IND6/12/24 - Boston Light Source

advertisement
Catalog Number
Notes
Type
FEATURES
INTENDED USE
Provides minimum of 90 minutes of illumination for rated wattage upon loss
of AC power. Unique design for light and heavy industrial applications, as
well as heavy commercial environments. Superior performance lamp heads
are ideal for higher mounting heights.
CONSTRUCTION
Rugged front and navy back (std. colors) .140” thick, injection-molded thermoplastic (large back housing is .187” thick, compression-molded composite).
Vertical orientation, designed for pole or column mounting. Also suitable for
wall, I-beam and unistrut mounting. Ceiling and pendant mounting with accessory equipment available on some models. Easy installation with
epoxy-coated, corrosion-resistant, 12-gauge steel mounting bracket
shipped standard. U.S. Patent No. 6,135,624 - Mounting Bracket Utility patent.
Conduit entry points located on top and both sides of unit. Maintenance made
easy by tool-less lamp replacement, hinged front cover, printed circuit board
mounting shelf and battery belt. U.S. Patent No. D419,097 - Design patent.
LAMPS
U.S. Patent No. 6,193,395 - Lamp Head Utility patent. Full range of lamp options
available from 9W to 50W in sealed-beam or composite versions of incandescent, krypton or halogen lamps. Composite lamps feature unique field-adjustable beam spread (by turning lamp bezel). Standard lamp is 9W krypton for 6V
and 12V. Standard lamp is 18W incandescent for 24V.
BATTERY
Sealed, maintenance-free, lead-calcium battery with capacity of 18W to
450W for 90 minutes of emergency operation. Available in 6V, 12V or 24V.
Low-voltage disconnect prevents excessively deep discharge that can permanently damage battery.
Premium and Ultimate options offer high-temperature batteries (IND618,
IND1236 and IND12100 only). UL listed from 0° C to 55° C (Premium) or -40° C to
55° C (Ultimate).
ELECTRONICS
Brownout protection is standard feature of self-diagnostics.
AC/LVD reset prevents battery damage from deep discharge.
Current limiting charger.
Thermal protection prevents overheating and charger failure.
Thermal compensation provides optimum charge voltage relative to ambient temperature.
Dual voltage input capacity 120/277.
Industrial Emergency Lighting Unit
IND6/12/24
6, 12 or 24 Volts
Sealed Lead-Calcium
or Ni-Cad Battery
DIAGNOSTICS (with Select, Premium and Ultimate packages)
US Patent No. 6,502,044 - Self Diagnostics utility patent.
Single multi-chromatic LED indicator displays two-state charging, test activation and three-state diagnostic status.
Self-diagnostic testing for five minutes every 30 days and 30 minutes every
six months. Diagnostic evaluation of lamp, AC to DC transfer, charging and
battery condition.
Load learning capability self-calibrates to DC load at first test, enabling it to
detect a lamp failure on future tests. May be re-calibrated at any time by
holding down test switch for 15 seconds.
LISTING
UL Listed. Damp location listing. Meets UL 924, NFPA 101, NFPA 101-NEC and
OSHA illumination standards.
WARRANTY
Three-year total customer satisfaction warranty.
ORDERING INFORMATION
Family
6 Volts
IND618 18W
IND654 54W
IND6100 100W1
12 Volts
IND1236 36W
IND1254 54W
IND12100 100W
IND12150 150W
IND12300 300W
IND12450 450W
24 Volts
IND24100 100W
IND24450 450W 1
Housing Color
(blank) Gray front/
Navy back
W White
Accessories
Order as separate items.
ELA RTT Remote test
transmitter2
ELA WG2M Wire guard - small
(18W-100W)
ELA WGLG Wireguard - large
(150-450W)
ELA BS Banding strap
ELA IND PM Pendant mount kit
for IND618/654/6100
1236/1254/12100/24100 4
ELA IND CM1 Ceiling mount kit
for IND618
ELA IND CM2 Ceiling mount kit
for IND654/1236/1254
ELA IND CM3 Ceiling mount kit
for IND6100
ELA IND R3 Pre-pack to install
third head
Emergency
Example:
Option Packages
Lamp Type (2 heads)
6 Volts
PAR36 Composite
(blank) 9W/6V krypton
H1206 12W/6V halogen
H2006 20W/6V halogen
12 Volts
PAR36 Composite
(blank) 9W/12V krypton
H1212 12W/12V halogen
H2012 20W/12V halogen
PAR36 Sealed-Beam
H3512S 35W/12V halogen
H5012S 50W/12V halogen
24 Volts
PAR36 Composite
(blank) 18W/24V incand.
H2024 20W/24V halogen
PAR36 Sealed-Beam
N5024S 50W/24V incand.
IND1236 H1212 ULT
(blank) Damp location 10° C to 40° C (50° F to 104° F).
