Online data sheet FLOWSIC100 Flare MASS FLOW MEASURING DEVICES FLOWSIC100 Flare MASS FLOW MEASURING DEVICES A B C D E F H I J K L M N O P Q R S T Ordering information Type Part no. FLOWSIC100 Flare On request The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications. Our regional sales organization will help you to select the optimum device configuration. Other models and accessories www.sick.com/FLOWSIC100_Flare Product description The FLOWSIC100 Flare product family is characterized by a unique flow-optimized sensor design. This innovative design reduces flow noise and signal drift at very high gas velocities to a minimum. Modern signal processing and highly efficient transducers result in high time resolution of the signal and, therefore, accurate measurement, even at very low gas flow rates. The standard configuration of the system consists of two sender/receiver units or a measuring probe and the MCUP control unit. The MCUP is used for signal input and output, to calculate reference values (standardization), molecular weight, and mass flow, and for the acquisition of gas volume. It also serves as a user-friendly LCD interface. At a glance • High-resolution measurement and short response time • Innovative sensor design for very high gas velocities • Optimum signal transmission even under atmospheric pressure • Remote installation of the control unit up to 1,000 m away • Single and multiple path meter configuration, optional probe type • Field repeatable check procedure of factory zero flow test • Check cycle for automatic self-diagnosis / signal optimization Your benefits • Reliable process control by accurate measurement near to zero flow readings • High measurement availability also under emergency plant operation conditions with high gas velocities up to 120 m/s • Cost saving by remote installation of control unit in safe area • System solution to serve three different flare measurements with a single control unit • Cost saving by minimized installation using single probe version FLOWSIC100 EX-PR • Securing optimal meter performance by continuous monitoring of meter function and extended field diagnostic capabilities ® C 2 US ULTRASONIC GAS FLOW MEASURING DEVICES | SICK Online data sheet | 2016-07-07 15:16:27 Subject to change without notice FLOWSIC100 Flare MASS FLOW MEASURING DEVICES Fields of application • Emission control for billing of CO2 tax • Detection of flare gas leaks • Monitoring of steam injection in flare gas combustion • Monitoring of gas losses • Accurate mass balancing and process optimization Detailed technical data FLOWSIC100 Flare system Measured values Mass flow rate, volumetric flow s. c., volumetric flow, a. c., molecular weight, gas volume and mass, gas velocity, gas temperature, sound velocity Number of measuring paths 1, 2 Measurement principle Ultrasonic transit time difference measurement Measuring medium Mixtures of hydrocarbons with or without H2 content Repeatability 0.2 % at ≥ 10 m/s Resolution 0.001 m/s Uncertainty of measurement Volumetric flow a. c. (1-path measurement): ± 1.5 % ... 5 % Of the measured value (in the range 0.3 m/s up to the upper range value) 1 Volumetric flow a. c. (1-path measurement): ± 0.5 % Of the measured value (in the range 1 m/s up to the upper range value) 1,2 Volumetric flow a. c. (2-path measurement): ± 1 % ... 