Fan Pack II A Choice of Styles for You to Choose: • 1,000 to 10,000 cfm collectors for particulate/gases/bioaerosols TRUST - we provide the best for you. Pa r t i a l L i s t i ng o f Appli c a t i ons : • Metalworking, machining & gr i n d i n g sm oke & dust • Welding & soldering fum es • Vinyl extrusion plastic iz ers • Rubber c uring & form ing sm oke • Vac uum pum p exhaust • Storage warehouse air c leanin g • Solvent c leaning & gluing fum e s • Offset print ing powders • Heat t reat ing sm oke • Diesel engine exhaust Flanders/Air Seal at work for you... Depend on Fan Pack II for the collection of particulate, gases and bioaerosols. Flanders/Air Seal Fan Pack II’s are fully self-contained, industrial grade air cleaning systems, designed for precise control of particulate, gas-phase and bioaerosol contaminants (or any combination) from process or ambient air. These units feature a broad range and combination of filtration components that allow for exact controls to be selected and packaged to meet individual applications. The available components include the finest in medium, high, and HEPA efficiency filters, UVC Systems and TechSorb chemical media. Fan Pack II’s feature integral fans sized to fit the specified demand and efficiently deliver the required air volume. The unitary designs include a 3” integral base, complete fan isolation and extruded aluminum filter tracks equipped with woven pile filter seals. All joints are coated with silicone compound and all access doors are equipped with neoprene gaskets and bolt down, knurl-knob latches to provide the finest seal against ambient air. Fan Pack II’s can be installed as ducted systems to control particulate, gas phase and/or bioaerosol contaminants at the source or without ductwork to remove fugitive airborne contaminants. Flanders/Air Seal will help you assess your air pollution requirements to select the right Fan Pack II configuration for your specific needs. Applications Fan Pack II’s are available in 14 single and multi-stage filtration component configurations to solve a wide variety of air pollution problems. They are used to remove nuisance or hazardous airborne contaminants from manufacturing processes, laboratory environments, isolation rooms, and a host of other areas. Design engineering that is flexible... Flanders offers an Engineering Department that can provide realtime solutions. Changes can be made at any point in the process. The changing world we like in demands that the manufacturing process be flexible at all times and be able to respond to the customers requests. Every job has its hidden information and newly discovered opportunities. Flanders has an Engineering Department that is responsive on many levels. The Engineers at the actual Assembly Shop are supported by a Corporate Engineering Department that can provide additional resourses when needed. All 3D Modeling is currently performed at the Corporate Engineering Department located in Washington, North Carolina. General Description The air cleaner is a unitary industrial type, furnished as a side access housing, containing stage(s) of particulate air filter, ultraviolet light system, and/ or gas-phase sorbent media, complete with integral blower and motor sized to deliver the air volume as specified. Construction Unit housing is constructed from 16 gauge galvanized steel (optional stainless steel, or aluminum), welded, with all interior and exterior metal-to-metal joints sealed with silicone compound, mounted on a painted, 3” base. Optional unit paint coatings are available to meet the end users needs. Access doors are fully gasketed on the inside with high memory neoprene