Occupancy Sensors and Lighting Control Products

advertisement
SECTION
Occupancy Sensors & Lighting Control Products
Infrared Occupancy Sensors
Commercial Grade Occupancy Sensor Features and Types
Commercial Grade
Leviton provides a variety of spacemonitoring Occupancy Sensor
Lighting Controls for virtually any
room, space, facility, home or office.
Wall or ceiling, passive infrared or
ultrasonic, end users will benefit from
Leviton's Occupancy Sensors as a
direct result of their energy efficiency
and obvious cost-effectiveness.
Passive Infrared (PIR)
detection technology
to monitor room for
occupancy
Sensor automatically
sends signal to switch
lights on and keep them on
when room is occupied
and activity detected
1
180° field of view, 2,100
square feet of coverage
Adjustable delayed off-time
(30 seconds 20 minutes)
Features and Benefits - ODS15-ID
• 180° field of view, covers approximately
2100 square feet
• Selectable base time-delay interval from
30 seconds to 20 minutes
• Self-adjusting delayed off time interval
compensates for real time occupancy
patterns, preventing unnecessary on/off
switching
• Can be used with incandescent or
fluorescent lighting
• Motion-activated; infrared sensing
technology turns lights ON when room is
occupied and OFF when unoccupied
• Replaces standard switches in existing
wallboxes
• Ambient light override keeps lights off
when there’s plenty of sunlight
• Push-button manual override allows
controls to be used like standard ON/OFF
switches; manual-ON/Auto-OFF mode
• “Walk-Through” feature shuts off lights
after 21/2 minutes rather than an extended
period
• Compatible with Decora designer-styled
devices
• Backed by a Limited Five-Year Warranty
LED indicator
light flashes
when sensor
detects motion
Ambient light
override prevents
the sensor from
switching lights on
when there is
ample natural
sunlight
ODS15 SERIES
To learn more about Leviton's Architectural Lighting Control
Systems, Box-Mounted Dimmers, Fan Speed Controls, Timers,
and Home Automation Products request a Lighting Controls
Product Catalog.
Versatile Occupancy Sensor Lighting Controls for Cost-Effective Energy Savings
Dual-Relay
Decora® Wall
Switch Infrared
Occupancy
Sensor
PAGE N3
Controls two separate lighting loads
from a single unit.
Features self-adjusting technology for
maximum performance.
Self-Contained Ceiling
Mount PIR Occupancy Sensor
Contains sensor and switching relay;
360° field of view; adjustable delayed
off time of 20 seconds to 15 minutes.
Combines infrared and ultrasonic
technology for highly accurate
monitoring. 360°, 2000 sq. ft
coverage.
Infrared HighBay Wall-Mount
Occupancy
Sensor
Ideal for ware
house aisles,
hallways,
stairways and
other long,
narrow spaces.
Combines infrared
and ultrasonic
technology for highly
accurate monitoring.
110°, 1200 sq. ft
coverage.
PAGE N8
Multi-Technology CeilingMount Occupancy Sensor
PAGES N5-N7
PAGE N4
MultiTechnology
Wall-Mount
Occupancy
Sensor
N
Fresnel lenses for “small motion” detection to
monitor movement in room
PAGE N9
To learn more about Leviton devices or for answers to technical questions call our Techline at
Outdoor Motion Sensor
Ideal for commercial/industrial
settings, with temperature compensation to ensure performance in all
weather conditions.
PAGE N11
1-800-824-3005 or visit us at:
www.leviton.com
The Centura™ System
Centura™ Fluorescent Management System
SPECIFICATIONS & FEATURES
COMMERCIAL GRADE
CENTURA™ FLUORESCENT
MANAGEMENT SYSTEM
• Ideal for commercial spaces and individual offices.
STANDARDS & CERTIFICATIONS
UL
Listed
CSA
Certified
• All functions conveniently accessed through Entry Station Wall Switch – Users do not have to
make adjustments at ceiling unit.
• Dimming Power Pack provides low-voltage power supply for Entry Stations, Photocell and
Occupancy Sensors.
• Photocell provides energy savings through Daylight Harvesting
technology.
• Use with Leviton Occupancy Sensors for increased energy savings: Lights turn ON automatically to programmed levels when personnel enter area; OFF automatically when area becomes
vacant.
• Modular system design expands energy saving options with an interface for building emergency systems, load shedding programs and time clock systems.
• Dimming Power Pack mounts in standard box. Wall Switch Entry Stations mount in standard
single-gang switch box 4"x4" square.
CN100-0D0
Centura™ Fluorescent Energy Management System
CN221-00C
Leviton's new Centura™, a modular lighting control system for dimming fluorescent ballasts (Advance Mark VII™, 0-10V and Osram Sylvania Quicktronic Helios,
brings increased energy savings to commercial spaces. Using a technique known as “daylight harvesting”, Centura™ factors in the available daylight for the precise
control of fluorescent light levels to achieve optimum comfort and energy efficiency.
