WHEREAS the City desires to participate in the State Cooperative

advertisement
RESOLUTION NO 2011 87
INTRODUCED BY COUNCILPERSONS WISNIESKI NARDUZZI PITEO
A RESOLUTION
AUTHORIZING THE PURCHASE OF A
2010 FORD E 450 DIESEL AMBULANCE
FOR THE FIRE DEPARTMENT
THROUGH THE STATE COOPERATIVE PURCHASING PROGRAM
AND DECLARING AN EMERGENCY
WHEREAS the Interim Fire Chief has requested to purchase
Diesel ambulance for the Fire
a
2010 Ford E 450
Department and
WHEREAS the City desires to participate in the State Cooperative Purchasing
Program ID Number 8318 and
WHEREAS the City has received a proposal from Burgess Ambulance Sales
Inc 527 Wooster Road Loudonville Ohio 44842 for the purchase and delivery of a
2010
Ford
E 450
ambulance for the Fire Department through the State
Cooperative Purchasing Program ID Number 8318 in an amount not to exceed One
Hundred Forty Seven Thousand Nine Hundred Ten Dollars 147
00 and
910
WHEREAS
Diesel
the
Interim
Fire
Chief
has
reviewed
the
specifications
and
recommends that Council authorize the
purchase and delivery of a 2010 Ford E 450
Department from Burgess Ambulance Sales Inc 527
Wooster Road Loudonville Ohio 44842 through the State Cooperative Purchasing
Program ID Number 8318 in an amount not to exceed One Hundred Forty Seven
Diesel ambulance for the Fire
Thousand Nine Hundred Ten Dollars
00
910
147
as
set forth in Exhibit A attached
hereto and
WHEREAS pursuant to Ohio Revised Code Section 125
B the City is not
04
bid
this
to
because
the
wishes
to participate in the
required
competitively
purchase
City
State Cooperative Purchasing Program
THEREFORE BE IT
Independence State of Ohio that
NOW
1
71770707
RESOLVED
by
the
Council
of
the
City
of
Section 1
The Council
hereby
authorizes the
purchase and delivery of a 2010
Department
Burgess Ambulance Sales
Inc 527 Wooster Road Loudonville Ohio 44842 through the State Cooperative
Purchasing Program ID Number 8318 in an amount not to exceed One Hundred Forty
Ford E 450 Diesel ambulance for the Fire
from
Seven Thousand Nine Hundred Ten Dollars
00
910
147
as
set forth in Exhibit A
attached hereto
Section 2
The
is
hereby authorized to execute such documents as are
s approval as to form to purchase the 2010 Ford
needed subject to the Law Director
E 450 Diesel ambulance for the Fire Department through the State Cooperative
Purchasing Program ID Number 8318
Mayor
Section 3
This Resolution is hereby declared to be an emergency measure
for
the
immediate
necessary
preservation of the public health safety and welfare of the
inhabitants of the City of Independence by reason of the immediate necessity of
providing equipment to
effect immediately upon
the Fire
its
Department Wherefore this
passage and approval by the Mayor
Introduced
September 13 2011
First
September 13
Reading
Passed
T
Resolution shall take
2011
6
trait
Gregory
K
Illb
ay
r
Attest
Susan E Kurshuk Clerk of Council
CERTIFICATE OF POSTING
N tike tntd
rsIgned Clerk
Cld hereby certify
vies
posted
on
of the
OW
O
Indspsn
Ms
0I
the foregoing 1
day of
the
Q1
l
0
e
end for the period of fifteen days thereafter by duty
posting true copies thereof in three of the most public
ol
Cout
rltrtAOd
1
71770707
the
t
b
d
sent p
fined
CUM
it
c
O
of Independence
Pillf
THE HEART OF CUYAHOGA COUNTY
6800 BRECKSVILLE ROAD
P
1
INDEPENDENCE
OHIO 44131
C
end
216
1 g 14
August 25
Ohio
524 4131
2011
Taft Stettinius and Hollister
3500 BP Tower
200 Public
Square
Cleveland Ohio 44114 2302
Attn Mr Greg O
Brien
Dear Mr O
Brien
Please prepare legislation to authorize the purchase of a new 2010 Ford E 450 diesel
ambulance from Burgess Ambulance Sales Inc 527 Wooster Road Loudonville Ohio
44842 for the Fire
Department This purchase would be made through the Ohio Department
Cooperative Purchasing Program and would be for a total not to
00 including delivery
910
147
of Administrative Services
exceed
A copy of the
is the
corresponding State bid contract schedule number 7723300708 is attached
proposal from Burgess The balance of the purchase information is as follows
Index Number
STS233
OAKS
25101700
Category
Federal ID Number
34 6001474
Contract ID
7723300708 1
State
Coop
ID Number
Vendor ID
8318
58468
Purchase order 2010 02074 for
budget
90 has been encumbered for this ambulance
000
000 to come out of line item
acquisition is 85
50000 Public Safety Equipment Fund
The 2011
for the balance of this
440 9500
Please note that
a
trade in value of 00
500 has been offered for the old ambulance
5
Ford also offers
a
700
4
00
Thank you for your
rebate for this
purchase payable
City
delivery
of vehicle
APPROVED
NOT Ap
of
after
help
Sincerely
Steven
as
Rega Interim Fire
Independence
Web Site
f
Chief
org
independenceohio
www
E mail webmail
PRINTED ON RECYCLED PAPER
org
@independenceohio
yr
Ambulance Sale
Hearse
a
20ll
July 2Q
City of I
demce
ATTN Mike Sklodowski
6800 Brecksville Road
Independence
Dear Mr
if you
3l
OB44
Sklodowski
purchase
the
foliowing
vehicle
through
the State Term Schedule the
20lO
price for l
all
includes
price
45A diesel will see
he page 30 This
Road Rescue l68 Ford E
standard features and the options listed below
Price
2008
1
00
570
115
ZU10 Ford E45O1G8 Road Rescue 4x2
SUSPENSION
92
7
1
RoadMaster
IPD
E350
O0
410
Bar ILOS
sway bar will
anti
RoadMaster
IPD
E450
Sway
Only
NOTE This
93
7
1
Rear
Rear
Sway
NOT work in
conjunction with On
Spot Chains
00
380
Bar ILOS
Only
OUTSIDE REAR VIEW MIRRORS
28
1
49
Velvac 2020 Deluxe White Mirrors Heated Remote
Mirror Assemblies
Supplied
Lights
Replace
Lighted
Turn
590D0
Signals
OEM Outside Mirrors in Forward Window Section Velvac
Control Panel Mounts to Interior Black Forward Section of Driver Side Window
to flash with OEM turn
signals
Ford E350 E450
CAB INTERIOR OPTIONS
I1
1
35
Thinsuate in Cab
Install
a
O
Ceiling
Iayer of Thinsulate acoustic insuiation
in the GEM cab
ceiting
STANDARD
21
1
41
Carpet Fioor
independence
Fire
Mats with Road Rescue
00
100
Logo
buent
Dcpa
PHONE 1419 994
5584
Page
P 0
BOX 180
LLs
Louoowv
OHIO 44842
1
Price
