:FNJCC998i [b[Yjh_YWbY^WhWYj[h_ij_Yi DEVICES DPX 125 DPX-E 16 kA Type of MCCB DPX 25 kA DPX 160 DPX 36 kA Number of poles 1P 3P - 3P + N/2 - 4P Nominal rating (A) 16 125 16 - 125 DPX 25 kA DPX 250 ER DPX 36 kA DPX 50 kA DPX 25 kA 3P - 3P + N/2 - 4P 63 - 160 63 - 160 40 - 160 DPX 36 kA DPX 250 Electronic release DPX 250 DPX 50 kA DPX 36 kA DPX-H 70 kA DPX 36 kA DPX-H 70 kA 3P - 3P + N/2 - 4P 3P - 3P + N/2 - 4P 3P - 4P 100 - 250 40 - 250 40 - 250 DPX 630 Electronic release DPX 630 DPX 36 kA DPX-H 70 kA DPX 36 kA 3P - 4P DPX-H 70 kA DPX 36 kA 3P - 3P + N/2 - 4P 250 - 630 320 - 630 250 - 630 400 - 630 DPX 1600 Electronic release DPX 1250 DPX-H 70 kA DPX 50 kA DPX-H 70 kA 3P - 4P 3P - 4P 800 - 1250 800 - 1600 Breaking capacity (kA) (EN 60947-2 and IEC 60947-2) 400 V± - 16 25 36 25 36 50 25 36 50 36 70 36 70 36 70 36 70 50 70 50 70 230 V± 16 22 35 40 40 50 65 40 50 65 60 100 60 100 60 100 60 100 80 100 80 100 Breaking capacity Ics (% Icu) 50 100 50 75 100 75 50 100 75 50 100 75 100 75 100 75 100 75 100 75 100 75 Characteristics of use Nominal frequency Maximum rated operating voltage Ue (V) 50/60 Hz 230 V± 500 V± - 250 V= 50/60 Hz 500 V± - 250 V= 500 V± - 250 V= 690 V± - 250 V= 690 V± 690 V± - 250 V= 690 V± 690 V± - 250 V= 690 V± A B A A A A A A A: In 630 A B: In 200 to 400 A Thermal 0.7 to 1 In 0.64 to 1 In 0.64 to 1 In 0.64 to 1 In - 0.8 to 1 In - 0.8 to 1 In - Magnetic fixed fixed fixed 3.5 to 10 In - 5 to 10 In - 5 to 10 In - - - - - Ir : 0.4 to 1 In - Ir : 0.4 to 1 In - Ir : 0.4 to 1 In - - - - Im: 1.5 / 10 Ir - Im: 1.5 / 10 Ir - Im: 1.5 / 10 Ir - Ir : 0.4 to 1 In Tr : 5 to 30 s - Ir : 0.4 to 1 In Tr : 5 to 30 s Category of use Thermal-magnetic adjustment Electronic protection adjustment S1 - - - - Ir : 0.4 to 1 In Tr : 5 to 30 s - - - - Im: 1.5 / 10 Ir Tm: 0.01 to 0.3 s - Im: 1.5 / 10 Ir Tm: 0.01 to 0.3 s - Im: 1.5 / 10 In Tm: 0.01 to 0.3 s Rigid cable 70 mm2 95 mm2 185 mm2 185 mm2 185 mm2 300 mm2 or 2 x 240 mm2 300 mm2 or 2 x 240 mm2 2 or 4 x 240 mm2 2 or 4 x 240 mm2 Flexible cable 50 mm2 70 mm2 150 mm2 150 mm2 150 mm2 240 mm2 or 2 x 185 mm2 240 mm2 or 2 x 185 mm2 2 or 4 x 185 mm2 2 or 4 x 185 mm2 Copper bar and lug width 12 mm(1) 18 mm(1) 22 mm(1) 25 mm 25 mm 32 mm 32 mm 50 mm 50 mm 6 Nm 10 Nm 10 Nm 15 Nm 15 Nm 15 Nm 15 Nm 20 Nm 20 Nm S2 Maximum cable cross-section Tightening torque Nominal current (In) at 40°C (A) In (A) 16 25 40 63 100 125 40 63 100 160 40 160 250 40 63 100 160 250 Phase 16 25 40 63 100 125 40 63 100 160 40 160 250 40 63 100 160 250 N 16 25 40 63 100 125 40 63 100 160 40 160 250 40 63 100 160 250 - - - - - 63 - - - 100 - - - 40 63 63 100 160 N/2 Magnetic threshold (Im) (A)(2) 40 100 160 250 250 40 100 160 250 250 0 - 50 - 100 % of phase value 320 400 630 320 400 500 630 320 400 500 630 250 250 250 320 Fixed 250 400 630 800 1000 1250 250 400 630 800 1000 1250 800 1000 1250 500 500 630 0 - 50 - 100 % of phase value 16 25 40 63 125 40 63 100 160 100 160 250 63 100 160 250 250 400 630 800 1000 1250 Phase 480 625 800 950 1250 1250 400 630 1000 1600 1000 1600 2500 220 630 350 1000 560 1600 900 2500 1250 2500 2000 4000 3150 6300 4000 8000 5000 10000 6250 12500 2500 220 630 350 1000 560 1600 900 2500 1250 2500 2000 4000 3150 6300 4000 8000 5000 10000 6250 12500 1600 220 630 220 630 350 1000 560 1600 800 1600 1250 2500 2000 4000 N/2 480 625 800 950 1250 1250 950 400 630 800 1250 1600 800 1250 1600 0 - 50 - 100 % of phase value Adjustable In (A) N 100 500 1000 1600 1000 1000 1600 1: Copper bar only 2: Trip current for 50/60 Hz. For direct current, multiply by 1.5 130 131 www.klinkmann.com www :FNJC'(+ j^[hcWbcW]d[j_YC998i\hec',je'(+7 0 250 18 0 250 59 0 262 01 0 250 45 + 0 260 13 Dimensions see e-catalogue Electrical characteristics p. 130 MCCBs for switching, control isolation and protection of low voltage electrical lines Can be fitted with auxiliaries (p. 144) Can be used with earth leakage modules or with residual current relays (p. 145) Supplied complete with: - cage terminals 70 mm2 max. - terminal shields Thermal release adjustable from 0.7 to 1 In and sealable Fixed magnetic at 10 In in factory (p. 146) Conform to IEC 60947-2 Can be mounted on rail 2 or on plate in XL3 cabinets and enclosures Pack DPX-E 125 - fixed version Cat.Nos 1P 0 250 00 0 250 01 0 250 02 0 250 03 0 250 04 0 250 05 0 250 06 0 250 07 0 250 08 0 250 09 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3P 4P 0 250 16 0 250 17 0 250 18 0 250 19 0 250 20 0 250 21 0 250 24 0 250 25 0 250 26 0 250 27 0 250 28 0 250 29 3P + N/2 0 250 23 1 Pack Breaking capacity Icu 16 kA (230 V±) In 16 A 20 A 25 A 32 A 40 A 50 A 63 A 80 A 100 A 125 A Breaking capacity Icu 16 kA (400 V±) In 16 A 25 A 40 A 63 A 100 A 125 A In 125 A Electronic earth leakage modules Cat.Nos 3P 4P 1 1 0 260 02 0 260 03 0 260 12 0 260 13 1 1 0 260 04 0 260 14 Rotary handles 1 1 0 262 01 0 262 03 1 1 0 262 75 0 262 76 1 1 1 1 0 262 92 0 262 93 0 262 94 0 262 25 DPX 125 - fixed version 1 1 1 1 1 1 3P 4P 0 250 36 0 250 37 0 250 38 0 250 39 0 250 40 0 250 41 0 250 44 0 250 45 0 250 46 0 250 47 0 250 48 0 250 49 3P + N/2 0 250 43 1 3P 1 1 1 1 1 1 4P 0 250 50 0 250 51 0 250 52 0 250 53 0 250 54 0 250 55 0 250 58 0 250 59 0 250 60 0 250 61 0 250 62 0 250 63 3P + N/2 1 0 250 57 Breaking capacity Icu 25 kA (400 V±) In 16 A 25 A 40 A 63 A 100 A 125 A In 125 A Breaking capacity Icu 36 kA (400 V±) In 16 A 25 A 40 A 63 A 100 A 125 A In 125 A Can be fitted onto DPX/DPX-I 125 Adjustable, sealable sensitivity: 0.03 - 0.3 - 1 - 3 A Adjustable, tripping: 0 - 0.3 - 1 - 3 s Test push-button Reset push-button Remote earth fault signalling contact Switch for mechanical tests (installation insulation test) 230-500 V± Mounted side by side (at right-hand side) In 63 A 125 A Mounted underneath 63 A 125 A Direct on DPX Standard (grey) For emergency use (red/yellow) Vari-depth handle IP 55 Comprising: connection rod, bracket, drilling template, fixing accessories, door lock mechanism Standard (grey) For emergency use (red/yellow) Locking accessories Eurolocks for vari-depth handle Profalux for vari-depth handle Ronis for vari-depth handle Eurolocks for direct handle Accessories Sealable terminal shields 0 262 05 0 262 06 Set of 2 Rear terminals Used to connect fixed version with front terminals into fixed version with rear terminal 0 263 00 0 263 01 Set of upstream or downstream rear terminals 3P 1 1 132 www.klinkmann.com www 4P :FNJC',& j^[hcWbcW]d[j_YC998i\hec*&je',&7 0 251 25 0 251 33 + 0 260 21 Mounting accessories and common accessories p. 135 0 262 11 Dimensions see e-catalogue Electrical characteristics p. 130 MCCBs for switching, control isolation and protection of low voltage electrical lines Can be fitted with auxiliaries (p. 144) Can be used with earth leakage