Section 6. Tray Cables

advertisement
Section 6.
Tray Cables
Tray Cables
800.633.6339 • www.lapptannehill.com
149
Table of Contents
Lapp Group
ÖLFLEX® TRAY II & TRAY II CY .................................................................................151
ÖLFEX® FORTIS .........................................................................................................152
ÖLFEX® CONTROL TM/ TM CY .................................................................................153
Instrumentation Cables 300V
Type PLTC Single Pair or Triad Non-Shielded .............................................................154
Type PLTC Single Pair or Triad Shielded .....................................................................154
Type PLTC Multiple Pairs, Overall Shield .....................................................................155
Type PLTC Multiple Pairs, Individual and Overall Shield . .................................... 156-157
Type PLTC Multiple Triads, Individual and Overall Shield ............................................158
Tray Cable-Control Cable 600V
Type TC-ER Multiple Pairs, Overall Shield....................................................................159
Type TC-ER Multiple Pairs, Individual and Overall Shield..................................... 160-161
Type TC-ER Multiple Triads, Individual and Overall Shield ..........................................162
Type TC-ER TFN Insulation PVC Jacket, Copper Conductors......................................163
Type TC-ER THHN or THWN Insulation PVC Jacket ...................................................164
Type TC-ER THHN or THWN Insulation PVC Jacket ...................................................165
Type TC-ER THHN or THWN Insulation PVC Jacket ...................................................166
Type TC-ER TFN Insulation PVC Jacket . ....................................................................167
Color Code Chart . ........................................................................................................168
Specifications subject to change. For complete specifications and availability visit www.lapptannehill.com
150
Tray Cables
800.633.6339 • www.lapptannehill.com
Tray Cables
ÖLFLEX® TRAY II/II CY, Flexible & Oil Resistant Tray Cable with both
UL & CSA TC Approval for Industrial Applications
ÖLFEX® TRAY II -(UL) TYPE TC-ER OR DP-I 90ºC 600V---c(UL) TC/CIC FT4--CSA AWM FT4 RoHS
Construction: Finely stranded bare copper conductors; Insulation: Specially blended PVC/nylon insulation;
Jacket: Specially formulated oil resistant black PVC jacket.
ÖLFEX® TRAY II CY-(UL) TYPE TC-ER OR DP-I 90ºC 600V---c(UL) TC/CIC FT4--CSA AWM FT4 RoHS MSHA
Construction: Finely stranded bare copper conductors; Insulation: Specially blended PVC/nylon insulation. 100% shielding with foil tape and tinned
copper braid (70% coverage); Jacket: Specially formulated oil resistant black PVC jacket.
Features:
ÖLFLEX® TRAY II/II CY is an industrial grade tray cable with superior oil performance for long cable life. It has a pressure extruded jacket and fine
copper stranding for excellent flexibility making it much easier to pull through tray. With UL TC-ER approval, no conduit is needed so you can reduce
material costs along with saving on labor.
Applications:
Industrial plant expansions, Automotive plants, Tray wiring, anywhere that VNTC® cables are used.
ÖLFLEX® TRAY II: Flexible and Oil Resistant Tray Cable
Technical Data:
Minimum Bending Radius for installation:
< 1 AWG: 5 x cable diameter.
> 1 AWG: 7.5 x cable diameter.
Please note that VNTC® is a trademark for
General Cable Technologies Corporation.
Temperature: •<
-40ºC to +90ºC
UL/CSA TC.
• -40ºC to +105ºC
UL AWM
Rated Voltage:
• 600V - TC
• 1000V - AWM
• 1000V - TC
Wind Turbine (WTTC)
Color Code:
• Black with white numbers
plus green/yellow ground
ÖLFLEX® TRAY II CY: Shielded Flexible and Oil Resistant Tray Cable
Tray Cables
800.633.6339 • www.lapptannehill.com
Approvals:
UL:
• Type TC-ER (Exposed Run)
or DR-1
• UL AWM, Oil Res I,
Wet Rating 75ºC UL 83
• UL MTW, NFPA 79 2007
• Class 1, Div. 2 per NEC Art.
336, 392, 501
• Submersible pump
(14 AWG & Larger:
2 to 7 conductors)
CSA: • c(UL) Type TC and CIC FT4
• CSA-AWM I/II A/B FT4
Additional: • MSHA-P-07-KA050016-MSHA
(Shielded Only).
• Torsion tested for wind market
(+/- 150º/m)
151
Tray Cables
ÖLFLEX® FORTIS, Flexible & Oil Resistant Tray Cable with UL/CSA
and Excellent Cold Temperature Flexibility
LAPP KABEL STUTTGART ÖLFLEX® FORTIS P/N 331404- 14 AWG (2.50MM2)/4C (UL)TYPE TC-ER THHN/THWN 90ºC DRY 75ºC WET
600V, SUN RES, OIL RES I/II E171371 or MTW “FLEXING” or WTTC 1000V 90ºC DRY, or c(UL) CONTROL CIC/TC PVC/N -40ºC OUTDOOR
FT4 -- CSA AWM II A/B 90ºC 600V FT4 CE ROHS
Construction: Finely stranded bare copper conductors; Insulation: Specially blended PVC/nylon;
Jacket: Formulated oil resistant and elastomeric polymer alloy black jacket.
Features:
ÖLFLEX® FORTIS is named after the Latin Word meaning “strength”. It offers outstanding mechanical performance, particularly at low
temperatures. The specially formulated elastomeric jacket passes UL’s -40ºC cold impact test. ÖLFLEX® FORTIS also offers outstanding oil
resistance (UL OIL RES I & II) and meets all Tray Cable (UL-1277) and Wind Turbine Tray Cable (UL-2277) requirements.
Applications:
Wind energy, Machine tool, Forestry equipment, Oil & petrochem equipment, Cold temperature storage & packaging facilities.
Technical Data:
Minimum Bend Radius for installation: 5 x cable diameter.
Temperature: •F
or stationary use:
-55ºC to +105ºC
(UL 90ºC)
• For flexible use:
-40ºC to +105ºC
(UL 90ºC).
152
Rated Voltage:
• 600V - TC
• 1000V - TC
Wind Turbine (WTTC)
Color Code:
• Black with white numbers
plus grn/yel ground.
Approvals:
UL:
CSA:
•
•
•
•
•
•
ype TC-ER (Exposed Run), UL WTTC
T
Type MTW or UL AWM, NFPA 79 2007
Oil Res I/II
Class 1, Div.2 per NEC Art. 336, 392, 501
c(UL) Type TC and CIC FT4 -40ºC
CSA-AWM I/II A/B FT4 -40ºC.