COLOR
CATALOG
NUMBER
DESCRIPTION
RATING
Commercial Grade Centura™ Fluorescent Energy Management System
Centura™ Dimming Power Pack—ON/OFF and DIM/BRIGHT
CN100
control of dimming fluorescent ballasts. Responds to Entry
Station, Occupancy Sensor and Photocell input and provides
+24 VDC power supply for these devices. Programmed via
Entry Station. Secondary relay sends control signals to HVAC
system. LED's indicate operation mode.
Gray Metallic
CN200-00C 5 Button Dimming Entry Station—This entry station allows
manual control of the dimming power pack. Its buttons are On,
Max, Bright, Dim, and Off. The buttons are illuminated when
selected. Also, it has an infrared port to be controlled by a
matching remote control and has the ability to program the
Max, Min., and Daylight Maintain levels.
White
CN220-00C 2 Button Entry Station—This entry station allows manual control of the dimming power pack for applications for non-dim
(Ivory color change
loads. It is the Mural™ (MS) style. Its buttons are On and Off.
2400VA @ 120V AC 60Hz,
5500VA @ 277V AC 60Hz
For use with Advance Mark VII™,
0-10V and Osram Sylvania Quicktronic
Helios and comparable ballasts only
Clear
(Ivory color change
kit included)
No load rating, for use with Centura
Dimming Power Pack only
No load rating, for use with Centura
Dimming Power Pack only
kit included)
CN221-00C Centura™ Entry Station Wall Switch—Decora-style rocker for
ON/OFF switching with built-in arrow-shaped rocker for
(Ivory color change
DIM/BRIGHT control. LED display indicates selected brightkit included)
ness level. Programs all energy management functions—back
of wallplate provides instruction label that lines up with LED’s
to facilitate programming.
Centura
Photocell—Detects available light levels for “Daylight
White
ODC0P
Harvesting”. Allows Centura™ system to maintain a programmed light level by constantly adjusting fluorescent light
output to compensate for available daylight.
White
NE100-00C Smart Jack—The Smart Jack makes all the above mentioned
items networkable through a PC or a remote PC via an ether(Ivory color change
net link. The Smart Jack will also come with the computer softkit included)
ware for the server and client applications.
Black
NE200-E Hand-Held Remote Control—The remote control will match
the functionality of the 5 Button Entry Station
White
OCCUPANCY
SENSOR
CENTURA™ ENERGY MANAGEMENT
SYSTEM ESSENTIAL COMPONENTS
Phase
Neutral
Dimming Power Pack
PHOTOCELL
Cat. No. ODC0P
No load rating, for use with Centura
Dimming Power Pack only
No load rating, for use with Centura
Dimming Power Pack only
No load rating, for use with Centura
Dimming Power Pack only
–
ENTRY STATION
Cat. No. CN221
Commercial Grade Occupancy Sensors - The Centura™ System
• Reduces eyestrain and fatigue from glare, increasing comfort and
productivity.
POWER (+24V)
GROUND
OCCUPANY
CAN_H
CAN_L
PHOTCELL
Cat. No. CN100
DIM
RETURN
HVAC NO
HVAC NC
HVAC COMM.
N
HVAC
Interface
0-10V DC Ballast
To learn more about Leviton devices or for answers to technical questions call our Techline at
1-800-824-3005 or visit us at:
www.leviton.com
2
Infrared Occupancy Sensors
Commercial Grade
DECORA® WALL SWITCH
INFRARED OCCUPANCY
SENSOR (ODS15-ID)
• For use in small offices,
conference rooms, class rooms,
stock rooms, lounges, restrooms,
warehouses & commercial areas.
• Automatic “Walk-Through”
sensing increases energy
savings by shutting lights within
2 1⁄2 minutes after momentary
occupancy.
Commercial Grade Wall Switches
• Self-adjusting delayed OFF-time
interval compensates for
real-time occupancy patterns,
preventing unnecessary ON/OFF
switching.
• 180° field of view, 2100 sq. ft. of
coverage.
SPECIFICATIONS & FEATURES
DUAL-RELAY DECORA
WALL SWITCH INFRARED
OCCUPANCY SENSOR (ODS0D-ID)
• Ideal for class & conference rooms.
• Automatic “Walk Through” sensing.
• Automatic switching for 2 separate
banks of fluorescent, incandescent,
or low-voltage lighting from a single
unit.
• Self-adjusting delayed OFF-time
interval compensates for real-time
occupancy patterns, preventing
unnecessary ON/OFF switching.
• 180° field of view, 2100 sq. ft. of
coverage.
• Ambient light override prevents
these devices from switching lights
ON when there is ample natural
sunlight.
• Push-button manual override is
used to turn lights ON at any time,
regardless of the override setting.
STANDARDS & CERTIFICATIONS
UL
CSA
NOM
Listed
C22.2 No. 205
WALL SWITCH INFRARED
OCCUPANCY SENSOR
(ODS10-ID)
CUL/US
Certified
• For use in enclosed offices,
storage rooms, copier rooms &
closets.
ODSOD Only
#E118904
STORAGE TEMP.
OPERATING TEMP.
-10C to 85C
0C to 50C
• 180° field of view, 2,100 sq. ft.
of coverage.