modules or with residual current relays (p. 145) Supplied complete with: - connection plates for bars - upstream and downstream connection devices for lugs (max. width 20 mm) - terminal shields Conform to IEC 60947-2 Can be mounted on rail 2 or on plate in XL3 cabinets and enclosures Pack 3P 1 1 1 Fixed version Cat.Nos 4P 0 251 23 0 251 31 0 251 24 0 251 32 0 251 25 0 251 33 3P + N/2 0 251 27 1 3P 4P 1 1 1 0 251 49 0 251 57 0 251 50 0 251 58 0 251 51 0 251 59 1 0 251 53 3P + N/2 1 1 1 1 3P 4P 0 251 62 0 251 63 0 251 64 0 251 65 0 251 70 0 251 71 0 251 72 0 251 73 3P + N/2 1 0 251 67 Thermal adjustable from 0.64 to 1 In and sealable Fixed magnetic at 10 In in factory (p. 146) Breaking capacity Icu 25 kA (400 V±) In 63 A 100 A 160 A In 160 A Breaking capacity Icu 36 kA (400 V±) In 63 A 100 A 160 A In 160 A Breaking capacity Icu 50 kA (400 V±) In 40 A 63 A 100 A 160 A In 160 A Supply invertor type 1 0 264 01 1 Cat.Nos 1 1 0 262 11 0 262 13 1 1 0 262 77 0 262 78 1 1 1 1 0 262 92 0 262 93 0 262 94 0 262 25 Rotary handles Direct on DPX Standard (grey) For emergency use (red/yellow) Vari-depth handle IP 55 Comprising: connecting rod, bracket, drilling template, fixing accessories, door lock mechanism Standard (grey) For emergency use (red/yellow) Locking accessories Eurolocks for vari-depth handle Profalux for vari-depth handle Ronis for vari-depth handle Eurolocks for direct handle Accessories 1 1 1 1 Mounting plate For mechanical interlocking of 2 DPX of the same size for use in normal or automatic modes Electronic earth leakage modules 1 Pack 1 Can be fitted onto DPX/DPX-I 160 Adjustable, sealable sensitivity: 0.03 - 0.3 - 1 - 3 A Adjustable, tripping: 0 - 0.3 - 1 - 3 s Test push-button Reset push-button Remote earth fault signalling contact Switch for mechanical tests (installation insulation test) 230-500 V± 3P 4P Mounted side by side (at right-hand side) 0 260 20 0 260 21 160 A Mounted underneath 0 260 22 160 A Sealable terminal shields 3P 4P 0 262 15 0 262 16 Set of 2 Cage terminals Set of 4 0 262 18 For cable without lug 95 mm2 (rigid) or 70 mm2 (flexible) 0 262 19 For cable without lug 120 mm2 (rigid) or 95 mm2 (flexible) Adaptator for lug 0 262 17 Set of 4 (upstream or downstream) Supplied with insulated shield Rear terminals Used to connect a fixed version with front terminals into fixed version with 3P 4P rear terminals 0 263 10 0 263 11 Set of upstream and downstream rear terminals 133 www.klinkmann.com www :FNJC(+&;H j^[hcWbcW]d[j_YC998i\hec'&&je(+&7 0 252 55 Protective cover for Cat.No 0 265 13 0 252 56 + 0 260 36 0 265 17 0 262 11 Dimensions see e-catalogue Electrical characteristics p. 130 MCCBs for switching, control isolation and protection of low voltage electrical lines Can be fitted with auxiliaries (p. 144) Can be used with earth leakage modules or with residual current relays (p. 145) Supplied complete with: - connection plates for bars - upstream and downstream connection devices for lugs (max. width 20 mm) - terminal shields Can be mounted on rail 2 or on plate in XL3 cabinets and enclosures Conform to IEC 60947-2 Pack Fixed version Cat.Nos 3P 4P 1 1 1 0 252 04 0 252 14 0 252 05 0 252 15 0 252 06 0 252 16 1 0 252 09 1 1 1 0 252 24 0 252 34 0 252 25 0 252 35 0 252 26 0 252 36 1 0 252 29 3P + N/2 3P 4P 3P + N/2 3P 4P 1 1 1 0 252 44 0 252 54 0 252 45 0 252 55 0 252 46 0 252 56 1 0 252 49 3P + N/2 Pack Thermal adjustable from 0.64 to 1 In and sealable Fixed magnetic at 10 In in factory (p. 146) Breaking capacity Icu 25 kA (400 V±) In 100 A 160 A 250 A In 250 A Breaking capacity Icu 36 kA (400 V±) In 100 A 160 A 250 A In 250 A Breaking capacity Icu 50 kA (400 V±) In 100 A 160 A 250 A In 250 A Plug-in version 1 1 1 1 A plug-in is a DPX fitted with tulip contacts mounted on a base 3P 4P Tulip contacts 0 265 12 0 265 13 Set of tulip contacts (supplied with an incoming/outgoing protective cover) Bases Can accept DPX and DPX-I fitted with tulip contacts For DPX only 0 265 14 0 265 15 Front terminal mounting base 0 265 16 0 265 17 Rear terminal mounting base Connectors For connecting the auxiliaries included in the DPX 0 263 99 Set of connectors (8-pin) 4P 1 1 0 260 31 0 260 36 1 0 260 33 0 260 38 1 1 0 264 02 Can be fitted onto DPX/DPX-I 250 ER Adjustable, sealable sensitivity: 0.03 - 0.3 - 1 - 3 A Adjustable, tripping: 0.03 - 0.3 - 1 - 3 s Test push-button Reset push-button Remote earth fault signalling contact Switch for mechanical tests (installation insulation test) Mounted side by side (at right-hand side) 160 A 250 A Mounted underneath 160 A 250 A Rotary handles 1 1 0 262 11 0 262 13 1 1 0 262 77 0 262 78 1 1 1 1 0 262 92 0 262 93 0 262 94 0 262 25 Direct on DPX Standard (grey) For emergency use (red/yellow) Vari-depth handle IP 55 Comprising: connecting rod, bracket, drilling template, fixing accessories, door lock mechanism Standard (grey) For emergency use (red/yellow) Locking accessories Eurolocks for vari-depth handle Profalux for vari-depth handle Ronis for vari-depth handle Eurolocks for direct handle Accessories Sealable terminal shields 0 262 85 0 262 86 Set of 2 Cage terminals 0 262 881 Set of 4 For cable without lug 185 mm2 (rigid) or 150 mm2 (flexible) for DPX 250 ER and DPX-IS 250 3P 4P Spreaders 0 262 90 0 262 91 Set of incoming or outgoing spreaders Rear terminals Used to convert the fixed version with front terminals to the fixed version with rear terminals 0 265 10 0 265 11 Set of upstream and downstream rear terminals 3P 1 1 1 Supply invertor type Mounting plate For mechanical interlocking of 2 DPX of the same size for use in normal or automatic modes Electronic earth leakage modules Cat.Nos 1 134 www.klinkmann.com www 4P 1 : Can not be mounted on side by side mounted earth leakage modules 160 A :FNJC'(+"',&WdZ(+&;H :FNJC'(+"',&WdZ(+&;H cekdj_d]WYY[iieh_[i Yedd[Yj_ed ■ Connection DPX front terminals Connection with cables Connection with bars D Ø 0 262 08 0 048 67 0 048 68 0 262 00 6 Nm Pack 1 1 Cat.Nos For fixing devices on rail 0 262 08 For DPX 125 or downstream earth leakage module 0 262 09 For DPX 160, DPX 250 ER or downstream earth leakage module DPX 125 160 250 ER max. Ø 12 18 18 Plug-in version (only DPX 250 ER) Front terminals Insulated shields 1 6 Nm Fixing plates Insulated shields Used to isolated the connection between each pole 0 262 07 Set of 3 DPX 125 160 250 ER D 12 18 18 Rear terminals Distribution terminals 1 1 0 048 67 160 A - 6 outputs 25 mm2 flexible - Isc peak 30 k Can be fitted directly onto downstream terminal of DPX 165/160, Vistop 100/160 A and DX H 125 A 0 048 68 250 A - 4 outputs 35 mm2 flexible and 2 outputs 25 mm2 flexible- Isc peak 36 k Can be fitted directly onto downstream terminal of DPX 250/250 ER and DX-IS 250 Padlocks 