3 % Of the measured value (in the range 0.3 m/s up to the upper range value) 1 Volumetric flow a. c. (2-path measurement): ± 0.5 % Of the measured value (in the range 1 m/s up to the upper range value) 1,2 Mass flow (1-path measurement): ± 2.5 % ... 5 % Of the measured value (in the range 0.3 m/s up to the upper range value) 1,3 Mass flow (2-path measurement): ± 2 % ... 4 % Of the measured value (in the range 0.3 m/s up to the upper range value) 1,3 Molecular weight: ≤ 2 % Of the measured value (in the range 2 ... 120 kg/kmol) 3 1 2 3 For fully developed flow profiles After flow calibration Hydrocarbon mixtures with < 10% of non-hydrocarbonic content Gas temperature Standard: –70 °C ... +180 °C High-temperature Zone 1: –70 °C ... +280 °C High-temperature Zone 2: –70 °C ... +260 °C Low temperature: –196 °C ... +100 °C Not for FLOWSIC100 EX/EX-RE Zone 1 and Class I, Division 1 Operating pressure –0.5 bar (g) ... 16 bar (g) Ambient temperature Sensors, ignition group IIC T4: –40 °C ... +70 °C Sensors, ignition group IIC T4: –50 °C ... +70 °C Optional 2016-07-07 15:16:27 | Online data sheet Subject to change without notice ULTRASONIC GAS FLOW MEASURING DEVICES | SICK 3 FLOWSIC100 Flare MASS FLOW MEASURING DEVICES A B C D E F Sensors, ignition group IIC T6: –40 °C ... +55 °C Sensors, ignition group IIC T6: –50 °C ... +55 °C Optional Storage temperature –40 °C ... +70 °C –50 °C ... +70 °C Optional Ambient humidity ≤ 95 % Relative humidity Electrical safety CE FLOWSIC100 EX-S Measuring ranges Gas velocity 0.03 ... 120 m/s Measuring span 4000 : 1 Nominal pipe size 1-path measurement: 4 ″ ... 24 ″ Depending on gas composition 2-path measurement: 12 ″ ... 24 ″ Depending on gas composition H I J K L M N O P Q R S T Ex-approvals IECEx Ex d [ia] IIC T4 Optional: temperature class T6; ex zone 0 for ultrasonic transducers ATEX II 1/2G Ex d [ia] IIC T4 II 1/2G Ex de [ia] IIC T4 Optional: temperature class T6; ex zone 0 for ultrasonic transducers II 3 G Ex nA II T4 Gc NEC/CEC (US/CA) Cl I, Div1 Group B, C, D T4 Ex/AEx d [ia] IIB + H2 T4 Optional: temperature class T6 Cl I, Div2 Group A, B, C, D T4 Ex/AEx nA [ia] IIC T4 Enclosure rating ATEX zone 1 with terminal box IP 65 ATEX zone 1 without terminal box IP 65 / IP 67 ATEX zone 2 with terminal box IP 65 NEC/CEC (US/CA) Enclosure type 4, IP65 Dimensions (W x H x D) For details see dimensional drawings Weight ≤ 11 kg FLOWSIC100 EX/EX-RE Measuring ranges Gas velocity 0.03 ... 120 m/s Measuring span 4000 : 1 Nominal pipe size 1-path measurement: 8 ″ ... 72 ″ Depending on gas composition 2-path measurement: 12 ″ ... 72 ″ Depending on gas composition Ex-approvals IECEx Ex d IIC T4 Optional: temperature class T6 4 ULTRASONIC GAS FLOW MEASURING DEVICES | SICK Online data sheet | 2016-07-07 15:16:27 Subject to change without notice FLOWSIC100 Flare MASS FLOW MEASURING DEVICES ATEX II 2G Ex d IIC T4 II 2G Ex de IIC T4 Optional: temperature class T6 II 3 G Ex nA IIC T4 Gc NEC/CEC (US/CA) Cl I, Div1 Group B, C, D T4 Ex/AEx d IIB + H2 T4 Optional: temperature class T6 Cl I, Div2 Group A, B, C, D T4 Ex/AEx nA IIC T4 Enclosure rating ATEX zone 1 with terminal box IP 65 ATEX zone 1 without terminal box IP 65 / IP 67 Version for Ex-zone 2 IP 65 NEC/CEC (US/CA) Enclosure type 6, IP65/67, single seal Dimensions (W x H x D) For details see dimensional drawings Weight ≤ 14 kg FLOWSIC100 EX-PR Measuring ranges Gas velocity 0.03 ... 90 m/s Measuring span 3000 : 1 Nominal pipe size 1-path measurement: 12 ″ ... 