AMP-TRAP- Shawmut A4J FAST ACTING / CLASS J FUSES Standard Fuse Ampere Ratings, Catal: AMPERE RATING CATALOG NUMBER AMPERE RATING CATALOG NUMBER AMPERE RATING CATALOG NUMBER 1 A4J1 45 A4J45 175 A4J175 3 A4J3 50 A4J50 200 A4J200 6 A4J6 60 A4J60 225 A4J225 10 A4J10 70 A4J70 250 A4J250 15 A4J15 80 A4J80 300 A4J300 20 A4J20 90 A4J90 350 A4J350 25 A4J25 100 A4J100 400 A4J400 30 A4J30 110 A4J110 450 A4J450 35 A4J35 125 A4J125 500 A4J500 A4J40 150 A4J150 600 A4J600 40 Recommended Fuse Blocks With Box Connectors for Amp-' ~* "" 'S Fuse 1-60A h-E- -la|- si 0-30 \ -4p- I 31-60 61-100 101-200 201-400 401-600 F 70-600A AMPERE RATING 1-30 31-60 61-100 101-200 201-400 401-600 mm In. mm 2-1/4 57 13/16 21 1-1/16 1-1/8 1-5/8 2-1/8 2-1/2 27 2-3/8 60 4-5/8 117 5-3/4 146 7-1/8 181 8 203 600V OR LESS IPole 3 pole US3J1I US6J1I 61036J 62001J 64031 J 6631J US3J3I US6J3I 61038J 62003J 64033J 6633J A variety of pole configurations and termination provisions is available Refer to the fuse block section of this catalog for details. C B A In. Catalog Number Ampere Rating D In. - mm - 29 1/8 41 3/16 54 64 F E mm - In. - mm - 3-5/8 92 3/8 10 9/32 7 4-3/8 111 3/8 10 9/32 7 48 5-1/4 133 17/32 13 13/32 10 54 6 152 11/16 18 17/32 13 In. - 19 25 29 1-3/8 35 1-5/8 41 1-7/8 2 51 2-1/8 32 3/4 48 1-1/8 1/4 6.3 3/8 95 B 10 H In. - mm - mm - G mm - In. 1 In. - AMP-TRAP® A4J FAST ACTING / CLA: FOR EXCELLENT CURRENT LIMITING PROTECTION A4J Class J fuses deliver excellent current-limiting protection to a wide variety of applications. Their unique dimensions prevent the substitution of other fuses with lower voltage ratings, interrupting ratings, or current-limiting capability. Features/Benefits - High current limitation for low peak let-thru current Unique dimensions prevent replacement by other fuse classes '• Fiberglass body provides dimensional stability in harsh industrial environments > Easy-to-read imprint label for quick recognition and replacement HIGHLIGHTS: APPLICATIONS: > Fast Acting >- Very CurrentLimiting > > > > > >• > > > DC Ratings Ratings Capacitors Loadcenters Panelboards Switchboards Bus Duct Feeder Circuits Circuit Breakers Lighting, Heating, and General Loads @ B9 Approvals AC 1 to 600A 600VAC,200kAIR > UL Listed to Standard 248-8 DC: 1 to 600A 300VDC, 20kA I R > CSA Certified to Standard C22 2 No 2488 > DC Tested to UL 198L limits > IEC 269-2-1 SMARTSPOT INDICATOR AMP-TRAP 2000 TIME DELAY/CLASS J FUSES AJT Standard Fuse Ampere Ratings, Catalog Numbers AMPERE RATING CATALOG NUMBER AMPERE RATING CATALOG NUMBER AJT4-1/2 AJT5 AJT5-6/10 AJT6 AJT6-1/4 AJT7 AJT8 AJT9 AJT10 AJT12 AJT15 AJT1 7-1/2 AJT20 1 AJT1 4-1/2 1 1/4 AJT1 1/4 5 1-1/2 AJT1-1/2 AJT1 6/10 AJT1-8/10 AJT2 AJT2 1/4 AJT2-1/2 AJT2-8/10 AJT3 AJT3 2/1 0 AJT3-1/2 AJT4 1 6/10 1-8/10 2 2-1/4 2-1/2 2-8/10 3 3-2/10 3-1/2 4 5-6/10 6 6 1/4 7 8 9 10 12 15 17-1/2 20 AMPERE RATING CATALOG NUMBER 25 AJT25 AJT30 AJT35 AJT40 AJT45 AJT50 AJT60 AJT70 AJT80 AJT90 AJT100 AJT110 30 35 40 45 50 60 70 80 90 100 110 AMPERE RATING CATALOG NUMBER 125 AJT125 AJT150 AJT1 75 AJT200 AJT225 AJT250 AJT300 AJT350 AJT400 AJT450 AJT500 AJT600 150 175 200 225 250 300 350 400 450 500 600 Recommended Fuse Blocks With Box Connectors for Amp-trap® Class J Fuses Fuse Catalog Number Ampere 600V OR LESS Rating