CITY OF BELVEDERE PLANNING COMMISSION STAFF REPORT REPORT DATE: 7/8/2016 AGENDA ITEM: 3 MEETING DATE: 2/16/2016 TO: City of Belvedere Planning Commission FROM: Irene Borba, Director of Planning & Building REVIEWED BY: Emily Longfellow, Deputy City Attorney SUBJECT: Design Review and Exception to Floor Area for a Major Addition & Remodel of the Existing Residence for the property located at 2 Cliff Road RECOMMENDATION The applicant requests Design Review and Exception to Floor Area approval for a major addition and remodel of the existing residence. The applicant proposes a remodel/addition to the existing 9,106 square foot, two bedrooms three bath single..:family home. The remodel will include a new formal entry and garage off of the existing auto court. Except for the new garage and front entry addition, the majority of the remodel/addition would be within the existing envelope of the structure of the house. The applications and project narrative are included as Attachment} .and project plans are included as Attachment 6. ··· Staff recommends that the Planning Commission conduct the required public hearing and take the following actions: MOTION 1 Adopt the Resolution granting Design Review for the property located at 2 Cliff Road, (Attachment 1). MOTION2 Adopt the Resolution granting an Exception to Floor Area for the property located at 2 Cliff Road, (Attachment 2). PROPERTY SUMMARY Project Address: APN: Project Applicant: Property Owner: GP Designation: Zoning: Existing Use: 2 Cliff Road 060-201-10 Steve Wisenbaker (Wisenbaker Architects) Carlisle Properties LLC Low Density Residential SFD: 1.0 to 3.0 units/net acre R-15 Zoning District, Belvedere Island Single Family Residential Site Characteristics: The project site is a sloped 60,295 square-foot parcel within the R15 Zoning District, Belvedere Island. The property slopes downward from the street above; Belvedere Avenue. The subject property on Cliff Road (a private with a 9,106 square foot street) is developed v.: . ~(O -4ve residence built in 1951, an attached carport, and swimming pool. The property is heavily landscaped with existing mature vegetation and other site improvements. The residence affords views of the Golden Gate Bridge, Sausalito and San Francisco. Foundation • ZONING PARAMETERS ELEMENT PRESCRIBED EXISTING PROPOSED 15,000 SF 4,850 SF (maximum for lots greater than 14,700 SF) 60,296 SF No Change 9,106 SF 12,765 SF 30% (structures) 9,942 SF 10,215 SF Left Side Yard Setback 10' 14'-5" 14'-5" Right Side Yard Setback 1O' 7'-6" 34'-10" Rear Yard Setback 10' 71 '-6" 71 '-6" Front Yard Setback 10' 1'1 O" 10'5" Building Height 36' 43' 43' Parking Spaces 2 2 3 Lot Area Total Floor Area Lot Coverage PROPERTY HISTORY Records indicate that the residence was constructed in 1951. Since then, the residence has had minor site improvements. The following list provides details of these property changes in chronological order: 2 Cliff Road - Planning Commission Meeting July 19, 2016 Page 2 1972- CUP for gate and fence (privacy screen from road) approved by City Council (Resolution No. 1406) 1972 - CUP for a garage approved by City Council (Resolution No. 1420) 1986 - Design Review Exception for an outdoor elevator at rear of home 2002 - R7,lacement and new fencing, new deck and new glass railings. 2002 - 2n kitchen agreement executed 2002 - Staff Approval to replace existing dry rot railing with new 42 inch glass railing and wood railings. 2003 - Staff Approval to add new 36 inch stainless steel railing and add a new mechanical gate opener to the front gate. 2007 - Exemption from Design Review for a portable self-containing hot tub. 2010 - Exemption from Design Review for fence repair and replacement. 2012 - Design Review Exception to enclose a 21 OSF covered patio and stairs and retain existing roof to create new library. 2013 - Revocable License executed (RL No. 2013 .11) for a walkway/path and gas line connection, and an existing wood fence and landscaping in the City's right-of-way. PROJECT DESCRIPTION/ANALYSIS The applicant requests Design Review and Exception to Floor Area application approval for a major addition and remodel of the existing residence. The applicant proposes a remodel/addition to the existing 9,106 square foot, two bedroom three bath single-family residence. As noted above, the remodel will include a new formal entry and new three (3) car garage off of the existing auto court. As proposed the bulk and mass of the proposed addition/remodel as designed is mostly contained within the envelope of the existing structure; within existing covered areas and or under floor portions of the house. The new garage addition portion of the project would be built into the existing hillside, creating a low profile structure. The project is as follows: Main Level The existing attached carport will be removed and a new formal entry will be added off the existing auto court. The new entry will have a higher roof that mirrors the profile of the existing great room roof. An elevator will be added off the entry to connect all level of the house. A new three (3) car garage (1,045 SF) will be constructed, adjacent to the front entry to the north of the property. The new garage will be constructed into the hillside to minimize the mass and bulk of the structure. The existing kitchen and master bedroom will be removed and a new kitchen, breakfast area, family room will be added. The existing covered veranda at the front of the property will be enclosed to accommodate a new master suite. The last two sections/bays of the existing veranda will be removed completely along with the existing site stairs and retaining walls where a new deck off the master suite and new site stairs are proposed. Lower Level The existing library will be removed. Where the existing lower level deck is covered, a new enclosed space will follow the line of the structure to create a new study, powder room and sitting room. A new stair will also be added to access the new spa level below. A new recreation room is proposed where the existing storage room is proposed to be removed. A new bedroom wing with three (3) bedrooms and three (3) bathrooms will be added beneath the master 2 Cliff Road - Planning Commission Meeting July 19, 2016 Page 3 suite. As proposed, a new patio will be added at the end of the bedroom wing that connects with the landscaping. Spa Level A new level will be added to the existing structure; referred to as the spa level. At this new level will be a wet bar, storage room, den and bathroom. The new level will connect to a new patio and stairs that will access the existing pool and patio area. Colors and Materials The proposed colors and materials include a combination of stucco siding beige (earthtone) colors and stone (Sonoma Fieldstone). The colors and materials provide a soft, subdued appearance and are complementary to the existing home, the proposed modifications and the surrounding neighborhood, and incorporate materials and colors that minimize visual impacts and do not draw attention to themselves. The mix of colors and materials enhance the existing structure. A new roof standing seamed metal roof is proposed in a weathered copper. A color board will be provided to the Commissioners for their review and consideration at the meeting. Landscaping/Lighting With the exception of some landscaping and a eucalyptus tree to be removed in the location of the new garage the majority of the existing landscaping will be maintained. The existing landscaping is very mature and dense. The existing vegetation will however be required to meet the vegetation management plan requirements of the Tiburon Fire Protection District; as such additional vegetation may be required to be removed on the property such as the any existing bamboo or other existing prophetic plant materials. Staff would refer the Commission to the landscape plan that illustrates the additional plant material to be removed. Minimal exterior lighting is proposed. All proposed exterior light fixtures would be down lights and/or shielded and will not create glare, hazard or annoyance to neighboring property owners or to passersby. Fence/Gate The existing property line fencing is proposed to remain. A new metal auto gate at the front of the property is proposed. Second Unit The existing residence has a guest unit for which a Second Kitchen Agreement was executed in 2002. At the request of staff, the applicant has submitted an application for this guest area to be a converted to a Second Unit. The application for the 398 SF Second Unit is being reviewed and processed by staff for consistency with the Municipal Code and the requirements of the Second Unit Ordinance. As the Commission will recall, pursuant to Chapter 19.78, Second Unit permits must be ministerially granted by staff, with no further review, if the Code requirements are satisfied. The requested application for the Second Unit is not in the purview of the Commission as part of the Design Review and Floor Area Exception requests. 2 Cliff Road - Planning Commission Meeting July 19, 2016 Page4 DESIGN REVIEW Design Review Findings The Design Review findings, specified in Belvedere Municipal Code Title 20, state that all new structures and additions should be designed to avoid excessively large dwellings that are out of character with their setting or with other dwellings in the neighborhood. All buildings should be designed to relate to, and fit in, with others in the neighborhood and should not attract attention to themselves. To avoid monotony or an impression of bulk, large expanses of any one material on a single plane should be avoided. Vertical and horizontal elements should be used to add architectural variety, to break up building planes, and to avoid monotony. Landscaping will also soften and screen structures and maintain privacy. The Design Review findings, specified in the Belvedere Municipal Code, state that soft and muted colors in the earthtone and woodtone range are preferred and should predominate generally. The addition/remodel has been designed in such a way that it will fit well on the site, and will be compatible with the existing residence on the property and other residences in the neighborhood. The proposed addition/modifications would not be massive or out of scale with the site or surroundings. The proposed improvements fit in with others in the neighborhood and are not designed to draw attention to it. The topography of the lot is steep as the property slopes sharply down from the street above and the existing structure location is far below street level. Additionally, the project as designed is mostly contained within the envelope of the existing structure and or conforms to the topography of the site. The proposed addition/remodel is designed to avoid a monumental or an excessively large appearance and the design includes a mix of vertical and horizontal elements that will add architectural variety and blend nicely with the mature landscaping and other properties in the neighborhood. The, proposed colors and materials include a combination of stucco siding beige (earthtone) colors and stone (Sonoma Fieldstone). The colors and materials provide a soft, subdued appearance and are complementary to the existing home. As designed, the structure conforms to the setback, lot coverage and height requirements of the municipal code. Staff can make the required Design Review findings as provided in the attached Resolution (Attachment 1). FLOOR AREA EXCEPTION The applicant requests Planning Commission approval of a 12,765 SF (total) residence. The maximum permitted FAR in the R-15 Zoning District for lots greater than 14, 700 square feet in area, is 4,870 square feet. The lot is 60,295 SF in area which is four (4) times greater than the required minimum lot area of 15,000 SF for this zoning district. The existing home exceeds the maximum allowed floor area at 9,106 SF (4,236 SF over). The applicant is requesting to further exceed the maximum allowed floor area with an additional 3,659 SF, for a total overage of 7,895 SF. The Municipal Code defines floor area (gross) as follows: A. The sum of all enclosed or covered areas of each level of the building having a floor, measured to the exterior faces of the enclosing walls, columns or posts, but excluding the following: 1. Areas permanently open to the sky; 2. Exterior areas under roof eaves or other cantilevered overhangs; 2 Cliff Road - Planning Commission Meeting July 19, 2016 Page 5 3. Areas that are less than six (6') feet in clear height. B. Areas with ceiling heights of fifteen ( 15 ') feet or greater shall be calculated as twice the floor area of areas with ceiling heights less than fifteen (15 ') feet. For information purposes, Staff has provided the Commission with a chart that shows the floor area for other properties in the vicinity of the subject property (see Attachment 4, FAR Chart). ETFA Findings: Pursuant to Section 19.52.120(A)(l) of the B.M.C., in order to grant an Exception to Total Floor Area, the Planning Commission must make each of the following findings: a. That primary views from adjacent properties, as well as from the street, are not significantly impaired by the additional square footage; b. That there are unusual characteristics applicable to the parcel which minimize the impact of a greater floor area; c. That the proposed structure(s) are appropriate in mass, bulk, and character for the parcel, the neighborhood, and the zoning district, and meet(s) all design review criteria; and d. That the additional square footage will not substantially reduce the privacy otherwise available to residents of adjoining properties. In staff's opinion these findings can be made. Primary views from adjacent properties, as well as from the street, would not be significantly impaired by the proposed project due to the slope of the property and the placement of the existing residence on the site, and due to the design of the proposed addition/remodel. The proposed FAR is appropriate because this is an unusually large lot (60,295 SF) for the zoning district. This lot is four (4) times greater than the required minimum lot area of 15,000 SF for this zoning district. Additionally, as proposed the bulk and mass of the proposed addition/remodel as designed is mostly contained within the envelope of the existing structure. For example the majority of the additional square footage is within existing covered areas and or under the different floor levels of the house, and includes areas that are greater than 15' in height (i.e., the elevator). As designed the new garage addition portion of the project would be built into the existing hillside; thereby creating a new structure with a low profile on the site. Pursuant to the requirements of the code, the garage (1,045 SF) is included in the overall total floor area. The