72 ″ Depending on gas composition 2-path measurement: 18 ″ ... 72 ″ Depending on gas composition Ex-approvals IECEx Ex d [ia] IIC T4 Optional: temperature class T6; ex zone 0 for ultrasonic transducers ATEX II 1/2G Ex d [ia] IIC T4 II 1/2G Ex de [ia] IIC T4 Optional: temperature class T6; ex zone 0 for ultrasonic transducers II 3 G Ex nA IIC T4 Gc NEC/CEC (US/CA) Cl I, Div1 Group B, C, D T4 Ex/AEx d [ia] IIB + H2 T4 Optional: temperature class T6 Cl I, Div2 Group A, B, C, D T4 Ex/AEx nA [ia] IIC T4 Enclosure rating ATEX zone 1 with terminal box IP 65 ATEX zone 1 without terminal box IP 65 / IP 67 Version for Ex-zone 2 IP 65 NEC/CEC (US/CA) Enclosure type 4, IP65 Dimensions (W x H x D) For details see dimensional drawings Weight ≤ 32 kg MCUP control unit Description Unit for controlling the sender/receiver units and offsetting, evaluating, and outputting measured value data Ambient temperature MCUP control unit (non-Ex): –40 °C ... +60 °C 2016-07-07 15:16:27 | Online data sheet Subject to change without notice ULTRASONIC GAS FLOW MEASURING DEVICES | SICK 5 FLOWSIC100 Flare MASS FLOW MEASURING DEVICES A B C D E F MCUP control unit (Cl I, Div2, Zone 2, 115/230 –25 °C ... +60 °C V AC): MCUP control unit (Cl I, Div2, Zone 2, 24 V DC): –40 °C ... +60 °C MCUP control unit (Cl I, Div1, Group A, B, C, D): –25 °C ... +50 °C MCUP control unit (Ex zone 1): –40 °C ... +55 °C Ex-approvals IECEx Ex de IIC T6 ATEX II 2G Ex de IIC T6 II 3 G Ex nA II T4 NEC/CEC (US/CA) CSA Cl 1, Div2; Cl1, Zone 2 Group A, B, C, D T4 Ex/AEx nA IIC T4 Enclosure rating Version for Ex-zone 1 IP 66 Version for Ex-zone 2, Div2, Div1 Enclosure type 4 or 4X/IP 66 Version for non-Ex areas IP 66 19″-type IP 20 H I J K L M N O P Q R S T Analog outputs 1 output: 0/2/4 ... 22 mA, 500 Ω According to NAMUR NE43 (Standardization Association for Measurement and Control); up to 7 outputs when I/O modules are used (optional) Analog inputs 2 inputs: 0 ... 5 V 0 ... 10 V Or 2 inputs: 0 ... 20 mA Without galvanic isolation; up to 6 outputs if using I/O modules (option) Digital outputs 5 relay contacts: 48 V DC, 1 A Potential-free; for status signals; up to 7 outputs if using I/O modules (option); Pulse/frequency output (option) 5 relay contacts: / 30 V DC, 1 A MCUP for Zone 2/Div2; potential-free; for status signals; up to 7 outputs if using I/O modules (option); Pulse/frequency output (option) Digital inputs 2 inputs: For connection of potential-free contacts Interfaces USB 1.1 (virtual COM port; service interface) RS-232 (service interface) RS-485 (only Ex-versions) Digital transmitter interface (via optional interface module) Interface module (option) Bus protocol Ethernet TCP/IP (via optional interface module) Modbus (via optional interface module) HART (via optional interface module) PROFIBUS DP (via optional interface module) Foundation Fieldbus (via optional interface module) Modbus TCP (via optional interface module) Indication LC display Status LEDs: "Power", "Maintenance request" and "Fault" Operation Via LC-display or software SOPAS ET Dimensions (W x H x D) For details see dimensional drawings Weight ≤ 22 kg Depending on version 6 ULTRASONIC GAS FLOW MEASURING DEVICES | SICK Online data sheet | 2016-07-07 15:16:27 Subject to change without notice FLOWSIC100 Flare MASS FLOW MEASURING DEVICES Electrical connection Voltage Version for non-Ex areas: 90 ... 