LED 2D Retrofit High output LED retrofit 2D with extremely low power consumption. Slimline 31mm deep to fit most luminaires. Direct replacement for 2D compact fluorescents. • 25,000 hour long life LED lamp • 12,500 switching cycles • 4000K cool white • GR10q 4 pin cap • Not suitable for dimming • Separate NED/3/80 3 hour emergency module conversion kit available for installation into existing emergency fittings • For indoor use only Product Code Watts Volts (W) (V) Cap Colour Colour Appearance Temp (K) Initial Lumens (lm) CFL Dimensions Energy Order Equivalent (mm) Rating Qty (W) Dia H Single Carton LD7CW 7 240 GR10q 4 Pin Cool White 4000 740 16 135 135 1 LD13CW 13 240 GR10q 4 Pin Cool White 4000 1150 28 173 173 1 LD18CW 18 240 GR10q 4 Pin Cool White 4000 1850 38 200 200 NED380 3 Hour Emergency Conversion Kit 1 1 LED 2D Lamp Installation Guide: When working with mains voltage always consult a qualified electrician. The existing fitting must be switched off and isolated at the mains before commencing electrical work. Magnetic Ballast/Electronic Ballast (High Frequency): The electronic ballast is not required. Bypass the electronic ballast and plug the LED 2D lamp directly into the socket. The lamp socket will need to be rewired with the live to one side and the neutral to the other. The live and neutral must be wired to the appropriate socket holes and not be wired to the same side. L L N N L N W H GR10q 4 Pin Cap We have valued our reputation since 1878, why risk yours with anyone else? Crompton Lamps Limited registered in England and Wales No. 05590551 Registered office and correspondence address: Unit 2, Marrtree Business Park, Bowling Back Lane, Bradford BD4 8QE Tel: +44 (0)845 612 8151 Fax: +44 (0)845 612 8171 Email: sales@cromptonlamps.com Web: www.cromptonlamps.com All images and specifications are for illustration purposes only and are subject to change without notice. E. & O. E. © Crompton Lamps Limited 2015 LED 2D Retrofit Installation Manual Part Number: LD7CW / LD13CW / LD18CW/ 3033 It is recommended that the installation of this product be carried out by a qualified electrician. Isolate mains supply before commencing Magnetic Ballast Remove the starter and any power factor capacitor and plug the LED 2D REtrofit directly into the socket Electronic Ballast (High Frequency) The LED 2D Retrofit lamp does not require any ballast. Bypass the ballast by rewiring the luminaire following the diagrams below The lamp socket needs to be rewired with the LIVE to one side and the NEUTRAL to the other The LIVE and NEUTRAL must be wired to the appropriate socket holes and not wired to the same side Information given is for guidance only. All installations must comply with appropriate standards. Diagrams are for information only - please refer to a qualified electrician. If you have any uncertainty about the installation or usage of the LED lamp, please consult Crompton Lamps on the details below. We have valued our reputation since 1878, why risk yours with anyone else? Crompton Lamps Limited registered in England and Wales No. 05590551 Registered office and correspondence address: Unit 2, Marrtree Business Park, Bowling Back Lane, Bradford BD4 8QE Tel: +44 (0)845 612 8151 Fax: +44 (0)845 612 8171 Email: lamps@cromptonlamps.com Web: www.cromptonlamps.com