• Fits in standard wallbox;
gangable.
• Delayed-off time setting (30
seconds – 30 minutes).
• Elegant Decora styling; uses
Decora wallplate.
CATALOG NUMBER
ODS15-IDW
with 80301-W plate
DESCRIPTION
RATING
Commercial Grade Dual-Relay Decora® Wall Switch Infrared Occupancy Sensors
Ivory
White
Gray
Almond
ODS0D-IDI
ODS0D-IDW
ODS0D-IDG
ODS0D-IDA
COLOR
CATALOG NUMBER
Commercial Grade
Ivory
White
Gray
Almond
COLOR
Commercial Grade
Ivory
White
Gray
Almond
Adaptive Dual Relay Occupancy Sensors:
Conference Room Mode Both Primary and
Secondary Relays respond to Ambient
Light Override.
Primary Relay:
Fluorescent: 1200VA @120V, 2700VA @ 277V
Incandescent: 800W @120V
Alternate Setting: Classroom Mode Primary Secondary Relay:
Fluorescent: 800VA @120V, 1200VA 277V
Relay only responds to Ambient Light
Override.
Incandescent: 800W @120V
DESCRIPTION
RATING
Decora® Wall
Switch Infrared Occupancy Sensor (Incandescent and Fluorescent)
ODS10-IDI
Fluorescent: 1200VA @ 120V,
ODS10-IDW
Infrared
2700VA @ 277V
Occupancy Sensors
ODS10-IDG
Incandescent: 800W @ 120V
ODS10-IDA
Motor: 1/4 HP @ 120V
CATALOG NUMBER
DESCRIPTION
RATING
Decora® Wall
Switch Infrared Occupancy Sensor (Incandescent and Fluorescent)
ODS15-IDI
Fluorescent: 1800VA @ 120V,
ODS15-IDW
Adaptive Infrared
4000VA @ 277V
Occupancy Sensors
ODS15-IDG
Incandescent: 1800W @ 120V
ODS15-IDA
Motor: 1/4 HP @ 120V
1.75 (44.4 mm)
1.30
(33.0 mm)
0.49 (12.6 mm)
2.60 (66.1 mm)
2.61 (66.3 mm)
3
4.06 (103.2 mm)
1.35
(34.3 mm)
N
#057
ENVIRONMENTAL
• One unit can be used for 120V
or 277VAC 60Hz incandescent,
low-voltage and fluorescent
lighting with either magnetic or
electronic ballasts, and motor
loads.
ODS0D-IDW
with 80301-W plate
COLOR
#LR-91148M
ON
OFF
AUTO
BOTTOM
ODS15-ID
To learn more about Leviton devices or for answers to technical questions call our Techline at
1-800-824-3005 or visit us at:
www.leviton.com
Infrared Occupancy Sensors
Commercial Grade
STANDARDS & CERTIFICATIONS
UL
Listed
CSA
Certified
• Ideal for use in storage areas, small bathrooms, copy rooms and a variety of small spaces without wall
switches.
• Full 360° view of a 530 sq. ft. area when surface mounted on standard, 8-foot ceiling.
• Sensor and switching relay combined in a single self-contained unit—No control unit required.
• Ambient light override option prevents lights from turning ON when there is ample natural light.
• Adjustable Delayed-OFF time settings from 20 seconds (for test mode) to 15 minutes.
• Small, unobtrusive self-contained unit: 4.3" (109.2 mm) diameter.
ODC0S-I1W
COLOR
CATALOG NUMBER
DESCRIPTION
Commercial Grade Self-Contained Ceiling-Mount Occupancy Sensors
White
ODC0S-I1W
Self-Contained Ceiling-Mount
(formerly 16786-120)
Infrared Occupancy Sensor
and Switching Relay
COVERAGE
RATING
360°, 530 sq. ft.
Incandescent: 1000W @ 120V
Fluorescent/Inductive:
1000VA @ 120V For 60Hz AC only.
1HP@120V AC
White
ODC0S-I2W
Self-Contained Ceiling-Mount
Infrared Occupancy Sensor
and Switching Relay
360°, 530 sq. ft.
Incandescent: 1000W @ 220V
Fluorescent/Inductive:
500VA @ 220V For 50Hz AC only.
White
ODC0S-I7W
(formerly 16786-277)
Self-Contained Ceiling-Mount
Infrared Occupancy Sensor
and Switching Relay
360°, 530 sq. ft.
Fluorescent/Inductive:
2700VA @ 277V For 60Hz AC only.
White
ODCCG-000
Protective Cage
–
–
2.15 (54.6 mm)
N
4.3 (109.2 mm)
ODC0S-I1W
To learn more about Leviton devices or for answers to technical questions call our Techline at
Commercial Grade Self-Contained Ceiling-Mount Occupancy Sensors
SPECIFICATIONS & FEATURES
COMMERCIAL GRADE
SELF-CONTAINED CEILING-MOUNT
OCCUPANCY SENSORS
• PIR Occupancy Sensor with built-in relay—Separate Power Pack not required.