250 V AC Version for Ex-zone 1: 100 ... 240 V AC Version for Ex-zone 2, Div2, Div1: 115 V AC / 230 V AC Version for Ex-zone Cl1, Div1: 100 ... 240 V Versions with 24 V DC available as an option Frequency 50 Hz / 60 Hz Power consumption ≤ 20 W Options Interface module(s) I/O module(s) Dimensional drawings (Dimensions in mm (inch)) FLOWSIC100 EX-S, sender/receiver unit, not retractable 150 (5.91) 271 (10.67) 150 (5.91) 115.5 155.5 (4.55) (6.12) 120.7 (4.75) A 120 A 1 A 150 (5.91) 171.5 (6.75) 2 ① Sender/receiver unit (analog) for ATEX Ex zone 1 and Ex zone 2, and CSA Cl I, Div 1/Div 2 ② Sender/receiver unit (digital) for ATEX Ex zone 2 FLOWSIC100 EX-S, sender/receiver unit, retractable 332 (13.07) 287.5 (11.32) 115.5 172 (4.55) (6.77) 120.7 332 (13.07) (4.75) A 120 A 150 (5.91) 188 (7.40) A 2 1 ① Sender/receiver unit (analog) for ATEX Ex zone 1 and Ex zone 2, and CSA Cl I, Div 1/Div 2 ② Sender/receiver unit (digital) for ATEX Ex zone 2 FLOWSIC100 EX, sender/receiver unit, not retractable (6.12) 120.7 (4.75) A A (6.00) 155.5 (4.55) 120 (4.72) 115.5 198 (7.80) 152.4 267.5 (10.53) Sender/receiver unit (digital) with electronic module for ATEX zone 2 2016-07-07 15:16:27 | Online data sheet Subject to change without notice ULTRASONIC GAS FLOW MEASURING DEVICES | SICK 7 FLOWSIC100 Flare MASS FLOW MEASURING DEVICES 267.5 (10.53) 511.5 (20.14) 115.5 152 131.5 (4.55) (5.98) (5.18) 120.7 (4.75) 380 (14.96) (6.00) A 152.4 120 (4.72) A Sender/receiver unit (digital) with electronic module for ATEX zone 2 FLOWSIC100 EX-PR, sender/receiver unit, not retractable 273.5 (10.77) 115.5 158 (6.22) (4.55) 517/647 (20.35/25.47) 220/350 Ø 152.4 (6.00) 297 (11.69) (8.66/13.78) A Ø 190 (7.48) 120 (4.72) A Sender/receiver unit (digital) with electronics unit for ATEX Zone 2: Nominal length 220 mm for pipe diameter up to 48″; nominal length 350 mm for pipe diameter > 48″ up to 72″ FLOWSIC100 EX-PR, sender/receiver unit, retractable 273.5 (10.77) 115.5 158 (6.22) 1,039/1,169 (40.91/46.02) 342 (13.46) Ø 152.4 400/530 (15.75/20.87) (6.00) 297 (11.69) (4.55) Ø 190 (7.48) A 120 (4.72) A 115.5 (4.55) 1 163 (6.42) Sender/receiver unit (digital) with electronics unit for ATEX Zone 2: Nominal length 400 mm for pipe diameter up to 48″; nominal length 530 mm for pipe diameter > 48″ up to 72″ Electronics units of sender/receiver units (digital) 163 (6.42) H I J K L M N O P Q R S T FLOWSIC100 EX-RE, sender/receiver unit, retractable 120 A B C D E F 159.5 (6.28) 2 93 3 (3.66) ① Electronics unit of sender/receiver unit (digital) for ATEX zone 2 ② Electronics unit of sender/receiver unit (digital) for ATEX zone 1 ③ Electronics unit of sender/receiver unit (digital) for ATEX/IECEx zone 1 and CSA Cl I, Div 1/Div 2 8 ULTRASONIC GAS FLOW MEASURING DEVICES | SICK Online data sheet | 2016-07-07 15:16:27 Subject to change without notice FLOWSIC100 Flare MASS FLOW MEASURING DEVICES MCUP control unit; wall-mounting enclosure, compact version (for non-hazardous areas only) 210 (8.27) 300 (11.81) 320 (12.60) 340 (13.39) 160 (6.30) 120 (4.72) Meas MCUP control unit; wall-mounting enclosure, medium version 356 (14.02) 330 (12.99) 221 (8.70) 300 (11.81) 320 (12.60) 242 (9.53) 300 (11.81) 330 (12.99) Ø 10 (0.39) ① Wall-mounting enclosure for ATEX Ex-zone 2 and non-hazardous areas ② Wall-mounting enclosure for CSA Cl I, Div2 2016-07-07 15:16:27 | Online data sheet Subject to change without notice ULTRASONIC GAS FLOW MEASURING