15 - TECHNICAL INFORMATION 488 Motor full load currents 489 DOL Starting Fuse links Circuit Breakers 490 491 Assisted Starting Fuse links GE Circuit Breakers GE Contactors 492 493 494 Auto Transformer Starting GE Contactors 495 Fire Pump Starting Fuse Links Circuit Breakers 496 497 Type 2 Coordination DOL Class 10 DOL Class 20 Star Delta 498 500 501 Transformers & Capacitors General Information Capacitor Protection Circuit Breakers Capacitor Protection Fuse Links Fuse Links TRx 502 504 505 503 Back Up Protection MCCB & Switch Fuses & MCB’s Circuit Breakers 506 506 507 Discrimination & Selectivity Fuses & Fuses Circuit Breakers 509 510 Enhanced Discrimination & Selectivity Circuit Breakers 516 Fuse Link Temperature De-rating 522 Protection of Cables with Fuse Links 523 GE Contactors for Lighting Circuits 524 Relay Equivalent Selection Chart 526 TECHNICAL Motor Protection - general information IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 487 MOTOR PROTECTION General In a circuit that provides power to a motor a number of protective & Control devices are normally present. The combination of these devices must be coordinated to ensure the efficiency & optimal protection of the motor. Here, the protection of such circuits strongly depends on the operational requirements, as the application for which the motor is used, the required starting frequency, required service level & applicable safety standards. Category Load type AC1 AC2 Non Inductive motor Slip ring motor AC3 Squirrel-cage motor AC4 Squirrel-cage motor (Cos phi = 0.45 <= 100A) (Cos phi = 0.35 > 100A) Trip Class 10A 10 20 30 1.2 x In t < 2 hours t < 2 hours t < 2 hours t < 2 hours Ir setting (min) Energization Starting Switching off while running Regenerative breaking Inching Energization Switching off while running Starting Switching off while running Regenerative breaking Pluging Inching Required tripping time at 1.5 x In 7.2 x In t < 2 min. 2 <= t <= 10sec. t < 4 min. 4 <= t <= 10sec. t < 8 min. 6 <= t <= 10sec. t < 12 min. 8 <= t <= 10sec. COORDINATION TYPE 2 TEST SEQUENCE Co ordination The standards require tests to define the co ordination between the protective & switching devices within the motor circuit. Depending on the state of the components after the test two coordination. Classes, 1 & 2 have been defined. The unique properties of the Record Plus breakers allow GE to offer solutions to meet the highest standard. Type 2 co ordination. Motor current Test with ie (AC3) current “r” Ie <= 16A 1kA 16 < Ie <= 63A 3 kA 63 < Ie <= 125A 5 kA 125 < Ie <= 315A 10 kA 315 < Ie <= 630A 18 kA After this test the original characteristics of the contactor and thermal relay MUST remain unchanged. After this test the short-circuit protection must trip within 10 ms at a fault current >= 15 x In Type 2 - Short-circuit test with current “Iq” <= 50kA This value which is generally 15kA is used to check the coordination of the device used in the motor starter circuit. For each combination with Record Plus™ breakers this value is mentioned in the following tables. After test with this current the following conditions must be met. No or minor welding of the contactors after testing; contact separation is simple and easy. The switchgear and controlgear are fully operational after test. IPD INDUSTRIAL PRODUCTS 488 Product Catalogue 2013 Phone: 1300 556 601 www.ipdgroup.com.au MOTOR PROTECTION MOTOR RATED OUTPUTS AND FULL LOAD CURRENTS Motor Rating kW 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 150 160 185 200 220 250 300 HP 1/8 1/6 1/4 1/3 0.5 0.75 1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 150 175 200 220 250 270 300 350 400 Full Load Current (A) At 415V At 440V At 1000V 0.4 0.38 0.5 0.47 0.6 0.56 0.8 0.75 1.1 1 0.46 1.5 1.4 0.63 1.8 1.7 0.76 2.6 2.4 1.1 3.4 3.2 1.5 4.8 4.5 2 7.6 7.2 2.7 11 10.3 4.6 14 13.2 5.9 21 19.8 8.8 28 26.4 11.8 34 32 14.3 40 38 17 55 52 23 66 62 28 80 75 33 100 94 42 135 127 57 160 150 67 200 188 84 230 216 97 260 245 108 280 264 116 320 301 134 350 329 147 380 357 160 430 404 181 510 479 214 TECHNICAL Notes: 1. Full load current values are nominal for standard squirrel-cage induction motors of rated speed 1500 rpm (4 pole). Possible deviation of FLC values ±10% depending on type and manufacturer. IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 489 MOTOR PROTECTION FUSE SELECTION FOR DIRECT-ON-LINE MOTOR STARTING Motor FLC (A) From 0 0.8 1.5 2.1 3.1 6.2 9.1 11.1 14.5 15.5 18.1 22.1 28.1 45.1 58 80.1 99.1 128.1 180.1 216.1 270.1 328.1 385.1 430.1 500.1 560.1 620.1 645.1 To 0.7 1.4 2 3 6.1 9 11 14.4 15.4 18 22 28 45 58 80 99 128 180 216 270 328 385 430 500 560 620 645 680 Recommended GEC, GE or IPD Fuse-Link Rating (A) Type T ‘gG’ Type T ‘gM’ DIN Type ‘gL’ - ‘gG’ 2 4 4 4 6 6 10 10 16 16 20 20 25 20M25† 25 32 20M32† 32 35 32M35 35 40 32M40 40 50 32M50 50 63 32M63 63 80 63M80 80 100 63M100 100 125 100M125 125 160 100M160 160 200 200 250 200M250 250 315 200M315* 315 355 315M355 355 400 400 450 400M450 500 500 500 560 630 630 630 670 630M670 800 710 800 750 1000 † Type NIT for 415V or less. * Type TF, if motor FLC does not exceed 200A and voltage is 500V or less. Notes: 1. Assumed starting conditions: Motor Rating Run-Up Up to 1kW 5 x FLC for 5 secs. 1.1 to 7.5kW 6 x FLC for 10 secs. 7.6 x 75kW 7 x FLC for 10 secs. Greater than 75kW 6 x FLC for 15 secs. Operating cycle of 2 starts in rapid succession and up to 8 starts per hour. 2. Suitable adjustments to the recommended rating may be necessary for: (a) Starting conditions in excess of the assumed starting conditions. (b) High enclosure (fluid environment) temperatures, refer to fuse de-rating information indicated on page 522. IPD INDUSTRIAL PRODUCTS 490 Product Catalogue 2013 Phone: 1300 556 601 www.ipdgroup.com.au MOTOR PROTECTION GE CIRCUIT BREAKER GUIDE FOR DIRECT-ON-LINE MOTOR STARTING 415V APPLICATIONS Motor Rating kW 0.37 0.55 0.75 1.1 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 150 160 185 200 220 250 300 315 335 375 400 FLC (A) 1.1 1.5 1.8 2.6 3.4 4.8 7.6 11 14 21 28 34 40 55 66 80 100 135 160 200 230 250 270 320 350 380 430 510 550 590 660 700 MCB Series G (Curve C) 2 4 6 10 10 16 20 25 32 50 FD 63 16 20 32 40 50 63 FD 160 Circuit Breaker Types and Ratings (A) MCCB Type FE FE FG FG FK 160 250 400 630 800 64 80 100 125 160 20 32 40 50 63 80 100 125 160 100 125 160 200 250 100 125 160 200 250 300 400 250 300 400 450 500 550 630 400 450 500 550 630 700 800 FK 1250 400 450 500 550 630 700 800 900 1050 1200 1250 FK 1600 640 700 800 900 1050 1200 1250 1400 1500 Notes: 1. FLC values are nominal for standard squirrel-cage induction motors of rated speed 1500 rpm (4 poles). Possible deviation of FLC values ± 10% depending on type and manufacturer. 2. Circuit breaker ratings are based on carrying 100% FLC continuous and 600% FLC for 10 seconds. Operating cycle 2 starts in rapid succession and up to 8 starts per hour. TECHNICAL 3. Suitable adjustments to the indicated ratings may be necessary for: a) Starting conditions in excess of the above conditions. b) High enclosure (fluid environment) temperatures. IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 491 MOTOR PROTECTION FUSE SELECTION FOR ASSISTED MOTOR STARTING (Star-Delta, Autotransformer, Resistor or Reactor) Motor FLC (A) From 0 1.5 2.2 3.2 5.6 10.1 14.1 18.1 22.1 28.1 32.1 40.1 51.1 80.1 100.1 125.1 160.1 200.1 250.1 315.1 355.1 400.1 450.1 500.1 560.1 630.1 670.1 710.1 To 1.4 2.1 3.1 5.5 10 14 18 22 28 32 40 51 80 100 125 160 200 250 315 355 400 450 500 560 630 670 710 750 Recommended GEC, GE or IPD Fuse-Link Rating (A) Type T ‘gG’ Type T ‘gM’ DIN Type ‘gL’ - ‘gG’ 2 4 4 4 6 6 10 10 16 16 20 20 25 20M25 25 32 32 35 32M35 35 40 32M40 40 50 50 63 63 80 80 100 100 125 125 160 160 200 200 250 250 315 315 355 355 400 400 450 500 500 500 560 630 630 630 670 800 710 800 750 800 Notes: 1. Assumed starting conditions: Motor Rating Run-Up Up to 1kW 2.5 x FLC for 20 secs. 1.1 to 7.5kW 3.5 x FLC for 20 secs. Greater than 75kW 3.5 x FLC for 15 secs. Operating cycle of 2 starts in rapid succession and up to 8 starts per hour. 2. Suitable adjustments to the recommended ratings may be necessary for: (a) Starting conditions in excess of the assumed starting conditions. (b) High enclosure (fluid environment) temperatures more than 35°C. Some fuses need to be derated as indicated on page 522. IPD INDUSTRIAL PRODUCTS 492 Product Catalogue 2013 Phone: 1300 556 601 www.ipdgroup.com.au MOTOR PROTECTION GE CIRCUIT BREAKER GUIDE FOR ASSISTED MOTOR STARTING (STAR-DELTA, 415V APPLICATIONS) Motor Rating kW 0.37 0.55 0.75 1.1 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 150 160 185 200 220 250 300 315 335 375 400 FLC (A) 1.1 1.5 1.8 2.6 3.4 4.8 7.6 11 14 21 28 34 40 55 66 80 100 135 160 200 230 250 270 320 350 380 430 510 550 590 660 700 MCB Series G (Curve C) 2 4 4 6 6 10 16 20 25 40 50 FD 63 16 20 32 40 50 63 Circuit Breaker Types and Ratings (A) MCCB Type FD FE FE FG FG 160 160 250 400 630 64 80 90 100 125 160 20 32 40 50 63 80 90 100 125 160 100 125 160 200 250 100 125 160 200 250 280 300 320 380 400 250 280 300 320 380 400 450 550 630 FK 800 320 380 400 450 550 650 700 750 800 FK 1250 400 450 550 650 700 750 850 950 Notes: 1. FLC values are nominal for standard squirrel-cage induction motors of rated speed 1500 rpm (4 poles). Possible deviation of FLC values ± 10% depending on type and manufacturer. 2. Circuit breaker ratings are based on carrying 100% FLC continuous and 600% FLC for 10 seconds. Operating cycle 2 starts in rapid succession and up to 8 starts per hour. TECHNICAL 3. Suitable adjustments to the indicated ratings may be necessary for: a) Starting conditions in excess of the above conditions. b) High enclosure (fluid environment) temperatures. IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 493 MOTOR PROTECTION GE CONTACTOR GUIDE FOR STAR-DELTA MOTOR STARTING 415V APPLICATIONS Motor Rating kW FLC (A) 0.37 1.1 0.55 1.5 0.75 1.8 1.1 2.6 1.5 3.4 2.2 4.8 3.7 7.6 5.5 11 5.5 11 7.5 14 7.5 14 11 21 15 28 18.5 34 18.5 34 22 40 22 40 30 55 30 55 37 66 37 66 45 80 55 100 75 135 90 160 110 200 132 230 150 250 160 270 185 320 200 350 220 380 250 430 300 510 315 550 335 590 375 660 400 700 Contactor Types Line and Delta Star MCO MCO MCO MCO MCO MCO MCO MCO MCO MCO MCO MCO MCO MCO MC1 MCO CL00 CL00 MC1 MCO CL00 CL00 CL02 CL00 CL02 CL01 CL25 CL01 CL03 CL01 CL25 CL02 CL03 CL02 CL04 CL25 CL04 CL03 CL45 CL25 CL45 CL03 CL06 CL04 CL07 CL45 CL08 CL06 CL09 CL07 CK75C CL08 CK75C CL08 CK75C CL09 CK08C CL09 CK08C CK75C CK85B CK75C CK09B CK75C CK09B CK75C CK95B CK08C CK10C CK08C CK10C CK85B CK10C CK09B CK10C CK09B TOL Relay Types MT03D MT03E MT03F MT03G MT03H MT03J MT03K MT03M RT1L MT03N RT1M RT1P RT1S RT1T RT1T RT1U RT1U RT1V RT1V RT1W RT1W RT2G RT2H RT2J RT2L RT3D RT3E RT3F RT3F RT3F RT4P RT4P RT4P RT4R RT5C RT5C RT5D RT5D Notes: 1. FLC values are nominal for standard squirrel-cage indication motors of rated speed 1500 rpm (4 poles). Possible deviation of FLC values ± 10% depending on type and manufacture. 