gasketing. Interior of access doors and cabinet are supplied with gasketing to seal against the vertical edges of filters. Filter tracks are fully gasketed and provide positive seal against filter media to prevent air by-pass. Blower/Motor The blower/motor is mounted on a heavy duty, unitary frame and use rubber-in-shear vibration isolators and neoprene coated flexible fabric for blower/motor-to-cabinet connections. The blower is furnished with fixed sheave and the motor has an adjustable sheave and drive belt. The blower is either double width double inlet with forward curved wheel or backward inclined plenum fan. The motor is an open drip proof, 3 Phase/ 60 Hz/ 208-230-460VAC, rated for continuous duty. General Information BI/AF and Centrifugal Blowers Exterior Housing Completely Sealed All interior and exterior metal-to-metal connections are sealed with silicone compound for maximum sealing integrity All blowers are connected to the unit with neoprene coated flexible fabric and rubber-in-shear isolators. Heavy Duty Knurl Knob Latches Access doors are fitted with bolt-down knurl-knob latches that assure maximum sealing integrity. Fully Gasketed Access Doors High memory neoprene gasket for complete door closure and filter sealing. Extruded Aluminum Filter Tracking Extruded aluminum tracking, combined with reinforced woven nylon pile seal creates corrosion resistant filter seal. Rugged Construction All units are factory assembled in a “one piece” unit constructed of 14 or 16 ga. galvanized steel with 3” integral base. Unit shown - Model PBH-1 with 30% prefilter, 95% bag filter, 99.97% HEPA and backward inclined plenum blower/motor. * Industrial exhaust unit depicted above; clean air supply and similar applications should utilize Fan Pack III and Fan Pack IV. Notes 1. Fan Pack II’s are shipped with filters as specified per the purchase order. 2. Pleats, bags and collectors are shipped installed in the Fan Pack II housing. HEPA filters and carbon panels are shipped individually packaged. 3. Refer to applicable unit submittal drawing for complete actual dimensions 4. Special blower/motor combinations are available. Flanders/Air Seal offers multiple options to meet your projects requirements. These include but are not limited to: 1. Fans a. Plenum b. Centrifugal DWDI i. Backward inclined a. Steel ii. Airfoil 2. Low leak dampers and louvers b. Stainless steel 3. Casing material selection: a. Epoxy painted galvanized steel b. 304 or 316 stainless steel (standard) c. Aluminum 4. Insulation: a. Fiberglass 1” to 4” 3 lb. density i. Foil back ii. Mastic coated b. Armaflex 1” and 2” c. Foam board ½” to 4” 5. Specialized latches: a. Positive pressure trip-lock b. Cam lock latch latch a. 3” Hinge (standard) removed easily in tight locations a. Air dry epoxy in a variety of colors b. Air dry polyurethane in a variety of colors c. Heresite Coating 8. Pressure gages mounted flush, external, b. Uni-Hinge – allows door to be c. Piano hinges 7. Paint coatings c. Ventlok latch 6. Specialized stainless steel hinges: or swung open in normal locations or remote a. Magnehelic b. Photohelic c. Manometer d. Minihelic e. Capsuhelic 9. Weatherproofing Fan Pack II 3 Fan Pack II Selection Guide Model “P” / Single-Stage Model “PC” / 2-Stage 30% prefilter 30% prefilter - activated carbon Model CFM ISP Size Height Width Depth HP Model CFM ISP Size Height Width Depth P-1 1,000 1.0” 1x1 26.25” 24.00” 34.00” 1 PC-1 1,000 1.25” 1x1 26.25” 24.00” 68.00” 1 P-2 2,000 1.0” 1x1 26.25” 24.00” 34.00” 2 PC-2 2,000 1.25” 1x1 26.25” 24.00” 68.00” 1.5 P-3 3,000 1.0” 1x1-1/2 26.25” 36.00” 42.00” 3 PC-3 3,000 1.25” 1x1-1/2 26.25” 36.00” 73.00” 3 P-4 4,000 1.0” 