Molex 86991-0200 datasheet

advertisement
PRELIMINARY
ParaLink-1.6G
SEPTEMBER 2001
Features
n Separate transmitter
and receiver modules
n Data rate up to 1.6Gbps
per channel with total
throughput 19 Gbps
n 12 Asynchronous AC
coupled channels
n Link distance up to
200m over 62.5 µm
multimode ribbon fiber
n 3.3V low power
operation
n LVDS electrical interface
Applications
n Digital optical cross
connect switches
n Add/Drop multiplexers
n Terabit routers
n 10G-VSR
n SAN switches
n Server clusters and
high performance
computers
Description
The Molex ParaLink is a high speed parallel optical link. It consists of separate 12 channel parallel
transmitter and receiver modules. The link is completed by connecting 12 fiber multi-mode ribbon cable.
The optical interface is a MT ferrule based SMC connector. The 86991-0200 & 86991-0300 series
operate up to 1.6Gbps data rate per channel.
The transmitter module consists of a 12 channel VCSEL array and parallel laser driver circuitry which
converts 12 parallel electrical data inputs to 12 parallel optical data output signals. The module is
compatible with low voltage differential signal data inputs (LVDS). The receiver module inputs 12 parallel
optical signals and converts these into 12 parallel LVDS electrical data signals through an PIN
photodetector array and receiver circuitry.
Molex ParaLink modules are fully compatible and interoperable with Infineon PAROLI modules.
Ordering Information
Molex
Part Number
86991-0200
86991-0300
Data Rate
(Gbps)
1.6 x 12
1.6 x 12
TX/RX
TX
RX
Data Voltage
Level
LVDS
LVDS
Block Diagram
LE
TRANSMITTER
x12
Data
In
-LE
x12
X12
LVDS
Input
Stage
RECEIVER
Laser Driver
x12
VCSEL
Array
Laser Control
x12
Pin
x12
Diode
Array
Amp
Gain
Amp
x12
LVDS
x12 Output
Stage
Data
Out
x12
SD1
Signal
Detect
-SD12
Vin -RESET
MOLEX FIBER OPTICS DIVISION
86001-0152, rev.1.2
LCU
ENSD
5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A!-FIBER or 1-630-512-8787
USA/30MFO/2001.09
OEN
Web: www.molex.com
1
PRELIMINARY
ParaLink-1.6G
SEPTEMBER 2001
Transmitter Specifications
Molex p/n 86991-0200
Maximum Ratings
Parameter
Supply Voltage
Data Control Input Levels
LVDS Input Differential Voltage
Operating Case Temperature
Storage Ambient Temperature
Symbol
V
V IN
|V ID|
Tcase
Tstorage
Min
-0.3
-0.5
Symbol
Vcc
Icc
W
DR
V LVCMOSOL
V LVCMOSOH
ILVCMOSI
ILVCMOSOH
ILVCMOSOL
Rin
|II|
Pout
λc
∆λ
tR
tF
JD
JR
JT
tCSK
ER
RIN
Min
3.0
Typ
Max
4.5
Vcc+0.5
2.0
80
100
Unit
V
V
V
C
C
Comments
Vcc-Vee
Typ
3.3
350
1.2
Max
3.6
450
1.6
1600
0.4
Unit
V
mA
W
Mbps
V
V
µA
mA
mA
Ω
mA
dBm
nm
nm
ps
ps
ps
ps
ps
ps
dB
dB/Hz
Comments
0
-20
Electro-optical Characteristics
Parameter
Supply Voltage
Supply Current
Power Consumption
Data Rate per Channel
LVCMOS Output Voltage Low
LVCMOS Output Voltage High
LVCMOS Output Current High/Low
LVCMOS Output Current High
LVCMOS Output Current Low
LVDS Differential Input Impedance
LVDS Input Differential Current
Average Output Power
Center Wavelength
Spectral Width (RMS)
Optical Rise Time
Optical Fall Time
Deterministic Jitter
Random Jitter (14σ)
Total Jitter
Channel to Channel Skew
Extinction Ratio
Relative Intensity Noise
Note 1
2.5
-500
500
0.5
4.0
120
5.0
-3.0
860
0.85
400
400
125
144
238
75
80
-11.0
820
6.0
-116
12 channels
Source current
Sink current
LVDS Input Stage
Max is class 1 eye safety limit
20%-80% level, measured
using gigabit ethernet filter
50% duty cycle output pattern
dynamic
Note 1: min data rate, DRmin depends on the disparity, D, of the data stream. The running disparity of a data stream is the difference of the number of
1s and 0s of that data stream. The disparity D is the maximum value of the running disparity for all possible starting points in the data stream.