2. Contactor types based on the following conditions: a) Starting duration not more than 20 seconds. b) Starting frequency of 2 starts in rapid succession and up to 8 starts per hour. 3. TOL relays selected for direct connection to the line contactor, in the delta branch of the motor starter circuit. 4. Suitable adjustments to the indicated types may be necessary for: a) Starting conditions in excess of the above conditions. b) High enclosure (fluid environment) temperatures. IPD INDUSTRIAL PRODUCTS 494 Product Catalogue 2013 Phone: 1300 556 601 www.ipdgroup.com.au MOTOR PROTECTION GE CONTACTOR GUIDE FOR AUTOTRANSFORMER MOTOR STARTING 415V APPLICATIONS Motor Rating kW FLC (A) 0.37 1.1 0.55 1.5 0.75 1.8 1.1 2.6 1.5 3.4 2.2 4.8 3.7 7.6 3.7 7.6 5.5 11 5.5 11 7.5 14 11 21 15 28 18.5 34 22 40 30 55 30 55 37 66 45 80 55 100 75 135 90 160 110 200 132 230 150 250 160 270 185 320 200 350 220 380 250 430 300 510 315 550 335 590 375 660 400 700 Line MCO MCO MCO MCO MCO MCO MC1 CL00 MC2 CL01 CL02 CL25 CL04 CL45 CL45 CL07 CL07 CL08 CL08 CL10 CK75C CK08C CK85B CK09B CK09B CK95B CK10C CK10C CK10C CK11C CK11C CK11C CK12B CK12B CK12B Contactor Types Transformer MCO MCO MCO MCO MCO MCO MCO CL00 MC1 CL00 CL00 CL01 CL02 CL25 CL04 CL45 CL45 CL06 CL07 CL07 CL09 CL10 CK75C CK75C CK08C CK08C CK85B CK09B CK09B CK95B CK10C CK10C CK10C CK11C CK11C Star MCO MCO MCO MCO MCO MCO MC0 CL00 MC0 CL00 CL00 CL01 CL02 CL02 CL25 CL25 CL03 CL04 CL45 CL06 CL07 CL08 CL09 CL10 CK75C CK75C CK75C CK08C CK08C CK85B CK09B CK09B CK95B CK95B CK10C TOL Relay Types MT03F MT03G MT03H MT03J MT03K MT03L MT03M RT1N MT03P RT1N RT1P RT1T RT1V RT1W RT1W RT2G RT2G RT2J RT2J RT2M RT3E RT3F RT4P RT4P RT4P RT4P RT5C RT5C RT5C RT5D RT5E RT5E RT5E RT5E RT5E Notes: 1. FLC values are nominal for standard squirrel-cage indication motors of rated speed 1500 rpm (4 poles). Possible deviation of FLC values ± 10% depending on type and manufacture. 2. Contactor types based on the following conditions: a) Starting duration not more than 20 seconds. b) Starting frequency of 2 starts in rapid succession and up to 8 starts per hour. c) Auto-transformer tap at 80%. TECHNICAL 3. Suitable adjustments to the indicated types may be necessary for: a) Starting conditions different to the above conditions. b) High enclosure (fluid environment) temperatures. IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 495 MOTOR PROTECTION FUSE SELECTION FOR FIRE PUMP MOTOR STARTING Motor FLC (A) kW 0.37 0.55 0.75 1.1 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 150 160 185 200 220 250 300 FLC (A) 1.1 1.5 1.8 2.6 3.4 4.8 7.6 11 14 21 28 34 40 55 66 80 100 135 160 200 230 250 270 320 350 380 430 510 Recommended GEC, GE or IPD Fuse-Link Rating (A) Type T ‘gG’ Type T ‘gM’ DINType ‘gL’ - ‘gG’ 4 4 6 4 6 6 10 6 16 10 16 16 20 20 32 20M32 25 35 20M35 32 50 32M50 40 63 32M63 50 80 63M80 63 80 63M80 80 100 63M100 100 125 100M125 125 160 100M160 160 160 160 200M250 200 250 250 200M250 250 315 315 355 315M355 315 355 315M355 355 400 400 450 400M450 500 450 400M450 500 500 630 560 630 630 800 Notes: 1. FLC values are nominal for standard squirrel-cage induction motors of rated speed 1500 rpm (4 pole). Possible deviation of FLC values ±10% depending on type and manufacturer. 2. Recommend fuse ratings are based on carrying 125% FLC continuously and operating in not less than 20 seconds at 600% FLC, in accordance with Clause 7.2.9.2 of AS/NZS 3000:2007. 3. Suitable adjustments to the recommended ratings may be necessary for high enclosure (fluid environment) temperatures, refer to de-rating information indicated on page 522. IPD INDUSTRIAL PRODUCTS 496 Product Catalogue 2013 Phone: 1300 556 601 www.ipdgroup.com.au MOTOR PROTECTION GE CIRCUIT BREAKER GUIDE FOR FIRE PUMP MOTOR STARTING 415V APPLICATIONS Motor Rating kW 0.37 0.55 0.75 1.1 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 150 160 185 200 220 250 300 315 335 375 400 FLC (A) 1.1 1.5 1.8 2.6 3.4 4.8 7.6 11 14 21 28 34 40 55 66 80 100 135 160 200 230 250 270 320 350 380 430 510 550 590 660 700 MCB Series G (Curve C) 4 6 6 10 16 16 25 40 50 63 FD 63 FD 160 Circuit Breaker Types and Ratings (A) MCCB Type FE FE FG FG FK 160 250 400 630 800 64 80 100 125 140 20 32 40 50 63 80 100 125 140 16 20 32 40 50 100 125 140 180 220 100 125 140 180 220 300 400 220 300 400 450 500 550 580 320 400 450 500 550 580 700 750 800 FK 1250 400 450 500 550 580 700 750 800 1000 1250 FK 1600 700 750 800 1000 1250 1300 1400 1500 1600 Notes: 1. FLC values are nominal for standard squirrel-cage induction motors of rated speed 1500 rpm (4 poles). Possible deviation of FLC values ± 10% depending on type and manufacturer. 2. Circuit breaker ratings are based on carrying 125% FLC continuously and opening in not less than 20 seconds at 600% FLC, in accordance with clause 7.2.9.2 of AS/NZS 3000:2007. TECHNICAL 3. Suitable adjustments to the indicated ratings may be necessary for high enclosure (fluid environment) temperatures. IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 497 MOTOR PROTECTION TYPE 2 COORDINATION CLASS 10 PROTECTION @ 415V AC For type 2 Coordination @ other voltage, please refer to product catalogues of your local representative. Upstream Record Plus Breakers selection N H L Type IIcc values in kA Ue= 400/415V AC 50kA 80kA 130kA FD63/160 FE160/250 50kA 80kA 130kA FG 400/630 50kA 80kA 130kA FK 800/1250 50kA 80kA 100kA SELECTION OF ASSOCIATED COMPONENTS (1) Motor P(kW) 0.75 1.1 1.5 2.2 3 4 5.5 7.5 10 11 15 18.5 22 25 30 37 45 55 75 90 110 132 160 200 220 250 300 315 335 In 2 2.6 3.6 5 7 8.3 11.5 16.1 21 22 30 37 43 49 58 72 86 104 144 179 207 247 300 360 400 462 560 582 619 Breaker details Type Ie FD63 /FE160 3 (2) FD63 /FE160 3 (2) FD63 /FE160 7 FD63 /FE160 7 FD63 /FE160 7 FD63/FE160 12.5 FD63/FE160 12.5 FD63/FE160 20 FD63 /FE160 30 FD63 /FE160 30 FD63 /FE160 30 FD63/FE160 50 FD63/FE160 50 FD63/FE160 50 FD/FE160 80 FD/FE160 80 FD/FE160 100 FE160 125 FE160 160 FE250 250 FE250 250 FE250 250 FG400 350 FG630 500 FG630 500 FG630 500 FK800 800 FK800 800 FK800 800 Im 35 35 70 80 86 125 150 200 300 300 390 478 561 635 800 934 1121 1346 1869 2500 2691 3214 3900 4680 5200 6004 6720 6985 6810 Contactor Type + O.R. CL25+RT1J CL25+RT1K CL03+RT1K CL03+RT12L CL03+RT1M CL06+RT2AN CL06+RT2AN CL06+RT2B CL06-RT2C CL06-RT2C CL06-RT2D CL06+RT2E CL06+RT2G CL06+RT2G CL09+RT2H CL09+RT2J CK75C+RT2L CK85B+RT3E CK85B+RT3F CK95B+RT4N CK10B+RT4P CK10B+RT4R CK10B+RT5C CK12B+RT5C CK12B+RT5D CK12B+RT5D CK13B+RT5E CK13B+RT5C CK13B+RT5C Notes: (1) The contactor has a breaking capacity that is sufficient to operate the specified motor up to the specified magnetic setting of the breaker. (2) The 3 AMP device is designed to operate AA current level up to 3.5 Amps. IPD INDUSTRIAL PRODUCTS 498 Product Catalogue 2013 Phone: 1300 556 601 www.ipdgroup.com.au MOTOR PROTECTION TYPE 2 COORDINATION CLASS 10 AND PROTECTION (WITH SMR2 OTHER CLASSES POSSIBLE) Upstream Record Plus Breakers selection N H L Type IIcc values in kA Ue= 400/415V AC 50kA 80kA 130kA FE160/250 FG400/630 50kA 80kA 130kA SELECTION OF ASSOCIATED COMPONENTS (1) Motor P(kW) 5.5 7.5 10 11 15 18.5 22 25 30 37 45 55 75 90 110 132 160 200 220 250 In 11.5 16.1 21 22 30 37 43 49 58 72 86 104 144 179 207 247 300 360 400 462 Type FE160 FE160 FE160 FE160 FE160 FE160 FE160 FE160 FE160 FE160 FE160 FE160 FE160 FE250 FE250 FE250 FG400 FG630 FG630 FG630 Breaker details Ie 25 25 25 25 63 63 63 63 63 125 125 125 160 250 250 250 350 500 500 500 Im 150 200 300 300 390 478 561 635 800 934 1121 1346 1869 2500 2691 2967 3900 4680 5200 6004 Contactor Type + O.R. CL08 CL08 CL08 CL08 CL09 CL09 CL09 CL09 CL09 CK85B CK85B CK85B CK85B CK95B CK95B CK95B CK10C CK12B CK12B CK12B TECHNICAL Notes: (1) The contactor has a breaking capacity that is sufficient to operate the specified motor up to the specified magnetic setting of the breaker. (2) The 3 AMP device is designed to operate AA current level up to 3.5 Amps. IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 499 MOTOR PROTECTION TYPE 2 COORDINATION CLASS 20(3) PROTECTION Upstream Record Plus Breakers selection N H L Type IIcc values in kA Ue= 400/415V AC 50kA 80kA 130kA FD63/160 FE160/250 50kA 80kA 130kA FG 400/630 50kA 80kA 130kA FK 800/1250 50kA 80kA 100kA SELECTION OF ASSOCIATED COMPONENTS (1) Motor P(kW) In 0.75 2 1.1 2.6 1.5 3.6 2.2 5 3 6.6 4 8.3 5.5 11.5 7.5 16.1 10 21 11 22 15 30 18.5 37 22 43 49 25 30 58 37 72 45 86 55 104 75 144 90 179 110 207 132 247 160 300 200 360 220 400 250 462 300 560 315 582 335 619 Breaker details Type Ie FD63/FE160 3 (2) FD63/FE160 3 (2) FD63/FE160 7 FD63/FE160 7 FD63/FE160 7 FD63/FE160 12.5 FD63/FE160 12.5 FD63/FE160 20 FD63/FE160 30 FD63/FE160 30 FD63/FE160 30 FD63/FE160 50 FD63/FE160 50 FD63/FE160 50 FD/FE160 80 FD/FE160 80 FD/FE160 100 FE160 125 FE160 160 FE250 250 FE250 250 FE250 250 FG400 350 FG630 500 FG630 500 FG630 500 FK800 800 FK800 800 FK800 800 Im 35 35 70 80 86 125 150 200 300 300 390 478 561 635 800 934 1121 1346 1869 2500 2691 3214 3900 4680 5200 6004 6720 6985 6810 Contactor Type + O.R. CL25+RT12J CL25+RT12K CL03+RT12K CL03+RT12L CL03+RT12M CL06+RT2AN CL06+RT2AN CL06+RT2B CL06-RT2C CL06-RT2C CL06-RT22D CL06+RT22E CL06+RT22G CL06+RT22G CL09+RT22H CL09+RT22J CK75C+RT22L CK85B+RT32E CK85B+RT32F CK95B+RT32F CK10B+RT5LB CK10B+RT5LB CK10B+RT5LB CK12B+RT52LC CK12B+RT52LD CK12B+RT52LD CK13B+RT5LE CK13B+RT5LE CK13B+RT5LE Notes: (1) The contactor has a breaking capacity that is sufficient to operate the specified motor up to the specified magnetic setting of the breaker. (2) The 3 AMP device is designed to operate AA current level up to 3.5 Amps. IPD INDUSTRIAL PRODUCTS 500 Product Catalogue 2013 Phone: 1300 556 601 