PRELIMINARY ParaLink-1.6G SEPTEMBER 2001 Features n Separate transmitter and receiver modules n Data rate up to 1.6Gbps per channel with total throughput 19 Gbps n 12 Asynchronous AC coupled channels n Link distance up to 200m over 62.5 µm multimode ribbon fiber n 3.3V low power operation n LVDS electrical interface Applications n Digital optical cross connect switches n Add/Drop multiplexers n Terabit routers n 10G-VSR n SAN switches n Server clusters and high performance computers Description The Molex ParaLink is a high speed parallel optical link. It consists of separate 12 channel parallel transmitter and receiver modules. The link is completed by connecting 12 fiber multi-mode ribbon cable. The optical interface is a MT ferrule based SMC connector. The 86991-0200 & 86991-0300 series operate up to 1.6Gbps data rate per channel. The transmitter module consists of a 12 channel VCSEL array and parallel laser driver circuitry which converts 12 parallel electrical data inputs to 12 parallel optical data output signals. The module is compatible with low voltage differential signal data inputs (LVDS). The receiver module inputs 12 parallel optical signals and converts these into 12 parallel LVDS electrical data signals through an PIN photodetector array and receiver circuitry. Molex ParaLink modules are fully compatible and interoperable with Infineon PAROLI modules. Ordering Information Molex Part Number 86991-0200 86991-0300 Data Rate (Gbps) 1.6 x 12 1.6 x 12 TX/RX TX RX Data Voltage Level LVDS LVDS Block Diagram LE TRANSMITTER x12 Data In -LE x12 X12 LVDS Input Stage RECEIVER Laser Driver x12 VCSEL Array Laser Control x12 Pin x12 Diode Array Amp Gain Amp x12 LVDS x12 Output Stage Data Out x12 SD1 Signal Detect -SD12 Vin -RESET MOLEX FIBER OPTICS DIVISION 86001-0152, rev.1.2 LCU ENSD 5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A!-FIBER or 1-630-512-8787 USA/30MFO/2001.09 OEN Web: www.molex.com 1 PRELIMINARY ParaLink-1.6G SEPTEMBER 2001 Transmitter Specifications Molex p/n 86991-0200 Maximum Ratings Parameter Supply Voltage Data Control Input Levels LVDS Input Differential Voltage Operating Case Temperature Storage Ambient Temperature Symbol V V IN |V ID| Tcase Tstorage Min -0.3 -0.5 Symbol Vcc Icc W DR V LVCMOSOL V LVCMOSOH ILVCMOSI ILVCMOSOH ILVCMOSOL Rin |II| Pout λc ∆λ tR tF JD JR JT tCSK ER RIN Min 3.0 Typ Max 4.5 Vcc+0.5 2.0 80 100 Unit V V V C C Comments Vcc-Vee Typ 3.3 350 1.2 Max 3.6 450 1.6 1600 0.4 Unit V mA W Mbps V V µA mA mA Ω mA dBm nm nm ps ps ps ps ps ps dB dB/Hz Comments 0 -20 Electro-optical Characteristics Parameter Supply Voltage Supply Current Power Consumption Data Rate per Channel LVCMOS Output Voltage Low LVCMOS Output Voltage High LVCMOS Output Current High/Low LVCMOS Output Current High LVCMOS Output Current Low LVDS Differential Input Impedance LVDS Input Differential Current Average Output Power Center Wavelength Spectral Width (RMS) Optical Rise Time Optical Fall Time Deterministic Jitter Random Jitter (14σ) Total Jitter Channel to Channel Skew Extinction Ratio Relative Intensity Noise Note 1 2.5 -500 500 0.5 4.0 120 5.0 -3.0 860 0.85 400 400 125 144 238 75 80 -11.0 820 6.0 -116 12 channels Source current Sink current LVDS Input Stage Max is class 1 eye safety limit 20%-80% level, measured using gigabit ethernet filter 50% duty cycle output pattern dynamic Note 1: min data rate, DRmin depends on the disparity, D, of the data stream. The running disparity of a data stream is the difference of the number of 1s and 0s of that data stream. The disparity D is the maximum value of the running disparity for all possible starting points in the data stream. Running disparity is set to zero at the starting point. Run length is the maximum number of consecutive 1s or 0s in the data stream. For the transmitter DR min = D(Mbps) Timing Specifications Parameter -RESET on delay time -RESET off delay time -RESET low duration Symbol t1 t2 t3 Min. Max. 100 ms 50 µs 10 µs Vcc 3.6V 3.0V 2.0V -RESET 0.8V t3 Data MOLEX FIBER OPTICS DIVISION 86001-0152, rev.1.2 data invalid data valid t1 5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A!