Integrated Environmental Solutions Virtual Environment 2015 Release Notes June 2015 Contents VE 2015 Changes ..................................................................................................................................... 0 VE 2015 Changes ApacheHVAC Crash prevented in System Schedules and Setpoints dialog [ID-0078756]: A crash has been prevented in the System Schedules and Setpoints dialog when trying to assign a set of profiles to an already loaded HVAC network. Range limit for "Fraction of design motor power (%)" increased [ID-0077449]: Fan fraction of design motor power accepts percentage values in excess of 100% of the design value. The range limit is now set to 0-150%. Controlled variable column now displayed in Tabular Edit [ID-0071918]: Tabular Edit now displays the controlled variable column when in multiple edit mode. Crash prevented in "Edit System Parameters" dialog [ID-0077881]: A crash has been prevented when closing the "Edit System Parameters" dialog. HVAC sensor collision box correction [ID-0076350]: The placement of the collision box has been corrected when a controller is placed above a vertically-orientated duct. Design COP corrected [ID- 0076754]: The design coefficient of performance for the the performance curve sets “screw/1compressor” and "hermetic reciprocating; 1 Compressor" have been corrected. Cooling tower fan power can no longer exceed design fan power [ID-0076875]: The maximum airflow fraction the fan can run at is the design (full) air flow. Hence, the tower operating fan power should be constrained by the design fan power. This constraint has been added in the cooling tower model, so that you will not see cooling tower fan power exceeding the design fan power. Autosizing error prevented in Chilled Ceiling controllers [ID-0077644]: Changes made to the Loads data spreadsheet to prevent negative autosizing values mainly in the event of Chilled Ceilings / Radiant Cooling Panels where room loads are low and ventilation rates are high. ApacheSim NCM lighting control is applied only when the input mode is lux or inference [ID-0070661]: When you commit changes to an internal gain its 'Use NCM simple lighting control' option is only set if its input mode is either lux or inference. Limiting capacity conversion correction [ID-0026290]: The Simulation Heating and Cooling Unit Capacity values are now converted correctly when switching units between metric and IP. Results from Solar Hot Water Buffer simulation corrected [ID-0076237]: Issue corrected relating to the Solar Water Heater when connected to the Hot Water Loop of an ApacheHVAC network. The tank temperature is no longer updating faster than simulation timestep. ApLocate ASHRAE design weather data correction [ID-0057520]: Richmond Intl Airport was listed in the wrong state. It has been updated to Virgina. ApPro Copy and Paste no longer removes values and decimal places [ID-0075192]: Copy and Pasting into the same profile will no longer remove rows or reduce the number of decimal places. Apache View DHW storage insulation thickness precision reduced [ID-0071062]: You can now only input the DHW storage insulation thickness in mm to one decimal place. Building Template Manager Add system button creates a new default system [ID-0039130]: The Add button will add a new system called "New System" with default values. The duplicate button will copy the currently highlighted system. "Show NCM?" option added to BTM [ID-0072660]: An option to show or hide NCM templates has been added to Building Template Manager. It is set to hide by default. Component Modeller Object Selection in component modeller is now consistent [ID-0069761]: Selecting part of a component in the workspace will also select the correct part in the browser. Constructions Material description can be edited [ID-0066934]: You can now edit the Material description through the Opaque and Glazed construction dialogs. When you double-click on the description field it will strip the "[ID]" prefix and let you modify the description, after you have finished editing it will then re-add the "[ID]". Constructions properly removed when manually deleted [ID-0043713]: Under certain circumstances removing or deleting a construction would not get saved. Now they will be properly deleted. CDB UI improvements [ID-0071860]: A few improvements have been made in the CDB dialog: The redundant "New" dropdown in the Ceiling and Int Partition dialog has been removed. Ext shading device transmission factors are no longer partially hidden. The Material column name is once again editable. FlucsDL/FlucsPro Special characters no longer cause issues [ID-0075875]: Special characters in room names no longer cause problems in the XML files used in report transformations. Daylight calculation correction [ID-0075582]: Some daylighting VERS calculations use multiple time