1 1 For locking in "off" position 0 262 00 For DPX 125 0 262 10 For DPX 160 and DPX 250 ER ■ Mounting of distribution terminal 135 www.klinkmann.com www :FNJC(+& j^[hcWbcW]d[j_YWdZ[b[Yjhed_Yh[b[Wi[C998i\hec*&je(+&7 0 253 49 0 253 52 0 254 23 DPX Auxiliaries p. 144 Dimensions see e-catalogue Electrical characteristics p. 130 Moulded case MCCBs for switching, control isolation and protection of low voltage electrical lines Can be fitted with auxiliaries (p. 144) Can be used with earth leakage modules (opposite) or with residual current relays (p. 145) Supplied complete with: - connection plates for bars - upstream and downstream connection devices for lugs (width max. 20 mm) - terminal shields Conform to IEC 60947-2 Sealable adjustment Can be mounted on plate in XL3 cabinets and enclosures Pack DPX 250 thermal magnetic Cat.Nos Pack DPX 250 electronic release S1 Cat.Nos Thermal adjustable from 0.64 to 1 In Magnetic adjustable from 3.5 to 10 In Adjustment of Ir and Im (p. 146) Instantaneous protection If = 4 kA Indicator lamp Minimum current for indicator lamp operation (30 % of In) - green: normal fixed red: I ≥ 0.9 Ir - flushing red: I ≥ 1.05 Ir Connector for test unit Dynamic selectivity 4P version: adjustment of neutral on front panel t Ir Ii I DPX 250 36 kA Breaking capacity Icu 36 kA (400 V±) 1 1 1 1 1 3P 4P 0 253 28 0 253 29 0 253 30 0 253 31 0 253 32 0 253 45 0 253 46 0 253 47 0 253 48 0 253 49 3P + N/2 1 1 1 1 1 1 1 3P 4P 0 253 52 0 253 53 0 253 54 0 253 55 0 253 56 0 253 69 0 253 70 0 253 71 0 253 72 0 253 73 0 253 66 Ir In 40 A 63 A 100 A 160 A 250 A Ii 160 A 250 A DPX-H 250 70 kA Breaking capacity Icu 70 kA (400 V±) 3P 4P 1 1 1 1 0 254 01 0 254 03 0 254 04 0 254 05 0 254 07 0 254 09 0 254 10 0 254 11 1 1 1 1 0 254 13 0 254 15 0 254 16 0 254 17 0 254 19 0 254 21 0 254 22 0 254 23 In 40 A 63 A 100 A 160 A 250 A In If I DPX 250 36 kA Breaking capacity Icu 36 kA (400 V±) In 0 253 41 0 253 42 3P + N/2 1 t In 40 A 100 A 160 A 250 A DPX-H 250 70 kA Breaking capacity Icu 70 kA (400 V±) In 250 A 136 www.klinkmann.com www 40 A 100 A 160 A 250 A :FNJC(+& j^[hcWbcW]d[j_YWdZ[b[Yjhed_Yh[b[Wi[C998i\hec*&je(+&7Yedj_dk[Z 0 260 55 0 265 32 0 260 53 Pack DPX 250 electronic release S2 Cat.Nos Pack Adjustment of Ir, Im, Tr, Tm (p. 146) Instantaneous protection If = 4 kA Indicator lamp Minimum current for indicator lamp operation (30 % of In) - green: normal fixed red: I ≥ 0.9 Ir - flushing red: I ≥ 1.05 Ir Connector for test unit Dynamic selectivity 4P version: adjustment of neutral on front panel t 0 265 46 Ir Tr 3P 0 265 29 0 265 30 1 1 0 265 31 0 265 32 0 265 33 0 265 34 1 0 265 35 0 265 36 1 1 0 265 37 0 265 38 1 0 265 39 1 1 1 0 263 99 0 098 19 0 263 43 4P Tsd I2t I DPX 250 36 kA Breaking capacity Icu 36 kA (400 V±) 1 1 1 1 4P 0 254 40 0 254 41 0 254 42 0 254 43 0 254 45 0 254 46 0 254 47 0 254 48 In 40 A 100 A 160 A 250 A DPX-H 250 70 kA Breaking capacity Icu 70 kA (400 V±) 0 254 50 0 254 51 0 254 52 0 254 53 0 254 55 0 254 56 0 254 57 0 254 58 3P 1 1 4P 1 1 40 A 100 A 160 A 250 A Electronic earth leakage modules 1 1 Can be fitted onto DPX/DPX-I 250 Adjustable, sealable sensitivity: 0.03 - 0.3 - 1 - 3 A Adjustable, time delay: 0 - 0.3 - 1 - 3 s Test push-buttons Reset push-button Remote earth fault signalling contact Switch for mechanical tests (installation insulation test) Mounted underneath Standard 1 1 0 260 53 0 260 57 1 1 A DPX draw-out version is a plug-in DPX fitted with a "Debro-lift" mechanism which can be used to withdraw the DPX while keeping it on its base "Debro-lift" mechanism Supplied with a rigid slide and handle for 3P 4P drawing-out 0 265 45 0 265 46 For DPX base only 0 265 47 For DPX base with earth leakage module Key lock for "Debro-lift" mechanism Enable locking of DPX in drawn-out position 0 265 76 One key Ronis for DPX only 0 265 78 One key Ronis for motorised DPX or with rotary handle Accessories for "Debro-lift" mechanism 0 265 75 Isolated handle for drawing-out 0 265 74 Signalling contact (plugged-in/drawn-out) In 0 260 51 160 A 0 260 54 0 260 55 250 A LED version Monitors the isolation state of the installation via a series of LEDs 4P A plug-in is a DPX fitted with tulip contacts mounted on a base Tulip contacts Set of tulip contacts (supplied with an incoming/outgoing protective cover) Bases for DPX only Accept DPX/DPX-I fitted with tulip contacts Front terminal mounting base Rear terminal mounting base with threaded rod Flat rear terminal mounting base Bases for DPX with earth leakage module Front terminal mounting base Rear terminal mounting base with threaded rod Flat rear terminal mounting base Accessories Set of connectors (8-pin) Set of connectors (6-pin) Set of 2 extractor handle Draw-out version In 1 1 1 1 4P 1 Isd 3P Plug-in version Cat.Nos Supply invertor type 1 0 264 08 1 0 264 03 In 160 A 250 A A supply invertor type is composed of one plate with interlock for 2 devices Plate for MCCB or trip-free switch fixed version Plate for MCCB or trip-free switch plug-in and draw-out version For DPX-L 100 kA and Sg electronic release version, please consult us 137 www.klinkmann.com www :FNJC(+& [gk_fc[djWdZWYY[iieh_[i 0 262 22 Pack 1 1 1 1 1 1 1 1 0 262 79 Cat.Nos Rotary handles Direct on DPX 0 262 22 Standard (grey) 0 262 24 For emergency use (red/yellow) - can be fitted on Cat.Nos 0 262 22, 0 262 41 or 0 262 81 Vari-depth handle IP 55 Comprising: connection rod, bracket, self-adhesive drilling template, mounting accessories and door lock mechanism 0 262 79 Standard (black) 0 262 80 Conversion kit for emergency use Can be fitted on Cat.No 0 262 79 Locking accessories 0 262 92 Eurolocks for vari-depth handle 0 262 93 Profalux for vari-depth handle 0 262 94 Ronis for vari-depth handle 0 262 25 Eurolocks for direct handle Motor-driven handles 1 1 1 1 0 262 80 Front operated 0 261 30 24 V±/= 0 261 34 230 V± Accessories 0 261 59 Ronis locking accessory 0 261 58 Profalux locking accessory 0 261 30 Accessories Pack Cat.Nos 1 0 262 30 1 1 0 262 26 0 262 27 0 262 28 0 262 29 1 0 262 21 1 0 262 35 1 0 262 31 3P 4P 0 262 32 1 3P 4P 1 0 262 33 0 262 34 1 0 263 31 0 263 32 1 0 265 27 0 265 28 1 0 048 68 138 www.klinkmann.com www Insulated shields Set of 3 Sealable terminal shields Set of 2 long terminal shields Set of 2 short terminal shields Padlock For locking in "open" position Cage terminals Set of 4 terminals for cable 185 mm2 max. or 150 mm2 max. (flexible) Adaptor for lug For connecting bare cables with wide lug Set of 1 adaptor + insulated shields Extended front terminals Set of 4 Spreaders Set of spreaders incoming or outgoing Rear terminals Used to convert the fixed version with front terminals to the fixed version with rear terminals Set of rear terminals, incoming or