Ford E Series
WHEEL COVERS
24
1
20
Stainless steel wheel inserts and
lug
covers
0
with valve extension kit
STANDARD
MODULE TYPE
905
1
2
Increase the
1
rear
length of the Ultramedic module 6
axle Overall
body length
The increase will be added aft of the
00
800
to be 174
UNDERCOATING
2
3
The entire underbody
of exhaust
system
excluding
shall be
0
drive shaft wheels fuel tank and 12 inches either side
sprayed
with
undercoating for
rust
prevention corrosion
protection and added sound deadening
STANDARD
EXTERIOR MODULE CONSTRUCTION
14
3
The perimeter frame of the roof to consist of
securely
fastened and welded to the wall and
extrusion to be
a
3 inch
high
x
0
11
2 inch radius extrusion
ceiling structural framing The roof
fully enclosed and include vertical
center
supports
STANDARD ON ALL MODULES
15
3
Extreme 3M
Acrylic Bonding Tape
Exterior wall
extreme
panels
0
CV62F
and roof sheet to be bonded to the tube structure with 3M
bonding tape
STANDARD
16
3
0
Sub floor Gusset Supports
Fabricated gusset supports to be added for extreme structural integrity Gussets to be
welded into place where the subfloor structure meets the vertical wall tube structure
STANDARD
Independence
Fire
Department
Page
2
Price
17
3
Weld
The
Seams
Body
smooth to
0
above the side and
seams
provide
a
rear
entry doors will be welded full length and ground
seamless appearance
STANDARD
18
3
Plates and structural tubes
are
added
across rear
header and side walls to reduce
long
0
term stress in these areas
STANDARD
19
3
Single
Sheet Module Roof Sheet
The module roof to be
a
0
single sheet of aluminum and will have full perimeter weld
the roof radius extrusion to provide
permanent weather
a
proof
to
seal and to enhance the
structural design of the modular structure
STANDARD
20
3
Drop Curbside Forward Body Skirt Add Double Step ahead of the Curbside Wheelwell
Drop curbside forward body skirt
a
total of 5 Inches and Incorporate
the Side Entry Step well Increase the depth of stepwell inboard
as
far
00
450
a
Double Step in
as
sub structure
permits
Side surfaces to be Diamond Plate Step surface to be
a
combination of NFPA Diamond
Plate and removable 9 Grip Strut insert
The second step to be fabricated of NFPA Diamond Plate and installed
surface is
making
midway
two
equal
NOTE The skirt
between the
stepwell
so
that the step
floor surface and the module floor surface
steps into the vehicle
drop
on
the Type I
only will be
an
additional 1 1
2 inches
Ultramedic Promedic only
MODULE ENTRANCE DOORS
7
6
3
Rear Door Restraints
Polished Cast Aluminum Pin and Slot
Bolted to Both Door and Rear Module Wall with
Screws Washer and Nylon Locknut
135
on
4
1
x
Style
Hold
0
Open
20 Stainless Steel Machine
the Interior Door open position is
a
minimum of
degrees
STANDARD
Independence
Fire
Department
Page 3
Price
8
6
3
Curbside Door Restraint
Attached by 1
4
x
Heavy Duty gas spring hold
20 SS Machine Screws with
0
opens
4
1
x
20 Nut Inserts into Corner
Gusset in Door
Side entrance door to open to 90 degrees
STANDARD
10
6
3
Entry Door Paddle Handles
TriMark Two Point Cast
Housing Locking and Non Locking with floating
Each Door Skin
w
w
cam
Polished Chrome Handle
Mounted in CNC Cut
0
and
Opening
in
OEM Clamp Assembly
STANDARD
11
6
3
0
Module Entry Door Locks
All doors shall
incorporate double cut
non
directional tumbler assemblies that
are
keyed alike
STANDARD
12
6
3
Module Entrance Doors Fitted
w
TriMark High Strength Treated Steel Rotary Latches
4
Rotary latches mounted with 1
x
20 SS
tapered machine
screws
0
for flush fit
STANDARD
13
6
3
Nader Pins
TriMark
High Strength
Installed through jamb extrusion
Zinc Plated Steel Nader Pin
w
Compression Washer
0
into blind fastener
STANDARD
14
6
3
Entry
Door Interior Paddle Handles
Locking and
w
non
locking Mounted in CNC
OEM clamp assembly
0
TriMark 4 point cast Polished chrome finish
cut
opening in each entry
door
access
panel
Mounted to Interior Access Panel
STANDARD
17
6
3
0
Lubricate all Door Hardware
All paddle handles latches rods and springs shall be lubricated
prior
to
delivery
STANDARD
Independence
Fire
Department
Page
4
Price
22
6
3
Jamb Mounted
Magnetic Proximity Switch Door
0
Flush mounted and wired to activate the corresponding Load Scene and Interior
Dome
lights
STANDARD
40
6
3
Hidden
Hinge Entrance Door Seal
on
Door
0
Module entrance door jambs to be designed into the wall panels The entry doors to
be double box pan formed
with
configuration
Expand Polystyrene foam planking
insulation between the outer skin and inside pan There will be
interior door
to the door
panel for servicing the
that the
so
upper
latching system
is
a access
plate
rotary latch Weather stripping
protected from the elements
on
the
to be secured
The door
hinge
to be hidden behind the exterior door skin
The interior finish of the entry doors shall have primary module color paint
applied
STANDARD
41
6
3
0
Stainless Steel Kick Panels
Install Stainless Steel kick panels
on
the lower portion of the standard interior module
entrance doors
NOTE Do not
provide
access
plates in the Stainless Steel overlay for door hardware
access
STANDARD
42
6
3
Coil Cords for Electrical Circuits
Circuits
being
on
Entry
0
Doors
routed to the entrance doors to utilize coil cord cables
STANDARD
43
6
3
0
Entrance Door Diamond Grade Reflective Tape
3 Wide Red White Diamond Grade reflective stripe
on
the interior of side and
rear
module entrance doors Stripes shall be located just above bottom edge of the doors
and shall span the width of the interior door
60 sq in of total reflective
panels
Each stripe shall have
a
minimum
area
STANDARD
Independence
Fire
Department
Page 5
Price
SIDE DOOR STEP
5
8
3
0
Step Well Light
Wheien Mini LED
Whelen OS Mini LED
automatically light
Tight
45
degree installed
in the curbside
when the side entrance door is
stepwell
to
opened
STANDARD
BUMPER AND REAR STEP CONSTRUCTION
12
3
15
0
isolation Material Between Bumper Frame and Aluminum Components
All steel
rear
bumper