-FIBER or 1-630-512-8787 USA/30MFO/2001.09 t2 Web: www.molex.com 2 PRELIMINARY ParaLink-1.6G SEPTEMBER 2001 Receiver Specifications p/n 86991-0300 Maximum Ratings Parameter Supply Voltage Data Control Input Levels LVDS Input Differential Voltage Operating Case Temperature Storage Ambient Temperature Symbol V V IN |V ID| Tcase Tstorage Min -0.3 -0.5 Symbol Vcc Icc W DR V LVDSOL V LVDSOH |V OD| Vos tR/tF ILVDSOL ILVDSOH ILVCMOSI ILVCMOSOH ILVCMOSOL tCSK Pin PSAT PSDA PSDD PSDA - PSDD A RL Min 3.0 Typ Max 4.5 Vcc+0.5 2.0 80 100 Unit V V V C C Comments Vcc-Vee Typ 3.3 250 0.8 Max 3.6 350 1.3 1600 Unit V mA W Mbps mV mV mV MV ps mV mV µA mA mA ps dBm dBm dBm Comments 0 -20 Electro-optical Parameters Parameter Supply Voltage Supply Current Power Consumption Data Rate per Channel LVDS Output Low Voltage LVDS Output High Voltage LVDS Output Differential Voltage LVDS Output Offset Voltage LVDS Rise/Fall Time LVCMOS Output Voltage Low LVCMOS Output Voltage High LVCMOS Output Current High/Low LVCMOS Output Current High LVCMOS Output Current Low Channel to Channel Skew Receiver Sensitivity Receiver Saturation Signal Detect Assert Level Signal Detect Reassert Level Signal Detect Hysteresis Return Loss of Receiver Note 1 925 1475 400 1275 400 400 250 1125 2500 -500 500 0.5 4.0 75 -18 -3 -19 -28 1.0 12 2.5 4.0 12 channels Source current Sink current BER=10-12, ER = infinite BER=10-12, ER = infinite dB dB Note 1: min data rate, DRmin depends on the disparity, D, of the data stream. The running disparity of a data stream is the difference of the number of 1s and 0s of that data stream. The disparity D is the maximum value of the running disparity for all possible starting points in the data stream. Running disparity is set to zero at the starting point. Run length is the maximum number of consecutive 1s or 0s in the data stream. For the receiver DR min = 8xD(Mbps) Receiver Timing Parameter Signal detect deassert Signal detect assert LVDS Output enable off delay time LVDS Output enable on time Symbol t1 t2 t3 Min. 10 µs 10 µs 20 ns t4 20 ns Max. Data Out 1, 12 t2 t1 Signal Detect 1 Signal Detect 12 Output Enable 2.0V 0.8V Data Out t3 MOLEX FIBER OPTICS DIVISION 86001-0152, rev.1.2 5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A!-FIBER or 1-630-512-8787 USA/30MFO/2001.09 t4 Web: www.molex.com 3 PRELIMINARY SEPTEMBER 2001 ParaLink-1.6G Laser Safety This optoelectronic transmitter is a Class 1 Laser Product that complies with 21 CFR Subchapter J. According to classification methods specified in IEC 60825-1, Amendment 2, the product has an IEC laser classification of 1M. The transmitter contains a VCSEL laser diode array which emits laser radiation in the range of 820 to 860 nm. Light from the laser diode is attenuated so that the optoelectronic transmitter conforms to the Class 1 limit. To avoid possible exposure to laser radiation, do not open or alter the sealed housing of the product. No maintenance or service of the product may be performed. Caution: The use of optical instruments with this product will increase eye hazard. Invisible Laser Radiation. Do not stare into beam or view directly with optical