www.ipdgroup.com.au MOTOR PROTECTION TYPE 2 COORDINATION START DELTA STARTERS Upstream Record Plus Breakers selection N H L Type IIcc values in kA Ue= 400/415V AC 50kA 80kA 130kA FD63/160 FE160/250 50kA 80kA 130kA FG400/630 50kA 80kA 130kA FK800/1250 50kA 80kA 130kA Breaker details Type Ie FD63/FE160 7 FD63/FE160 7 FD63/FE160 12.5 FD63/FE160 12.5 FD63/FE160 20 FD63/FE160 30 FD63/FE160 30 FD63/FE160 30 FD63/FE160 50 FD63/FE160 50 FD63/FE160 50 FD/FE160 80 FD/FE160 80 FD160 100 FE160 100 FE160 125 FE160 160 FE250 250 FE250 250 FE250 250 FG400 350 FG630 500 FG630 500 FG630 500 FK800 800 FK800 800 FK800 800 Im 80 86 125 150 200 300 300 390 478 561 635 800 934 1121 1121 1346 1869 2500 2691 3214 3900 4680 5200 6004 6720 6985 6810 Contactor Type + O.R. CL03+RT12L CL03+RT1M CL06+RT2AN CL06+RT2AN CL06+RT2B CL06-RT2C CL06-RT2C CL06-RT2D CL06+RT2E CL06+RT2G CL06+RT2G CL09+RT2H CL09+RT2J CL09+RT2L CK75C+RT2L CK85B+RT3E CK85B+RT3F CK95B+RT4N CK10B+RT4P CK10B+RT4R CK10B+RT5C CK12B+RT5C CK12B+RT5D CK12B+RT5D CK13B+RT5E CK13B+RT5C CK13B+RT5C Delta Cont. CL03 CL03 CL04 CL04 CL45 CL45 CL45 CL45 CL06 CL06 CL06 CL09 CL09 CL09 CL10 CK75C CK08C CK85B CK95B CK95B CK95B CK10C CK10C CK10C CK12C CK12C CK12C Star Cont. CL03 CL03 CL04 CL04 CL45 CL45 CL45 CL45 CL06 CL06 CL06 CL09 CL09 CL09 CL10 CL10 CL10 CK75C CK75C CK75C CK85B CK10C CK10C CK10C CK12C CK12C CK12C TECHNICAL Motor P(kW) In 2.2 5.0 3 6.6 4 8.3 5.5 11.5 7.5 16.1 10 21 11 22 15 30 18.5 37 22 43 25 49 30 58 37 72 45 86 45 86 55 104 75 144 90 179 110 207 132 247 160 300 200 360 220 400 250 462 300 560 315 582 335 619 IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 501 TRANSFORMER RATINGS GUIDE TO LOW VOLTAGE FAULT LEVEL kVA 15 25 50 100 150 200 300 315 400 500 600 750 750 800 1000 1200 1350 1500 2000 2500 mVA kVA/1000 0.015 0.025 0.050 0.100 0.150 0.200 0.300 0.315 0.400 0.500 0.600 0.750 0.750 0.800 1.000 1.200 1.350 1.500 2.000 2.500 Current (I) @ 11kV 0.79 1.31 2.62 5.25 7.87 10.5 15.75 16.53 20.99 26.24 26.24 39.36 39.36 41.99 52.49 62.98 70.86 78.73 104.97 131.22 Current (I) @ 433V 20 33.33 66.67 133.34 200.01 266.67 400.01 420.01 533.35 666.69 666.69 1000.03 1000.03 1066.70 1333.37 1600.05 1800.05 2000.06 2666.74 3333.43 Typical %Z 4.75 4.5 4.5 4.75 4.75 4.75 4.75 5 4.75 4.75 4.75 4.75 6.25 4.75 4.75 5 5.25 5.5 5.5 6 Z1 @ 433V in Ohms 0.5937 0.3375 0.1687 0.0891 0.0594 0.0445 0.0297 0.0298 0.0223 0.0178 0.0148 0.0119 0.0156 0.0111 0.0089 0.0078 0.0073 0.0069 0.0052 0.0045 PSC @ 433V in kA 0.421 0.741 1.482 2.807 4.211 5.614 8.421 8.400 11.228 14.035 16.843 21.053 16.000 22.457 28.071 32.001 34.287 36.365 48.486 55.557 Note: The attached calculations are based on zero source impendance and are intended as a guide only. Example: Fault level for 400kA Sub: Ohms = KV Line Voltage2 x %Z MVA KA = KV Line Voltage IPD INDUSTRIAL PRODUCTS 502 Product Catalogue 2013 = (433)2 0.4x106 100 = 433 = 11.228 KA Phone: 1300 556 601 www.ipdgroup.com.au TRANSFORMER PROTECTION FUSE SELECTION FOR 3-PHASE TRANSFORMER PRIMARIES AT 415VAC Transformer Rating kVA 0.5 1 2 3 4 5 6 7 8 10 12 15 20 25 30 40 50 75 100 125 150 200 250 300 400 500 630 750 Primary FLC (A) 0.8 1.5 3.1 4.6 6.1 7.7 9.2 10.7 12.2 15 18 23 31 38 46 61 77 115 153 191 230 306 383 459 612 765 964 1148 Recommended GEC, English Electric GE or IPD Fuse-Link Rating (A) Type T ‘gG’ DIN Type ‘gL’-’gG’ 4 4 6 4 10 6 16 10 16 10 16 16 20 16 20 16 20 16 25 20 32 25 35 32 40 40 50 50 63 63 80 80 80 80 125 125 160 160 200 200 250 250 315 315 400 400 500 500 630 630 800 800 1250 1000 1250 - TECHNICAL Notes: 1. FLC values are typical only. Possible deviation of FLC values ±5% depending on manufacturer. 2. Recommended fuse ratings allow for transformer magnetising inrush current of 12 times FLC for 0.1 seconds. 3. Suitable adjustments to the recommended ratings may be necessary for high enclosure (fluid environment) temperatures, refer to de-rating information indicated on page 522. IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 503 TRANSFORMERS & CAPACITOR PROTECTION Transformer value < 50 kvA >= 50 kvA 1ph kVA 2.5 4 5 6.3 8 10 12.5 16 20 25 31.5 40 50 63 80 100 125 160 Maximum crest inrush values 1st Period 2nd Period 5 ms. 25 ms. 25 x In 12 x In 15 x In 8 x In Transformer ratings 240V 3ph 400/415V In kVA In 10 6.3 9 11 8 12 17 10 14 12.5 18 27 16 23 34 20 28 42 25 35 53 31.5 44 40 56 68 50 70 84 63 89 105 80 113 133 100 141 169 125 176 211 160 225 266 200 287 338 250 352 422 315 444 528 400 563 675 500 704 630 887 800 1126 1000 1408 3rd Period 45 ms. 5 x In 3.5 x In Type FD160N, FD160H or L FD160N, FD160H or L FD160N, FD160H or L FD160N, FD160H or L FD160N, FD160H or L FD160N, FD160H or L FD160N, FD160H or L FD160N, FD160H or L FD160N, FD160H or L FD160N, FD160H or L FD160N, FD160H or L FE160N, H or L FE160N, H or L FE160N, H or L FE250N, H or L FE250N, H or L FG400N, H or L FG400N, H or L FG630N, H or L FG630N, H or L FK800N or H FK1250N or H FK1250N or H FK1600N or H Record Plus breaker Trip unit type & rating* LTMD-25 LTMD-25 LTMD-32 LTMD-32 LTMD-40 LTMD-50 LTMD-63 LTMD-80 LTMD-100 LTMD-125 LTMD-125 SMR1-125 SMR1-125 SMR1-160 SMR1-250 SMR1-250 SMR1-350 SMR1-350 SMR1-500 SMR1-630 SMR1-800 SMR1-1000 SMR1-1250 SMR1-1600 Ist 250 250 320 320 400 500 630 800 1000 1250 1250 PROTECTION OF CAPACITOR BANKS Un = 400/415V (phase to phase voltage) Capacitor rating Record Plus (kVAr) breaker 10 FD160N, FD160H or L 15 FD160N, FD160H or L 20 FD160N, FD160H or L 25 FD160N, FD160H or L 30 FD160N, FD160H or L 35 FD160N, FD160H or L 40 FD160N, FD160H or L 45 FD160N, FD160H or L 50 FD160N, FD160H or L 60 FD160N, FD160H or L 70 FD160N or FE160N, H or L 80 FE250N, H or L 90 FE250N, H or L 100 FE250N, H or L 120 FE250N, H or L 140 FG400N, H or L 160 FG400N, H or L 180 FG400N, H or L 200 FG630N, H or L 250 FG630N, H or L 300 FG630N, H or L 350 FK800N, H or H IPD INDUSTRIAL PRODUCTS 504 Product Catalogue 2013 Phone: 1300 556 601 Ir setting (min) 21 A 31 A 41 A 52 A 62 A 72 A 83 A 93 A 103 A 124 A 144 A 165 A 186 A 206 A 248 A 289 A 330 A 372 A 413 A 516 A 619 A 722 A www.ipdgroup.com.au CAPACITOR PROTECTION FUSE SELECTION FOR 3-PHASE CAPACITOR BANKS AT 415VAC Capacitor Bank Rating kVAr 5 7.5 10 15 20 25 30 35 40 50 60 75 90 100 110 120 135 150 160 180 190 200 225 240 275 300 360 400 FLC (A) 6.9 10.4 13.9 20.9 27.8 34.8 41.7 48.7 55.6 69.6 83.5 104 125 139 153 167 188 209 223 250 264 278 313 334 383 417 501 557 Recommended GEC, GE or IPD Fuse-Link Rating (A) Type T ‘gG’ DIN Type ‘gL’-’gG’ 16 16 16 16 25 25 32 32 50 50 63 63 63 63 80 80 100 100 125 125 125 125 160 160 200 200 250 250 250 250 250 250 315 315 315 315 355 355 400 400 400 400 450 500 500 500 500 500 630 630 630 630 750 800 1000 1000 Notes: 1. Recommended fuse ratings allow for a capacitor manufacturing tolerance of +10% on the kVAr values and the possibility of up to 30% constant overload of a capacitor bank due to harmonic currents. TECHNICAL 2. Suitable adjustments to the recommended ratings may be necessary for high enclosure (fluid environment) temperatures, refer to de-rating information indicated on page 522. IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 505 BACKUP PROTECTION MCCB AND SWITCH DISCONECTOR BACKUP PROTECTION Record Plus™ circuit breakers excel in their characteristics as current and energy limiting devices. This allows one to use lighter and more economical downstream busbar systems and switchgear. A frequently used combination is that of a Record Plus™ breaker, used as a protection and switching device in the mains switchboard, and a Dilos load break switch, as an incomer, in a downstream, secondary switchboard. In this application the Dilos needs to be able to withstand the current and energy values on a short-circuit event, this taking the limiting effects of the upstream breaker into account. The table indicates the maximum prospective short-circuit that the combination of an upstream Record Plus™ and a downstream Dilos or Record Plus™ in its switch disconnect variant (type Y) can withstand. Protection of Switch Disconectors (Dilos or Record PlusTM) Valid for 400/415V AC Upstream Record Plus™ circuit breaker FD160S FD160S FD160N FD160N FD160H FD160N FD160L FD160L FE160N FE160N FE160H FE160H FE160L FE160L FE250N FE250H FE250L FG400N FG400H FG400L FG630N FG630H FG630L FK800N FK800H FK1250N FK1250H FK1600N FK1600H Breaking capacity, Icu = Ics (kA eff.) 30 30 50 50 80 80 150 150 50 50 80 80 150 150 50 80 150 50 80 150 50 80 150 50 80 50 80 50 80 Downstream Dilos switch 1 & 1H 2 1 & 1H 2 1 & 1H 2 1 & 1H 2 1 & 1H 2 1 & 1H 2 1 & 1H 2 3 3 3 4 4 4 4 4 4 6 6 6 6 7 7 Maximum allowable short-circuit (kA eff.) 18 18 25 25 30 30 36 36 25 25 30 30 36 36 50 80 150 50 80 150 50 80 150 50 80 50 80 50 80 Downstream Record Plus™ switch FD63Y FD160Y FD63Y FD160Y FD63Y FD160Y FD63Y FD160Y FE63Y FE160Y FE63Y FE160Y FE63Y FE160Y FE250Y FE250Y FE250Y FG400Y FG400Y FG400Y FG630Y FG630Y FG630Y FK800Y FK800Y FK1250Y FK1250Y FK1600Y FK1600Y Maximum allowable short-circuit (kA eff.) 30 30 50 50 80 80 150 150 50 50 80 80 150 150 50 80 150 50 80 150 50 80 150 50 80 50 80 50 80 FAULT-CURRENT LIMITER FUSES SELECTION FOR MINIATURE CIRCUIT BREAKERS AT 415VAC 50kA PROSPECTIVE Miniature Minimum Maximum Fuse Rating (A) Circuit Fuse For For Breaker Rating GE Series Ge Series Rating (A) (A) G60 G100 4 20 200 250 6 25 200 250 10 40 200 250 16 50 200 250 20 63 200 250 25 80 200 250 32 100 200 250 40 125 200 250 50 160 200 250 63 160 200 250 Note: Fuses are type ‘T’, ‘gG’ or DIN type ‘gL’ - ‘gG’ IPD INDUSTRIAL PRODUCTS 506 Product Catalogue 2013 Phone: 1300 556 601 www.ipdgroup.com.au BACKUP PROTECTION Record Plus Moulded Case Circuit Breakers (at 400/415V AC; table B2 ed. 2c) Icu in kA FE250V 36 FE250N 50 FE250H 80 FE250L 150 FG400N 50 Icu of the combination in kA 10 15 25 20 15 22 25 --25 25 30 36 30 30 30 36 42 36 36 36 42 50 42 42 42 50 65 50 50 30 36 42 36 36 36 42 50 42 42 42 50 65 50 50 22 25 --25 30 30 36 36 30 36 36 42 42 36 36 36 42 42 36 16 22 ---- 100 50 25 100 50 100 25 100 50 ---------- ---------- --42 ---42 --- -80 50 -80 -50 -80 150 150 65 150 150 150 65 150 150 --42 ---42 --- -80 50 -80 -50 -80 150 150 65 150 150 150 65 150 150 ---------- --42 ---42 --- -80 50 -80 -50 -80 150 150 65 150 150 150 65 150 150 ---------- 18 25 36 50 80 50 80 50 80 50 80 50 80 50 80 50 80 22 ----------------- 25 30 ---------------- 30 