IPole 3 pole 0-30 31-60 61-100 101-200 201-400 401-600 US3J1I US6J1I 61036J 62001 J 64031J 6631J US3J3I US6J3I 61038J 62003J 64033J 6633J A variety of pole configurations and termination provisions is available Note Indicator Not availible (1-7a) 1-60A 70-600A B A AMPERE RATING 1-30 31-60 61-100 101-200 201-400 401-600 C E D In. mm In. mm 2 1/4 57 13/16 21 23/8 60 - - 117 27 1/8 53/4 146 41 7-1/8 181 8 203 1-1/16 1 1/16 1 5/8 2-1/8 2 1/2 27 4-5/8 In. - mm - 32 3/4 3/16 48 1-1/8 54 1/4 63 64 3/8 95 In. mm - In. - 19 1 25 29 1-3/8 35 1-5/8 41 1 7/8 2 51 2-1/8 48 54 H G F in. - mm mm - In. - mm - In. - mm - 3 5/8 92 3/8 10 9/32 7 4-3/8 5 1/4 111 3/8 10 9/32 7 133 17/32 14 13/32 10 6 152 11/16 18 17/32 13 Optional Intflcator/Microswfteii Mount (ED dimensions; /^ — ,t 1 1 t •^— Note Fuses with the El option will receive N th AOS-S or AOS-Q Add On-Switch the CATALOG NUMBER A AJT(70 100)-EI 280 (710) AJT(1 10-200) El 322 (818) AJT(225 400} El 324 (822) AJT(450-600)-EI 361 (918) r AOS-S 1 67 El (170) f (31 2 J) —tf 1 1 J_ o. f^ M-' A3 SMARTSPOT INDICATOR AMP-TRAP 2000' i Shawmut AJT TIME DELAY / CLASS J SMARTSPOT™ WITH MAXIMUM CIRCUIT PROTECTION Amp-trap 2000® SmartSpot™ AJT fuses now provide a visual open fuse indicator. With advanced material technology added to the existing product line the AJT fuse provides IEC Type "2" (No Damage) protection to main, feeder, and branch circuits, for all types of loads — yet, they require only half the mounting space needed for 600VAC Class RK fuses. AJT's time delay characteristics for handling harmless in-rush currents, its current limiting ability (the most current limiting UL fuse class!), and wide range of ratings (from 1 to 600 Amperes) — give excellent protection for all your applications. Features/Benefits HIGHLIGHTS: x x x x x Smart Spot Indicator Time Delay Highly Current Limiting DC Ratings Optional Mechanical Indicator (70 to 600A fuses) APPLICATIONS: > Motor Circuits x Mains > Feeders '*• Branch Circuits > Lighting, Heating & General Loads x Transformers x Control Panels x Circuit Breaker Back-up X Bus Duct x Load Centers x Solid State SmartSpot Indicator X Time delay for motor starting and transformer inrush X SOOkA interrupting rating self-certified, UL witnessed tests X Extremely current limiting for low peak let-thru current X Most current limiting UL class fuse X Small footprint requires less mounting space and allows smaller, more economical fuse blocks > Easy 2-to-1 selectivity for prevention of nuisance shutdowns X Unique Class J dimensions prevent replacement errors X High-visibility orange label gives instant recognition X Metal-embossed date and catalog number for traceability and lasting identification > Fiberglass body provides dimensional stability in harsh industrial settings X High-grade silica filler ensures fast arc quenching X Optional El Indicator/Switch mount for AJT70 to 600 open fuse indication Ratings X AC: 1 to 600A 600VAC, 200kA I R (self certified for 600VAC, SOOkA I.R, UL witnessed) DC: 1 to 600A 500VDC, 100kAI.R. Approvals AJT (1-600): y UL Listed to Standard 248-8 > DC Listed to UL Standard 198L > CSA Certified to Standard C22.2 No. 2488 X IEC 269-2-1 AJT (70-600) El: > UL Component Recognized > DC Tested to UL Standard 198L ©<§*! A2