outgoing Set of flat rear terminals, incoming or outgoing Distribution terminal 250 A 250 A - 4 outputs 35 mm2 flexible and 2 outputs 25 mm2 flexible - Isc peak 36 k Can be fitted directly onto downstream terminal of DPX 250/250 ER and DPX-IS 250 :FNJC,)& j^[hcWbcW]d[j_YWdZ[b[Yjhed_Yh[b[Wi[C998i\hec(+&je,)&7 Green indicator lamp (only S1): normal operation minimum current for indicator lamp operation (30 % of In) Fixed red indicator lamp: ≥ 0.9 Ir Flushing red indicator lamp: I ≥ 1.05 Ir connector for test unit 0 255 40 0 255 53 0 256 07 Dimensions see e-catalogue Electrical characteristics p. 130 Moulded case MCCBs for switching, control isolation and protection of low voltage electrical lines Can be fitted with auxiliaries (p. 144) Can be used with earth leakage modules or with residual current relays (p. 145) Supplied complete with: - connection plates for bars - terminal shields Conform to IEC 60947-2 - Sealable adjustment Can be mounted on plate in XL3 cabinets and enclosures Pack DPX 630 thermal magnetic Cat.Nos Pack DPX 630 electronic release S1 Cat.Nos Adjustment of Ir, Im (p. 146) Instantaneous protection If = 5 kA Green indicator lamp Connector for test unit Dynamic selectivity 4P version: adjustement of neutral on front panel Thermal adjustable from 0.8 to 1 In Magnetic adjustable from 5 to 10 In t Ir Ii t I 1 1 1 1 1 3P 4P 0 255 21 0 255 22 0 255 23 0 255 25 0 255 24 0 255 36 0 255 37 0 255 38 0 255 39 0 255 40 3P + N/2 0 255 32 0 255 33 0 255 35 0 255 34 1 1 1 1 1 1 1 1 3P 4P 0 255 42 0 255 43 0 255 45 0 255 44 0 255 57 0 255 58 0 255 59 0 255 60 3P + N/2 1 1 1 1 0 255 52 0 255 53 0 255 55 0 255 54 DPX 630 36 kA Breaking capacity Icu 36 kA (400 V±) In 250 A 320 A 400 A 500 A 630 A In 320 A 400 A 500 A 630 A DPX-H 630 70 kA Breaking capacity Icu 70 kA (400 V±) In 320 A 400 A 500 A 630 A In 320 A 400 A 500 A 630 A Ir Ii 3P 4P 1 1 1 0 256 01 0 256 05 0 256 02 0 256 06 0 256 03 0 256 07 1 1 0 256 10 0 256 14 0 256 11 0 256 15 If I DPX 630 36 kA Breaking capacity Icu 36 kA (400 V±) In 250 A 400 A 630 A DPX-H 630 70 kA Breaking capacity Icu 70 kA (400 V±) In 400 A 630 A 139 www.klinkmann.com www :FNJC,)& :FNJC,)& j^[hcWbcW]d[j_YWdZ[b[Yjhed_Yh[b[Wi[C998i \hec(+&je,)&7Yedj_dk[Z ■ Performance data S1 - Adjustment of Ir, Im t Ir Ii If 0 256 35 s,ONGDELAYPROTECTIONAGAINSTOVERLOADSWITHANADJUSTABLETHRESHOLD based on the rms value of the current: Ir = 0.4 - 0.5 - 0.7 - 0.8 - 0.95 - 1 x In (8 steps) Tr = 5 s (fixed at 6 tr) s3HORTDELAYPROTECTIONAGAINSTSHORTCIRCUITSWITHANADJUSTABLE)M threshold: Im = 1.5 - 2 - 3 - 4 - 5 - 6 - 8 - 10 x Ir (8 steps) Tm = 0.05 s (fixed) s)NSTANTANEOUSPROTECTION if with fixed threshold: If = 5 kA 0 260 63 Pack DPX 630 electronic release S2 Cat.Nos Adjustment of Ir, Im, Tr, Tm (opposite) Instantaneous protection If = 5 kA Green indicator lamp Connector for test unit Logic and dynamic selectivity 4P version: adjustement of neutral on front panel t Isd Tsd I2t I 3P 4P 0 256 26 0 256 30 0 256 27 0 256 31 0 256 28 0 256 32 1 1 0 256 35 0 256 39 0 256 36 0 256 40 1 1 0 256 43 0 256 47 0 256 44 0 256 48 S2 - Adjustment of Ir, Tr, Im, Tm t DPX 630 36 kA Breaking capacity Icu 36 kA (400 V±) In 250 A 400 A 630 A DPX-H 630 70 kA Breaking capacity Icu 70 kA (400 V±) In 400 A 630 A DPX-L 630 100 kA Breaking capacity Icu 100 kA (400 V±) In 400 A 630 A Tm If 1 1 I s,ONGDELAYPROTECTIONAGAINSTOVERLOADSWITHANADJUSTABLETHRESHOLD based on the rms value of the current: Ir = 0.4 - 0.5 - 0.7 - 0.8 - 0.9 - 0.95 - 1 x In (8 steps) Tr = 5 - 10 - 20 - 30 s (at 6 Ir) (4 steps) s3HORTDELAYPROTECTIONAGAINSTSHORTCIRCUITSWITHANADJUSTABLE)M threshold: Im = 1.5 - 2 - 3 - 4 - 5 - 6 - 8 - 10 x Ir (8 steps) Tm = 0 - 0.1 - 0.2 - 0.3 s (4 steps) Tm = 0.01 - 0.1 - 0.2 - 0.3 s at 12 x Ir (I2 t constant) (4 steps) s)NSTANTANEOUSPROTECTIONAGAINSTSHORTCIRCUITS with fixed threshold: If = 5 kA Earth leakage modules 1 1 Ir Tr Im Ir Tr 1 1 1 I Can be fitted onto DPX/DPX-I 630 Adjustable, sealable sensitivity: 0.03 - 0.3 - 1 - 3 A Adjustable, time delay: 0 - 0.3 - 1 - 3 s Test push-button Reset push-button Remote earth fault signalling contact Switch for mechanical tests (installation insulation test) Mounted underneath 230-500 V± Standard 3P 4P In 0 260 60 0 260 61 400 A 0 260 64 0 260 65 630 A LED version Monitors the isolation state of the installation via a series of LEDs 4P In 0 260 63 400 A 0 260 67 630 A For DPX-L 100 kA and Sg electronic release version, please consult us 140 www.klinkmann.com www :FNJC,)& [gk_fc[djWdZWYY[iieh_[i 0 265 57 0 265 67 Pack Plug-in version Cat.Nos 3P 0 262 50 4P 1 0 265 50 0 265 51 1 1 0 265 52 0 265 53 0 265 54 0 265 55 1 0 265 56 0 265 57 1 1 0 265 58 0 265 59 4P 1 0 265 60 1 1 0 263 68 0 263 99 Pack A plug-in is a DPX fitted with tulip contacts mounted on a base Tulip contacts Set of tulip contacts (supplied with an incoming/outgoing protective cover) Bases for DPX only Accept DPX/DPX-I fitted with tulip contacts Front terminal mounting base Rear terminal mounting base with threaded rod Flat rear terminal mounting base Bases for DPX with earth leakage module Front terminal mounting base Rear terminal mounting base with threaded rod Flat rear terminal mounting base Accessories Set of 2 extractor handle Set of connectors (8-pin) Draw-out version 1 1 1 1 1 1 A DPX draw-out version is a plug-in DPX fitted with a "Debro-lift" mechanism which can be used to withdraw the DPX while keeping it on its base "Debro-lift" mechanism Supplied with a rigid slide and handle for 3P 4P drawing-out 0 265 66 0 265 67 For DPX base only 0 265 68 For DPX base with earth leakage module Key-lock for "Debro-lift" mechanism Enable locking of DPX in drawn-out position 0 265 76 One key Ronis for DPX only 0 265 78 One key Ronis for motorised DPX or with rotary handle Accessories for "Debro-lift" mechanism 0 265 75 Isolated handle for drawing-out 0 265 74 Signalling contact (plugged-in/drawn-out) 1 1 0 262 81 0 262 82 1 1 1 1 0 262 92 0 262 93 0 262 94 0 262 25 0 264 09 1 0 264 04 Vari-depth handle IP 55 Comprising: connection rod, bracket, self-adhesive drilling template, mounting accessories and door lock mechanism Standard (grey) For emergency use (red/yellow) can be fitted on Cat.Nos 0 262 81 or 0 262 41 Locking accessories Eurolocks for vari-depth handle Profalux for vari-depth handle Ronis for vari-depth handle Eurolocks for direct handle Motor-driven handles 1 1 0 261 40 0 261 44 1 1 0 261 59 0 261 58 Front operated 24 V±/= 230 V± Accessories Ronis locking accessory Profalux locking accessory Accessories 1 0 262 30 1 0 262 44 0 262 45 1 0 262 40 1 0 262 50 1 0 262 51 1 0 262 46 3P Supply invertor type 1 0 262 48 Rotary handles (continued) Cat.Nos 4P 0 262 47 1 3P Factory assembled A supply invertor