Protection Circuit protection Marine C60H circuit breakers (curve C, D) DB123102 IEC/EN 60947-2 Marine approvals DNV LRS b Schneider Electric is committing to have all products Marine type approved by IACS (International Association of Classification Societies): v ABS, BV, DNV, GL, KRS, LRS, RINA, RMRoS and meet international standards requirements that are compulsory for the worldwide merchant marine market, v other classification bodies: please consult us. RMRoS RINA KRS b C60H circuit breakers are circuit breakers which combine the following functions: v circuit protection against short-circuit currents, v circuit protection against overload currents, v breaking and industrial disconnection as per standards IEC/EN 60947-2. b The presence of the green strip guarantees physical opening of the contacts and allows operations to be performed on the downstream circuit in complete safety. PB100274_SE-30 PB100273_SE-30 ABS BV GL C60H 2P PB100506_SE-30 PB100505_SE-30 C60H 1P b v v v b Increased product service life thanks: overvoltage resistance, high performance limitation, to fast closing independent of the speed of actuation of the toggle. Upstream or downstream connection. Positive contact indication b Suitability for isolation in accordance with the IEC/EN 60947-2 standard. Alternating current (AC) 50/60 Hz C60H 3P Ultimate breaking capacity (Icu) as per IEC/EN 60947-2 Voltage (Ue) C60H 4P Ph/Ph (2P, 3P, 4P) 240 V 415 V - 440 V Ph/N (1P) - 240 V 415 V - Rating (In) 1 to 40 A 30 kA 15 kA 4 kA 10 kA iIT 1.2 x 12 In Service breaking capacity (Ics) 50 % of Icu Catalogue numbers Marine C60H circuit breaker Type 1P 2P 1 1 3 2 4 2 Rating (In) 1A 2A 3A 4A 6A 10 A 16 A 20 A 25 A 32 A 40 A Width in 9-mm modules Curve 3P Curve 4P 1 3 5 2 4 6 Curve 1 3 5 7 2 4 6 8 Curve C D C D C D C D MGN60608 MGN60609 MGN60610 MGN60611 MGN60612 MGN60613 MGN60614 MGN60615 MGN60616 MGN60617 MGN60618 2 MGN25080 MGN25081 MGN25082 MGN25083 MGN25084 MGN25085 MGN25086 MGN25087 MGN25088 MGN25089 MGN25090 MGN60621 MGN60622 MGN60623 MGN60624 MGN60625 MGN60626 MGN60627 MGN60628 MGN60629 MGN60630 MGN60631 4 MGN25108 MGN25111 MGN25112 MGN25113 MGN25114 MGN25115 MGN25117 MGN25118 MGN25119 MGN25120 MGN25121 MGN60634 MGN60635 MGN60636 MGN60637 MGN60638 MGN60639 MGN60640 MGN60641 MGN60642 MGN60643 MGN60644 6 MGN25124 MGN25125 MGN25126 MGN25127 MGN25128 MGN25129 MGN25131 MGN25132 MGN25133 MGN25134 MGN25135 MGN60647 MGN60648 MGN60649 MGN60650 MGN60651 MGN60652 MGN60653 MGN60654 MGN60655 MGN60656 MGN60657 8 MGN25138 MGN25139 MGN25140 MGN25141 MGN25142 MGN25143 MGN25145 MGN25146 MGN25147 MGN25148 MGN25149 version: 1.1 CM901012E.indd Protection Circuit protection Marine C60H circuit breakers (curve C, D) (cont.) Connection DB123103 Rating Tightening Copper cables Rigid Flexible or torque DB122945 5.5 mm PZ2 DB122946 with ferrule 14 mm 1 to 25 A 2 N.m 32 to 40 A 3.5 N.m 1 to 25 mm2 1 to 25 mm2 1.5 to 35 mm2 1.5 to 35 mm2 Technical data DB118767 According to IEC/EN 60947-2 Insulation voltage (Ui) 500 V AC Pollution degree 3 Rated impulse withstand voltage (Uimp) 6 kV Thermal tripping Nominal temperature for operation According to ambiant temperature C curve 50 °C D curve 12 In ± 20 % According to current frequency 50/60 Hz Magnetic tripping (Ii) Clip on DIN rail 35 mm. DB118772 Utilization category Compliance with See module 92515 8.5 In ± 20 % A IACS part E10 Other characteristics Degree of protection Endurance (O-F) Indifferent position of installation. Device in modular enclosure Electrical IP40 Mechanical 20,000 cycles 10,000 cycles Service temperature -30°C to +70°C Storage temperature -40°C to +80°C Power loss See module 92517 Connection Upstream or downstream Direct current (DC) curve C Ultimate breaking capacity (Icu) as per IEC/EN 60947-2 Voltage (Ue) Ph/Ph 60 V 125 V Number of poles 1P 2P 3P 4P 24 kA 25 kA 40 kA 50 kA Rating (In) 1 to 40 A 250 V Service breaking capacity (Ics) 100 % of Icu Weight (g) Circuit-breaker Type C60H 1P 120 2P 240 3P 360 4P 480 DB122577 Dimensions (mm) CM901012E.indd version: 1.1