ENhanced TECnology www.entecene.co.kr Pad Mount Switchgear Pad Mount Switchgear General Features Pad mount switchgear is designed for distribution automation system with combination of circuit breaker, load break switch and direct circuit. Multiple selection of load break switches and circuit breakers make the end user`s distribution line system more flexible. SF6 gas insulated switchgear and Solid insulated switchgear will provide full support with various choice of controls in order to complete distribution line system. 2 ENhanced TECnology Ratings Item Unit Rated Maximum voltage Rated continuous current Closed loop and load breaking current Cable charging breaking current Transformer magnetizing breaking current Short circuit breaking capacity Symmetrical short time current, 1 sec Peak withstand current Short circuit making current Basic impulse withstand voltage(1.2 x 50 ) Power frequency withstand voltage, dry DC withstand voltage, 15min. Corona extinction voltage kV A A A A kArms kArms kApeak kApeak kV kV kV kV Load Break Switch 15 630 630 25 21/15 12.5 32.5 32.5 85/110 50 53 11 27 630 630 25 21/15 12.5 32.5 32.5 125 60 78 19 Circuit Breaker 15 630 630 25 21/15 12.5 12.5 32.5 32.5 110 50 53 11 27 630 630 25 21/15 12.5 12.5 32.5 32.5 125 60 78 19 Switchgear configureation Total Number of Circuit Total Number of Circuit Configuration 4 Configuration 6 ETPS1-4-2S1B1SW-A-NE Load Break Switch Circuit Break ETPG2-6-2S3B1W-A-E-E Direct Way Switch Without Earth * MULTIPLE COMBINATION OF CIRCUITS ARE AVAILABLE Ordering menu : 1~6 G : Gas type S : Solid type 1 : 15kV 2 : 27kV N : Total number of way(1~6) E: Earthed S : Load Break Switch M: Manual NE : Not Earthed B : Circuit Breaker E : Electrical W: direct way A : Auto(Built-In RTU option) SW: Switch without Earth Ex) ETPG1-6-2S4B-A-WE ETPS2-4-2S2B-A-E Pad Mount Switchgear 3 Pad Mount Switchgear Technical Features 1. Control Circuit Breaker/Load Break Switch controller, Protection Relay, FRTU, Modem can be placed Remote operation available (Built-In RTU : Option) 2. Load Break Switch(LBS) All circuit has independent operation function Each circuit has one operation hole to Close/Open/Earth Status Indicators of circuit breaker and load break switch are available Prevention of switching from Close to Earth by using 3 Position operations for LBS Operation Counter * 3-position operation Dual contacts : Enhanced Making and Disconnecting capacity Increased contact distance of Open status results the increment of Insulation capacity Due to Close-Open-Earth turn operation, mis-operation is prevented and provide Natural Locking structure Long life of contacts due to dual contact(divided arcing, less wear-out) * Solid Insulation type Load Break Switch Polymer insulation not by SF6 gas Environment Friendly 4 ENhanced TECnology 3. Circuit Breaker(CB) 5. Live-Line Indicator(Manual type switchgear) All circuit has independent operation function Close/Open operation by button in controller Earth operation is available on CB open status Indicators of circuit breaker status available Operation counter Live line indicator is provided on each circuit for safety 6. Voltage/Current sensing bushing 4. Gas Pressure gauge and valve (SF6 Gas type switchgear) Gas Pressure is indicated on Gauge Gas refilling valve available Current Transformer : 1000: 1 ratio (User`s choice) Accuracy : CVD type : 3 %(Standard), Resistor type P/T : 1%(option) Epoxy bushing : ANSI or DIN standard 7. Earth Terminal Convenient earthing 8. Battery 24V DC, 40AH Dead line operation available during 48hours Rechargeable by auxiliary power source (110/220Vac) 9. Manual Trip Device(Option) In case of No external power source and Battery Dead, Operation is available Consist of Lithium Ion Battery DC 15V 10. Over pressure rupture disc for Safety In case of tank pressure increasing, Over pressure rupture disk is necessary for safety Pad Mount Switchgear 5 Pad Mount Switchgear Controller Control Part Switch Control : EPGS1A Feeder Remote Terminal Unit Control Protection and Metering Dual Protection Relay : ETR-102 Built-In RTU : ETR-104 Protection Time Current Curve editable IEEE, IEC and 37 non-standard inverse time curves Protective settings in nonvolatile memory during power failure Delay time overcurrent protection(51P,51G) Instantaneous overcurrent protection(50P,50G) Negative sequence overcurrent protection(46) Cold load pickup and sequence coordination Underfrequency and load shedding(81) Undervoltage, overvoltage detection and alarm(27,59) Metering Voltage, Current Measures KW and KWH, Power factor Demand watts and VARs and frequency Load Profile data & Ocillogram Remote Communication 6 ENhanced TECnology RS232 Ports DNP3.0 porotocol based on IEC870-5, MODBUS Built-In RTU (Option) Setting, Metering and Data records accessible Construction SF6 Gas Type SWITCHGEAR Polymer(Solid) Type SWITCHGEAR LOAD BREAK SWITCH Pad Mount Switchgear 7 78-2 BUNCHEON-RI BONGDAM-EUP HWASEONG-CITY GYUNGGI-DO KOREA TEL: +82-31-227-1161 FAX : +82-31-227-1164 http://www.entecene.co.kr E-mail : entec@entecene.co.kr