type is composed of one plate with interlock for 2 devices Plate for MCCB or trip-free switch fixed version Plate for MCCB or trip-free switch plug-in and draw-out version 0 262 51 4P 1 0 262 48 0 262 49 1 0 263 50 0 263 51 1 0 263 52 0 263 53 Insulated shields Set of 3 Sealable terminal shields Set of 2 Padlock For locking in "OPEN" position Cage terminals Set of 4 terminals for cable 300 mm2 max. (rigid) or 240 mm2 max. (flexible) Set of 4 high-capacity terminals for cable 2 x 240 mm2 (rigid) or 2 x 185 mm2 (flexible) Adaptor for lug For connecting bare cables with wide lugs Set of 4 adaptors + insulated shields Extended front terminals Set of 4 Spreaders Set of incoming or outgoing spreaders Rear terminals Used to convert the fixed version with front terminals to the fixed version with rear terminals Set of incoming or outgoing swivel terminals Set of incoming or outgoing flat terminals Rotary handles 1 1 0 262 41 0 262 24 Direct on DPX Standard (grey) For emergency use (red/yellow) - can be fitted on Cat.Nos 0 262 22, 0 262 41 or 0 262 81 141 www.klinkmann.com www :FNJC'(+&#',&& j^[hcWbcW]d[j_YWdZ[b[Yjhed_Yh[b[Wi[C998i\hec.&&je',&&7 DPX Auxiliaries 0 257 08 0 258 04 p. 144 Dimensions see e-catalogue Electrical characteristics p. 130 Moulded case MCBs for switching, control isolation and protection of low voltage electrical lines Can be fitted with auxiliaries (integrated terminal blocks) Can be used with earth leakage modules or with residual current relays (p. 145) Supplied complete with: - connection plates for bars - terminal shields Conform to IEC 60947-2 Fixed version - Sealable adjustment Pack Cat.Nos Pack Cat.Nos DPX 1250 thermal magnetic Thermal adjustable from 0.8 to 1 In Magnetic adjustable from: 5 to 10 In 3P t Ir 1 1 1 0 257 02 0 257 03 0 257 04 1 1 1 0 257 10 0 257 11 0 257 12 Ii I 3P 1 1 1 0 258 02 0 258 03 0 258 04 1 1 1 0 258 16 0 258 17 0 258 18 DPX 1250 50 kA Breaking capacity Icu 50 kA (400 V±) 4P In 1 0 258 09 800 A 1 0 258 10 1000 A 0 258 111 1250 A DPX-H 1250 70 kA Breaking capacity Icu 70 kA (400 V±) In 1 0 258 23 800 A 1 0 258 24 1000 A 0 258 251 1250 A DPX 1600 electronic release S1 Adjustment of Ir, Im Instantaneous protection If = 20 kA Indicator lamp Minimum current for indicator lamp operation (30 % In): green: t normal; Ir fixed red: I ≥ 0.9 Ir; flashing red: I ≥ 1.05 Ir Connector for test unit Ii Dynamic selectivity If DPX 1600 50 kA Breaking capacity Icu 50 kA (400 V±) 4P In 0 257 062 800 A 0 257 072 1250 A 0 257 082 1600 A DPX-H 1600 70 kA Breaking capacity Icu 70 kA (400 V±) In 2 0 257 14 800 A 2 0 257 15 1250 A 0 257 162 1600 A I DPX 1600 electronic release S2 3P 1 1 1 0 257 26 0 257 27 0 257 28 1 1 1 0 257 34 0 257 35 0 257 36 For DPX-L 100 kA and Sg electronic release version, please consult us Adjustment of Ir, Im, Tr, Tm Instantaneous protection If = 20 kA Indicator lamp Minimum current for indicator lamp operation (30 % In): green: t normal; Ir fixed red: I ≥ 0.9 Ir; Tr flashing red: I ≥ 1.05 Ir Isd Connector for test unit Tsd Logic and dynamic I2t selectivity DPX 1600 50 kA Breaking capacity Icu 50 kA (400 V±) 4P In 0 257 302 800 A 0 257 312 1250 A 0 257 322 1600 A DPX-H 1600 70 kA Breaking capacity Icu 70 kA (400 V±) In 0 257 382 800 A 0 257 392 1250 A 0 257 402 1600 A 1: Neutral without protection 2: Neutral settings 0 - 0.5 - 1 N (0 - 50% - 100% Neutral) 142 www.klinkmann.com www I :FNJC'(+&#',&& [gk_fc[djWdZWYY[iieh_[i 0 265 84 (supplied assembled) Pack 1 1 1 1 1 1 Cat.Nos 0 262 60 0 262 70 Draw-out version Pack A DPX draw-out version is a plug-in DPX fitted with a "Debro-lift" mechanism which can be used to withdraw the DPX while keeping it on its base Draw-out base Base for DPX 1600 supplied with "Debro-lift" assembled a rigid slide and 3P 4P handle for drawing-out 0 265 82 0 265 83 Front terminals 0 265 84 0 265 85 Rear terminals Key lock for "Debro-lift" mechanism Enable locking of DPX in drawn-out position 0 265 76 One key Ronis for DPX only 0 265 80 Two key Ronis (one key supplied) for motorised DPX or with rotary handle Accessories for "Debro-lift" mechanism 0 265 75 Isolated handle for drawing-out 0 265 74 Signalling contact (plugged-in/drawn-out) Motor-driven handles Cat.Nos 1 0 261 54 1 1 1 1 1 1 1 1 0 261 24 0 261 25 0 261 26 0 261 23 0 261 19 0 261 28 0 261 29 0 261 27 1 1 0 261 59 0 261 58 0 264 10 1 0 264 05 1 0 262 61 1 1 0 262 83 0 262 84 1 1 1 1 0 262 92 0 262 93 0 262 94 0 262 25 A supply invertor type is composed of one plate with interlock for 2 devices Plate for MCCBs or trip-free switch fixed version Plate for MCCBs or trip-free switch plug-in and draw-out version 1 Rotary handles Direct on DPX Standard (black) Vari-depth handle IP 55 Comprising: connection rod, bracket, self-adhesive drilling template, mounting accessories and door lock mechanism Standard (black) For emergency use (red/yellow) Locking accessories Eurolocks for vari-depth handle Profalux for vari-depth handle Ronis for vari-depth handle Eurolocks for direct handle Factory assembled Front operated 230 V± Customer assembled Front operated 24 V±/= for In ≤ 1250 A 48 V±/= for In ≤ 1250 A 110 V±/= for In ≤ 1250 A 230 V±/= for In ≤ 1250 A 24 V±/= for In = 1600 A 48 V±/= for In = 1600 A 110 V±/= for In = 1600 A 230 V±/= for In = 1600 A Locking accessories Ronis locking accessory Profalux locking accessory Accessories Supply invertor type 1 0 262 67 + 0 262 68 0 262 66 3P 4P 1 0 262 64 0 262 65 1 0 262 60 1 0 262 69 1 0 262 70 1 0 262 67 1 0 262 68 1 0 262 73 0 262 74 1 1 0 263 80 0 263 82 0 263 81 0 263 83 3P 4P Insulated shields Used to isolate the connections between each pole Set of 3 Sealable terminal shields Set of 2 Padlock For locking in "open" position Cage terminals Set of 1 terminal for cables without lug 2 x 240 mm2 for rigid cable or 2 x 185 mm2 for flexible cable Set of 1 high-capacity terminal for cables without lug 4 x 240 mm2 for rigid cable 4 x 185 mm2 for flexible cable Extended front terminals Set of 4 Short terminals for 630 - 1250 A (2 bars max. per pole) Long terminals for 1600 A (3 bars max. per pole) Spreaders Set of incoming or outgoing spreaders Rear terminals Used to convert the fixed version with front terminals to the fixed version with rear terminals Set of incoming or outgoing rear terminals Short terminals Long terminals Red catalogue numbers: New products 143 www.klinkmann.com www :FNJCWkn_b_Wh_[i 0 261 85 :FNJCWkn_b_Wh_[i Auxiliary contact or fault signal A singly Cat.No 0 261 60 auxiliary contact or fault signal 0 261 93 Pack Cat.Nos Auxiliary contact or fault signal 1 0 261 60 For signalling the state of the contacts or opening of the MCCB on a fault For DPX/DPX-I/DPX-IS Changeover switch 3 A - 240 V± Releases 1 1 1 1 1 