Tray Cables
800.633.6339 • www.lapptannehill.com
Tray Cables
ÖLFLEX® CONTROL TM/TM CY, Flexible & Oil Resistant Tray and Machine Cable
with UL/CSA MTW + UL TC-ER/CSA CIC/TC Approval
ÖLFLEX® CONTROL TM-(UL)TYPE TC-ER or MTW 90ºC 600V---CSA AWM FT4 RoHS
Construction: Finely stranded bare copper conductors;
Insulation: Specially blended PVC/nylon insulation; Jacket: Specially formulated PVC jacket.
OLFLEX® CONTROL TM CY-(UL) TYPE TC-ER or MTW 90ºC 600V---CSA AWM FT4 RoHS
Construction: Finely stranded bare copper conductors;
Insulation: Specially blended PVC/nylon insulation, overall foil and tinned copper braid (85% coverage);
Jacket: Specially formulated PVC jacket.
Features:
ÖLFLEX® CONTROL TM is a multi-conductor cable designed for use on machine tool equipment and other industrial machinery conforming to
NFPA 79 2007 wiring norms. ÖLFLEX® CONTROL TM is also UL TC-ER + CSA CIC/TC approved so it can be routed in tray as well.
Applications:
Machine tool machinery, Food & beverage, Processing equipment, Machine wiring for conformance to NFPA 79 2007.
Technical Data:
Minimum bend radius for installation: 6 x cable diameter.
Temperature: •<
-40ºC to +90ºC
Rated Voltage:
• 600V - TC
• 1000V - TC
Wind Turbine (WTTC)
Color Code:
• Conductors are black
printed with white numbers
plus green/yellow ground.
Approvals:
UL:
•
•
•
•
•
CSA:
•
•
Additional:•
U
L Type TC-ER (Exposed Run)
AWM, UL Wet Approval 75ºC
Type MTW, NFPA 79 2007
Class 1, Div.2 per NEC Art. 336, 392, 501
UL Bus Drop-14 AWG & Larger 3c & 4c only**
C(UL) CIC/TC FT4
AWM I/II A/B FT4
Torsion tested for wind market (+/- 150º/m)
ÖLFLEX® CONTROL TM: Flexible and Oil Resistant Tray & Machine Cable
ÖLFLEX® CONTROL TM CY: Shielded Flexible and Oil Resistant Tray & Machine Cable
Tray Cables
800.633.6339 • www.lapptannehill.com
153
Tray Cables
Instrumentation Cable, 300 Volt UL Type PLTC & ITC, 105ºC
Single Pair or Triad, Non-Shielded
Construction: 7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8;
Insulation: Flame-retardant PVC;
Jacket: Sunlight-resistant PVC. A ripcord is applied longitudinally under the jacket to facilitate stripping.
Applications:
For use in instrumentation and process control applications where protection from electrostatic interference
is not required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in
conduits, ducts and cable trays in circuits not exceeding 300 volts. May be used in NEC Class 1, Division 2
hazardous locations.
Catalog
Size
Pair of
No.
AWG
Triad
LTC300-18/1P-7N
P
PLTC300-16/1P-7N
PLTC300-18/1T-7N
PLTC300-16/1T-7N
18
16
18
16
1 Pair
1 Pair
1 Triad
1 Triad
Insulation
Thickness
Mils
Jacket
Thickness
Mils
Overall
Diameter
Inch
Net
Weight
Lbs/Mft
15
15
15
15
35
35
35
35
.25
.27
.26
.29
33
42
41
54
Technical Data:
Flame Tests:
• UL 1581 70,000 BTU/hr flame test.
• CSA FT4 rated.
Temperature: •1
05ºC
Rated Voltage:
• 300V
Color Code:
• ICEA Method 9: black and white for pairs.
• ICEA Method 1: black, white and red for
triads.
Approvals:
•U
L Standard 13
• UL Standard 2250
• NEC Type ITC per Articles 501, 502,
503, and 504
• Approved for Class 2 and Class 3 circuits
per Article 725 of the NEC
Instrumentation Cable, 300 Volt UL Type PLTC & ITC, 105ºC
Single Pair or Triad, Shielded
Construction: 7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8;
Insulation: Flame-retardant PVC;
Jacket: Sunlight-resistant PVC. A ripcord is applied longitudinally under the jacket to facilitate strippping.
Features:
Aluminum-polyemer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.
Applications:
For use in instrumentation and process control applications where protection from electrostatic
interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or
outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 300 volts. May be
used in NEC Class 1, Division 2 hazardous locations.
Technical
Catalog
Size
Pair of
No.
AWG
Triad
LTC300-20/1P-7S
P
PLTC300-18/1P-7S
PLTC300-16/1P-7S
PLTC300-20/1T-7S
PLTC300-18/1T-7S
PLTC300-16/1T-7S
20
18
16
20
18
16
1 Pair
1 Pair
1 Pair
1 Triad
1 Triad
1 Triad
Insulation
Thickness
Mils
Jacket
Thickness
Mils
Overall
Diameter
Inch
Net
Weight
Lbs/Mft
15
15
15
15
15
15
35
35
35
35
35
35
.24
.26
.28
.25
.28
.30
30
37
46
36
46
62
Temperature: •1
05ºC
Rated Voltage:
• 300V
Color Code:
• ICEA Method 9: black and white for pairs.
• ICEA Method 1: black, white and red for
triads.
Approvals:
•U
L Standard 13
• UL Standard 2250
• NEC Type ITC per Articles 501, 502,
503, and 504
• Approved for Class 2 and Class 3 circuits
per Article 725 of the NEC
Not finding what you are looking for?
Please contact us at sales@lapptannehill.com,
or visit our website at: www.lapptannehill.com
154
Data:
Flame Tests:
• UL 1581 70,000 BTU/hr flame test.
• CSA FT4 rated.
Tray Cables
800.633.6339 • www.lapptannehill.com
Tray Cables
Instrumentation Cable, 300 Volt UL Type PLTC & ITC, 105ºC
Multiple Pairs, Overall Shield
Construction: 7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8;
Insulation: Flame-retardant PVC;
Jacket: Sunlight-resistant PVC. A ripcord is applied longitudinally under the jacket to facilitate stripping.
Features:
Aluminum-polyemer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.
Applications:
For use in instrumentation and process control applications where protection from electrostatic interference
is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in
conduits, ducts and cable trays in circuits not exceeding 300 volts. May be used in NEC Class 2, Division 2
hazardous locations.
Catalog
Size
No.