36 42 --------------- 36 42 50 80 -------------- 42 50 65 150 150 ------------- 30 36 42 --------------- 36 42 50 80 -80 ------------ 42 50 65 150 150 150 150 ----------- 22 ----------------- 30 36 42 --------------- 36 42 50 80 -80 -80 ---------- 42 50 65 150 150 150 150 150 150 --------- 30 36 42 --------------- FG400H 80 FG400L 150 FG630N 50 FG630H 80 FG630L 150 Icu in kA Downstream Redline G60 & GT10 G100 GT25 <=25A GT25; 32 & 40A GT25; 50 & 63A Surion GPS1B/MS <=10A GPS1B/MS 12.5A GPS1B/MS >=16A GPS1B/MH <=12.5A GPS1B/MH >12.5A GPS2B/MS 10A GPS2B/MS >10A GPS2B/MH 10A GPS2B/MH >10A TM Record Plus FD63/160C FD63/160E FD63/160S FD63/160N FD63/160H FE160N FE160H FE250N FE250H FG400N FG400H FG630N FG630H FK800N FK800H FK1250N FK1250H Upstream Record PlusTM type FD63/160L FE160N FE160H FE160L 150 50 80 150 Upstream Record PlusTM type FK800N FK800H FK800L FK1250N FK1250H FK1250L FK1600N FK1600H 50 80 100 50 80 100 50 80 Icu of the combination in kA 10 15 25 20 15 16 22 ---- 16 22 ---- 12 16 ---- 12 16 ---- 12 16 ---- ------ ------ ------ ------ ------ ------ ------ ------ 100 50 25 100 50 100 25 100 50 ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- ---------- 18 25 36 50 80 50 80 50 80 50 80 50 80 50 80 50 80 36 42 50 80 -80 -80 -80 -------- 42 50 65 150 150 150 150 150 150 150 150 ------- 30 36 42 --------------- 36 42 50 80 -80 -80 -80 -80 ------ 42 50 65 150 150 150 150 150 150 150 150 150 150 ----- ------------------ ---80 -80 -80 -80 -80 -80 -80 -- ---100 100 100 100 100 100 100 100 100 100 100 100 100 100 ------------------ ---80 -80 -80 -80 -80 -80 -80 -- ---100 100 100 100 100 100 100 100 100 100 100 100 100 100 ------------------ ---80 -80 -80 -80 -80 -80 -80 -- IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 TECHNICAL Downstream Redline G60 & GT10 G100 GT25 <=25A GT25; 32 & 40A GT25; 50 & 63A Surion GPS1B/MS <=10A GPS1B/MS 12.5A GPS1B/MS >=16A GPS1B/MH <=12.5A GPS1B/MH >12.5A GPS2B/MS 10A GPS2B/MS >10A GPS2B/MH 10A GPS2B/MH >10A TM Record Plus FD63/160C FD63/160E FD63/160S FD63/160N FD63/160H FE160N FE160H FE250N FE250H FG400N FG400H FG630N FG630H FK800N FK800H FK1250N FK1250H FD63/160E FD63/160S FD63/160N FD63/160H 25 36 50 80 15 www.ipdgroup.com.au Product Catalogue 2013 507 NOTES IPD INDUSTRIAL PRODUCTS 508 Product Catalogue 2013 Phone: 1300 556 601 www.ipdgroup.com.au DISCRIMINATION & SELECTIVITY Supply Source Up-Stream Fuse Down-Stream Fuse Fault Point DISCRIMINATION BETWEEN FUSES AT 415VAC Type T ‘gG’ 2 4 6 10 16 20 25 32 32 35 40 50 63 63 80 100 125 160 200 250 315 355 400 400 450 500 560 630 670 710 750 800 Down-Stream Fuse Rating (A) Type T ‘gM’ DIN Type ‘gL’-’gG’ 4 6 10 16 20 20M25 25 20M32 32 32M35 35 32M40 40 32M50 50 32M63 63 63M80 80 63M100 100 100M125 125 100M160 160 100M200 200 200M250 250 200M315 315 315M355 400 400M450 500 630 630M670 800 Minimum Up-Stream Fuse Rating (A) Type T ‘gG’ DIN Type ‘gL’-’gG’ 4 4 6 6 10 10 16 16 25 25 32 32 40 40 40 40 50 50 50 50 63 63 80 80 125 125 125 100 160 125 160 160 200 200 250 250 315 315 400 400 500 500 560 630 630 800 630 630 670 800 750 800 800 1000 1000 1000 1250 1250 1250 1250 - Notes: 1. Fuses must be GE or IPD brands of fuse-links only. Not applicable for other manufacturers’ fuses. 2. The selected fuse ratings achieve discrimination for overload conditions and short-circuit currents up to 80kA. 3. This discrimination ensures that the down-stream fuse operates and the up-stream fuse remains unaffected. IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 TECHNICAL 4. Where the up-stream fuse supplies more than one down-stream fuse, the minimum up-stream fuse rating should be increased to allow for load biasing effects. 15 www.ipdgroup.com.au Product Catalogue 2013 509 DISCRIMINATION & SELECTIVITY SELECTIVITY DISCRIMINATION TABLES Selectivity Discrimination tables: Where discrimination is partial the selectivity limits in kA Is are listed. Where ‘T’ is found in the tables, this indicates total discrimination up to the highest breaking capacity of the devices. These discrimination/selectivity limits are only valid if the ratio between the current settimes, ranks or time settings of upstream & downstream breakers are equal or higher than the factor indicated below. L TM L TM TM 1.6 20 TM LTM LTMD Mag. Break™ SMR1 & SMR1e SMR1s, g and SMR2 MPRO 17, 20, 30 & 40 Terminology Thermal Magnetic Trip Unit Ir = Overload setting Selective Thermal Magnetic Trip Unit Ir = Overload setting Magnetic Only Trip Unit Im = Magnetic setting Selective Electronic Trip Unit Ir = Setting on LT device Enhanced Electronic trip Unit Mpact Electronic Trip Unit Ir = Setting on LT device LTD class, time setting at 7.2 x Ir Im = Magnetic setting Im = Magnetic setting Ist = Setting on ST device Ist = Setting on ST device STD Delay setting on ST device A2S Cropped short time delay setting Inst. = Setting on I ( Instantaneous ) device IPD INDUSTRIAL PRODUCTS 510 Product Catalogue 2013 Phone: 1300 556 601 www.ipdgroup.com.au DISCRIMINATION & SELECTIVITY SELECTIVE TABLES (RECORD PLUS MOULDED CASE CIRCUIT BREAKERS; TABLE D1 ED. 2C) FDC & FDE 63/160 LTM Upstream FDS 63/160 LTMD In in A In Downstream 40 50 63 50 63 80 In in A 100 125/ 160 40 50 T 3.5kA T 63 80 100 125/160 6kA 6kA T T 8kA T T 3.5kA T T T T T T T T T - T 10kA T T T - T T T - T 1.6kA 3.5kA T T T T T T T T T 10kA T T T - T T T T T 1.6kA 3.5kA 0.8kA 1.2kA 6kA 6kA 1.2kA 3kA 6kA T 8kA 3kA 4kA 6kA - - 3.5kA T T T - - 3.5kA T T 6kA - - - 3.5kA T T - - - 3.5kA T T - - - - 8kA T - - - - 8kA T T 25 - 32 - - 40 - - - 50 - - - 63 - - - 1.2kA 1.5kA - 1.5kA 2kA 6kA 10kA T 10kA 10kA T T T T 10kA 10kA T T T 6kA 8kA T 3.5kA 10kA T T T T 3.5kA 10kA T T T T 0.8kA 1.2kA 6kA 6kA T 1.6kA 3.5kA T T T T 1.6kA 3.5kA T T T T T 25 - 32 - - 40 - - - 50 - - - 63 - - - 1.2kA 3kA 6kA 8kA - - 10kA 10kA T T - - 10kA 10kA T 3kA 4kA 6kA - - 3.5kA 10kA T T - - 3.5kA 10kA T 6kA - - T - - 16 0.6kA 2.5kA 6kA 20 0.6kA 2.5kA 3kA Record Plus 40 Selectivity limit in kA* 16 0.6kA 2.5kA 6kA 20 0.6kA 2.5kA 3kA HTI C curve 100 125/160 (A) 16 0.6kA 2.5kA 6kA 20 0.6kA 2.5kA 3kA Redline 80 FDN, H & L 63/160 LTMD In in A 1.2kA 1.5kA - 3.5kA 10kA - 1.5kA 2kA - - - - 8kA T - - - - 8kA 10kA T 10kA 10kA T T T T 10kA 10kA T T T T 6kA 8kA T 3.5kA 10kA T T T T 3.5kA 10kA T T T T 1.6kA 3.5kA 15kA T T 1.6kA 3.5kA 15kA T T - - 10kA 10kA 3.5kA 10kA 15kA 6kA T 6kA 8kA - - 10kA 10kA 3kA 4kA 6kA - - 3.5kA 10kA 15kA T - - 6kA - - - 3.5kA 10kA T - - - 2kA - - - 8kA T - - - - - 40 - - - 50 - - - 63 - - - T - 1.2kA 3kA - 32 T 6kA 0.8kA 1.2kA 6kA 25 T 3.5kA 10kA 1.2kA 1.5kA - 1.5kA T - T T T T T T 3.5kA 10kA T 8kA T - 80 - - - - - 1.9kA - - - - - 2.5kA - - - - - 2.5kA 100 - - - - - 1.9kA - - - - - 2.5kA - - - - - 2.5kA T T 3.5kA 15kA 15kA T T 10kA T T - 10kA T T 3.5kA 15kA 15kA T T T T T T - - 6kA T T T GPS1BS & GPS1MS 20 0.6kA 2.5kA 6kA 25 - 6kA 10kA T 1kA 1.2kA 6kA 6kA T GPS2BS & GPS2MS 32 - - 40 - - - 50 - - - - 1.2kA 3kA 6kA 10kA - - 6kA 3kA 4kA 6kA - - - 6kA T T - - - 6kA T 6kA - - - 3.5kA T T - - - 3.5kA T 63 - - - - T 1.6kA 2kA - - - - 8kA T - - - - 8kA T 20 T T T T 25 - T 32 - 1.2kA 1.6kA 2.5kA 15kA 15kA - 10kA 10kA 6kA 6kA T T T T T T T T T T T T T T T - 3.5kA T T T T - 3.5kA T T T T T T T - - T T T T 6kA 6kA 8kA T - - T 40 - - - 6kA 8kA T - - T T T T - - T T T T 50 - - - - 6kA T - - - 3.5kA T T - - - 3.5kA T T 63 - - - - - T - - - - - - 25 0.4kA 0.5kA 0.6kA 0.8kA 1kA 0.5kA 0.6kA 0.8kA 1kA 32 1.3kA 8kA T 0.6kA 0.8kA 0.9kA 1.2kA 1.5kA 3.5kA 0.8kA 0.9kA 1.2kA 1.5kA 3.5kA 8kA T 0.6kA 0.8kA 0.9kA 1.2kA 1.5kA 3.5kA 1.3kA - 40 - - - 0.8kA 1kA 1.3kA - - - 1.2kA 1.5kA 3.5kA - - - 1.2kA 1.5kA 3.5kA 50 - - - 0.8kA 1kA 1.3kA - - - 1.2kA 1.5kA 3.5kA - - - 1.2kA 1.5kA 3.5kA 63 - - - - 1kA 1.3kA - - - - 80 - - - - - 1.3kA - - - - 1.5kA 3.5kA - 3.5kA - 0.8kA 0.9kA 1.2kA 1.5kA 3.5kA - - - - - - - - 1.5kA 3.5kA - 3.5kA Remark; For MCB’s with D type Curve assume a C curve type with a one step higher rating. E.G. Selectivity FD160 80Amp LTM with downstream C Curve 40A MCB = 3kA, for D curve 40A, take the value mentioned for 50A C curve, here 1.2kA TECHNICAL *Where T is mentioned Selectivity is full up until the Icu of the downstream device IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 511 DISCRIMINATION & SELECTIVITY SELECTIVE TABLES (RECORD PLUS MOULDED CASE CIRCUIT BREAKERS; TABLE D2 ED. 2C) Upstream FE160N, H & L LTM FE160N, H & L LTMD FE160N, H & L SMR1 160A FE250V LTM 160A 200A FE250N, H & L LTMD 250A 125A 160A 200A FE250N, H & L SMR1 63A 80A 100A 125A 160A 100A 125A 160A 63A 125A 250A 125A 160A 250A 6kA 6kA 8kA T T T T T T T T T T T T T T T T T T 25A 1.2kA 6kA 6kA T T T T T T T T T T T T T T T T T T DME100 32A 1.2kA 3kA 6kA 8kA T T T T T T T T T T T T T T T T T B/C curve 40A -- 3kA 4kA 6kA 6kA T T T T T T T T T T T T T T T T 50A -- -- 1.5kA 6kA 6kA T T T -- T T T T T T T T T T T T Downstream Selectivity limit in kA* In (A) Redline <= 20A 63A Redline <= 20A -- -- 1.5kA 2kA 2kA T T T -- T T T T T T T T T T T T 6kA 6kA 8kA T T T T T T T T T T T T T T T T T T T G60 & DM100 25A 1.2kA 6kA 6kA T T T T T T T T T T T T T T T T T B/C curve 32A 1.2kA 3kA 6kA 8kA T T T T T T T T T T T T T T T T T 40A -- 3kA 4kA 6kA 6kA T T T T T T T T T T T T T T T T 50A -- 1.2kA 1.5kA 6kA 6kA T T T -- T T T T T T T T T T T T 63A -- -- 1.5kA 2kA 2kA T T T -- T T T T T T T T T T T T 6kA 6kA 8kA T T T T T T T T T T T T T T T T T T G100 & GT25 Redline 25A 1.2kA 6kA 6kA T T T T T T T T T T T T T T T T T T B/C curve 32A 1.2kA 3kA 6kA 8kA T T T T T T T T T T T T T T T T T 40A -- 3kA 4kA 6kA 6kA T T T T T T T T T T T T T T T T Redline HTI C curve Surion <= 20A 50A -- -- 1.5kA 6kA 6kA T T T -- T T T T T T T T T T T T 63A -- -- 1.5kA 2kA 2kA T T T -- T T T T T T T T T T T T 80A -- -- 1.5kA 2kA 2kA -- T T -- T T 1.9kA 2.5kA 3kA T T T T T T T 100A -- -- -- -- 2kA -- -- T -- -- T 1.9kA 2.5kA 3kA -- T T T -- T T 125A <= 20A -- -- -- -- -- -- -- -- -- -- -- -- -- 3kA -- T T T -- T T 6kA 6kA 10kA T T T T T T T T T T T T T T T T T T T GPS1BS & 25A 1.2kA 6kA 6kA T T T T T T T T T T T T T T T T T GPS1MS 32A 1.2kA 3kA 6kA 10kA 10kA T T T T T T 10kA T T T T T T T T T GPS2BS & 40A -- -- 4kA 6kA 6kA T T T T T T 6kA 10kA T T T T T T T T GPS2MS Surion 50A -- -- 1.6kA 6kA 6kA T T T -- T T 6kA 6kA 10kA T T T T T T T 63A -- -- -- 2kA 2kA -- T T -- T T 2kA 6kA 6kA T T T T T T T <= 20A T T T T T T T T T T T T T T T T T T T T T 25A 15kA 15kA T T T