SE3110BT TEMPEST RACK SHIELDED COMMS CABINET PRODUCT DATASHEET Features For TEMPEST applications SDIP-27 Level A Compliance 10U, standard 19” rack format Extensive customisable options Integration and testing services Additional Security features TEMPEST communications enclosure Description The SE3110BT shielded cabinet enables the use of unmodified COTS equipment in a TEMPEST application and is ideally sized to provide a complete deployable ‘plug and play’ communications solution. Shown above is a 10U example configuration with UPS, external Keyboard Video and Mouse connections can be provided or a rackmount KVM solution provided. An integrated UPS can be installed ensuring continued operation or graceful shutdown in case of a power outage. SST also provides a range of integration, documentation and test services including formal testing of a configured system to SDIP-27 Level A. This service ensures that our customers receive a fully integrated, working, tested and documented system with appropriate compliances ready to be switched on and perform its desired function. Because the rack itself is not an item of active data processing equipment it cannot itself be classed as TEMPEST. Only after testing with equipment installed can the cabinet be tested to SDIP-27 for compliance to TEMPEST standard. The SE3110BT complements the large range of TEMPEST products and services available from SST, more details of which can be found at www.sst.ws Secure Systems & Technologies Ltd +44 (0)1452 371999 E-mail: info@sst.ws http://www.sst.ws SE3110BT TEMPEST RACK SHIELDED COMMS CABINET PRODUCT SPECIFICATION MAIN FEATURES TEMPEST TEMPEST to SDIP-27 Level A or Level B NATO Zone 0 (AMSG720B) Performance For SDIP-27 Level A applications Cabinet features 19” rack standard for COTS installation Power filtering and internal distribution Cable management Multi-point door closing and gasket compression Locking front door handle Modular lightweight chassis Attractive textured paint exterior Castors Interfaces Designed for Customer interface requirements Compliance CE Compliant Safety to BSEN60950 (power components) ENVIRONMENTAL Physical Height 10U (internal rack estate) Width 700 mm Depth 600-1000 mm (to order) Power 48VDC, 110 VAC, 230 VAC, 3 Phase Filtered Red and Black power separation OPTIONS SST Integration options System design and documentation Cleared personnel: Installation site surveys Human factors report Installation and cabling services System documentation and training Regulatory Compliance services Military EMC (Def Stan 59-411) compliance Test plan and acceptance testing TEMPEST Test plan for CESG approval TEMPEST testing of configured system UK Government (CESG) TEMPEST Endorsement Temperature Dependant on internal equipment Security options Government secure lock and internal fixed panel Door-open interlock and/or alarm Example Rear interface panel Options Integrated UPS power protection Power distribution and circuit protection Remote (IP) equipment power shutdown Automatic fire extinguishing system Environmental monitoring and remote reporting Temperature controlled fans Dust filters Wooden packing crate for worldwide transport Other cabinet formats Secure Systems & Technologies Ltd Waterwells, Gloucester GL2 2AL, England +44 (0)1452 371999 E-mail: info@sst.ws E & O E, Subject to change without notice http://www.sst.ws Issued 22/07/2009 SE3110BT TEMPEST SDIP-27 level A Rack Cabinet Data Sheet 8247-19-002_2