instruments. To ensure laser safety for all input data patterns, each channel is controlled internally and will be switched off if laser safety limits are exceeded. A channel alerter switches the respective data channel output off if the input duty cycle permanently exceeds 57%. The alerter will not disable the channel below an input duty cycle of 57% under all circumstances. The minimum alerter response time is 1 us with a constant high input. This means in the input data bit stream, ones (1s) in excess of a 57% duty cycle, consecutive or non-consecutive, the time interval of excessive high input must not exceed 1 us, otherwise the respective channel will be switched off. The alterter switches the respective channel from off to on without the need of resetting the module. All of the channel alerters operate independently. This means an alert within a channel does not affect the other channels. To decrease the power consumption of the module, the unused channel inputs can be tied to high input level. This allows a portion of the supply current in this channel to be shut down by the corresponding alerter. On the transmitter module pin #67 and #68, laser enable high and laser enable low, can be used to as an input for connection with an Open Fiber Control (OFC) circuit to configure an IEC Class 1 link. MOLEX FIBER OPTICS DIVISION 86001-0152, rev.1.2 5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A!-FIBER or 1-630-512-8787 USA/30MFO/2001.09 Web: www.molex.com 4 PRELIMINARY ParaLink-1.6G SEPTEMBER 2001 Pin Out Description Pin Numbering System 1.6Gbps Receiver, p/n 86991-0300 Pin# 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Name GND Vcc Vcc NC OEN SD1 Vcco GND NC GND GND GND Dout1+ Dout1GND GND Dout2+ Dout2GND GND Dout3+ Dout3GND GND NC Dout4+ Dout4GND Dout5+ Dout5GND GND Dout6+ Dout6GND GND Logic LVCMOS In LVCMOS Out LVDS Out LVDS Out LVDS Out LVDS Out LVDS Out LVDS Out LVDS Out LVDS Out LVDS Out LVDS Out LVDS Out LVDS Out Pin# 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 Name Dout7Dout7+ GND GND Dout8+ Dout8GND GND GND Dout9+ Dout9NC GND GND Dout10+ Dout10GND GND Dout11+ Dout11GND GND Dout12+ Dout12GND GND GND NC GND Vcoo -SD12 ENSD NC Vcc Vcc GND 86001-0152, rev.1.2 Pin# 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 LVDS Out LVDS Out LVDS Out LVDS Out LVDS Out LVDS Out LVDS Out LVDS Out LVDS Out LVDS Out LVCMOS Out LVCMOS In Receiver Pin Nomenclature Vcc Power supply of pre-amp and analog circuitry Vcoo Power supply of output stage Doutx+ Data channel output non-inverted DoutxData channel ouotput inverted GND Ground NC No connection OEN Output enable, high=normal operation Low = sets all data outputs ENSD High = SD1 and SD12 function enabled Low = SD1 and SD12 permanent active SD1 signal detect on fiber 1 High = signal of sufficient AC power on fiber 1 Low = signal on fiber 1 is insufficient SD12 Signal detect on fiber 12 High = signal of sufficient AC power on fiber 12 Low = signal on fiber 12 is insufficient. MOLEX FIBER OPTICS DIVISION 1.6Gbps Transmitter, p/n 86991-0200 Logic LVDS Out LVDS Out Name Vcc NC NC NC NC LCU GND GND NC NC GND GND Din1Din1+ GND GND Din2Din2+ GND GND Din3Din3+ GND GND NC Din4Din4+ GND Din5Din5+ GND GND Din6Din6+ GND GND Logic LVCMOS Out LVDS In LVDS In LVDS In LVDS In LVDS In LVDS In LVDS In LVDS In LVDS In LVDS In LVDS In LVDS In Pin# 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 Name Din7Din7+ GND GND Din8Din8+ GND GND GND Din9Din9+ NC GND GND Din10Din10+ GND GND Din11Din11+ GND GND Din12Din12+ GND GND NC -RESET GND GND LE -LE NC NC NC Vcc Logic LVDS In LVDS In LVDS In LVDS In LVDS In LVDS In LVDS In LVDS In LVDS In LVDS In LVDS In LVDS In LVCMOS In LVCMOS In LVCMOS In Transmitter Pin Nomenclature Vcc Power supply of laser driver Dinx+ Data channel input non-inverted DinxData channel input inverted GND Ground NC No connection LCU Laser controller Up High = nornal operation, low= laser fault or reset low RESET High = laser array is active, low = switches laser array off LE Laser enable, high active High = laser array is on if –LE is also active Low = laser array is off -LE Laser enable, low active Low = laser array is on if LE is also active. 