1-800-824-3005 or visit us at:
www.leviton.com
4
Multi-Tech. Occupancy Sensors
Commercial Grade
SPECIFICATIONS & FEATURES
MULTI-TECH CEILING MOUNT
OCCUPANCY SENSORS
STANDARDS & CERTIFICATIONS
OPTIONAL
PERFORMANCE FEATURES
CUL/US
Certified
Commercial Grade Ceiling Mount Occupancy Sensors
For Models with -MRW Suffix
ODC20-M0W
Multi-Technology Ceiling-Mount Occupancy Sensor (For use with Leviton Power Pack)
Advanced motion sensors combine infrared and ultrasonic technology for highly accurate monitoring without false triggering. All-digital
self-adjusting technology provides “Install and Forget” solution for automatic lighting control. Low-voltage wiring is used to connect Leviton
Occupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately). See page N10 for Power Pack information.
COLOR
CATALOG NUMBER
DESCRIPTION
COVERAGE
OPERATING FREQUENCY
180°, 500 sq. ft.
40kHz
180°, 500 sq. ft.
40kHz
Multi-Tech Ceiling-Mount
Occupancy Sensor
Multi-Tech Ceiling-Mount
Occupancy Sensor with Ambient
Light Override & Secondary Relay
180°, 1000 sq. ft.
32kHz
180°, 1000 sq. ft.
32kHz
Multi-Tech Ceiling-Mount
Occupancy Sensor
Multi-Tech Ceiling-Mount
Occupancy Sensor with Ambient
Light Override & Secondary Relay
360°, 2000 sq. ft.
32kHz
360°, 2000 sq. ft.
32kHz
Commercial Grade Ceiling-Mount Occupancy Sensors
White
ODC05-M0W
Multi-Tech Ceiling-Mount
Occupancy Sensor
Multi-Tech Ceiling-Mount
White
ODC05-MRW
Occupancy Sensor with Ambient
Light Override & Secondary Relay
White
ODC10-M0W
White
ODC10-MRW
White
ODC20-M0W
White
ODC20-MRW
White
ODCRA-000
Hard-Ceiling Raceway Adapter Kit
–
–
White
ODCCG-000
Protective Cage for Ceiling-Mount
Occupancy Sensors
–
–
1.40
(35.6 mm)
N
5
• For office areas, warehouse and storage facilities, and public areas in
• Ambient light override option
commercial facilities.
prevents lights from turning
ON when there is ample nat• Ultrasonic sensing with Passive Infrared (PIR) sensing.
ural light.
• Self-adjusting settings continuously analyze and adjust infrared sensitivity, timer operation, and air current compensation for reliable, long• Secondary Relay — Singleterm performance.
Pole Double-Throw (SPDT),
rated 500 mA @ 24V AC/DC,
• Built-in Circadian Calendar—Provides 4-week learning period to estabthree-wire isolated relay.
lish trends that serve as the basis for automatic operation. In peak
occupancy periods the sensor remains in high-sensitivity mode and in
•
Secondary
Relay can be used
low occupancy periods it switches to economy mode.
to send control signals to
• Manual Delayed-OFF time settings of 8, 16, & 32 minutes.
HVAC systems based on
• Self-Adjusting Delayed-OFF time interval settings for 8 to 100 minutes.
occupancy detection.
• Preserves all automatic and manual settings during power outages.
• Choice of coverage patterns to suits a variety of applications.
• Small, unobtrusive size (4.5" diameter) blends in with any décor.
• Hard-Ceiling Raceway Adapter Kit (optional) provides complete solution for mounting occupancy sensors to hard ceilings. Two-piece kit
contains Adapter Base and “rotate and lock” Adapter Plate for attaching
Sensor. Compatible with most standard surface-mounting raceways;
also suitable for mounting Sensors to standard octagonal J box.
ø 4.53
(115.1 mm)
1.40
(35.6 mm)
ODC05-M, ODC10-M
To learn more about Leviton devices or for answers to technical questions call our Techline at
ø 4.53
(115.1 mm)
ODC20-M
1-800-824-3005 or visit us at:
www.leviton.com
Ultrasonic Occupancy Sensors
Commercial Grade
SPECIFICATIONS & FEATURES
ULTRASONIC CEILING MOUNT
OCCUPANCY SENSORS
STANDARDS & CERTIFICATIONS
OPTIONAL
PERFORMANCE FEATURES
CUL/US
Certified
For Models with -URW Suffix
ODC10-U0W
Ultrasonic Ceiling-Mount Occupancy Sensor (For use with Leviton Power Pack)
Advanced Ultrasonic sensing technology for highly accurate monitoring with excellent immunity to air currents and other interference. All-digital
self-adjusting technology provides “Install and Forget” solution for automatic lighting control. Low-voltage wiring is used to connect Leviton
Occupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately). See page N10 for Power Pack information.
COLOR
CATALOG NUMBER
DESCRIPTION
COVERAGE
Commercial Grade Ultrasonic Ceiling-Mount Occupancy Sensors
White
ODC05-U0W
Ultrasonic Ceiling-Mount
Occupancy Sensor
OPERATING FREQUENCY
180°, 500 sq. ft.
