Catalog Molded Case Circuit Breakers Molded Case Switches Ex9M3N Ex9M1S Ex9M2D Ex9M4D Ex9M Series www.NoarkUSA.com Electrical Equipment Supplier for the SmartGrid NOARK Electric provides reliable products and efficient solution to intelligent power and energy system. With a series of products and solutions, NOARK Electric is capable of serving traditional industries including utility, iron & steel manufacturing, building, petrochemicals, telecommunications, mechanical and other industries, also has become expert in some cutting-edge fields, such as solar energy, intelligent power distribution, wind energy, electric vehicle and energy storage. The over-expected performance of these products has been identified especially under an extremely harsh environment. In China, Europe, and the United States, NOARK Electric has four R&D centers, three distribution centers, 15 global sales branches and more than 1,000 employees. We hold the belief that a dedicated and professional work manner is the root to bring our customer with complete solution and satisfaction. NOARK Electric will continually be committed to reducing cost of operation and maintenance, bringing reliable technology and creating more customer value in long run. i SmartUnit A series of intelligent control units embedded in each electrical component, which enable them to communicate with every equipment in smart network. Besides, it has the abilities of self-judgement, storage and prompt react ion to integrate mutually with the entire system. This application can be effectively used in utility, industry, renewable energy and so on. InPower (Intelligent Power) Distribution System works on two main key components, SmartUnit and InServer (Intelligent Communication Server). The benefit of this integration to user is easy operation and management of power distribution system, through energy monitoring, remote operation, warning alarm, energy analysis, etc. Solarinel An electrical system solution to photovoltaic system. With a full range of PV products and optimized design of electrical system, it brings high efficiency and performance of the whole solar system. After being applied in over 1GW installation worldwide, Solarinel turns out to be a necessary component and ideal system to several of system application, from residential roof top in hot and humid tropical region to large solar farm in Tibet under extremely harsh environment. 2013 NOARK Electric • All Rights Reserved International Locations NOARK Electric Europe NOARK Electric North America NOARK Electric Europe NOARK Electric North America NOARK Electric Shanghai NOARK Electric Shanghai 2013 NOARK Electric • All Rights Reserved ii NOARK Electric invests heavily in R&D. Our Technology Center in Shanghai, China has over 100 professional engineers with expertise in such areas as product design, software development, system Cutting Edge Technology design, simulation analysis, reliability, manufacturing and more. NOARK Electric has an extensive portfolio of global patents and certifications that cover products, manufacturing facilities and NOARK Electric invests heavily in R&D. Our Technology Center in Shanghai, China has over 100 innovative technologies. professional engineers with expertise in such areas as product design, software development, system design, simulation analysis, reliability, manufacturing and more. NOARK Electric has an extensive portfolio of global patents and certifications that cover products, manufacturing facilities and innovative technologies. Reliable and Quality Manufacturing NOARK Electric always selects qualified suppliers to cooperate with. We are concertned on a large degree about the whole production process, including molding, welding, assembly, quality control, etc. because we share the same value proposition of presenting world class quallity to our customers. We hold this philosohy of ‘Makeing low voltage electrical products in the way of automobile NOARK Electric NOARK always selects suppliers cooperate with. We system are concertned on afrom large manufacuring.” Electricqualified obtained ISO9001toquality management certification degree about the wholeAssurance production process, including molding, welding, assembly, quality control, Lloyds Register Quality and became one of the low-voltage eletrical manufacurers being etc. because the same value proposition of presenting world class quallity to our customers. awarded withwe thisshare certification. We hold this philosohy of ‘Makeing low voltage electrical products in the way of automobile manufacuring.” NOARK Electric obtained ISO9001 quality management system certification from Lloyds Register Quality Assurance and became one of the low-voltage eletrical manufacurers being awarded with this certification. iii 2013 NOARK Electric • All Rights Reserved Contents A Moulded Case Circuit Breakers.................................................... A-1 - A-14 Product Overview.......................................................................................... A-1 Product Selection............................................................................... A-2 - A-10 Specifications................................................................................... A-11 - A-13 