addition/remodel will not be visually out of place within the context of the neighborhood or the site. Staff is able to make the finding that privacy will be maintained, since the design of the addition/remodel' s is well thought out in relation to the adjacent neighbors and the surrounding neighborhood, the site and with the existing residence. Staff has provided the Commission with a draft Resolution of approval for the requested Exception to Floor Area (refer o Attachment 2). ENVIRONMENTAL DETERMINATION The project has been reviewed under the provisions of the California Environmental Quality Act (CEQA) and the CEQA Guidelines, California Code of Regulations. On July 8, 2016 the proposed project was determined to be categorically exempt from CEQA pursuant to Section 15303 New Construction or Conversion of Small Structures because the proposed project includes the construction of an addition/remodel involving negligible or no expansion of use beyond that existing. Additionally, the project is exempt from CEQA by the Common Sense Exemption, CEQA Guideline section 15061(b)(3), because it can be seen with certainty that 2 Cliff Road- Planning Commission Meeting July 19, 2016 Page 6 there is no possibility that the project would have a significant effect on the environment. City action is required by September 8, 2016 or the project may be deemed approved. CEQA provides certain exceptions where categorical exemptions may not be used. Under one such exception, a CEQA categorical exemption may not be used if the project has the potential to cause a substantial adverse effect on a CEQA Tribal Cultural Resource. Here a categorical exemption is appropriate because there is no potential that the project would cause a substantial adverse effect on any potential Tribal Cultural Resources that may, or may not, exist on the site. As mentioned above, the project is exempted from CEQA by the Common Sense Exemption. If it can be seen with certainty that a project will not have a significant effect on the environment, it is exempt from CEQA review. (CEQA Guidelines, § 15061(b)(3).) Here a categorical exemption is appropriate because there is no possibility that the project would cause a substantial adverse effect on any potential Tribal Cultural Resources that may, or may not, exist on the site. The subject property is categorized as a Low Sensitivity site for Tribal Cultural Resources. CORRESPONDENCE A copy of the public hearing notice for this item was published in The ARK newspaper and mailed to all property owners within 300 feet of the subject prope1iy. As of writing this report, staff has not received any written comments. CONCLUSION Staff determines that all of the findings can be made for the Design Review and the Exception to Floor Area. As stated in the Design Review findings, staff finds that the proposed modifications compatible with the architecture, the site and neighborhood. The bulk of the proposed addition is designed in manner so that it is contained within the envelope of the existing structure and or designed to confom1 to the slope of the prope1iy. Accordingly, staff has prepared a Resolution recommending approval of the Design Review and Floor Area Exception applications for the proposed project. RECOMMENDATION MOTION 1 Adopt the Resolution granting Design Review for the prope1iy located at 2 Cliff Road, (Attachment 1). MOTION2 Adopt the Resolution granting an Exception to Floor Area for the property located at 2 Cliff Road, (Attachment 2). ATTACHMENTS Attachment 1: Attachment 2: Attachment 3: Attachment 4: Attachment 5: Attachment 6: Attachment 7: Draft Design Review Resolution Draft Floor Area Exception Resolution Project Application & Narrative FAR Chart Correspondence Project Plans Departmental Reviews 2 Cliff Road - Planning Commission Meeting July 19, 2016 Page 7 CITY OF BELVEDERE RESOLUTION NO. 2016A RESOLUTION OF THE CITY OF BELVEDERE GRANTING DESIGN REVIEW APPROVAL FOR AN ADDITION/REMODEL LOCATED AT 2 CLIFF ROAD WHEREAS, a proper application has been submitted for Design Review pursuant to Title 20 of the Belvedere Municipal code for an addition for the subject property located at 2 Cliff Road; and WHEREAS, the project been determined to be categorically exempt from the California Environmental Quality Act (CEQA) pursuant to pursuant to Section 15301 Class 1(Nelil Construction or Conversion of Small Structures because the proposed project includes the construction of an addition/remodel involving negligible or no expansion of use beyond that existing; and WHEREAS, project is also exempted from CEQA by the Common Sense Exemption CEQA Guideline section 15061(b)(3), because it can be seen with certainty that the project will not have a significant effect on the environment; the property is fully developed with an existing residence and other site improvements and the proposed addition would be constructed in a developed area of the property, with minimal displacement or disturbance of soil. The project site is categorized as a site of Low Sensitivity for Tribal Cultural Resources, and; WHEREAS, the Planning Commission held a properly noticed hearing on July 19, 2016; and WHEREAS, the Planning Commission finds based upon the findings set forth in Exhibit A attached hereto and incorporated herein, that with the conditions listed below, the proposed project is in substantial conformance with the Design Review criteria specified in Section 20.04.110 to 20.04.120 of the Belvedere Municipal Code. NOW, THEREFORE BE IT RESOLVED that the Planning Commission of the City of Belvedere does hereby grant approval of the Design review application pursuant to Title 20 of the Belvedere Municipal Code to construct an addition and modifications to the existing residence with the following conditions: a) The prope1iy owner shall hold the City of Belvedere and its officers haimless in the event of any legal action related to or arising from the granting of this Design Review approval, shall cooperate with the City in the defense of any such action, and shall indemnify the City for any and all awards of damages and/or attorneys' fees and all associated costs that may result; counsel in any such legal action shall be selected by the City in its sole reasonable discretion. b) Construction shall conform to the drawings prepared by Steve Wisenbaker (Wisenbaker Architects), stamped received by the City of Belvedere on July 11, 2016. ATTACHMENT 1 Resolution 20162 Cliff Road July 19, 2016 Page 2 c) Construction shall be limited to the hours of 8:00 a.m. to 5:00 p.m., Monday through Friday, except in special circumstances after obtaining written permission from the City Manager. d) All requirements of the City Engineer (per memo dated June 30, 2016) shall be met including but not limited to: 1. An Encroachment Permit is required for all improvements, work activities, and staging or storage of equipment and materials within the public right of way, subject to approval of the Public Works Manager. 2. An updated Revocable License may be required for private improvements within the public right-of-way and easements. 3. A Geotechnical Investigation or geotechnical review letter is required. The geotechnical investigation/letter should address site preparation, foundation, grading and drainage recommendations. The Geotechnical Engineer of record shall review the proposed Grading & Drainage Plans for confo1mance with their recommendation prior to Building Permit issuance. 4. The project will require a detailed Grading Plan & Drainage Plan showing cut and fill earth volumes. Said plans shall incorporate, as appropriate, the MCSTOPPP Guidance for Applicants: Stonnwater Quality Manual for Development Project in Marin County. This can be found at the following website: (http://www.marincounty.org/depts/pw/divisions/mcstoppp/development/-/media/ Files/Departments/PW/mcstoppp/GuidanceforApplicantsv 2508.pdf). 5. The project requires a Site Plan showing the prope1iy line locations (referencing the survey source and mapping inf01mation), any existing easements, building setbacks, encroachments etc. 6. Topographic Survey info1mation shall be included either on the site plan or on a separate plan. The basis for determining elevations (assumed, NGVD, or NAVD) should also be clearly indicated. The surveyor's name and license number shall be included. 7. The project will require a Utility Plan (if not shown on the Site Plan) showing the existing site utilities and their alignment and locations, along with any proposed new locations or alignments for sewer, water, irrigation, gas, electrical, telephone, cable TV, etc. 8. The project will require an Erosion Control Plan incorporating, as appropriate, the MCSTOPPP Minimum Erosion/Sediment Control Measures for Small Construction Projects (http:/ /www.marincounty.org/ depts/pw /divisions/mcstoppp /development/-/me dia/Files/Departments/PW/mcstoppp/development/MECM_final_2009.pdf) Resolution 20162 Cliff Road July 19, 2016 Page 3 9. The existing 3-foot drainage easement (title exception 15) shall be investigated to determine if it is currently being utilized. If there is a benefit to the City of Belvedere or other entity an equivalent alternate easement shall be provided around the residence as may be appropriate and desirable. e) A final landscape and lighting plan shall be submitted for review and approval by planning staff and the Planning Commission Chair prior to issuance of the building pennit. All new exterior lighting shall be shielded and directed downward. Any new exterior lighting shall be reviewed and approved by planning. f) All requirements of the Fire Marshal (per memo dated July 7, 2016) shall be met including but not limited to: 1. The automatic fire sprinkler system shall be modified to properly protect the new and remodeled areas. The system design, installation and final testing shall be approved by the District Fire Prevention Officer. CFC 903.2 2. Approved smoke and carbon monoxide alarms shall be installed to provide protection to all sleeping areas. CFC 907.2.10 3. Access gates shall be operable using the fire District's "Knox" key system. CFC 503.6.2 4. The vegetation on this parcel shall comply with the requirements of the Tiburon Fire Protection District and the recommendations of Fire Safe Marin (CFC 304.1.2) 5. Access shall extend to within 150 feet of all portions of the facility and all portions of the exterior walls of the first story of the building as measured by an approved route around the exterior of the building or facility. CFC 503.1.1 6. The fire department access road (Cliff Road) shall comply with TFPD Policies, 425.3 Fire Department access, 425.5 Driveway and Road Widths, 425.9 Driveway and Roadway Turning Radius, 425.11 Driveway and Roadway Maximum slope of Grade. Inforn1ation on slope, easements, and other roadway information is required for evaluation. g) The general contractor shall submit a proposal to the City Manager, for review and approval, addressing the schedule for construction and parking locations for construction vehicles. Prior to the issuance of a building permit, the applicant shall update the Construction Management Plan to the satisfaction of the Building Official. h) Plans submitted to the Building Depaiiment for permit issuance shall be consistent with the approved Planning Commission plans. i) Design Review approvals expire eighteen (18) months from the date of approval. This Design Review approval expires on January 19, 2018. Resolution 20162 Cliff Road July 19, 2016 Page 4 j) Construction shall be completed within the Construction Time Limit established for this project. k) These Conditions of Approval shall be printed on the Building Pen11it Construction Plan set of drawings. 1) In the event unanticipated archaeological or paleontological resources are uncovered during construction, all work must be halted and an evaluation must be undertaken by a qualified archaeologist or paleontologist to identify the appropriate actions that shall be undertaken. m) These restrictions shall be binding upon any successor in interest of the prope11y. n) Prior to the issuance of a building pem1it the property owner shall demonstrate compliance with State/BAAQMD air quality requirements related to the dust generated by grading and construction. o) For any work within BCDC's (Bay Conservation & Development Commission) shoreline band jurisdiction, 100 feet inland from the edge of the Bay, which is defined by the Mean High Tide Line or the inland edge of marsh vegetation (5 feet above mean sea level) shall require a permit from BCDC prior to issuance of building permits. p) All requirements of the Marin Municipal Water District shall be met including but not limited to: 1. The landscape plan shall be reviewed by the Marin Municipal Water District (MMWD) for conformance with the District's Water Efficient Landscape Ordinance (WELO) prior to issuance of the building permit. Prior to issuance of a building permit the applicant shall demonstrate that the proposed landscape plans comply with MMWD. 2. The proposed project shall be in compliance with all indoor and outdoor requirements of District Code Title 13 - Water Conservation is a condition of water service. Indoor plumbing fixtures must meet specific efficiency requirements. 