Emergency lighting units PC COMBO PC CFL COMBO, 220 – 240 V 50/60 Hz Compact fluorescent lamps Product description _ Combination of electronic ballast and emergency lighting unit _ For compact fluorescent lamps _ For manual testing of the emergency lighting function _ 5-year guarantee Properties _ Lightweight one-part emergency lighting unit _ Simple wiring _ No compatibility problems _ 3 h rated duration for TC-DD lamp variants _ 1 and 3 h rated duration for TC-D/T lamp variants _ Selectable operating time (jumper) _ Lamp warm start in normal operation _ Filament heating in emergency operation for TC-D/T lamps _ AC operation of all lamps _ Automatic restart after relamping in normal operation _ Green charge status display LED _ Intelligent Voltage Guard (overvoltage indication and undervoltage shutdown) _ Optional test switch _ Checking the emergency lighting function by interrupting the unswitched phase _ Small dimensions _ IDC (insulation displacement connection) _ Electronically controlled battery charging _ Deep discharge protection _ Short-circuit-proof battery connection _ Polarity reversal protection for battery Batteries _ Separate battery pack _ High-temperature cells _ NiCd or NiMH batteries _ D, Cs or LA cells _ 4-year design life _ 1-year guarantee Website http://www.tridonic.com/89899983 Article information 07/16 Subject to change without notice. www.tridonic.com 1 3 Emergency lighting units PC COMBO PC CFL COMBO, 220 – 240 V 50/60 Hz Compact fluorescent lamps 3 31 The complete data sheet for this product is available in the Downloads section. 6 6 4,3 D B 6,5 4,3 6,5 110,5 123 Ordering data Type Article number Number of cells Packaging, carton Packaging, pallet Weight per pc. 89899983 3 25 pc(s). 700 pc(s). 0.220 kg Rated operating time 3 / 1 h PC 1x26-3 TC COMBO Technical data Rated supply voltage Mains frequency Mains voltage changeover threshold Lamp starting time (normal operation) tc point max. Ambient temperature ta Operating frequency (normal operation) Operating frequency (emergency mode) Overvoltage protection Battery charging time Battery charging current 4 Ah / 4 Ah NiMH (3 h application) Battery charging current 1.6 Ah / 2 Ah NiMH (1 h application) Leakage current (PE) Min. lamp starting temperature (normal operation) Min. lamp starting temperature (emergency mode) Type of protection 220 – 240 V 50 / 60 Hz According to EN 60598-2-22 1.6 s 75 °C 0 ... +55 °C > 42 kHz typ. 17 kHz 320 V (for 1 h) 24 h 200 mA 100 mA < 0.5 mA -15 °C 0 °C IP20 Approval marks Standards Acc. to EN 50172, Acc. to EN 60598-2-22, EN 61347-2-3, EN 61347-2-7, EN 60929, EN 55015, EN 61000-3-2, EN 61000-3-3, EN 61547, EN 60068-2-29, EN 600682-30, EN 60068-2-64 Lamp power Circuit power Mains current2 24.0 W 24.0 W 28 W 28 W 0.130 A 0.130 A Rated duration Hole spacing D 66.5 mm 66.5 mm Emergency operation EBLF3 Dimensio ns L x W x H 123 x 79 x 31 mm 123 x 79 x 31 mm Emergency operation BLF Article number 89899983 89899983 Normal operation BLF Type PC 1x26-3 TC COMBO PC 1x26-3 TC COMBO Lamp wattage Lamp type 1 Specific technical data 1.00 1.00 0.095 0.065 0.080 0.055 3/1 h 3/1 h Rated operating time 3 / 1 h TC-DEL TC-TEL 1 x 26 W 1 x 26 W 0.95 0.95 1 PC 1x28-33 HO DD COMBO, PC 1x38-34 HO DD COMBO, PC 1x28-33 LO DD COMBO and PC 1x38-34 LO DD COMBO only for Biax non-amalgam lamps. 2 For 230 V, 50 Hz. Article information 07/16 Subject to change without notice. www.tridonic.com 2 3 Emergency lighting units PC COMBO 3 According to EN 61347-2-7 Article information 07/16 Subject to change without notice. www.tridonic.com 3 3