T T T T T T T T T T T T T T T T GPS1MH 32A 6kA 6kA 8kA T T T T T T T T T T T T T T T T T T GPS2BH & 40A -- 6kA 8kA T T T T T T T T T T T T T T T T T T GPS1BH & GPS2MH Record Plus FD63/160E LTM/MO/GTM 50A -- -- 6kA T T T T T -- T T T T T T T T T T T T 63A -- -- -- T T -- T T -- T T T T T T T T T T T T <= 40A -- 0.8kA 1kA 1.2kA 1.6kA T T T T T T 1.6kA 2kA 2.5kA T T T T T T T 50A -- -- 1kA 1.2kA 1.6kA T T T -- T T 1.6kA 2kA 2.5kA T T T T T T T 63A -- -- -- 1.2kA 1.6kA T T T -- T T 1.6kA 2kA 2.5kA T T T T T T T 80A -- -- -- 1.2kA 1.6kA -- T T -- -- T 1.6kA 2kA 2.5kA T T T T T T T 100A -- -- -- -- 1.6kA -- -- T -- -- T 1.6kA 2kA 2.5kA -- T T T -- T T 125A -- -- -- -- -- -- -- -- -- -- -- -- 2kA 2.5kA -- -- T T -- -- T 160A Record Plus <= 40A -- -- -- -- -- -- -- -- -- -- -- -- -- 2.5kA -- -- -- T -- -- T 0.6kA 0.8kA 1kA 1.2kA 1.6kA 30kA 30kA 30kA 36kA 36kA 36kA 1.6kA 2kA 2.5kA 42kA 42kA 42kA 42kA 50kA 50kA 50kA FD63/160S, N 50A -- 0.8kA 1kA 1.2kA 1.6kA 30kA 30kA 30kA -- 36kA 36kA 1.6kA 2kA 2.5kA 42kA 42kA 42kA 42kA 50kA 50kA 50kA H&L 63A -- -- 1kA 1.2kA 1.6kA 30kA 30kA 30kA -- 36kA 36kA 1.6kA 2kA 2.5kA 42kA 42kA 42kA 42kA 50kA 50kA 50kA LTMD Record Plus FE160 N, H & L LTM/MO/GTM 80A -- -- -- 1.2kA 1.6kA -- 30kA 30kA -- 36kA 36kA 1.6kA 2kA 2.5kA 42kA 42kA 42kA 42kA 50kA 50kA 50kA 100A -- -- -- -- 1.6kA -- -- 30kA -- -- 36kA 1.6kA 2kA 2.5kA -- 42kA 42kA 42kA -- 50kA 50kA 125A -- -- -- -- -- -- -- -- -- -- -- -- 2kA 2.5kA -- -- 42kA 42kA -- -- 50kA 160A -- -- -- -- -- -- -- -- -- -- -- -- -- 2.5kA -- -- -- 42kA -- -- 50kA <= 40A 50A 0.6kA 0.8kA 1kA 1.2kA 1.6kA 30kA 30kA 30kA 36kA 36kA 36kA 1.6kA 2kA 2.5kA 42kA 42kA 42kA 42kA 50kA 50kA 50kA -- 0.8kA 1kA 1.2kA 1.6kA 30kA 30kA 30kA -- 36kA 36kA 1.6kA 2kA 2.5kA 42kA 42kA 42kA 42kA 50kA 50kA 50kA 63A -- -- 1kA 1.2kA 1.6kA 30kA 30kA 30kA -- 36kA 36kA 1.6kA 2kA 2.5kA 42kA 42kA 42kA 42kA 50kA 50kA 50kA 80A -- -- -- 1.2kA 1.6kA -- 30kA 30kA -- 36kA 36kA 1.6kA 2kA 2.5kA 42kA 42kA 42kA 42kA 50kA 50kA 50kA 100A -- -- -- -- 1.6kA -- -- 30kA -- -- 36kA 1.6kA 2kA 2.5kA -- 42kA 42kA 42kA -- 50kA 50kA 125A -- -- -- -- -- -- -- -- -- -- -- -- 2kA 2.5kA -- -- 42kA 42kA -- -- 50kA 160A -- -- -- -- -- -- -- -- -- -- -- -- -- 2.5kA -- -- -- 42kA -- -- 50kA *Where T is mentioned Selectivity is full up until the Icu of the downstream device. IPD INDUSTRIAL PRODUCTS 512 Product Catalogue 2013 Phone: 1300 556 601 www.ipdgroup.com.au DISCRIMINATION & SELECTIVITY SELECTIVE TABLES (RECORD PLUS MOULDED CASE CIRCUIT BREAKERS; TABLE D3 ED. 2C) Upstream FE160N, H & L SMR1 FE250N, H & L LTMD FE250N, H & L SMR1 125A 160A FG400N, H & L SMR1 & 2 250A 250A 350A 400A FG630N, H & L SMR1 & 2 63A 125A 160A 125A 160A 200A 250A 400A 500A 630A <= 16A T T T T T T T T T T T T T T T T 20A T T T T T T T T T T T T T T T T G60 25A T T T T T T T T T T T T T T T T G100 & G25 32A T T T T T T T T T T T T T T T T DM100 & 40A -- T T T T T T T T T T T T T T T DME100 50A -- T T T T T T T T T T T T T T T B/C curve 63A -- T T T T T T T T T T T T T T T Redline 80A -- T T -- T T T T T T T T T T T T HTI 100A -- -- T -- T T T -- T T T T T T T T C curve 125A -- -- T -- -- T T -- T T T T T T T T <= 25A T T T T T T T T T T T T T T T T GPS1BS & 32A T T T T T T T T T T T T T T T T GPS1MS 40A -- T T T T T T T T T T T T T T T Downstream Selectivity limit in kA* In (A) Redline Surion GPS2BS & 50A -- T T T T T T T T T T T T T T T GPS2MS 63A -- T T T T T T T T T T T T T T T Surion <= 25A T T T T T T T T T T T T T T T T GPS1BH & 32A T T T T T T T T T T T T T T T T GPS1MH 40A -- T T T T T T T T T T T T T T T GPS2BH & 50A -- T T T T T T T T T T T T T T T GPS2MH 63A -- T T T T T T T T T T T T T T T Record Plus <= 40A T T T T T T T T T T T T T T T T FD63/160E 50A -- T T T T T T T T T T T T T T T LTM/MO/GTM 63A -- T T T T T T T T T T T T T T T 80A -- -- T -- T T T T T T T T T T T T 100A -- -- T -- -- T T -- T T T T T T T T 125A -- -- -- -- -- T T -- -- T T T T T T T 160A Record Plus <= 40A -- -- -- -- -- -- T -- -- T T T T T T T 36kA 36kA 36kA 42kA 42kA 42kA 42kA 50kA 50kA 50kA T T T T T T T FD63/160S, N 50A -- 36kA 36kA 42kA 42kA 42kA 42kA 50kA 50kA 50kA T T T T T H&L 63A -- 36kA 36kA 42kA 42kA 42kA 42kA 50kA 50kA 50kA T T T T T T LTMD/MO/GTM 80A -- -- 36kA 42kA 42kA 42kA 42kA 50kA 50kA 50kA T T T T T T Record Plus 100A -- -- 36kA -- 42kA 42kA 42kA -- 50kA 50kA T T T T T T 125A -- -- -- -- -- 42kA 42kA -- -- 50kA T T T T T T 160A -- -- -- -- -- -- 42kA -- -- 50kA T T T T T T 36kA 36kA 36kA 42kA 42kA 42kA 42kA 50kA 50kA 50kA T T T T T T <= 40A FE160 N, H & L 50A -- 36kA 36kA 42kA 42kA 42kA 42kA 50kA 50kA 50kA T T T T T T LTM/MO/GTM 63A -- 36kA 36kA 42kA 42kA 42kA 42kA 50kA 50kA 50kA T T T T T T 80A -- 36kA 36kA 42kA 42kA 42kA 42kA 50kA 50kA 50kA T T T T T T 100A -- -- 36kA -- 42kA 42kA 42kA -- 50kA 50kA T T T T T T 125A -- -- -- -- -- 42kA 42kA -- -- 50kA T T T T T T 160A -- -- -- -- -- -- 42kA -- -- 50kA T T T T T T Record Plus 0.8kA 1.8kA 2.2kA 1.3kA 1.6kA 2.5kA 2.5kA 1.8kA 2.2kA 3.5kA T T T T T T FE160 N, H & L <= 40A 63A -- 1.8kA 2.2kA 1.3kA 1.6kA 2.5kA 2.5kA 1.8kA 2.2kA 3.5kA T T T T T T LTMD/SMR1 80A -- 1.8kA 2.2kA 1.3kA 1.6kA 2.5kA 2.5kA 1.8kA 2.2kA 3.5kA T T T T T T 100A -- -- 2.2kA -- 1.6kA 2.5kA 2.5kA -- 2.2kA 3.5kA T T T T T T 125A -- -- -- -- -- 2.5kA 2.5kA -- -- 3.5kA T T T T T T 160A -- -- -- -- -- -- 2.5kA -- -- 3.5kA T T T T T T Record Plus 125A -- -- -- -- -- -- -- -- -- -- 3.5kA 10kA 15kA T T T FE250 N, H & L 160A -- -- -- -- -- -- -- -- -- -- 3.5kA 10kA 15kA T T T LTMD/SMR1 200A -- -- -- -- -- -- -- -- -- -- -- 10kA 15kA T T T 250A -- -- -- -- -- -- -- -- -- -- -- 10kA 15kA T T T Record Plus FG400 N, H & L 250A -- -- -- -- -- -- -- -- -- -- -- 5kA 6kA 5kA 7kA 7kA SMR1/SMR2 400A -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- 7kA TECHNICAL *Where T is mentioned Selectivity is full up until the Icu of the downstream device. IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 513 DISCRIMINATION & SELECTIVITY SELECTIVE TABLES (RECORD PLUS MOULDED CASE CIRCUIT BREAKERS; TABLE D4 ED. 2C) Upstream FK800N, H FK1250N, H & & L SMR1 L SMR1 800A Downstream 1000A FK1600N, H & L SMR1 1250A 600A Selectivity limit in kA* In (A) Redline G60, G100, G25, DM60, DME60, DM100 & DME100 B/C curve ALL T T T T T ALL T T T T T Trip Units ALL T T T T T Trip Units ALL T T T T T Trip Units ALL T T T T T Trip Units ALL T T T T T Trip Units 400A 15kA T T T T 500A 15kA T T T T 630A 15kA T T T T ALL -- 15kA 15kA 25kA 25kA Surion GPS1BS, GPS1MS, GPS2BS, GPS2MS GPS1BH, GPS1MH, GPS2BH & GPS2MH Record Plus FD63/160E, S N & L types LTM/LTMD/MO/GTM Record Plus FE160 N, H & L types LTM/LTMD/MO/GTM/SMR1 Record Plus FE250 V, N, H & L types LTM/LTMD/MO/GTM/SMR1 Record Plus FG400 N, H & L types SMR1/SMR2 Record Plus FG630 N, H & L types SMR1/SMR2 Record Plus FK800 N, H & L types LTM/MO/SMR1e, s & g Trip Units Record Plus FK1250 N, H & L types LTM/MO/SMR1e, s & g Trip Units 1000A -- -- -- 25kA 25kA 1250A -- -- -- 25kA 25kA * Where T is mentioned Selectivity is full up untilthe Icu of the downstream device IPD INDUSTRIAL PRODUCTS 514 Product Catalogue 2013 Phone: 1300 556 601 www.ipdgroup.com.au DISCRIMINATION & SELECTIVITY SELECTIVE TABLES (RECORD PLUS MOULDED CASE CIRCUIT BREAKERS; TABLE D4 ED. 2C) Upstream Mpact + Frame 1 400A 630A Mpact + Frame 2 800A 1000A 1250A 1600A 2000A 2500A 1000A 1250A 1600A Mpact + Frame3 2000A 2500A 3200A 4000A 5000A 6300A Downstream Selectivity limit in kA* In (A) Redline G60,G100,G25, DM60, DME60, DM100 & DME100 B/C curve ALL T T T T T T T T T T T T T T T T T ALL T T T T T T T T T T T T T T T T T Trip Units ALL T T T T T T T T T T T T T T T T T Trip Units ALL T T T T T T T T T T T T T T T T T Trip Units ALL T T T T T T T T T T T T T T T T T Surion GPS1BS, GPS1MS, GPS2BS, GPS2MS GPS1BH, GPS1MH, GPS2BH & GPS2MH Record Plus FD63/160E, S N & L types LTM/LTMD/MO/GTM FE160 N, H & L types LTM/LTMD/MO/GTM/SMR1 Record Plus FE250 V, N, H & L types LTM/LTMD/MO/GTM/SMR1 Record Plus FG400 N, H & L types SMR1/SMR2 Trip Units 250A T T T T T T T T T T T T T T T T T 400A -- -- T T T T T T T T T T T T T T T Record Plus FG630 N, H & L types SMR1/SMR2 Trip Units 400A -- -- T T T T T T T T T T T T T T T 500A -- -- -- T T T T T T T T T T T T T T 630A -- -- -- T T T T T T T T T T T T T T ALL -- -- -- -- T T T T T T T T T T T T T Trip Units 1000A -- -- -- -- -- T T T -- -- T T T T T T T 1250A -- -- -- -- -- -- T T -- -- -- T T T T T T Record Plus FK800 N, H & L types LTM/MO/SMR1e, s & g Trip Units Record Plus FK1250 N, H & L types LTM/MO/SMR1e, s & g Mpact Plus Frame 1 & Frame 2 MPRO plus 17, 18, 30 & 40 Trip Units 400A -- T T T T T T T T T T T T T T T T 630A -- -- -- T T T T T T T T T T T T T T 800A -- -- -- -- T T T T -- T T T T T T T T 1000A -- -- -- -- -- T T T -- -- T T T T T T T 1600A -- -- -- -- -- -- -- T -- -- -- -- T T T T T 2000A -- -- -- -- -- -- -- -- -- -- -- -- -- T T T T 2500A -- -- -- -- -- -- -- -- -- -- -- -- -- -- T T T TECHNICAL * Where T is mentioned Selectivity is full up until the Icu of the downstream device IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 515 DISCRIMINATION & SELECTIVITY SELECTIVE PLUS TABLES (RECORD PLUS MOULDED CASE CIRCUIT BREAKERS; TABLE DB1 ED. 2C) Upstream FDC 63/160 LTM 63A Downstream In (A) Redline G60 &GT10 B/C curve Redline G100 B/C curve Redline GT25 B/C curve Surion GPS1BS & GPS1MS Surion GPS2BS & GPS2MS Surion GPS1BH & GPS1MH GPS2BH & GPS2MH <= 16A 20A 25A 32A 40A 50A 63A <= 16A 20A 25A 32A 40A 50A 63A <= 20A 25A 32A 40A 50A 63A <= 10A 12.5A 16/20A 25/32A 40A 50/63A <= 10A 12.5A 16/20A 25/32A 40A 50/63A <= 10A 12.5A 16/20A 25/32A 40A 50/63A Upstream 6/18 3/18 -----6/18 3/18 ------------------------------ 80A 100A 125A 63A 160A Selectivity limit in kA 6/18 10/18 18/18 6/22 6/18 8/18 18/18 3/22 6/18 6/18 18/18 -3/18 6/18 18/18 -3/18 4/18 18/18 --1.5/18 6/18 -----6/18 10/18 18/18 6/25 6/18 8/18 18/18 3/25 6/18 6/18 18/18 -3/18 6/18 18/18 -3/18 4/18 18/18 --1.5/18 6/18 ---2/18 -------------------------------------------------------------------------------------------------- FDN 63/160 LTMD 63A 80A 100A 30/30 30/30 15/30 10/30 3.5/30 --36/36 36/36 15/36 10/36 3.5/36 --36/42 15/42 10/36 3.5/36 ----42/42 42/42 ---42/42 42/42 42/42 --------- 30/30 30/30 15/30 10/30 10/30 3.5/30 -36/36 36/36 36/36 10/36 10/36 3.5/36 -36/42 15/42 10/36 10/36 3.5/36 ---42/42 42/42 42/42 --42/42 42/42 42/42 42/42 -------- 30/30 30/30 30/30 30/30 15/30 