40kHz
White
ODC05-URW
Ultrasonic Ceiling-Mount
Occupancy Sensor with Ambient
Light Override & Secondary Relay
180°, 500 sq. ft.
40kHz
White
ODC10-U0W
Ultrasonic Ceiling-Mount
Occupancy Sensor
180°, 1000 sq. ft.
32kHz
White
ODC10-URW
Ultrasonic Ceiling-Mount
Occupancy Sensor with Ambient
Light Override & Secondary Relay
180°, 1000 sq. ft.
32kHz
White
ODC20-U0W
Ultrasonic Ceiling-Mount
Occupancy Sensor
360°, 2000 sq. ft.
32kHz
White
ODC20-URW
Ultrasonic Ceiling-Mount
Occupancy Sensor with Ambient
Light Override & Secondary Relay
360°, 2000 sq. ft.
32kHz
White
ODCRA-000
Hard-Ceiling Raceway Adapter Kit
–
–
White
ODCCG-000
Protective Cage for Ceiling-Mount
Occupancy Sensors
–
–
1.40
(35.6 mm)
ø 4.53
(115.1 mm)
1.40
(35.6 mm)
ODC05-U, ODC10-U
To learn more about Leviton devices or for answers to technical questions call our Techline at
Commercial Grade Ceiling-Mount Occupancy Sensors
• Ideal for restrooms, office areas with cubicles, general work space,
• Ambient light override option
warehouse and storage facilities, cafeterias and public areas in comprevents lights from turning
mercial facilities.
ON when there is ample natural light.
• Ultrasonic sensing for maximum range and sensitivity.
• Self-adjusting settings continuously analyze and adjust sensitivity, timer • Secondary Relay — SinglePole Double-Throw (SPDT),
operation, and air current compensation.
rated 500 mA @ 24V AC/DC,
• Automatic dual-mode operation adjusts to either economy or high-senthree-wire isolated relay.
sitivity mode based on actual occupancy patterns.
• Secondary Relay can be used
• Built-in Circadian Calendar—Provides 4-week learning period to estabto send control signals to
lish trends that serve as the basis for automatic operation. In peak
HVAC systems based on
occupancy periods the sensor remains in high-sensitivity mode and in
occupancy detection.
low occupancy periods it switches to economy mode.
• Manual Delayed-OFF time settings of 8, 16, & 32 minutes.
• Choice of coverage patterns to suits a variety of applications.
• Fast, simple installation using 3 color-coded low-voltage wires and a
single mounting post.
• Hard-Ceiling Raceway Adapter Kit (optional) provides complete solution for mounting occupancy sensors to hard ceil “rotate and lock”
Adapter Plate for attaching Sensor. Compatible with most standard surface-mounting raceways; also suitable for mounting Sensors to standard octagonal J box.
ø 4.53
(115.1 mm)
N
ODC20-U
1-800-824-3005 or visit us at:
www.leviton.com
6
Infrared Occupancy Sensors
Commercial Grade
SPECIFICATIONS & FEATURES
INFRARED CEILING MOUNT
OCCUPANCY SENSORS
STANDARDS & CERTIFICATIONS
OPTIONAL
PERFORMANCE FEATURES
Commercial Grade Ceiling Mount Occupancy Sensors
For Models with -IRW Suffix
7
• Ideal for use in small offices, general work areas, closets, and other
• Ambient light override option
small areas in commercial facilities.
prevents lights from turning
ON when there is ample nat• Self-adjusting settings continuously analyze and adjust infrared sensiural light.
tivity, timer operation, and air current compensation for reliable, longterm performance.
• Secondary Relay — Single• Built-in Circadian Calendar—Provides 4-week learning period to estabPole Double-Throw (SPDT),
lish trends that serve as the basis for automatic operation. In peak
rated 500 mA @ 24V AC/DC,
occupancy periods the sensor remains in high-sensitivity mode and in
three-wire isolated relay.
low occupancy periods it switches to economy mode.
•
Secondary
Relay can be used
• Manual Delayed-OFF time settings of 8, 16, & 32 minutes.
to send control signals to
• Self-Adjusting Delayed-OFF time interval settings for 8 to 100 minutes.
HVAC systems based on
• Preserves all automatic and manual settings during power outages.
occupancy detection.
• Choice of coverage patterns to suits a variety of applications.
• Small, unobtrusive size (4.5" diameter) blends in with any décor.
• Hard-Ceiling Raceway Adapter Kit (optional) provides complete solution for mounting occupancy sensors to hard ceilings. Two-piece kit
contains Adapter Base and “rotate and lock” Adapter Plate for attaching
Sensor. Compatible with most standard surface-mounting raceways;
also suitable for mounting Sensors to standard octagonal J box.
ODC04-I0W
Infrared Ceiling-Mount Occupancy Sensor (For use with Leviton Power Pack)
Includes Advanced Passive Infrared technology for highly accurate monitoring in a variety of commercial applications. All-digital selfadjusting technology provides “Install and Forget” solution for automatic lighting control. Low-voltage wiring is used to connect Leviton
Occupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately). See page N10 for Power Pack information.