0 261 64 0 261 65 0 261 66 0 261 67 0 261 68 For DPX/DPX-I 160, DPX/DPX-I 125 250ER, 630, DPX-IS 250, 1250, 1600 and 630 DPX-IS 1600 1 1 1 1 1 1 0 261 70 0 261 71 0 261 72 0 261 76 0 261 73 0 261 74 0 261 80 0 261 81 0 261 82 0 261 86 0 261 83 0 261 84 1 1 1 0 261 90 0 261 91 0 261 75 1 0 261 85 Allow remote tripping of a DPX Shunt releases For DPX-IS/DPX-I and DPX Shunt inrush power 300 VA Coil voltage 24 V±/= Coil voltage 48 V±/= Coil voltage 110 V±/= Coil voltage 230 V±/= Coil voltage 400 V±/= Undervoltage releases Undervoltage releases For DPX-IS/DPX-I and DPX Undervoltage power consumption 5 VA Coil voltage 24 V= Coil voltage 24 V± Coil voltage 48 V= Coil voltage 110 V± Coil voltage 230 V± Coil voltage 400 V± Time-lag (ms) undervoltage releases Allow remote tripping of a DPX Prevent false tripping in the event of AC supply microbreaks Require a time-lag module connected to the undervoltage Number of modules releases below Time-lag modules 230 V± 3 Time-lag modules 400 V± 3 Undervoltage releases For DPX/DPX-I 125, DPX -IS 250,630 Undervoltage releases For DPX/DPX-I 160, 250ER, 630, 1250, 1600 and DPX -IS 1600 Shunt releases Time-lag undervoltage releases Max. number of contacts per DPX-IS device Electronic test unit 1 0 261 97 Test connector and software for connecting DPX to a PC Supplied with test software Automation control unit 1 1 0 261 93 0 261 94 Auxiliary contact AC EBAC FS Shunt release or undervoltage release Device For setting the conditions for supply inversion, generator on loft status acquisition for DMX and DPX circuitbreakers, open/closed Power supply: 230 V± and 12-24-48 V= Connection by plug-in terminals Standard unit Communicating unit, enabling data transmission (RS 485 port) Without release DPX-IS 250 1 2 – – With release DPX-IS 250 1 1 1 1 AC = auxiliary contact EBAC = "early" auxiliary contact FS = break on trip contact Max. number of contacts per DPX device Auxiliary contact AC FS Shunt release or undervoltage release DPX 125 1 1 1 DPX 160 1 1 1 DPX 250 ER 1 1 1 DPX 250 2 1 1 DPX 630 2 2 1 DPX 1600 3 1 1 Device 144 www.klinkmann.com www h[i_ZkWbYkhh[djh[bWoWdZYe_bi h[i_ZkWbYkhh[djh[bWoWdZYe_bi ■ Residual current relay Cat.No 0 260 88 0 260 98 90 45 35 88 0 260 88 60 44 6 35 0 260 93 coil for use with relay Add residual current protection to DPX trip-free switches and DPX MCCBs equipped with release M 5 D D C C A L L 22 6 Cat.No 0 260 97 E 5.5 B 45 34 E 79 H M Cat.Nos 0 260 92/93/94/95/96 B Cat.Nos 0 260 92 0 260 93 0 260 94 0 260 95 0 260 96 0 260 97 A 35 80 110 140 210 150 B 75 108 148 177 270 225 C 85 132 170 206 295 259 D 42 67 86 104 150 133 E 92 125 165 200 290 245 H 36 36 36 36 44 275 L 43 65 84 102 145 95 M 56 56 56 56 64 113 0 260 88 Residual current relay to clip on rail 2 2 Cat.No 0 260 98 21 1 Coils 0 260 92 0 260 93 0 260 94 0 260 95 0 260 96 0 260 97 0 260 98 For use with residual current relay Cat.No 0 260 88 1 coil per DPX Coil Ø35 mm Coil Ø80 mm Coil Ø110 mm Coil Ø140 mm Coil Ø210 mm Coil Ø150 mm - open Coil Ø300 mm - open Viking 3 disconnector block for measurement 1 connection With its accessories, allows intervention (measurement, maintenance, etc) on a current, voltage and power measuring circuit by keeping the current transformer secondary circuit closed 25 0 371 92 Colour Nominal cross section (mm2) Grey 4 Capacity rigid Flexible wire wire (mm2) (mm2) 0.25 to 4 0.25 to 4 5 1 1 1 1 1 1 1 7 Number of modules 58 Detects fault currents, and, when used with a shunt trip or an undervoltage release, it gives the trip command to a MCCB or a switch s#OMPRISES - a tinged, sealable window - an auxiliary contact - a green Led indicating energisation - 3 yellow Leds indicating respectively the max. phase earth insulation current: 20, 40 and 60 % - a red Led indicating Fixed: exceeding of the insulation fault current value Flashing: breaking of one of the connections between coils and relays s&ORUSEWITHCOILS - Ø35 and 80 mm Adjustable sensitivity: 0.03, 0.05, 0.075, 0.1, 0.15, 0.2, 0.3, 0.5, 0.75, 1, 1.5, 2, 3, 5, 7.5, 10, 15, 20, 30 A - Ø110 to 210 mm Adjustable sensitivity: 0.3, 0.5, 0.75, 1, 1.5, 2, 3, 5, 7.5, 10, 15, 20, 30 A - Ø150 mm Adjustable sensitivity: 0.5, 0.75, 1, 1.5, 2, 3, 5, 7.5, 10, 15, 20, 30 A - Ø300 mm Adjustable sensitivity: 1, 1.5, 2, 3, 5, 7.5, 10, 15, 20, 30 A s!DJUSTABLETRIPSECONDS s3UPPLYVOLTAGE6(Z H ■ Coils Residual current relay 23 Cat.Nos A Pack 310 30 368 400 Pitch (mm) 8 145 www.klinkmann.com www :FNJC h[WZ_d]:FNY^WhWYj[h_ij_YYkhl[iWdZWZ`kijc[djhWd][i ■ Tripping curve for a DPX thermal-magnetic trip ■ Tripping curve for a DPX electronic release S2, adjustable Ir, Im, Tr and Tm 10 000 10 000 t (s) t (s) Thermal realease zone when cold 1 000 Tr = 30 s 20 % Tr = 20 s 20 % Tr = 10 s 20 % 1 000 Tr = 5 s 20 % 100 100 Isf = 250 A Isf = 160 A 10 10 Thermal realease zone when hot Isf = 100 A Isf = 40 A I2t = K Im 1 Isf = 630 A Isf = 400 A Isf = 1600 A Isf = 1250 A Isf = 160 A Isf = 250 A Isf = 630 A Isf = 800 A 1 0.1 Adjustable magnetic realease zone 0.1 Tm 0.01 Im 0.001 0.01 0.001 0.2 1 1 2 3 4 5 10 20 30 50 100 I/Ir I: actual current Ir: thermal protection against overloads (setting: Ir = x In) Im: magnetic protection against short-circuits (setting: Im = x In or Im = x Ir) As the abscissa of the curves represents the ratio I/Ir, modifying the setting of Ir will not CHANGETHEGRAPHICALREPRESENTATIONOFTHETHERMALTRIP(OWEVERTHEMAGNETICSETTINGCANBE read directly (between 3.5 and 10 in the example). 2 3 4 5 I/Ir 10 10 20 304050 I/In 10 20 30 10 I/In 20 30 I/In I: actual current Ir: long delay protection against overloads (setting: Ir = x In) Tr: long delay protection operation time (fixed value: 5 to 30 s) Im: short delay protection against short-circuits (setting: Im = x Ir, between 1.5 and 10 Ir in the example) Tm: short delay protection operation time (setting: 0 to 0.3 s) I2t constant (adjustable via Tm) If: fixed threshold instantaneous protection (4 to 20 kA depending on model) ■ Adjustment for thermal-magnetic DPX ■ Tripping curve for a DPX electronic release S1, adjustable Ir and Im 10 000 t (s) 1 000 Setting DPX 125 DPX 160 DPX 250 ER DPX 250 DPX 630 DPX 1250 Ir overload trip threshold (long delay) 0.7 to 1 In 0.64 to 1 In 0.64 to 1 In 0.8 to 1 In 0.8 to 1 In Im short-circuit trip threshold (short delay) fixed: 10 In (100 and 125 rating) fixed: 10 In 3.5 to 10 In 5 to 10 In 5 to 10 In 100 Isf = 40 A 10 Tr = 5 s Isf = 630 A Isf = 250 A 1 Isf = 160 A Im Isf = 160 A Isf = 400 A Isf = 100 A 0.1 Isf = 1600 A Isf = 250 A Isf = 630 A ■ Adjustment for DPX electronic release Isf = 1250 A Setting Isf = 800 A Ir overload trip threshold (long delay) 0.01 DPX 250 / 630 / 1600 S1 DPX 250 / 630 / 1600 S2 0.4 - 0.5 - 0.6 - 0.7 - 0.8 - 0.9 - 