AWG
PLTC300-20/2P-7S
PLTC300-20/4P-7S
PLTC300-20/8P-7S
PLTC300-20/12P-7S
PLTC300-20/16P-7S
PLTC300-20/24P-7S
PLTC300-20/36-7S
PLTC300-20/50P-7S
PLTC300-18/2P-7S
PLTC300-18/4P-7S
PLTC300-18/8P-7S
PLTC300-18/12P-7S
PLTC300-18/16P-7S
PLTC300-18/24P-7S
PLTC300-18/36P-7S
PLTC300-18/50P-7S
PLTC300-16/2P-7S
PLTC300-16/4-7S
PLTC300-16/8P-7S
PLTC300-16/12P-7S
PLTC300-16/16-7S
PLTC300-16/24P-7S
PLTC300-16/36P-7S
PLTC300-16/50P-7S
Number
of
Pairs
Insulation
Thickness
Mils
20 2
20 4
20 8
20
12
20
16
20
24
20
36
20
50
18 2
18 4
18 8
18
12
18
16
18
24
18
36
18
50
16 2
16 4
16 8
16
12
16
16
16
24
16
36
16
50
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
Jacket
Thickness
Mils
Overall
Diameter
Inch
Net
Weight
Lbs/Mft
40 .34 52
40 .40 78
50 .52 143
50 .61 195
60 .74 261
60 .82 356
70 .95 513
70
1.17 692
40 .37 64
50 .47 113
50 .58 187
60 .69 271
60 .81 341
60 .90 479
70
1.06 695
70
1.29 930
50 .44 94
50 .52 148
60 .66 264
60 .77 367
70
1.01 503
70
1.04 683
70
1.19 970
80
1.60
1378
Technical Data:
Flame Tests:
• UL 1581 70,000 BTU/hr flame test.
• CSA FT4 rated.
Temperature: •1
05ºC
Rated Voltage:
• 300V
Color Code:
• ICEA Method 9: black and white pairs
with printed number.
Approvals:
•U
L Standard 13
• UL Standard 2250
• NEC Type ITC per Articles 501, 502,
503, and 504
• Approved for Class 2 and Class 3 circuits
per Article 725 of the NEC
Specifications subject to change. For complete specifications and availability visit www.lapptannehill.com
Tray Cables
800.633.6339 • www.lapptannehill.com
155
Tray Cables
Instrumentation Cable, 300 Volt UL Type PLTC & ITC, 105ºC
Multiple Pairs, Individual and Overall Shield
Construction: 7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8;
Insulation: Flame-retardant PVC;
Jacket: Sunlight-resistant PVC. A ripcord is applied longitudinally under the jacket to facilitate stripping.
Features:
Individual Shield: Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper
drain wire.
Overall Shield: Aluminum-polyemer tape providing 100% coverage with a flexible 7-strand tinned copper
drain wire.
Applications:
For use in instrumentation and process control applications where superior protection from electrostatic
interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors,
aerially, in conduits, ducts and cable trays in circuits not exceeding 300 volts. May be used in NEC Class
1, Divison 2 hazardous locations.
Catalog
Size
No.
AWG
PLTC300-20/2P-7SPOS
PLTC300-20/4P-7SPOS
PLTC300-20/8P-7SPOS
PLTC300-20/12P-7SPOS
PLTC300-20/16P-7SPOS
PLTC300-20/24P-7SPOS
PLTC300-20/36P-7SPOS
PLTC300-20/50P-7SPOS
PLTC300-18/2P-7SPOS
PLTC300-18/4P-7SPOS
PLTC300-18/8P-7SPOS
PLTC300-18/12P-7SPOS
PLTC300-18/16P-7SPOS
PLTC300-18/24P-7SPOS
PLTC300-18/36P-7SPOS
PLTC300-18/50P-7SPOS
Number
of
Pairs
20 2
20 4
20 8
20
12
20
16
20
24
20
36
20
50
18 2
18 4
18 8
18
12
18
16
18
24
18
36
18
50
Insulation
Thickness
Mils
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
Jacket
Thickness
Mils
Overall
Diameter
Inch
Net
Weight
Lbs/Mft
40 .36 61
50 .46 110
50 .58 182
60 .71 267
60 .81 315
70 .97 492
70
1.11 685
70
1.33 768
40 .40 76
50 .50 134
50 .63 226
60 .78 332
60 .89 374
70
1.08 619
70
1.23 869
80
1.49
1047
Technical Data:
Flame Tests:
• UL 1581 70,000 BTU/hr flame test.
• CSA FT4 rated.
Temperature: •1
05ºC
Rated Voltage:
• 300V
Color Code:
• ICEA Method 9: black and white pairs
with printed number.
Approvals:
•U
L Standard 13
• UL Standard 2250
• NEC Type ITC per Articles 501, 502,
503, and 504
• Approved for Class 2 and Class 3 circuits
per Article 725 of the NEC
Check out our complete inventory of products at www.lapptannehill.com
156
Tray Cables
800.633.6339 • www.lapptannehill.com
Tray Cables
Instrumentation Cable, 300 Volt UL Type PLTC & ITC, 105ºC
Multiple Pairs, Individual and Overall Shield
Construction: 7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8;
Insulation: Flame-retardant PVC;
Jacket: Sunlight-resistant PVC. A ripcord is applied longitudinally under the jacket to facilitate stripping.
Features:
Individual Shield: Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned
copper drain wire.
Overall Shield: Aluminum-polyemer tape providing 100% coverage with a flexible 7-strand tinned copper
drain wire.
Applications:
For use in instrumentation and process control applications where superior protection from electrostatic
interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or
outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 300 volts. May be used in
NEC Class 1, Divison 2 hazardous locations.
Catalog
Size
No.
AWG
PLTC300-16/2P-7SPOS
PLTC300-16/4P-7SPOS
PLTC300-16/8P-7SPOS
PLTC300-16/12P-7SPOS
PLTC300-16/16P-7SPOS
PLTC300-16/24P-7SPOS
PLTC300-16/36P-7SPOS
PLTC300-16/50P-7SPOS
Number
of
Pairs
16 2
16 4
16 8
16
12
16
16
16
24
16
36
16
50
Insulation
Thickness
Mils
15
15
15
15
15
15
15
15
Jacket
Thickness
Mils
Overall
Diameter
Inch
Net
Weight
Lbs/Mft
50 .47 107
50 .55 178
60 .73 323
60 .87 456
70
1.02 529
70
1.21 860
80
1.40
1250
80
1.68
1453
Technical Data:
Flame Tests:
• UL 1581 70,000 BTU/hr flame test.
• CSA FT4 rated.
Temperature: •1
05ºC
Rated Voltage:
• 300V
Color Code:
• ICEA Method 9: black and white pairs
with printed number.