Dimensions.................................................................................................. A-14 B Moulded Case Switches...................................................................B-1- B-8 Product Overview..................................................................................B-1 - B-2 Product Selection..................................................................................B-3 - B-6 Specifications................................................................................................ B-7 Dimensions.................................................................................................... B-8 C Accessories.................................................................................. C-1 - C-11 Product Overview................................................................................. C-1 - C-4 Product Selection................................................................................. C-5 - C-7 Connection Diagrams.................................................................................... C-8 Dimensions......................................................................................... C-9 - C-11 2013 NOARK Electric • All Rights Reserved iv Header Here No. v Definition Abbreviation 1 Auxiliary / alarm contact 2 Undervoltage release UVT 3 Shunt release SHT 4 Direct rotary handle RHD 5 Plug-in base PIA 6 Motor mechanism MOD 7 Extended rotary handle ERH 8 Rear connection plate RCP 9 Mechanical interlock MIT 10 Handle lock KLK 11 Draw-out base DOB 11 AX / AL 2013 NOARK Electric • All Rights Reserved 9 8 10 2013 NOARK Electric • All Rights Reserved vi Molded Case Circuit Breaker Product Overview A Features • Field-fit accessories • Common accessories through 630A • Space-saving footprint • High-performance current limiting designs up to 100 kA at 240 V • Complete breaker includes frame, trip unit, standard terminals and mounting hardware Complies with the Latest National and International Standards Standards – Feeder and Branch Circuit Protection UL 489/CSA C22.2 No.5; IEC60947-2 Standard for molded case circuit breakers (MCCB) for feeder and branch circuit protection. • CSA (Canadian Standards Association) C22.2 No. 5-02 standard for branch circuit protection. • UL 489A requirements covering single pole DC circuit breakers intended for use as a branch circuit overcurrent and short circuit protection in communications equipment. • UL 486 standard for connection terminals which allows the user to apply field wiring directly to the breaker. • IEC 60947-2 standard for industrial applications of circuit protection. RoHS • These devices are RoHS compliant. Breakers have UL 486 rated connectors which means the breakers can be wired directly to the load without the need for terminal strips. Catalog Number Selection Guide M 1 S 100 T 3 L 1 A NOARK Ex9M Series Frame size Interrupting ratings Amperage Trip unit Poles Terminations Accessories Control voltage 1: 100 A S: M1/M2: 50 kA @ 240 Vac M3/M4: 65 kA @ 240 Vac M1: 15 - 100 A T:Thermalmagnetic 2: 2 poles Blank:Bus bar connection M2: 100 - 225 A E:Electronic 3: 3 poles L: Line / load box lugs 1: Shunt trip 2: Auxiliary switch 3:Undervoltage release 4: Alarm switch 5:Lugs 6: Motor operator 7: Rotary handle 8:Interlock 9: Handle padlock 10:Door mounted rotary handle 2: 225 A 3: 400 A N:100 kA @ 240 Vac 4: 600 A M3: 225 - 400 A P:Plug-in M4: 400 - 600 A D:Draw-out R:Rear connection 2013 NOARK Electric • All Rights Reserved A: M: C: D: G: 100-130 Vac 110-127 Vac 220-240 Vac 380-440 Vac 480-500 Vac H: S: T: K: U: X: F: 24 Vdc 24-30 Vdc 48 Vdc 48-60 Vdc 60 Vdc 110-125 Vdc 220-250 Vdc MD:120 Vac/dc CD: 240 Vac/dc A-1 Molded Case Circuit Breaker Product Selection Rated amp 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A A-2 Voltage Tripping unit Pole Connection type 50 kA @ 240 Vac 22 kA @ 480 Vac 10 kA @ 600Y/347 Vac 20 kA @ 600 Vdc Thermal-magnetic 3 poles Bus bar connection 100 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc Thermal-magnetic 3 poles Bus bar connection Thermal-magnetic 3 poles With lug terminal Thermal-magnetic 3 poles With lug terminal 50 kA @ 240 Vac 22 kA @ 480 Vac 10 kA @ 600Y/347 Vac 20 kA @ 600 Vdc 100 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc Catalog number M1S15T3 M1S20T3 M1S25T3 M1S30T3 M1S35T3 M1S40T3 M1S45T3 M1S50T3 M1S60T3 M1S70T3 M1S80T3 M1S90T3 M1S100T3 M1N15T3 M1N20T3 M1N25T3 M1N30T3 M1N35T3 M1N40T3 M1N45T3 M1N50T3 M1N60T3 M1N70T3 M1N80T3 M1N90T3 M1N100T3 M1S15T3L M1S20T3L M1S25T3L M1S30T3L M1S35T3L M1S40T3L M1S45T3L M1S50T3L M1S60T3L M1S70T3L M1S80T3L M1S90T3L M1S100T3L M1N15T3L M1N20T3L M1N25T3L M1N30T3L M1N35T3L M1N40T3L M1N45T3L M1N50T3L M1N60T3L M1N70T3L M1N80T3L M1N90T3L M1N100T3L 2013 NOARK Electric • All Rights Reserved Molded Case Circuit Breaker Product Selection Rated amp 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A A Voltage Tripping unit Pole Connection type 50 kA @ 240 Vac 22 kA @ 480 Vac 10 kA @ 600Y/347 Vac 20 kA @ 600 Vdc Thermal-magnetic 3 poles Plug-in type 100 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc Thermal-magnetic 3 poles Plug-in type Thermal-magnetic 3 poles Rear connection Thermal-magnetic 3 poles Rear connection 50 kA @ 240 Vac 22 kA @ 480 Vac 10 kA @ 600Y/347 Vac 20 kA @ 600 Vdc 100 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc 2013 NOARK