fast acting i class j fuses a4j

advertisement
~Ferraz: ­
AMP-TRAP®
.iif Shavvn'lut
FAST ACTING I CLASS J FUSES
A4J
Standard Fuse Ampere Ratings, Catalog Numbers
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
1
A4J1
45
A4J45
175
A4J175
3
A4J3
50
A4J50
200
A4J200
6
A4J6
60
A4J60
225
A4J225
10
A4J10
70
A4J70
250
A4J250
15
A4J15
80
A4J80
300
A4J300
20
A4J20
90
A4J90
350
A4J350
25
A4J25
100
A4J1 00
400
A4J400
30
A4J30
110
A4J110
450
A4J450
35
A4J35
125
A4J125
500
A4J500
40
A4J40
150
A4J150
600
A4J600
Recommended Fuse Blocks
With Box Connectors for
Amp-trap Class J Fuses
Fuse
Ampere
Rating
1·60A
0-30
31-60
61-100
101-200
201-400
401-600
Catalog Number
600V OR LESS
3 pole
1 Pole
US3J11
US6J11
61 036J
62001J
64031J
6631J
US3J31
US6J31
61 038J
62003J
64033J
6633J
A variety of pole configurations and termination provisions is available. Refer to the fuse
block section of this catalog for details.
Dimensions
AMPERE
RATING
1-30
31-60
61-100
101-200
201-400
401-600
c
B
A
ln.
2-1 /4
2-3/8
4-5/8
5-3/4
7-1 /8
8
mm
57
60
117
146
181
203
ln.
13/16
1-1/16
1-1 /8
1-5/8
2-1 /8
2-1!2
mm
21
27
29
41
54
64
ln.
1/8
3/16
1/4
3/8
D
mm
-
3.2
4.8
6.3
9.5
F
E
ln.
-
mm
ln.
mm
ln.
-
-
-
-
-
-
3/4
1-1/8
1-5/8
2
19
29
41
51
1
1-3/8
1-7/8
2-1 /8
8 10
H
G
mm
ln.
mm
ln.
mm
-
-
-
-
-
-
-
-
-
25
35
48
54
3-5/8
4-3/8
5-1 /4
6
3/8
3/8
17/32
11/16
10
10
13
18
9/32
9/32
13/32
17/32
7
7
10
13
92
111
133
152
-
ifFerraz
ShaWJnut
FAST ACTING I CLASS J
AMP-TRAP®
A4J
FOR EXCELLENT CURRENT LIMITING
PROTECTION
A4J Class J fuses deliver excellent current-limiting
protection to a wide variety of applications. Their
unique dimensions prevent the substitution of
other fuses with lower voltage ratings, interrupting
ratings , or current-limiting capability.
Features I Benefits
,... High current limitation for low peak let-thru current
,... Unique dimensions prevent replacement by other fuse
classes
,... Fiberglass body provides dimensional stability in
harsh industrial environments
,... Easy-to-read imprint label for quick recognition
and replacement
HIGHLIGHTS:
APPLICATIONS:
,... Fast Acting
,... Very CurrentLimiting
,...
,...
,...
,...
,...
,...
,...
,...
,... DC Ratings
Ratings
Capacitors
Loadcenters
Pane/boards
Switchboards
Bus Duct
Feeder Circuits
Circuit Breakers
Lighting, Heating, and
General Loads
89
Approvals
... AC : 1 to 600A
600VAC , 200kA I.R.
,... UL Listed to Standard
248-8.
... DC: 1 to 600A
,... CSA Certified to
Standard C22.2
No. 248.8
300VOC, 20kA I.R.
... DC Tested to UL
198L limits
... IEC 269-2-1
B
SMARTSPOT INDICATOR AMP-TRAP 2000®
Ferraz -
5
Shavvn~ut
AJT
TIME DELAY I CLASS J FUSES
Standard Fuse Ampere Ratln s, Catalog Numbers
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
1
AJT1
AJT1-1/4
AJT1-1 /2
AJT1-6/1 0
AJT1-8/1 0
AJT2
AJT2-1 /4
AJT2-1/2
AJT2-8/10
AJT3
AJT3-2/10
AJT3-1/2
AJT4
4-1 /2
AJT4-1 /2
AJT5
AJT5-6/10
AJT6
AJT6-1/4
AJT7
AJT8
AJT9
AJT10
AJT12
AJT15
AJT17 -1/2
AJT20
25
30
35
40
45
50
60
70
80
90
100
110
AJT25
AJT30
AJT35
AJT40
AJT45
AJT50
AJT60
AJT70
AJT80
AJT90
AJT100
AJT110
125
150
175
200
225
250
300
350
400
450
500
600
AJT125
AJT150
AJT175
AJT200
AJT225
AJT250
AJT300
AJT350
AJT400
AJT450
AJT500
AJT600
1-1/4
1-1/2
1-6/10
1-8/10
2
2-1/4
2-1/2
2-8/10
3
3-2/10
3-1/2
4
5
5-6/10
6
6-1/4
7
8
9
10
12
15
17-1 /2
20
Recommen ed Fuse Blocks
With Box Co ctors for
Amp-trap® Class J FUses
Fuse
Catalog Number
Ampere
600V OR LESS
Rating
3 pole
1 Pole
0-30
31-60
61-100
101-200
201-400
401-600
US3J11
US6J11
61 036J
62001J
64031J
6631J
US3J31
US6J31
61 038J
62003J
64033J
6633J
A variety of pole configurations and termination
provisions is available.