COLOR
CATALOG NUMBER
DESCRIPTION
COVERAGE
Commercial Grade Infrared Ceiling-Mount Occupancy Sensors
White
ODC04-I0W
Infrared Ceiling-Mount
Occupancy Sensor
Infrared Ceiling-Mount
White
ODC04-IRW
Occupancy Sensor with Ambient
Light Override & Secondary Relay
White
ODCRA-000
Hard-Ceiling Raceway Adapter Kit
White
ODCCG-000
360°, 450 sq. ft.
360°, 450 sq. ft.
–
Protective Cage for Ceiling-Mount
Occupancy Sensors
1.40
(35.6 mm)
N
CUL/US
Certified
–
ø 4.53
(115.1 mm)
ODC04-I
To learn more about Leviton devices or for answers to technical questions call our Techline at
1-800-824-3005 or visit us at:
www.leviton.com
Multi-Tech. Occupancy Sensors
Commercial Grade
SPECIFICATIONS & FEATURES
MULTI-TECH WALL-MOUNT
OCCUPANCY SENSORS
STANDARDS & CERTIFICATIONS
OPTIONAL
PERFORMANCE FEATURES
CUL/US
Certified
For Models with -MRW Suffix
ODW12-M0W
Multi-Technology Wall-Mount Occupancy Sensor (For use with Leviton Power Pack)
Advanced motion sensors combine infrared and ultrasonic technology for highly accurate monitoring without false triggering. All-digital
self-adjusting technology provides “Install and Forget” solution for automatic lighting control. Low-voltage wiring is used to connect Leviton
Occupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately). See page N10 for Power Pack information.
COLOR
CATALOG NUMBER
DESCRIPTION
COVERAGE
Commercial Grade Multi-Technology Wall-Mount Occupancy Sensor
White
ODW12-M0W
Multi-Tech Wall-Mount
Occupancy Sensor
White
ODW12-MRW
Multi-Tech Wall-Mount
Occupancy Sensor with Ambient
Light Override & Secondary Relay
OPERATING FREQUENCY
110°, 1200 sq. ft.
32kHz
110°, 1200 sq. ft.
32kHz
5.29 (134.4 mm)
6.58 (167.1 mm)
ø 3.63
(92.2 mm)
3.72
(94.5 mm)
Commercial Grade Multi-Tech Wall-Mount Occupancy Sensors
• Ideal for conference rooms, stair-wells, open areas, storage rooms and • Ambient light override option
classrooms. Also ideal for corner mounting in a variety of applications.
prevents lights from turning
ON when there is ample nat• Ultrasonic sensing for maximum range and sensitivity combined with
ural light.
Passive Infrared (PIR) sensing to prevent false triggering from air
conditioning and corridor activity.
• Secondary Relay—SinglePole Double-Throw (SPDT),
• Adjustable swivel neck rotates 80° vertically and 60° horizontally— Can
rated 500 mA @ 24V AC/DC,
be used for ceiling or wall mounting.
three-wire isolated relay.
• Self-adjusting settings continuously analyze and adjust sensitivity, timer
• Secondary Relay can be used
operation, and air current compensation.
to send control signals to
• Automatic dual-mode operation adjusts to either economy or high-senHVAC systems based on
sitivity mode based on actual occupancy patterns.
occupancy detection.
• Built-in Circadian Calendar—Provides 4-week learning period to establish trends that serve as the basis for automatic operation. In peak
occupancy periods the sensor remains in high-sensitivity mode and in
low occupancy periods it switches to economy mode.
• Manual Delayed-OFF time settings of 8, 16, & 32 minutes.
• Self-Adjusting Delayed-OFF time interval settings for 4 to 100 minutes.
• Non-volatile memory preserves all automatic & manual settings during
power outages.
• Fast, simple installation using 3 color-coded low-voltage wires and a
single mounting post.
N
2.73
(69.3 mm)
ODW12-M
To learn more about Leviton devices or for answers to technical questions call our Techline at
1-800-824-3005 or visit us at:
www.leviton.com
8
Infrared Occupancy Sensors
Commercial Grade
SPECIFICATIONS & FEATURES
INFRARED WALL MOUNT
OCCUPANCY SENSORS
STANDARDS & CERTIFICATIONS
OPTIONAL
PERFORMANCE FEATURES
CUL/US
Certified
N
9
• ODWWV-I: Ideal for rooms with pendant fixtures. Also ideal for corner
• Ambient light override option
mounting in a variety of applications.
prevents lights from turning
ON when there is ample nat• ODWHB-I: Ideal for monitoring long, narrow spaces. Also ideal for corural light.
ner mounting in a variety of applications.
• Self-adjusting settings continuously analyze and adjust infrared sensi- • Secondary Relay — Singletivity, timer operation, and air current compensation.
Pole Double-Throw (SPDT),
rated 500 mA @ 24V AC/DC,
• Adjustable swivel neck rotates 80° vertically and 60° horizontally—Can
three-wire isolated relay.
be used for ceiling or wall mounting.