1x2 26.25” 48.00” 40.00” 3 PC-4 4,000 1.25” 1x2 26.25” 48.00” 78.00” 3 P-6 6,000 1.0” 1-1/2x2 38.50” 48.00” 46.00” 5 PC-6 6,000 1.25” 1-1/2x2 38.50” 48.00” 82.00” 5 P-8 8,000 1.0” 2x2 50.50” 48.00” 54.00” 5 PC-8 8,000 1.25” 2x2 50.50” 48.00” 82.00” 7.5 P-10 10,000 1.0” 2x2-1/2 50.50” 59.00” 58.00” 5 PC-10 10,000 1.25” 2x2-1/2 50.50” 59.00” 85.00” 7.5 Model “PR” / 2-Stage HP Model “PRC” / 3-Stage 30% prefilter - 95% rigid filter 30% prefilter - 95% rigid filter- activated carbon Model CFM ISP Size Height Width Depth HP Model CFM ISP Size Height Width Depth HP PR-1 1,000 1.8” 1x1 26.25” 24.00” 50.00” 1 PRC-1 1,000 2.1” 1x1 26.25” 24.00” 80.00” 1 PR-2 2,000 1.8” 1x1 26.25” 24.00” 54.00” 3 PRC-2 2,000 2.1” 1x1 26.25” 24.00” 82.00” 3 3 PRC-3 3,000 2.1” 1x1-1/2 26.25” 36.00” 83.00” 5 PR-3 3,000 1.8” 1x1-1/2 26.25” 36.00” 56.00” PR-4 4,000 PR-6 6,000 1.8” 1x2 26.25” 48.00” 56.00” 5 PRC-4 4,000 2.1” 1x2 26.25” 48.00” 85.00” 5 1.8” 1-1/2x2 38.50” 48.00” 62.00” 7.5 PRC-6 6,000 2.1” 1-1/2x2 38.50” 48.00” 92.00” 10 PR-8 8,000 PR-10 10,000 1.8” 2x2 50.50” 48.00” 68.00” 7.5 PRC-8 8,000 2.1” 2x2 50.50” 48.00” 96.00” 10 1.8” 2x2-1/2 50.50” 59.00” 68.00” 7.5 PRC-10 10,000 2.1” 2x2-1/2 50.50” 59.00” 100.00” 10 Model “PBC” / 3-Stage Model “PB” / 2-Stage 30% prefilter - 95% bag filter - activated carbon 30% prefilter - 95% bag filter Model CFM ISP Size Height Width Depth HP Model CFM ISP Size Height Width Depth HP PB-1 1,000 1.8” 1x1 26.25” 24.00” 64.00” 1 PBC-1 1,000 2.1” 1x1 26.25” 24.00” 94.00” 1 PB-2 2,000 1.8” 1x1 26.25” 24.00” 68.00” 3 PBC-2 2,000 2.1” 1x1 26.25” 24.00” 98.00” 3 3 PBC-3 3,000 2.1” 1x1-1/2 26.25” 36.00” 98.00” 5 PB-3 3,000 1.8” 1x1-1/2 26.25” 36.00” 70.00” PB-4 4,000 PB-6 6,000 1.8” 1x2 26.25” 48.00” 70.00” 5 PBC-4 4,000 2.1” 1x2 26.25” 48.00” 98.00” 5 1.8” 1-1/2x2 38.50” 48.00” 76.00” 7.5 PBC-6 6,000 2.1” 1-1/2x2 38.50” 48.00” 107.00” 10 PB-8 8,000 PB-10 10,000 1.8” 2x2 50.50” 48.00” 82.00” 7.5 PBC-8 8,000 2.1” 2x2 50.50” 48.00” 112.00” 10 1.8” 2x2-1/2 50.50” 59.00” 88.00” 7.5 PBC-10 10,000 2.1” 2x2-1/2 50.50” 59.00” 116.00 10 4 Fan Pack II Note: Refer to a Flanders catalog to select your filters. Fan Pack II Selection Guide Model “PH” / 2-Stage Model “PHC” / 3-Stage 30% prefilter - 99.97 HEPA 30% prefilter - 99.97% HEPA - activated carbon Model CFM ISP Size Height Width Depth HP Model CFM ISP Size Height Width Depth HP PH-1 1,000 2.5” 1x1 26.50” 30.00” 70.00” 1 PHC-1 1,000 2.75” 1x1 26.50” 30.00” 102.00” 1 2,000 2.75” 1x1 26.50” 30.00” 102.00” 2 PH-2 2,000 2.5” 1x1 26.50” 30.00” 70.00” 1.5 PHC-2 PH-3 3,000 2.5” 1x1-1/2 26.50” 39.00” 64.00” 3 PHC-3 3,000 2.75” 1x1-1/2 26.50” 39.00” 107.00” 3 PH-4 4,000 2.5” 1x2 32.00” 51.00” 70.00” 3 PHC-4 4,000 2.75” 1x2 29.00” 51.00” 100.00” 5 PH-5 6,000 2.5” 1-1/2x2 39.00” 51.00” 75.00” 5 PHC-6 6,000 2.75” 1-1/2x2 39.00” 51.00” 123.00” 7.5 PH-8 8,000 2.5” 2x2 51.00” 51.00” 87.00” 7.5 PHC-8 8,000 2.75” 2x2 51.00” 51.00” 124.00” 7.5 7.5 PHC-10 10,000 2.75” 2x2-1/2 51.00” 64.00” 112.00” 10 PH-10 10,000 2.5” 2x2-1/2 51.00” 64.00” 82.00” Model “PRH” / 3-Stage Model “PBH” / 3-Stage 30% prefilter - 95% rigid filter - 99.97% HEPA 30% prefilter - 95% bag filter - 99.97% HEPA Model CFM ISP Size Height Width Depth HP Model CFM ISP Size Height Width Depth HP PRH-1 1,000 3.1” 1x1 26.50” 30.00” 93.00” 1 PBH-1 1,000 3.1” 1x1 26.50” 30.00” 101.00” 1 PRH-2 2,000 3.1” 1x1 26.50” 30.00” 93.00” 2 PBH-2 2,000 3.1” 1x1 26.50” 30.00” 101.00” 2 PRH-3 3,000 3.1” 1x1-1/2 26.50” 39.00” 98.00” 3 PBH-3 3,000 3.1” 1x1-1/2 26.50” 39.00” 106.00” 3 PRH-4 4,000 3.1” 1x2 29.00” 51.00” 92.00” 5 PBH-4 4,000 3.1” 1x2 29.00” 51.00” 100.00” 5 PRH-5 6,000 3.1” 1-1/2x2 39.00” 51.00” 105.00” 7.5 PBH-6 6,000 