00
12
$430.00
13
$430.00
2-Wire Control®
21
382.00
22
382.00
23
382.00
3- Wire Control®
31
409.00
32
409.00
33
409.00
® Not available with push button control.
O Select Control
Power Option
® Not available with selector switch.
O Select Pilot Devices—Indicating Lights
No Indicating Light
Push Button or
Selector Switch
Cat. No.
Digit
List Price,
GO-10MB
None
A
—
Cat. No.
Red On
Indicating Light
Cat. No
Green Off
Indicating Light
Red On/Green Off
Indicating Light
List Price,
GO-10MB
Cat. No.
Digit
List Price,
GO-10MB
Cat. No.
Digit
Digit
List Price,
GO-10MB
H
$202.00
S
$202.00
M
$404.00
HOA Selector Switch
C
165.00
B
367.00
N
367.00
J
569.00
On/Off Selector Switch
E
165.00
D
367.00
P
367.00
K
569.00
On/Off Push Button
G
248.00
F
450.00
R
450.00
L
652.00
6-6
1999 Issue
Digit
List Price,
GO-10MB
Standard
A
—
Fused Control
Circuit
D
$165.00
1 50 VA CPT with
1 Secondary Fuse
S
202.00
1 50 VA CPT with
2 Primary and
1 Secondary Fuse
T
367.00
Prices ami data subject to change without notice
Gf Lighting Contactors
CH360ML2 Mechanically Held Lighting Contactors
600 Volts Maximum 50/60 Hertz
20 Amperes Maximum
GE FASTRAC™ Program items are printed in red type.
Maximum AC Voltage and Amp Ratings for
Main Contacts (Open or Closed)
Po es
Load Type
Amperes
Continuous
1 for 1 Phase
2 for 1 Phase
3 for 3 Phase
Tungsten
20
250 Vac
250 Vac
Ballast
20
347 Vac
600 Vac
General
30
347 Vac
600 Vac
Maximum DC Voltage and Amp Ratings for
Main Contacts (Open or Closed)
Poles t o Load
Load Type
Amperes
Continuous
2 in Series
3 in Series
General
20
125Vdc
250 Vdc
Withstand Current Ratings for Contactor
Typical CR360ML2 Contactor
Available Symmetrical Amperes rms
Application
The new CR360ML2 mechanically held lighting contactor is
designed to switch 20-ampere tungsten, ballast (fluorescent or
mercury arc), and 30-amp general use loads. The coil is only
energized for a short duration to allow the latch to hold the power
contacts closed thus preventing ac hum and insuring quiet
operation. Mechanically held operation allows the contactor to
remain "on" during power outage.
The CR360ML2 contactor may be controlled by a remote push
button, selector switch, or other pilot device. Optional solid-state
control modules are available to allow control of the lighting
contactor directly from energy management systems, microprocessors, timers, and similar control devices.
At AC
Service
Voltage
When Used with
Molded Case Circuit Breakers
Withstand
Current Rating
(Amps)
Maximum
Breaker Size
(Amps)
250V
22,000
30
480V
14,000
30
600V
10,000
30
Inrush Current/Minimum Control Line Fuse©
Amps
Inrush Current and Fuse Size
(Amps rms} at AC Control Voltage
120V
Description
The CR360ML2 mechanically held contactor is available in two,
three, four, six, eight, ten, or twelve normally open pole forms in a
compact, light-weight design. Coils are designed to be changed
to satisfy different standard control voltage requirements of 110120 Volts and 265-277 Volts. For high fault-current protection the
CR360ML2 has the highest available UL listed withstand current
ratings. Optional solid-state control modules are available fortwoor three-wire control and on-off control.
277V
Inrush
50
2.2
Fuse
2.0
1.0
© The minimum permissible control circuit fuse size is based on the
operating coil's momentary inrush current.
© Overcurrent protective device ratings for control circuits should be
selected in accordance with applicable electrical codes.
Note: Use of energy management systems, multiple control
stations, or signals require prime control logic or use of a 2-wire
control relay/module, to assure that on and off signals are never
applied simultaneously to a mechanically held contactor.
Features
• Light-weight, compact, easy to install
• Unique patented cam core operator mechanism
• High fault current protection:
Withstand current rating of 22,000 rms symmetrical
Amperes at 250 Volts and 10,000 rms symmetrical
Amperes at 600 Volts
• Visible indication of open or closed contacts
• Contact blocks can be added in the field
• Two auxiliary SPOT contacts available
• Field-installed modifications
References:
Instructions GEH-5445
Data subject to change without notice
1999 Issue
6-5
Download