simulations, storing results for each time simulation, and combining them to get overall results for the report. Results based on these simulations are no longer over-counted by the number of working planes. VE-Gaia VE-Gaia Solar report contains images [ID-0077555]: The reports generated by the VE-Gaia Solar Navigator are generated correctly and will include images from Model Viewer 2. General Save dialog loop prevented [ID-0077278]: Save dialog loop prevented when running a New Zealand or Singapore compliance simulation on an unsaved project. Single file limit when using Export to CSV feature [ID-0063438]: Only one results file can be selected when using the Export to CSV feature. Trailing spaces in project name and directories are removed [ID-0077338]: When saving a project, trailing spaces in the name and directories are removed. Create new project based on template updated [ID-0076566]: New template "Office UK" has been added to replace the one old one. Tab Room Data shows correct tabs [ID-0078237]: When switching back to ModelIT after running a compliance simulation, Tabular Room Data will show the real building. The NCM tabs will not be shown. South Africa EPW Weather Files added [ID-0076041]: South Africa EPW Weather Files to have been added to the shared content. Crash prevented when cancelling archive [ID-0073274]: In some circumstances when cancelling the archive procedure when the project includes results files could cause a crash. This has now been prevented. MacroFlo Errors prevented when project name contains dots [ID-0069746]: When the project name contains dots then there are no longer issues when entering MacroFlo. Equivalent orifice area updated when making changes in Tab Edit [ID-0078785]: The Equivalent Orifice Area is now updated correctly when modifying relevant values in Tabular MacroFlo. MicroFlo CO2 and CO scale display corrected [ID-0060540]: CO2 and CO scale is now displayed to 2 decimal places. Seed Point Coordinates displayed correctly [ID-0076421]: The Seed Point Coordinates are now shown correctly in the Slice Display Settings dialog. ModelIT Surfaces colour corrections [ID-0075591] In some models the internal holes were inadvertently being coloured yellow in the workspace rather than turquoise/blue (as default). This has been corrected. Folder path case retained when archiving project [ID-0078228]: When using the Archive Current Project option, the folder path won't be forced to lowercase. The case of the path selected will be retained. Model report DHW Consumption shows correct units [ID-0076720]: In the Thermal Templates section of the Model Report, the DHW Consumption has the correct units displayed. Correct profiles displayed in Model Report [ID-0076731]: In the Model Report it now displays the correct profiles as used in the templates. Orientation of PV panel components consistent between Model Viewers [ID0075736]: When viewing a model in both Model Viewer and Model Viewer II, the orientation of the PV panel components will be the same. Coordinates in Edit Vertices window refresh on undo/redo [ID-0073945]: When editing vertices and then using undo/redo, the coordinates will now be updated correctly. "Slice" showing colours for either "Layers" or "Room Groups" [ID-0076977]: The Slice dialog has options to show colours, it can now show the colour "By Layer", "By Room Group" as well as "By Object". Sub-spaces highlighted when selected [ID-0073986]: In the Separate Spaces dialog, sub-spaces will be correctly highlighted when selected. Rename dialog improvements [ID-0076826]: When using the Rename dialog in ModelIT (type rename into the key-in field), the OK button is highlighted by default so pressing Enter key will apply the changes. Model Report Thermal data corrections [ID-0074030]: The Thermal template values in the Model Report now match the selected templates data. Stamp Tool image displayed at cursor [ID-075168]: When using the Stamp Tool the image of the stamp is placed at the cursor. Stamp Tool cancelled when right click or press Esc [ID-0075167]: After using the stamp tool right clicking or pressing Escape key will deactivate the tool. Model Report create room group schemes improvements [ID-0076002]: When creating room grouping schemes for consistency checks in the Model report dialog, all groups will be created if the option is checked. If the "Remove scheme if no problems" is also checked then only the schemes that have problems will be created. Browser tree no longer collapses when zones deleted [ID-0074594]: Deleting zones in ModelIT will no longer cause the model browser tree to collapse. "Separate Spaces" toolbar button is disabled unless a composite space is selected [ID-0073982]: The "Separate Spaces" toolbar button will be disabled unless a composite space is selected. Average height removed from Model Report [ID-0075033]: The average height has been