Approvals:
•U
L Standard 13
• UL Standard 2250
• NEC Type ITC per Articles 501, 502,
503, and 504
• Approved for Class 2 and Class 3 circuits
per Article 725 of the NEC
Specifications subject to change. For complete specifications and availability visit www.lapptannehill.com
Tray Cables
800.633.6339 • www.lapptannehill.com
157
Tray Cables
Instrumentation Cable, 300 Volt UL Type PLTC & ITC, 105ºC
Multiple Triads, Individual and Overall Shield
Construction: 7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8;
Insulation: Flame-retardant PVC;
Jacket: Sunlight-resistant PVC. A ripcord is applied longitudinally under the jacket to facilitate stripping.
Features:
Individual Shield: Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned
copper drain wire.
Overall Shield: Aluminum-polymer tape providing 100% coverage with a flexible 70 strand tinned
copper drain wire.
Applications:
For use in instrumentation and process control applications where superior protection from electrostatic
interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or
outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 300 volts. May be used in
NEC Class 1, Division 2 hazardous locations.
Catalog
Size
No.
AWG
PLTC300-20/4T-7STOS
PLTC300-20/8T-7STOS
PLTC300-20/12T-7STOS
PLTC300-20/16T-7STOS
PLTC300-20/24T-7STOS
PLTC300-20/36T-7STOS
PLTC300-18/4T-7STOS
PLTC300-18/8T-7STOS
PLTC300-18/12-7STOS
PLTC300-18/16T-7STOS
PLTC300-18/24T-7STOS
PLTC300-16/4T-7STOS
PLTC300-16/8T-7STOS
PLTC300-16/12T-7STOS
PLTC300-16/16T-7STOS
PLTC300-16/24T-7STOS
Number
of
Triads
20 4
20 8
20
12
20
16
20
24
20
36
18 4
18 8
18
12
18
16
18
24
16 4
16 8
16
12
16
16
16
24
Insulation
Thickness
Mils
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
Jacket
Thickness
Mils
Overall
Diameter
Inch
Net
Weight
Lbs/Mft
50 .50 136
50 .65 214
60 .78 338
60 .86 428
70
1.10 591
70
1.22 887
50 .54 134
60 .74 293
60 .86 332
70 .97 420
70
1.21 768
50 .61 229
60 .82 395
70 .98 621
70
1.09 794
80
1.39
1085
Technical Data:
Flame Tests:
• UL 1581 70,000 BTU/hr flame test.
• CSA FT4 rated.
Temperature: •1
05ºC
Rated Voltage:
• 300V
Color Code:
• ICEA Method 9: black and white pairs
with printed number.
Approvals:
•U
L Standard 13
• UL Standard 2250
• NEC Type ITC per Articles 501, 502,
503, and 504
• Approved for Class 2 and Class 3 circuits
per Article 725 of the NEC
Not finding what you are looking for?
Please contact us at sales@lapptannehill.com, or visit our website at: www.lapptannehill.com
158
Tray Cables
800.633.6339 • www.lapptannehill.com
Tray Cables
Instrumentation Cable, 600 Volt UL Type TC-ER, 90ºC
Multiple Pairs, Overall Shield
Construction: 7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8;
Insulation: Flame-retardant PVC per UL Standard 62 for Type TFN wire. Insulation Jacket: Clear
nylon per UL Standard 62 for Type TFN wire;
Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the
jacket to facilitate stripping. Clear nylon per UL Standard 62 for Type TFN wire.
Features:
Overall Shield: Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned
copper drain wire.
Applications:
For use in instrumentation and process control applications where superior protection from
electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation
indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 300 volts.
May be used in NEC Class 1, Divison 2 hazardous locations.
Number
Catalog
Size
of
No.
AWG
Pairs
TRAY600-18/2P-7S
TRAY600-18/4P-7S
TRAY600-18/8P-7S
TRAY600-18/12P-7S
TRAY600-18/16P-7S
TRAY600-18/24P-7S
TRAY600-18/36P-7S
TRAY600-18/50P-7S
TRAY600-16/2P-7S
TRAY600-16/3P-7S
TRAY600-16/4P-7S
TRAY600-16/8P-7S
TRAY600-16/12P-7S
TRAY600-16/16P-7S
TRAY600-16/24P-7S
TRAY600-16/36P-7S
TRAY600-16/50P-7S
18 2
18 4
18 8
18
12
18
16
18
24
18
36
18
50
16 2
16 3
16 4
16 8
16
12
16
16
16
24
16
36
16
50
PVC
Insulation
Thickness
Mils
Nylon
Jacket
Thickness
Mils
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Overall
Jacket
Overall
Thickness
Diameter
Mils
Inch
Net
Weight
Lbs/Mft
45 .41 70
45 .49 118
60 .65 212
60 .76 302
80 .89 374
80
1.03 572
80
1.18 796
80
1.44
1046
45 .45 89
45 .52 121
45 .57 150
60 .75 283
60 .88 389
80
1.03 540
80
1.21 742
80
1.40
1038
80
1.61
1436
Technical Data:
Flame Tests:
• UL 1581 70,000 BTU/hr flame test.
Temperature: •9
0ºC
Rated Voltage:
• 600V
Color Code:
• ICEA Method 9: black and
white pairs with printed
number.
Approvals:
•N
EC Type TC for Class I
Division 2 areas per Articles
336, 392, and 501, and for
Class 1 circuits per NEC
Article 725
• NEC Type NPFL for Non
Power Limited Fire
Please contact your sales representative for detailed information at sales@lapptannehill.com
Tray Cables
800.633.6339 • www.lapptannehill.com
159
Tray Cables
Instrumentation Cable, 600 Volt UL Type TC-ER, 90ºC
Multiple Pairs, Individual and Overall Shield
Construction: 7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8;
Insulation: Flame-retardant PVC per UL Standard 62 for Type TFN wire. Clear nylon per UL
Standard 62 for Type TFN wire;
Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the
jacket to facilitate stripping.
Features:
Individual Shield: Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned
copper drain wire.
Overall Shield: Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned
copper drain wire.
Applications:
For use in instrumentation and process control applications where superior protection from
electrostatic inteference is required. UL listed as Type TC and approved for installation indoors or
outdoors, aerially, in conduits, ducts, cable trays and direct burial in circuits not exceeding 600 volts.
Maybe used in NEC Class1, Division 2 hazardous locations.
Number
Catalog
Size
of
No.
