GE Lighting Contactors CR360ML2 Mechanically Held Lighting Contactors 600 Volts Maximum 50/60 Hertz 20 Amperes Continuous GE Fastrac™ Program items are printed in red type. Ordering Directions Order by complete catalog number. Select number of poles and enclosure from Table O, select coil voltage from Table CD, for additionally modified forms, use Tables O, O, O, and 0. Minimum catalog number is 10 digits. _ Poles and Enclosure Aux. Contacts Ctl. Module and Volts Pilot Devices Control Power CR360ML2 O <D | O O O 0 Voltage Minimum complete catalog # 10 digits through enclosure. List Price, GO-10MB +o $ + <E> +0 $0.00 Example: 20-Amp mechanically held lighting contactor with 6 NO poles in a Type 1 enclosure with 120 V separate control 1 NO/1 NC auxiliary contact and red on pilot light. CR360ML2 List Price, GO-10MB 6NO Poles, Type 1 Enclosure + 120V Coil + 1 NO/1 NC Auxiliary No Control Module Red Indicating Light + No Fuses or CRT $ $ $ $ $ +© +o +0 Total O Select Pole Configuration and Enclosure Pole Configuration Open NC NO 0 0 0 0 0 0 0 2 3 2 3 4 6 8 10 12 2 3 4 6 4 6 List Price, GO-10MB Cat. No. Digits CR360ML2 List Price, GO-10MB o • . $287.00 305.00 318.00 492.00 548.00 609.00 701.00 340.00 514.00 570.00 723.00 02* G 03*G 04*G 06*G 08*G 10*G 12*G 22*G 33-G 44*G ,,., • i $305.00 323.00 336.00 552.00 608.00 669.00 761 .00 358.00 574.00 630.00 783.00 08"A 10*A 12*A 22*A 33*A 44*A 66*A 552.00 66.00 0.00 202.00 0.00 820.00 Type 12 Type 1 Cat. No Digits CR360ML2 03*A 04*A 06*A $ $ $ $ $ $ Cat. No. Digits CR360ML2 02*D 03* D 04*D 06*D 08*D 10*D 12*D 22*D 33*D 44*D 66* D Type 3R List Price, GO-10MB $395.00 413.00 426.00 642.00 698.00 759.00 851.00 448.00 664.00 720.00 873.00 Cat. No, Digits CR360ML2 List Price, GO-10MB $395.00 413.00 426.00 642.00 698.00 759.00 851.00 448.00 664.00 720.00 873.00 02* R 03*R 04* R 06* R 08* R 10*R 12*R 22* R 33* R 44*R 66* R * Insert voltage from Table (D; if no additional modifications, 10-digit catalog number is complete. <D Select Input Coil Voltage o Se|ect Without CPT Contactor Voltage With CPT Cat. No. Line VoltageControl Voltage Cat. No, Digit 220-240 V 60 Hz— 1 20 V 60 Hz B Digit 120V60HZ K 277V 60 Hz 440-480V60HZ — 120V60HZ c 208V60HZ— 120V60HZ D 2 7 7 V 6 0 H Z — 120V60HZ K Auxiliary Contacts Auxiliary Contacts Cat. No. List Price, GO-10MB Digit None A — 1 NO and 1 NC (SPOT) B $ 66.00 2 NO and 2 NC (DPDT) CD C 132.00 © Not available with pilot light option. O Select Control Module and Module Voltage 120 Volts Control Module Cat. No. Digits 24 Vac/dc 277 Volts List Price, GO-10MB Cat, No. Digits List Price, GO-10MB Cat. No. Digits List Price, GO-10MB None AA — AA — On/Off Control 11 $430.00 12 $430.00 13 $430.00 2-Wire Control® 21 382.00 22 382.00 23 382.00 3- Wire Control® 31 409.00 32 409.00 33 409.00 ® Not available with push button control. O Select Control Power Option ® Not available with selector switch. O Select Pilot Devices—Indicating Lights No Indicating Light Push Button or Selector Switch Cat. No. Digit List Price, GO-10MB None A — Cat. No. Red On Indicating Light Cat. No Green Off Indicating Light Red On/Green Off Indicating Light List Price, GO-10MB Cat. No. Digit List Price, GO-10MB Cat. No. Digit Digit List Price, GO-10MB H $202.00 S $202.00 M $404.00 HOA Selector Switch C 165.00 B 367.00 N 367.00 J 569.00 On/Off Selector Switch E 165.00 D 367.00 P 367.00 K 569.00 On/Off Push Button G 248.00 F 450.00 R 450.00 L 