3. Should backflow protection be required, said protection shall be installed as a condition of water service. PASSED AND ADOPTED at a regular meeting of the Belvedere Planning Commission on July 19, 2016, by the following vote: AYES: NOES: ABSENT: RECUSED: Marsha Lasky, Planning Commission Chair ATTEST: _ _ _ _ _ _ _ __ Alison Foulis, City Clerk Resolution 20162 Cliff Road July 19, 2016 EXHIBIT A Page 1 DESIGN REVIEW FINDINGS The following sections are edited versions of Sections 20.04.11 Oto 20.04.120 of the Belvedere Municipal Code and the Design Review Criteria. In order for a design review application to be approved, the Planning Commission must find the project to be in substantial confonnance with these criteria. Preservation of existing site conditions. To preserve the landscape in its natural state, the removal of trees, vegetation, rock, and soil should be kept to a minimum. Projects should be designed to minimize cut and fill areas, and grade changes should be minimized and kept in harmony with the general appearance of the neighboring landscape. As proposed there will be minimal changes to the existing landscaping and to the existing site conditions, and removal of trees, vegetation, and rock are kept to a minimum. Additionally, the project as proposed as designed is mostly contained within the envelope of the existing structure and or conforms to the topography of the site, therefore, cut and fill areas, and grade changes are minimized and in hannony with the neighboring landscape. For example the majority of the additional square footage is within existing covered areas and or under the different floor levels of the house, and includes areas that are greater than 15' in height (i.e., the elevator) and the new three car garage as designed would be built into the hillside. As designed, the structure conforms to the setback, lot coverage and height requirements of the municipal code. Relationship between structures and the site. There should be a balance and harmonious relationship among the structures on the site, between the structures and the site itself, and between the structures and those on adjoining properties. All new buildings or additions constructed on sloping land should be designed to relate to the natural land-forms and step with the slope in order to minimize the building mass and bulk and to integrate the structure with the site. The proposed modifications are in keeping with the existing style, architecture and form of the residence, and are balanced and harmonious with the existing structures on the site and with adjoining propetiies. The design elements and selection of materials, which include a mix of vertical and horizontal elements and natural colors and textures, will add architectural variety and blend nicely with the mature landscaping and other properties in the neighborhood. The topography of the lot is steep as the property slopes sharply down from the street above. The existing structure location, and the proposed structure location, is far below street level. Additionally, the project as designed is mostly contained within the envelope of the existing structure and or conforms to the topography of the site. Minimizing bulk and mass. A. All new structures and additions should be designed to avoid monumental or excessively large dwellings that are out of character with their setting or with other dwellings in the neighborhood. All buildings should be designed to relate to and fit in with others in the neighborhood and not designed to draw attention to themselves. Resolution 20162 Cliff Road July 19, 2016 EXHIBIT A Page 2 The addition/remodel has been designed in such a way that it will fit well on the site, and will be compatible with the existing residence on the prope1iy and other residences in the neighborhood. The proposed addition/remodel is designed to avoid a monumental or an excessively large appearance. The proposed addition/modifications would not be massive or out of scale with the site or surroundings. The proposed improvements fit in with others in the neighborhood and are not designed to draw attention to it. The topography of the lot is steep as the property slopes sharply down from the street above. The existing structure location is far below street level. Additionally, the project as designed is mostly contained within the envelope of the existing structure and or conforms to the topography of the site. For example the majority of the additional square footage is within existing covered areas and or under the different floor levels of the house, and includes areas that are greater than 15' in height (i.e., the elevator) and the new three car garage as designed would be built into the hillside. B. To avoid monotony or an impression of bulk, large expanses of any one material on a single plane should be avoided, and large single plane retaining walls should be avoided. Vertical and horizontal elements should be used to add architectural variety, to break up building planes, and to avoid monotony. The project avoids monotony and the impression of bulk. The design includes a mix of vertical and horizontal elements that will add architectural variety and blend nicely with the mature landscaping and other properties in the neighborhood. There is no monotony or impression of bulk, or large expanse of any one material and as designed the addition/remodel provides some articulation and interest to the existing unique architectural structure. Materials and colors used. Building designs should incorporate materials and colors that minimize the structures visual impacts, that blends with the existing landforms and vegetative cover, that relate to and fit in with structures in the neighborhood, and that do not attract attention to the structures themselves. Soft and muted colors in the earthtone and woodtone ranges are preferred and generally should predominate. Trim and window colors should be compatible with and complementary to the other building colors. The building design uses materials and colors that minimize visual impacts, blends with the land, and fits well within the neighborhood. The proposed colors and materials include a combination of stucco siding beige (earthtone) colors and stone (Sonoma Fieldstone). The colors and materials provide a soft, subdued appearance and are complementary to the existing home, the proposed modifications and the surrounding neighborhood, and incorporate materials and colors that minimize visual impacts and do not draw attention to themselves. The mix of colors and materials enhance the existing structure. Resolution 20162 Cliff Road July 19, 2016 EXHIBIT A Page 3 Fences and screening. A. Fences and physical screening should be located so as to be compatible with the design of the site and structures as a whole, should conceal and screen garbage areas, mechanical equipment, and structural elements from public view, should preserve privacy between adjoining dwellings, where practical, and should not significantly block views. Not applicable as no new fences are proposed. Privacy. Building placement, and window size and placement should be selected to give consideration to the privacy of adjacent buildings. Due to the topography of the lot (downward slope from the street above) and the placement of the existing residence on the lot, and due to the design of the proposed addition/remodel privacy is not significantly impacted by the project proposal. The proposed addition/remodel as designed is mostly contained within the envelope of the existing structure. As designed the new garage addition portion of the project would be built into the existing hillside; thereby creating a new structure with a low profile on the site. As designed, the structure conforms to the setback, lot coverage and height requirements of the municipal code. Drives, parking and circulation. Walkways, driveways, curb cuts and off-street parking should be planned and designed so as to minimize interference with smooth traffic flow, to encourage separation of pedestrian from vehicular traffic, and to be as safe and convenient as is practical. They should not be out of relationship with the design of the proposed buildings and structures on the site, and should not intrude on the privacy of, or conflict with the appearance or use of neighboring properties. The subject parcel is located on a private street. There are no changes to walkways, driveways, or curb cuts. Access to the subject property is from the existing private road; the access will be maintained. As proposed and existing there is a large auto court as you enter into the property. The auto court allows for adequate turnaround and circulation onto the property. A new vehicle gate is proposed at the front of the property. As proposed a new three car garage will provide more than adequate off-site parking. As proposed the project is not be out of relationship with the design of the proposed buildings and structures on the site, and does not intrude on the privacy of, or conflict with the appearance or use of neighboring properties. Exterior lighting, skylights, and reflectivitv. Exterior lighting should not create glare, hazard, or annoyance to neighboring property owners or to passersby. Lighting should be shielded and directed downward, with location of lights coordinated with the approved landscape plan. Skylights should not have white or light opaque exterior lenses. All proposed exterior light fixtures would be down lights and/or shielded and will not create glare, hazard or annoyance to neighboring property owners or to passersby. Resolution 20162 Cliff Road July 19, 2016 EXHIBIT A Page4 Consideration of nonconformities. The proposed work shall be viewed in relationship to any nonconformities, as defined in Title 19, and where it is determined to be feasible and reasonable, consideration should be given to conditioning the approval upon the mitigation or elimination of such nonconformities. The applicant requests an Exception to Total Floor Area that would allow the residence to further exceed the maximum allowable floor area in the R-15 zoning district for the size lot (4,870 SF allowed). The current residence exceeds the maximum allowable floor area (9,106SF existing and a total of 12,765 SF proposed). As proposed addition/remodel as designed is mostly contained within the envelope of the existing structure. There are no other existing nonconformities. Therefore, it is not reasonable or feasible to mitigate or eliminate the proposed nonconformity. Landscape plans -- Purpose. A. Landscape plans should be compatible with the character of the site and surrounding developed properties. Native or natural appearing vegetation, with generally rounded, natural forms, should be placed to appear as loose, informal clusters. B. Landscape plans shall include appropriate planting to soften or screen the appearance of structures as seen from off-site locations and shall include appropriate screening for architectural elements, such as building foundations, deck supports, and retaining walls, that cannot be mitigated through architectural design. C. Landscape plans should provide privacy between properties. Choice of landscape materials should take into consideration the future impact which new planting may have in significantly obstructing views from nearby dwellings. Landscape Plans - Materials. A. Plant materials native to northern California and Marin County, and those that are drought-tolerant are encouraged. Evergreen species are encouraged for use in screen planting situations. Because of high water usage, turf areas should be minimized and narrow turn areas, such as in parking strips, should be avoided. B. Landscape plans should include a mix of fast and slow growing plant materials. Fast growing trees that have a short life span should be used only when planted with others which reach maturity at a later age. C. Landscape plans should include water conserving irrigation systems. Plant materials should be selected so that once established, much of the major site landscaping would survive solely on rainfall. Plant materials native to northern California and Marin County, and those that are drought tolerant, are encouraged. Because of high water usage, turf areas should be minimized and narrow turf areas, such as in parking strips, should be avoided. With the exception of the landscaping to be removed and a eucalyptus tree to be removed in the location of the new garage the existing landscaping will be maintained therefore the proposed project is consistent with the required finding. The existing landscaping is very mature and dense. The existing vegetation will however be required to meet the vegetation management plan requirements of the Tiburon Fire Protection District; as such additional vegetation may be required to be removed on the prope1iy such as the any existing bamboo. CITY OF BELVEDERE RESOLUTION NO. 2016A RESOLUTION OF THE PLANNING COMMISSION OF THE CITY OF BELVEDERE GRANTING AN EXCEPTION FROM SECTIONS 19.24.050, 19.52.090 AND 19.51.110 OF THE BELVEDERE MUNICIPAL CODE FOR THE PROPERTY LOCATED AT 2 CLIFF ROAD WHEREAS, a proper application has been submitted for an Exception to Total Floor Area from the zoning provisions of the Belvedere Municipal Code for an addition/remodel of an existing residence and allow a maximum floor area of 12,765 square feet where a maximum of 4,870 SF is permitted at 2 Cliff Road; and WHEREAS, the project has been determined to be exempt from the California Environmental Quality Act (CEQA), pursuant to Section 15301 Class (IA) of the CEQA Guidelines; and WHEREAS, the Planning Commission held duly noticed public hearings on the requested Floor Area Exception on July 19, 2016; and WHEREAS, the Planning Commission made each and every one of the following findings of fact, as required by section 19.52.120(A)(l) of the Belvedere Municipal Code: a. That primary views from adjacent properties, as well as from the street, are not significantly impaired by the additional square footage. Due to the topography of the lot (downward slope from the street above) and the placement of the existing residence on the downslope of the lot, and due to the design of the proposed addition/remodel, primary views from adjacent properties and the street are not significantly impaired by the additional square footage. The proposed addition/remodel as designed is mostly contained within the envelope of the existing structure. As designed the new garage addition portion of the project would be built into the existing hillside; thereby creating a new structure with a low profile on the site. As designed, the structure conforms to the setback, lot coverage and height requirements of the municipal code. b. That there are unusual characteristics applicable to the parcel which minimize the impact of a greater floor area. First, the topography of the lot is steep as the property slopes sharply down from the street above. The existing structure location is far below street level. Second, this lot is unusually large. The lot is four (4) times greater than the required minimum lot area of 15,000 SF for this zoning district; the lot is 60,295 SF in area. Finally, the project as designed is mostly contained within the envelope of the existing structure and or conforms to the topography of the site. For example the majority of the additional square footage is within existing covered areas and or under the different floor levels of the house, and includes areas that are greater than 15' in height (i.e., the elevator) and the new three car garage as designed would be built into the hillside. The above-mentioned unusual characteristics of the parcel minimize the impact of the greater floor area. ATTACHMENT2 Resolution No. 2016July19, 2016 2 Cliff Road Page - 2 - c. That the proposed structure(s) are appropriate in mass, bulk, and character for the parcel, the neighborhood, and the zoning district, and meet(s) all design review criteria. The proposed project is appropriate in mass, bulk and character for the parcel, neighborhood, and zoning district because the additional floor area is designed to be well integrated into the existing architecture and site. The new and existing materials that will be used in constructing the addition are proposed to blend into the existing residence and will add some architectural interest to the existing structure. As proposed the bulk and mass of the proposed addition/remodel as designed is mostly contained within the envelope of the existing structure. For example the majority of the additional square footage is within existing covered areas and or under the different floor levels of the house, and includes areas that are greater than 15' in height (i.e., the elevator). As designed the new garage addition portion of the project would be built into the existing hillside; thereby creating a new structure with a low profile on the site. Additionally, the project meets all Design Review criteria. d. That the additional square footage will not substantially reduce the privacy othenvise available to residents of adjoining properties. The additional square footage will not substantially reduce the privacy otherwise available to residents of adjoining properties due to the placement of the home on the downslope of the prope1iy and due to the design of the proposed addition/remodel. As designed, the proposed addition/remodel is oriented so that the proposed new square footage will not cause any substantial reduction in privacy from what currently exists to residents of adjoining properties. NOW, THEREFORE, BE IT RESOLVED that the Planning Commission of the City of Belvedere does hereby grant an Exception to Total Floor Area to allow a maximum floor area of 12,765 square feet where 4,870 square feet is permitted at 2 Cliff Road. PASSED AND ADOPTED at a regular meeting of the Belvedere Planning Commission held on July 19, 2016, by the following vote: AYES: NOES: ABSENT: RECUSED: APPROVED: Marsh a Lasky, Planning Commission Chair ~~~~~~~~~~~- Alison Foulis, City Clerk Project Address: _ _2_C_li_ff_R_o_a_d_ _ _ _ __ APPLICATION FOR DESIGN REVIEW CITY OF BELVEDERE • PLANNING COMMISSION 450 SAN RAFAEL AVE • BELVEDERE, CA 94920-2336 Pll. 415-435-3838 • FAX 415-435-0430 • WWW.CITYOFBELVEDERE.ORG MAY 1 6 2016 Date:_~_,---/_l_-_1-~-·__r._e.o__ Rec'd. by: i 2J-(-z,')- Amount: p!