AWG
Pairs
TRAY600-18/2P-7SPOS
TRAY600-18/4P-7SPOS
TRAY600-18/8P-7SPOS
TRAY600-18/12P-7SPOS
TRAY600-18/16P-7SPOS
TRAY600-18/24P-7SPOS
TRAY600-18/36P-7SPOS
TRAY600-18/50P-7SPOS
TRAY600-16/2P-7SPOS
TRAY600-16/3P-7SPOS
TRAY600-16/4P-7SPOS
TRAY600-16/6P-7SPOS
TRAY600-16/8P-7SPOS
TRAY600-16/12P-7SPOS
TRAY600-16/16P-7SPOS
TRAY600-16/24P-7SPOS
TRAY600-16/36P-7SPOS
TRAY600-16/50P-7SPOS
18 2
18 4
18 8
18
12
18
16
18
24
18
36
18
50
16 2
16 3
16 4
16 6
16 8
16
12
16
16
16
24
16
36
16
50
PVC
Insulation
Thickness
Mils
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
Nylon
Jacket
Thickness
Mils
Overall
Jacket
Overall
Thickness Diameter
Mils
Inch
Technical Data:
Flame Tests:
• UL 1581 70,000 BTU/hr flame test.
Net
Weight
Lbs/Mft
4 45 .44 82
4 45 .52 146
4 60 .71 279
4 60 .85 391
4 80
1.05 494
4 80
1.20 752
4 80
1.37
1053
4 80
1.71
1300
4 45 .48 105
4 45 .56 136
4 60 .63 207
4 60 .77 257
4 60 .81 349
4 80
1.11 528
4 80
1.56 623
4 80
1.39 944
4 80
1.59
1331
4
110
1.96
1731
Temperature: •9
0ºC
Rated Voltage:
• 600V
Color Code:
• ICEA Method 9: black and
white pairs with printed
number.
Approvals:
•N
EC Type TC for Class I NEC
Type TC for Class I Division
2 areas per Articles 336, 392
and 501, and for Class 1
circuits per NEC Article 725
• NEC Type NPFL for Non
Power Limited Fire Protective
Signaling circuits per NEC
Article 760
Not finding what you are looking for?
Please contact us at sales@lapptannehill.com, or visit our website at: www.lapptannehill.com
160
Tray Cables
800.633.6339 • www.lapptannehill.com
Tray Cables
Instrumentation Cable, 600 Volt UL Type TC-ER, 90ºC
Multiple Pairs, Individual and Overall Shield
Construction: 7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8;
Insulation: Flame-retardant PVC per UL Standard 83 for Type THHN or THWN-2 wire. Insulation
jacket: Clear nylon per UL Standard 83 for Type THHN or THWN-2 wire;
Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the
jacket to facilitate stripping.
Features:
Individual Shield: Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned
copper drain wire.
Overall Shield: Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned
copper drain wire.
Applications:
For use in instrumentation and process control applications where superior protection from
electrostatic interference is required. UL listed as Type TC and approved for installation indoors or
outdoors, aerially, in conduits, ducts, cable trays and direct burial in circuits not exceeding 600 volts.
May be used in NEC Class 1, Division 2 hazardous locations. UL approved for NEC continuous
operation at 75ºC in wet locations, 90ºC in dry locations, 130ºC for emergency overload conditions,
and 250ºC for short circuit conditions.
Number
Catalog
Size
of
No.
AWG
Pairs
TRAY600-14/2P-7SPOS
TRAY600-14/4P-7SPOS
TRAY600-14/8P-7SPOS
TRAY600-14/12P-7SPOS
TRAY600-14/24P-7SPOS
14 2
14 4
14 8
14
12
14
24
PVC
Insulation
Thickness
Mils
Nylon
Jacket
Thickness
Mils
15
15
15
15
15
4
4
4
4
4
Overall
Jacket
Overall
Thickness
Diameter
Mils
Inch
Net
Weight
Lbs/Mft
45 .57 156
60 .73 285
60 .93 520
80
1.16 788
80
1.58
1445
Technical Data:
Flame Tests:
• UL 1581 70,000 BTU/hr flame test.
Temperature: •9
0ºC
Rated Voltage:
• 600V
Color Code:
• ICEA Method 9: black and white
pairs with printed number.
Approvals:
•N
EC Type TC for Class I Division
2 areas per Articles 336, 392 and
501, and for Class 1 circuits per
NEC Article 725
• NEC Type NPFL for Non Power
Limited Fire Protective Signaling
circuits per NEC Article 760.0
Check out our complete inventory of products at www.lapptannehill.com
Tray Cables
800.633.6339 • www.lapptannehill.com
161
Tray Cables
Instrumentation Cable, 600 Volt UL Type TC-ER, 90ºC
Multiple Triads, Individual and Overall Shield
Construction: 7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8;
Insulation: Flame-retardant PVC per UL Standard 62 for Type TFN wire. Insulation jacket: Clear
nylon per UL Standard 62 for Type TFN wire;
Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the
jacket to facilitate stripping.
Features:
Individual Shield: Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned
copper drain wire.
Overall Shield: Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned
copper drain wire.
Applications:
For use in instrumentation and process control applications where superior protection from
electrostatic interference is required. UL listed as Type TC and approved for installation indoors or
outdoors, aerially, in conduits, ducts, cable trays and direct burial in circuits not exceeding 600 volts.
May be used in NEC Class 1, Divison 2 hazardous locations. UL approved for NEC continuous
operations at 75ºC in wet locations, 90ºC in dry locations, 130ºC for emergency overload conditions,
and 250ºC for short circuit conditions.
Number
Catalog
Size
of
No.
AWG
Triads
TRAY600-18/4T-7STOS
TRAY600-18/8T-7STOS
TRAY600-18/12T-7STOS
TRAY600-18/24T-7STOS
TRAY600-16/4T-7STOS
TRAY600-16/8T-7STOS
TRAY600-16/12T-7STOS
TRAY600-16/16T-7STOS
TRAY600-16/24T-7STOS
18 4
18 8
18
12
18
24
16 4
16 8
16
12
16
16
16
24
PVC
Insulation
Thickness
Mils
Nylon
Jacket
Thickness
Mils
15
15
15
15
15
15
15
15
15
4
4
4
4
4
4
4
4
4
Overall
Jacket
Overall
Thickness
Diameter
Mils
Inch
Technical Data:
Flame Tests:
• UL 1581 70,000 BTU/hr flame test.
Temperature: •9
0ºC
Net
Weight
Lbs/Mft
60 .61 207
60 .78 355
80 .98 538
80
1.33 971
60 .67 233
60 .90 401
80
1.08 607
80
1.27 838
80
1.48
1100
Rated Voltage:
• 600V
Color Code:
• ICEA Method 1: black, white and
red triads with printed number.