10/30 8/30 36/36 36/36 30/36 30/36 15/36 10/36 8/36 36/42 30/42 36/36 15/36 10/36 8/36 --42/42 42/42 42/42 42/42 -42/42 42/42 42/42 42/42 42/42 ------- Downstream Redline G60 &GT10 B/C curve Redline G100 B/C curve Redline GT25 B/C curve Surion GPS1BS & GPS1MS Surion GPS2BS & GPS2MS Surion GPS1BH & GPS1MH GPS2BH & GPS2MH In (A) <= 16A 20A 25A 32A 40A 50A 63A <= 16A 20A 25A 32A 40A 50A 63A <= 20A 25A 32A 40A 50A 63A <= 10A 12.5A 16/20A 25/32A 40A 50/63A <= 10A 12.5A 16/20A 25/32A 40A 50/63A <= 10A 12.5A 16/20A 25/32A 40A 50/63A IPD INDUSTRIAL PRODUCTS 516 Product Catalogue 2013 FDE 63/160 LTM 80A / Icu of 6/22 6/22 6/22 3/22 3/22 --6/25 6/25 6/25 3/25 3/25 --------------------------- 100A 125A 63A 160A combination in kA at 400-415V AC 10/22 22/22 25/25 8/22 22/22 25/25 6/22 22/22 15/25 6/22 22/22 10/25 4/22 22/22 3.5/25 1.5/22 6/22 ----10/25 25/25 30/30 8/25 25/25 30/30 6/25 25/25 15/30 6/25 25/25 10/30 4/25 25/25 3.5/30 -6/25 --2/25 ---36/36 --15/36 --10/30 --3.5/30 --------------36/36 --36/36 -----------36/36 --36/36 --36/36 ------------------------- FDH 63/160 LTMD 125A 63A 80A 160A Selectivity limit in kA / Icu of 30/30 36/36 36/36 30/30 36/36 36/36 30/30 15/36 15/36 30/30 10/36 10/36 25/30 3.5/36 10/36 22/30 -3.5/36 22/30 --36/36 36/42 36/42 36/36 36/42 36/42 30/36 15/42 36/42 30/36 10/42 10/42 25/36 3.5/42 10/42 22/36 -3.5/42 22/36 --36/42 36/50 36/50 30/42 15/50 15/50 30/36 10/42 10/42 25/36 3.5/42 10/42 22/36 -3.5/42 22/36 ------80/80 80/80 42/42 50/50 50/50 42/42 50/50 50/50 42/42 -50/50 42/42 -----42/42 50/50 50/50 42/42 50/50 50/50 42/42 50/50 50/50 42/42 -50/50 42/42 ---------80/80 80/80 -80/80 80/80 --80/80 ---- Phone: 1300 556 601 FDS 63/160 LTMD 80A 100A 125A 160A 25/25 25/25 15/25 10/25 10/25 3.5/25 -30/30 30/30 30/30 10/30 10/30 3.5/30 -36/36 15/36 10/30 10/30 3.5/30 ---36/36 36/36 36/36 --36/36 36/36 36/36 36/36 -------- 25/25 25/25 25/25 25/25 15/25 10/25 8/25 30/30 30/30 30/30 30/30 15/30 10/30 8/30 36/36 30/36 36/30 15/30 10/30 8/30 --36/36 36/36 36/36 36/36 -36/36 36/36 36/36 36/36 36/36 ------- 25/25 25/25 25/25 25/25 25/25 22/25 22/25 30/30 30/30 30/30 30/30 25/30 22/30 22/30 36/36 30/36 30/30 25/30 22/30 22/30 --36/36 36/36 36/36 36/36 -36/36 36/36 36/36 36/36 36/36 ------- FDL 63/160 LTMD 100A 125A 63A 80A 160A combination in kA at 400-415V AC 36/36 36/36 36/42 36/42 36/36 36/36 36/42 36/42 30/36 30/36 15/42 15/42 36/36 30/36 10/42 10/42 15/36 25/36 3.5/42 10/42 10/36 22/36 -3.5/42 8/36 22/36 --36/42 36/42 36/50 36/50 36/42 36/42 36/50 36/50 30/42 30/42 15/50 15/50 30/42 30/42 10/50 10/50 15/42 25/42 3.5/50 10/50 10/42 22/42 -3.5/50 8/42 22/42 --36/50 36/50 36/65 36/65 30/50 30/50 15/65 15/65 36/42 30/42 10/50 10/50 15/42 25/42 3.5/50 10/50 10/42 22/42 -3.5/50 8/42 22/42 ----150/150 150/150 80/80 80/80 150/150 150/150 50/50 50/50 65/65 65/65 50/50 50/50 65/65 65/65 50/50 50/50 -65/65 50/50 50/50 ----150/150 150/150 50/50 50/50 65/65 65/65 50/50 50/50 65/65 65/65 50/50 50/50 65/65 65/65 50/50 50/50 -65/65 50/50 50/50 ----150/150 150/150 --150/150 150/150 80/80 80/80 150/150 150/150 80/80 80/80 150/150 150/150 80/80 80/80 -150/150 80/80 80/80 --- www.ipdgroup.com.au 100A 125A 160A 36/42 36/42 30/42 36/42 15/42 10/42 8/42 36/50 36/50 30/50 30/50 15/50 10/50 8/50 36/65 30/65 36/50 15/50 10/50 8/50 150/150 150/150 65/65 65/65 65/65 65/65 150/150 65/65 65/65 65/65 65/65 65/65 150/150 150/150 150/150 150/150 150/150 150/150 36/42 36/42 30/42 30/42 25/42 22/42 22/42 36/50 36/50 30/50 30/50 25/50 22/50 22/50 36/65 30/65 30/50 25/50 22/50 22/50 150/150 150/150 65/65 65/65 65/65 65/65 150/150 65/65 65/65 65/65 65/65 65/65 150/150 150/150 150/150 150/150 150/150 150/150 DISCRIMINATION & SELECTIVITY SELECTIVE PLUS TABLE DB1A ED 2C Upstream FDC 63/160 LTM 63A 80A 100A Downstream 63A 80A 100A 125A 160A FDS 63/160 LTMD 63A 80A 100A 160A 125A 160A Selectivity limit in kA / Icu of combination in kA at 240V AC In (A) Redline 125A FDE 63/160 LTM <= 16A 6/18 6/18 10/18 18/18 6/22 6/22 10/22 10/22 25/25 25/25 25/25 25/25 DME100 20A 3/18 6/18 8/18 18/18 3/22 6/22 8/22 10/22 25/25 25/25 25/25 25/25 B/C curve 25A -- 6/18 6/18 18/18 -- 6/22 6/22 10/22 15/25 25/25 25/25 25/25 32A -- 3/18 6/18 18/18 -- 3/22 6/22 10/22 10/25 10/25 25/25 25/25 40A -- 3/18 4/18 18/18 -- 3/22 4/22 10/22 3.5/25 10/25 15/25 25/25 Upstream FDN 63/160 LTMD 63A 80A 100A Downstream 63A 80A 100A 125A 160A In (A) Redline 125A FDH 63/160 LTMD FDL 63/160 LTMD 63A 80A 100A 160A 125A 160A Selectivity limit in kA / Icu of combination in kA at 240V AC <= 16A 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 DME100 20A 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 25/25 B/C curve 25A 15/25 25/25 25/25 25/25 15/25 25/25 25/25 25/25 15/25 25/25 25/25 25/25 32A 10/25 10/25 25/25 25/25 10/25 10/25 25/25 25/25 10/25 10/25 25/25 25/25 40A 3.5/25 10/25 15/25 25/25 3.5/25 10/25 15/25 25/25 3.5/25 10/25 15/25 25/25 SELECTIVE PLUS TABLE DB2A ED 2C Upstream FE160N-LTMD/SMR1 63A 100A FE160H-LTMD/SMR1 125A 160A 63A 100A 125A FE160L-LTMD/SMR1 160A 63A 100A 125A 160A 22/22 Downstream Selectivity limit in kA / Icu of combination in kA at 240V AC In (A) Redline <= 16A 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 DME100 20A 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 B/C curve 25A 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 32A 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 22/22 40A -- 22/22 22/22 22/22 -- 22/22 22/22 22/22 -- 22/22 22/22 22/22 Upstream FE250N-LTMD/SMR1 125A 160A FE250H-LTMD/SMR1 200A 250A 18/18 18/18 18/18 18/18 18/18 Selectivity limit in kA 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 125A 160A 200A FE250L-LTMD/SMR1 125A 160A 200A 250A combination in kA at 240V AC 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 250A 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 Downstream 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 18/18 / Icu of 18/18 18/18 18/18 18/18 18/18 TECHNICAL Redline DME100 B/C curve In (A) <= 16A 20A 25A 32A 40A IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 517 DISCRIMINATION & SELECTIVITY SELECTIVE PLUS TABLE DB2 ED 2C Upstream FE160N-LTMD/SMR1 FE160H-LTMD/SMR1 63A 100A 125A 160A 63A 30/30 30/30 ---36/36 36/36 ---42/42 36/36 -----42/42 42/42 ---42/42 42/42 42/42 --------- 30/30 30/30 30/30 30/30 -36/36 36/36 36/36 36/36 -42/42 36/36 36/36 36/36 ---42/42 42/42 42/42 --42/42 42/42 42/42 42/42 -------- 30/30 30/30 30/30 30/30 30/30 36/36 36/36 36/36 36/36 36/36 42/42 36/36 36/36 36/36 36/36 --42/42 42/42 42/42 42/42 -42/42 42/42 42/42 42/42 42/42 ------- Selectivity limit in kA 30/30 36/36 30/30 36/36 30/30 -30/30 -30/30 -36/36 42/42 36/36 42/42 36/36 -36/36 -36/36 -42/42 50/50 36/36 42/42 36/36 -36/36 -36/36 ----80/80 42/42 50/50 42/42 50/50 42/42 -42/42 ---42/42 50/50 42/42 50/50 42/42 50/50 42/42 -42/42 ------80/80 -80/80 ----- 100A 125A FE160L-LTMD/SMR1 160A 63A 100A 125A 160A 42/42 42/42 42/42 42/42 42/42 50/50 50/50 50/50 50/50 50/50 65/65 50/50 50/50 50/50 50/50 150/150 150/150 65/65 65/65 65/65 65/65 150/150 65/65 65/65 65/65 65/65 65/65 150/150 150/150 150/150 150/150 150/150 150/150 42/42 42/42 42/42 42/42 42/42 50/50 50/50 50/50 50/50 50/50 65/65 50/50 50/50 50/50 50/50 150/150 150/150 65/65 65/65 65/65 65/65 150/150 65/65 65/65 65/65 65/65 65/65 150/150 150/150 150/150 150/150 150/150 150/150 Downstream In (A) Redline G60 &GT10 B/C curve Redline G100 B/C curve Redline GT25 B/C curve Surion GPS1BS & GPS1MS Surion GPS2BS & GPS2MS Surion GPS1BH & GPS1MH GPS2BH & GPS2MH <= 25A 32A 40A 50A 63A <= 25A 32A 40A 50A 63A <= 25A 32A 40A 50A 63A <= 10A 12.5A 16/20A 25/32A 40A 50/63A <= 10A 12.5A 16/20A 25/32A 40A 50/63A <= 10A 12.5A 16/20A 25/32A 40A 50/63A Upstream FE250N-LTMD/SMR1 / Icu of 36/36 36/36 36/36 36/36 -42/42 42/42 42/42 42/42 -50/50 42/42 42/42 42/42 --80/80 50/50 50/50 50/50 --50/50 50/50 50/50 50/50 ---80/80 80/80 80/80 -- combination in kA at 400-415V AC 36/36 36/36 42/42 42/42 36/36 36/36 42/42 42/42 36/36 36/36 -42/42 36/36 36/36 -42/42 36/36 36/36 --42/42 42/42 50/50 50/50 42/42 42/42 50/50 50/50 42/42 42/42 -50/50 42/42 42/42 -50/50 42/42 42/42 --50/50 50/50 65/65 65/65 42/42 42/42 50/50 50/50 42/42 42/42 -50/50 42/42 42/42 -50/50 42/42 42/42 ----150/150 150/150 80/80 80/80 150/150 150/150 50/50 50/50 65/65 65/65 50/50 50/50 65/65 65/65 50/50 50/50 -65/65 50/50 50/50 ----150/150 150/150 50/50 50/50 65/65 65/65 50/50 50/50 65/65 65/65 50/50 50/50 65/65 65/65 50/50 50/50 -65/65 50/50 50/50 ----150/150 150/150 --150/150 150/150 80/80 80/80 150/150 150/150 80/80 80/80 150/150 150/150 80/80 80/80 -150/150 80/80 80/80 --- FE250H-LTMD/SMR1 125A 160A 200A 250A 125A 30/30 30/30 30/30 30/30 30/30 30/30 30/30 30/30 30/30 30/30 36/36 36/36 36/36 30/30 30/30 --42/42 42/42 42/42 42/42 -42/42 42/42 42/42 42/42 42/42 ------- 30/30 30/30 30/30 30/30 30/30 30/30 30/30 30/30 30/30 30/30 36/36 36/36 36/36 30/30 30/30 --42/42 42/42 42/42 42/42 -42/42 42/42 42/42 42/42 42/42 ------- 30/30 30/30 30/30 30/30 30/30 30/30 30/30 30/30 30/30 30/30 36/36 36/36 36/36 30/30 30/30 --42/42 42/42 42/42 42/42 -42/42 42/42 42/42 42/42 42/42 ------- Selectivity limit in kA 30/30 36/36 30/30 36/36 30/30 36/36 30/30 36/36 30/30 36/36 30/30 36/36 30/30 36/36 30/30 36/36 30/30 36/36 30/30 36/36 36/36 42/42 36/36 42/42 36/36 42/42 30/30 36/36 30/30 36/36 ---80/80 42/42 50/50 42/42 50/50 42/42 50/50 42/42 50/50 --42/42 50/50 42/42 50/50 42/42 50/50 42/42 -42/42 ------80/80 -80/80 -80/80 -80/80 160A 200A FE250L-LTMD/SMR1 250A 125A 160A 200A 250A 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 42/42 42/42 42/42 36/36 36/36 150/150 150/150 65/65 65/65 65/65 65/65 150/150 65/65 65/65 65/65 65/65 65/65 150/150 150/150 150/150 150/150 150/150 150/150 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 42/42 42/42 42/42 36/36 36/36 150/150 150/150 65/65 65/65 65/65 65/65 150/150 65/65 65/65 65/65 65/65 65/65 150/150 150/150 150/150 150/150 150/150 150/150 Downstream Redline G60 &GT10 B/C curve Redline G100 B/C curve Redline GT25 B/C curve Surion GPS1BS & GPS1MS Surion GPS2BS & GPS2MS Surion GPS1BH & GPS1MH GPS2BH & GPS2MH In (A) <= 25A 32A 40A 50A 63A <= 25A 32A 40A 50A 63A <= 25A 32A 40A 50A 63A <= 10A 12.5A 16/20A 25/32A 40A 50/63A <= 10A 12.5A 16/20A 25/32A 40A 50/63A <= 10A 12.5A 16/20A 25/32A 40A 50/63A IPD INDUSTRIAL PRODUCTS 518 Product Catalogue 2013 / Icu of 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 