FAST ACTING / CLASS J FUSES

advertisement
AMP-TRAP-
Shawmut
A4J
FAST ACTING / CLASS J FUSES
Standard Fuse Ampere Ratings, Catal:
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
1
A4J1
45
A4J45
175
A4J175
3
A4J3
50
A4J50
200
A4J200
6
A4J6
60
A4J60
225
A4J225
10
A4J10
70
A4J70
250
A4J250
15
A4J15
80
A4J80
300
A4J300
20
A4J20
90
A4J90
350
A4J350
25
A4J25
100
A4J100
400
A4J400
30
A4J30
110
A4J110
450
A4J450
35
A4J35
125
A4J125
500
A4J500
A4J40
150
A4J150
600
A4J600
40
Recommended Fuse Blocks
With Box Connectors for
Amp-' ~* "" 'S
Fuse
1-60A
h-E-
-la|-
si
0-30
\
-4p-
I
31-60
61-100
101-200
201-400
401-600
F
70-600A
AMPERE
RATING
1-30
31-60
61-100
101-200
201-400
401-600
mm
In.
mm
2-1/4
57
13/16
21
1-1/16
1-1/8
1-5/8
2-1/8
2-1/2
27
2-3/8
60
4-5/8
117
5-3/4
146
7-1/8
181
8
203
600V OR LESS
IPole
3 pole
US3J1I
US6J1I
61036J
62001J
64031 J
6631J
US3J3I
US6J3I
61038J
62003J
64033J
6633J
A variety of pole configurations and termination provisions is available Refer to the fuse
block section of this catalog for details.
C
B
A
In.
Catalog Number
Ampere
Rating
D
In.
-
mm
-
29
1/8
41
3/16
54
64
F
E
mm
-
In.
-
mm
-
3-5/8
92
3/8
10
9/32
7
4-3/8
111
3/8
10
9/32
7
48
5-1/4
133
17/32
13
13/32
10
54
6
152
11/16
18
17/32
13
In.
-
19
25
29
1-3/8
35
1-5/8
41
1-7/8
2
51
2-1/8
32
3/4
48
1-1/8
1/4
6.3
3/8
95
B 10
H
In.
-
mm
-
mm
-
G
mm
-
In.
1
In.
-
AMP-TRAP®
A4J
FAST ACTING / CLA:
FOR EXCELLENT CURRENT LIMITING
PROTECTION
A4J Class J fuses deliver excellent current-limiting
protection to a wide variety of applications. Their
unique dimensions prevent the substitution of
other fuses with lower voltage ratings, interrupting
ratings, or current-limiting capability.
Features/Benefits
-
High current limitation for low peak let-thru current
Unique dimensions prevent replacement by other fuse
classes
'• Fiberglass body provides dimensional stability in
harsh industrial environments
> Easy-to-read imprint label for quick recognition
and replacement
HIGHLIGHTS:
APPLICATIONS:
> Fast Acting
>- Very CurrentLimiting
>
>
>
>
>
>•
>
>
> DC Ratings
Ratings
Capacitors
Loadcenters
Panelboards
Switchboards
Bus Duct
Feeder Circuits
Circuit Breakers
Lighting, Heating, and
General Loads
@
B9
Approvals
AC 1 to 600A
600VAC,200kAIR
> UL Listed to Standard
248-8
DC: 1 to 600A
300VDC, 20kA I R
> CSA Certified to
Standard C22 2
No 2488
>
DC Tested to UL
198L limits
> IEC 269-2-1
SMARTSPOT INDICATOR AMP-TRAP 2000
TIME DELAY/CLASS J FUSES
AJT
Standard Fuse Ampere Ratings, Catalog Numbers
AMPERE
RATING
CATALOG
NUMBER
AMPERE
RATING
CATALOG
NUMBER
AJT4-1/2
AJT5
AJT5-6/10
AJT6
AJT6-1/4
AJT7
AJT8
AJT9
AJT10
AJT12
AJT15
AJT1 7-1/2
AJT20
1
AJT1
4-1/2
1 1/4
AJT1 1/4
5
1-1/2
AJT1-1/2
AJT1 6/10
AJT1-8/10
AJT2
AJT2 1/4
AJT2-1/2
AJT2-8/10
AJT3
AJT3 2/1 0
AJT3-1/2
AJT4
1 6/10
1-8/10
2
2-1/4
2-1/2
2-8/10
3
3-2/10
3-1/2
4
5-6/10
6
6 1/4
7
8
9
10
12
15
17-1/2
20
AMPERE
RATING
CATALOG
NUMBER
25
AJT25
AJT30
AJT35
AJT40
AJT45
AJT50
AJT60
AJT70
AJT80
AJT90
AJT100
AJT110
30
35
40
45
50
60
70
80
90
100
110
AMPERE
RATING
CATALOG
NUMBER
125
AJT125
AJT150
AJT1 75
AJT200
AJT225
AJT250
AJT300
AJT350
AJT400
AJT450
AJT500
AJT600
150
175
200
225
250
300
350
400
450
500
600
Recommended Fuse Blocks
With Box Connectors for
Amp-trap® Class J Fuses
Fuse Catalog Number
Ampere
600V OR LESS
Rating
IPole
3 pole
0-30
31-60
61-100
101-200
201-400
401-600
US3J1I
US6J1I
61036J
62001 J
64031J
6631J
US3J3I
US6J3I
61038J
62003J
64033J
6633J
A variety of pole configurations and termination
provisions is available
Note Indicator Not availible (1-7a)
1-60A
70-600A
B
A
AMPERE
RATING
1-30
31-60
61-100
101-200
201-400
401-600
C
E
D
In.
