SE3124TF TEMPEST RACK
SHIELDED CABINET
PRODUCT DATASHEET
Features
•
For TEMPEST applications
•
24U, standard 19” rack format
•
Extensive customisable options
•
Integration and testing services
•
Easily deployed,
•
SDIP-27 Level A Compliance
Description
The SE3124TF shielded cabinet enables the use of COTS equipment in a TEMPEST application
and is ideally sized to provide a complete server, storage and communications solution.
The use of a transportable shielded cabinet enables integration and testing to be completed at a
central site before deploying a fully working solution, thereby reducing travel and onsite services
expenditure. SST provides a range of integration, documentation and test services including
formal testing of a configured system to SDIP-27 Level A. This service ensures that our
customer receives a fully integrated, working, tested and documented system with appropriate
compliances ready to function.
The SE3124TF cabinet has been designed to provide sufficient shielding to enable installation in
an environment requiring TEMPEST protection. Because the rack itself is not an item of active
data processing equipment it cannot itself be classed as TEMPEST. Only after testing with a
defined configuration of equipment, interconnected and cable routed to a defined plan, can the
cabinet be tested to SDIP-27 for compliance to TEMPEST standard.
The SE3118TF compliments the large range of TEMPEST products and services available from
SST, more details of which can be found at www.sst.ws
Secure Systems & Technologies Ltd
+44 (0)1452 371999
E-mail: info@sst.ws
http://www.sst.ws
SE3124TF TEMPEST RACK
SHIELDED CABINET
PRODUCT SPECIFICATION
MAIN FEATURES
Performance
Minimum 60dB from 100MHz through 10GHz
For SDIP-27 Level A applications
Cabinet features
19” rack standard for COTS installation
Power distribution
Cable management
Multi-point door closing and gasket compression
Locking front door handle
Modular lightweight chassis
Attractive painted exterior
Interfaces
Designed for Customer interface requirements
TEMPEST
TEMPEST to SDIP-27 Level A or Level B
NATO Zone 0 (AMSG720B)
Compliance
CE Compliant
Safety to BSEN60950 (power components)
ENVIRONMENTAL
Physical
Height 24U (internal rack estate)
Width 700 mm
Depth 700-1000 mm (to order)
Power
48VDC, 110 VAC, 230 VAC, 3 Phase
Red and Black power filter separation
OPTIONS
SST Integration options
System design and documentation
Cleared personnel: Installation site surveys
Human factors report
Installation and cabling services
System documentation and training
Regulatory Compliance services
Military EMC (Def Stan 59-411) compliance
Test plan and acceptance testing
TEMPEST Test plan for CESG approval
TEMPEST testing of configured system
UK Government (CESG) TEMPEST Endorsement
Temperature
Dependant on internal equipment
Security options
Secure KVM switch
Door-open interlock
Door-open alarm
Options
Integrated UPS power protection
Power distribution and circuit protection
Remote (IP) equipment power shutdown
Automatic fire extinguishing system
Environmental monitoring and remote reporting
Temperature controlled fans
Dust filters
Wooden packing crate
Removable eye-bolt lift options
Example of lower rear interface panel
Secure Systems & Technologies Ltd
Waterwells, Gloucester
GL2 2AL, England
+44 (0)1452 371999
E-mail: info@sst.ws
E & O E, Subject to change without notice