TOF/Spot Technical data Optical Connection cable and electrical connection Standard version Operating range - P, C, T and A types - N type Active light spot at 2 m distance Offset - C and T types Measurement precision Max. ambient light 0.2 ... 6 m 0.2 ... 3 m 40 mm × 40 mm 0.15 m ±5% at 2 m ±10 cm over the whole range 100,000 Lux Mechanical Dimensions Housing material Housing color Enclosure rating Temperature range Relative humidity (non-condensing) Electrical Supply voltage USP Current consumption at 24 VDC Peak current consumption during power up at 24 VDC Output Max. switching voltage Max. switching current Max. power-up time Max. response time Test response time Ø 29.5 mm × 35.8 mm Polycarbonate Black IP65 −40 °C ... +60 °C 0 ... 95 % Length 2m Diameter Ø 3.4 mm Material PVC, black WiresAWG26 • brown +USP • black Output A / Analog output • green Output B / Analog GND • blue GND (0 V) / −USP • white Test input • gray Logic selector General EMC emission EN 61000-6-3:2007 EMC immunity EN 61000-6-2:2005 Vibration EN 60068-2-6:2007 Shock EN 60068-2-27:2008 RoHS2011/65/EU CertificateCE 10 ... 30 VDC / 12 ... 24 VAC 50 mA 500 mA Solid-state relay, analog 60 V 150 mA 1s 60 ms 5 ms P = Preset, C = Automatic calibration, N = Potentiometer, A = Analog, T = Teach-in button Features Time-of-Flight (TOF) sensor Exact distance setting, independent from background Excellent detection capability Solid-state relay and analog output Small and sleek design Operating range from 0.2 m up to 6 m Easy mounting Insensitive to ambient light up to 100,000 Lux CEDES AG reserves the right to modify or change technical data without prior notice. RoHS CEDES AG is certified according to ISO 9001: 2008 TOF/Spot Output A black Output A black Output B green Output B green GND (0 V) blue Test input* white Logic selector grayB Output A = Output n.c. = not connected and isolated n.c. white n.c. gray Output A = Output B n.c. = not connected and isolated Dimensions Analog output (DC supply) brown Analog output (4 ... 20 mA) black Analog GND green GND (0 V) blue Test input* white n.c. gray Ø 34 35.8 USP (10 ... 30 VDC) blue ∼Vcc (12 ... 24 VAC) Output A = Output B * = If test input not used - connect with U SP or GND TOF/Spot brown ∼Vcc (12 ... 24 VAC) Controller AC supply brown - Universal Ø 29.5 * = If test input not used - connect with U SP or GND n.c. = not connected and isolated All dimensions in mm Output description Solid state relay output Analog output Current [mA] Output A and B NC (normally closed) Logic selector connected to GND (0 V) or not connected NO (normally open) Logic selector connected to USP Contact closed 20 Contact open Contact closed Contact open 4 0.2 6.0 Distance [m] Application examples Elevator doors Swing doors CEDES AG, Science Park | CH-7302 Landquart | Phone: +41 81 307 2323 | Fax: +41 81 307 2325 | info.eu@cedes.com | www.cedes.com Bus doors 001 206 en | 141208 | V 2.2 and isolated used - connect D USP (10 ... 30 VDC) Controller TOF/Spot and isolated used - connect D og output Solid state relay output (AC supply) Solid state relay output (DC supply) Controller ersal Output connections