652.00 6-6 1999 Issue Digit List Price, GO-10MB Standard A — Fused Control Circuit D $165.00 1 50 VA CPT with 1 Secondary Fuse S 202.00 1 50 VA CPT with 2 Primary and 1 Secondary Fuse T 367.00 Prices ami data subject to change without notice Gf Lighting Contactors CH360ML2 Mechanically Held Lighting Contactors 600 Volts Maximum 50/60 Hertz 20 Amperes Maximum GE FASTRAC™ Program items are printed in red type. Maximum AC Voltage and Amp Ratings for Main Contacts (Open or Closed) Po es Load Type Amperes Continuous 1 for 1 Phase 2 for 1 Phase 3 for 3 Phase Tungsten 20 250 Vac 250 Vac Ballast 20 347 Vac 600 Vac General 30 347 Vac 600 Vac Maximum DC Voltage and Amp Ratings for Main Contacts (Open or Closed) Poles t o Load Load Type Amperes Continuous 2 in Series 3 in Series General 20 125Vdc 250 Vdc Withstand Current Ratings for Contactor Typical CR360ML2 Contactor Available Symmetrical Amperes rms Application The new CR360ML2 mechanically held lighting contactor is designed to switch 20-ampere tungsten, ballast (fluorescent or mercury arc), and 30-amp general use loads. The coil is only energized for a short duration to allow the latch to hold the power contacts closed thus preventing ac hum and insuring quiet operation. Mechanically held operation allows the contactor to remain "on" during power outage. The CR360ML2 contactor may be controlled by a remote push button, selector switch, or other pilot device. Optional solid-state control modules are available to allow control of the lighting contactor directly from energy management systems, microprocessors, timers, and similar control devices. At AC Service Voltage When Used with Molded Case Circuit Breakers Withstand Current Rating (Amps) Maximum Breaker Size (Amps) 250V 22,000 30 480V 14,000 30 600V 10,000 30 Inrush Current/Minimum Control Line Fuse© Amps Inrush Current and Fuse Size (Amps rms} at AC Control Voltage 120V Description The CR360ML2 mechanically held contactor is available in two, three, four, six, eight, ten, or twelve normally open pole forms in a compact, light-weight design. Coils are designed to be changed to satisfy different standard control voltage requirements of 110120 Volts and 265-277 Volts. For high fault-current protection the CR360ML2 has the highest available UL listed withstand current ratings. Optional solid-state control modules are available fortwoor three-wire control and on-off control. 277V Inrush 50 2.2 Fuse 2.0 1.0 © The minimum permissible control circuit fuse size is based on the operating coil's momentary inrush current. © Overcurrent protective device ratings for control circuits should be selected in accordance with applicable electrical codes. Note: Use of energy management systems, multiple control stations, or signals require prime control logic or use of a 2-wire control relay/module, to assure that on and off signals are never applied simultaneously to a mechanically held contactor. Features • Light-weight, compact, easy to install • Unique patented cam core operator mechanism • High fault current protection: Withstand current rating of 22,000 rms symmetrical Amperes at 250 Volts and 10,000 rms symmetrical Amperes at 600 Volts • Visible indication of open or closed contacts • Contact blocks can be added in the field • Two auxiliary SPOT contacts available • Field-installed modifications References: Instructions GEH-5445 Data subject to change without notice 1999 Issue 6-5