Electric • All Rights Reserved Catalog number M1S15T3P M1S20T3P M1S25T3P M1S30T3P M1S35T3P M1S40T3P M1S45T3P M1S50T3P M1S60T3P M1S70T3P M1S80T3P M1S90T3P M1S100T3P M1N15T3P M1N20T3P M1N25T3P M1N30T3P M1N35T3P M1N40T3P M1N45T3P M1N50T3P M1N60T3P M1N70T3P M1N80T3P M1N90T3P M1N100T3P M1S15T3R M1S20T3R M1S25T3R M1S30T3R M1S35T3R M1S40T3R M1S45T3R M1S50T3R M1S60T3R M1S70T3R M1S80T3R M1S90T3R M1S100T3R M1N15T3R M1N20T3R M1N25T3R M1N30T3R M1N35T3R M1N40T3R M1N45T3R M1N50T3R M1N60T3R M1N70T3R M1N80T3R M1N90T3R M1N100T3R A-3 Molded Case Circuit Breaker Product Selection Rated amp 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A A-4 Voltage Tripping unit Pole Connection type 50 kA @ 240 Vac 22 kA @ 480 Vac 10 kA @ 600Y/347 Vac 20 kA @ 600 Vdc Thermal-magnetic 2 poles Bus bar connection 100 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc Thermal-magnetic 2 poles Bus bar connection Thermal-magnetic 2 poles With lug terminal Thermal-magnetic 2 poles With lug terminal 50 kA @ 240 Vac 22 kA @ 480 Vac 10 kA @ 600Y/347 Vac 20 kA @ 600 Vdc 100 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc Catalog number M1S15T2 M1S20T2 M1S25T2 M1S30T2 M1S35T2 M1S40T2 M1S45T2 M1S50T2 M1S60T2 M1S70T2 M1S80T2 M1S90T2 M1S100T2 M1N15T2 M1N20T2 M1N25T2 M1N30T2 M1N35T2 M1N40T2 M1N45T2 M1N50T2 M1N60T2 M1N70T2 M1N80T2 M1N90T2 M1N100T2 M1S15T2L M1S20T2L M1S25T2L M1S30T2L M1S35T2L M1S40T2L M1S45T2L M1S50T2L M1S60T2L M1S70T2L M1S80T2L M1S90T2L M1S100T2L M1N15T2L M1N20T2L M1N25T2L M1N30T2L M1N35T2L M1N40T2L M1N45T2L M1N50T2L M1N60T2L M1N70T2L M1N80T2L M1N90T2L M1N100T2L 2013 NOARK Electric • All Rights Reserved Molded Case Circuit Breaker Product Selection Rated amp 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A Voltage 50 kA @ 240 Vac 22 kA @ 480 Vac 10 kA @ 600Y/347 Vac 20 kA @ 600 Vdc 100 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc 50 kA @ 240 Vac 22 kA @ 480 Vac 10 kA @ 600Y/347 Vac 20 kA @ 600 Vdc 100 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc 2013 NOARK Electric • All Rights Reserved A Tripping unit Pole Connection type Thermal-magnetic 2 poles Plug-in type Thermal-magnetic 2 poles Plug-in type Thermal-magnetic 2 poles Rear connection Thermal-magnetic 2 poles Rear connection Catalog number M1S15T2P M1S20T2P M1S25T2P M1S30T2P M1S35T2P M1S40T2P M1S45T2P M1S50T2P M1S60T2P M1S70T2P M1S80T2P M1S90T2P M1S100T2P M1N15T2P M1N20T2P M1N25T2P M1N30T2P M1N35T2P M1N40T2P M1N45T2P M1N50T2P M1N60T2P M1N70T2P M1N80T2P M1N90T2P M1N100T2P M1S15T2R M1S20T2R M1S25T2R M1S30T2R M1S35T2R M1S40T2R M1S45T2R M1S50T2R M1S60T2R M1S70T2R M1S80T2R M1S90T2R M1S100T2R M1N15T2R M1N20T2R M1N25T2R M1N30T2R M1N35T2R M1N40T2R M1N45T2R M1N50T2R M1N60T2R M1N70T2R M1N80T2R M1N90T2R M1N100T2R A-5 Molded Case Circuit Breaker Product Selection Rated amp 100 A 125 A 150 A 175 A 200 A 225 A 100 A 125 A 150 A 175 A 200 A 225 A 100 A 125 A 150 A 175 A 200 A 225 A 100 A 125 A 150 A 175 A 200 A 225 A 100 A 125 A 150 A 175 A 200 A 225 A 100 A 125 A 150 A 175 A 200 A 225 A 100 A 125 A 150 A 175 A 200 A 225 A 100 A 125 A 150 A 175 A 200 A 225 A A-6 Voltage Tripping unit Pole Connection type 50 kA @ 240 Vac 25 kA @ 480 Vac 10 kA @ 600Y/347 Vac 20 kA @ 600 Vdc Thermal-magnetic 3 poles Bus bar connection 100 kA @ 240 Vac 42 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc Thermal-magnetic 3 poles Bus bar connection 50 kA @ 240 Vac 25 kA @ 480 Vac 10 kA @ 600Y/347 Vac 20 kA @ 600 Vdc Thermal-magnetic 3 poles With lug terminal 100 kA @ 240 Vac 42 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc Thermal-magnetic 3 poles With lug terminal 50 kA @ 240 Vac 25 kA @ 480 Vac 10 kA @ 600Y/347 Vac 20 kA @ 600 Vdc Thermal-magnetic 3 poles Plug-in type 100 kA @ 240 Vac 42 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc Thermal-magnetic 3 poles Plug-in type 50 kA @ 240 Vac 25 kA @ 480 Vac 10 kA @ 600Y/347 Vac 20 kA @ 600 Vdc Thermal-magnetic 3 poles Rear connection 100 kA @ 240 Vac 42 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc Thermal-magnetic 3 poles Rear connection Catalog number M2S100T3 M2S125T3 M2S150T3 M2S175T3 M2S200T3 M2S225T3 M2N100T3 M2N125T3 M2N150T3 M2N175T3 M2N200T3 M2N225T3 M2S100T3L M2S125T3L M2S150T3L M2S175T3L M2S200T3L M2S225T3L M2N100T3L M2N125T3L M2N150T3L M2N175T3L M2N200T3L M2N225T3L M2S100T3P M2S125T3P M2S150T3P M2S175T3P M2S200T3P M2S225T3P M2N100T3P M2N125T3P M2N150T3P M2N175T3P M2N200T3P M2N225T3P M2S100T3R M2S125T3R M2S150T3R M2S175T3R M2S200T3R M2S225T3R M2N100T3R M2N125T3R M2N150T3R M2N175T3R M2N200T3R M2N225T3R 2013 NOARK Electric • All Rights Reserved Molded Case Circuit Breaker Product Selection Rated amp 100 A 125 A 150 A 175 A 200 A 225 A 100 A 125 A 150 A 175 A 200 A 225 A 100 A 125 A 150 A 175 A 200 A 225 A 100 A 125 A 150 A 175 A 200 A 225 A 100 A 125 A 150 A 175 A 200 A 225 A 100 A 125 A 150 A 175 A 200 A 225 A 100 A 125 A 150 A 175 A 200 A 225 A 100 A 125 A 150 A 175 A 200 A 225 A A Voltage Tripping unit Pole Connection type 50 kA @ 240 Vac 25 kA @ 480 Vac 10 kA @ 600Y/347 Vac 20 kA @ 600 Vdc Thermal-magnetic 2 poles Bus bar connection 100 kA @ 240 Vac 42 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc Thermal-magnetic 2 poles Bus bar connection 50 kA @ 240 Vac 25 kA @ 480 Vac 10 kA @ 600Y/347 Vac 20 kA @ 600 Vdc Thermal-magnetic 2 poles With lug terminal 100 kA @ 240 Vac 42 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc Thermal-magnetic 2 poles With lug terminal 50 kA @ 240 Vac 25 kA @ 480 Vac 10 kA @ 600Y/347 Vac 20 kA @ 600 Vdc Thermal-magnetic 2 poles Plug-in type 100 kA @ 240 Vac 42 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc Thermal-magnetic 2 poles Plug-in type 50 kA @ 240 Vac 25 kA @ 480 Vac 10 kA @ 600Y/347 Vac 20 kA @ 600 Vdc Thermal-magnetic 2 poles Rear connection 100 kA @ 240 Vac 42 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc Thermal-magnetic 2 poles Rear connection 2013 NOARK Electric • All Rights Reserved Catalog number M2S100T2 M2S125T2 M2S150T2 M2S175T2 M2S200T2 M2S225T2 M2N100T2 M2N125T2 M2N150T2 M2N175T2 M2N200T2 M2N225T2 M2S100T2L M2S125T2L M2S150T2L M2S175T2L M2S200T2L M2S225T2L M2N100T2L M2N125T2L M2N150T2L M2N175T2L M2N200T2L M2N225T2L M2S100T2P M2S125T2P M2S150T2P M2S175T2P M2S200T2P M2S225T2P M2N100T2P M2N125T2P M2N150T2P M2N175T2P M2N200T2P M2N225T2P M2S100T2R M2S125T2R M2S150T2R M2S175T2R M2S200T2R M2S225T2R M2N100T2R M2N125T2R M2N150T2R M2N175T2R M2N200T2R M2N225T2R A-7 Molded Case Circuit Breaker Product Selection Rated amp 225 A 250 A 300 A 350 A Voltage Tripping unit Pole Connection type 65 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600 Vac 35 kA @ 600 Vdc Thermal-magnetic 3 poles Bus bar connection 225 A 250 A 300 A 350 A 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 600 Vdc 400 A 400 A 225 A 250 A 300 A 350 A 400 A 225 A 250 A 300 A 350 A 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 600 Vdc 225 A 250 A 300 A 350 A 65 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600 Vac 35 kA @ 600 Vdc 400 A 400 A 225 A 250 A 300 A 350 A 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 600 Vdc 225 A 250 A 300 A 350 A 65 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600 Vac 35 kA @ 600 Vdc 400 A 400 A 225 A 250 A 300 A 350 A 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 600 Vdc 225 A 250 A 300 A 350 A 65 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600 Vac 35 kA @ 600 Vdc 400 A 400 A 225 A 250 A 300 A 350 A 400 A A-8 65 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600 Vac 35 kA @ 600 Vdc 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 600 Vdc Catalog number M3S225T3 M3S250T3 M3S300T3 M3S350T3 M3S400T3 Thermal-magnetic 3 poles Bus bar connection M3N225T3 M3N250T3 M3N300T3 M3N350T3 M3N400T3 Thermal-magnetic 3 poles With lug terminal M3S225T3L M3S250T3L M3S300T3L M3S350T3L M3S400T3L Thermal-magnetic 3 poles With lug terminal M3N225T3L M3N250T3L M3N300T3L M3N350T3L M3N400T3L Thermal-magnetic 3 poles Plug-in type M3S225T3P M3S250T3P M3S300T3P M3S350T3P M3S400T3P Thermal-magnetic 3 poles Plug-in type M3N225T3P M3N250T3P M3N300T3P M3N350T3P M3N400T3P Thermal-magnetic 3 poles Rear connection M3S225T3R M3S250T3R M3S300T3R M3S350T3R M3S400T3R Thermal-magnetic 3 poles Rear connection M3N225T3R M3N250T3R M3N300T3R M3N350T3R M3N400T3R Thermal-magnetic 3 poles Draw-out type M3S225T3D M3S250T3D M3S300T3D M3S350T3D M3S400T3D Thermal-magnetic 3 poles Draw-out type M3N225T3D M3N250T3D M3N300T3D M3N350T3D M3N400T3D 2013 NOARK Electric • All Rights Reserved Molded Case Circuit Breaker Product Selection A Rated amp 225 A 250 A 300 A 350 A Voltage Tripping unit Pole Connection type 65 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600 Vac 35 kA @ 600 Vdc Thermal-magnetic 2 pole Bus bar connection 225 A 250 A 300 A 350 A 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 600 Vdc 400 A 400 A 225 A 250 A 300 A 350 A 400 A 65 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600 Vac 35 kA @ 600 Vdc 225 A 250 A 300 A 350 A 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 600 Vdc 225 A 250 A 300 A 350 A 65 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600 Vac 35 kA @ 600 Vdc 400 A 400 A 225 A 250 A 300 A 350 A 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 600 Vdc 225 A 250 A 300 A 350 A 65 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600 Vac 35 kA @ 600 Vdc 400 A 400 A 225 A 250 A 300 A 350 A 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 600 Vdc 225 A 250 A 300 A 350 A 65 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600 Vac 35 kA @ 600 Vdc 400 A 400 A 225 A 250 A 300 A 350 A 400 A 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 600 Vdc 2013 NOARK Electric • All Rights Reserved Catalog number M3S225T2 M3S250T2 M3S300T2 M3S350T2 M3S400T2 Thermal-magnetic 2 pole Bus bar connection M3N225T2 M3N250T2 M3N300T2 M3N350T2 M3N400T2 Thermal-magnetic 2 pole With lug terminal M3S225T2L M3S250T2L M3S300T2L M3S350T2L M3S400T2L Thermal-magnetic 2 pole With lug terminal M3N225T2L M3N250T2L M3N300T2L M3N350T2L M3N400T2L Thermal-magnetic 2 pole Plug-in type M3S225T2P M3S250T2P M3S300T2P M3S350T2P M3S400T2P Thermal-magnetic 2 pole Plug-in type M3N225T2P M3N250T2P M3N300T2P M3N350T2P M3N400T2P Thermal-magnetic 2 pole Rear connection M3S225T2R M3S250T2R M3S300T2R M3S350T2R M3S400T2R Thermal-magnetic 2 pole Rear connection M3N225T2R M3N250T2R M3N300T2R M3N350T2R M3N400T2R Thermal-magnetic 2 pole Draw-out type M3S225T2D M3S250T2D M3S300T2D M3S350T2D M3S400T2D Thermal-magnetic 2 pole Draw-out type M3N225T2D M3N250T2D M3N300T2D M3N350T2D M3N400T2D A-9 Molded Case Circuit Breaker Product Selection Rated amp 400 A 500 A 600 A 400 A 500 A 600 A 400 A 500 A 600 A 400 A 500 A 600 A 400 A 500 A 600 A 400 A 