~Ferraz: ­ AMP-TRAP® .iif Shavvn'lut FAST ACTING I CLASS J FUSES A4J Standard Fuse Ampere Ratings, Catalog Numbers AMPERE RATING CATALOG NUMBER AMPERE RATING CATALOG NUMBER AMPERE RATING CATALOG NUMBER 1 A4J1 45 A4J45 175 A4J175 3 A4J3 50 A4J50 200 A4J200 6 A4J6 60 A4J60 225 A4J225 10 A4J10 70 A4J70 250 A4J250 15 A4J15 80 A4J80 300 A4J300 20 A4J20 90 A4J90 350 A4J350 25 A4J25 100 A4J1 00 400 A4J400 30 A4J30 110 A4J110 450 A4J450 35 A4J35 125 A4J125 500 A4J500 40 A4J40 150 A4J150 600 A4J600 Recommended Fuse Blocks With Box Connectors for Amp-trap Class J Fuses Fuse Ampere Rating 1·60A 0-30 31-60 61-100 101-200 201-400 401-600 Catalog Number 600V OR LESS 3 pole 1 Pole US3J11 US6J11 61 036J 62001J 64031J 6631J US3J31 US6J31 61 038J 62003J 64033J 6633J A variety of pole configurations and termination provisions is available. Refer to the fuse block section of this catalog for details. Dimensions AMPERE RATING 1-30 31-60 61-100 101-200 201-400 401-600 c B A ln. 2-1 /4 2-3/8 4-5/8 5-3/4 7-1 /8 8 mm 57 60 117 146 181 203 ln. 13/16 1-1/16 1-1 /8 1-5/8 2-1 /8 2-1!2 mm 21 27 29 41 54 64 ln. 1/8 3/16 1/4 3/8 D mm - 3.2 4.8 6.3 9.5 F E ln. - mm ln. mm ln. - - - - - - 3/4 1-1/8 1-5/8 2 19 29 41 51 1 1-3/8 1-7/8 2-1 /8 8 10 H G mm ln. mm ln. mm - - - - - - - - - 25 35 48 54 3-5/8 4-3/8 5-1 /4 6 3/8 3/8 17/32 11/16 10 10 13 18 9/32 9/32 13/32 17/32 7 7 10 13 92 111 133 152 - ifFerraz ShaWJnut FAST ACTING I CLASS J AMP-TRAP® A4J FOR EXCELLENT CURRENT LIMITING PROTECTION A4J Class J fuses deliver excellent current-limiting protection to a wide variety of applications. Their unique dimensions prevent the substitution of other fuses with lower voltage ratings, interrupting ratings , or current-limiting capability. Features I Benefits ,... High current limitation for low peak let-thru current ,... Unique dimensions prevent replacement by other fuse classes ,... Fiberglass body provides dimensional stability in harsh industrial environments ,... Easy-to-read imprint label for quick recognition and replacement HIGHLIGHTS: APPLICATIONS: ,... Fast Acting ,... Very CurrentLimiting ,... ,... ,... ,... ,... ,... ,... ,... ,... DC Ratings Ratings Capacitors Loadcenters Pane/boards Switchboards Bus Duct Feeder Circuits Circuit Breakers Lighting, Heating, and General Loads 89 Approvals ... AC : 1 to 600A 600VAC , 200kA I.R. ,... UL Listed to Standard 248-8. ... DC: 1 to 600A ,... CSA Certified to Standard C22.2 No. 248.8 300VOC, 20kA I.R. ... DC Tested to UL 198L limits ... IEC 269-2-1 B SMARTSPOT INDICATOR AMP-TRAP 2000® Ferraz - 5 Shavvn~ut AJT TIME DELAY I CLASS J FUSES Standard Fuse Ampere Ratln s, Catalog Numbers AMPERE RATING CATALOG NUMBER AMPERE RATING CATALOG NUMBER AMPERE RATING CATALOG NUMBER AMPERE RATING CATALOG NUMBER 1 AJT1 AJT1-1/4 AJT1-1 /2 AJT1-6/1 0 AJT1-8/1 0 AJT2 AJT2-1 /4 AJT2-1/2 AJT2-8/10 AJT3 AJT3-2/10 AJT3-1/2 AJT4 4-1 /2 AJT4-1 /2 AJT5 AJT5-6/10 AJT6 AJT6-1/4 AJT7 AJT8 AJT9 AJT10 AJT12 AJT15 AJT17 -1/2 AJT20 25 30 35 40 45 50 60 70 80 90 100 110 AJT25 AJT30 AJT35 AJT40 AJT45 AJT50 AJT60 AJT70 AJT80 AJT90 AJT100 AJT110 125 150 175 200 225 250 300 350 400 450 500 600 AJT125 AJT150 AJT175 AJT200 AJT225 AJT250 AJT300 AJT350 AJT400 AJT450 AJT500 AJT600 1-1/4 1-1/2 1-6/10 1-8/10 2 2-1/4 2-1/2 2-8/10 3 3-2/10 3-1/2 4 5 5-6/10 6 6-1/4 7 8 9 10 12 15 17-1 /2 20 Recommen ed Fuse Blocks With