£ o--n ~~ Parcel No.: /ti 6VA "L;5.. r f 'i Receipt No.: 7 f'"YffYLJ::.:.J_ D D D nc·-r tl ~ 0- 2.>t-1 j0 Zone:_"-----'(_,,----------- Does this project have an active building permit? No 181 Does this project have Planning Commission approval? No 181 Address of Property: Planning Comm. Approval Design Review Exception Staff Approval Yes D Permit N o . : - - - - Yes D 2 Cliff Road, Belvedere. CA 94920 Record Owner of Prooertv: Mailing 816 East Portal Drive Address: Unit 86 Carlisle Properties LLC Daytime Phone: (206) 427-8883 Fax: _________________ ca_r_h_·s_le_p_r_o_p_er_t_ie_s@_a_t_t_.n_e_t_ _ _ __ Email: __ Blaine, WA 98230 Owner's Representative: ____S_t_e_v_e_W_is_e_n_b_a_k_er_Ar_ch_i_t_ec_t_s_ _ _ _ _ _ _ _ _ _ _ _ _ __ Mailing 300 Tamal Plaza Address: Suite # 200 - Corte Madera, CA 94925 - - - - - Daytime Phone: _ _(_41_5_)_9_34_-_1_02_0_ _ __ Fax: _________________ Email: __s_w_is_b_k_r@_p_a_c_b_ell_.n_e_t_ _ _ _ _ __ Project D e s c r i p t i o n : - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Remodel existing 9,106 sq. ft. two bedroom three and one half bath, single family residence. The Proposed single family residence of 12, 772 sq. ft. will all be contained within the existing envelope of - the house, except the new garage and entry roof. The Remodel will include a new formal entry and _ garage off the existing auto court. A new master suite will replace the existing covered veranda, with an additional three bedrooms below. Remove the library and enclose the structure at the lower - level to create a new den, study, powder room and recreation room. Add a new spa level below the - lower level. Add new stairs, and an elevator to connect all the levels. Design Review Application • Pag, ATTACHMENT 3 U:\planningmanager\Planning Forms\PLANNING FORMS· LATEST EDITION\APPLICAI IUN I-UK ur.~1v" "''-' v ''-''""~ . . -, • • ., __ _ Project Address: 2 Cliff Road ZONING PARAMETERS: Required Lot Area Existing ............... Lot Coverage Pro12osed 60,295 60,295 9,942 10,215 ........... Total Floor Area ....... 9,106 12,772 Front Yard Setback .... 15'-0" 97'-0" 46'-6" Left Sideyard Setback .... 10'-0" 14'-5" 14'-5" Right Sideyard Setback .... 10'-0" 7'-6" 34'-lo" Rear Yard Setback ..... 10'-0" 71'-6" 71'-6" Building Height Maximum ... 36'-0" 43'-0" 43'-0" Building Height Average ... 28.0' 20.9' 18.7' 2 2 3 Parking Spaces ....... (To Be Completed by Applicant) Date F i l e d : - - - - - - - - - - - - - - - - - - General Information I. Name and address of developer or project sponsor: _ _ _ _B_ru_c_e_C_a_r_h_·s_le_ _ _ _ _ _ _ _ __ 2. Address of project: 3. Name, address, and telephone number of person to be contacted concerning this project: _ _ _ _ __ 2 Cliff Road, Belvedere. CA 9~920 - - - - - - - - - - - - - - - - - Steve Wisenbaker Architects. 300 Tamal Plaza #200, Corte Madera. CA 94925. Tel: (415) 924-1020 4. Indicate number of the permit application for the project to which this form pertains: __O_n_e_ _ _ _ __ 5. List and describe any other related permits and other public approvals required for this project, including those required by city, regional, state and federal a g e n c i e s : - - - - - - - - - - - - - - - BCDC General Permit Application 6. Existing zoning district: 7. Proposed use of site (Project for which this form is filed): ___S_in_g_l_e_F_a_m_il_·Y_R_e_s1_·d_e_n_ti_a_1_·_ _ _ __ 8. Year built: Unknown --------------------- City of Belvedere. R-15 Original architect: __U_n_k_n_o_w_n_ _ _ _ _ _ _ _ _ _ _ _ _ _ __ Project Description 9. 11. Site size. _ _6_0_,_2_9_5_s_q._f_t_.- - - - - - - - - - - - - - - - - - - - - - - - - 12 7 72 Square footage. ___ _'_ _ _ s _ q _ . _ f _ t · - - - - - - - - - - - - - - - - - - - - - - - - Number of floors of construction. _ _T_h_r_ee_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ 12. Amount of off-street parking provided. ___T_h_r_ee_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ 13. Plans attached? __ Y_e_s_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ 10. Design Review Application • Page 2 of 9 • City of Belvedere U:\olanningmanager\Planning Forms\PLANNING FORMS - LA TEST EDITION\APPLICA TION FOR DESIGN REVIEW rev 1-11-1 I.doc Project Address: _ _2_c_1_if_f_R_o_a_d_ _ _ _ __ 18 months of construction 14. Propose9 scheduling. 15. Associated projects, such as required grading or staging. Staging in existing auto court. Small amount of grading. 16. Anticipated incremental development. 17. If residential, include the number of units, schedule of unit sizes, range of sale prices or rents, and type of household size expected. None ~~~------------------ One single family residence. 12, 772 sq. ft. 18. If commercial, indicate the type, whether neighborhood, city or regionally oriented, square footage of sales area, and loading facilities. 19. If the project involves a variance, condition.al use or rezoning application, state this and indicate clearly why the application is required. - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Are the following items applicable to the project or its effects? Discuss below all items checked yes (attach additional sheets as necessary). Change in existing features of any bays, tidelands, beaches, 9r hills, or substantial alteration of ground contours. Change in scenic views or vistas from existing residential areas or public lands or roads. Change in pattern, scale or character of general area of project. Significant amounts of solid waste or litter. Change in dust, ash, smoke, fumes or odors in vicinity. Change in ocean, bay, lake, stream or ground water quality or quantity, or alteration of existing drainage patterns. Substantial change in existing noise or vibration levels in the vicinity. (Existing) Site on filled land or on slope of 10 percent or more. Use of, or disposal of potentially hazardous materials, such as toxic substances, flammables or explosives. Substantial change in demand for municipal services (police, fire, water, sewage, etc.). Substantially increase fossil fuel consumption (electricity, oil, natural gas, etc.). Relationship to a larger project or series of projects. Changes to a structure or landscape with architectural or historical value. Changes to a site with archeological or cultural value such as midden soil. 20. 21. 22. 23. 24. 25. 26. 27. 28. 29. 30. 31. 32. 33. Yes No 0 8 ~ 0 0 0 0 0 18' J8 IS' IR 0 li1 0 0 0 0 0 0 i!1 0 ts ~ 8 11( ~ 8 Environmental Setting 34. Describe the project site as it exists before the project, including information on topography, soil stability, plants and animals, and any cultural, historical or scenic aspects. Describe any existing structures on the site, and the use of the structures. Attach photographs of the site. Snapshots or Polaroid photos will be accepted. -----------------------------------~ _ A 9,106 sq. ft. single family residence on a steep slope occupies the site. The existing pool and - 35. landscaping will remain. No animals will be disturbed more than through typical construction. There are no cultural and historical aspects of the site. Describe the surrounding properties, including information on plants and animals and any cultural, historical or scenic aspects. Indicate the type of land use (residential, commercial, etc.), intensity of land use (onefamily, apartment houses, shops, department stores, etc.), and scale of development (height, frontage, setback, rear yard, etc.). Attach photographs of the vicinity. Snapshots or Polaroid photos will be accepted. Single family residential Design Review Application• Page 3 of9 •City of Belvedere U:\olanningmanager\Planning Fonns\PLANNING FORMS - LA TEST EDITION\APPLICA TION FOR DESIGN REVIEW rev I- I I- I I .doc Project Address: _ _2_C_li_ff_R_o_a_d_ _ _ _ __ For Design Review applications not requiring a building permit this form does not apply. Review approvals expire twelve (12) months from the date of approval. Design This Section advises you of the Time Limit Guidelines that are applied to all Design Review applications that require a building permit as prescribed by Section 20.04.035 of the Belvedere Municipal Code. "As part of any application for Design Review, the applicant shall file a reasonable estimate of the cost of the proposed construction, and based thereon, a construction time limit shall be established for the project in accordance with Section 20.04.035(b) of the Belvedere Municipal Code. Compliance with such time limit shall become a condition of design review approval." The maximum time for completion of construction shall not exceed six months for additions and remodeling up to $100,000 in value; 12 months for construction up to $500,000 in value; and 18 months for construction valued at more than $500,000. Failure to complete construction in the agreed upon time will result in fines ranging from $400 per day to $800 per day with a $200,000 maximum penalty. Application for an extension of the prescribed time limit can be made providing certain conditions are met. The maximum extension is 6 months. The time for completion of the construction shall also be indicated on the building permit. In the space provided below please indicate the estimated project valuation. Estimated cost of construction:$ 4,000,000 ------------------~ Based on the above estimated project valuation, check one of the following Time Limit Guidelines that shall apply to your project: 0 1. For new construction, the demonstrable value of which is estimated to be less than $500.000. Construction shall be completed twelve (12) months from the commencement of work following the issuance of the building permit. 0 2. For new construction, the demonstrable value of which is estimated to be more than $500,000. Construction shall be completed eighteen (18) months from the commencement of work following the issuance of the building permit. 0 3. For additions, alterations, modifications and repairs, the demonstrable value of which is estimated at less than $100.000. Construction shall be completed six (6) months from the commencement of work following the issuance of the building permit. 0 4. For additions, alterations, modifications and repairs, the demonstrable value of which is estimated at less than $500,000. Construction shall be completed twelve (12) months from the commencement of work following the issuance of the building permit. ti!\ 5. For additions, alterations, modifications and repairs, the demonstrable value of which is estimated at more than $500. 000. Construction shall be completed eighteen (18) months from the commencement of work following the issuance of the building permit. For those projects that do not fall under any of the above Time Limit Guidelines or wish to exceed the time limit that was approved by the Planning Commission, the following outlines the "Extension of Construction Time Limit" (20.04.0350) process: Design Review Application• Page 4 of9 •City of Belvedere l l·lnl~nninPmnnaQer\Planning Forms\PLANNING FORMS - LA TEST EDITION\APPLICATION FOR DESIGN REVIEWrevl-11- I 1.doc Project Address: 2 Cliff Road 1. Within twelve months following the original approval of Design Review for the construction, and provided that no construction activity has yet commenced on the project, the applicant may apply for an extension of the established construction time limit, not to exceed an additional six months. 2. An application for an extension of the construction time limit shall be accompanied by complete working drawings for the construction, a written explanation of the reasons for the requested extension, and a fee, as established by City Council resolution. 3. Within 10 working days of receipt of a complete application for extension, said application shall be reviewed by a committee consisting of the City's Building Official, the City Planner, and the City Engineer, meeting together with the project contractor, architect, and, at the applicant's option, the applicant and/or any other representatives of the applicant. At the completion of such review, the committee shall make a recommendation to the Planning Commission whether to approve the requested extension. 4. The committee's recommendation shall be placed on the next available Planning Commission agenda and noticed as an amendment to the applicant's existing Design Review approval. Any modification by the Planning Commission of the original construction time limit shall not extend the existing expiration date of ' the Design Review approval. 