Note Indicator Not availible (1-7a)
II
g
I .J
1-60A
Dim nslons
AMPERE
RATING
1-30
31-60
61-100
101-200
201-400
401-600
c
B
A
mm
ln.
mm
ln.
mm
ln.
mm
2-1/4
2-3/8
4-5/8
5-3/4
7-1 /8
8
57
60
117
146
181
203
13/16
1-1 /16
1-1/16
1-5/8
2-1/8
2-1/2
21
27
27
41
54
64
-
-
-
-
-
-
-
-
-
-
1/8
3/16
1/4
3.2
4.8
6.3
9.5
3/4
1-1/8
1-5/8
2
19
29
41
51
r
A -----tl_,
1.2~
~----------~--+---~~
AOS-S
t
3!8
1
1-3/8
1-7/8
2-1 /8
G
H
mm
ln.
mm
ln.
mm
-
-
-
-
-
-
ln.
-
-
-
-
-
-
25
35
48
54
3-5/8
4-3/8
5-1 /4
6
92
111
133
152
3/8
3/8
17/32
11 /16
10
10
14
18
9/32
9/32
13/32
17/32
7
7
10
13
unl fEll dimensions:
(31 . 4)
'3)
F
ln.
~--
(~0
E
mm
0 tionalla IcatortMJcroswltch
1.61
D
ln.
I
Note Fuses with the El option will receive
the AOS-S or AOS-0 Add-On-Switch
I It-
.70~
( 17 B)
~
A3
CATALOG NUMBER
A
AJT(70-1 00)-EI
2.80
(71.0)
AJT(11 0-200)-EI
3.22
(81.8)
AJT(225 -400)-EI
3.24
(82.2)
AJT(450-600)-EI
3.61
(91 .8)
_ Ferraz. Shavvrnut
SMARTSPOT INDICATOR AMP-TRAP 2000®
AJT
TIME DELAY I CLASS J
SMARTSPOT™ WITH MAXIMUM CIRCUIT
PROTECTION
Amp-trap 2000®SmartSpot™ AJT fuses now
provide a visual open fuse indicator. With advanced
material technology added to the existing product
line the AJT fuse provides IEC Type "2" (No Damage)
protection to main, feeder, and branch circuits, for all
types of loads - yet, they require only half the
mounting space needed for 600VAC Class RK fuses.
AJT's time delay characteristics for handling harmless in-rush currents, its current limiting ability (the
most current limiting UL fuse class!), and wide range
of ratings (from 1 to 600 Amperes)- give exceHent
protection for all your applications.
Features/Benefits
~
Solid State SmartSpot Indicator
Time delay for motor starting and transformer inrush
~ 300kA interrupting rating -self-certified,
UL witnessed tests
~ Extremely current limiting for low peak leHhru current
~ Most current limiting UL class fuse
~ Small footprint requires less mounting space and
all ows smaller, more economical fuse blocks
~ Easy 2-to-1 selectivity for prevention of nuisance
shutdowns
~ Unique Class J dimensions prevent rep lacement errors
~ High-visibility orange label gives instant recognition
~ Metal-embossed date and catalog number for
traceability and lasting identification
~ Fiberglass body provides dimensional stability in harsh
industrial settings
~ High-grade silica filler ensures fast arc quenching
~ Optional El Indicator/Switch mount for AJT70 to
600 open fuse indication
~
HIGHLIGHTS:
APPLICATIONS:
~
~
~
~
~
~
Smart Spot Indicator
Time Delay
Highly Current Limiting
DC Ratings
Optional Mechanical
Indicator
(70 to 600A fuses)
~
~
~
~
~
~
~
~
~
Motor Circuits
Mains
Feeders
Branch Circuits
Lighting, Heating
& General Loads
Transformers
Control Panels
Circuit Breaker Back-up
Bus Duct
Load Centers
Ratings
~
AC: 1 to 600A
600VAC, 200kA I.R.
(self certified for
600VAC, 300kA I.R ,
UL witnessed)
DC: 1 to 600A
500VDC , 100kA I.R.
Approvals
AJT (1-600):
~ UL Listed to
Standard 248-8
~ DC Listed to UL
Standard 198L
~ CSA Certified to
Standard C22.2
No. 248.8
~ IEC 269-2-1
AJT (70-600) El:
~ UL Component
Recognized
~ DC Tested to UL
Standard 198L
A2
Download