5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A!-FIBER or 1-630-512-8787 USA/30MFO/2001.09 Web: www.molex.com 5 PRELIMINARY ParaLink-1.6G SEPTEMBER 2001 Mechanical Outline Dimensions labeling Molex - USA ParaLink 1.6 P/N 86991-xxxx S/N nnnnnnn-nnn Class 1 Laser Product case temperature measured here Isometric view Top view 13.93 12.73 13.93 3.5 3.5 End View-RX End View-TX MOLEX FIBER OPTICS DIVISION 86001-0152, rev.1.2 12.73 5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A!-FIBER or 1-630-512-8787 USA/30MFO/2001.09 Web: www.molex.com 6 PRELIMINARY SEPTEMBER 2001 ParaLink-1.6G Recommended Circuit Board Layout MOLEX FIBER OPTICS DIVISION 86001-0152, rev.1.2 5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A!-FIBER or 1-630-512-8787 USA/30MFO/2001.09 Web: www.molex.com 7 PRELIMINARY ParaLink-1.6G SEPTEMBER 2001 Packaging Information ParaLink High Speed Optical Link ParaLink Shipping Tray Labeling Part Number: 86991-0200 Mfg. Location: Downers Grove Quantity: 10 Magazine No.: MXXXXXX Molex Fiber Optics 5224 Katrine Ave. Downers Grove, IL 60515 USA UL Recognized Component xxx xxx xxx TUV and CB Scheme Certified Class 1 Laser Product - Complies with 21 CFR Subchapter J, EN 60950, EN 60825-1, EN 60825-2, UL 1950 3rd Edition, and CSA C22.2 950-95 ParaLink Shipping Tray The information contained herein is subject to change without notice. Molex does not assume any liability arising from the application or use of any product or circuit described herein nor for any infringement of patents or other rights of third parties which may result from the use of its products. No license is granted by implication or otherwise under any patent or patent rights of Molex, Incoporated. Product Limited Warranty In the event of defect in materials or workmanship, Molex will repair or replace any purchased fiber optic product free of charge for one year from the date of original shipment. This warranty is extended only to the original purchaser and only covers failures due to defects in materials or workmanship and/or failures to meet the product specifications which occur under normal use. It does not cover damage which occurs in shipment, or failures which are caused by product not supplied by Molex or failures which result from accident, misuse, abuse, neglect, mishandling, misapplication, alteration, modification, or damage that is attributable to acts God. Molex shall replace only such quantitiy of the product proved to be defective. There are no express warranties except those as listed above. Molex Incorporated, shall not be liable under any legal theory, including, but not limited to negligence or strict liability for any injury, loss or damage, direct or consequential arising out of the use of or misuse of the product. User shall determine the suitability of the product for users intended use, and the user assumes all risk and liability whatsoever in connection therewith. 2001, Molex Inc. MOLEX FIBER OPTICS DIVISION 86001-0152, rev.1.2 5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A!-FIBER or 1-630-512-8787 USA/30MFO/2001.09 Web: www.molex.com 8