0.95 - 1) x In Tr long delay fixed: 5 s (to 6 Ir) 5 - 10 - 20 - 30 s (to 6 Ir) trip time 0.001 0.2 1 2 3 4 56 10 I/Ir 10 20 30 40 50 70 I/In 10 20 30 10 I/In 20 I/In Im short-circuit trip threshold (short delay) I: actual current Ir: long delay protection against overloads (setting: Ir = x In) Tr: long delay protection operation time (fixed value: 5 s at 6 Ir) Im: short delay protection against short-circuits (setting: Im = x Ir, between 1.5 and 10 Ir in the example) Tm: short delay protection operation time (fixed value: 0.1 s) If: fixed threshold instantaneous protection (4 to 20 kA depending on model) (1.5 - 2 - 3 - 4 - 5 - 6 - 8 - 10) x Ir(1) Tm Short delay fixed: 0.05 s trip time 1: 7.9 Ir for DPX 630 In 630 A 146 www.klinkmann.com www 0 - 0.1 - 0.2 - 0.3 s i[b[Yj_l_jojWXb[:FNJC%:FNJCj^[hcWb#cW]d[j_Y ■ Limits of selectivity (three phase circuit at 400 V) Upstream MCCB DPX Downstream MCCB DPX DPX 125 (16 kA) DPX 125 (25 kA) DPX 125 (36 kA) DPX 160 DPX 250ER (25 kA) DPX 160 DPX 250ER (36 kA) DPX 160 DPX 250ER (50 kA) DPX 250 (36 kA) DPX 250 S1/S2 (36 kA) DPX-H/L 250 (70/100 kA) DPX-H/L 250 S1/S2 (70/100 kA) DPX 630 (36 kA) DPX-H/L 630 (70/100 kA) DPX 630 S1/S2 (36 kA)(1) DPX-H/L 630 S1/S2 (70/100 kA)(1) DPX 1250 (50 kA) DPX-H 1250 (70 kA) In (A) Ist. (kA) 16 25 40 63 100 125 16 25 40 63 100 125 16 25 40 63 100 125 63 100 160 250 63 100 160 250 40 63 100 160 250 40 63 100 160 250 40 100 160 250 40 63 100 160 250 40 100 160 250 250 320 400 500 630 250 320 400 500 630 250 400 630 400 630 800 1000 1250 800 1000 1250 DPX 125 (16 kA) DPX 125 (25 kA) DPX 125 (36 kA) 40 0.8 0.8 0.8 63 100 125 0.95 1.25 1.25 1 1.2 1.2 1 1.2 1.2 1 1.2 1.2 1.2 1.2 DPX 160 (25 kA) DPX 250ER (25 kA) DPX 160 (36 kA) DPX 250ER (36 kA) DPX 160 (50 kA) DPX 250ER (50 kA) 63 0.63 0.63 100 1 1 1 1 160 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 250 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 1 1.6 1.6 2.5 2.5 2.5 1 1 1.6 1.6 1.6 2.5 2.5 2.5 2.5 0.8 0.8 1 1 1 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 0.63 1 1 1 0.8 0.8 1 1 1 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 0.63 1 1 1 1 0.63 DPX 250 DPX-H 250 63 0.63 0.63 100 1 1 1 1 0.63 1 1 1 0.63 1 1 1 160 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 250 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 250 2.5 6 6 6 6 4 4 6 6 6 6 4 4 6 6 6 6 4 4 2.5 2.5 2.5 1 1.6 1.6 2.5 2.5 2.5 2.5 2.5 2.5 1 1 1.6 1.6 1.6 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 1 1.6 1.6 2.5 2.5 2.5 2.5 2.5 2.5 2.5 1 1 1.6 1.6 1.6 2.5 2.5 2.5 2.5 2.5 2.5 2.5 2.5 1 0,63 0,63 DPX 630 DPX-H 630 DPX 1250 DPX-H 1250 320 3.2 6 6 6 6 4 4 6 6 6 6 4 4 6 6 6 6 4 4 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 400 4 6 6 6 6 4 4 6 6 6 6 4 4 6 6 6 6 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 500 5 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 630 6.3 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 6.3 3.2 4 4 5 5 5 6.3 6.3 6.3 6.3 6.3 6.3 6.3 800 8 T T T T T T 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 10 10 10 10 10 10 10 10 10 10 8 8 8 8 8 1000 6 T T T T T T 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 10 10 6 6 6 10 10 6 6 6 6 6 6 6 6 7.5 1250 7.5 T T T T T T 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 10 10 7.5 7.5 7.5 10 10 7.5 7.5 7.5 8 8 8 8 8 7.5 7.5 7.5 7.5 7.5 1: Selectivity low 147 www.klinkmann.com www i[b[Yj_l_jojWXb[:FNJC%:FNJC[b[Yjhed_YI'%I( ■ Limits of selectivity low (three-phase circuit at 400 V) ■ Limits of selectivity high (three phase circuit at 400 V) Upstream MCCB electronic SEL: LOW Downstream MCCB DPX DPX 125 (16 kA) DPX 125 (25 kA) DPX 125 (36 kA) DPX 160 DPX 250ER (25 kA) DPX 160 DPX 250ER (36 kA) DPX 160 DPX 250ER (50 kA) DPX 250 (36 kA) DPX 250 S1/S2 (36 kA) DPX-H 250 (70 kA) DPX-H 250 S1/S2 (70 kA) DPX 630 (36 kA) DPX-H 630 (70 kA) DPX 630 S1/S2 (36 kA)(1) DPX-H 630 S1/S2 (70 kA)(1) DPX 1250 (50 kA) DPX-H 1250 (70 kA) DPX/DPX-H 1600 S1 (50/70 kA)(1) DPX 250 S1/S2 (36 kA) DPX-H 250 S1/S2 (70 kA) DPX In (A) Ist. (kA) 16 25 40 63 100 125 16 25 40 63 100 125 16 25 40 63 100 125 63 100 160 250 63 100 160 250 40 63 100 160 250 40 63 100 160 250 40 100 160 250 40 63 100 160 250 40 100 160 250 250 400 500 630 250 320 400 500 630 250 400 630 400 630 800 1000 1250 500 630 800 1000 1250 800 DPX/DPX-H 1600 S2 (50/70 kA)(1) 800 DPX/DPX-H 1600 S1/S2 (50/70 kA)(1) 1250 1600 40 3.5 3.5 3.5 3.5 3.5 3.5 3.5 100 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 Upstream MCCB electronic SEL: HIGH DPX 600 S1/S2 (36 kA) DPX-H 630 S1/S2 (70 kA) 160 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 250 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 250 5 8 8 6 6 6 6 8 8 6 6 6 6 8 8 6 6 6 6 6 6 6 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 6 6 6 3.5 3.5 3.5 3.5 8 6 6 6 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 8 8 8 8 1 1.6 1.6 2.5 2.5 2.5 8 6 6 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 8 8 8 8 1 1.6 1.6 2.5 2.5 2.5 8 6 6 400 5 8 8 6 6 6 6 8 8 6 6 6 6 8 8 6 6 6 6 6 6 6 6 6 6 6 6 8 6 6 6 6 8 8 8 8 6 8 8 8 6 8 8 8 8 6 8 6 6 6 6 630 5 8 8 6 6 6 6 8 8 6 6 6 6 8 8 6 6 6 6 6 6 6 6 6 6 6 6 8 6 6 6 6 8 8 8 8 6 8 8 8 6 8 8 8 8 6 8 6 6 6 6 6 6 6 6 6 6 5 5 5 5 DPX/DPX-H 1600 S1 (50/70 kA) DPX/DPX-H 1600 S2 (50/70 kA) 800 10 T T T T T T T T T T T T 25 25 25 25 25 25 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 15 15 10 10 15 15 15 10 10 15 15 15 15 15 800 10 T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T 30 30 30 30 30 30 30 30 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 15 15 20 20 DPX/DPX-H 1600 S1,S2 (50/70 kA) 1250 15 T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T 30 30 30 30 30 30 30 30 30 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 15 15 Downstream MCCB 1600 20 T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T 36 36 36 36 36 36 36 36 36 T T T T 36 36 36 36 36 T T T 36 36 20 20 20 20 20 20 20 20 DPX DPX 125 (16 kA) DPX 125 (25 kA) DPX 125 (36 kA) DPX 160 DPX 250ER (25 kA) DPX 160 DPX 250ER (36 kA) DPX 160 DPX 250ER (50 kA) DPX 250 (36 kA) DPX 250 S1/S2 (36 kA) DPX-H 250 (70 kA) DPX-H 250 S1/S2 (70 kA) DPX 630 (36 kA) DPX-H 630 (70 kA) DPX-H 630 S1/S2 (36 kA)(1) DPX 630 S1/S2 (70 kA)(1) DPX 1250 (50 kA) DPX-H 1250 (70 kA) DPX 250 S1/S2 (36 kA) DPX-H 250 S1/S2 (70 kA) DPX In (A) Ist. (kA) 16 25 40 63 100 125 16 25 40 63 100 125 16 25 40 63 100 125 63 100 160 250 63 100 160 250 40 63 100 160 250 40 63 100 160 250 40 100 160 250 40 63 100 160 250 40 100 160 250 250 400 500 630 250 320 400 500 630 250 400 630 400 630 800 1000 1250 500 630 800 1000 1250 40 3.5 T T 100 3.5 T T T T T T T T T T 25 25 25 25 25 25 DPX 630 S1/S2 (36 kA) DPX-H 630 S1/S2 (70 kA) 160 3.5 T T T T T T T T T T T T 25 25 25 25 