mm
In.
mm
2 1/4
57
13/16
21
23/8
60
-
-
117
27
1/8
53/4
146
41
7-1/8
181
8
203
1-1/16
1 1/16
1 5/8
2-1/8
2 1/2
27
4-5/8
In.
-
mm
-
32
3/4
3/16
48
1-1/8
54
1/4
63
64
3/8
95
In.
mm
-
In.
-
19
1
25
29
1-3/8
35
1-5/8
41
1 7/8
2
51
2-1/8
48
54
H
G
F
in.
-
mm
mm
-
In.
-
mm
-
In.
-
mm
-
3 5/8
92
3/8
10
9/32
7
4-3/8
5 1/4
111
3/8
10
9/32
7
133
17/32
14
13/32
10
6
152
11/16
18
17/32
13
Optional Intflcator/Microswfteii Mount (ED dimensions;
/^
—
,t 1
1
t
•^—
Note Fuses with the El option will receive
N
th AOS-S or AOS-Q Add On-Switch
the
CATALOG NUMBER
A
AJT(70 100)-EI
280
(710)
AJT(1 10-200) El
322
(818)
AJT(225 400} El
324
(822)
AJT(450-600)-EI
361
(918)
r AOS-S 1
67
El
(170)
f
(31 2 J)
—tf
1
1
J_ o.
f^
M-'
A3
SMARTSPOT INDICATOR AMP-TRAP 2000'
i Shawmut
AJT
TIME DELAY / CLASS J
SMARTSPOT™ WITH MAXIMUM CIRCUIT
PROTECTION
Amp-trap 2000® SmartSpot™ AJT fuses now
provide a visual open fuse indicator. With advanced
material technology added to the existing product
line the AJT fuse provides IEC Type "2" (No Damage)
protection to main, feeder, and branch circuits, for all
types of loads — yet, they require only half the
mounting space needed for 600VAC Class RK fuses.
AJT's time delay characteristics for handling harmless in-rush currents, its current limiting ability (the
most current limiting UL fuse class!), and wide range
of ratings (from 1 to 600 Amperes) — give excellent
protection for all your applications.
Features/Benefits
HIGHLIGHTS:
x
x
x
x
x
Smart Spot Indicator
Time Delay
Highly Current Limiting
DC Ratings
Optional Mechanical
Indicator
(70 to 600A fuses)
APPLICATIONS:
> Motor Circuits
x Mains
> Feeders
'*• Branch Circuits
> Lighting, Heating
& General Loads
x Transformers
x Control Panels
x Circuit Breaker Back-up
X Bus Duct
x Load Centers
x Solid State SmartSpot Indicator
X Time delay for motor starting and transformer inrush
X SOOkA interrupting rating self-certified,
UL witnessed tests
X Extremely current limiting for low peak let-thru current
X Most current limiting UL class fuse
X Small footprint requires less mounting space and
allows smaller, more economical fuse blocks
> Easy 2-to-1 selectivity for prevention of nuisance
shutdowns
X Unique Class J dimensions prevent replacement errors
X High-visibility orange label gives instant recognition
X Metal-embossed date and catalog number for
traceability and lasting identification
> Fiberglass body provides dimensional stability in harsh
industrial settings
X High-grade silica filler ensures fast arc quenching
X Optional El Indicator/Switch mount for AJT70 to
600 open fuse indication
Ratings
X AC: 1 to 600A
600VAC, 200kA I R
(self certified for
600VAC, SOOkA I.R,
UL witnessed)
DC: 1 to 600A
500VDC, 100kAI.R.
Approvals
AJT (1-600):
y UL Listed to
Standard 248-8
> DC Listed to UL
Standard 198L
> CSA Certified to
Standard C22.2
No. 2488
X IEC 269-2-1
AJT (70-600) El:
> UL Component
Recognized
> DC Tested to UL
Standard 198L
©<§*!
A2
Download