• Automatic dual-mode operation adjusts to either economy or high-sen- • Secondary Relay can be used
sitivity mode based on actual occupancy patterns for maximum energy
to send control signals to
savings.
HVAC systems based on
• Built-in Circadian Calendar—Provides 4-week learning period where
occupancy detection.
sensor establishes trends that serve as the basis for automatic operation.
• Manual Delayed-OFF time settings with 8-second test mode.
• Self-Adjusting Delayed-OFF time interval settings for 4 to 100 minutes.
• Non-volatile memory preserves all automatic and manual settings during power outages.
• Fast, simple installation using 3 color-coded low-voltage wires and a
single mounting post.
ODWWV-I0W
Infrared Wide-View and High-Bay Wall Mount Occupancy Sensors (For use with Leviton Power Pack)
Includes Advanced Passive Infrared technology for highly accurate monitoring in a variety of commercial applications. All-digital selfadjusting technology provides “Install and Forget” solution for automatic lighting control. Low-voltage wiring is used to connect Leviton
Occupancy Sensors to Cat. No. ODP20 Power Pack (purchased separately). See page N10 for Power Pack information.
COLOR
CATALOG NUMBER
DESCRIPTION
COVERAGE
Commercial Grade Infrared Wide-View Occupancy Sensors
White
ODWWV-I0W
Infrared Wide-View Wall-Mount
Occupancy Sensor
Infrared Wide-View Wall-Mount
White
ODWWV-IRW
Occupancy Sensor with Ambient
Light Override & Secondary Relay
Commercial Grade Infrared High-Bay Occupancy Sensors
White
ODWHB-I0W
Infrared High-Bay Wall-Mount
Occupancy Sensor
Infrared High-Bay Wall-Mount
White
ODWHB-IRW
Occupancy Sensor with Ambient
Light Override & Secondary Relay
110°, 2500 sq. ft.
110°, 2500 sq. ft.
120 ft, 14 ft. wide
@ 30 ft. height
120 ft, 14 ft. wide
@ 30 ft. height
6.58 (167.1 mm)
ø 3.63
(92.2 mm)
5.29 (134.4 mm)
Commercial Grade Wide-View and High-Bay, Wall Mount Sensors
For Models with -IRW Suffix
3.72
(94.5 mm)
2.73
(69.3 mm)
ODWWV-I, ODWHB-I
To learn more about Leviton devices or for answers to technical questions call our Techline at
1-800-824-3005 or visit us at:
www.leviton.com
Power Packs
Commercial Grade
SPECIFICATIONS & FEATURES
POWER PACK
ADD-A-RELAY
CUL/US
Certified
NIPPLE ADAPTER
• Expands Power Pack load capacity • Simplifies the connection of
by functioning as a supplementary
any OD-series Occupancy
relay.
Sensor to the low-voltage side
of a Power Pack mounted
• Provides ability to switch loads in
inside a fluorescent ballast
different voltage systems (For
cavity.
example, switching 120V incandescent loads in a 277V fluorescent
• 1/2" conduit lock nut included.
system and vice versa).
• Compatible with electronic ballasts.
• Same compact size and mounting
features as Power Pack.
ODP20
Power Packs for Occupancy Sensors (For use with Leviton Occupancy Sensors listed on pages N5–N9)
Leviton Power Pack units contain both a 24V DC power supply for Occupancy Sensors and a 13 Amp relay for switching incandescent or ballast lighting loads. AddA-Relay units can be used to expand the control capability. Compact, lightweight Power Pack and Add-A-Relay Units are easily mounted in a junction box knock-out
hole.
DESCRIPTION
CATALOG
NUMBER
POWER
INPUT
RELAY
RATING
CONTROL
INPUT
POWER SUPPLY
OUTPUT
5mA, 24V DC
100mA, 24V DC
Commercial Grade Power Packs for Occupancy Sensors
Black, Power Pack, 120V
ODP20-010
120V AC 60Hz
13 Amps Incandescent
20 A mps Fluorescent
Black, Power Pack, 230V
ODP20-020
230V AC 50 & 60Hz 20 Amps Fluorescent
5mA, 24V DC
100mA, 24V DC
Black, Power Pack, 277V
ODP20-070
277V AC 60Hz
20 Amps Fluorescent
5mA, 24V DC
100mA, 24V DC
Black, Power Pack, 347V
ODP15-030
347V AC 60Hz
15 Amps Fluorescent
5mA, 24V DC
100mA, 24V DC
Black, Add-A-Relay Unit
ODA13-000
–
5mA, 24V DC
–
–
DESCRIPTION
CATALOG NUMBER
Commercial Grade Power Pack Adapter
Low-Voltage Nipple Adapter with 1/2" Lock Nut
for Power Pack and Add-A-Relay units
ODPNA
Power Pack Capacity Guide
One Leviton Power Pack will supply power for a combination of up to 3 devices: 3 sensors (Multi-Tech, PIR or Ultrasonic), 2 sensors and 1 Add-A Relay, 1 sensor and
2 Add-A-Relays, or any combination listed in the chart below.
NUMBER OF OCCUPANCY SENSORS
PERMITTED TO BE WIRED TO POWER PACK
NUMBER OF ADD-A-RELAYS PERMITTED
PERMITTED TO BE WIRED TO POWER PACK
1
0
2
0
3
0
1
1
2
1
2.35
(59.7 mm)
3.66 (93.0 mm)
1.38
(35.1 mm)
Commercial Grade Power Packs for Occupancy Sensors
• For use with: ODC20-M, ODC10M, ODC05-M, ODC20-U,
ODC10-U, ODC05-U, ODC04-I,
ODW12-M, ODWWV-I and
ODWHB-I.