frames will include isolation material between the steel frame
and any aluminum components Frame shall have
rubberized coating
Scorpion TM polyurethane
applied
STANDARD
12
3
21
9 Recessing flip up
rear
bumper
00
130
in lieu of standard Includes reinforced bottom
INSULATION
13
3
10
0
Thinsulate Insulation Installed Over
Wall
areas
planking
that
are
too
Irregular Areas
irregular for polystyrene foam planking insulation
or
where
will interfere with wall outlets and wire chases to be insulated with 3M brand
acoustical Thinsulate insulation In addition install
over
interior walls of the exterior
compartment and wheeiwells
STANDARD
13
3
23
Thinsulate Acoustical Wall Insulation Package
Add
layer
of Thinsulate material
00
350
over
standard wall insulation to improve sound deadening Thinsulate layer shall be installed
over
wall tubes in
a
continuous sheet
Includes
changing wall panels
to 125
aluminum
COMBINATION RUB RAIL AND FENDER RING
15
3
61
00
100
Extruded Aluminum Crash Rail ILOS
install anodized aluminum lower
Independence
Fire
Department
body
crash rail ILOS
Page
6
Price
15
3
75
Polished Aluminum Fender Rings Offset
Mounted with
and
450
E350
long leg forward
00
120
drop skirt curbside of module only ILOS rubber
on
450
F350
SPLASH GUARDS AND RUNNING BOARDS
16
3
15
NFPA Diamond Plate
Running Boards
0
125 NFPA compliant Diamond Plate Running Boards with
integral Splash Guard
bolted to the chassis Mounting bolts and body penetrations to be coated with ECK
corrosion inhibitive material
E Series F Series CG Series and CK Series
STANDARD
16
3
18
Heavy Duty Rubber Mud Flaps w
Heavy Duty Rubber Mud
with 1
4
x
Flaps
20 Stainless Steel
RR
0
Logo
to be bolted to the wheel liner behind the rear duals
bolts washer and nylon Iocknut for
ease
of maintenance
and repair
STANDARD
CAB TO MODULE ACCESS
19
3
20
The cab to module walk
hinged door
in the open
Overall door
height to
through
or
to include
closed
a
clear fixed window and
position with the
accommodate
actuator latch
a
self
being
0
latching
on
the cab side
fluid dam
a
STANDARD
19
3
21
0
Cab to Module Fluid Dam
A formed fluid
to
dam 4 tall
prevent fluids from
to be installed below the cab to module walk
through door
contaminating the cab The floor and fluid dam to be
fully sealed
STANDARD
LICENSE PLATE HOLDER
20
3
5
0
Cast Aluminum License Plate Holder
Installed in the
rear
curbside module
panel Includes 2 Whelen
body above the
OS Mini LED
rear
module diamond plate kick
lights
STANDARD
Independence
Fire
Department
Page
7
Price
EXTERIOR COMPARTMENT CONSTRUCTION
30
1
4
Door Sill Protection
0
Install Stainless Steel sill protector
lower
on
edge of all
door frames to prevent paint
damage
STANDARD
EXTERIOR COMPARTMENT DOORS
8
2
4
Compartment Door Handle Manual Locks
All doors shall incorporate double cut
0
non
directional tumbler assemblies that
are
keyed alike
STANDARD
9
2
4
Module Compartment Doors Fitted
w
TriMark High Strength
Treated Steel Rotary
0
Latches
Rotary latches mounted
zinc
nylon lock
with
4
1
x
20 SS
tapered machine
screws
for flush fit with
nut
STANDARD
10
2
4
Nader Pins
TriMark
Installed through
High Strength
jamb
Zinc Plated Steel Nader Pin
w
Compression
Washer
0
extrusion into blind fastener
STANDARD
12
2
4
Lubricate all Door Hardware
All
paddle handles latches rods
0
and
springs shall be lubricated prior to delivery
STANDARD
13
2
4
All exterior compartment doors shall have
lower outboard
corner
a
red reflector
mechanically attached
to the
0
of the door
STANDARD
20
2
4
Hidden Hinge Compartment Door Seal
0
on Door
Module exterior compartment door jambs to be extruded aluminum The flange that
overlaps
Independence
Fire
the exterior wall skin to be
Department
tapered
to meet the
body skin The compartment
Page 8
Price
doors to be double box pan formed
planking insulation between the
secured to the door
so
configuration
with Expaned Polystyrene foam
outer skin and inside pan Weather
stripping to be
that the latching system is protected from the elements The
door hinge to be hidden behind the exterior door skin
The interior door
panels shall have Scorpion TM polyurethane rubberized coating
applied
STANDARD
23
2
4
Gas Struts
on
Compartments
Install Heavy Duty pnuematic gas shocks Install
0
1
strut
on
each door
STANDARD
EXTERIOR COMPARTMENT INTERIOR
10
4
Exterior
Compartment Interior Scorpion Rubberized Liner Color Choice
Scorpion rubberized polyurethane coating applied
to the
0
surfaces of all exterior
compartment walls and dividers
Does not include slide out
battery tray Battery tray
to be
raw
aluminum
STANDARD
10
4
Black
00
10
450
4
EXTERIOR COMPARTMENT SHELVING
1
5
4
Diamond Plate Exterior Compartment Shelving
0
STANDARD
1 COMPARTMENT
11
6
4
1
Compartment Electrical Storage
Recessed into the bulkhead side of compartment 1 shall be
0
an
enclosed
installation of miscellaneous electrical components The aluminum
cover
be installed with J moulding The J moulding to be full length of panel
area
for the
for this
on
area to
bottom and
inboard side Outboard side of panel to be secured with mechanical fasteners
STANDARD
Independence
Fire
Department
Page
9
Price
12
6
4
1
to be the
Compartment
forward most compartment
on
the street side of the
module This compartment shall be for oxygen storage It will be
stamped
louvers and contain
a
a
0
vented with
universal oxygen cylinder holder to fit standard 6 to 9
bottles Compartment shall also include
the forward side and
externally
fixed divider providing backboard storage
a
fixed shelf above the oxygen
area
on
for miscellaneous storage A
wrench shall be tethered inside the compartment
cylinder changing
STANDARD ULTRAMEDIC
2 COMPARTMENT
6
7
4
2
Compartment
action
shelf
area
to be
on
directly behind the
0
1 compartment and below the interior
the street side of the module includes 1
adjustable
shelf
on
Unistrut track
STANDARD Ultramedic
31
7
4
Increase
2
Height
height of the
Increase the
interior action
area
00
150
Compartment 6 Inches
2 compartment 6 inches Includes
countertop and
counter
raising the height of the
