info - Global Fire Control, Inc.

advertisement
Conventional Manual Pull Stations
Indoor/Outdoor/Explosion Proof
GFP-100 Series
Single Action
GFP-200 Series
Double Action
Phone: 888- 673-2900 • Local: 309-755-6352 • Fax: 309-755-8310 • email: inquire@globalfirecontrol.com
DESCRIPTION
The GFP 100 and 200 series manual pull station is
made from a high quality, non-toxic, die cast housing,
manufactured entirely in the U.S.A. Low profile and
smooth edges offer an attractive, yet functional design.
All components are pre-finished with high impact
powder coat paint or have had their surface plated with
brass or chrome to inhibit corrosion.
The GFP 100 & 200 series station fits most project
environments. The standard product is UL listed for
indoor use, but has options listed for outdoor and
hazardous locations. The outdoor option carries a
NEMA 4X rating and the explosion proof listing is for
use in hazardous locations classified Class I, Groups
B, C & D; Class II, Groups E, F & G; and Class III
locations. It is also UL listed for use in weatherproof
applications classified NEMA 4X.
GFP-100 Series
ƒ
Electrically, the GFP 100 & 200 series manual pull
stations are superior with a 10 amp snap action switch,
offered in all possible contact arrangements, including
gold contacts.
ƒ
The GFP 100 & 200 series pull stations can be used
with or without a break glass rod. There is no need for
a special tool to replace the glass rod. They also
come in a wide variety of colors ranging from the
traditional red to safety yellow, blue, green, white,
purple, orange, lime, or black.
ƒ
ƒ
ƒ
FEATURES
ƒ
ƒ
ƒ
ƒ
ƒ
UL listed
CSFM Approved
Single (GFP-100 series) or dual (GFP-200 series)
action operation.
Flush or surface mounting. Surface mounting
indoors requires a GFP-BB or GFP-DBB (extra
deep indoor back box) or equivalent.
Multiple types of environmental applications:
Indoor, Outdoor (“WP” suffix), Corrosion resistant
(“G” suffix), and Explosion Proof (“X” suffix).
Doc# I-05.1001 Rev. 1
ƒ
ƒ
ƒ
For visual indication, there is an option to add an LED
(light emitting diode) to the station. For a red LED,
use the suffix “LEDR”; for Green use “LEDG”; and for
yellow use “LEDY”.
Institutional option (“KO” suffix). This feature adds a
key in the place of the pull handle, allowing only staff
&/or guards to activate an alarm (besides the
automatic fire detection devices, i.e. smoke detectors)
by inserting a key.
Allen wrench or key (“KL” suffix) lock/test/reset.
Pre-signal key switch (“PS” suffix). Possible uses
are: PAS software initial trigger and/or alarm
verification.
Phone Jack (“PJ” suffix). In facilities where firemen
telephone systems are required, the “PJ” option
eliminates the need to have both a remote phone jack
and a manual pull station in the same area in two
different electrical boxes.
Applications in New York City require a New York
Stripe, “NYC” suffix.
Break Glass covers are available. For a cover that
covers the entire manual pull station, use a “BGC”
suffix. For a cover that covers the manual pull
handle, use the “DAH” suffix.
Certain applications may require the use of a manual
pull station for non-fire events like tornado warning,
safety warning, chemical spill, or many more. For
these applications, we provide options for different
colors. Use the suffix “CY” for yellow, “CB” for blue,
“CG” for green, “CW” for white, “CP” for purple, “CO”
for orange, “CL” for lime, and “CB” for black.
Page 1 of 2
GFP 100 & 200 Series
ORDERING INFORMATION (Single Action)
Model No.