500 A 600 A 400 A 500 A 600 A 400 A 500 A 600 A 400 A 500 A 600 A 400 A 500 A 600 A 400 A 500 A 600 A 400 A 500 A 600 A 400 A 500 A 600 A 400 A 500 A 600 A 400 A 500 A 600 A 400 A 500 A 600 A A-10 Voltage 65 kA @ 240 Vac 42 kA @ 480 Vac 14 kA @ 600 Vac 35 kA @ 600 Vdc 100 kA @ 240 Vac 65 kA @ 480 Vac 18 kA @ 600 Vac 50 kA @ 600 Vdc 65 kA @ 240 Vac 42 kA @ 480 Vac 14 kA @ 600 Vac 35 kA @ 600 Vdc 100 kA @ 240 Vac 65 kA @ 480 Vac 18 kA @ 600 Vac 50 kA @ 600 Vdc 65 kA @ 240 Vac 42 kA @ 480 Vac 14 kA @ 600 Vac 35 kA @ 600 Vdc 100 kA @ 240 Vac 65 kA @ 480 Vac 18 kA @ 600 Vac 50 kA @ 600 Vdc 65 kA @ 240 Vac 42 kA @ 480 Vac 14 kA @ 600 Vac 35 kA @ 600 Vdc 100 kA @ 240 Vac 65 kA @ 480 Vac 18 kA @ 600 Vac 50 kA @ 600 Vdc 65 kA @ 240 Vac 42 kA @ 480 Vac 14 kA @ 600 Vac 35 kA @ 600 Vdc 100 kA @ 240 Vac 65 kA @ 480 Vac 18 kA @ 600 Vac 50 kA @ 600 Vdc 65 kA @ 240 Vac 42 kA @ 480 Vac 14 kA @ 600 Vac 35 kA @ 600 Vdc 100 kA @ 240 Vac 65 kA @ 480 Vac 18 kA @ 600 Vac 50 kA @ 600 Vdc 65 kA @ 240 Vac 42 kA @ 480 Vac 14 kA @ 600 Vac 35 kA @ 600 Vdc 100 kA @ 240 Vac 65 kA @ 480 Vac 18 kA @ 600 Vac 50 kA @ 600 Vdc 65 kA @ 240 Vac 42 kA @ 480 Vac 14 kA @ 600 Vac 35 kA @ 600 Vdc 100 kA @ 240 Vac 65 kA @ 480 Vac 18 kA @ 600 Vac 50 kA @ 600 Vdc Tripping unit Pole Connection type Catalog number Thermal-magnetic 3 poles Bus bar connection M4S500T3 M4S400T3 M4S600T3 M4N400T3 Thermal-magnetic 3 poles Bus bar connection M4N500T3 M4N600T3 M4S400T3L Thermal-magnetic 3 poles With lug terminal M4S500T3L M4S600T3L M4N400T3L Thermal-magnetic 3 poles With lug terminal M4N500T3L M4N600T3L M4S400T3R Thermal-magnetic 3 poles Rear connection M4S500T3R M4S600T3R M4N400T3R Thermal-magnetic 3 poles Rear connection M4N500T3R M4N600T3R M4S400T3D Thermal-magnetic 3 poles Draw-out type M4S500T3D M4S600T3D M4N400T3D Thermal-magnetic 3 poles Draw-out type M4N500T3D M4N600T3D M4S400T2 Thermal-magnetic 2 poles Bus bar connection M4S500T2 M4S600T2 M4N400T2 Thermal-magnetic 2 poles Bus bar connection M4N500T2 M4N600T2 M4S400T2L Thermal-magnetic 2 poles With lug terminal M4S500T2L M4S600T2L M4N400T2L Thermal-magnetic 2 poles With lug terminal M4N500T2L M4N600T2L M4S400T2R Thermal-magnetic 2 poles Rear connection M4S500T2R M4S600T2R M4N400T2R Thermal-magnetic 2 poles Rear connection M4N500T2R M4N600T2R M4S400T2D Thermal-magnetic 2 poles Draw-out type M4S500T2D M4S600T2D M4N400T2D Thermal-magnetic 2 poles Draw-out type M4N500T2D M4N600T2D 2013 NOARK Electric • All Rights Reserved Molded Case Circuit Breaker Specifications Item Model Maximum rated current (amperes) Number of poles Interrupting ratings 240 Vac M2 M3 M4 100 2, 3 225 2, 3 400 2, 3 600 2, 3 50 N S 100 50 N S 100 65 N S 100 65 N 100 480 Vac 22 35 25 42 35 50 42 65 10 10 10 10 10 14 14 18 - - - - 10 14 14 18 25 50 - - - - - - 500 Vdc 2 poles 600 Vdc 3 poles 20 35 20 35 35 50 35 50 220 / 240 Vac 50 100 50 100 65 100 65 100 380 / 415 Vac 50 100 50 100 65 100 65 100 660 / 690 Vac 5 8 6 10 10 15 12 15 25 50 25 50 - - - - - - - - 35 50 50 50 Ultimate breaking 500 Vdc 3 poles capacity (Icu = 100% Ics) (kA rms) 500 Vdc 2 poles Current rating @ 40 C Thermal magnetic trip units (fixed) S M1 600Y / 347 Vac Circuit breaker ratings UL 489 600 Vac CSA C22.2 (kA rms) Vac 50 / 60 Hz 250 Vdc 2 poles 500 Vdc 3 poles Circuit breaker ratings IEC 60947-2 A T = Thermal M = Magnetic A = Adjustable F = Fixed 2013 NOARK Electric • All Rights Reserved 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 100, 125, 150, 175, 200, 225 225, 250, 400 400, 500, 600 TA / MF TA / MA TA / MA TA / MA A-11 Molded Case Circuit Breaker Time / Current Curves M1 (In=15/20 A) M1 (In=80/90/100 A) M1 (In=25/30/35 A) M2 (In=100/125 A) M1 (In=40/45/50/60/70 A) M2 (In=150/175 A) A-12 2013 NOARK Electric • All Rights Reserved Molded Case Circuit Breaker Time / Current Curves M3 (In=225/250/300/350/400 A) 2013 NOARK Electric • All Rights Reserved A M4 (In=400/500/600 A) A-13 Molded Case Circuit Breaker Dimensions Unit: in. [mm] M1 M2 M3 M4 4X 0.26[4X 6.5] A-14 2013 NOARK Electric • All Rights Reserved Molded Case Switches Product Overview Features • XXXX B Complies with the Latest National and International Standards Standards – Feeder and Branch Circuit Protection UL 489/CSA C22.2 No.5; IEC60947-2 Standard for molded case circuit breakers (MCCB) for feeder and branch circuit protection. • CSA (Canadian Standards Association) C22.2 No. 5-02 standard for branch circuit protection. • UL 489A requirements covering single pole DC circuit breakers intended for use as a branch circuit overcurrent and short circuit protection in communications equipment. • UL 486 standard for connection terminals which allows the user to apply field wiring directly to the breaker. • IEC 60947-2 standard for industrial applications of circuit protection. RoHS • These devices are RoHS compliant. Breakers have UL 486 rated connectors which means the breakers can be wired directly to the load without the need for terminal strips. 