aft of CPR seat
4 COMPARTMENT
30
9
4
Full
Height
4
Compartment streetside
rear
of module with Interior Upper left 4
0
Cabinet
4
Compartment
to be full
height
to bottom of upper left 4 cabinet
Compartment
1 adjustable shelf
includes
STANDARD
80
9
4
00
100
Unistrut Back Wall of 4 Compartment for SCBA Brackets
Install Unistrut
on
upper
portion of back wall inside the
4 exterior compartment for
installation of SCBA brackets Includes 8 nuts and bolts for Unistrut
6 COMPARTMENT
11
4
6
6
Compartment
curbside
rear
installed
on
Independence
Fire
to be a full
height backboard storage compartment located
of the module Includes
one
full
height adjustable
0
at the
divider with Turtle tile
compartment floor
Department
Page
10
Price
STANDARD ULTRAMEDIC
11
4
30
Increase
depth
to 48 at 6
of exterior 6 compartment 2 for stair chair
storage Reduce aisle width
compartment only There will be
a
00
230
jog from the 6 to the face of the squad
bench Standard 50 aisle width is maintained forward of the 6
compartment
Install 16 x 26 L bars on the rear doors to allow for increased
of 6
depth
compartment Stair Chair
This option
11
4
451
for 50 aisle
1 Adjustable
to be a
only
shelf for exterior compartment 6 Shelf to be installed forward of the
fixed vertical divider Includes
11
4
463
11
4
463
Equipment Strap
6
1 Restraint Strap
There shall be
installed
Stryker
model 6252
Compartment
in 6
0
Compartment
1 equipmentbackboard
across
00
190
adding 1 additional compartment light
00
50
restraint straps with
quick release buckle
the opening in Compartment 6 from left wall to divider
5 COMPARTMENT
6
12
4
34
Add 5
6 Compartment curbside of
module aft of wheelwell
00
620
Ultramedic Promedic only
8 COMPARTMENT
14
4
14
A
Style
8
Full
Height
Compartment
door allows
8
Compartment
to be
access to
full
0
height to bottom of locking drug cabinet Compartment
the interior ALS cabinet The interior ALS cabinet to include 2
adjustable shelves
STANDARD Ultramedic Promedic
INTERIOR CABINET CONSTRUCTION
19
1
5
Restocking
Door Frame Felt Track
Slam Latches
All upper band cabinet door frames to consist of rigid
glass frame The rigid design of the frame
Independence
Fire
Department
0
heavy duty extruded aluminum
extrusions and
corner
assemblies
on
the
page
11
Price
restocking
doors will reduce
twisting of the frame
held closed with slam latches and the felt track
structure The door frames will be
design does
not
require adjustment
STANDARD
20
1
5
Stainless Steel Slam Latches
w
Pull
Ring
0
Southco 2 Round Stainless Steel Slam Latches to be installed
Includes Left Stack
Right
on
all hinged doors
Stack and Bulkhead Electrical Cabinet
STANDARD
22
1
5
Interior Cabinet
Seal all open
Seams Sealed
seams to
0
prevent fluid borne pathogen contamination
STANDARD
23
1
5
New Interior Trim
0
All cabinet and wall
panel aluminum trim
to be
Gray anodized No Black trim
to be
used
All
protective
corner
trim will be
Opaque and will include
a
matching domed end
cap
STANDARD
24
1
5
Restocking
Door Hold
Open Assist
5
Upper Left Cabinets 2 2
0
4 to have
restocking
feature
STANDARD
HEADLINER
11
6
5
Medical Device Rail
Ceiling
Install
a
surface mounted Medical Device rail system
the track will have
entire
0
an accent
stripe
length of the module with the sole
medical personnel to quickly
medical device rail allows for
focused at head torso and
See separate
access
the primary cot Each side of
intent of
providing easy
equipment for administering
previsions
for standard
legs and 2 antenna
options for additional
over
The track system to be surface mounted and
IV
hangers
1
IV
accesses
access to
aid to the
run
the
allow the
patient The
Hanger 3 Patient Lights
under cot
lights
oxygen outlet and AM FM
speakers
STANDARD
Independence
Fire
Department
Page
12
Price
12
6
5
Patient compartment
backing
and
ceiling
no seams
to be a seamless White
vinyl headliner with foam cushion
0
This soft ceiling shall provide additional safety and insulation
STANDARD
FLOORING
30
7
5
Lonplate
30
7
5
Gunmetal 424
II
Flooring Choice
0
00
210
GRAB RAIL
10
5
21
72 Antimicrobial Stainless Steel Grab Rail Streetside
72 inch Antimicrobial Stainless Steel
addition to standard
ceiling grab
00
170
grab rail mounted stretside of primary
cot In
rail
PLASMA HANGER
11
5
40
2
CPI 2008 IV Hangers
0
Flush mount in the ceiling
over
the torso
area
of the
primary
cot and
squad bench
STANDARD
11
5
57
2
CPI mini
spring clip
IV
hangers
IV2001 in addition
to standard
00
70
SPECIFY EXACT LOCATION
LEFT STACK AREA 1
12
5
20
Upper Bulkhead Electrical Cabinet Double
Install double
hinged
right hand door and
Doors
doors with stainless steel
center mullion
on
0
locking
slam latch with pull ring
the left hand door
on
on
the
the standard upper
bulkhead electrical cabinet
STANDARD
12
5
25
Left Stack Radio Inverter cabinet to include
sections shall have double solid
Independence
Fire
Department
1 adjustable shelf in
aluminum Wilsonart
upper section Both
0
covered doors with Stainless Steel
Page
13
Price
locking Slam
Latch with Pull
latch with pull ring
on
Ring
on
the upper doors and stainless steel
non
locking slam
the lower doors The stainless steel slam latches to be installed
the right hand doors with
a
on
center mullion on the left hand door
STANDARD ULTRAMEDIC
12
5
500
SPECIAL
keypad
Install
as
a
RCI
3513 electric lock in the upper left stack Lock will
use
the
00
300
same
lock in the U8 cabinet Note Both locks will work in conjunction with each
other
ACTION WALL AREA 2
13
5
7
Action Wall Medical Device Rail
Install
an
track will have
system
0
action wall Medical Device rail system
a
solid surface accent
stripe
on
the streetside wall Each side of the
to match the action wall counter The track
to be surface mounted and run the entire
Length
of the action wail from the 1
to the CPR seat
compartment
The medical device rail allows for previsions for the standard
2 Oxygen Outlets Oxygen
Solenoid Valve Suction Regulator 12V Outlet and 110V Outlet
STANDARD
13
5
17
Center Left 2
Cabinet Forward