5. Administrative extension. Within 10 working days of receipt of a complete application for extension, said application shall be reviewed by a committee consisting of the City's Building Official, the City Planner, and the City Engineer, meeting together with the project contractor, architect, and, at the applicant's option, the applicant and/or any other representatives of the applicant. The committee may recommend to the Planning Commission, and the Planning Commission may approve, an extension if it is determined that any one or more of the following factors presents an unusual obstacle to complying with the standard construction time limit: a. Site topography; b. Site access; c. Geologic issues; d. Neighborhood considerations; e. Other unusual factors. At the completion of such review, the committee shall make a written recommendation to the Planning Commission whether or not to approve the requested extension and setting forth the findings it has made justifying its decision. The Committee shall have the authority to administratively approve requests for extension, subject solely to the guidelines of Paragraphs 2 and 3 above, provided however that such extensions do not result in a construction time line exceeding 18 months. This Section advises you of the costs that may be involved in processing Planning-related applications and/or appeals. You are hereby requested to acknowledge this information and agree to be responsible for all expenses incurred in the processing of your application(s)/appeal(s). As the property owner/appellant, you agree to be responsible for the payment of all costs, both direct and indirect, associated with the processing of the applications(s)/appeals(s) referenced below. Such costs may be incurred from the following source: Hourly billing costs as of July 1, 2008, (subject to change without notice): Planning Manager $ 67.07 Assistant Planner $ 39.29 $ 185.00 City Attorney Specialized Planning Consultant Actual costs + 25% overhead Design Review Application • Page 5 of 9 • City of Belvedere l J·\nl;mnin12manager\Planning Forms\PLANNING FORMS - LATEST EDITION\APPLICATION FOR DESIGN REVIEWrevl-1 I- I I.doc Project Address: 2 Cliff Road For all appliq:itions and appeals, an initial deposit is required at the time of submittal, with the amounts determined by City Council resolution. In addition to the initial deposit, the property owner/appellant may be required to make further deposits for anticipated work. Invoices are due and payable within 15 days. Application(s) /or appeal(s) will not be placed on an agenda until these deposits are received. This Section applies to all projects that receive design review. It has been found that there are often misunderstandings regarding changes to building plans that receive Design Review. This occurs when construction plans are submitted to the Building Department for permit issuance after planning approval has been achieved. Another common occurrence is a change to the project while it is underway without first obtaining an approval from the City for the deviation from the original plan. To help your project proceed in an expeditious and harmonious manner, the City of Belvedere wishes to inform you of several basic understandings regarding your project and its approval. By you and your representative signing this document, you are acknowledging that you have read, understand, and will comply with each of the points listed. 1. Once Design Review approval has been granted, construction plans may be submitted to the City. The construction plans shall be identical to the plans approved for design review. (Authority: Belvedere Municipal Code Section 20.04.010). Deviations from the plans approved for Design Review cannot be approved except by an amendment to the Design Review approval. It is the applicants' responsibility to assure conformance, and the failure of staff to bring nonconformities to the applicants' attention shall not excuse the applicant from such compliance. 2. Comments from City staff regarding the project shall neither be deemed official nor relied upon unless they are in writing and signed by the City Manager or his designee. 3. Without the prior written approval of the City, construction on the project shall not deviate in any manner, including but not limited to form, size or color, from approved construction plans. If at any time during construction, and without such written approval, construction on the project is found by a member of City staff to deviate from the approved construction plans in any manner, an official STOP WORK ORDER will be issued by the City, and there shall be a total cessation of all work on the project. 4. If such a STOP WORK ORDER is issued, the City may initiate proceedings to impose administrative penalties or nuisance abatement proceedings and issue an order to show cause, which will compel the undersigned property owner to appear before the City Council and show cause why the work performed does not deviate from the approved plans and why such work should not be condemned as a public nuisance and abated. (Authority: Belvedere Municipal Code Chapters 1.14 and 8.12) Design Review Application• Page 6 of9 •City of Belvedere I l·\nlannim1manaeer\Planning FormslPLANNING FORMS - LATEST EDITIONIAPPLICATJON FOR DESIGN REVlEWrev 1-11-11 doc Project Address: 2 Cliff Road Story Pole Requirement Preliminary Story Poles sufficient to indicate the height and shape of the proposed structure or additions shall be placed on the site at least. twenty (20) days prior lo the first meeting date at which this application will be heard. Final Story Poles must be placed al the site at least ten (10) d,ays prior to the first meeting date and removed no later than ten (10) days following the final city action on the project application. Story poles shall be connected at their lops with colored tape or ribbon to clearly indicate ridges, eaves, and other major elements of the structure. Limit on the Number of Administrative and Planning Commi~sion Design Review Approvals Pursuant to Belvedere Municipal Code Section 20.04.020(8)(1)(a}, for a site or structure with no existing active Design Review approval, during any twelve-month period, an applicant may obtain up to four administrative approvals, which may be in the fonn of either Staff Approval, Design Review Exception, or a combination of the two. However, there is no limit to the number of times an applicant may apply for Planning Commission Design Review. Any such administrative or Planning Commission Design Review approval(s) shall be valid for a period of twelve (12) months from the date of approval, unless a building pennit has been issued for the project within said twelve (12) month period, in which case the Design Review approval shall be valid as long as there is an active building permit for the project. Once a project has been approved by Planning Staff or the Planning Commission, administrative approvals to amend the existing active Design Review approval for that project shall be limited to three such approvals at any time during the lifetime of the underlying Design Review approval, plus one such approval during the process of obtaining final inspection approval of the projecl Any such administrative approval(s) granted shall NOT extend the twelve (12) month term, of the underlying Design Review approval, or the building permit construction time limit if a building permit has been Issued for the project All property owners must complete and sign the section below which is applicable to your property. 1__c,,_~_l.f_f-__.@ ___·W . . .P.....____________ {o-Wf-lO - - - - - - - - - - - Assessor's Parcel No(s). or subject property: _...,!£'------''----"--Street address of subject property: _ _ ~ Properties Owned by a Trust, LLC, Corporation, Partnership, or Other Entity Please provide proof of ownership and of the signer's authority to enter into contracts regarding this property. One of (or a combination of) the following documents may contain the necessary infonnation. For trusts: the trust document or a certificate of trust. including any attachments thereto; property deed; certificate of title insurance. For other entities: articles of incorporation: partnership agreement; property deed; certificate of title insurance; written certification of facts by an attorney. Photocopies are acceptable. To ensure privacy, documentation will be shredded in a timely manner, or, upon request. returned to the applicant. Design Review Application ·Page 7 of 9 •City of Belvedere ""---=-· i:-nnnc\PLllNNING FORMS • L/I TEST E!JITIONIAPPLICA TION FOR DESIGN REVIEWrcv l-11-1 l doc Project Address: . .__.,,,.; ~~~~~~~~~~ -~ ~ 2(;~ . I, /3_.c:...c..e.,,.{,krr ..- {.?i:..r:;.. slate under penalty of perjury under the laws of the stale of California that the above-described subject property is owned by a trust, LLC, corporation, partnership, or other entity end that my signature on this application has been authorized by all necessary action required by the LLC, corporation, partnership, or other entlty. I hereby make application for approval of thra design review requested. I have read this application and hereby certify that the statements furnished above and In the attached exhibits present lhe date and Information required for the design review and initial environmental evaluation to the best of my ablllty, and that the facts, statements and Information presented are true and correct to the beet of my knowledge and belief I agree to be responslble for all costs lncuned In connecUon with the processing of my spp!Jcation end appeals, If any. And I agree to be bound by Section 5, •Acknowledgement of Responsibilities,• above and representations one through four contain~ thereln. In the case of an application for revocable license, I agree that, ,upon approval by the City Council or lhe revoaable license requested, I wlll promptly execute a Ocense drafted by the City, have It notarized, and return It to the City so that It may be recorded. Signed thls . Slgnstu~ Title(s) d~ of MN?t-? 7 201k, at Belvedere, Califomla. {<L 1'... . __ [.pf<,tf'..::(~gnature_ _ _ _ _ _ _ _ __ 17 /JS . . C2'NIJ r:;R O Truatee(s) 0 Partners: 0 United or 0 General Name of trust, LLC. corporaUon, or other enUty: > I Tltle(s)_ _ _ _ _ _ _ _ _ __ J D Other _ _ _ __ C~<f£~e'4ttt-i·z L.L. C:. Corpo~~.. Propertru Qwned bv lndlvldpala , state under penalty of perjury under the laws of the Stale of Callfomla that I am the record owner of the above-described subject property. I hereby make sppllcation for approval of the design review requested. I have read this application and hereby certify that the statements furnished above and In the attaehed exhibits present the data and Information required for the design review and Initial environmental evaluation to the best of my ebUHy, and that the facts, statements end infonnatlon presented am true end correct to the best of my knowledge and belief • I at1ree to be responsible for all costs incuned In connection with the processing of my eppllcalion and appeals, If any. And I agree to be·.bound by Section 5, •Acknowledgement of ResponslbllttJes,• above and representations one through rour contained therein. In the case of an application for revocable ncense, I agree that, upon approval by the City Council of the revocable Ucense requested, I will promptly executes Dcenae drafted by the Ctty, have it notarized, and return tt to the City so that n may be recorded. Signed this _ _ _ day of _ _ _ ___, 20__, at Belvedere, Callfomla. Design Review Application •Page 8of9 •City of Belvedere U:lpl~q fonnJIP1.ANNING FORMS-U.lEST EDITlON\APPUCATiON FOR DESIGN R.EVJSWmol-IM 1• Project Address: }' Designation of Owner's Representative {Optional) /3-c~.eAk:.r=_.[?L~-~26~ 2 Cliff Road ~~~-----,-~~~~~~~~ -1(~/B:- \Jl':z~/~~ 1, . hereby authorize to file on my behalf any applications, plans, papers, data, or documents necessary to obtain a'pprovals required to complete my project and further authorize said person to appear on my behalf before the Planning Commission and/or City Council. This designation is valid until the project covered by the application(s) is completed and finaled or until the designation is rescinded in writing. .::>-c...c..eAk:._ --b~~~ 26_:_ Signature of Owner: Date: Mir RC H 17, Dal~ i~t Zc/k Design Review Application• Page 9 of9 •City of Belvedere -'----------.101° 0 0 ;nn ennn<IPI ANNING 2,D( b FORMS- LATEST EDITION\APPLICATION FOR DESIGN REVIEWrevI-I I-I I.doc Project Address: __ 2 Cliff Roa_d_ _ _ _ _ _ __ APPLICATION FOR EXCEPTION TO TOT AL FLOOR AREA CITY OF BELVEDERE • PLANNING COMMISSION ,. - 450 SAN RAFAEL AVE • BELVEDERE, CA 94920-2336 PH. 415-435-3838 • FAX 415-435-0430 • WWW.CITYOFBELVEDERE.ORG Date: Rec'd. by: Assessors Parcel No: f) "46. '-c) -'1..b I-{'> Address of Property: 2 Cliff Road, Belvedere. CA 94920 Type of Property: Single Family Residential Reco~Own&~Property: _ _ _ _c_u_li_·s_~_P_ro_p_e_r_ti_e_s_L_L_c_ _ _ _ _ _ _ _ _ _ _ _ _ _ _~ Mailing 816 East Portal Drive Daytime Phone: _ _(2_0_6_)_4_27_-_88_8_3_ _ _ __ Address: Unit 86 Fax: _ _ _ _~-----------~ Email: ___ca_r_l_is_le_p_r_o_pe_r_t_ie_s_@_a_tt_.n_e_t_ _ _ _ __ Blaine, WA 98230 Owner's Representative: _ _ _S_t_e_ve_W_i_se_n_b_a_k_e_r_Ar_ch_1_·t_ec_t_s_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ __ Mailing Address: Daytime Phone: _ _(4_1_5_)_9_34_-_1_02_0_ _ _ __ 300 Tamal Plaza Fax: _ Suite # 200 - swisbkr@pacbell.net Corte Madera, CA 94925 ORDINANCE REQUIRES: 4,35 o ~---------------~ sq. ft. YOUR APPLICATION HAS: 12,772 _sq. ft. As provided in Belvedere Municipal Code Section 19.52.120(1), I hereby apply for an exception to the floor area requirements in the Zoning Ordinance. I propose that the Planning Commission make the following findings of fact: 1. That primary views from adjacent properties, as well as from the street, are not significantly impaired by the additional square footage, because: - - - - - - - - - - - - - - - - - All of the new improvements are within the existing envelope of the building, except the new garage and entry roof. The existing landscaping that is to remain will screen the proposed improvements from the view of the neighbors and the street. Exception to Total Floor Area Application • Page I of 3 • City of ?elvedere 11·\olannin~manager\Plannin~ Fom1s\PLANNING FORMS • LA TEST EDITION\APPLIC ATION FOR EXCEPTION TO TOT AL FLOOR AREA.doc Rev. 9123/2008 LC , ,, Project Address: ____ 2 Cliff R_o_a_d_ _ _ _ _ _ __ 2. That there are unusual characteristics applicable to the parcel which minimize the impact of a greater floor area, because: - - - - - - - - - - - - - - - - - - - - - - - - - - - The existing building does not have a garage, and has a large footprint in an unusual configuration. The current floor plan does not optimize the space. By utilizing the floor area within the footprint we are able to optimize the location of all the program within the house. 