2013 NOARK Electric • All Rights Reserved B-1 Molded Case Switches Catalog Number Selection Guide M 1 D 100 T 3 NOARK Ex9M Series Frame rating Protection type Current rating Tripping unit Poles Installation type 1: 100 A D: Disconnector M1: 15 - 100 A T:Thermalmagnetic 2: 2 poles Blank:Bus bar connection 2: 225 A M2: 60 - 225 A E:Electronic 3: 3 poles L: Line / load box lugs 3: 400 A M3: 225 - 400 A P:Plug-in 4: 600 A M4: 400 - 600 A D:Draw-out L R:Rear connection B-2 1 A Accessories Control voltage 1: Shunt release contacts 2: Aux contacs 3:Undervoltage contacts 4: Alarm contacts 5: UL approved lugs 6: Motor operator 7: Rotary manual operator 8:Interlock 9: Pad lock (on/off standard) 10:Extend rotary manual operator A: 100-130 Vac H: 24 Vdc M: 110-127 Vac T: 48 Vdc X: 110-125 Vdc D: 380-440 Vac MD:120 Vac/dc G: 480-500 Vac K: 48-60 Vdc S: 24-30 Vdc U: 60 Vdc C: 220-240 Vac F: 220-250 Vdc CD: 240 Vac/dc 2013 NOARK Electric • All Rights Reserved Molded Case Switches Product Selection Rated amp 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A Voltage Poles Connection type 100 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc 3 poles Bus bar connection 100 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc 3 poles With lug terminal 100 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc 3 poles Plug-in type 100 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc 3 poles Rear connection 2013 NOARK Electric • All Rights Reserved Catalog number M1D153 M1D203 M1D253 M1D303 M1D353 M1D403 M1D453 M1D503 M1D603 M1D703 M1D803 M1D903 M1D1003 M1D153L M1D203L M1D253L M1D303L M1D353L M1D403L M1D453L M1D503L M1D603L M1D703L M1D803L M1D903L M1D1003L M1D153P M1D203P M1D253P M1D303P M1D353P M1D403P M1D453P M1D503P M1D603P M1D703P M1D803P M1D903P M1D1003P M1D153R M1D203R M1D253R M1D303R M1D353R M1D403R M1D453R M1D503R M1D603R M1D703R M1D803R M1D903R M1D1003R B B-3 Molded Case Switches Product Selection Rated amp 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A 15 A 20 A 25 A 30 A 35 A 40 A 45 A 50 A 60 A 70 A 80 A 90 A 100 A B-4 Voltage Poles Connection type 100 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 500 Vdc 2 poles Bus bar connection 100 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 500 Vdc 2 poles With lug terminal 100 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 500 Vdc 2 poles Plug-in type 100 kA @ 240 Vac 35 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 500 Vdc 2 poles Rear connection Catalog number M1D152 M1D202 M1D252 M1D302 M1D352 M1D402 M1D452 M1D502 M1D602 M1D702 M1D802 M1D902 M1D1002 M1D152L M1D202L M1D252L M1D302L M1D352L M1D402L M1D452L M1D502L M1D602L M1D702L M1D802L M1D902L M1D1002L M1D152P M1D202P M1D252P M1D302P M1D352P M1D402P M1D452P M1D502P M1D602P M1D702P M1D802P M1D902P M1D1002P M1D152R M1D202R M1D252R M1D302R M1D352R M1D402R M1D452R M1D502R M1D602R M1D702R M1D802R M1D902R M1D1002R 2013 NOARK Electric • All Rights Reserved Molded Case Switches Product Selection Rated amp 125 A 150 A 225 A 125 A 150 A 225 A 125 A 150 A 225 A 125 A 150 A 225 A 125 A 150 A 225 A 125 A 150 A 225 A 125 A 150 A 225 A 125 A 150 A 225 A 250 A 400 A 250 A 400 A 250 A 400 A 250 A 400 A 250 A 400 A 250 A 400 A 250 A 400 A 250 A 400 A 250 A 400 A 250 A 400 A Voltage 100 kA @ 240 Vac 42 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc 100 kA @ 240 Vac 42 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc 100 kA @ 240 Vac 42 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc 100 kA @ 240 Vac 42 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 600 Vdc 100 kA @ 240 Vac 42 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 500 Vdc 100 kA @ 240 Vac 42 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 500 Vdc 100 kA @ 240 Vac 42 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 500 Vdc 100 kA @ 240 Vac 42 kA @ 480 Vac 10 kA @ 600Y/347 Vac 35 kA @ 500 Vdc 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 600 Vdc 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 600 Vdc 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 600 Vdc 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 600 Vdc 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 500 Vdc 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 500 Vdc 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 500 Vdc 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 500 Vdc 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 500 Vdc 100 kA @ 240 Vac 50 kA @ 480 Vac 14 kA @ 600 Vac 50 kA @ 500 Vdc 2013 NOARK Electric • All Rights Reserved Poles Connection type 3 poles Bus bar connection 3 poles With lug terminal 3 poles Plug-in type 3 poles Rear connection 2 poles Bus bar connection 2 poles With lug terminal 2 poles Plug-in type 2 poles Rear connection 3 poles Bus bar connection 3 poles With lug terminal 3 poles Plug-in type 3 poles Rear connection 3 poles Draw-out type 2 poles Bus bar connection 2 poles With lug terminal 2 poles Plug-in type 2 poles Rear connection 2 poles Draw-out type Catalog number M2D1253 M2D1503 M2D2253 M2D1253L M2D1503L M2D2253L M2D1253P M2D1503P M2D2253P M2D1253R M2D1503R M2D2253R M2D1252 M2D1502 M2D2252 M2D1252L M2D1502L M2D2252L M2D1252P M2D1502P M2D2252P M2D1252R M2D1502R M2D2252R B M3D2503 M3D4003 M3D2503L M3D4003L M3D2503P M3D4003P M3D2503R M3D4003R M3D2503D M3D4003D M3D2502 M3D4002 M3D2502L M3D4002L M3D2502P M3D4002P M3D2502R M3D4002R M3D2502D M3D4002D B-5 Molded Case Switches Product Selection Rated amp 600 A 600 A 600 A 600 A 600 A 600 A 600 A 600 A B-6 Voltage 100 kA @ 240 Vac 65 kA @ 480 Vac 18 kA @ 600 Vac 50 kA @ 500 Vdc 100 kA @ 240 Vac 65 kA @ 480 Vac 18 kA @ 600 Vac 50 kA @ 500 Vdc 100 kA @ 240 Vac 65 kA @ 480 Vac 18 kA @ 