Action Counter
00
450
Center left 2 cabinet on forward action wall counter with double
2 round
W
24
x
2 round
13
5
22
x
non
stainless steel latches and
Lexan
doors
2 adjustable shelves Approximately
7 in D
locking stainless steel latches
Avonite Solid Surface
area
13
5
22
locking
non
H
24
hinged
Includes full
Countertop installed
perimeter retaining Hp
on
on
forward action
area
and
rear
0
monitor
both sections
Color to be Avonite Stormy Gray F1 9010
0
STANDARD
13
5
262
Relocate SSCOR Suction Canister Lower Left
SSCOR Suction canister and
the action
Independence
Fire
area
counter
Department
mounting bracket
00
190
to
be relocated to recessed
area
below
just forward of the CPR seat The suction regulator is to remain
Page
14
Price
on
13
5
500
the action
area
wall
5 Cabinets Due to the
Custom Upper Left 2 and 2
SPECIAL
compartment and the 24 high cabinet
cabinets will be reduced in
controls to be built into
a
heights by
on
height of the
the aft end of the action counter these
The attendant switch
6
00
220
2 exterior
panel and environmental
separate 6 high section running the full length below the
5 and tilted
upper left 2 and 2
slightly
down for
ease
of
accessibility
to the attendant
STREETSIDE C P R SEAT AREA 3
14
5
0
Streetside CPR seat
The CPR seat shall include
a
flip
up seat
equipped with
a
gas strut hold open device
and positive latch for securing the lid when closed The CPR seat to include
seat and
backrest the upper and lower sections will be
padded
on
a
2 foam
both sides for added
protection
STANDARD All Models Excluding Duramedic
14
5
500
Increase width of CPR seat aft 5 and install a lower 3 cabinet with
SPECIAL
adjustable shelf and sliding plex door
00
360
1
Counter aft of CPR seat will be 5 includes wide
CPR seat will be 32 wide
14
5
5000
Custom upper 3 cabinet
SPECIAL
clear
approximately
37 W
x
12 H Cabinet to have
an
11
00
450
depth
SQUAD BENCH AREA
16
5
45
Squad Bench Medical
Install
a
squad bench Medical Device Rail system
track will have
system
0
Device Rail
to be
a
on
the curbside wall Each side of the
solid surface accent stripe to match the action wall counter The track
surface mounted The medical device rail allows for previsions for the
standard Oxygen Outlet and Ceiling Light Timer
STANDARD
16
5
50
Curbside
A
Independence
Squad Bench with
squad bench shall be
Fire
Department
Seat Belts for
provided
on
0
3 People
the curbside with seating for Three people
Page
15
Price
Includes
a
supports
two
on
piece hinged lid for internal storage and will have pneumatic lifting
each side
STANDARD
16
5
82
Overhead Squad Bench Cabinet
Cabinet to be
Non KKK
1D
Approximately 8 2
mounted at ceiling level and include
x
2
compliant
12 H
x
sets of
00
640
length of squad bench Cabinet to be
sliding Acrylic doors
and
restocking
feature
NOTE Does not meet KKK F for distance between
top of
of cabinet cushion
squad bench cushion
to
bottom
BIOHAZARD
17
5
2
A
Style
Grab Bar Arm Rest Anti Microbial with Waste
Sharps
Anti Microbial Stainless Steel Grab
built in holders for
5
a
5 quart
Sharps
quart Sharps Container and
A Bar may be pivoted
an
Arm Rest
Bar
Container and
an
0
head of the squad bench with
8 quart Waste Container Includes
8 quart Waste Container
removed for patient
or
at the
care
STANDARD
17
5
210
Glove
17
5
500
Waste and
Butler 3 Over Curbside Entry
Sharps
Access
00
370
Through Top of Squad Bench
Combination Waste and Sharps storage
Sharps to
be removable
through the lid Lid
to
through
have
a
a
area
00
370
at head of
squad bench Waste and
lift up RED LEXAN lid with disposal
2 round
access
holes cut
locking Stainless Steel pull ring slam latch
non
Includes 8 quart waste container and 8 quart top loading sharps container Model 8970
Rotary Lid
CURBSIDE RIGHT STACK STORAGE 8
18
5
6
Top right stack above the ALS drug cabinet
Conditioned air shall be distributed
of the
Independence
ceiling
Fire
There shall be
Department
a
to
through
include
six vents
a
heat
C
A
unit
evenly spaced
down the full
0
length
floor to ceiling plenum with intake vents of sufficient size
Page
16
Price
to allow recirculation of the conditioned air
STANDARD Ultramedic Promedic
18
5
8
Stack Hidden Air Intake
Right
The
0
right stack Air Intake Chamber to be
and will include
a
hidden
opening
an
extension of the inboard
right stack wall
at the bottom for recirculation The air intake to be
elevated from the floor to allow for
cove
moulding
and roll up
flooring
STANDARD
18
5
10
A
Style Right
Stack ALS
Upper section
to be a
w
Lower Cabinet
Locking Drug Cabinet with
Lower section to have framed
Steel
or
pull
0
a
single aluminum drop down door
8 Lexan doors with 2 Round
3
ring slam latches and
2 adjustable shelves that have
non
locking Stainless
access
from the interior
exterior
STANDARD Ultramedic Promedic
18
5
61
RCI Electric 3512
w
Remote
Keypad Lock for Hinged Right Stack
00
450
ALS Door
Install RCI Electric 3512 cabinet lock with RCI Electric 93251 Keypad wired direct to
battery
SPECIFY LOCATION
18
5
500
SPECIAL
The U8 cabinet to have
an
opening of 13 high
00
90
ATTENDANT SEAT
19
5
55
EVS
vacuum
formed Attendant Child seat mounted
on an
0
EVS185 2 two position
swiveling base
19
5
55
EVS seat to be Gunmetal
00
220
INTERIOR COLORS
20
5
51
Laminate color choices
Independence
Fire
Department
0
Page 17
Price
20
5
51
Wilsonart Dove Gray Matte Finish D92 60
0
STANDARD
NOTE
Replaces Matte Fog 961 58
20
5
53
Upper Band Vinyl Color Choice for cabinets and stitched cushions
20
5
53
Ash Gray
20
5
55
Vacuum Formed Lower Band Vinyl Color Choice
0
00
110
0
All lower band seat cushions and back rests to be
vacuum
formed
Includes Squad bench seats squad bench back rest CPR seat CPR backrest and hip
cushions
20
5
55
Gunmetal
20
5
90
All interior
0
sliding
doors shall be 3
16 standard
All interior framed and
hinged doors
to be
8
3
Acrylic
0
Lexan scratch resistant
STANDARD
20
5
90
Color to be CLEAR
0
STANDARD
MISC INTERIOR OPTIONS
21
5
70
Inside Outside Access 6
Inside Outside
door with
2
access to
2 Round
Compartment