3.1” 1-1/2x2 39.00” 51.00” 113.00” 7.5 PRH-8 8,000 3.1” 2x2 51.00” 51.00” 113.00” 7.5 PBH-8 8,000 3.1” 2x2 51.00” 51.00” 121.00” 7.5 PRH-10 10,000 3.1” 2x2-1/2 51.00” 64.00” 118.00” 10 PBH-10 10,000 3.1” 2x2-1/2 51.00” 64.00” 126.00” 10 Model “PRR” / 3-Stage Model “V” / 2-Stage 30% prefilter - 65% rigid filter - 95% rigid filter 30% Vee bank filter Model CFM ISP Size Height Width Depth HP Model CFM ISP Size Height Width Depth HP PC-1 1,000 1.25” 1x1 26.25” 30.00” 84.00” 1 V-1 1,000 1.0” 1x1 26.25” 24.00” 58.00” 1 PC-2 2,000 1.25” 1x1 26.25” 30.00” 84.00” 2 V-2 2,000 1.0” 1x1 26.25” 24.00” 60.00” 2 PC-3 3,000 1.25” 1x1-1/2 28.00” 36.00” 87.00” 3 V-3 3,000 1.0” 1x1-1/2 26.25” 36.00” 64.00” 3 PC-4 4,000 1.25” 1x2 32.00” 48.00” 89.00” 5 V-4 4,000 1.0” 1x2 26.25” 48.00” 64.00” 3 PC-5 6,000 1.25” 1-1/2x2 38.50” 48.00” 102.00” 5 V-6 6,000 1.0” 1-1/2x2 38.50” 48.00” 74.00” 5 PC-8 8,000 1.25” 2x2 50.50” 48.00” 204.00” 7.5 V-8 8,000 1.0” 2x2 50.50” 48.00” 76.00” 5 PC-10 10,000 1.25” 2x2-1/2 50.50” 59.00” 108.00” 7.5 V-10 10,000 1.0” 2x2-1/2 50.50” 59.00” 80.00” 5 Note: Refer to a Flanders catalog to select your filters. Fan Pack II 5 Fan Pack II Suggested Specification General: Factory fabricated blow-through and draw-through packaged filtration units. Unit casing Exterior casing shall be constructed of minimum 16gauge galvanized steel. Exterior panels shall be turned inward to provide a clean flush exterior finish. The unit shall be caulked with silicon sealant to produce an air tight seal. Insulation (optional) Interior insulation shall be a minimum of 1” thick 1-1/2 pound per cubic foot density fiberglass duct board with foil backing. All edges shall be taped to insure no insulation is in the air stream with 3” foil tape. Insulation shall comply with NFPA 90a. The fiberglass shall be glued and fastened to the cabinet wall with stick clips. Other options available upon request. Unit base Continuously seam welded structural steel channel reinforced to support all internal components on a common channel frame. Units less than or equal to 12’ long, the base shall be constructed of 3” coated channel iron. Units less than 20’ but greater than 12’ long, the base shall be constructed of 4” coated channel iron. All units over 20’, the base shall be constructed of 6” coated channel iron. Provide lifting lugs approximately every 12’, minimum (4) per unit. Access doors Access doors shall provide service to all internal components. Access doors for insulated units to be double wall insulated with 1” thick 1-1/2 pound per cubic foot density fiberglass complying with NFPA 90a. Outer wall to be 16gauge galvanized steel. Inner wall to be minimum 20-gauge galvanized steel. Doors shall swing freely on stainless steel hinges. Door latches shall be positive pressure snap action bassick latches on all units with total static pressure of 2-1/2” w.c. Door perimeter gasket shall be continuous neoprene gasket. Note: all units greater than two filters wide shall have doors on both sides of unit. after machining. Units larger than 1,000 cfm. Blower shall be complete with pillow block bearings, angle iron frame around perimeter of blower housing, and shall be equipped with zerk fittings for future lubrication. Lubrication lines shall be extended to exterior of unit to permit lubrication for both bearings from access door side of unit. All blowers shall be flex connected to housing by means of flexible fabric. Motor assembly shall be mounted on an integral all welded epoxy coated fanmotor base constructed of no less than 1 ½” angle iron. Fan base to be isolated to housing be means of rubber-inshear isolators when size permits, 1” deflection