600 Vac 50 kA @ 500 Vdc 100 kA @ 240 Vac 65 kA @ 480 Vac 18 kA @ 600 Vac 50 kA @ 500 Vdc 100 kA @ 240 Vac 65 kA @ 480 Vac 18 kA @ 600 Vac 50 kA @ 500 Vdc 100 kA @ 240 Vac 65 kA @ 480 Vac 18 kA @ 600 Vac 50 kA @ 500 Vdc 100 kA @ 240 Vac 65 kA @ 480 Vac 18 kA @ 600 Vac 50 kA @ 500 Vdc 100 kA @ 240 Vac 65 kA @ 480 Vac 18 kA @ 600 Vac 50 kA @ 500 Vdc Poles Connection type Catalog number 3 poles Bus bar connection M4D6003 3 poles With lug terminal M4D6003L 3 poles Rear connection M4D6003R 3 poles Draw-out type M4D6003D 2 poles Bus bar connection M4D6002 2 poles With lug terminal M4D6002L 2 poles Rear connection M4D6002R 2 poles Draw-out type M4D6002D 2013 NOARK Electric • All Rights Reserved Molded Case Switches Specifications Item Model Maximum rated current (amperes) Breaker type Number of poles Interrupting Capacity (kA rms) Vac 50 / 60 Hz NEMA UL, CSA IEC 60947-2 Icu=100% Ics S 100 2, 3 - M2 N S 225 2, 3 - M3 N S 400 2, 3 - M4 N S 600 2, 3 - N 240 Vac 50 100 50 100 65 100 65 100 480Y/277 Vac 480 Vac 600Y/347 Vac 600 Vac 250 Vdc 2 poles / 500 Vdc 3 poles 500 Vdc 2 poles / 600 Vdc 3 poles 220-240 Vac 380-415 Vac 660-690 Vac 500 Vdc 3 poles 500 Vdc 2 poles 22 22 10 - 35 35 10 - 25 25 10 - 42 42 10 - 35 35 10 10 50 50 14 14 42 42 14 14 65 65 18 18 25 50 - - - - - - 20 35 20 35 35 50 35 50 50 50 6 25 - 100 100 10 50 - 65 65 10 35 100 100 15 50 65 65 12 50 100 100 15 50 Rated Current (A) Trip Units M1 F = Fixed A = Adjustable T = Thermal M = Magnetic Built-in Interchangable 2013 NOARK Electric • All Rights Reserved 50 100 50 100 5 8 25 50 15, 20, 25, 30, 35, 40, 45, 50, 60, 70, 80, 90, 100 100, 125, 150, 175, 200, 225 225, 250, 400 400, 500, 600 TA / MA TA / MA TA / MA TA / MF ■ ■ ■ ■ ■ Available, please contact sales ■ ■ B ■ B-7 Molded Case Switches Dimensions Unit: in. [mm] M1 M2 M3 M4 4X 0.26[4X 6.5] B-8 2013 NOARK Electric • All Rights Reserved Molded Case Accessories Product Overview External Accessories 1 Mechanical interlock (MIT) 2 Position locking device (KLK) 3 Motor operator (MOD) 4 Rotary handle (RHD) 5 Extended rotary handle (ERH) 1 2 4 C 3 5 7 6 10 11 8 Internal Accessories 6 Aux contacts (AX) 7 Alarm contacts (AL) 8 Shunt trip (SHT) 9 Undervoltage trip (UVT) 2013 NOARK Electric • All Rights Reserved 9 12 Connection Accessories 10Plug-in base (PIA) 11Rear connection kit (RCP) 12 Box lugs termianls (LTC) C-1 Molded Case Accessories Catalog Number Selection Guide SHT 21 N A Code Application for MCCB Applicable device category Control voltage Shunt trip 21:for M1 N: UL 489 approval 22:for M2 & M3 24:for M4 A: 100-130 Vac B: 220-240 Vac C: 380-440 Vac D: 480-500 Vac E: 24 Vdc F: 48-60 Vdc G: 110-125 Vdc H: 220-250 Vdc UVT 21 N A Code Application for MCCB Applicable device category Control voltage Undervoltage trip 21:for M1 N: UL 489 approval 22:for M2 & M3 24:for M4 A: 110-127 Vac B: 220-240 Vac C: 380-440 Vac D: 24-30 Vdc E: 48 Vdc F: 60 Vdc G: 110-125 Vdc H: 220-250 Vdc MOD 21 N A Code Application for MCCB Applicable device category Rated voltage Motor operator 21:for M1 N: UL 489 approval A: 120 Vac/dc 22:for M2 B: 240 Vac/dc 23:for M3 C: 24 Vdc 24:for M4 KLK 21 N A Code Application for MCCB Applicable device category Rated voltage Position locking device 21:for M1 N: UL 489 approval A:Off 22:for M2 B:On/Off 23:for M3 C:On 24:for M4 C-2 2013 NOARK Electric • All Rights Reserved Molded Case Accessories Catalog Number Selection Guide ERH 21 N Code Application for MCCB Applicable device category Extended rotary handle 21:for M1 N: UL 489 approval 22:for M2 23:for M3 C 24:for M4 DOB 23 N Code Application for MCCB Applicable device category Draw-out base 23:for M3 N: UL 489 approval 24:for M4 RHD 21 N Code Application for MCCB Applicable device category Rotary handle 21:for M1 N: UL 489 approval 22:for M2 23:for M3 24:for M4 RPC 21 N Code Application for MCCB Applicable device category Rear connection kit 21:for M1 N: UL 489 approval 22:for M2 23:for M3 24:for M4 2013 NOARK Electric • All Rights Reserved C-3 Molded Case Accessories Catalog Number Selection Guide MIT 21 N A Code Application for MCCB Applicable device category Rated voltage N: UL 489 approval A: Distance of two MCCBs Mechanical interlock 21:for M1 22:for M2 B: Distance of two MCCBs 23:for M3 C: Distance of two MCCBs 24:for M4 LTC 21 N A Code Application for MCCB Applicable device category Rated voltage N: UL 489 approval A: 1 hole (M1 / M2 / M3) MCCB box lug terminals 21:for M1 B: 2 hole (M3 / M4) 22:for M2 23:for M3 24:for M4 PIA 21 N Code Application for MCCB Applicable device category Plug-in base 21:for M1 N: UL 489 approval 22:for M2 23:for M3 AX 21 N Code Application for MCCB Applicable device category 21:for M1, M2, M3 & M4 N: UL 489 approval AL 21 N Code Application for MCCB Applicable device category 21:for M1, M2, M3 & M4 N: UL 489 approval Aux contact Alarm contact C-4 2013 NOARK Electric • All Rights Reserved Molded Case Accessories Product Selection Catalog number SHT21NA SHT21NB SHT21NC SHT21ND SHT21NE SHT21NF SHT21NG SHT21NH SHT22NA SHT22NB SHT22NC SHT22ND SHT22NE SHT22NF SHT22NG SHT22NH SHT24NA SHT24NB SHT24NC SHT24ND SHT24NE SHT24NF SHT24NG SHT24NH Product description UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip UL 489 Shunt trip M1 M1 M1 M1 M1 M1 M1 M1 M2-M3 M2-M3 M2-M3 M2-M3 M2-M3 M2-M3 M2-M3 M2-M3 M4 M4 M4 M4 M4 M4 M4 M4 100-130 