Approvals:
•N
EC Type TC for Class 1
Division 2 areas per Articles
336,392 and 501, and for Class 1
circuits per NEC Article 725
• NEC Type NPFL for Non Power
Limited Fire Protective Signaling
circuits per NEC Article 760
Specifications subject to change. For complete specifications and availability visit www.lapptannehill.com
162
Tray Cables
800.633.6339 • www.lapptannehill.com
Tray Cables
Tray Cable-Control Cable, 600 Volt UL Type TC-ER, TFN Insulation
PVC Jacket, Copper Conductors
Construction: Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8;
Insulation: Flame-retardant PVC per UL Standard 62 for Type TFN wire. Insulation jacket: clear
nylon per UL Standard 62 for Type TFN wire;
Jacket: Sunlight-resistant PVC per UL Standard 1277.
Features:
600 Volt UL Type TC, TFN Insulation, PVC Jacket, Copper Conductors
Applications:
General purpose cable for use in power, control and lighting circuits in a broad range of commercial
and industrial applications. Approved for continuous operation at 90ºC in dry locations, installation
indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding
600 volts. May be used in NEC Class I and II, Divison 2 hazardous locations.
Number
Number
Insulation
Catalog
Size
of
of
Thickness
No.
AWG
Conductors Strands
Mils
TRAY600-18/2-7N*
TRAY600-18/3-7N
TRAY600-18/4-7N
TRAY600-18/5-7N
TRAY600-18/6-7N
TRAY600-18/7-7N
TRAY600-18/8-7N
TRAY600-18/9-7N
TRAY600-18/10-7N
TRAY600-18/12-7N
TRAY600-18/15-7N
TRAY600-18/19-7N
TRAY600-18/25-7N
TRAY600-18/30-7N
TRAY600-18/37-7N
*Flat construction
18 2
18 3
18 4
18 5
18 6
18 7
18 8
18 9
18
10
18
12
18
15
18
19
18
25
18
30
18
37
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
Number
Number
Insulation
Catalog
Size
of
of
Thickness
No.
AWG
Conductors Strands
Mils
TRAY600-16/2-7N*
TRAY600-16/3-7N
TRAY600-16/4-7N
TRAY600-16/5-7N
TRAY600-16/6-7N
TRAY600-16/7-7N
TRAY600-16/8-7N
TRAY600-16/9-7N
TRAY600-16/10-7N
TRAY600-16/12-7N
TRAY600-16/15-7N
TRAY600-16/16-7N
TRAY600-16/19-7N
TRAY600-16/20-7N
TRAY600-16/25-7N
TRAY600-16/37-7N
TRAY600-16/50-7N
*Flat construction
16 2
16 3
16 4
16 5
16 6
16 7
16 8
16 9
16
10
16
12
16
15
16
16
16
19
16
20
16
25
16
37
16
50
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
Nylon
Jacket
Thickness
Mils
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Nylon
Jacket
Thickness
Mils
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Overall
Jacket
Overall
Thickness
Diameter
Mils
Inch
45
45
45
45
45
45
45
45
45
45
45
60
60
60
60
.19 x .28 33
.28 43
.31 52
.33 62
.36 72
.37 79
.38 89
.41 104
.45 111
.46 127
.51 157
.57 202
.65 258
.69 300
.74 360
Overall
Jacket
Overall
Thickness
Diameter
Mils
Inch
45
45
45
45
45
45
45
45
45
45
60
60
60
60
60
80
80
Net
Weight
Lbs/Mft
Technical Data:
Flame Tests:
• IEEE 383 70,000 BTU/hr flame test.
• ICEA 210,000 BTU/hr flame test.
Temperature: •9
0ºC
Rated Voltage:
• 600V
Color Code:
• ICEA Method 1, Table K-2
Approvals:
•U
L Type TC per Article 336 of
the NEC
• Approved for Class 1 remotecontrol and signaling circuits per
Article 725 of the NEC
Net
Weight
Lbs/Mft
.20 x .30 42
.31 55
.34 69
.36 83
.39 96
.39 106
.39 122
.43 138
.46 149
.51 174
.60 229
.60 241
.63 275
.66 291
.72 355
.82 498
1.01 703
Tray Cables
800.633.6339 • www.lapptannehill.com
163
Tray Cables
Tray Cable-Control Cable, 600 Volt UL Type TC-ER, THHN or THWN Insulation
PVC Jacket
Construction: Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8;
Insulation: Flame-retardant PVC per UL Standard 83 for Type THHN or THWN wire. Insulation
jacket: clear nylon per UL Standard 83 for Type THHN or THWN wire;
Jacket: Sunlight-resistant PVC per UL Standard 1277.
Features:
600 Volt UL Type TC, THHN or THWN Insulation, PVC Jacket, Copper Conductors
Applications:
General purpose cable for use in power, control and lighting circuits in a broad range of commercial
and industrial applications. Approved for continuous operation at 90ºC in dry locations, installation
indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding
600 volts. May be used in NEC Class I and II, Divison 2 hazardous locations.
Number
Number
Insulation
Catalog
Size
of
of
Thickness
No.
AWG
Conductors Strands
Mils
TRAY600-14/2-7N*
TRAY600-14/3-7N
TRAY600-14/4-7N
TRAY600-14/5-7N
TRAY600-14/6-7N
TRAY600-14/7-7N
TRAY600-14/9-7N
TRAY600-14/10-7N
TRAY600-14/12-7N
TRAY600-14/16-7N
TRAY600-14/19-7N
TRAY600-14/20-7N
TRAY600-14/25-7N
TRAY600-14/30-7N
TRAY600-14/37-7N
TRAY600-14/40-7N
TRAY600-14/50-7N
TRAY600-14/60-7N
*Flat construction
14 2
14 3
14 4
14 5
14 6
14 7
14 9
14
10
14
12
14
16
14
19
14
20
14
25
14
30
14
37
14
40
14
50
14
60
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
Nylon
Jacket
Thickness
Mils
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Overall
Jacket
Overall
Thickness
Diameter
Mils
Inch
45
45
45
45
45
45
45
60
60
60
60
60
80
80
80
80
80
80
Net
Weight
Lbs/Mft
.22 x .33 62
.35 80
.38 99
.41 118
.45 140
.45 153
.52 196
.60 230
.61 267
.68 343
.71 396
.75 423
.83 511
.93 636
.98 766
1.01 840
1.17 1043
1.21 1200
Technical Data:
Flame Tests:
• IEEE 383 70,000 BTU/hr flame test.
• ICEA 210,000 BTU/hr flame test.
Temperature: •9
0ºC
Rated Voltage:
• 600V
Color Code:
• ICEA Method 1, Table K-2.
Approvals:
•U
L Type TC per Article 336 of
the NEC
• Approved for Class 1 remotecontrol and signaling circuits
per Article 725 of the NEC.
