Powering a Cleaner Tomorrow. eMission Diesel Generator Aftertreatment (AT) Systems Family Clean, Reliable Power. Every Time. ēMission Tier 4 products reduce the NOx, CO, HC, and Particulate Matter (PM) levels in the exhaust stream from Tier 2 to Tier 4 interim or Tier 4 Final levels as specified by the United States Environmental Protection Agency (EPA), providing compliance with optimum performance, reliability, and versatility for all applications. The ēMission Diesel Particulate Filter-only (DPF-only) product is designed specifically for sensitive receptor areas and provides better than 95% Particulate Matter reduction. The ēMission product is fully integrated and tailored to Cummins Power Generation generator sets, with performance demonstrated through long term EPA Deterioration Factory testing meeting the Two 1500 kW 50L Cummins Power Generators with Tier 4 Final aftertreatment systems in Fullerton, CA highest standards in the industry. Control Panel Display: Displays critical parameters on screen through a user friendly interface System Features and Benefits Exhaust Blanket: Standard installation for minimized heat rejection to enclosed environments Integrated Load Bank (ILB): Automatically regenerates DPF to maintain optimum performance and ensures faster system compliance, without need for floor mounted load bank Self-Cleaning Airless Injection System: Patented Diesel Exhaust Fluid (DEF) injector does not require a compressed air source Closed Loop Control System: Product communicates with generator, ensuring consistent emissions control as operating conditions change Durable Stainless Steel Construction Diesel Exhaust Fluid Tank: 225 gallon tank with integrated level sensor IBC Seismic Certified Tier 4 Final Requirements All certified systems with engines manufactured after January 1, 2015 must be Tier 4 Final for stationary non-emergency use Major Sources/Title 5 facilities may require Tier 4 Final A Diesel Particulate Filter (DPF) is required on engines located within 100 meters of schools in California Tier 4 Final is required for California demand response programs Tier 4 Final is required by SCAQMD for any non-emergency applications and near sensitive receptors Selecting the Correct AT System Certified: Unlimited operational hours, prime power applications, no EPA restrictions, local restrictions may apply Five 2250 kW 60L Cummins Power Generators with Tier 4 interim certified aftertreatment systems in Coit, TX Compliant: Unlimited emergency operation during outages, 100 hours/year maximum for non-emergency, 50 hours/year for demand response/peak shaving (SCAQMD Rule 1110.2), additional restrictions may apply Aftertreatment Systems Product Line Tier 4 Final For NOx Non-attainment Areas, Major Sources/Title 5 NOx HC CO PM 0.67 0.19 3.50 0.03 Units in g/kW-hr Tier 4 Interim For Non-attainment Areas PM NOx HC CO PM 0.67 0.40 3.50 0.10 (ILB Optional) DPF-Only Units in g/kW-hr For Sensitive Receptor Areas NOx HC CO PM 6.40 0.19 3.50 0.03 Units in g/kW-hr Key Terminology Southern California Air Quality Management District (SCAQMD) Rule 1110.2: Legislation designed to improve compliance of stationary engines and achieve emissions reductions based on the cleanest available technologies. Affects Los Angeles, Orange, Riverside, and San Bernardino Counties Title V: Federal program designed to standardize air quality permits and the permitting process for major sources of emissions across the country. Major sources are facilities that emits, or has the Potential to Emit (PTE) any criteria pollutant or Hazardous Air Pollutant (HAP) at levels equal to or greater than the major source thresholds Non-Attainment Areas: Areas that do not meet EPA National Ambient Air Quality Standards (NAAQS) 40 CFR Part 50 for ozone and particulate. These areas include California, Houston, Atlanta, Chicago, Boston Demand Response: Programs designed to enable customers to contribute to energy load reduction during times of peak demand. California’s demand response program is limited to 75 hours/year and require local district approval Sensitive Receptors: Any residences with living quarters including private dwellings, health facilities, hospitals, prisons, and dormitories. SCAQMD requires Tier 4 interim PM levels on engines located within 50m AT System Size Specifications Height Length Genset Rating 2500-2750kw 1250-2250kw 750-1000kw Engine 78L 50L/60L 30L Width Typical Enclosure Dimensions Aftertreatment (AT) System Dimensions Enclosure Option Length Width Height Weather Protective Level I 380 in 420 in 134 in 134 in 200 in 200 in Level II, III 440 in 134 in 200 in Enclosure Option Length Width Height Weather Protective Level I 320 in 360 in 120 in 120 in 182 in 182 in Level II, III 375 in 120 in 182 in Enclosure Option Length Width Height Weather Protective 260 in 303 in 98 in 98 in 142 in 142 in 315 in 98 in 142 in Level I Level II, III AT System Length Width Height 2 Ducts 54 in 183 in 142 in 60 in AT System Length Width Height 2 Ducts 45 in 183 in 124 in 51 in AT System Length Width Height 1 Duct 45 in 183 in 58 in 51 in Cummins Power Generation, a subsidiary of Cummins Inc. (NYSE: CMI), is a global leader dedicated to increasing the availability and reliability of electric power around the world. With more than 90 years of experience, its global distributor network of distributors in over 190 countries delivers innovative solutions for any power need - commercial, industrial, recreational, emergency, and residential. Cummins Pacific, LLC is the exclusive California and Hawaii distributor for Cummins, Inc. Cummins Pacific provides service, support, and sales of all Cummins products through 12 Service Centers. 1939 Deere Ave. Irvine, CA 92606 (800) 746-5757 cumminspacific.com Arcata (707) 822-7390 Bay Area (510) 351-6101 Ventura (800) 881-1159 Inland Empire (800) 653-4373 Redding (530) 244-6898 Fresno (559) 274-4400 Los Angeles (866) 934-4373 San Diego (800) 993-4373 Sacramento (916) 371-0630 Bakersfield (661) 325-9404 Santa Fe Springs (800) 746-5757 Hawaii (808) 682-8110