DEVICES | SICK 9 FLOWSIC100 Flare MASS FLOW MEASURING DEVICES Ø 290 (11.42) 227 (8.94) 210 (8.27) 447 (17.60) 210 (8.27) 360 (14.17) 150 (5.91) MCUP control unit; wall-mounting enclosure Ex d/Ex e, stainless steel, ATEX Zone 1 470 (18.50) 426 (16.77) 360 (14.17) 12 265 (10.43) 176.5 (6.95) 550.5 (21.67) 275 (10.83) 360 (14.17) (0.47) Ø 18 (0.71) 150 (5.91) MCUP control unit; 19″-rack enclosure (for non-hazardous areas only) 57 10 (2.24) (5.22) H I J K L M N O P Q R S T MCUP control unit; wall-mounting enclosure Ex d/Ex e, size 4, aluminum, ATEX zone 1 132.5 A B C D E F 466 (18.35) 260 (10.24) 483 (19.02) ULTRASONIC GAS FLOW MEASURING DEVICES | SICK Online data sheet | 2016-07-07 15:16:27 Subject to change without notice FLOWSIC100 Flare MASS FLOW MEASURING DEVICES Mounting nozzle for FLOWSIC100 EX A 152.4 R (6.00) A 181 (7.13) 120.7 (4.75) Mounting nozzle for FLOWSIC100 EX-PR A Ø 190 (7.48) A R Ø 152.4 182 (7.17) (6.00) Mounting nozzle for FLOWSIC100 EX-S R (6.00) A 152.4 A 133.5 120.7 (5.26) (4.75) (4.75) Ø 120.7 (6.00) Ø 152.4 246 (9.69) Ball valve, 2″ version, for high temperatures 178 (7.01) Ø 50 (1.97) For FLOWSIC100 EX-S, EX and EX-RE 2016-07-07 15:16:27 | Online data sheet Subject to change without notice ULTRASONIC GAS FLOW MEASURING DEVICES | SICK 11 FLOWSIC100 Flare MASS FLOW MEASURING DEVICES (4.75) Ø 120.7 (6.00) Ø 152.4 227 (8.94) 178 (7.01) Ø 50 (1.97) For FLOWSIC100 EX-S, EX and EX-RE Ball valve, 2″ version, for low temperatures (4-.75) 120.7 152.4 (6.00) 180 (7.09) 328 (12.91) 178 (7.01) Ø 50 (1.97) (6.00) Ø 152.4 (7.50) For FLOWSIC100 EX-S, EX and EX-RE Ball valve, 3″ version, for high temperatures Ø 190.5 H I J K L M N O P Q R S T Ball valve, 2″ version, for standard temperatures 312 (12.28) A B C D E F 203 (8.00) Ø 76 (3.00) For FLOWSIC100 EX-PR 12 ULTRASONIC GAS FLOW MEASURING DEVICES | SICK Online data sheet | 2016-07-07 15:16:27 Subject to change without notice FLOWSIC100 Flare MASS FLOW MEASURING DEVICES (6.00) Ø 152.4 (7.50) Ø 190.5 283 (11.14) Ball valve, 3″ version, for standard temperatures 203 (8.00) Ø 76 (3.00) For FLOWSIC100 EX-PR Ball valve, 3″ version, for low temperatures 203 (7.99) 209 (8.23) Ø 190 (7.48) 469.5 (18.48) 181.5 (7.15) 450 (17.72) Ø 80 (3.15) For FLOWSIC100 EX-PR 2016-07-07 15:16:27 | Online data sheet Subject to change without notice ULTRASONIC GAS FLOW MEASURING DEVICES | SICK 13 Online data sheet SICK at a glance SICK is one of the leading manufacturers of intelligent sensors and sensor solutions for industrial applications. A unique range of products and services creates the perfect basis for controlling processes securely and efficiently, protecting individuals from accidents and preventing damage to the environment. We have extensive experience in a wide range of industries and understand their processes and requirements. With intelligent sensors, we can deliver exactly what our customers need. In application centers in Europe, Asia and North America, system solutions are tested and optimized in accordance with customer specifications. All this makes us a reliable supplier and development partner. Comprehensive services complete our offering: SICK LifeTime Services provide support throughout the machine life cycle and ensure safety and productivity. For us, that is “Sensor Intelligence.” Worldwide presence: Contacts and other locations – www.sick.com SICK AG |Waldkirch|Germany|www.sick.com