Running disparity is set to zero at the starting point. Run length is the maximum number of consecutive 1s or 0s in the data stream.
For the transmitter
DR min = D(Mbps)
Timing Specifications
Parameter
-RESET on delay time
-RESET off delay time
-RESET low duration
Symbol
t1
t2
t3
Min.
Max.
100 ms
50 µs
10 µs
Vcc
3.6V
3.0V
2.0V
-RESET
0.8V
t3
Data
MOLEX FIBER OPTICS DIVISION
86001-0152, rev.1.2
data
invalid
data
valid
t1
5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A!-FIBER or 1-630-512-8787
USA/30MFO/2001.09
t2
Web: www.molex.com
2
PRELIMINARY
ParaLink-1.6G
SEPTEMBER 2001
Receiver Specifications
p/n 86991-0300
Maximum Ratings
Parameter
Supply Voltage
Data Control Input Levels
LVDS Input Differential Voltage
Operating Case Temperature
Storage Ambient Temperature
Symbol
V
V IN
|V ID|
Tcase
Tstorage
Min
-0.3
-0.5
Symbol
Vcc
Icc
W
DR
V LVDSOL
V LVDSOH
|V OD|
Vos
tR/tF
ILVDSOL
ILVDSOH
ILVCMOSI
ILVCMOSOH
ILVCMOSOL
tCSK
Pin
PSAT
PSDA
PSDD
PSDA - PSDD
A RL
Min
3.0
Typ
Max
4.5
Vcc+0.5
2.0
80
100
Unit
V
V
V
C
C
Comments
Vcc-Vee
Typ
3.3
250
0.8
Max
3.6
350
1.3
1600
Unit
V
mA
W
Mbps
mV
mV
mV
MV
ps
mV
mV
µA
mA
mA
ps
dBm
dBm
dBm
Comments
0
-20
Electro-optical Parameters
Parameter
Supply Voltage
Supply Current
Power Consumption
Data Rate per Channel
LVDS Output Low Voltage
LVDS Output High Voltage
LVDS Output Differential Voltage
LVDS Output Offset Voltage
LVDS Rise/Fall Time
LVCMOS Output Voltage Low
LVCMOS Output Voltage High
LVCMOS Output Current High/Low
LVCMOS Output Current High
LVCMOS Output Current Low
Channel to Channel Skew
Receiver Sensitivity
Receiver Saturation
Signal Detect Assert Level
Signal Detect Reassert Level
Signal Detect Hysteresis
Return Loss of Receiver
Note 1
925
1475
400
1275
400
400
250
1125
2500
-500
500
0.5
4.0
75
-18
-3
-19
-28
1.0
12
2.5
4.0
12 channels
Source current
Sink current
BER=10-12, ER = infinite
BER=10-12, ER = infinite
dB
dB
Note 1: min data rate, DRmin depends on the disparity, D, of the data stream. The running disparity of a data stream is the difference of the number of
1s and 0s of that data stream. The disparity D is the maximum value of the running disparity for all possible starting points in the data stream.
Running disparity is set to zero at the starting point. Run length is the maximum number of consecutive 1s or 0s in the data stream.
For the receiver
DR min = 8xD(Mbps)
Receiver Timing
Parameter
Signal detect deassert
Signal detect assert
LVDS Output enable
off delay time
LVDS Output enable
on time
Symbol
t1
t2
t3
Min.
10 µs
10 µs
20 ns
t4
20 ns
Max.
Data Out
1, 12
t2
t1
Signal Detect 1
Signal Detect 12
Output
Enable
2.0V
0.8V
Data Out
t3
MOLEX FIBER OPTICS DIVISION
86001-0152, rev.1.2
5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A!-FIBER or 1-630-512-8787
USA/30MFO/2001.09
t4
Web: www.molex.com
3
PRELIMINARY
SEPTEMBER 2001
ParaLink-1.6G
Laser Safety
This optoelectronic transmitter is a Class 1 Laser Product that complies with 21 CFR Subchapter J.
According to classification methods specified in IEC 60825-1, Amendment 2, the product has an IEC
laser classification of 1M.