3. That the proposed structure(s} are appropriate in mass, bulk, and character for the parcel, the neighborhood, and the zoning district, and meet(s} all Design Review criteria, because: _ _ _ __ The mass and bulk of the proposed structure is very similar to the existing building. The only elements not within the existing envelope of the house are the garage and entry roof. These are consistent with the neighborhood because local residences have a garage and a formal entry, which the existing building does not have. 4. That the additional square-footage will not substantially reduce the privacy otherwise available to residents of adjoining properties, b e c a u s e : - - - - - - - - - - - - - - - - - - - - All proposed occupiable spaces are,in, or below existing occupiable spaces. Therefore, we are proposing no new angles or views into the neighboring properties that do not currently exist. In addition, Section 19.52.120(2} includes guidelines that the Planning Commission must follow. propose that the following guidelines can be met: 5. That the proposed new construction would not create a new or expand on existing nonconformity ontheproperty,because: ____________________________ The proposed project removes the structures within the right side setback. The maximum building height does not increase. The average building height of the proposed house is lower than the existing residence. Exception to Total Floor Area Application • Page 2 of 3 • City of !3elvedere 11-1n1onninom•n""'''\Plonnino Fonns\PLANNING FORMS. LATEST EDITIONIAPPLICA TION FOR EXCEPTION TO TOTAL FLOOR AREA doc Rev ?IZ2J2008 LC Project Address: 2 Cliff Road (For purposes of this Section, floor area in the existing structure which is in excess of the requirements of this chapter shall not be considered to be an "existing nonconformity" on the property, and the grant of a floor area exception hereunder shall not be deemed to create a "new nonconformity." Additionally, for purposes of this section, where an applicant proposes to construct new and additional parking spaces, construction of parking structure or spaces within a setback shall not be deemed to create a nonconformity.) 6. That the proposed new construction is not a continuation, expansion, or subsequent phase of a project for which one or more variances were granted, which project was completed within two years prior to the floor area exception application, because: - - - - - - - - - - - - - - No projects have taken place at this property for over two years. I, the undersigned owner of the property herein described (or owner representative, as authorized by completion of a Statement of Ownership and Designation of Representative), hereby make application for approval of the exception as requested, and I hereby certify that the facts, statements and information presented herein and in the attached exhibit(s) are true and correct to the best of my knowledge and belief Signature: Name: Date: s:<3zztc./ ~ ~~ wl~J?A(g:A~ MA'f<Ctt 11, 1.v'lk Exception to Total Floor Area Application • Page 3 of 3 • City of f?elvedere 11 lnhnn;nonrnn•un\Plmm;nu FnnmlPI ANN!Nn FORMS -1 ATFST FDITIONIAPPLICATION FOR EXCEPTION TO TOTAL FLOOR AREA.doc Rev 9f2.lf2008 LC 682-WP SERIES EXTERIOR WALL DESCRIPTION 682-WP "Floating" Wedge Wall Sconce features bronze construction and is available in two sizes. Date SPECIFICATION FEATURES Material Painted aluminum or solid bronze. 1/8" white acrylic diffuser for CFU Incandescent and clear tempered refractive glass for MH. Optional clear tempered glass for full cut-off. Finish Premium TGIC polyester powder coat paint, 2.5 mil nominal thickness for superior protection against fade and wear. Standard: Natural Bronze (NBZ) [Sustainable Design]. Note: Bronze will weather to a dark bronze patina. Premium: Aluminum Paint (ALP), Black Paint (BK), Bronze Metallic Paint (BM), Dark Platinum Paint (DP), Gold Metallic Paint (GM), Graphite Metallic Paint (GRM), Grey Paint (GY), Verdigris (VG), White Paint (WH) or Custom Color (CC). Optics Refer to www.shaperlighting.com for complete photometrics. Ballast Integral electronic HPF multi-volt 120/277V (347V Canada), thermally protected with end-of-life circuitry to accommodate 26W, 32W or 42W lamps. Metal halide ballasts are HPF open core & coil type, multivolt 120/277V for the specified lamp wattage. Contact the factory for347V. Installation Supplied with a mounting back for a standard 4" J-box or stucco ring. Optional rear (through wall) feed conduit mounting. Surface mount conduit power feed - Contact factory. Lamp/Socket 8": One (1) or two (2) 26W or 32W (GX24q-3) triple CFL lamp(s), one (1) 42W (GX24q-4) triple CFL lamp, or one (1) 75W A-19 lamp. 11 ":Two (2) 26W, 32W (GX24q-3) or 42W (GX24q-4) triple CFL lamps, one (1) SOW, 70W or 100W ED-17 Metal halide lamp or one (1) 100W A-19 lamp. CFL socket injection molded plastic. INC socket fired ceramic rated for 660W-250V. MH socket ceramic pulse-rated, 4KV. INC socket fired ceramic rated for 660W/250V. Lamps furnished by others. Options Rear (through wall) Feed Conduit Mounting (C), Blunt Nose (BN), Photocell with 1 1/2" deep back support (PH), Quartz Restrike - MH 11" only (QR), Clear Tempered Glass Lense for full cut-off (TGL) [Dark Sky Compliant]. Labels U.L. and C.U.L. listed for wet location. Modifications Shaper's skilled craftspeople with their depth of experience offer the designer the flexibility to modify standard exterior wall luminaires for project specific solutions. Contact the factory regarding scale options, unique finishes, mounting, additional materials/colors, or decorative detailing. LED 8" L0:1000 nominal luments at max 15.SW Long-life LED system coupled with electrical driver to deliver optimal performance. Electronic drivers are available for 120-277 applications. The standard driver is ELV reverse phase dimmable. Type IV-Forward throw optic is standard. a· 11" Mounting Type WP= Exterior Wall Lamp 1 CFLJ1(26132/42W-Triple) 1 CFLJ2(26132/W-Triple) CFLJ2(26132/W) 2 INC11ns• 2 INC/1/100 MH/115a2 MH11no 2 2 MH/1/100 LED L0/827 ~ L0/830 1 L0/840 Voltage 120V 3 277V 4 347V Finish 5• 8 ~ NBZ=Natural Bronze Premium ALP= Aluminum Paint BK= Black BM = Bronze Metallic Paint LED UNV (120-277V) CC= Custom Color DP= Dark Platinum Paint GM= Gold Metallic Paint GRM = Graphite Metallic Paint GV=Grey VG= Verdigris Notes: 1 Avellable In a• only. 2 Availablein11"only. 3 CFL and MH only. 4 Available with CFL only. TGIC polyuter pawder coat paint. 2.5 mil nominal thickness for superior protection against fade and wear. 8 Bronze will weather to a dark bronze patina. 7 MHonly. 8 For CFL and INC lamping (TGL is standard with MH lamping). LEDi.amp L0..1000 nominal Ium ens at max 155W & Premium Cooper Lighting by lf.:.'r•N ~~~-~~-·-1 Shaper Lighting certifies that its produc~s' satisfy the requirements of Section 1605 of the American Recovery and Reinvestment Act {also known as the ARRA Buy American provision). ~SKY Sample Number: 682-11-WP-MH/1nll-277V-VG-BN Size Exterior Wall Luminaire "Floating" Wedge V'iil DARK ORDERING INFORMATION Series 682 =Floating Wedge Wall Sconce 682-WP SERIES WH=White Options BN=Blunt Nose C= Rear (through wall) Feed Conduit Mounting PH =Photocell 2 7 QR=Quartz Restrike ' TGL=Clear Tempered Glass Lens• Shaper offers a selection of exterior lumi· naires that are "'Dark Sky Compliant". The IESNA (Illuminating Engineering Society of North America) defines Full Cut-Off as fixtures with light distributions of 0% candela at 90" and 10% at 80". Full Cut-Off luminaires carry the endorsement of the International Dark-Sky Association (IOA) for their effectiveness in limiting the detrimental effects of sky glow, also referred to as "'Light Pollution•. Many exterior luminaires offer a clear, tempered glass option that meets the IES criteria for Full Cut-Off. QUICK SHIP (OS) Shaper's Quick Ship program features over thirty-four fixtures with finishoptions such as Satin Chrome, Natural Aluminum and Satin Brass, and a wide variety of lamp selections. AU products ship in five days from receipt of order, f.lii\ 'V SUSTAINABLE DESIGN Ishaper has a long--standing history of offering environmentally·frlendly fixtures. The copper and bronze alloys used in our exterior luminaires feature up to 98% recycled conten1, con1ribute less undesirable air emissions compared to painted aluminum and are easy to recycle. ADS042807 2014-05-20 08:26:06 682-WP SERIES EXTERIOR WALL DIMENSIONS 12" (30.5 cm) 8-1/2" (21.6 cm) 8" (20.3 cm) I 1 1· 1-3/8" (3.5 cm) 2" 11" (27.9 cm) (5.1 cm) ·1 --i--i-1- •1 1ni",mID ,. ,,,r=[~ 10" 10" [ (25.4cm) 6" [ (15.2 cm) '-------~ 11" I· 8" 1· ·1 DJ·· ·I b]J· I 682-WP-r STANDARD I 682-WP-11" STANDARD STANDARD OPTIONS 7-1/2" (19 cm) PHOTOCELL (PH) BLUNT NOSE (BN) COMPANION PRODUCTS 687 684-WP 687-WP Eaton Cooper Lighting by E:.Y•N 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com 982-PT Eaton's Cooper Ughtlng Busin1121 Highway 74 Sooth Peachtree City, GA 30269 P: 77().486-4800 www.cooperlighting.com 982-W Specifications and dimensions S1.1bject to change without notice. ADS042807 2014-05-20 08:26:06 N!if££ Type Project Catalog No. Lamp/Wattage SAPPHIRE Series 611 LED High-Lumen Downlight The Saphire Series by NSpec is an architectural grade LEO high lumen downlight available in 4", 6 11, and 8 11 apertures. The Sapphire Series features deep cone reflectors and dimmable LEDs. Cree LEDs and Cree LEO Drivers make for a solid, complete, fully tested package. The reflectors have been designed by Nspec for the high efficiency (LPW) while providing low aperture brightness. The NSpec Commercial and Architectural Sapphire Series is proudly assembled in the USA. COMMERCIAL FRAME REFLECTOR NCH-630 Series j NC-631 Series CONSTRUCTION ~ Frames require a minimum clearance of 3" ring from thermal insulation and 1/2" from adjacent building component Mln!!!!!!!g Two 13-5/8" to 24-1/2" adjustable bar hangers with captive nails, alligment foot and T-Bar Slot are included on frame. Bar hangers are parallel to junction box, but can be repositioned 90° perpendicular to junction box if desired. L-shaped bar hanger foot aligns to bottom of construction joist At-Bar notch allows for easy installation in a suspended ceiling. Junction Box Plaster frame integrated 29 cubic inch 0.064" thick galvanized steel, with seven 112" knockouts, four pryouts, and snap on cover. Electrical connections are made through a single junction box door. Green wire provided for installations with ground wire fed through PVC pipe conduit. Jhermal Protector External thermal device is located on the junction box wrap. Driver: • 850 Lumen - 11 Watts • 1250 Lumen - 16 Watts • 2000 Lumen - 25 Watts · 3000 Lumens - 36Watts • 4000 Lumens - 43Watts Triac Dimming Triac Dimming 0-10V Dimming 0-10V Dimming 0-10V Dimming Model Number Lutron Nova T NTFTV/NFTV Lutron Diva DVIV Leviton lllumatech IP710-DLZ Labels and Listings cULus Listed for Wet Location when used with compatible housing Warranty: 10 Year Limited Warranty Trtm OD: 7-112" Aperture: 6" Height 6-114" FEATURES Reflector Deep cone self flanged reflector spun from 0.050 high grade aluminum provides even illumination and visual comfort The deep cone reflectors provide 55+ degree cut-off. The reflector includes the LED optical package and heat sink mounted to the top. NC-638 includes 3 stud mounted in flange for attaching decorative glass. Reflector Assembly Reflector easily wires to dedicated frame with locking quick connect. l&!!m NC-631 Series CREE LED Module Compatible Housings Reflector is only compatible with cULus listed for use with respective Sapphire Series frame manufactured by Nora Lighting. ~ ·Cree True White® Technology • Flat frosted shatterproof acrylic composite lens ·90+CRI • 97 LPW LEDs producing high efficiency fixture performance • LM-80 data ·Dimmable • 60° Beam Angle Wattage:~: 10.53W=707.41m, 15.70W=11351m, 24.52W=16851m, 36.44W=25391m, 41.10W=33331m The driver is an isolated driver, the isolation separates the primary side from the secondary side. Note: Some drivers are available in Triac/0-10V. Consult factory. Tested 0-10V Dimmers NC-636 Series ~­ ~ 7"max Plaster Frame Architectural quality 0.050 galvanized steel ring riveted to elevated 0.064 steel junction box and driver tray. NC-638 Series labels and Listings cULus Listed for Wet Location when used with compatible housing Bodine Emergency Lighting Eaupment BSL17-C2/BSL17C-C2 (for 850lm and 12501m), BSL17C-C2P (for 20001m and 30001m) • Up to 7.0W emergency illumination with LEDs. • Illumination Time: 90min •Dual Input Voltage: 12012n VAC, 60Hz • Output Voltage: 15.0-50.0 VDC Comfort Dim Comfort Dim color tunes the temperature from a bright 2700K, to a romantic and comfortable 1BOOK on a gradual, even curve. Comfort Dim is available in 4 different lumen levels: • 850 and 1250 Lumens for lower ceiling heights in commercial and residential applications. (Sapphire and Marquise Series) • 2000 Lumens for light scommercial and residential high veiling applications. (Sapphire and Marquise Series) • 3000 Lumens for commercial applications (Sapphire Series) Specification Sample: NCH-63012LE1 I NC-631L1240DSF N SPEC .-...CJ\UI.,_,,... a division of Nora lighting 6505 Gayhart St., Commerce, CA 90040 www.nspeclighting.com • Specifications subject to change without notice. © 2013 Phone: 800.686.6672 • FAX: 800.500.9955 • e-mail: nora@noralighting.com Page 1 of 3 SAPPHIRE Series 611 LED High-Lumen Downlight 611 Sapphire Commercial Housing Sapphire Series NCH-630/ Driver Lumen Voltage !085=850 I lo 611 Sapphire Reflectors I Emergency Option Sapphire Series 0 NC-631 Open Reflector DLE2=277V 12= 1250 [J NC-636 Wall Wash 6 LE4 = 120/277V (Triac I 0-1 OV) ,Q20=2000 I Lumen l85 = 850 6 l 12 = 1250 CJ NC-638 Decorative Glass• i030= 3000 b40=4000 (Blank) = Standard 0 CD= Comfort Dim [J 27 = 2700K p 30=3000K Reflector Flange pB =Black po P35=3500K DHZ =Haze L30 = 3000 b 40=4000K W=White 6 CJ SF = Self Flange = Clear Diffused l20 = 2000 L40 = 4000 G Color Temp. I aM = Emergency LE1=120V 0 WSF =White Flange CD=Comfort Oim roecorative NTG glass spec1f1ed and ordered seperately Deco Glass Options D NTG-681120 6" Tempered Blue Glass with 4-314" Open Center 'LUXX: Consult factory for Lutron Driver Options 0 NTG-68180 D NTG-6CF 6" Tempered Blue Glass with 3-1/B" Open Center D NTG-6FC 6" Tempered Frosted Glass with Clear Center D NTG-6HC 6" Tempered Clear Glass with Frosted Center and 3-1/8" Open Cen1er 6" Tempered Clear Glass with Frosted Cen1er NCH-630/85LE1 I NC-631 L8530DSF (10.53W, 707 .41m, 3043K) I j Input Watts: 11W Lumens: 707.4L I CRI: 93.3 j Efficacy: 67.2L/Watt CCT:3043K PF: 0.972 SC: 1.0 COEFFICENTS OF UTILIZATION CONAL CAVITY METHOD EFFECTIVE FLOOR CAVITY REFLECTANCE =.20 cc 90 WALL 70 50 30 10 80 70 50 30 10 70 70 50 30 10 50 50 30 10 30 50 30 10 10 50 30 10 0 0 RCR 0 1 2 3 4 5 6 7 8 9 10 1.191.191.191.19 1.14 1.12 1.10 1.08 1.10 1.061.02 0.99 1.05 1.00 0.96 0.92 1.01 0.95 0.90 0.87 0.97 0.90 0.84 0.81 0.93 0.85 0.80 0.76 0.88 0.80 0.75 0.72 0.85 0.76 0.71 0.67 0.80 0.72 0.66 0.63 0.77 0.68 0.63 0.59 1.16 1.16 1.161.16 1.12 1.10 1.08 1.06 1.08 1.04 1.01 0.98 1.03 0.98 0.95 0.92 0.99 0.94 0.90 0.86 0.95 0.89 0.84 0.80 0.91 0.84 0.79 0.76 0.87 0.80 0.75 0.71 0.83 0.75 0.70 0.67 0.79 0.71 0.66 0.63 0.76 0.67 0.63 0.59 1.11 1.11 1.11 1.06 1.04 1.03 1.01 0.98 0.96 0.96 0.93 0.90 0.92 0.88 0.85 0.87 0.83 0.80 0.83 0.79 0.75 0.78 0.74 0.71 0. 