Optical slot sensors SL10 and SL(O)30 series optical slot sensors Wave length Red IR (infrared) Adjustment Supply Supply voltage Ripple Vpp No load current Dimensions [mm] Protection ● Cable 18,8 18,8 52 10 10 45 52 30,2 10 45 72 72 green LED yellow LED Potentiometer green LED yellow LED ø5,6 Potentiometer 2x (except 6 SLO30... models) 40 SL10... Output Continuous load current Switching frequency 40 ø5,6 2x 6 SL(O)30... ● Connector Material Housing Lens Protection class (IEC 60529/EN 60529) Temperature range Cable Connector Indicator LED’s Green Yellow Yellow flashing M 12 x 1 20,2 SL10... M 12 x 1 680 nm (SL10 and SL30) 890 nm (SLO30) sensitivity (SL10 and SL30) light/dark operate1) 10…30 V dc ≤ 10 % ≤ 30 mA reverse polarity transient voltages short-circuit ≤ 150 mA ≤ 500 Hz ≤ 1,6 kHz (...Y) glass-fibre reinforced polyester acrylic IP67 -40…+70 °C 2 m, PVC, 5 x 0,5 mm2 eurocon (M12 x 1) power-on output energised low gain 20,2 SL(O)30... Wiring BN (1) + WH (2) Accessories BK (4) BU (3) GY (5) 1) 1) - light operate: grey connected to “-” or open dark operate: grey connected to “+” Connector WAK4.5-2/P00 80 085 76 WWAK4.5-2/P00 80 085 83 straight type right-angled type 350 350 150 150 150 150 80 80 150 150 80 80 10 mm 10 mm 10 mm 10 mm 30 mm 30 mm 30 mm 30 mm 30 mm 30 mm 30 mm 30 mm red red red red red red red red IR IR IR IR pnp, npn pnp, npn pnp, npn pnp, npn pnp, npn pnp, npn pnp, npn pnp, npn pnp, npn pnp, npn pnp, npn pnp, npn cable connector cable connector cable connector cable connector cable connector cable connector Iden t nu mbe r Type Con nec tion Out put func tion Optical slot sensors Ligh t so urce optical slot sensors Max . exc ess gain * Slot widt h SL10 and SL(O)30 SL10VB6V SL10VB6VQ SL10VB6VY SL10VB6VYQ SL30VB6V SL30VB6VQ SL30VB6VY SL30VB6VYQ SLO30VB6 SLO30VB6Q SLO30VB6Y SLO30VB6YQ 30 583 23 30 583 24 30 603 67 30 603 68 30 565 65 30 565 67 30 565 66 30 565 68 30 597 68 30 597 69 30 597 71 30 597 72 * Excess gain: the amount of light on the receiver over and above the minimum amount of light required to operate the sensor. Subject to changes without notice • Edition 02.02 • P/N ED053 – excerpt from EC001/0102 ! These sensors do not include the self-checking redundant circuitry necessary to allow their use in personnel safety applications. A sensor failure or malfunction can result in either an energised or de-energised output condition. These products should not be used as sensing devices for personnel safety.