• Self-contained power supply for
occupancy sensors & switching
relay for lighting loads.
• Provides 24V DC 100 mA nominal, full-wave rectified and filtered
power for occupancy sensors
and Add-A-Relay units.
• Available in 120VAC, 230VAC,
277VAC and 347VAC versions
with relay contacts rated for 13
amps incandescent or 20 amps
lighting ballast loads.
• Compact size and light weight
allows easy mounting through
knockout in junction box (from
either inside or inside the box)
with a simple twist-on nut.
STANDARDS & CERTIFICATIONS
N
ODP20, ODP15, ODA13
To learn more about Leviton devices or for answers to technical questions call our Techline at
1-800-824-3005 or visit us at:
www.leviton.com
10
Outdoor Motion Sensors
Commercial Grade
SPECIFICATIONS & FEATURES
PROFESSIONAL SERIES
OUTDOOR PIR MOTION SENSORS
STANDARDS & CERTIFICATIONS
UL
Listed
CSA
Certified
• Ideal for a wide range of commercial/industrial settings including parking areas, storage facilities,
warehouses, loading docks, marina, garages, walkways, campus grounds, meat lockers, walk-in
refrigerators/freezers and outbuildings.
• Adjustable Delayed-OFF time settings from 20 seconds (for test mode) to 15 minutes.
• Adjustable sensitivity and immunity to RFI signals reduces false triggers.
• Ambient light override prevents lights from turning ON when there is ample natural light.
Commercial Grade Outdoor Motion Sensors
• Provides Automatic, Test and Continuous Modes—Test mode simulates automatic operation with
short delayed-OFF time for ease of making adjustments. Continuos mode enables manual override
for constant “lights ON” operation (when used with standard ON/OFF switch).
• Surge suppression minimizes likelihood of damage due to electrical surges.
• Temperature compensation feature ensures uniform performance in extreme hot or cold weather and
during temperature fluctuations.
• Sensor neck adjustment allows accurate area monitoring: 110° vertical, 180° horizontal, 110° rotational.
PS200-1FW
Outdoor Motion Sensors
Passive Infrared (PIR) outdoor motion sensor provide outstanding value in security lighting, convenience, safety and energy savings for a wide
range of commercial and residential applications.
COLOR
CATALOG NUMBER
DESCRIPTION
COVERAGE
Commercial Grade Outdoor Motion Sensors
White
PS200-10W
Professional Series Outdoor
PIR Motion Sensor
RATING
200°
Incandescent: 1000W @ 120V
Fluorescent/Inductive:
500VA @ 120V. For 60Hz AC only
Brown
PS200-10B
Professional Series Outdoor
PIR Motion Sensor
200°
Incandescent: 1000W @ 120V
Fluorescent/Inductive:
500VA @ 120V. For 60Hz AC only
White
PS200-1FW
Professional Series Outdoor
PIR Motion Sensor with
Dual Floodlights
200°
Incandescent: 1000W @ 120V
Fluorescent/Inductive:
500VA @ 120V. For 60Hz AC only
Brown
PS200-1FB
Professional Series Outdoor
PIR Motion Sensor with
Dual Floodlights
200°
Incandescent: 1000W @ 120V
Fluorescent/Inductive:
500VA @ 120V. For 60Hz AC only
White
PS110-10W
Professional Series Outdoor
PIR Motion Sensor
110°
Incandescent: 1000W @ 120V
Fluorescent/Inductive:
500VA @ 120V. For 60Hz AC only
Brown
PS110-10B
Professional Series Outdoor
PIR Motion Sensor
110°
Incandescent: 1000W @ 120V
Fluorescent/Inductive:
500VA @ 120V. For 60Hz AC only
White
PS110-1FW
Professional Series Outdoor
PIR Motion Sensor with
Dual Floodlights
110°
Incandescent: 1000W @ 120V
Fluorescent/Inductive:
500VA @ 120V. For 60Hz AC only
Brown
PS110-1FB
Professional Series Outdoor
PIR Motion Sensor with
Dual Floodlights
110°
Incandescent: 1000W @ 120V
Fluorescent/Inductive:
500VA @ 120V. For 60Hz AC only
N
11
5.36 (136.1 mm)
9.16 (232.7 mm)
4.50 (114.3 mm)
2.48
(63.0 mm)
PS200
To learn more about Leviton devices or for answers to technical questions call our Techline at
1-800-824-3005 or visit us at:
www.leviton.com
Download