74 0.70 0.67 0.70 0.66 0.62 0.67 0.62 0.59 1.06 1.06 1.02 1.01 0.98 0.96 0.94 0.91 0.90 0.86 0.85 0.82 0.82 0.78 0.77 0.73 0.73 0.69 0.69 0.65 0.66 0.62 1.02 0.99 0.95 0.92 0.88 0.84 0.80 0.76 0.72 0.69 0.65 1.00 0.95 0.91 0.86 0.82 0.77 0.73 0.69 0.65 0.61 0.57 1.22 1.22 1.171.14 1.12 1.07 1.07 1.01 1.03 0.96 0.98 0.91 0.94 0.86 0.89 0.81 0.86 0.77 0.81 0.72 0.78 0.68 1.22 1.12 1.04 0.97 0.91 0.85 0.80 0.75 0.71 0.67 0.63 1.22 1.09 1.00 0.93 0.87 0.81 0.77 0.72 0.68 0.63 0.59 INTENSITY (CANDLEPOWER) SUMMARY ANGLE MfAN CP 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 "" N!i..f'LC 657 666 671 650 607 544 449 284 114 44 13 LUMINACE SUMMARY CD./SQ.M. ANGLE MEAN CO/SQM 45 55 65 75 85 3422 341 64 0 0 1.06 1.00 0.94 0.89 0.84 0.79 0. 75 0.70 0.66 0.62 0.58 1.02 1.02 0.98 0.97 0.94 0.92 0.89 0.88 0.85 0.83 0.81 0.78 0.77 0.74 0.73 0.70 0.69 0.66 0.65 0.62 0.61 0.58 ZONAL LUMENS & PERCENTAGES ZONE 0-30 0-40 0-60 0-90 40-90 60-90 90-180 0-180 LU MENS 493 664 707 707 43 1 0 707 %LUMINAJRE 69.66 93.94 99.92 100.00 6.06 0.08 0.00 100.0 4 1 0 0 0 0 0 c@us LISTED n a division of Nora Lighting 6505 Gayhart St., Commerce, CA 90040 www.nspeclighting.com • Specifications subject to change without notice. © 2013 Phone: 800.686.6672 • FAX: 800.500.9955 • e-mail: nora@noralighting.com Page 2 of 3 Ng:[£ Type Project Catalog No. Lamp/Wattage SAPPHIRE Series 611 LED High-Lumen Downlight 120-VAC Dimmer Compatibility for 850 and 1250 lumen Triac dimming Manufacturer Cooper Leviton Lutnm Pass and Seymour Wattstopper C N S p £.......... ~ a division of Nora Lighting Model/Series Part Number Type Compatible with 1 LMH2 Compatible with 2 LMH2s Rotary 6020 IND ./ ./ Aspire 9530 IND ./ ./ Aspire 9534WS-K-l IND/MLV Aspire 9540WS IND/MLV ./ ./ Devine Dl106P-V IND ./ ./ Devine Dl10P IND React RI061-V IND ./ ./ ./ React RI06P-LA IND ./ ./ Skye SI06P IND/MLV ./ ./ Skye SI061-V IND ./ ./ Skye Sl10P IND/MLV ./ Trace T1061-W IND ./ Trimitron 6602 IND ./ ./ ./ ./ Acenti AT106-1LW IND ./ ./ Hlumatech IPI06 IND ./ ./ ./ Vizla RP106 IND ./ ./ Ariadni AY-600P IND ./ ./ Ceana CN..SOOP IND ./ ./ ./ ./ Ceana CNLV-V-SOOP MLV ./ Centurion G-600 IND ./ ./ Decora VPIOfHLW IND ./ ./ Dial Dimmer D-600 IND ./ ./ Diva DV..SOOP IND ./ ./ Diva DV-10P IND Diva DVELV-300P av ./ ./ ./ ./ Diva DVF-103P FLR ./ ./ Diva DVLV-600P MLV ./ ./ ./ Diva DVWCL-153DH CRJl.ED ./ Glyder GL..SOOH IND/MLV ./ ./ Lumea LG-603PG IND ./ ./ Lyneo LX..SOOPL IND ./ ./ Maestro MA-1000 IND ./ ./ ./ Maestro MALV-1000 MLV ./ Maestro MAW-600 IND ./ Maestro MRF-600M IND ./ ./ Nova N-600 IND ./ ./ Nova NLV-1503P MLV ./ ./ ./ ./ ./ NovaT NTB-600 IND ./ NovaT NT-603P IND ./ NovaT NTELV-600 av ./ Skylark S-600 IND ./ ./ Skylark S-SOOP IND ./ ./ Skylark SaV-300P av ./ Skylark SLV-600P MLV ./ SUresllde 6673.P CFL ./ ./ ./ ./ Toggler TG-SOOPH IND ./ ./ Decorator LS600 IND ./ Miro MCD267-W UNI ./ ./ ./ 6505 Gayhart Sl, Commerce, CA 90040 www.nspeclighting.com • Specifications subject to change without notice. © 2013 Phone: 800.686.6672 • FAX: 800.500.9955 • e-mail: nora@noraiighting.com Page 3 of 3 RECEIVED SOLARBAN® 60 Solar Control Low-E Glass ,Ji.I! ~ 0 2016 City of Belvedere ~- ~---- --... iclea7vape7® Glass • Coatings • Paint So/arbarf' 60 solar control, low-e glass by PPG was engineered to control solar heat gain, which is essential to minimizing cooling costs. In a standard one-inch insulating glass unit (IGU), So/arbarf' 60 glass offers an exterior appearance similar to clear, uncoated glass. With a very good Solar Heat Gain Coefficient (SHGC) of 0.39, Solarban° 60 glass blocks 66 percent of the total solar energy while allowing 70 percent of the visible light to pass through. This combination produces an excellent Light to Solar Gain (LSG) ratio of 1. 79, along with exceptional insulating performance, as evidenced by its 0.29 winter nighttime U-value. Aesthetic Options Solarban° 60 glass can be coated on Starphire 0 glass and paired with Starphire 0 glass to produce an IGU with exceptional clarity and solar control characteristics. For even more color and performance options, it can be coated on the second (#2) surface of nearly all PPG's wide range of tinted glasses, or combined in an IGU with any PPG tinted glass, Solarcoo/ 0 reflective glass or Vistacoo/ 0 subtly reflective, color-enhanced glass (see performance data on back page). Solarban®60 Glass and Sustainable Design An energy modeling study conducted by an independent energy design and consulting firm showed that architects and building owners can potentially save millions of dollars during a building's lifetime by specifying Solarbarf' 60 glass instead of less advanced architectural glazings. Prudential Center Location: NeJvm·k, NJ Prodttct: Solarban 60 Glass Architect: Morris Adjmi Arcbitects Glass Contractor: ]osloff Glass Glass Fabricator: J.E. Berkowitz, LP For instance, the study showed that, by substituting Solarbarf' 60 glass in place of dual-pane tinted glass, the owners of a typical glass-walled, eight-story office building in Boston could lower their initial HVAC equipment costs by nearly $350,000 while realizing annual energy savings of more than $80,000. Corresponding carbon emissions from the same building were also reduced by more than 300 tons per year, which eclipses the total carbon emissions generated by 31,000 gallons of gasoline. In addition to making products that support sustainable design, PPG has pioneered innovative technologies that reduce energy consumption during the glass-making process. PPG promotes environmentally responsible manufacturing by recovering and reusing virtually all of its glass manufacturing by-products and by shipping its materials on reusable steel racks. PPG also facilitates regional sourcing through its nationwide network of certified glass fabricators and laminators. Streeter Place Location: Chicago, IL Product: Solarban 60 Glass Architect: Solomon Cordwell B11enz and Associates 01Pner/Denloper: Goltlb and Company Glass Fabricator: Nortlnvestem lndttstries, Inc. Glazing Contractor: C11stom Windows and ]&D Erectors With Solarbarf' 60 glass, sustainable design and LEED 0 credit opportunities are provided according to the following criteria: LEED I Green Design Category Feature Benefit Optimizing Energy Performance Daylight & Views Innovation in Design Excellent SHGC, U-value, and Tvis performance High VLT Cradle to Cradle Certification<M Enhance energy performance of building design Connectivity to natural lighting and the outdoors Selection of environmentally-focused product evaluation SOLARBAN® 60 Solar Control Low-E Glass Fabrication and Availability Solarban@ 60 glass is just one of many Ecological Solutions from PPG™. For • Solarban@ 60 glass is available • ~ PPG exclusively through the • ec:tlogical Solutions rrorn P!'O" more information, or to obtain samples of this product, call 888-PPG-IDEA (774-4332) , or visit ppgideascapes.com . Certified FABRICATOR· NETWORK PPG Certified Fabricato~ Network. PPG Certified Fabricators can meet tight construction deadlines and accelerate the delivery of replacement glass before, during and after construction. Solarban@ 60 glass is manufactured using the sputter-coating process and is available for annealed, heatstrengthened and tempered applications. www. PPG is the first U.S. float glass manufacturer to have its products recognized by the Cradle to Cradle CertifiedcM program, and it offers more C2C-certified architectural glasses than any other float glass manufacturer. PPG ldeaScapes.0 Integrated products, people and services to inspire your design and color vision. Additional Resources Solarban° 60 Glass Performance - Commercial Insulating Glass Unit Comparisons Using 1/4" (6mm) Glass 1-inch (25mm) units with 1/2-inch (13mm) airs ace and two 1/4-inch (6mm) lites; as shown below lnsulatin Vision Unit Performance Com arisons Transmittance Glass Type --,11•1r!'1;~ra 1 .ai::..1 ....., •• Ultraviolet % SOLARBAN 60 (2) STARPHIRE' SOLARBAN 60 (2) ATLANTICA + Clear SOLARBAN 60 (2) AZURIA + Clear SOLARBAN 60 (2) OPT/GRAY+ Clear I SOLARBAN 60 (2) PACIFICA + Clear SOLARBAN 60 (2) SOLAR BLUE+ Clear - I 5 10 SOLARBLUE"' + SOLARBAN 60 (3) Clear 10 SOLARBRONZE"' + SOLARBAN60 (3) Clear 8 8 10 AZURIA"' + SOLARBAN 60 (3) Clear GRAYLITE"' II+ SOLARBAN 60 (3) Clear OPT/GRAY" + SOLARBAN 60 (3) Clear SOLARGRA Y"' + SOLARBAN 60 (3) Clear SOLEXIA"' + SOLARBAN 60 (3) Clear 1rM#]ll~•m 11•1r!'1;~1r,•..S. ~STACOOL (2) AZURIA + Low-E ,,•• , ..,.,,JllJS..f1F:, • ~ii • • SOLARCOOL (2) AZURIA + Low-E SOLARCOOL (2) PACIFICA + Low-E SOLARCOOL (2) SOLARBLUE + Low-E SOLARCOOL (2) SOLARBRONZE + Low-E SOLARCOOL (2) SOLARGRAY + Low-E SOLARCOOL (2) SOLEXIA + Low-E .11 ....11 • 11 4 ISTACOOL (2) PACIFICA+ Low-E (, 10 PACIFICA"' + SOLARBAN 60 (3) Clear SOLARBAN 60 (2) SOLEXIA + Clear ATLANTICA"' + SOLARBAN 60 (3) Clear - 18 24 5 13 8 8 10 5 13 1 10 5 SOLARBAN60 (2) SOLARBRONZE +Clear SOLARBAN 60 (2) SOLARGRAY + Clear II Visible % 70 74 53 54 50 34 45 42 35 61 53 54 7 50 34 45 42 35 61 34 39 20 21 23 15 21 21 18 25 20 21 4 23 15 21 21 18 25 U-Value !Imperial) light to Solar Gain (LSG) Visible light % Total Solar Energy % Winter Nighttime Summer Daytime European U-Value Shading Coefficient Solar Heat Gain Coefficient 11 28 41 7 6 14 6 12 15 12 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.29 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 0.27 1.6 1.6 1.6 1.6 1.5 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.6 1.5 1.6 1.6 1.6 1.6 1.6 0.45 0.48 0.32 0.32 0.35 0.26 0.33 0.32 0.29 0.37 0.36 0.36 0.14 0.40 0.29 0.38 0.37 0.33 0.42 0.39 0.41 0.27 0.28 0.30 0.22 0.28 0.28 0.25 0.32 0.31 0.31 0.13 0.35 0.25 0.33 0.32 0.29 0.37 1.79 1.80 1.96 1.93 1.67 1.55 1.61 1.50 1.40 1.91 1.71 1.74 0.54 1.43 0.29 0.29 0.27 0.27 0.30 0.25 0.26 0.21 1.62 1.24 0.29 0.29 0.29 0.29 0.29 0.29 0.27 0.27 0.27 0.27 0.27 0.27 0.19 0.17 0.21 0.21 0.20 0.22 0.17 0.15 0.18 0.18 0.17 0.19 1.24 0.87 0.94 0.94 0.82 1.26 11•••••.•r"!Oll 'RI SOLARBAN 60 (2) Clear + Clear • Reflectance Total Solar Energy % , , . , , ••, ; 1 11·1 4 2 3 2 2 3 I 111111••11"•1 42 26 s.. ...... , •. 21 13 17 17 14 24 16 12 I ifill••I 8 6 9 9 8 10 11 8 8 8 6 7 7 6 9 9 9 4 8 6 7 7 7 10 7 7 5 15 7 13 16 13 ..... 10 10 20 11 19 10 14 14 11 24 10 8 15 18 14 15 I I 1.6 1.6 I 1.6 1.6 1.6 1.6 1.6 1.6 1.36 1.36 1.31 1.21 1.65 * Data based on using STARPH/RE9 glass for both interior and exterior lites. All performance data calculated using LBNL Window 6.3 software, except European LI-value, which is calculated using WinDat version 3.0. l software. For detailed information on the methodologies used to calculate the aesthetic and performance values in this table, please visit www.ppgideascapes.com or request our Architectural Glass Catalog. © 2014 PPG Industries, Inc. All rights reseived. Atlantica, Azuria, Azurlite, Graylite, ldeaScapes, Oceans of Color, Optiblue, Optigray, Pacifica, Solarban, Solarb/ue, Solarbronze, Solarcool, Solargray, So/ex, Solexia, Starphire, Sungate, Vistacool, the PPG logo and the PPG Certified Fabricator Network and the PPG Certified Programs are registered trademarks of PPG Industries Ohio, Inc. Cradle to Cradle Certified is a certification mark licensed by the Cradle to Cradle Products Innovation Institute. Ecological Solutions from PPG is a trademark of PPG Industries Ohio, Inc. ~· · crocleloa'Clcle Printed in U.S.A. Glass • Coatings • Paint 7071 09/14 10M PPG Industri es, Inc. idea7c:-ape~ Glass Business & Discovery Center 400 Guys Run Road Cheswick, PA 15024 1-888-PPG-IDEA www.ppgideascapes.com May 13, 2016 Irene Borba City of Belvedere Planning Department 450 San Rafael Ave, Belvedere, CA 94920-2336 PROJECT: 1.0r.: ~i?Vt: Wl?eHBAKEr< AIA ARltttrecrs 4 Pt.AHHE R~ ('/I'S) 'Wt la:ZO Carlisle Residence, 2 Cliff Road. Narrative of Work by Level Construction of the Building: The Existing Building has a combination of concrete and wood framed structure. The Improvements will be consistent with the structure of the existing building. New walls will be wood framed, where appropriate. New floors will be slab on grade or wood framed. New Foundations will be concrete. Structural steel will be used where required by the engineer. Main Level: The existing car port will be removed, a new formal entry will be added off the existing Auto Court. The new entry will have a higher roof that mirrors the profile of the existing great room roof. An elevator will be added off the entry to connect all the levels of the house. A new three car garage will also be added, adjacent to the new entry, to the north of the property. The existing hexagonal stairs will be removed, along with the associated poke out. A new stair will connect the main level with the existing guest suite and lower level. The existing kitchen and Master bedroom will be removed, and a new kitchen, breakfast area, family room and the second stair down to the lower level will added in that location. The existing covered veranda will be enclosed to accommodate a new master suite. The last two bays of the veranda will be removed completely, along with the existing site stairs and retaining walls. They will be replaced by a new deck off the master suite and site stairs that are no longer within the side yard setback. Lower Level: The existing library will be removed. Where the lower level deck is covered, a new enclosed space will follow the line of the structure. This will create a new study, powder room and sitting room. A new stair will be added descending to the new spa level. The storage room will be removed, and a new recreation room will replace it. A new bedroom wing with three bedrooms and three bathrooms will be added beneath the master suite, the existing structure will remain, but to gain the 9'·0" ceiling height, the retaining wall will be underpinned. A new patio will be added at the end of the bedroom wing that connects with the landscaping through a new site stair. Spa Level: A new level will be added within the envelope of the existing building. At this new level will be a wet bar, storage room, den and bath room. This new level will connect to a new patio with site stairs that descend to the existing pool and patio. May 13, 2016 ~rtvr: W16eHBAKEr< AIA: AWtrnc.r:=s 4 PLAHl--IE. R~ Irene Borba City of Belvedere Planning Department 450 San Rafael Ave, Belvedere, CA 94920-2336 PROJECT: r41r;> ~i; Carlisle Residence, 2 Cliff Road. Narrative of Work by Level Construction of the Building: The Existing Building has a combination of concrete and wood framed structure. The Improvements will be consistent with the structure of the existing building. New walls will be wood framed, where appropriate. New floors will be slab on grade or wood framed. New Foundations will be concrete. Structural steel will be used where required by the engineer. Main Level: The existing car port will be removed, a new formal entry will be added off