seismic spring isolators when size dictates. Backward inclined double width, double inlet blower shall be sized for 130% of initial static pressure plus external static duct loss. All fans shall be tested in accordance with AMCA 210-70 test code for air moving devices. Fan shaft shall be solid (hollow shafts are not acceptable) shaft shall be ground and polished carbon steel SAE 1045 material or equal. Machined to close tolerances, keyed to fan wheel. Fan shall be coated with a rust inhibitor after machining. Blower shall be complete with pillow block bearings, angle iron frame around perimeter of blower housing, and shall be equipped with zerk fittings for future lubrication. Lubrication lines shall be extended to exterior of unit to permit lubrication for both bearings from access door side of unit. All blowers shall be flex connected to housing by means of flexible fabric. Motor assembly shall be mounted on an integral all welded epoxy coated fan-motor base constructed of no less than 1 ½” angle iron. Fan base to be isolated from housing by means of rubber-in-shear isolators when size permits, or 1” / 2” deflection seismic spring isolators. Vibration isolators Fan and motor shall be mounted on all welded, structural steel, unitary, epoxy coated, integral fan/motor base with isolators selected to provide 96% isolation efficiency from the unit structure. Rubber-in-shear elastomeric mounting having a steel base plate with mounting holes and a threaded insert at top of the mounting for attaching fan base. All metal parts shall be completely embedded in the elastomeric material. Mountings shall be designed for approximately ½” deflection. Spring Fans Forward curved double width, double inlet blower shall isolators shall be designed to resist seismic forces in all be sized for 130% of initial static pressure plus external directions and shall be constructed of welded steel with static duct loss. All fans shall be tested in accordance neoprene cushioned contact surfaces. These restraints with AMCA 210-85 test code for air moving devices. Fan will reduce shock during an earthquake and not engage shaft shall be solid (hollow shafts are not acceptable) during normal operation. Springs shall be adjustable for shaft shall be ground and polished carbon steel SAE 1045 leveling and shall be furnished with a neoprene sound material or equal, machined to close tolerances, keyed absorbing pad for high frequency isolation. Springs to fan wheel. Fan shall be coated with a rust inhibitor shall be approved for zone 4 applications. Compressed 6 Fan Pack II Fan Pack II Suggested Specification operating height to spring diameter ratio is 1 to 1. Spring deflection shall be 1-1/2” minimum. Note: all units less than or equal to 8000 cfm shall have rubber-in-shear isolators. Note: all units greater than 8000 cfm shall have spring isolators. dampers shall be of the same high quality. All dampers shall rotate in nylon rustproof type bushings and have a linear type operation. All dampers are factory installed opposed blade. Minimum outside air damper: The integral air monitor/damper shall have measuring ports built into the damper blades and shall control the minimum amount of outside air as recommended by Motors ASHRAE standard 62. The air /monitor damper shall Motor shall be minimum size indicated in the project have an Aluminum frame. The frame shall be designed drawing schedule or large enough so that the motor will for 4 bolt and/or flange cleat installation and shall not be required to operate in the service factor. Several provide maximum free area for lowest pressure drop enclosures are available: (ODP) open drip proof - where