Please contact your sales representative for detailed information at sales@lapptannehill.com
164
Tray Cables
800.633.6339 • www.lapptannehill.com
Tray Cables
Tray Cable-Control Cable, 600 Volt UL Type TC-ER, THHN or THWN Insulation
PVC Jacket
Construction: Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8;
Insulation: Flame-retardant PVC per UL Standard 83 for Type THHN or THWN wire. Insulation jacket:
Clear nylon per UL Standard 83 for Type THHN or THWN wire;
Jacket: Sunlight-resistant PVC per UL Standard 1277.
Features: 600 Volt UL Type TC, TFN Insulation, PVC Jacket, Copper Conductors
Applications:
General purpose cable for use in power, control and lighting circuits in a broad range of commercial and
industrial applications. Approved for installation indoors or outdoors, aerially, in conduits, ducts, cable trays
or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Divison 2 hazardous
locations. UL approved for use in continuous operation at 75ºC in wet locations, 90ºC in dry locations,
130ºC for emergency overload conditions, and 250ºC for short circuit conditions.
Number
Number
Insulation
Catalog
Size
of
of
Thickness
No.
AWG
Conductors Strands
Mils
TRAY600-12/2-7N*
TRAY600-12/3-7N
TRAY600-12/4-7N
TRAY600-12/5-7N
TRAY600-12/7-7N
TRAY600-12/9-7N
TRAY600-12/10-7N
TRAY600-12/12-7N
TRAY600-12/15-7N
TRAY600-12/16-7N
TRAY600-12/19-7N
TRAY600-12/20-7N
TRAY600-12/25-7N
TRAY600-12/30-7N
TRAY600-12/37-7N
*Flat construction
12 2
12 3
12 4
12 5
12 7
12 9
12
10
12
12
12
15
12
16
12
19
12
20
12
25
12
30
12
37
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
Number
Number
Insulation
Catalog
Size
of
of
Thickness
No.
AWG
Conductors Strands
Mils
TRAY600-10/2-7N*
TRAY600-10/3-7N
TRAY600-10/4-7N
TRAY600-10/5-7N
TRAY600-10/6-7N
TRAY600-10/7-7N
TRAY600-10/9-7N
TRAY600-10/12-7N
TRAY600-10/16-7N
TRAY600-10/19-7N
*Flat construction
10 2
10 3
10 4
10 5
10 6
10 7
10 9
10
12
10
16
10
19
7
7
7
7
7
7
7
7
7
7
20
20
20
20
20
20
20
20
20
20
Nylon
Jacket
Thickness
Mils
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
Nylon
Jacket
Thickness
Mils
4
4
4
4
4
4
4
4
4
4
Overall
Jacket
Overall
Thickness
Diameter
Mils
Inch
45
45
45
45
45
60
60
60
60
60
60
80
80
80
80
.24 x .37 77
.39 110
.42 138
.46 165
.50 216
.62 297
.67 324
.69 378
.76 468
.76 488
.80 568
.89 642
.99 775
1.03 910
1.14 1105
Overall
Jacket
Overall
Thickness
Diameter
Mils
Inch
45
45
60
60
60
60
60
80
80
80
Net
Weight
Lbs/Mft
.27 x .44
.45
.50
.58
.63
.63
.73
.86
.97
1.02
Technical Data:
Flame Tests:
• IEEE 383 70,000 BTU/hr flame test.
• ICEA 210,000 BTU/hr flame test.
Temperature: •9
0ºC
Rated Voltage:
• 600V
Color Code:
• ICEA Method 1, Table K-2
Approvals:
•U
L Type TC per Article 336 of
the NEC
• Approved for Class 1 remotecontrol and signaling circuits
per Article 725 of the NEC
Net
Weight
Lbs/Mft
131
169
231
276
329
361
465
647
817
920
Not finding what you are looking for?
Please contact us at sales@lapptannehill.com, or visit our website at: www.lapptannehill.com
Tray Cables
800.633.6339 • www.lapptannehill.com
165
Tray Cables
Tray Cable-Control Cable, 600 Volt UL Type TC-ER, THHN or THWN Insulation
PVC Jacket
Construction: Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8;
Insulation: Flame-retardant PVC per UL Standard 83 for Type THHN or THWN wire.
Jacket: Sunlight-resistant PVC per UL Standard 1277.
Features:
Insulation jacket: clear nylon per UL Standard 83 for Type THHN or THWN wire
Grounding Conductor: soft bare annealed copper per ASTM B-3, Class B stranding per ASTM
B-8 sized in accordance with UL Standard 1277.
600 Volt, UL Type TC, THHN or THWN Insulation, PVC Jacket, Copper Conductors.
Applications:
General purpose cable for use in primary power and feeder circuits in a broad range of
commercial and industrial applications. Approved for installation indoors or outdoors, aerially,
in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in
NEC Class I and II, Divison 2 hazardous locations. UL approved for use in continuous operation
at 75ºC in wet locations, 90ºC in dry locations, 130ºC for emergency overload conditions, and
250ºC for short circuit conditions.
Number
Number
Insulation
Catalog
Size
of
of
Thickness
No.
AWG
Conductors Strands
Mils
TRAY600-8/3-7N
TRAY600-8/4-7N
TRAY600-6/3-7N
TRAY600-6/4-7N
TRAY600-4/3-7N
TRAY600-4/4-7N
TRAY600-2/3-7N
TRAY600-2/4-7N
TRAY600-1/3-19N
8
8
6
6
4
4
2
2
1
3 7
4 7
3 7
4 7
3 7
4 7
3 7
4 7
3
19
Nylon
Jacket
Thickness
Mils
30
30
30
30
40
40
40
40
50
5
5
5
5
6
6
6
6
7
Size
Number
Number
Insulation
Catalog
AWG/
of
of
Thickness
No.
kcmil
Conductors
Strands
Mils
TRAY600-1/0-3-19N
TRAY600-1/0-4-19N
TRAY600-2/0-3-19N
TRAY600-2/0-4-19N
TRAY600-3/0-3-19N
TRAY600-3/0-4-19N
TRAY600-4/0-3-19N
TRAY600-4/0-4-19N
TRAY600-250/3-37N
TRAY600-250/4-37N
TRAY600-350/3-37N
TRAY600-350/4-37N
TRAY600-500/3-37N
TRAY600-500/4-37N
TRAY600-750/3-37N
166
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
250
250
350
350
500
500
750
3
4
3
4
3
4
3
4
3
4
3
4
3
4
3
19
19
19
19
19
19
19
19
37
37
37
37
37
37
37
50
50
50
50
50
50
50
50
60
60
60
60
60
60
60
Overall
Jacket
Overall
Thickness
Diameter
Mils
Inch
Technical Data:
Flame tests:
• IEEE 383 70,000 BTU/hr flame test.