the existing Auto Court. The new entry will have a higher roof that mirrors the profile of the existing great room roof. An elevator will be added off the entry to connect all the levels of the house. A new three car garage will also be added, adjacent to the new entry, to the north of the property. The existing hexagonal stairs will be removed, along with the associated poke out. A new stair will connect the main level with the existing guest suite and lower level. The existing kitchen and Master bedroom will be removed, and a new kitchen, breakfast area, family room and the second stair down to the lower level will added in that location. The existing covered veranda will be enclosed to accommodate a new maste1· suite. The last two bays of the veranda will be removed completely, along with the existing site stairs and retaining walls. They will be replaced by a new deck off the master suite and site stairs that are no longer within the side yard setback. Lower Level: The existing library will be removed. Where the lower level deck is cove1·ed, a new enclosed space will follow the line of the structure. This will create a new study, powder room and sitting room. A new stair will be added descending to the new spa level. The storage room will be removed, and a new recreation room will replace it. A new bedroom wing with three bedrooms and three bathrooms will be added beneath the master suite, the existing structure will remain, but to gain the 9'-0" ceiling height, the retaining wall will be underpinned. A new patio will be added at the end of the bedroom wing that connects with the landscaping through a new site stair. Spa Level: A new level will be added within the envelope of the existing building. At this new level will be a wet bar, storage room, den and bath room. This new level will connect to a new patio with site stairs that descend to the existing pool and patio. law RECEIVED MAY 1 6 2016 c·tty of Belved ere Add ress 135 BELVEDERE AVE 30 EUCALYPTUS RD 28 EUCALYPTUS RD 26 EUCALYPTUS RD 34 EUCALYPTUS RD 36 EUCALYPTUS RD 10 CLIFF RD 2 CLIFF RD 6 CLIFF RD 205 GOLDEN GATE AVE 32 EUCALYPTUS RD 8 CLIFF RD 201 GOLDEN GATE AVE 215 GOLDEN GATE AVE 270 BELVEDERE AVE 121 BELVEDERE AVE 209 GOLDEN GATE AVE 255 GOLDEN GATE AVE 217 GOLDEN GATE AVE 125 BELVEDERE AVE 29 EUCALYPTUS RD 213 GOLDEN GATE AVE p rop ID 060-181-07 060-182-10 060-182-11 060-182-12 060-182-08 060-202-11 060-201-04 060-201-10 060-201-02 060-182-20 060-182-09 060-201-03 060-182-35 060-182-18 060-202-10 060-181-25 060-182-23 060-202-17 060-182-19 060-181-26 060-182-17 060-182-22 Fl oor Area ** 3,764 2,261 2,507 2,807 2,340 3,318 3,641 12,765 5,680 5,449 6,250 6,392 6,182 4,847 4,323 5,513 4,841 10,445 6,928 6,497 3,303 4,590 * MarinMap data based on County Assessor Records * CofB is City of Belvedere record ** Latest available data LOTS F 52,965 31,382 28,880 28,750 21, 147 21, 198 19,685 60,296 23,798 22,003 23,727 23,483 22,647 17,421 15,394 18,667 16, 135 29,364 19,272 17,783 7,826 6,175 FAR 7.1% 7.2% 8.7% 9.8% 11.1% 15.7% 18.5% 21.2% 23.9% 24.8% 26.3% 27.2% 27.3% 27.8% 28.1% 29.5% 30.0% 35.6% 35.9% 36.5% 42.2% 74.3% Year of Data 2004 1962 1951 1951 1952 1995 1976 2016 2001 1995 2011 2002 2008 2003 2002 2016 2000 1989 2007 2007 1962 2012 s ource* CofB Marin map Marin map Marinmap Marinmap CofB Marin map proposed CofB CofB CofB CofB CofB CofB CofB CofB CofB Marin map CofB CofB Marin map CofB ZONE R15 R15 R15 R15 R15 R15 R15 R15 R15 R15 R15 R15 R15 R15 R15 R15 R15 R15 R15 R15 R15 R15 approved 2016 TIBURON FIRE PROTECTION DISTRICT 1679 TIBURON BOULEVARD, TIBURON, CALIFORNIA 94920 TELEPHONE ( 415) 435-7200 FAX: ( 415) 435-7205 RICHARD PEARCE, FIRE CHIEF TO: BELVEDERE PLANNING DEPARTMENT FROM: Jessica Power, Fire Marshal RE: 2 Cliff Road DATE: July 7, 2016 The proposed addition and remodel of the residence at 2 Cliff Road shall comply with the following requirements of the California Fire Code and the Tiburon Fire Protection District (TFPD): 1) The automatic fire sprinkler system shall be modified to properly protect the new and remodeled areas. The system design, installation and final testing shall be approved by the District Fire Prevention Officer. Due to the size of the structure, the system shall be designed to NFPA 13R standards. CFC 903.2 2) Approved smoke and carbon monoxide alarms shall be installed to provide protection to all sleeping areas. CFC 907.2.10 3) Access gates shall be operable using the Fire District's "Knox" key system. CFC 503.6.2 4) The vegetation on this parcel shall comply with the requirements of TFPD. CFC 304.1.2 5) Access shall extend to within 150 feet of all portions of the facility and all portions of the exterior walls of the first story of the building as measured by an approved route around the exterior of the building or facility. CFC 503.1.1 The access does not comply. As an alternate means of protection you have proposed to add a standpipe with connection at the street and a connection at the lowest floor at the furthest point of the exterior on the residence. We accept this proposal. ATTACHMENT7 PROTECTING THE COMMUNITIES OF BELVEDERE AND TIBURON TIBURON FIRE PROTECTION DISTRICT 1679 TIBURON BOULEVARD, TIBURON, CALIFORNIA 94920 TELEPHONE (415) 435-7200 FAX: (415) 435-7205 RICHARD PEARCE, FIRE CHIEF 3) The fire department access road (Cliff Road) shall comply with TFPD Policies, 425.3 Fire Department access, 425.5 Driveway and Road Widths, 425.9 Driveway and Roadway Turning Radius, 425.11 Driveway and Roadway Maximum slope of Grade. Information on slope, easements, and other roadway information is required for evaluation. Cliff Road does not comply. Per our site meeting, the road will be maintained at a minimum of 12'. Thank you for the opportunity to review the plans. cc: file PROTECTING THE COMMUNITIES OF BELVEDERE AND TIBURON MARIN MUNICIPAL WATER DISTRICT 220 Nellen Avenue Corte Madera CA 94925-1169 www.marinwater.org April 11, 2016 Service No. 22137 Irene Borba Belvedere Planning Dept. 450 San Rafael Ave. Belvedere, CA 94920 RE: WATER AVAILABILITY - Single Family Dwelling Assessor's Parcel No.: 060-201-10 Location: 2 Cliff Rd., Belvedere Dear Ms. Borba: The above referenced parcel is currently being served. The purpose and intent of this service are to provide water to a single family dwelling. The proposed remodeling and major addition to the existing structure will not impair the District's ability to continue service to this property. Compliance with all indoor and outdoor requirements of District Code Title 13 - Water Conservation is a condition of water service. Indoor plumbing fixtures must meet specific efficiency requirements. Landscape plans shall be submitted, and reviewed to confirm compliance. The Code requires a landscape plan, an irrigation plan, and a grading plan. Any questions regarding District Code Title 13 - Water Conservation should be directed to the Water Conservation Department at 415-945-1497. You can also find information about the District's water conservation requirements online at www.marinwater.org. Should backflow protection be required, said protection shall be installed as a condition of water service. Questions regarding backflow requirements should be directed to the Backflow Prevention Program Coordinator at 415-945-1558. The District has determined this project will not be required to install a gray water recycling system. If you have any questions regarding this matter, please contact me at 415-945-1531. Sincerely, ChrisBo~r Engineering Technician CB recycled recyclable June 30, 2016 City of Belvedere Design Review Comments 2 Cliff Road City Engineer - Review Comments Review of the Carlisle Residence (Revised Plans) - submitted June 20, 2016: The Public Works Department has reviewed the subject application and no additional comments for the Design Review application. Should plans be submitted for Building Permit, the following conditions of approval shall be satisfied: Conditions of Approval: 1. An Encroachment Permit is required for all improvements, work activities, and staging or storage of equipment and materials within the public right of way, subject to approval of the Public Works Manager. 2. An updated Revocable License may be required for private improvements within the public right-of-way and easements. 3. A Geotechnical Investigation or geotechnical review letter is required. The geotechnical investigation/letter should address site preparation, foundation, grading and drainage recommendations. The Geotechnical Engineer of record shall review the proposed Grading & Drainage Plans for conformance with their recommendation prior to Building Permit issuance. 4. The project will require a detailed Grading Plan & Drainage Plan showing cut and fill earth volumes. Said plans shall incorporate, as appropriate, the MCSTOPPP Guidance for Applicants: Stormwater Quality Manual for Development Project in Marin County. This can be found at the following website: (http://www.marincounty.org/depts/pw/divisions/mcstoppp/development/~/media/Files/Depa rtments/PW/mcstoppp/GuidanceforApplicantsv 2508.pdf). 5. The project requires a Site Plan showing the property line locations (referencing the survey source and mapping information), any existing easements, building setbacks, encroachments etc. 6. Topographic Survey information shall be included either on the site plan or on a separate plan. The basis for determining elevations (assumed, NGVD, or NAVO) should also be clearly indicated. The surveyor's name and license number shall be included. City Engineer Review Comments - 2 Cliff Road June 30, 2016 Page 2 of 2 7. The project will require a Utility Plan (if not shown on the Site Plan) showing the existing site utilities and their alignment and locations, along with any proposed new locations or alignments for sewer, water, irrigation, gas, electrical, telephone, cable TV, etc. 8. The project will require an Erosion Control Plan incorporating, as appropriate, the MCSTOPPP Minimum Erosion/Sediment Control Measures for Small Construction Projects (http://www.marincounty.org/depts/pw/divisions/mcstoppp/development/"'/media/Files/Depa rtments/PW/mcstoppp/development/MECM final 2009.pdf) 9. The existing 3-foot drainage easement (title exception 15) shall be investigated to determine if it is currently being utilized. If there is a benefit to the City of Belvedere or other entity an equivalent alternate easement shall be provided around the residence as may be appropriate and desirable. End of comments. CITY OF BELVEDERE 450 San Rafael A venue 1. Belvedere, CA 94920 Tel: 415 / 435-3838 i. Fax: 415 / 435-0430 Memorandum: Building Department 2nd round comments on revised plans submitted May 16, 2016, for Design Review application Date: June 2, 2016 To: Irene Borba, City Planner CC: From: Eric Banvard, Building Official Project Location: 2 Cliff Road Project Description: Design Review and Exception to Floor Area Applications for: Major remodel and additions to existing dwelling; new 3-car attached garage; etc. per the proposed plans. The Building Department has reviewed the plans and documents resubmitted to the City on May 16, 2016. We have no additional concerns or comments for these entitlements for the project at this time. Please refer to the original comments from our Memorandum of April 12, 2016. Please let me know if there are any questions or concerns regarding the previous Building Department comments. Thanks, I ;::;;;&~--*/ Eric Banvard Building Official City of Belvedere ebanvard@cityofbelvedere.org Page 1of1 CITY OF BELVEDERE 450 San Rafael A venue i. Belvedere, CA 94920 Tel: 415 / 435-3838 i. Fax: 415 / 435-0430 Memorandum: Building Department comments for Design Review application Date: April 12, 2016 To: Irene Borba, City Planner CC: From: Eric Banvard, Building Official Project Location: 2 Cliff Road Project Description: Design Review and Exception to Floor Area Applications for: Major remodel and addition to existing dwelling; new 3-car attached garage; etc. per the proposed plans. The Building Department has the following comments for this project based on the information submitted or available at this time, for inclusion with the Planning Department Design Review: Comments related to the Planning applications: 1) The Building Department has no comments regarding the Design Review and Exception to Floor Area Applications. The Building Department can approve the current drawings submitted for this planning entitlement. Comments related to the future submittal for the Building Permit: 2) The submittal for the future Building Permit (BP) must detail the construction of the proposed alterations and improvements, including compliance with the California Residential and Energy Codes, geotechnical, engineering and structural aspects, etc. 3) The project has an estimated cost over $500,000, and would therefore be assigned a maximum 18 month Construction Time Limit (CTL). 4) The applicant may wish to consider requesting an additional 6 month extension of the CTL, for a total of24 months, from the Planning Commission. See Section 20.04.035D of the Belvedere Municipal Code for the full process and grounds for such an extension. 5) No other Building Department issues are foreseen at this time. Full compliance with all relevant Codes, will be conducted during the thorough plan review process by all involved agencies, after submittal of application, plans and related documents for a building permit. Please let me know if there are any questions or concerns regarding these Building Department comments; we are here to help. Thanks, ! ~~ Eric Banvard Building Official City of Belvedere ebanvard@cityofbelvedere.org Page 1of1 Irene Borba - City Planner From: Sent: To: Subject: Buehmann, Erik@BCDC <erik.buehmann@bcdc.ca.gov> Friday, April 08, 2016 3:06 PM Irene Borba - City Planner 2 Cliff Road Addition/Remodel - BCDC Hello Ms. Borba, BCDC has received the City of Belvedere's Design Review document for addition and remodel to an existing single family residence located at 2 Cliff Road in the City of Belvedere. It is difficult for us to make a definitive determination from the plans provided, but it appears that some of the development may occur within BCDC's 100-foot shoreline band jurisdiction. BCDC's shoreline band jurisdiction is located 100-feet inland from the edge of the Bay, which is defined by the Mean High Tide Line or the inland edge of marsh vegetation {5 feet above mean sea level}. A permit from BCDC would be required for any work within BCDC's jurisdiction. Our records show no previous permit has been issued for this site. Therefore, a new administrative permit would be required. Please let me know if you have any questions. Erik Buehmann Principal Permit Analyst San Francisco Bay Conservation & Development Commission 455 Golden Gate Ave., Suite 10600 San Francisco, CA 94102 415.352.3645 erikb@bcdc.ca.gov 1