w
Hinged
the 6 compartment A single
non
The door will extend from the
level of the
squad bench
Exterior shelf retaining
See
to be
aligned
Lexan
to be located on
the aisle
facing
highest possible point of the compartment down
lids and will be
Hp
8
hinged framed 3
locking Stainless Steel pull ring slam latches
the forward portion of the 6 compartment
00
370
Lexan Door
to
the
approximately 84
2 wide
with door
opening
11 for fixed divider NOTE Increase
4
option 456
to 11 1
2 W with
option for 6
wider compartment
Ultramedic Promedic Only
Independence
Fire
Department
Page 18
Price
21
5
500
SPECIAL
Install
non
locking
patient compartment
to
mini
seat lid
paddle latches
TBN 48 SS in lieu of standard for all
positions There shall also be anodized aluminum
00
40
covers
protect the back sides of all latches
COMMUNICATION
15
6
2
RG58AU Low Loss Antenna Cables
0
Install 2 antenna cables Cables to route from the module roof to the lower section of
the Left Stack Radio Cabinet and be of sufficient length to allow routing to the Cab
Console as an alternate radio installation location Cables to have a service loop and be
secured to the module roof structure accessible
labeled
at both ends
by removing
an
interior
light
and
This option does not include connectors
STANDARD
16
6
Two
Way Radio Routing Path Cab
Provide
a
routing path for
to Module
0
customer installed radio cables from the radio
the cab floor console and or from the cab floor console to the
rear
cabinet to
action wall
STANDARD
17
6
Two
Way Radio Prewire
12VDC 8 gauge Power and Ground
The Black ground wire shall be connected
shall be left unconnected
route to the lower section
near a
to a main
0
ground point the Red
power wire
direct to battery connection point Both wires shall
of the Left Stack Radio Cabinet and be of sufficient length to
allow routing to the cab console
as an
alternate radio installation location Wires shall
be labeled at both ends
STANDARD
61
6
2 Additional
8 gauge 12V power and
ground wiring pairs
The Black ground wires to be connected to
to
be left unconnected
near a
direct to
a
battery
main
ground point
connection
00
90
the Red power wires
point inside the
power
distribution cabinet All 4 wires to route to the lower section of the Left Stack Radio
Cabinet and be of sufficient length to allow routing to the Cab Console
as an
alternate
radio installation location Wires to be labeled at both ends
Independence
Fire
Department
Page 19
Price
100
6
Audiovox
ASA
Voyager VCCS 150 Color back up Camera
Camera mounted exterior
monitor
on
the
over
rear
front console Wire to turn
See option 8
42 for Smart
4
Display
00
350
entry doors and connected
camera on
II with video
when vehicle is
to
Smart
placed
in
Display
II
reverse
inputs
RADIO AND CLOCKS
54
7
6
Trintec 12
24 Hour Clock Battery Powered Over Rear Doors
Trintec 6 inch dry cell battery operated electric
hour
24
12
second
74
7
6
hand recessed in cushion
over rear
80
analog clock with
sweep
doors
Speakers Mounted in Ceiling
w Volume Control in Action Wall
Patient compartment AM FM radio speakers
2 recessed in ceiling with
control in action wall
00
220
rear
volume
BATTERY SYSTEM
53
4
7
Program the battery shut off circuit
to remain on for
approximately 5 minutes after the
ignition has been shut off Shutting off the ignition will activate a timer that will leave
the batteries
left
on
on
for
approximately five
for patient unloadingvehicle
minutes
so
that the module dome lights
can
0
be
restocking
STANDARD
500
4
7
SPECIAL
which is
Delete
a
3 standard Delco
1150 batteries and install Deka Model
1231 MF
BATTERY CHARGER
1
5
7
60
9
7
0
Batteries Ford Type
III and
Battery Charger
Prewire
Install 12 gauge
wiring
Chevy
only
to
a
CG3300
3 700CCA AC
Delco
12V
20 Amp circuit that is
originating from the Shorepower
to
the Lower Left StackRadio Compartment
NOTE This option does not include a
battery changer
STANDARD
Independence
Fire
00
190
threaded post
Department
Page 20
Price
12VDC OUTLETS
10
7
10
2
12V Power Point
1
Style
outlets
In the forward action wall and
Plenum wall
1
Wired On with Ignition
at the
top of the Right Stack ALS cabinet
on
the
Circuit includes medical isolator
STANDARD
FRONT CONSOLE
15
1
8
Vacuum Formed Floor Mount Console
0
Cab floor console accommodates Switch Panel
1
Siren and
Radios Siren mounted in top portion Remainder of face
3 Communication
plate left blank
for radio
installer
STANDARD E350
E450
POWER DISTRIBUTION
37
4
8
Module wiring harnesses to be routed below the roof radius extrusion and will be
secured to the wall tubes Cabinet backs and cushions to be removable for
to the
access
s
harness
STANDARD
42
4
8
Smart
Display II Multiplex System
System
LCD VGA Screen
on
front switch panel
to include sealed Micro Touch Membrane Switches and electro
backlighting
screen
w
in the Front and Rear Switch Panels The front panel to include
and the
rear
panel
RegulatorTransducer
to include a
Mounted in 1
digital
400
2
00
luminescent
clock and thermostat Includes
an
an
LCD VGA
02
Compartment
INCLUDES VIDEO INPUTS FOR CAMERA OR GPS
NOTE The
shut off
battery
shut off circuit to remain
on
Shutting off the ignition will activate
five minutes
so
that the module dome
lights
for 5 minutes after the ignition has been
a
can
timer that will leave the batteries
be left
on
on
for
for patient unloading vehicle
restocking
Independence
Fire
Department
Page
21
Price
SIREN SPEAKERS
1
3
9
AIR HORNS
Cast Products SAD P4319
speakers recessed through bumper
0
STANDARD E350
E450
25
3
9
Siren Whelen 295SLSA1 STANDARD
Whelen Hands Free self
diagnostic
0
siren with NC
microphone and
17
programmable
Scan Lock siren tones
STANDARD
100
3
9
Air
Horns Dual Buell Front Bumper
2
310
1
00
12 inch Buell Strombos Airhorns mounted
OEM front
bumper Includes
through the plastic
air tank with a manual
pull
lower portion of the
cable spitter valve 12V pump
mounted in 2 compartment and Linemaster treadle foot switch for the driver
Airhorns will be On with Master NOTE Pump to include protective