42/42 42/42 42/42 36/36 36/36 -80/80 50/50 50/50 50/50 50/50 -50/50 50/50 50/50 50/50 ---80/80 80/80 80/80 80/80 combination in kA at 400-415V AC 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 42/42 42/42 42/42 42/42 42/42 42/42 42/42 42/42 42/42 42/42 42/42 42/42 36/36 36/36 36/36 36/36 36/36 36/36 36/36 36/36 --150/150 150/150 80/80 80/80 150/150 150/150 50/50 50/50 65/65 65/65 50/50 50/50 65/65 65/65 50/50 50/50 65/65 65/65 50/50 50/50 65/65 65/65 --150/150 150/150 50/50 50/50 65/65 65/65 50/50 50/50 65/65 65/65 50/50 50/50 65/65 65/65 50/50 50/50 -65/65 50/50 50/50 ----150/150 150/150 --150/150 150/150 80/80 80/80 150/150 150/150 80/80 80/80 150/150 150/150 80/80 80/80 150/150 150/150 80/80 80/80 150/150 150/150 Phone: 1300 556 601 www.ipdgroup.com.au DISCRIMINATION & SELECTIVITY SELECTIVE PLUS TABLE DB3 ED 2C Upstream In (A) Type & In Downstream Record Plus LTM. LTMD, GTM & MO Record Plus LTM. LTMD, GTM & MO Record Plus LTM. LTMD, & GTM Record Plus LTM. LTMD, & GTM FE160N-LTMD FDC160 FDE160 FDS160 FDN160 FDH160 FDC160 FDE160 FDS160 FDN160 FDH160 FDC160 FDE160 FDS160 FDN160 FDH160 FDC63 FDE63 FDS63 FDN63 FDH63 <= 100A <= 100A <= 100A <= 100A <= 100A 125A 125A 125A 125A 125A 160A 160A 160A 160A 160A 100A 30/30 30/36 30/42 30/50 ----------------- Upstream Record Plus LTM. LTMD, GTM & MO Record Plus LTM. LTMD, & GTM Record Plus LTM. LTMD, & GTM FDC160 FDE160 FDS160 FDN160 FDH160 FDC160 FDE160 FDS160 FDN160 FDH160 FDC160 FDE160 FDS160 FDN160 FDH160 160A 30/30 30/36 30/42 30/50 ----------------- Selectivity limit in kA / Icu of 30/30 30/36 30/36 30/42 30/42 30/50 30/50 30/80 -30/80 30/30 -30/36 -30/42 -30/50 ------------------------ 100A FDC63 FDE63 FDS63 FDN63 FDH63 <= 100A <= 100A <= 100A <= 100A <= 100A 125A 125A 125A 125A 125A 160A 160A 160A 160A 160A 125A 30/30 36/36 42/42 42/50 ----------------- 250A 125A FE160L-LTMD 160A 100A FE250H-LTMD 160A 200A 30/30 36/36 42/42 42/50 -30/30 36/36 42/42 42/50 ------------ Selectivity limit in kA / 30/30 30/30 36/36 36/36 36/36 42/42 42/42 42/42 42/50 42/50 42/50 42/80 --42/80 30/30 30/30 -36/36 36/36 -42/42 42/42 -42/50 42/50 ----30/30 30/30 -36/36 36/36 -42/42 42/42 -42/50 42/50 -----30/30 --36/36 --42/42 --42/50 ----- 125A 160A 125A combination in kA at 400 - 415V AC 30/36 30/36 30/42 30/42 30/42 30/42 30/50 30/50 30/50 30/50 30/65 30/65 30/80 30/80 30/150 30/150 30/80 30/80 30/150 30/150 -30/36 ---30/42 ---30/50 ---30/80 ---30/80 ------------------------------------------- 160A 30/42 30/50 30/65 30/150 30/150 30/42 30/50 30/65 30/150 30/150 ----------- FE250L-LTMD 200A Icu of combination 36/36 36/36 42/42 42/42 42/50 42/50 42/80 42/80 42/80 42/80 36/36 36/36 42/42 42/42 42/50 42/50 42/80 42/80 42/80 42/80 -36/36 -42/42 -42/50 -42/80 -42/80 ----------- 250A 125A 160A in kA at 400 - 415V AC 36/36 42/42 42/42 42/42 42/50 42/50 42/50 42/65 42/65 42/80 42/150 42/150 42/80 42/150 42/150 36/36 -42/42 42/42 -42/50 42/50 -42/65 42/80 -42/150 42/80 -42/150 36/36 --42/42 --42/50 --42/80 --42/80 --36/36 --42/42 --42/50 --42/80 --42/80 --- 200A 250A 42/42 42/50 42/65 42/150 42/150 42/42 42/50 42/65 42/150 42/150 42/42 42/50 42/65 42/150 42/150 ------ 42/42 42/50 42/65 42/150 42/150 42/42 42/50 42/65 42/150 42/150 42/42 42/50 42/65 42/150 42/150 42/42 42/50 42/65 42/150 42/150 TECHNICAL Record Plus LTM. LTMD, GTM & MO 125A FE250N-LTMD In (A) Type & In Downstream FE160H-LTMD IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 519 DISCRIMINATION & SELECTIVITY SELECTIVE PLUS TABLE DB4 ED 2C Upstream FE160N-SMR1 In (A) Downstream FE160H-SMR1 63A 125A 160A 63A 125A FE160L-SMR1 160A 63A 125A 160A Type & In Selectivity limit in kA / Icu of combination in kA at 400 - 415V AC Record Plus FDC63 -- 30/30 30/30 -- 30/36 30/36 -- 36/42 36/42 LTM. LTMD, FDE63 -- 36/36 36/36 -- 30/42 30/42 -- 36/50 36/50 GTM & MO FDS63 -- 36/42 36/42 -- 30/50 30/50 -- 36/65 36/65 FDN63 -- 36/50 36/50 -- 30/80 30/80 -- 36/150 36/150 36/150 36/150 FDH63 -- -- -- -- 30/80 30/80 -- Record Plus FDC160 <= 100A -- -- 30/30 -- -- 30/36 -- -- 36/42 LTM. LTMD, FDE160 <= 100A -- -- 36/36 -- -- 30/42 -- -- 36/50 GTM & MO FDS160 <= 100A -- -- 36/42 -- -- 30/50 -- -- 36/65 FDN160 <= 100A -- -- 36/50 -- -- 30/80 -- -- 36/150 FDH160 <= 100A -- -- -- -- -- 30/80 -- -- 36/150 Record Plus FDC160 125A -- -- -- -- -- -- -- -- -- LTM. LTMD, FDE160 125A -- -- -- -- -- -- -- -- -- & GTM FDS160 125A -- -- -- -- -- -- -- -- -- FDN160 125A -- -- -- -- -- -- -- -- -- FDH160 125A -- -- -- -- -- -- -- -- --- Record Plus FDC160 160A -- -- -- -- -- -- -- -- LTM. LTMD, FDE160 160A -- -- -- -- -- -- -- -- -- & GTM FDS160 160A -- -- -- -- -- -- -- -- -- FDN160 160A -- -- -- -- -- -- -- -- -- FDH160 160A -- -- -- -- -- -- -- -- -- FE250N-SMR1 Upstream In (A) 125A 160A 200A FE250H-SMR1 250A 125A 160A 200A FE250L-SMR1 250A 125A 160A 200A 250A 42/42 Type & In Downstream Selectivity limit in kA / Icu of combination in kA at 400 - 415V AC Record Plus FDC63 30/30 30/30 30/30 30/30 36/36 36/36 36/36 36/36 42/42 42/42 42/42 LTM. LTMD, FDE63 36/36 36/36 36/36 36/36 42/42 42/42 42/42 42/42 50/50 50/50 50/50 50/50 GTM & MO FDS63 42/42 42/42 42/42 42/42 50/50 50/50 50/50 50/50 50/65 50/65 50/65 50/65 FDN63 50/50 50/50 50/50 50/50 50/80 50/80 50/80 50/80 50/150 50/150 50/150 50/150 FDH63 -- -- -- -- 50/80 50/80 50/80 50/80 50/150 50/150 50/150 50/150 Record Plus FDC160 <= 100A -- 30/30 30/30 30/30 -- 36/36 36/36 36/36 -- 42/42 42/42 42/42 LTM. LTMD, FDE160 <= 100A -- 36/36 36/36 36/36 -- 42/42 42/42 42/42 -- 50/50 50/50 50/50 GTM & MO FDS160 <= 100A -- 42/42 42/42 42/42 -- 50/50 50/50 50/50 -- 50/65 50/65 50/65 FDN160 <= 100A -- 50/50 50/50 50/50 -- 50/80 50/80 50/80 -- 50/150 50/150 50/150 FDH160 <= 100A -- -- -- -- -- 50/80 50/80 50/80 -- 50/150 50/150 50/150 Record Plus FDC160 125A -- -- 30/30 30/30 -- -- 36/36 36/36 -- -- 42/42 42/42 LTM. LTMD, FDE160 125A -- -- 36/36 36/36 -- -- 42/42 42/42 -- -- 50/50 50/50 & GTM FDS160 125A -- -- 42/42 42/42 -- -- 50/50 50/50 -- -- 50/65 50/65 FDN160 125A -- -- 50/50 50/50 -- -- 50/80 50/80 -- -- 50/150 50/150 FDH160 125A -- -- -- -- -- -- -- -- -- -- 50/150 50/150 Record Plus FDC160 160A -- -- -- 30/30 -- -- -- 36/36 -- -- -- 42/42 LTM. LTMD, FDE160 160A -- -- -- 36/36 -- -- -- 42/42 -- -- -- 50/50 & GTM FDS160 160A -- -- -- 42/42 -- -- -- 50/50 -- -- -- 50/65 FDN160 160A -- -- -- 50/50 -- -- -- 50/80 -- -- -- 50/150 FDH160 160A -- -- -- -- -- -- -- 50/80 -- -- -- 50/150 IPD INDUSTRIAL PRODUCTS 520 Product Catalogue 2013 Phone: 1300 556 601 www.ipdgroup.com.au DISCRIMINATION & SELECTIVITY SELECTIVE PLUS TABLE DB5 ED 2C Upstream In (A) Downstream FG400N-SMR1 250A 400A FG400H-SMR1 250A FG400L-SMR1 400A 250A FG630N-SMR1 400A 400A FG630H-SMR1 500A Type & In 400A FG630L-SMR1 500A 630A 400A 630A 500A 630A Selectivity limit in kA / Icu of combination in kA at 400-415V AC Record Plus FDC63 30/30 30/30 36/36 36/36 42/42 42/42 30/30 30/30 36/36 36/36 42/42 42/42 LTM. LTMD, FDE63 36/36 36/36 42/42 42/42 50/50 50/50 36/36 36/36 42/42 42/42 50/50 50/50 GTM & MO FDS63 42/42 42/42 50/50 50/50 65/65 65/65 42/42 42/42 50/50 50/50 65/65 65/65 FDN63 50/50 50/50 80/80 80/80 150/150 150/150 50/50 50/50 80/80 80/80 150/150 150/150 FDH63 -- -- 80/80 80/80 150/150 150/150 -- -- 80/80 80/80 150/150 150/150 Record Plus FDC160 30/30 30/30 36/36 36/36 42/42 42/42 30/30 30/30 36/36 36/36 42/42 42/42 LTM. LTMD, FDE160 36/36 36/36 42/42 42/42 50/50 50/50 36/36 36/36 42/42 42/42 50/50 50/50 GTM & MO FDS160 42/42 42/42 50/50 50/50 65/65 65/65 42/42 42/42 50/50 50/50 65/65 65/65 FDN160 50/50 50/50 80/80 80/80 150/150 150/150 50/50 50/50 80/80 80/80 150/150 150/150 Record Plus FDH160 -- -- 80/80 80/80 150/150 150/150 -- -- 80/80 80/80 150/150 150/150 FEN160 50/50 50/50 80/80 80/80 150/150 150/150 50/50 50/50 80/80 80/80 150/150 150/150 LTM.LTMD,GTM FEH160 -- -- 80/80 80/80 150/150 150/150 -- -- 80/80 80/80 150/150 150/150 MO & SMR1 FEN250 -- -- 80/80 80/80 150/150 150/150 50/50 50/50 80/80 80/80 150/150 150/150 FEH250 -- -- 80/80 80/80 150/150 150/150 -- -- 80/80 80/80 150/150 150/150 SELECTIVE PLUS TABLE DB6 ED 2C Upstream In (A) Downstream FK800N-SMR FK800H-SMR FK800L-SMR 800A 800A 800A FK1250N-SMR 1000A 1250A FK1250H-SMR 1000A 1250A FK1250L-SMR 1000A FK1600N-SMR FK1600H-SMR 1250A 1600A 1600A Type&In Selectivity limit in kA / Icu of combination in kA at 400-415V AC Record Plus LTM. LTMD, FDN63 50/50 80/80 100/100 50/50 50/50 80/80 80/80 100/100 100/100 50/50 80/80 GTM & MO FDH63 50/50 80/80 100/100 50/50 50/50 80/80 80/80 100/100 100/100 50/50 80/80 Record Plus FDN160 50/50 80/80 100/100 50/50 50/50 80/80 80/80 100/100 100/100 50/50 80/80 FDH160 50/50 80/80 100/100 50/50 50/50 80/80 80/80 100/100 100/100 50/50 80/80 Record Plus FEN160 50/50 80/80 100/100 50/50 50/50 80/80 80/80 100/100 100/100 50/50 80/80 LTM. LTMD, FEH160 50/50 80/80 100/100 50/50 50/50 80/80 80/80 100/100 100/100 50/50 80/80 GTM, MO FEN250 50/50 80/80 100/100 50/50 50/50 80/80 80/80 100/100 100/100 50/50 80/80 & SMR1 FEH250 -- 80/80 100/100 50/50 50/50 80/80 80/80 100/100 100/100 50/50 80/80 Record Plus FGN400 50/50 80/80 100/100 50/50 50/50 80/80 80/80 100/100 100/100 50/50 80/80 SMR1 & FGH400 50/50 80/80 100/100 50/50 50/50 80/80 80/80 100/100 100/100 50/50 80/80 SMR2 FGN630 15/50 15/80 15/100 50/50 50/50 80/80 80/80 100/100 100/100 50/50 80/80 FGH630 -- 15/80 15/100 -- -- 80/80 80/80 100/100 100/100 50/50 80/80 Record Plus FKN800 -- -- -- 15/50 15/50 15/80 15/80 15/100 15/100 25/50 25/80 SMR1 FKH800 -- -- -- -- -- 15/80 15/80 15/100 15/100 25/50 25/80 FKN1250 -- -- -- -- -- -- -- -- -- 25/50 25/80 TECHNICAL LTM. LTMD, GTM & MO IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 521 FUSE LINK TEMPERATURE DERATING FUSE DE-RATING WITH HIGH ENCLOSURE TEMPERATURES In accordance with the relevant Standards, the rated current of fuses is determined by tests conducted at 35°C ambient air temperature. When fuses are installed within enclosures, it is the temperature within the enclosure (fluid enviroment temperature) which determines whether de-rating is necessary. The effect of high enclosure temperatures on IPD Type T fuses is indicated by the table below. Fuse Nominal Rating (A) 55°C 63 or less 80 100 125 160 200 250 315 355 400 450 500 560 630 670 710 750 800 1000 1250 De-rating not necessary 475 540 600 650 700 725 760 950 1140 IPD INDUSTRIAL PRODUCTS 522 Product Catalogue 