removed from the Model Report and has been replaced by base height and body height. Connect Spaces dialog improvements [ID-0069821]: Deselecting rooms with Ctrl click refreshes the Connect Spaces dialog. Monodraught Cool-Phase room group placement correction [ID-0061532]: In the Shape Setting dialog, when drawing a zone and selecting the Monodraught Cool-Phase group, the zone will be placed in the correct group. Group selection now displayed in Connect Spaces dialog [ID-0078031]: Selecting/Deselecting Groups from the room browser displays the rooms in Connect Spaces dialog list. Changing room type from Tabular Room Data rebuilds adjacencies [ID-0078250]: In ModelIT when two rooms are adjacent, changing the room type through Tabular Room Data will now rebuild the adjacencies automatically. Editing operations on a zone no longer cause Luminaires to be lost [ID0078176]: Editing operations e.g. cutting, merging, subtracting, partitioning etc no longer cause any defined Luminaires to be lost. Model Report external hole correction [ID-0078464]: If a surface is split to have an internal and an external portion and the internal portion includes a hole, then the Model Report no longer flags this room as containing an external hole. Partition tool improvements [ID-0076841]: Improvements have been made to the partitioning tool to prevent invalid spaces from being created. Correction made when deleting storeys [ID-0073227]: When deleting all zones in a storey, the selected storey will update and the view will be correctly displayed. DXF room names now shown [ID-0075129]: When you attach a DXF file the room names now appear in the ModelIT viewport. Key-ins at opening display level corrected [ID-0074741]: When the display mode is set to "Opening and when using the "Open=" key-in, only the openings currently highlighted will be updated. Model Viewer II Smooth edges in MVII [ID-0075216]: When you view models in Model Viewer II the bounded box edges are no longer jagged and pixelated, they will be smooth. Pan functionality improvements [ID-0073246]: When using the number pad to switch views, the pan functionality works as expected. Images can be saved when extended ASCII characters are used [ID-0077175]: In Model Viewer II images can be saved when the path contains extended ascii characters. Solar Arc no longer passes through building [ID-0076427]: On taller models the solar arc will no longer appear to pass through the building. Assigning certain textures correction [ID-0076503]: Assigning the Flat (FLATxxx), Water (WATxxx) or Miscellaneous (WINDxxx) textures to surfaces no longer breaks the colouring in MV2. VE Navigator for BREEAM Only selected spaces reflected in BREEAM HEA10 report [ID-0076728]: The BREEAM Comfort Report includes only the selected rooms in the analysis based on the user selection in Select spaces dialog. ASHRAE 90.1 App. G - PRM Duplicate confirmation dialog removed from Profile Weekly Pattern Editor [ID0038124]: In the Update profile working week order section, only one confirmation dialog will be shown. Profiles will only be updated once. Daylight sim can be run on building with a modified orientation [ID-0077243]: If the Building orientation has been modified then when you run through PRM workflow the Daylight simulation will complete with no errors due to the site rotation. Erroneous error message removed [ID-0058973]: Erroneous error message removed when deleting all the characters from the "Floor Area" control in the Baseline HVAC System Selection dialog. Edits made in the infiltration dialog are now saved [ID-0057572]: Changes made to Air Exchanges in the Infiltration item of the PRM navigator will now be saved when you click OK. System parameters Pressure drop text label updated [ID-0075340]: It now says "System Pressure Drop Adjustment" with the units "iwc" (inches water column). Radiance Crash prevented when generating image [ID-0072250]: Crash prevented in certain models when generating a Luminance image with components switched on. Graphic showing Eye/Focus corrected [ID-0074968]: When in Plan view the correct position and associated graphic is shown based on eye/focus settings. Results file list improvements [ID-0075777]: When you have more than one WPD files for the same zone, selecting anything other than the first in the list would previously jump back to the first one. This has been corrected. Map file updated when components deleted [ID-0074452]: Deleting components will delete the map file reference to the component, which means the map file colours assigned to new components will be correct. Crash prevented running simulation with inner volumes switched on [ID0074439]: A crash has been prevented on certain models when running a Radiance simulation with inner volumes switched on. Default eye position updated for "Hemispherical Fisheye" or "Angular Fisheye" views [ID-0070709]: The default view is now the centre of model (or centre of zone) with view set to the south west. Daylight factor units displayed in projects containing a dot [ID-0077416]: Can now display the daylight factor units in projects that have a filename containing a dot. Crash prevented when entering Radiance [ID-0076860]: A crash has been prevented when switching to Radiance when the default sky file is set to 10K CIE Overcast sky. Tariff Analysis Oil value in report matches the tariff dialog value [ID-0074478]: The oil value in the report now matches the oil value shown in the Tariff dialog. VE Compliance CO2 emissions on Compliance Report bar chart displayed to 2 d.p [ID-0075035]: The number of decimal places in the horizontal bar charts has been set to 2 d.p so Vista Compliance Report matches the tables in the UK Part L Energy Performance & CO2 Emissions report. Glazing and rooflight percentages are now displayed separately [ID-0075078]: In the UK Part L2A DSM Navigator comparison report, the glazing and rooflight percentages are now displayed separately. Duplicate "Constant 0" profile no longer created [ID-0075566]: When first entering VE Compliance, a duplicate "Constant 0" weekly profile (and its associated daily profile) is no longer created. Design Comparison report corrections [ID-0075079]: The Comparison Report displays the rooflight percentage per surface orientation in the box diagram. It is now the same as in the Project Summary section. "High Pressure Air Drop?" no longer editable in Notional Building [ID-0043761]: The "High Pressure Air Drop?" checkbox on the Building Regs tab of Room Query is no longer editable when you are in the Notional Building. Tabular Apache Systems correct heating fuels are selected [ID-0075194]: When selecting heating fuels in Tabular Apache Systems, the correct heating fuel will be displayed and selected. Tabular Apache Systems enabled values match Apache Systems [ID-0075198]: Values that cannot be edited when in Apache Systems now cannot be edited when in Tabular Apache Systems and vice versa. Tabular Apache Systems range validation updates [ID-0075195]: The range checking validation limits are now consistent between Tabular Apache Systems and normal Apache Systems. Tabular Room Data imported only allows valid Occupancy Switching import [ID0074941]: If a room doesn't support the manual switching options for Occupancy Switching, and you attempt to set them via a Tab Room Data import from Excel, an error message will be displayed for the room(s) in question at the end of the import process and the values for the rooms in question will remain unchanged. Portable or Modular Building Factors updated [ID-0077319]: The Target Emission Rate factors for Portable or Modular buildings were updated for Part L 2013 - England. DCV Type and Air flow regulation selections retained [ID-0076283]: The Demand Control Ventilation Type and Air flow regulation selections are not affected by switching between applications. SBEM NCM Lighting Data interface change for 2013 regs [ID-0072584]: Design illuminance is now available as an input for 'chosen but not calculated' and 'only lamp type known' SBEM design options for PartL2 (2013)- England and PartL2 (2014) - Wales. District Heating Seasonal Efficiency correction [ID-0072416]: When the Heat Source is set to be District Heating the system heat source seasonal efficiency is set to 1 (i.e. 100% efficient heat source and all system performance aspect set via District Heating CO2 Conversion factor). BRUKL Heat Fuel Type correction [ID-0036506]: When using a District Heating system the BRUKL certificate generated from ApacheSim no longer shows HFT (Heating Fuel Type) = Grid Supplied Electricity in the HVAC Systems Performance section of the BRUKL certificate. Adjacent building adjacency condition correction [ID-0071490]: For an adjacent building the adjacency condition at surfaces where it meets a conditioned room is no longer being affected by whether the adjacent building has a system assigned or not. Crash prevented when generating BRUKL with link to ApacheHVAC but no proxy apache system [ID-0062781]: A crash has been prevented when trying to generate a BRUKL when the simulation uses ApacheHVAC but the Proxy apache system isn't assigned to any rooms. A warning will now be shown advising to define and assign the proxy system. Crash prevented when Lamp type set to "Fluorescent (no details)" [ID0074510]: A crash has been prevented when generating an SBEM EPC when the Lamp type is set to "Fluorescent (no details)". Building area type default checkbox retained on VE 6.1.1 model upgrade [ID0075682]: When upgrading a VE 6.1.1 model, if the model and a thermal template have different NCM building types, then the room with the thermal template set will now retain its ticked default checkbox for its building area type. HVACGUIDE-SFP