Box Co ctors for Amp-trap® Class J FUses Fuse Catalog Number Ampere 600V OR LESS Rating 3 pole 1 Pole 0-30 31-60 61-100 101-200 201-400 401-600 US3J11 US6J11 61 036J 62001J 64031J 6631J US3J31 US6J31 61 038J 62003J 64033J 6633J A variety of pole configurations and termination provisions is available. Note Indicator Not availible (1-7a) II g I .J 1-60A Dim nslons AMPERE RATING 1-30 31-60 61-100 101-200 201-400 401-600 c B A mm ln. mm ln. mm ln. mm 2-1/4 2-3/8 4-5/8 5-3/4 7-1 /8 8 57 60 117 146 181 203 13/16 1-1 /16 1-1/16 1-5/8 2-1/8 2-1/2 21 27 27 41 54 64 - - - - - - - - - - 1/8 3/16 1/4 3.2 4.8 6.3 9.5 3/4 1-1/8 1-5/8 2 19 29 41 51 r A -----tl_, 1.2~ ~----------~--+---~~ AOS-S t 3!8 1 1-3/8 1-7/8 2-1 /8 G H mm ln. mm ln. mm - - - - - - ln. - - - - - - 25 35 48 54 3-5/8 4-3/8 5-1 /4 6 92 111 133 152 3/8 3/8 17/32 11 /16 10 10 14 18 9/32 9/32 13/32 17/32 7 7 10 13 unl fEll dimensions: (31 . 4) '3) F ln. ~-- (~0 E mm 0 tionalla IcatortMJcroswltch 1.61 D ln. I Note Fuses with the El option will receive the AOS-S or AOS-0 Add-On-Switch I It- .70~ ( 17 B) ~ A3 CATALOG NUMBER A AJT(70-1 00)-EI 2.80 (71.0) AJT(11 0-200)-EI 3.22 (81.8) AJT(225 -400)-EI 3.24 (82.2) AJT(450-600)-EI 3.61 (91 .8) _ Ferraz. Shavvrnut SMARTSPOT INDICATOR AMP-TRAP 2000® AJT TIME DELAY I CLASS J SMARTSPOT™ WITH MAXIMUM CIRCUIT PROTECTION Amp-trap 2000®SmartSpot™ AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the AJT fuse provides IEC Type "2" (No Damage) protection to main, feeder, and branch circuits, for all types of loads - yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT's time delay characteristics for handling harmless in-rush currents, its current limiting ability (the most current limiting UL fuse class!), and wide range of ratings (from 1 to 600 Amperes)- give exceHent protection for all your applications. Features/Benefits ~ Solid State SmartSpot Indicator Time delay for motor starting and transformer inrush ~ 300kA interrupting rating -self-certified, UL witnessed tests ~ Extremely current limiting for low peak leHhru current ~ Most current limiting UL class fuse ~ Small footprint requires less mounting space and all ows smaller, more economical fuse blocks ~ Easy 2-to-1 selectivity for prevention of nuisance shutdowns ~ Unique Class J dimensions prevent rep lacement errors ~ High-visibility orange label gives instant recognition ~ Metal-embossed date and catalog number for traceability and lasting identification ~ Fiberglass body provides dimensional stability in harsh industrial settings ~ High-grade silica filler ensures fast arc quenching ~ Optional El Indicator/Switch mount for AJT70 to 600 open fuse indication ~ HIGHLIGHTS: APPLICATIONS: ~ ~ ~ ~ ~ ~ Smart Spot Indicator Time Delay Highly Current Limiting DC Ratings Optional Mechanical Indicator (70 to 600A fuses) ~ ~ ~ ~ ~ ~ ~ ~ ~ Motor Circuits Mains Feeders Branch Circuits Lighting, Heating & General Loads Transformers Control Panels Circuit Breaker Back-up Bus Duct Load Centers Ratings ~ AC: 1 to 600A 600VAC, 200kA I.R. (self certified for 600VAC, 300kA I.R , UL witnessed) DC: 1 to 600A 500VDC , 100kA I.R. Approvals AJT (1-600): ~ UL Listed to Standard 248-8 ~ DC Listed to UL Standard 198L ~ CSA Certified to Standard C22.2 No. 248.8 ~ IEC 269-2-1 AJT (70-600) El: ~ UL Component Recognized ~ DC Tested to UL Standard 198L A2