The transmitter contains a VCSEL laser diode array which emits laser radiation in the range of 820 to 860
nm. Light from the laser diode is attenuated so that the optoelectronic transmitter conforms to the Class 1
limit. To avoid possible exposure to laser radiation, do not open or alter the sealed housing of the
product.
No maintenance or service of the product may be performed.
Caution: The use of optical instruments with this product will increase eye hazard.
Invisible Laser Radiation. Do not stare into beam or view directly with optical instruments.
To ensure laser safety for all input data patterns, each channel is controlled internally and will be switched
off if laser safety limits are exceeded. A channel alerter switches the respective data channel output off if
the input duty cycle permanently exceeds 57%. The alerter will not disable the channel below an input
duty cycle of 57% under all circumstances. The minimum alerter response time is 1 us with a constant
high input. This means in the input data bit stream, ones (1s) in excess of a 57% duty cycle, consecutive
or non-consecutive, the time interval of excessive high input must not exceed 1 us, otherwise the
respective channel will be switched off. The alterter switches the respective channel from off to on
without the need of resetting the module.
All of the channel alerters operate independently. This means an alert within a channel does not affect
the other channels. To decrease the power consumption of the module, the unused channel inputs can
be tied to high input level. This allows a portion of the supply current in this channel to be shut down by
the corresponding alerter.
On the transmitter module pin #67 and #68, laser enable high and laser enable low, can be used to as an
input for connection with an Open Fiber Control (OFC) circuit to configure an IEC Class 1 link.
MOLEX FIBER OPTICS DIVISION
86001-0152, rev.1.2
5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A!-FIBER or 1-630-512-8787
USA/30MFO/2001.09
Web: www.molex.com
4
PRELIMINARY
ParaLink-1.6G
SEPTEMBER 2001
Pin Out Description
Pin
Numbering
System
1.6Gbps Receiver, p/n 86991-0300
Pin#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
Name
GND
Vcc
Vcc
NC
OEN
SD1
Vcco
GND
NC
GND
GND
GND
Dout1+
Dout1GND
GND
Dout2+
Dout2GND
GND
Dout3+
Dout3GND
GND
NC
Dout4+
Dout4GND
Dout5+
Dout5GND
GND
Dout6+
Dout6GND
GND
Logic
LVCMOS In
LVCMOS Out
LVDS Out
LVDS Out
LVDS Out
LVDS Out
LVDS Out
LVDS Out
LVDS Out
LVDS Out
LVDS Out
LVDS Out
LVDS Out
LVDS Out
Pin#
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
Name
Dout7Dout7+
GND
GND
Dout8+
Dout8GND
GND
GND
Dout9+
Dout9NC
GND
GND
Dout10+
Dout10GND
GND
Dout11+
Dout11GND
GND
Dout12+
Dout12GND
GND
GND
NC
GND
Vcoo
-SD12
ENSD
NC
Vcc
Vcc
GND
86001-0152, rev.1.2
Pin#
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
LVDS Out
LVDS Out
LVDS Out
LVDS Out
LVDS Out
LVDS Out
LVDS Out
LVDS Out
LVDS Out
LVDS Out
LVCMOS Out
LVCMOS In
Receiver Pin Nomenclature
Vcc
Power supply of pre-amp and analog circuitry
Vcoo
Power supply of output stage
Doutx+
Data channel output non-inverted
DoutxData channel ouotput inverted
GND
Ground
NC
No connection
OEN
Output enable, high=normal operation
Low = sets all data outputs
ENSD
High = SD1 and SD12 function enabled
Low = SD1 and SD12 permanent active
SD1
signal detect on fiber 1
High = signal of sufficient AC power on fiber 1
Low = signal on fiber 1 is insufficient
SD12
Signal detect on fiber 12
High = signal of sufficient AC power on fiber 12
Low = signal on fiber 12 is insufficient.