• ICEA 210,000 BRU/hr flame test.
Temperature: •9
0ºC
Net
Weight
Lbs/Mft
Rated Voltage:
• 600V
60 .58 220
60 .61 286
60 .69 386
60 .76 505
60 .89 630
80 .97 828
80
1.03 930
80
1.13 1213
80
1.15 1252
Nylon
Jacket
Thickness
Mils
7
7
7
7
7
7
7
7
8
8
8
8
8
8
9
Ground
Wire
Size
AWG
Overall
Jacket
Thickness
Mils
6 80
6 80
6 80
6 80
4 80
4 80
4 80
4 80
3
110
3
110
3
110
3
110
2
110
1
110
1
110
Color Code:
• ICEA Method 4
Approvals:
•U
L Type TC per
Article 336 of the NEC
Overall
Diameter
Inch
Net
Weight
Lbs/Mft
1.22
1.34
1.32
1.45
1.42
1.58
1.54
1.77
1.75
1.94
1.97
2.18
2.26
2.49
2.82
1423
1832
1718
2223
2131
2756
2592
3457
3123
4046
4204
5469
5792
7556
9060
Tray Cables
800.633.6339 • www.lapptannehill.com
Tray Cables
Tray Cable-Shielded Control Cable, 600 Volt UL Type TC-ER, TFN Insulation
PVC Jacket
Construction: Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8;
Insulation: Flame-retardant PVC per UL Standard 62 for Type TFN wire;
Jacket: Sunlight-resistant PVC per UL Standard 1277.
Features:
Insulation jacket: clear nylon per UL Standard 62 for Type TFN wire.
Overall Shield: Aluminum-polymer tape providing 100% coverage with a flexible 7-strand
tinned copper drain wire.
Applications:
General purpose cable for use where shielding from electrostatic interference is required in power,
control and lighting circuits in a broad range of commercial and industrial applications. Approved for
continuous operation at 90ºC in dry locations, installation indoors or outdoors, aerially, in conduits,
ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and
II, Division 2 hazardous locations.
Number
Number
Insulation
Catalog
Size
of
of
Thickness
No.
AWG
Conductors Strands
Mils
TRAY600-18/2-7S
TRAY600-18/3-7S
TRAY600-18/4-7S
TRAY600-18/5-7S
TRAY600-18/6-7S
TRAY600-18/7-7S
TRAY600-18/8-7S
TRAY600-18/12-7S
TRAY600-18/19-7S
TRAY600-18/37-7S
18 2
18 3
18 4
18 5
18 6
18 7
18 8
18
12
18
19
18
37
7
7
7
7
7
7
7
7
7
7
15
15
15
15
15
15
15
15
15
15
Number
Number
Insulation
Catalog
Size
of
of
Thickness
No.
AWG
Conductros Strands
Mils
TRAY600-16/2-7S
TRAY600-16/3-7S
TRAY600-16/4-7S
TRAY600-16/5-7S
TRAY600-16/6-7S
TRAY600-16/7-7S
TRAY600-16/8-7S
TRAY600-16/9-7S
TRAY600-16/10-7S
TRAY600-16/12-7S
TRAY600-16/19-7S
TRAY600-16/25-7S
TRAY600-16/37-7S
16 2
16 3
16 4
16 5
16 6
16 7
16 8
16 9
16
10
16
12
16
19
16
25
16
37
7
7
7
7
7
7
7
7
7
7
7
7
7
15
15
15
15
15
15
15
15
15
15
15
15
15
Nylon
Jacket
Thickness
Mils
4
4
4
4
4
4
4
4
4
4
Nylon
Jacket
Thickness
Mils
4
4
4
4
4
4
4
4
4
4
4
4
4
Overall
Jacket
Overall
Thickness
Diameter
Mils
Inch
45
45
45
45
45
45
45
45
60
60
.27 34
.28 43
.31 52
.33 62
.36 72
.36 79
.38 89
.46
127
.57
202
.74
360
Overall
Jacket
Overall
Thickness
Diameter
Mils
Inch
45
45
45
45
45
45
45
45
45
45
60
60
80
Net
Weight
Lbs/Mft
Technical Data:
Flame Tests:
• IEEE 383 70,000 BTU/hr flame test.
• ICEA 210,000 BTU/hr flame test.
Temperature: •9
0ºC
Rated Voltage:
• 600V
Color Code:
• ICEA Method 1, Table K-2
Approvals:
•U
L Type TC per Article 336 of
the NEC
• Approved for Class 1 remotecontrol and signaling circuits
per Article 725 of the NEC
Net
Weight
Lbs/Mft
.29 43
.31 55
.34 69
.36 83
.39 96
.39
106
.43
122
.46
138
.49
149
.51
174
.63
275
.72
355
.82
498
Specifications subject to change. For complete specifications and availability visit www.lapptannehill.com
Tray Cables
800.633.6339 • www.lapptannehill.com
167
Tray Cables
Color Code Charts
ICEA/NEMA Method 1 - Colored insulation with
contrasting ink tracers as required. Six different
insulation colors and four different colored ink
tracers are used to provide positive identification
through 21 conductors. The same identification
sequence may be repeated for cables containing
more than 21 conductors.
ICEA/NEMA Method 4 - A neutral- or single-colored
insulation compound is surface ink printed with
conductor number to provide positive conductor
identification through 21 conductors. The identification sequence is repeated for cables containing more
than 21 conductors.
Color Code Charts
ICEA METHOD 1, Table K-2
Conductor
No.
Base
Color
Spiral
Stripe
Conductor
No.
1
Black
---
19
Orange
Blue
2
Red
---
20
Yellow
Blue
3
Blue
---
21
Brown
Blue
4
Orange
---
22
Black
Orange
5
Yellow
---
23
Red
Orange
6
Brown
---
24
Blue
Orange
7
Red
Black
25
Yellow
Orange
8
Blue
Black
26
Brown
Orange
9
Orange
Black
27
Black
Yellow
10
Yellow
Black
28
Red
Yellow
11
Brown
Black
29
Blue
Yellow
12
Black
Red
30
Orange
Yellow
Blue
Red
31
Brown
Yellow
14
Orange
Red
32
Black
Brown
15
Yellow
Red
33
Red
Brown
16
Brown
Red
34
Blue
Brown
17
Black
Blue
35
Orange
Brown
18
Red
Blue
36
Yellow
Brown
13
Base
Color
Spiral
Stripe
NOTE: Color code repeats after 36 conductors. No green or white conductors/stripes.
For different colors, please call 800.633.6339 for information.
168
Tray Cables