cover
Ford E series
LIGHT BAR
17 LI
4
9
Front 90
183
4
9
Whelen Low Profile TAL85 47 with
Light Bar Whelen 4500FL Custom
8
LED
490
1
00
5MM LED Traffic Advisor mounted above
00
730
rear
doors with control head in radio console
NOTE The Traffic Advisor shall be wired
75
4
9
SPECIAL
directly to
the batteries
Whelen 4502LR82 90 Rear Linear LED light bar 4 Red Super LEDS 2 Clear
070
2
00
Super LEDS 2 Amber Super LEDS and 2 Halogen Load Lights
BACKUP ALARM
2
5
9
Back up alarm
electric 97 decibel with
automatic reset switch
0
STANDARD
EMERGENCY SEQUENCERLOAD MANAGER
2
6
9
0
Emergency Sequencer Load Manager
Incorporates
Independence
Fire
a
built in sequencer that turns
Department
on
and off the emergency loads
at
Page
22
Price
half second intervals A built in electrical load manager will be preprogrammed
shut down non essential pre selected loads in
priority order as needed to maintain
one
sufficient
charge
STANDARD
in the 12VDC system
FLASHERS
DRIVER SIDE
52
9
13
Driver side flashers
1
to
2 Whelen
in the upper forward and
1
900
Super
LED with internal flashers
in the upper rearward
corners
52
9
13
Color Red
FLASHERS
PASSENGER SIDE
54
9
13
Passenger side flashers 2 Whelen 900 Super LED with
w
chrome flanges
0
of the module
00
290
internal flashers
w
chrome
0
flanges
1
in the upper forward and
54
9
13
Color Red
FLASHERS
REAR
56
9
13
Rear module flashers
Upper outboard
56
9
13
1
in the upper rearward
corners
of the module
00
290
2 Whelen
900 Super LED with internal flashers
0
corners
Color Red
00
290
REAR WINDOW FLASHERS
58
9
33
Lower window flashers
2 Whelen
900 Super LED
warning lights
with internal flashers to show though the lower portion of the
58
9
33
w
rear
chrome flanges
0
door windows
Color Red
00
500
GRILLE LIGHTS
independence
Fire
Department
Page
23
Price
60
9
47
60
9
47
Grille lights shall be Whelen 500 Series LING
Super LED
Color
Red White Split White
INTERSECTION LIGHTS
62
9
13
62
9
5
13
0
to face forward
00
250
MODULE
Wheel Well Intersection Lights
Mounted above the
64 1
9
13
Whelen 700 Super LEDs with internal flashers
Red White Split White
INTERSECTION LIGHTS
64
9
13
to outside corners
CAB
Cab Intersection Lights
Color
00
250
rear
2 Whelen
700 Super LEDs with internal flashers
0
wheel wells
Color Red White Split White to outside
corners
00
440
EXTERIOR AUTOMOTIVE LIGHTING
20
1
10
Rear flashers wired to brake
Uppermost
rear
lights
0
outboard Red flashers to be wired to OEM brake
NOTE Flashers will NOT function
as
brake Tights when
lights
Emergency Lights
are
flashing
STANDARD
23
1
10
Whelen OS Mini LED Marker and Clearance Lights
2 Amber upper forward markers
2
Red upper rearward markers
5 Red
4
0
rear
clearance lights
Red beltline side marker and turn signal
STANDARD
26
1
10
2
Turn
Signals 2 Brake LED Indicators in Cushion Over Rear
LED turn
rear
LED brake
Doors
Tight indicator
on
Install
Fire
These
lights will have chrome bezels
Department
2 Amber
the cushion
doors to inform personnel in patient compartment when the vehicle is
braking
Independence
signal indicators and 2 Red
Does not require any
over
00
200
the
turning and
plaques
Page
24
Price
71
1
10
Front turn
signals Whelen
600 LED
00
340
Model 600 LED Amber populated Arrow Turn
Signal lamps with chrome flanges
mounted upper front of module
500
1
10
SPECIAL
amber
lights
Rear brake tailturn
arrow
turn
to remain
Whelen 600 series LED brake max
signal lamps
halogen
on
the
rear
Note Brake tail
population tail
and
00
270
of the module in lieu of standard Back
up
light exceed SAE requirements
FLOOD AND LOADING SYSTEMS
20
2
10
Side
Scene
Rear load and Back Up
Light Operations
0
The upper curbside Scene
The upper
rear
doors
rear
are
Lights will operate when the curbside entry door is opened
Load Lights and the lower Back Up Lights will operate
together when the
open
or
when the vehicle is placed in
The streetside and curbside Scene
separate switch
a
on
placed
rear
Load
Lights will also operate from
the front console
Note When mod power is
vehicle is
lights and the
reverse
off only the lower back up lights will operate when the
in reverse
STANDARD
40
2
10
Additional Whelen halogen side
Add center
scene
light 1
on
scene
lights
00
170
each side of module
MODULE INTERIOR LIGHTING
10
1
11
Restocking Timer
A
momentary switch
to be wired direct to
battery through
a
60 minute timer to
operate the Module Dome Lights while the vehicle is Off This feature will enable
clean and restock the vehicle but eliminates the risk of
leaving the lights
the
batteries
The
draining
momentary switch to be located on the curbside wall
personnel
on
and
near
to
the side entrance door
STANDARD
17
1
11
Whelen 8 Round LED Dome
This option is for 11
Independence
Fire
Department
lights
Lights
ILOS
280
1
00
total
Page
25
Price
Ultramedic Promedic
54
1
11
Dome Lights
3 Whelen 86
HiOffLo
3 Additional Whelen 86 series high intensity patient checkout lights in
ceiling of
module over primary cot with
separate 12V Hi OffLo switch in rear switch
00
310
panel
Wired On with module
54
2
11
Spotlight
Guest
Guest Beamer Roof
Beamer
360 degree
Mounted 000
000
1
spotlight 500A
on
CP
00
730
cab roof 000
000 CP in lieu of
1
standard handheld spotlight Joystick control is hard mounted to
floor console Includes
the deletion of the standard hand held
spotlight Spotlight to be wired Ignition Hot
70
2
11
5
Streamlight Dual Filament Lightbox 5L45
81
2
11
Flashlight Streamlight Survivor
NOTE
81
2
11
1
00
140
110V
Replaces the discontinued
2 Streamlight Survivor Division
8 watt spot
2
SL 90
flashlights
Must choose option 2
11
9
2 for 110V
with 110V fast
chargers Orange
90043
00
260
wiring
SPECIFY LOCATIONS
92
2
11
Flashlight Wiring
0
92 Wiring for 3 Flashlights 110 Volt hardwire
2
11
00
190
SPECIFY LOCATIONS
EXTERNAL 110VAC SHORE POWER
61
1
12
Kussmaul Auto Eject shoreline inlet in ILOS 15
amp shore White
80
1
12
1 Shore Indicator ON Green Indicator Light
Install a waterproof Green LED indicator
light above shore power inlet Wire after
00
240
00
