Leksell® Neuro Generator Overview One for all All the functionality you need Leksell® Neuro Generator now adds pulsed RF to the wide range of available functions. It offers very high functionality in a compact package that is easy to learn and effective to work with. One Fully Integrated System Together with customized electrodes and cannulas, Leksell® Neuro Generator provides excellent flexibility and versatility. It is the only neurogenerator to be fully integrated with Leksell Sterotactic System®. Versatility Delivered Leksell Neuro Generator is a complete system designed for a wide range of treatment techniques and therapies, including: • Impedance measurement • Macro stimulation • Continuous RF treatment • Pulsed RF treatment • Stereotactic brain lesioning • Bipolar coagulation Unique Capabilities • Th e Active Tissue Characterization feature further improves performance for delicate treatment. The instrument automatically tests specific tissue response to small amounts of current before each treatment. It then optimizes parameters accordingly, enabling safer treatment and a better outcome for the patient. • The remote control is another unique feature. Used for macro stimulation, it allows the clinician to closely follow the patient’s reactions. • Leksell Neuro Generator can be safely and effectively operated while fully draped under full sterile conditions. Easy to Understand, Easy to Use Leksell Neuro Generator offers a user-friendly interface with multifunctional keys, compact size and remotely controlled features, allowing the clinician to work closer to the patient. All stimulation parameters are continuously monitored and adjustable. The temperature bar graph shows both set and current temperature, as well as rate of change. The System that Matters – for Patients Leksell Neuro Generator is a comprehensive solution that aids neurosurgeons and anesthesiologists in improving safety and quality of life for patients through a unique range of advanced features. Proven Technology Leksell Neuro Generator is based on well-proven technology. It offers a number of important safety features, such as the unique Active Tissue Characterization, and protection against overload and overheating. Thermocouple sensor-controlled electrodes provide additional protection. Specific electrodes for each particular task A wide range of specially designed monopolar and bipolar electrodes are available for applications such as impedance measuring, macro stimulation, brain lesioning and pulsed RF treatment. The brain lesion electrodes are specifically designed to work smoothly with the Leksell Stereotactic System®. Brain Lesion Electrodes Easier DBS electrode implantation Elekta MicroDrive Bipolar Macro Electrode is used for target localization, verification and lesioning. It is designed for use with Elekta MicroDrive™ when determining the correct target for DBS electrode implantation and lesioning. When performing lesioning, the electrode is supported by the high accuracy of Elekta MicroDrive™. Accurate Lesioning and Stimulation Brain lesion electrodes are intended for impedance measurement, macro stimulation and lesioning. They are used for target localization and verification, as well as for stereotactic brain lesioning. The electrodes are either monopolar, bipolar or dual monopolar. All are using Leksell Stereotactic System®. They have integrated thermocouplecontrolled temperature measurement and are fully steam autoclavable and reusable. The wide offering of electrodes enables the most optimal treatment for each patient. Electrodes and Cannulas for RF Treatment Specialized Electrodes for Safe Lesioning The customized DREZ electrode has a specialized design that ensures only the tip of the electrode penetrates the target. The depth of the penetration is assured by the shoulder of the electrode insulation, which stops the electrode from penetrating deeper than 2 mm. Cannulas for Easy Access The cannulas are designed for use with the customized thin RF electrodes. They are straight or curved, equipped with a sharp or blunt tip, and provided in many different tip lengths. The cannulas offer easy access and guidance through the tissue and are intended for single use. Optimal RF Lesioning or Pulsed RF Treatment These thin electrodes are specifically designed for use with dedicated subcutaneous cannulas. They are available in three lengths with a wide range of cannulas to meet various needs. All have integrated thermocouplecontrolled temperature measurement and are fully steam autoclavable and reusable. Why Leksell Neuro Generator? One system of connected components that meets all functional needs Proven long-term reliability Total integration with Leksell Stereotactic System® Flexible and versatile Effective operation under sterile conditions Wide range of electrodes and cannulas Technical data Frequency Voltage Pulse duration Pulsed RF RF Voltage Rate Duration Time range Temperature range Impedance monitoring Impedance Impedance reading Coagulation unit Bipolar coagulation Physical characteristics Mains Dimensions Weight Remote control Accessories Electrodes Foot switch Max 30W. Automatic temperature control during lesioning 512kHz 0–100s 0–100°C Constant current 0.03 –15mA Manual or automatic increase during stimulation 3–200Hz Automatically controlled with upper limit 35V 0.05– 2.5ms for 3–10Hz 0.05–1.2ms for 20–200Hz Frequency 512kHz 0-55V 1, 2, 3, 4, 5, 6, 7, 8Hz 20, 32ms 0-200s 40-64°C 20–1000Ohm Digital with tone Max 30W for coagulation using forceps. Foot switch 230, 115, 100V 320(W) x 205(D) x 130(H)mm 5 kg Handheld for stimulation Brain lesion electrodes: Monopolar, Bipolar and Dual (two parallel monopolar electrodes). Reusable Pain Electrodes and disposable cannulas Foot switch for coagulation The product in this brochure may not be cleared for sales in all markets. Please contact your Elekta sales representative for more information. www.elekta.com Human Care Makes the Future Possible Corporate Head Office: Regional Sales, Marketing and Service: Elekta AB (publ) Box 7593, SE-103 93 Stockholm, Sweden Tel +46 8 587 254 00 Fax +46 8 587 255 00 info@elekta.com North America Tel +1 770 300 9725 Fax +1 770 448 6338 info.america@elekta.com Europe, Middle East, Africa, Eastern Europe, Latin America Tel +46 8 587 254 00 Fax +46 8 587 255 00 info.europe@elekta.com Asia Pacific Tel +852 2891 2208 Fax +852 2575 7133 info.asia@elekta.com Document no. 1500931.00 OCT2013 ©2013 Elekta. All mentioned trademarks and registered trademarks are the property of the Elekta Group. All rights reserved. No part of this document may be reproduced in any form without written permission from the copyright holder. Specifications subject to change without notice. Lesion Power RF frequency Time range Temperature range Stimulation Current