Vac 220-240 Vac 380-440 Vac 480-500 Vac 24 Vdc 48-60 Vdc 110-125 Vdc 220-250 Vdc 100-130 Vac 220-240 Vac 380-440 Vac 480-500 Vac 24 Vdc 48-60 Vdc 110-125 Vdc 220-250 Vdc 100-130 Vac 220-240 Vac 380-440 Vac 480-500 Vac 24 Vdc 48-60 Vdc 110-125 Vdc 220-250 Vdc Catalog number UVT21NA UVT21NB UVT21NC UVT21ND UVT21NE UVT21NF UVT21NG UVT21NH UVT22NA UVT22NB UVT22NC UVT22ND UVT22NE UVT22NF UVT22NG UVT22NH UVT24NA UVT24NB UVT24NC UVT24ND UVT24NE UVT24NF UVT24NG UVT24NH Product description UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip UL 489 Undervoltage Trip M1 M1 M1 M1 M1 M1 M1 M1 M2-M3 M2-M3 M2-M3 M2-M3 M2-M3 M2-M3 M2-M3 M2-M3 M4 M4 M4 M4 M4 M4 M4 M4 110-127 Vac 220-240 Vac 380-440 Vac 24-30 Vdc 48 Vdc 60 Vdc 110-125 Vdc 220-250 Vdc 110-127 Vac 220-240 Vac 380-440 Vac 24-30 Vdc 48 Vdc 60 Vdc 110-125 Vdc 220-250 Vdc 110-127 Vac 220-240 Vac 380-440 Vac 24-30 Vdc 48 Vdc 60 Vdc 110-125 Vdc 220-250 Vdc 2013 NOARK Electric • All Rights Reserved C C-5 Molded Case Accessories Product Selection C-6 Catalog number AX21N Product description UL489 Auxiliary contact Catalog number AL21N Product description UL 489 Alarm contact Catalog number RHD21N RHD22N RHD23N RHD24N Product description UL 489 Rotary Handle UL 489 Rotary Handle UL 489 Rotary Handle UL 489 Rotary Handle M1 M2 M3 M4 Catalog number ERH21N ERH22N ERH23N ERH24N Product description UL 489 Extended Rotary Handle UL 489 Extended Rotary Handle UL 489 Extended Rotary Handle UL 489 Extended Rotary Handle M1 M2 M3 M4 Catalog number MOD21NA MOD21NB MOD21NC MOD22NA MOD22NB MOD22NC MOD23NA MOD23NB MOD23NC MOD24NA MOD24NB MOD24NC Product description UL 489 Motor operator UL 489 Motor operator UL 489 Motor operator UL 489 Motor operator UL 489 Motor operator UL 489 Motor operator UL 489 Motor operato UL 489 Motor operator UL 489 Motor operator UL 489 Motor operator UL 489 Motor operator UL 489 Motor operator M1 M1 M1 M2 M2 M2 M3 M3 M3 M4 M4 M4 120 Vac/dc 240 Vac/dc 24 Vdc 120 Vac/dc 240 Vac/dc 24 Vdc 120 Vac/dc 240 Vac/dc 24 Vdc 120 Vac/dc 240 Vac/dc 24 Vdc Catalog number KLK21NA KLK21NB KLK21NC KLK22NA KLK22NB KLK22NC KLK23NA KLK23NB KLK23NC KLK24NA KLK24NB KLK24NC Product description UL 489 Position locking device UL 489 Position locking device UL 489 Position locking device UL 489 Position locking device UL 489 Position locking device UL 489 Position locking device UL 489 Position locking device UL 489 Position locking device UL 489 Position locking device UL 489 Position locking device UL 489 Position locking device UL 489 Position locking device M1 M1 M1 M2 M2 M2 M3 M3 M3 M4 M4 M4 Off On/Off On Off On/Off On Off On/Off On Off On/Off On 2013 NOARK Electric • All Rights Reserved Molded Case Accessories Product Selection Catalog number RCP21N RCP22N RCP23N RCP24N Product description UL 489 Rear Connection Kit UL 489 Rear Connection Kit UL 489 Rear Connection Kit UL 489 Rear Connection Kit M1 M2 M3 M4 Catalog number PIA21N PIA22N PIA23N Product description UL 489 Plug-in Base UL 489 Plug-in Base UL 489 Plug-in Base M1 M2 M3 Catalog number DOB23N DOB24N Product description UL 489 Draw-out Base UL 489 Draw-out Base M3 M4 Catalog number MIT21NA MIT21NB MIT21NC MIT22NA MIT22NB MIT22NC MIT23NA MIT23NB MIT23NC MIT24NA MIT24NB MIT24NC Product description UL 489 Mechanical Interlock UL 489 Mechanical Interlock UL 489 Mechanical Interlock UL 489 Mechanical Interlock UL 489 Mechanical Interlock UL 489 Mechanical Interlock UL 489 Mechanical Interlock UL 489 Mechanical Interlock UL 489 Mechanical Interlock UL 489 Mechanical Interlock UL 489 Mechanical Interlock UL 489 Mechanical Interlock M1 M1 M1 M2 M2 M2 M3 M3 M3 M4 M4 M4 Catalog number LTC21NA LTC22NA LTC23NA LTC23NB LTC24NB Product description UL486 Box lugs UL486 Box lugs UL486 Box lugs UL486 Box lugs UL486 Box lugs 1 hole 1 hole 1 hole 2 holes 2 holes 2013 NOARK Electric • All Rights Reserved C used on M1 used on M2 used on M3 used on M3 used on M4 C-7 Molded Case Accessories Connection Diagrams UVT21N SHT21N N’/- 92 91 L/+ 14 12 OFF L/+ 94 ON N/- C2 ON/OFF C-8 L/+ C1 TRIP N/- D2 AX21N U U< D1 AL21N N’/- 11 L/+ 2013 NOARK Electric • All Rights Reserved Molded Case Accessories Dimensions Unit: in. [mm] Manual operating mechanism M1 C M2 M3 2013 NOARK Electric • All Rights Reserved C-9 Molded Case Accessories Dimensions Unit: in. [mm] Manual operating mechanism M4 Electro-control mechanism 7.50[190.4] 3.54[90] 3.19[81] 2.78[70.5] 3.46[88] 2.78[70.5] 3.46[88] 6.93[176] 3.46[88] 4.67[118.5] M1 7.87[200] M2 7.36[187] 4.13[105] C-10 3.46[88] 4.63[117.5] 3.54[90] 2013 NOARK Electric • All Rights Reserved Molded Case Accessories Dimensions Unit: in. [mm] Electro-control mechanism M3 10.31[262] 9.57[243] 5.51[140] 4.61[117] 5.51[140] 4.72[120] 6.06[154] 5.12[130] C 10.98[279] M4 10.26[260.5] 7.68[195] 2013 NOARK Electric • All Rights Reserved 5.51[140] 4.61[117] 4.72[120] 6.52[165.5] 5.12[130] C-11 NOARK Electric North America 9817 South 13th Street • Oak Creek, WI 53154 (414) 304-8189 www.NoarkUSA.com • NASales@Noark-Electric.com Note: NOARK Electric reserves the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. NOARK Electric does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. NOARK Electric reserves all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of NOARK Electric. 2013 NOARK Electric • All Rights Reserved CMCCB201301NA