2013 Maximum Load Current (A) Versus Fluid Environment Temperature 60°C 65°C 70°C 300 350 390 425 450 520 570 615 665 710 720 900 1070 190 235 285 330 380 405 425 495 540 585 630 670 680 850 1020 Phone: 1300 556 601 75 95 120 145 180 225 270 315 360 380 400 465 510 550 595 630 640 800 960 75°C 70 90 110 135 170 210 255 295 340 360 380 440 480 520 560 590 600 750 900 www.ipdgroup.com.au PROTECTION OF CABLES WITH FUSE LINKS FUSE PROTECTION OF CABLES AGAINST TRANSIENT OVERCURRENTS In some circuits such as the motors, significant transient overcurrents are produced during switching, and it is not economical practice to match cable and fuse-link ratings. For these cases, the cable is chosen for the circuit load condition and the fuse-links are chosen to withstand the transient overcurrent condition. The fuse-links provide only short-circuit current protection to the motor, associated cables and other circuits components. The necessary overload protection is provided by other means such as the motor starter’s thermal overload relay. The short-circuit protection of cables is covered by Section 5 of AS/NZS 3008.1.1:1998 and the Table below shows how fuse-links relate to these requirements in protecting V75 rated PVC insulated copper conductors. Maximum Current-Carrying Capacity (A) Maximum GEC, GE or IPD Fuse-Link Rating (A) Conductor cross-sectional area (mm2) 1 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 “Unenclosed” condition. Ratings according to Table 6, Column 6 of AS/NZS 3008.1.1:1998 13 16 23 31 40 54 72 97 120 145 185 230 265 310 355 425 490 570 660 760 “Enclosed” condition. Ratings according to Table 6, Column 8 of AS/NZS 3008.1.1:1998 11 14 20 26 34 47 62 87 100 125 155 185 220 250 285 340 390 455 530 620 Type T ‘gG’ DIN Type ‘gL’-’gG’ 16 20 35 50 63 80 125 200 250 355 450 630 710 800 1000 1250 1250 1250 1250 1250 16 20 32 40 50 80 125 200 250 355 500 630 800 1000 1000 1000 1000 1000 1000 1000 Notes: 1. Selection of the above fuse-links is based on the formula I2t = K2S2 given in Clause 5.3 of AS/NZS 3008.1.1:1998 where: I = Current which causes the fuse-link to operate in 5 seconds. t = 5 seconds. K = Constant of 111 for PVC insulated copper conductor, for the condition of initial. temperature 75°C and final temperature 160°C (during overcurrent condition). S = Cross-sectional area of the conductor in mm2. TECHNICAL 2. For motor start fuse-links (i.e. those classified and marked ‘gM’) the larger of its dual current ratings is applicable, e.g. 160A for TCP100M160 type. IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 523 GE CONTACTOR SELECTION - LIGHTING CIRCUITS CONTACTORS FOR CONTROL LIGHTING CIRCUITS The characteristics of the most usual lighting systems are as follows: Incandescent lamps The connection current in very high -of the order of 15 times- rated current. Although this is a very short duration, it is only taken into account in order for the contactor connection current not to be exceeded. The power factor is always maintained at 1. Fluorescent lamps The connection current is slightly higher than rated current. The power factor is about 0.5. To improve up to 0.9, compensating capacitors can be used. In such cases, the connection power of the capacitor must be taken into account, the effect of which is appreciably greater on the smaller contactors. High pressure mercury vapour lamps The connection current varies, depending on type, between 1.6 and 2 times the rated current and will hold for between 3 and 5 minutes. The power factor is of the order of 0.6 and this can be improved up to approximately unit value by means of compensating capacitors. In such cases, the connection power of the capacitor must be taken into account, the effect of which is appreciably greater on the smaller contactors. High pressure sodium vapour lamps The connection current values varies, depending on type, between 1.3 and 1.6 times the rated current and will hold between 3 and 5 minutes. The power factor is of the order of 0.45 and this can be improved up to apporximately unit value by means of compensating capacitors. In such cases, the connection power of the capacitor must be taken into account, the effect of which is appreciably greater on the smaller contactors. SELECTION TABLE Maximum number of lamps per phase at 230V Types Incandescent Fluorescent Single arrangement Without compensation Fluorescent Single arrangement With compensation High pressure mercury vapour Without compensation High pressure mercury vapour With compensation High pressure sodium vapour Without compensation High pressure sodium vapour With compensation Metal iodide Without compensation Metal iodide With compensation W A 60 100 200 300 500 1000 2000 15 20 40 65 100 15 20 40 65 100 250 400 700 1000 250 400 700 1000 250 400 1000 250 400 1000 250 400 700 1000 2000 250 400 700 1000 2000 0.27 0.45 0.91 1.36 2.27 4.5 9.1 0.23 0.37 0.44 0.7 1.5 0.23 0.25 0.3 0.45 0.7 2.13 3.25 5.4 7.5 1.3 2.1 3.6 5.3 3 4.4 10.3 1.45 2.5 5.5 2,17 3,48 6,09 8,7 17,39 1,4 2,0 3,6 5,3 10,6 μF 3.5 4.5 4.5 7 18 20 25 40 60 40 45 100 32 45 65 85 100 IPD INDUSTRIAL PRODUCTS 524 Product Catalogue 2013 MCR MC0 MC1 MC2 RL CL00 CL01 CL02 CL25 27 16 8 5 3 1 0 51 32 28 18 8 26 20 20 13 5 5 3 2 1 9 7 5 3 3 2 1 5 4 2 3 2 1 1 0 0 0 0 0 0 37 22 11 7 4 2 1 61 38 33 21 10 32 25 25 14 6 5 3 2 1 9 7 5 3 3 2 1 5 4 2 3 2 1 1 0 6 4 2 2 0 59 35 17 11 7 3 1 79 49 41 26 12 49 38 38 25 9 5 4 2 2 9 7 5 3 4 3 1 5 4 2 4 2 1 1 0 6 5 3 2 0 59 35 17 11 7 3 1 79 49 41 26 12 49 38 38 25 9 6 4 2 2 9 7 5 3 4 3 1 5 4 2 4 3 1 1 1 7 5 3 2 0 59 35 17 11 7 3 1 79 49 41 26 12 49 38 38 25 9 6 4 2 2 11 7 4 3 4 3 1 10 6 3 4 3 1 1 1 7 5 3 2 0 62 40 20 13 8 4 1 88 57 48 30 14 61 48 48 31 11 6 4 2 2 11 7 4 3 4 3 1 10 6 3 4 3 1 1 1 7 5 3 2 1 62 40 20 13 8 4 1 98 61 51 32 16 77 61 61 39 14 8 5 3 2 14 9 5 3 5 4 2 12 7 3 5 3 2 1 1 9 6 3 2 1 70 50 25 17 10 5 2 126 78 66 41 19 94 74 74 47 17 10 6 4 3 18 11 6 4 7 5 2 16 9 4 7 4 2 2 1 11 8 4 3 2 77 60 30 20 12 6 3 155 110 93 58 27 111 87 87 56 21 12 8 5 3 22 14 8 5 9 6 2 20 11 5 9 6 3 2 1 16 11 6 4 2 Phone: 1300 556 601 www.ipdgroup.com.au GE CONTACTOR SELECTION - LIGHTING CIRCUITS DIAGRAMS Single-phase circuit The total number of lamps will be as shown in the table. 3-phase circuit, lamps delta-connected The total number of lamps will be as shown in the table, multiplied by 1.73 and distributed in three equal quantities. 3-phase circuit, lamps star-connected The total number of lamps will be as shown in the table, multiplied by 3 and distributed in three equal quantities. Maximum number of lamps per phase at 230V CL04 CL45 CL06 CL07 CL08 CL09 CL10 CK75C CK08C CK09 CK95 CK10 CK11 CK12 CK13 77 60 30 20 12 6 3 177 125 105 66 30 119 92 92 59 23 14 9 5 4 31 25 16 10 10 7 3 16 14 7 12 8 4 3 2 21 15 8 6 3 85 66 33 22 12 6 3 224 139 118 74 34 134 103 103 66 23 15 10 6 4 27 17 10 7 11 7 3 25 14 6 12 8 4 3 2 21 15 8 6 3 122 73 36 24 14 7 3 237 147 124 78 36 149 115 115 74 29 18 12 7 5 33 20 12 8 13 9 4 30 17 8 12 8 4 3 2 21 15 8 6 3 156 95 47 31 19 9 4 355 221 186 116 54 191 148 148 95 37 27 18 11 8 49 31 18 12 19 13 6 44 26 12 19 12 7 5 2 32 23 13 8 4 191 116 58 38 23 11 5 390 243 204 127 59 232 180 180 115 45 30 20 12 9 55 34 20 13 21 15 6 49 29 13 21 13 7 5 3 36 25 14 9 5 222 133 66 44 26 13 7 434 270 227 142 66 273 212 212 136 53 33 22 13 9 60 37 22 15 24 16 7 54 31 14 23 14 8 6 3 39 28 15 10 5 264 160 79 53 31 16 8 496 309 260 163 76 312 243 243 155 60 36 24 14 10 66 41 24 16 26 18 7 59 34 16 25 16 9 6 3 43 30 17 11 6 284 170 84 56 33 17 8 553 344 289 181 85 347 270 270 173 67 42 28 17 12 77 48 28 19 30 20 9 69 40 18 29 18 10 7 4 50 35 19 13 7 333 200 99 66 39 20 10 790 490 413 259 121 496 385 385 248 96 60 40 24 17 109 87 54 36 43 29 12 57 51 23 41 26 15 10 5 68 48 34 26 22 410 246 122 81 48 24 12 988 614 516 324 151 621 482 482 310 120 75 49 30 21 156 125 78 52 54 37 16 81 72 33 52 32 18 13 6 97 69 48 37 31 555 333 165 110 66 33 16 1245 774 650 409 190 786 610 610 393 152 95 62 38 27 156 125 78 52 68 46 20 81 72 33 65 41 23 16 8 97 69 48 37 31 820 490 240 165 95 50 25 1770 1090 920 570 270 900 700 700 440 170 136 89 54 39 171 137 86 57 96 66 28 90 80 36 93 58 33 23 12 107 76 53 40 34 1320 790 390 260 155 80 40 2340 1460 1220 770 360 1240 960 960 610 240 181 119 71 51 311 249 156 104 129 88 37 163 145 65 124 78 44 31 16 195 138 96 73 62 1550 930 460 300 185 90 45 2740 1700 1430 900 420 1450 1120 1120 720 280 211 138 83 60 311 249 156 104 150 102 44 163 145 65 145 91 52 36 18 195 138 96 73 62 1860 1120 550 370 220 110 55 3910 2430 2045 1280 600 1740 1350 1350 860 330 302 198 119 86 374 299 187 125 214 146 62 195 174 78 207 129 74 52 26 234 166 115 88 75 1860 1120 550 370 220 110 55 4890 3040 2550 1600 750 1740 1350 1350 860 330 377 247 149 107 467 374 234 156 268 183 78 244 217 98 259 162 92 65 32 292 208 144 110 93 TECHNICAL CL03 IPD INDUSTRIAL PRODUCTS Phone: 1300 556 601 15 www.ipdgroup.com.au Product Catalogue 2013 525 RELAY EQUIVALENT SELECTION CHART PANASONIC (National) FINDER Compact Miniature Relay RJ1S G2R-1-SN SJ1S-07L P2RF-05-E RJ2S G2R-2-SN SJ2S-07L P2RF-08-E AHN12 AHNA11P AHN22 AHNA21P 46.61 97.01 46.52 97.02 RU Series 2 POLE Relay DPDT Base 4 POLE Relay 4PDT Base Miniature Rely RU2S SY4S-05E1G2 RU4S SY4S-05E1G2 HC2/HJ2 HC2/HJ2-SFD-K HC4/HJ4 HC4/HJ4-SFD-K 55.32 94.02 55.34 94.04 RH Series 1 POLE Relay SPDT Base 2 POLE Relay DPDT Base 3 POLE Relay 3PDT Base 4 POLE Relay 4PDT Base General Purpose Relay RH1B LY1 SH1B-05C PTF08A-E RH2B LY2 SH2B-05C PTF08A-E RH3B LY3 SH3B-05C PTF11A RH4B LY4 SH4B-05C PTF14A-E HL1 / HC1 HL2-SFD-K / HC2-SFD-S HL2 / HC2 HL2-SFD-K / HC2-SFD-S HC3 HC3-SFD-K HC4 HC4-TSF-K 56.32 96.02 62.33 92.03 56.34 96.04 RR2KP Series 2 POLE Relay DPDT Base Latching Relay RR2KP SR3P-05C G2AK PYF14A(-E) - - RF1V Series 4 POLE Relay Base 6 POLE Relay Base Safety Relay RF1V SF1V-4-07L RF1V SF1V-6-07L - SFS2 / SFS3 SFS4-SFD SFS4 / SFS5 / SFS6 SFS6-SFD - RV8H Series Interface Relay + Base Slim-Line Relay RV8H G2RV - 38.51 RELAY & BASE IDEC (IPD) RJ Series 1 POLE Relay SPDT Base 2 POLE Relay DPDT Base OMRON MY2 PYF08A-E MY4 PYF14A-E Note. This is a guide only for relays that are similar in the market. Consider physical size and detailed specification before making a final decision. IPD INDUSTRIAL PRODUCTS 526 Product Catalogue 2013 Phone: 1300 556 601 www.ipdgroup.com.au