Catalog Number Notes FEATURES & SPECIFICATIONS Type RELOC®-Ready Luminaire INTENDED USE The RELOC®-Ready Luminaire (RRL) connectors enables a simple and consistent factory installed option across all ABL luminaire brands. When ordered on a RELOC fixture cable, cord drop, drop cable, power tee; the line side of the connector will be factory attached to all the wire leads except for the ground wire. When ordered with the luminaire, the load side of the connector will be prewired based on the appropriate wiring instruction selection. Universal Fixture Connector RRL ELECTRICAL •18 AWG solid wire only; stranded not available. • Tin-bonded 18 AWG (≤16 strand) acceptable. •Current Interruption 10 cycles. SYSTEM FEATURES •RRL connector used with Quick-Flex®, System 820 and OnePass® systems. •Load side of connector factory attached to luminaire. Refer to luminaire spec sheet for ordering information. •4-pole mating connector with push-in terminations allows for simple installation. •Touch-safe design on both halves, meets UL/CSA requirement. •Wiping contact design allows safe disconnect under load. •RoHS Compliant WARRANTY LISTINGS •5-year limited warranty. Complete warranty terms located at www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx •UL 2459 •CSA- C22.2 NO. 2459 •NEC 2008 410.130(G) Compliant Actual performance may differ as a result of end-user environment and application. Note: Specifications subject to change without notice. •CEC 30-308(4) Compliant Load Side RELOC®-Ready Luminaire ORDERING LOGIC Line Side RELOC® Example: RRLA For shortest lead times, configure product using bolded options. RRL Series Series RRL RRL Wiring Instructions A B C AB AE ABE C12S 22N 122N Ballast/driver wired to pin position #1 (120V,277V,347V - Phase A) Ballast/driver wired to pin position #1 & #2 (208V, 240V, 480V - Phase A) Ballast/driver wired to pin position #2 (120V,277V,347V - Phase B) Ballast/driver wired to pin position #3 & #4 (208V, 240V, 480V - Phase B) Ballast/driver wired to pin position #3 ( 120V,277V,347V - Phase C ) 1 Outboard ballast/driver wired to pin position #1 (120V,277V,347V - Phase A) Inboard ballast/driver wired to pin position #2 (120V, 277V, 347V - Phase B) Outboard ballast/driver wired to pin position #1,#2 (208V, 240V, 480V - Phase A) Inboard ballast/driver wired to pin position #3,#4 (208V, 240V, 480V - Phase B) Ballast/driver wired to pin position #1 (120V,277V,347V - Phase A) Emergency ballast/driver wired to pin position #2 (120V,277V,347V - Phase B) 2 Ballast/driver wired to pin position #1 (120V,277V,347V - Phase A) Ballast/driver wired to pin position #2 (120V,277V,347V - Phase B) Emergency ballast/driver wired to pin position #3 (120V,277V,347V - Phase C) 1,2 Ballast/driver wired to pin position #1 (120V,277V,347V - Phase A) Low voltage wire (positive/purple) (data1) wired to pin position #2 Low voltage wire (common/gray) (data2) wired to pin position #3 1,3 Ballast/driver wired to pin position #1 & #2 (208V, 240V, 480V - Phase A) 1,3 Low voltage wire (positive/purple) (data1) wired to pin position #2 Low voltage wire (common/gray) (data2) wired to pin position #3 1,3 Ballast/driver wired to pin position #2 and pin position #3 (120V,277V,347V - Phase B) 1 Ballast/driver wired to pin position #1 and #4 (120V,277V,347V - Phase A) Ballast/driver wired to pin position #2 and #3 (120V,277V,347V - Phase B) 1 Example: QFC277 12/3G11 G RRL QSFC277 12/2G11 G RRL QPT277 12/3G09 RRL SSC 277 F U 11 G RRL OCS 480 10 RRL OD 277 12/3G 15 RRL NOTE 1. All hot conductors and neutral wires present in RELOC cable, drop cable or power tee. 2. G option required for QFC, QSFC, and SSC fixture cables. 3. Ground wire will include poke-in wire connector. 4. See RELOC spec sheets to order with RELOC systems. NOTES 1. RRLC, RRLABE, RRLC12S, RRL2N, and RRL122Noptions can not be used with the Quick-Flex system: QFC, QSFC, QPT, and QD. 2. AE and ABE Commercial fixtures should disconnect the TSPL before unplugging the RRL so it does not go into discharge mode. 3. RRLC12S option is to be used with the OnePass OD and 820 SSC, PT, and DC for 0-24V integrated single-circuit or 0-10V low voltage controls applications. RRL One Lithonia Way Conyers, GA 30012 Phone: 800-241-4750 Fax: 770-808-8650 www.relocwiring.com © 2013-2015 Acuity Brands Lighting, Inc. All rights reserved. Rev. 01/15/15 1 of 1 RRL RELOC®-Ready Luminaire DIMENSIONS Dimensions are shown in inches (millimeters) LOAD SIDE LINE SIDE Connects to Fixture. Installed on fixture at factory or by customer. Connects to RELOC Fixture Cable. Installed on Reloc cable at the factory. WIRING INSTRUCTIONS Pin position and conductor functions by voltage. Position # Function 1 Hot 1 2 Hot 2 3 Hot 3 4 Neutral Wiring Instruction Standard Wiring Applications 120V,277V,347V X X Function X 1 Hot 1 X X X 2 Hot 2 X X 3 Hot 3 4 Neutral X X X X X RRLA RRLB RRLC RRLAB Two Neutral Applications 120V, 277V, 347V Normal and Emergency Applications 120V, 277V, 347V Position # Wiring Instruction X X RRLAE RRLABE Function 1 Hot 1 X 1 Hot 1 X 2 Hot 2 X X 2 Data 1, Positive ( + ) X 3 Neutral 2 X X 3 Data 2, Common ( - ) X 4 Neutral 1 X 4 Neutral X RRL22N Special Industrial Voltage Applications 208V, 240V, 480V Position # Function 1 Hot 1 X 2 Hot 2 X 3 Hot 3 4 Hot 4 Wiring Instruction RRL122N Wiring Instruction RRLC12S Position # Function Class I Class II Wiring Applications 208V, 240V, 480V 1 Hot 1 X X 2 Data 1, Positive ( + ) X X 3 Data 2, Common ( - ) X X X 4 RRLB RRLAB X X RRLA Function Class I Class II Wiring Applications 120V, 277V Position # Wiring Instruction Position # X Hot 2 Wiring Instruction X RRLC12S RRL One Lithonia Way Conyers, GA 30012 Phone: 800-241-4750 Fax: 770-808-8650 www.relocwiring.com © 2013-2015 Acuity Brands Lighting, Inc. All rights reserved. Rev. 01/15/15 2 of 2