100
GFI
breaker to indicate shore power is ON and GFI breaker has not
tripped
Independence
Fire
Department
Page 26
Price
2
12
Interior 110V 15A Hospital Grade
Duplex Receptacles
1 In the forward action wall and 1 at the
of lower
top
Right StackALS Cabinet
on
the
plenum wall STANDARD
52
2
12
53
2
12
53
2
12
1 Additional illuminated interior 110VAC15AMP duplex
receptacle located
squad bench at the rear
Additional illuminated interior 11OVAC15AMP
2 Additional illuminated
over
the
duplex outlets
interior 110VAC15AMP
00
170
0
duplex outlets
00
300
SPECIFY LOCATIONS
ONBOARD 110VAC POWER SUPPLY
110
3
12
Inverter Pre Wire
Wiring only for 1200
0
watt maximum UL
listed inverter with internal transfer relay and
Wiring setup is for inverter installation in bottom section of Left
battery charger
StackRadio Cabinet Includes
remote
on
off switch
in the
rear
switch panel
STANDARD
122
3
12
Vanner 1050 Watt Inverter55 amp
Charger Charge Indicator
Vanner UL listed 1050 watt inverter55
amp
internal transfer relay Includes
on
Console
130
1
00
battery charger 20 1050CUL with
battery charger indicator
mounted
on
driver side of
radio console
AUXILARY ENVIRONMENTAL SYSTEMS
500
2
13
SPECIAL
Exhaust fan 230 CFM
high output 2 speed exhaust fan
in lieu of 100 CFM
00
60
COTS AND COT FASTENERS
20
1
14
Cot
Mount Stryker 6377 Dual Position ILOS
Stryker 6377 dual position cot fastener for a Stryker
00
130
cot in
lieu of standard
OXYGEN AND AIR SYSTEMS
Independence
Fire
Department
Page 27
Price
30
2
14
02 Solenoid Valve and Manual
by pass Installed on Action Wall
Electric 02 low pressure control
system with solenoid behind a faceplate
wall The same face plate to be utilized for the
manual
valve
0
on
the action
bypass
Includes
12VDC switch
a
on
the
switch panel
rear
STANDARD
31
2
14
Ohio 02 Outlets
2
Action Wall
1
at
Head of Squad Bench
0
STANDARD
45
2
14
Install
single additional 02 outlet
a
per the customers
requirements
00
140
SPECIFY LOCATION
72
2
14
02 Gauge 3000 PSI
on
3000 PSI dial type
high
installed
High
on
1 Wall
00
130
pressure gauge for oxygen system tank pressure
wall of 1 compartment
pressure hose to be secured
so
as
high
as
possible
the stress is
on
Gauge
to allow removal of oxygen tank
the hose and not the back of the
gauge
For
172
2
14
PC Electrical system this
install 2 SCBA bracket
on
option requires addition of
adjustable
a
50 PSI 02
regulator option
Unistrut track in exterior compartment
00
290
SPECIFY LOCATION
NOTE Zico WALKAWAY
this
Spring Clip Bracket
option If bottles intended for
use
UN 6 30 3 SF is
supplied by default for
in this vehicle will not fit this
bracket
SPECIFY
EXACT ZICO MODEL NUMBER that should be installed Model numbers other than the
default may affect option pricing
500
2
14
SPECIAL
as
much
Action wall 02
as
outlets 02 solenoid and manual by pass
possible leaving 12 from outlets to 110V outlet
to be moved forward
0
VACUUM SYSTEM
40
3
14
SSCOR On Board Suction System
0
SSCOR suction system with wall mounted
and associated
Regulator
Independence
Fire
to be
tubing
on
action wall Includes On Off switch
plumbed directly
Department
regulator canister
Lexan
on rear
holding bracket
switch
panel
to the canister
Page
28
Price
STANDARD
MISC MEDICAL
2
4
14
Ship Loose 1
5
ABC Fire extinguisher with mounting bracket
0
STANDARD
NOTE Must order
required
1 Additional
5
ABC
Fire
extinguisher with mounting bracket if
to meet KKK F
PAINT AND FINISH
30
1
15
Base paint solid
single color with
a
Certified PPG Delfleet System paint
process White
to match OEM Chassis
The entire exterior surface of the module will
be sanded with
paper and then buffed using 3M Perfect lt HI
a
buffing compound
minimum 1200 grit sand
to
provide
gloss final surface finish
a
clean high
STANDARD
NOTE Beltline Paint
or
Scotchlite stripe is optional
PAINT AND SCOTCHL
TE DESIGN
51
2
15
2 Pinstripe Applied
1
to Paint or
Stripe Edges
NOTE Pinstripe applied to stripes that are close
together will alter the spacing between
those stripes If stripe spacing is critical in
your design please specify critical
measurements of distance
s between stripes after
is
pinstripe
51
2
15
applied
Reflective Red 680 72
Independence
Fire
Department
00
290
Page
29
Price
51
2
15
500
2
15
Reflective Red 680 72
SPECIAL
00
290
Custom paint stripe
Please
see
previous unit 5960 photos
center
stripe
is
32 wide The beltlines is 14 wide Paint code is
FLNA3042 RED
600
2
15
40
3
15
SPECIAL
Outline paint stripe with 1
2 blue scotchlite positioned 1
2 from red
scotchlite
on
applied
to inside the curbside
rear
entry door Add the Model Name
the 4 and 6 compartment door
NOTE
STANDARD
2
1
16
00
630
paint stripe
Road Rescue Logos
on
740
1
00
s Manual
Owner
Ambulance and Star of Life decals
are
0
optional
STANDARD
Lettering and Chevron Striping per Customer Specification
000
2
00
Total Cost of Ambulance
Ford Rebate
00
910
147
Total Cost of Ambulance after Ford Rebate
700
4
00
00
210
143
Independence
Fire
Department
Page 31
If Independence Fire wishes to trade in their 1999 Wheelcoach
500 from
5
00
Ford Motor
the above
Company
is
Freightliner please
deduct
quoted price
currently offering
a
700 rebate subject to change
4
00
on
2010
model year chassis for eligible departments This dollar amount will be sent to
Independence Fire Department from Ford after receipt of FIN code and delivery of vehicle
This unit carries
a standard chassis warranty a 3 year36
000 mile conversion warranty a
lifetime structural warranty not limited to a number of years on the module a 7 year70
000
mile warranty on the factory conversion electrical wiring system and a 5 year100
000 mile
warranty
on
the
paint
Delivery of unit would be approximately 180 220 days after receipt
signed production
drawings order whichever occurs last
in full is due upon delivery Please call
1 800 541 9518 Thank you
Payment
me
of chassis and or
if you have any
questions
receipt
of
at
Sincerely
Burgess Arnb clan Sales
Inc
z
k
b
Sales
Burgess
Manage
Independence
Fire
Department
Page
31
Download