GFP-101
GFP-101KL
GFP-101KO
GFP-101T
GFP-101TKL
GFP-101TKO
GFP-102
GFP-102KL
GFP-102KO
GFP-102T
GFP-102TKL
GFP-102TKO
GFP-106
GFP-106KL
GFP-106KO
GFP-106T
GFP-106TKL
GFP-106TKO
Add-ons:
GFP-BB
GFP-DBB
-NYC
-PS
-G
-PJ
-LED(x)
-BGC
-DAH
-C(x)
Manual Pull Stations
ORDERING INFORMATION (Dual Action)
Description
Single action, pig-tail connection, SPST
GFP-101 w/key lock/reset/test
GFP-101 w/key operation (Institutional)
Single action, terminal connection, SPST
GFP-101T w/key lock/reset/test
GFP-101T w/Key operation (Institutional)
Single action, pig-tail connection, DPST
GFP-102 w/key lock/reset/test
GFP-102 w/Key operation (Institutional)
Single action, terminal connection, DPST
GFP-102T w/key lock/reset/test
GFP-102T w/Key operation (Institutional)
Single action, pig-tail connection, DPDT
GFP-106 w/key lock/reset/test
GFP-106 w/Key operation (Institutional)
Single action, terminal connection, DPDT
GFP-106T w/key lock/reset/test
GFP-106T w/Key operation (Institutional)
Surface back box for GFP 100/200
Deep surface back box for GFP 100/200
New York City stripe
Pre-signal key switch
Gold contact 1.0Amp @ 120vac
Phone jack 0.1Amp @24vdc
Light emitting diode (red/green/yellow)
Break glass cover, entire station
Break glass cover, pull handle
Special Color: Use the suffix “CY” for
yellow, “CB” for blue, “CG” for green,
“CW” for white, “CP” for purple, “CO” for
orange, “CL” for lime, and “CB” for black
Model No.
GFP-201
GFP-201KL
GFP-201KO
GFP-201T
GFP-201TKL
GFP-201TKO
GFP-202
GFP-202KL
GFP-202KO
GFP-202T
GFP-202TKL
GFP-202TKO
GFP-206
GFP-206KL
GFP-206KO
GFP-206T
GFP-206TKL
GFP-206TKO
Add-ons:
GFP-BB
GFP-DBB
-NYC
-PS
-G
-PJ
-LED(x)
-BGC
-DAH
-C(x)
Description
Dual action, pig-tail connection, SPST
GFP-201 w/key lock/reset/test
GFP-201 w/key operation (Institutional)
Dual action, terminal connection, SPST
GFP-201T w/key lock/reset/test
GFP-201T w/Key operation (Institutional)
Dual action, pig-tail connection, DPST
GFP-202 w/key lock/reset/test
GFP-202 w/Key operation (Institutional)
Dual action, terminal connection, DPST
GFP-202T w/key lock/reset/test
GFP-202T w/Key operation (Institutional)
Dual action, pig-tail connection, DPDT
GFP-206 w/key lock/reset/test
GFP-206 w/Key operation (Institutional)
Dual action, terminal connection, DPDT
GFP-206T w/key lock/reset/test
GFP-206T w/Key operation (Institutional)
Dimensions
GFP-101: W = 3.2”, L = 4.75”, D = .875”
GFP-201: W = 3.25”, L = 4.75”, D = 1.5”
BGC: W = 5.5”, L = 7.375”, D = 2.25”
-DAH: W = 3.325”, L = 4.75”, D = 1.625”
GFP-101: 15.5oz/440 grams
GFP-201: 1lb 4oz/567 grams
GFP-101 w/DAH: 1lb 9oz/710 grams
BGC (no station): 3lbs./1.36Kg.
Surface back box for GFP 100/200
Deep surface back box for GFP 100/200
New York City stripe
Pre-signal key switch
Gold contact 1.0Amp @ 120vac
Phone jack 0.1Amp @24vdc
Light emitting diode (red/green/yellow)
Break glass cover, entire station
Break glass cover, pull handle
Special Color: Use the suffix “CY” for
yellow, “CB” for blue, “CG” for green,
“CW” for white, “CP” for purple, “CO” for
orange, “CL” for lime, and “CB” for black
SPECIFICATIONS
Electrical
Switch: 10 Amp @ 120vac
Gold Contact: 1.0 Amp @ 120vac
Key Switch: 0.5 Amp @ 30vdc
Phone Jack: 0.1 Amp @ 24vdc
Mounting
Weight
Single gang
Global Fire Control, Inc.
1201 7th Street, Suite 103
East Moline, IL 61244
Phone: 888-673-2900
Local: 309-755-6352
Fax: 309-755-8310
email: inquire@globalfirecontrol.com
Page 2 of 2
Doc# I-05.1001 Rev. 1
Download