written out correctly [ID-0074255]: When you have a natural ventilation system (i.e. heating only and Vent mechanism is chosen as natural ventilation) then the HVACGUIDE-SFP value should be written to BRUKL as code -1111 so it appears correctly on the BRUKL. Zone level ventilation can now be set in VE-SBEM [ID-0076993]: When the Apache System ventilation has been set to "Natural Ventilation", then the "Is there mechanical supply in this room?" checkbox will be visible in SBEM mode. You can then set a zone level fan power. Section 6 Notional system uses correct heating tab efficiencies [ID-0076206]: The Section 6 Notional system uses the correct heating tab efficiencies when switching from electricity to district heating in the actual building. Input Data Visualisation displays correct templates values [ID-0075974]: When using the Input Data Visualisation tool while in Compliance the correct values from the template are displayed. Notional building model error message removed [ID-0062859]: When upgrading a model and running ApacheSim compliance using the existing results you will no longer get the message "Notional building model not present" when it switches to run the notional sim. User entered air permeability values retained [ID-0076063]: If a project is upgraded from Part L2 2010 to any other non-residential compliance regulations, the air permeability picks up the value entered in Part L2 2010 only in case where the default option is ticked. Crash prevented when generating BRUKL for shell and core building with no core areas [ID-0061625]: A crash has been prevented when BRUKL.exe is running when you have an 'As designed' Shell and core building but with no 'Core' areas. Air exchange assignment corrections [ID-0056995]: If you have a thermal template that has additional air exchanges of type Infiltration, Auxiliary Ventilation and Natural ventilation and assign this template, only the Natural ventilation air exchange should be assigned to the room and the Infiltration and Aux Vent should be ignored when in VE Compliance. Local manual switching corrections [ID-0013868]: Local manual switching in spaces in the actual building is no longer limited to zones under 30m2. This limit will still apply to the notional and reference buildings. See paragraphs 70, 84 and 161 of the NCM modelling guide for more information and further conditions. DCV is applied to the notional building in DSM simulations [ID-0077075]: As per the NCM modelling guide, in zones with mechanical ventilation the Notional building will benefit from demand control of ventilation through variable fan speed control based on CO2 sensors. Vista Radiators dialog error removed [ID-0026893]: On the Radiator selection dialog clicking the "Apply default radiator to all rooms" button no longer results in an error. WAHP water loop temperatures variables reinstated [ID-0058990]: The following WAHP Vista variables have been reinstated; Water entering temperature, water leaving temperature and Water delta T. Switching between graphs improvements [ID-0070075]: Switching between Peak Day Graph and Graph no longer restricts the range of dates available to select. Browser improvements when viewing HVAC network [ID-0078032]: Switching between results files with the HVAC network displayed causes the browser to refresh correctly and the correct components are displayed. Selected time is maintained in MVII when switching between result files [ID0070072]: When using the visual analysis option in Model Viewer II, the selected time is retained when switching between results files. Custom variables that use both weather and component data now perform interpolation [ID-0074464]: If a custom variable is created that uses a weather data variable and a component output variable, interpolation is now performed when the reporting interval is less than one hour. Scale unit conversion applied [ID-0076474]: In VistaPro Visual Analysis (Model Viewer II) unit conversion is applied to the scale. Crash prevented using range test tool [ID-0076341]: A crash has been prevented when using the Range test tool and deleting the contents of the "above" or "in steps of box" text boxes. Custom variables listed when switching to VistaPro [ID-0074480]: The custom variables are displayed before refreshing the list. Crash prevented when recreating custom variable [ID-0074233]: A crash has been prevented when you recreate a custom variable that was previously deleted. Renaming Custom Variable updated [ID-0074690]: The new name of a custom variable shows up in the variable browser after renaming and clicking OK in "Manage Custom Variables" dialog. Custom HVAC Component variables listed correctly [ID-0074479]: When you create a custom HVAC fan component variable that references a weather file, it will be listed under the Fan component level as expected. Combine Openings works as expected