performance. Damper blades shall be heavy gauge motors are located inside of housing or in a safe area. aluminum airfoil type. Damper linkage shall be out of (TEFC) totally enclosed fan cooled - where motors are the air stream and located within the damper frame to located outside of unit not in safe area (TEFC-HI-EFF) reduce pressure drop and noise. Jamb seals shall be totally enclosed fan cooled - high efficiency where flexible metal compression type. The assembly on the motors are to be used in conjunction with variable damper/monitor shall incorporate an air straightener frequency drives (subject to VFD manufacturer vane to ensure proper airflow readings. approval). (X-proof) explosion proof where motors are to be located in a hazardous areas (motor to be able Each air monitor /damper shall include 24VAC electric to withstand an explosion from with-in, and prevent modulating motor and an application specific controller ignition in the surrounding environment.). Motors designed for this for this application furnished by the shall operate at 60hz. And have a service factor of 1.15 damper manufacture. Each integral air monitor/damper For single and three phase motors. Motors shall be shall be calibrated in an AMCA registered laboratory and constructed to NEMA standard MG 1, general purpose, a certification chart shall accompany it. continuous duty, design B. Motor bearings shall be either roller or ball bearings with inner and outer shaft seals. Finish (optional) Motors shall be resistant to thrust loading where belt Unit shall be undercoated inside and out prior to drives or other drives produce axial or lateral thrust in insulating with a minimum of 2 mls. Thick of uni-primer. motor. Fan/motor combination shall come up to speed Final coat shall be a minimum of 2 mls. Thick of two part in 10 seconds or less. air dried epoxy. Drives Weatherproofing (optional) Filte tracking Electrical (optional) Fan / blower drive shall be v-belt fixed hitch. Motor Suitable for outdoor installation, weatherproof design. sheaves shall be variable pitch up to and equal to 5 hp. All outdoor units shall have a sloped (pitched) roof rain Motors 7.5 hp and larger shall have fixed hitch sheaves. guards over each door. The Fan Pack II unit accommodates a variety of filters. Filter tracking depends on the filter selection. Pre filter shall be a minimum of 2” thick. Filter installation is side access slide in. On all units requiring a vee bank arrangement in the pre filter section, a formed 20 ga. galvanized track is used. Extruded aluminum track shall be used on all other filter combinations. Extruded aluminum track shall have a woven pile seal mechanically fastened to the downstream side of each track. Dampers (optional) Mixing damper section: the outside air dampers shall be the high efficiency, low leak, high quality type with neoprene blade seals and edge seals. The return air Variable frequency drive wired to motor with flexible conduit. Gages (optional) Photohelic –mounted, not wired Magnehelic -mounted Other gages are available upon request Options Customer specified options and deviations from this standard specification are part of the design and submittal process. The customer’s requirements and needs can be incorporated into this specification to make the units conform to the specific application. Fan Pack II 7 PB4002-0110 Representatives of Flanders Corporation are located throughout the world. Your closest representative’s office may be found by contacting our manufacturing and sales department. Distributed By: Company Headquarters: 531 Flanders Filters Road Washington, NC 27889 United States +1.800.637.2803 flanderscorp.com