MOLEX FIBER OPTICS DIVISION
1.6Gbps Transmitter, p/n 86991-0200
Logic
LVDS Out
LVDS Out
Name
Vcc
NC
NC
NC
NC
LCU
GND
GND
NC
NC
GND
GND
Din1Din1+
GND
GND
Din2Din2+
GND
GND
Din3Din3+
GND
GND
NC
Din4Din4+
GND
Din5Din5+
GND
GND
Din6Din6+
GND
GND
Logic
LVCMOS Out
LVDS In
LVDS In
LVDS In
LVDS In
LVDS In
LVDS In
LVDS In
LVDS In
LVDS In
LVDS In
LVDS In
LVDS In
Pin#
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
Name
Din7Din7+
GND
GND
Din8Din8+
GND
GND
GND
Din9Din9+
NC
GND
GND
Din10Din10+
GND
GND
Din11Din11+
GND
GND
Din12Din12+
GND
GND
NC
-RESET
GND
GND
LE
-LE
NC
NC
NC
Vcc
Logic
LVDS In
LVDS In
LVDS In
LVDS In
LVDS In
LVDS In
LVDS In
LVDS In
LVDS In
LVDS In
LVDS In
LVDS In
LVCMOS In
LVCMOS In
LVCMOS In
Transmitter Pin Nomenclature
Vcc
Power supply of laser driver
Dinx+
Data channel input non-inverted
DinxData channel input inverted
GND
Ground
NC
No connection
LCU
Laser controller Up
High = nornal operation, low= laser fault or reset low
RESET
High = laser array is active, low = switches laser array off
LE
Laser enable, high active
High = laser array is on if –LE is also active
Low = laser array is off
-LE
Laser enable, low active
Low = laser array is on if LE is also active.
5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A!-FIBER or 1-630-512-8787
USA/30MFO/2001.09
Web: www.molex.com
5
PRELIMINARY
ParaLink-1.6G
SEPTEMBER 2001
Mechanical Outline Dimensions
labeling
Molex - USA
ParaLink 1.6
P/N 86991-xxxx
S/N nnnnnnn-nnn
Class 1 Laser Product
case temperature
measured here
Isometric view
Top view
13.93
12.73
13.93
3.5
3.5
End View-RX
End View-TX
MOLEX FIBER OPTICS DIVISION
86001-0152, rev.1.2
12.73
5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A!-FIBER or 1-630-512-8787
USA/30MFO/2001.09
Web: www.molex.com
6
PRELIMINARY
SEPTEMBER 2001
ParaLink-1.6G
Recommended Circuit Board Layout
MOLEX FIBER OPTICS DIVISION
86001-0152, rev.1.2
5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A!-FIBER or 1-630-512-8787
USA/30MFO/2001.09
Web: www.molex.com
7
PRELIMINARY
ParaLink-1.6G
SEPTEMBER 2001
Packaging Information
ParaLink High Speed Optical Link
ParaLink Shipping
Tray Labeling
Part Number:
86991-0200
Mfg. Location: Downers Grove
Quantity:
10
Magazine No.: MXXXXXX
Molex Fiber Optics
5224 Katrine Ave.
Downers Grove, IL
60515 USA
UL Recognized Component
xxx
xxx
xxx
TUV
and
CB
Scheme
Certified
Class 1 Laser Product - Complies with 21 CFR Subchapter J,
EN 60950, EN 60825-1, EN 60825-2, UL 1950 3rd Edition, and CSA C22.2 950-95
ParaLink Shipping Tray
The information contained herein is subject to change without notice. Molex does not assume any liability arising from the
application or use of any product or circuit described herein nor for any infringement of patents or other rights of third parties which
may result from the use of its products. No license is granted by implication or otherwise under any patent or patent rights of Molex,
Incoporated.
Product Limited Warranty
In the event of defect in materials or workmanship, Molex will repair or replace any purchased fiber optic product free of charge for
one year from the date of original shipment. This warranty is extended only to the original purchaser and only covers failures due to
defects in materials or workmanship and/or failures to meet the product specifications which occur under normal use. It does not
cover damage which occurs in shipment, or failures which are caused by product not supplied by Molex or failures which result from
accident, misuse, abuse, neglect, mishandling, misapplication, alteration, modification, or damage that is attributable to acts God.
Molex shall replace only such quantitiy of the product proved to be defective.
There are no express warranties except those as listed above. Molex Incorporated, shall not be liable under any legal theory,
including, but not limited to negligence or strict liability for any injury, loss or damage, direct or consequential arising out of the use of
or misuse of the product. User shall determine the suitability of the product for users intended use, and the user assumes all risk
and liability whatsoever in connection therewith.
 2001, Molex Inc.
MOLEX FIBER OPTICS DIVISION
86001-0152, rev.1.2
5224 Katrine Avenue, Downers Grove, IL 60515 / Tel: 800-A!-FIBER or 1-630-512-8787
USA/30MFO/2001.09
Web: www.molex.com
8