LED 2D Retrofit - Crompton Lamps Ltd

advertisement
LED 2D Retrofit
High output LED retrofit 2D with
extremely low power consumption.
Slimline 31mm deep to fit most
luminaires. Direct replacement for
2D compact fluorescents.
• 25,000 hour long life LED lamp
• 12,500 switching cycles
• 4000K cool white
• GR10q 4 pin cap
• Not suitable for dimming
• Separate NED/3/80 3 hour emergency
module conversion kit available
for installation into existing
emergency fittings
• For indoor use only
Product Code
Watts Volts
(W)
(V)
Cap
Colour
Colour
Appearance Temp
(K)
Initial
Lumens
(lm)
CFL
Dimensions Energy Order
Equivalent
(mm)
Rating Qty
(W)
Dia
H
Single Carton
LD7CW
7
240
GR10q 4 Pin
Cool White
4000
740
16
135
135
1
LD13CW
13
240
GR10q 4 Pin
Cool White
4000
1150
28
173
173
1
LD18CW
18
240
GR10q 4 Pin
Cool White
4000
1850
38
200
200
NED380
3 Hour Emergency Conversion Kit
1
1
LED 2D Lamp Installation Guide:
When working with mains voltage always consult a qualified electrician.
The existing fitting must be switched off and isolated at the mains before commencing
electrical work.
Magnetic Ballast/Electronic Ballast (High Frequency):
The electronic ballast is not required. Bypass the electronic ballast and plug the LED
2D lamp directly into the socket. The lamp socket will need to be rewired with the live
to one side and the neutral to the other. The live and neutral must be wired to the
appropriate socket holes and not be wired to the same side.
L
L
N N
L N
W
H
GR10q 4 Pin Cap
We have valued our reputation since 1878, why risk yours with anyone else?
Crompton Lamps Limited registered in England and Wales No. 05590551
Registered office and correspondence address: Unit 2, Marrtree Business Park, Bowling Back Lane, Bradford BD4 8QE
Tel: +44 (0)845 612 8151 Fax: +44 (0)845 612 8171 Email: sales@cromptonlamps.com Web: www.cromptonlamps.com
All images and specifications are for illustration purposes only and are subject to change without notice.
E. & O. E. © Crompton Lamps Limited 2015
LED 2D Retrofit
Installation Manual
Part Number: LD7CW / LD13CW / LD18CW/ 3033
It is recommended that the installation of this product be carried out by a qualified electrician.
Isolate mains supply before commencing
Magnetic Ballast
Remove the starter and any power factor capacitor and plug the LED 2D REtrofit directly
into the socket
Electronic Ballast (High Frequency)
The LED 2D Retrofit lamp does not require any ballast. Bypass the ballast by rewiring the
luminaire following the diagrams below
The lamp socket needs to be rewired with the LIVE to one side and the NEUTRAL to the
other
The LIVE and NEUTRAL must be wired to the appropriate socket holes and not wired to
the same side
Information given is for guidance only. All installations must comply with appropriate standards. Diagrams are for information only - please refer to a qualified
electrician. If you have any uncertainty about the installation or usage of the LED lamp, please consult Crompton Lamps on the details below.
We have valued our reputation since 1878, why risk yours with anyone else?
Crompton Lamps Limited registered in England and Wales No. 05590551
Registered office and correspondence address: Unit 2, Marrtree Business Park, Bowling Back Lane, Bradford BD4 8QE
Tel: +44 (0)845 612 8151 Fax: +44 (0)845 612 8171 Email: lamps@cromptonlamps.com Web: www.cromptonlamps.com