at opening level [ID-0074825]: When Combine openings is ticked, VistaPro plots results for all the selected openings. HVAC filename display corrected [ID-0075254]: When selecting the HVAC file grouping scheme to access HVAC results, the filename shown will be the file associated with the selected results file. SET variable reinstated [ID-0078193]: The Standard effective temperature variable has been reinstated. Advanced cooling coil calculation of leaving moisture content correction [ID0067125]: At near zero levels of wet fraction, the advanced cooling coil calculates leaving moisture content greater than entering moisture content. This discrepancy is in the order of 0.1% (of total moisture content). The leaving moisture content will be set to equal the entering moisture content when evaluating for wet coil conditions in the situation where this discrepancy occurs. SunCast SunCast Analysis displays correct results on surfaces [ID-0077110]: The solar exposure after running the analysis will display the correct results. Previously some surfaces would appear to be missing results for high resolution grids. Crash prevented when running SunCast calculation [ID-0076476]: A crash has been prevented under certain circumstances where the INI file in SunCast has become out-of-sync with the model. Shadow display improvements [ID-0074688]: In some scenarios Topographical & Local shades were causing problems with the display of shadows on an image. This has been corrected. Apply button active when changing the custom gradient scale [ID-0074160]: In the SunCast Analysis tab, the apply button is now active after changing the custom gradient scale. Accessing Preferences menu no longer resets room browser [ID-0061541]: If you open and OK the preferences dialog when in SunCast, the rooms browser will no longer reset. Changing room grouping scheme no longer switches tabs [ID-0076941]: When selecting a new group from the Room Group dropdown the view will no longer be switched to either of the additional tabs. SunCast image generation improvements when importing SketchUp models [ID0077091]: When importing a model from SketchUp where the shading surfaces have windows, then the openings are now considered as 100% opaque when generating SunCast images. This is consistent with the convention that you cannot have openings in shading objects designed in the VE. GSK error messages more informative [ID-0076335]: If you encounter an error due to complex shading objects then the error log will be more informative. It will be in the following format – "GSK@<Line Number>: [<Room ID>] <Error message>" e.g. GSK(1234): Main Office, Surface 14 - Invalid number of openings (2). Parallel SunCast calculation will only run for selected months [ID-0076688]: When using parallel SunCast with multiple cores, calculations will only be performed for the selected months rather than for the whole year. Solar Analysis custom scale displays correct values [ID-0074159]: When in IP units, the correct values will be displayed in the Solar Analysis custom gradient scale. GMPro Constructions added to correct category [ID-0074786]: The element types for the constructions GMB_0032 and GMB_0048 have been added to the correct category. Sizing error prevented [ID-0077927]: A sizing error had been prevented when doing a GMPro HVAC sizing run with system 10. Parametric Batch Processor Edits to range input retained [ID-0076628]: In the Parametric Batch Processor dialog, any edits made to the ranges will be retained. Master Templates Master Templates & Design Options Restore point time corrected [ID-0063036]: The correct time will be used when a restore point is created. Crash prevented when using Master Templates [ID-0061754]: A crash has been prevented when using Master Templates on a project with missing templates. You will now get a warning about invalid changes and will be asked if you want to view the log file. Matched room name improvement [ID-0076739]: Previously when importing a model through Master Templates, if a target room has part of the source room name it would be matched up even though there is a target room with the exact name available. This has been corrected. Design Options Design Options improved so that constructions with existing IDs are replaced [ID-0075889]: Design Options is improved so that replacing constructions with a new construction that has the same ID imports a unique ID and this is assigned to the model as specified in the rule. Title 24 ParallelFanBox fan capacity is set based on Induction Ratio [ID-0074761]: Air system Terminal units of type Parallel Fan Box will have fan flow capacity calculated as product of Maximum Primary Flow and Induction Ratio. Internal holes written out correctly [ID-0074554]: When model contains holes between rooms they are written out to CBECC with properties to avoid an error in the simulation.