25 25 25 25 250 3.5 T T T T T T T T T T T T 25 25 25 25 25 25 25 25 25 250 5 T T T T T T T T T T T T T T T T T T T T T 25 25 25 25 25 25 T T T 25 25 25 25 25 25 25 25 25 36 36 36 36 36 36 36 36 36 36 36 36 36 T T T T T T T T T T T T T 36 36 36 36 36 36 36 36 36 36 36 36 36 25 36 36 36 400 5 T T T T T T T T T T T T T T T T T T T T T T T T T T 36 36 36 36 36 T T T T T T T T T 36 36 36 36 36 36 36 36 36 630 5 T T T T T T T T T T T T T T T T T T T T T T T T T T 36 36 36 36 36 T T T T T T T T T 36 36 36 36 36 36 36 36 36 25 25 25 25 25 25 25 DPX/DPX-H 1600 S1 (50/70 kA) DPX/DPX-H 1600 S2 (50/70 kA) DPX/DPX-H 1600 S1,S2 (50/70 kA) 800 10 T T T T T T T T T T T T T T T T T T T T T T T T T T 36 36 36 36 36 T T T T T T T T T 36 36 36 36 36 36 36 36 36 T T T T 36 36 36 36 36 T T T 36 36 800 10 T T T T T T T T T T T T T T T T T T T T T T T T T T 36 36 36 36 36 T T T T T T T T T 36 36 36 36 36 36 36 36 36 T T T T 36 36 36 36 36 T(1) T(1) T(1) 36(1) 36(1) 1250 15 T T T T T T T T T T T T T T T T T T T T T T T T T T 36 36 36 36 36 T T T T T T T T T 36 36 36 36 36 36 36 36 36 T T T T 36 36 36 36 36 T(1) T(1) T(1) 36(1) 36(1) 36 36 36 36 36 36 36 36 36 36 20 DPX/DPX-H 1600 S1 (50/70 kA)(1) 800 36 20 DPX/DPX-H 1600 S2 (50/70 kA)(1) 800 36(1) DPX/DPX-H 1600 S1/S2 (50/70 kA)(1) 1250 1600 20 1600 20 T T T T T T T T T T T T T T T T T T T T T T T T T T 36 36 36 36 36 T T T T T T T T T 36 36 36 36 36 36 36 36 36 T T T T 36 36 36 36 36 T(1) T(1) T(1) 36(1) 36(1) 36 36 36 36 36 36 36 36 36 36(1) 36(1) 1: Selectivity low For S2 tripping unit possibility of logic selectivity (total selectivity) 1: Selectivity low 148 149 www.klinkmann.com www i[b[Yj_l_jojWXb[i_da7nnnnnn C998i%C98i Upstream device DPXE 125 / DPX 125 (25 kA & 36 kA) DXE 6000 - 6 kA B & C curve RX3 4500 B & C curve RX3 6000 B & C curve DX3 6000 - 10 kA B & C curve DX3 10000 - 16 kA B & C curve DX3 10000 - 16 kA D curve DX3 25 kA C curve DX3 25 kA D curve DX3 50 kA C curve DX3 50 kA D curve In (A) 6 10 13 16 20 25 32 40 50 63 ≤6 10 13 16 20 25 32 40 50 63 ≤6 10 13 16 20 25 32 40 50 63 ≤6 10 13 16 20 25 32 40 50 63 ≤6 10 16 20 25 32 40 50 63 80 100 125 80 100 125 ≤6 10 16 20 25 32 40 50 63 80 100 125 ≤6 10 16 20 25 32 40 50 63 80 100 125 10 16 20 25 32 40 50 63 10 16 20 25 32 40 50 63 16 T 5 25 T 5 4 4 3 40 T 5 4 4 3 3 63 T 5 4 4 3 3 2 2 T T T T 4 4 4 T T 4 4 4 3 3 T T 4 4 4 3 3 3 T 5 T 5 4 4 4 T 5 4 4 4 3 3 T 5 4 4 4 3 3 3 6 5 6 5 4 4 4 6 5 4 4 4 3 3 6 5 4 4 4 3 3 3 6 5 6 5 4 4 6 5 4 3 3 6 5 4 3 3 2 2 100 T T T T 5 4.5 4 3 3 3 T T T T T 4.5 4 3 3 3 T T T T 5 4.5 4 3 3 3 T 6 6 6 5 4.5 4 3 3 3 T 7.5 6 5 4.5 4 3 3 3 DPX 250 ER (25 kA, 36 kA & 60 kA) DPX 160 (25 kA, 36 kA & 60 kA) 125 T T T T 5 4.5 4 3 3 3 T T T T T 4.5 4 3 3 3 T T T T 5 4.5 4 3 3 3 T 6 6 6 5 4.5 4 3 3 3 T 7.5 6 5 4.5 4 3 3 3 2 25 T T T T 40 T T T T 5 4.5 63 T T T T 5 4.5 T T T T T T T T T 3.5 T T T T T 3.5 2 2 T T T T 5 T T T T 5 3.5 T T T T 5 3.5 2 2 T 7.5 7.5 6 T 7.5 7.5 6 5 3.5 T 7.5 7.5 6 5 3.5 2 2 12 7 6 T 7 6 5 3.5 T 7 6 5 3.5 2 2 100 T T T T 5 4.5 4 3 3 3 T T T T T 4 3.5 2.5 2 2 T T T T 5 4 3.5 2.5 2 2 T 7 7 6 5 4 3.5 2.5 2 2 T 7 6 5 4 3.5 2.5 2 2 2 6 5 6 5 4 4 6 5 4 3 3 6 5 4 3 3 2 2 T 7.5 6 5 4.5 4 3 3 3 T 7.5 6 5 4.5 4 3 3 3 2 12 7 6 12 7 6 5 3.5 12 7 6 5 3.5 2 2 12 7 6 5 4 3.5 2.5 2 2 6 5 6 5 4 4 6 5 4 3 3 6 5 4 3 3 2 2 13 7.5 6 5 4.5 4 3 3 3 13 7.5 6 5 4.5 4 3 3 3 2 12 7 6 12 7 6 5 3.5 T 7.5 6 5 4.5 4 3 T 7.5 6 5 4.5 4 3 3 3 7 6 7 6 5 3.5 7 6 5 3.5 2 2 7 6 7 6 5 3.5 7.5 6 5 4.5 4 3 7 6 5 4 3.5 2.5 2 2 7.5 6 5 4.5 4 3 3 3 160 T T T T T T T T 5.5 5 T T T T T T T T T T T T T T T T T T 5.5 5 T T T T T 8.5 7 6 5.5 5 T T T 12 8.5 7 6 5.5 5 5 4 2 4 3 1.5 T T 18 12 8.5 7 6 5.5 5 5 4 2 T T T 18 8.5 7 6 5.5 5 4 3 1.5 T 18 12 8.5 7 6 5.5 5 T T 18 8.5 7 6 5.5 5 100 T T T T 8 6 5 4 4 3 T T T T T T 4 3.5 3 2 T T T T T 5 4 3.5 3 2 T T T T 8 6 5 4 4 3 T T 8 6 5 4 3.5 3 2 T T 8 6 5 4 3.5 3 2 T T 6 6 5.5 4.5 4.5 3.5 3.5 T 8 6 5 4 3.5 3 2 T 6 6 5.5 4.5 4.5 3.5 3.5 160 T T T T T T T T 5.5 5 T T T T T T T T T T T T T T T T T T 5.5 5 T T T T T 8.5 7 6 5.5 5 T T T T 8.5 7 6 5.5 5 5 4 2 4 3 1.5 T T T T 8.5 7 6 5.5 5 5 4 2 T T T T 8.5 7 6 5.5 5 4 3 1.5 T T T 8.5 7 6 5.5 5 T T T 8.5 7 6 5.5 5 250 T T T T T T T T T 6 T T T T T T T T T T T T T T T T T T T 5 T T T T T T T T 7 6 T T T T T T T 7 5 5 4 3 5 4 2 T T T T T T T 7 5 5 4 3 T T T T T T T T 6 5 4 2 T T T T T T 7 5 T T T T T T T 6 DPX 250 / DPXH 250 40 T 5 4 4 4 3 63 T 5 4 4 4 3 2 2 T T 4 4 4 3 T T 4 4 4 3 2 2 T 5 4 4 4 3 T 5 4 4 4 3 2 2 6 5 4 4 4 3 6 5 4 4 4 3 2 2 6 5 4 4 3 6 5 4 4 3 2 2 6 5 4 4 3 6 5 4 4 3 2 2 6 5 4 4 6 5 4 4 3 2 5 4 4 3 5 4 4 3 2 2 5 4 4 5 4 4 3 2 thermal magnetic 100 160 T T T T T T T T T T T T 5 T 5 T 4 T 4 T T T T T T T T T T T T T T T T T 4 T 4 T T T T T T T T T T T T T 5 T 5 T 4 T 4 T T T T T T T T T 8 T 6 T 5 T 5 T 4 8 4 8 T T 15 T 10 T 8 T 6 T 5 T 5 10 4 8 4 8 8 6 3 8 6 3 T T 15 T 10 T 8 T 6 T 5 T 5 10 4 8 4 8 8 6 3 T T T T 10 T 8 T 6 T 5 T 5 10 4 8 4 8 8 6 3 15 T 10 T 8 T 6 T 5 T 5 10 4 8 4 8 T T 10 T 8 T 6 T 5 T 5 10 4 8 4 8 DPX 630/1600 DMX3 2500/4000 DPX 250 / DPXH 250 250 T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T 8 T T 7 T T T T T T T T T T T 8 T T T T T T T T T T T 7 T T T T T T T T T T T T T T T T 40 T T T T 5 4 T T T T T 4 T T T T 5 4 T T 8 6 5 4 T 10 7 5 4 T 10 7 5 4 T 10 7 5 10 7 5 4 10 7 5 electronic 100 160 T T T T T T T T T T T T 5 T 5 T 4 T 4 T T T T T T T T T T T T T T T T T 4 T 4 T T T T T T T T T T T T T 5 T 5 T 4 T 4 T T T T T T T T T 8 T 6 T 5 T 5 T 4 8 4 8 T T 15 T 10 T 8 T 6 T 5 T 5 10 4 8 4 8 8 6 3 8 6 3 T T 15 T 10 T 8 T 6 T 5 T 5 10 4 8 4 8 8 6 3 T T 15 T 10 T 8 T 6 T 5 T 5 10 4 8 4 8 8 6 3 15 T 10 T 8 T 6 T 5 T 5 10 4 8 4 8 15 T 10 T 8 T 6 T 5 T 5 10 4 8 4 8 250 T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T 8 T T 7 T T T T T T T T T T T 8 T T T T T T T T T T T 7 T T T T T T T T T T T T T T T T 160 to 4000 T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T T ■ Upstream fuse gG type MCCBs downstream 250 A DPX 125 7500 400 A DPX 160 10000 DPX 250 ER 10000 DPX 250 10000 DPX 630 1000 A 50000 Legrand_DPX_MCCBs_40-1600A_en_0712.pdf T: total selectivity, up to downstream circuit breaker breaking capacity according to IEC 60947-2 Helsinki St. Petersburg Moscow tel. +358 9 540 4940 automation@klinkmann.fi tel. +7 812 327 3752 klinkmann@klinkmann.spb.ru tel. +7 495 641 1616 moscow@klinkmann.spb.ru Yekaterinburg Samara Кiev tel. +7 343 287 19 19 yekaterinburg@klinkmann.spb.ru tel. +7 846 273 95 85 samara@klinkmann.spb.ru tel. +38 044 495 33 40 klinkmann@klinkmann.kiev.ua Riga Vilnius Tallinn Мinsk tel. +371 6738 1617 klinkmann@klinkmann.lv tel. +370 5 215 1646 post@klinkmann.lt tel. +372 668 4500 klinkmann.est@klinkmann.ee tel. +375 17 200 0876 minsk@klinkmann.com www.klinkmann.com 150