XTRA 2 Extra package. Features remote test, time delay
and damp location 10° C to 40° C (50° F to 104° F).
SEL Select package. Features self-diagnostics, time
delay, audible failure indication and damp
location 10° C to 40° C (50° F to 104° F).
PREM 3 Premium package. Features high-temperature
ni-cad battery (IND618 and IND1236 only) or
high-temperature lead calcium battery
(IND12100 only), self-diagnostics, time delay,
audible failure indication and damp location. UL
listed for 0° C to 55° C (32° F to 131° F).
ULT 3 Ultimate package. Features heater, thermostat
and battery blanket with a high temperature nicad battery (IND618 and IND1236 only) or hightemperature lead-calcium battery (IND12100
only), self-diagnostics, time delay, audible failure
indication and damp location. UL listed for -40° C
to 55oC (-40° F to 131° F).
NOTES:
1
2
3
4
DL listed for indoor applications.
Must order a Remote transmitter (ELA RTT). One per job required.
Only available on IND618, IND1236 and IND12100.
ELA IND PM accessory cannot be used with the IND12100 PREM or
IND12100 ULT.
Sheet #: IND6-12-24
INUE-100
IND6-12-24 INDURA Industrial Emergency Lighting Units, 6/12/24 Volts
SPECIFICATIONS
MOUNTING
ELECTRICAL
Primary Circuit
All dimensions are in inches (millimeters).
Shipping weight:
IND618 - 13 lbs.
IND654 - 18 lbs.
IND6100 - 23 lbs.
IND1236 - 18 lbs.
IND1254 - 18 lbs.
IND12100 - 27 lbs.
AC Input
Volts Amps
Watts
120
.163
19.6
Type
Output
Watts Output
Volts 1-1/2hr. 2hr.
3hrs.
IND618
277
120
.069
.172
19.11
20.64
277
120
.075
.171
20.78
20.5
277
120
.064
.174
17.7
20.9
277
120
.078
.174
21.61
20.88
IND654
IND1236
IND1254
.078
.174
21.6
20.88
277
120
.074
.359
20.49
43.08
277
120
.168
.290
46.54
34.8
277
120
.130
.33
36.1
39.96
277
120
.15
.33
43.77
39.6
6
18
13.5
9
6
6
54
40
27
20
IND12100
IND12150
IND12300
6
100
75
50
37
12
36
27
18
13
12
54
40
27
20
12
100
75
50
37
12
150
112
75
56
12
IND24100
.15
.773
41.55
92.76
277
.327
90.58
300
225
150
IND24450
Small Housing (18-54W;
100W Standard, XTRA, and SEL)
Small Housing
450
337
225
168
24
100
75
50
37
24
450
337
225
168
8.68
(220)
1 2.16
(25) (55)
0.40
(10)
12.5
(317)
12.5
(317)
.20(5)
2.48(63)
2.76(70)
ELA IND K0906
One (1) 9 Watt Krypton In Vertical, Base Up Position
Maintenance
6/12/24
3 yrs.
10 yrs.
none3
Operating
temperature2
32o-131 oF
(0 o-55 oC)
Lead-Calcium
Expected
life 1
Maintenance
5-8 yrs.
none3
Operating
temperature2
60o-90oF
(16o-32oC)
6
6
4
4
2
2
1
0
0.5
0.3
0
2
2
4
4
6
Voltage
Expected
life 1
Maintenance
6/12/24
1 yr.
5-8 yrs.
none3
Operating
temperature2
32o-131 oF
(0 o-55 oC)
1
0.5
0.3
1
0.5
0.3
6
VERTICAL
VERTICA
VERTICAL
VERTICA
6
6
4
4
2
1
0
Shelf
life
.
HORIZONTAL
2
High-Temperature Lead-Calcium
0.5
0.3
0
2
2
4
4
6
6
10
20
30
40
Ft
Ft.
10
20
30
Ft.
Ft
PERFORMANCE DIAGRAMS
1 Based on normal room temperatures and conditions.
2 Optimum ambient temperature range where unit will provide rated capacity for 90
minutes. Higher and lower temperatures affect life and capacity.
3 Periodic system status test recommended.
Center-to-center
spacing* yields 25.5'.
25.5'
KEY FEATURES
FLOOD
IND K0906
Medium Distribution
MEDIUM
SPOT
12-gauge epoxy-coated steel
mounting bracket included with
each unit.
Field-adjusted beam pattern
for composite lamps.
ELA RTT
Order remote transmitter
separately.
*Note: Meets Life Safety Code standard
minimum illuminance of 0.1 FC and
average illuminance of 1.0 FC. Assumes
space of 200'L x 200'W x 30'H, mounting
height: 12', ceiling height: 30', and
reflectances: 10/10/10. Analysis based
on independently tested photometrics.
Center-to-center
spacing* yields 26'.
3'
26'
IND K0912
Medium Distribution
3'
Lithonia Lighting
Sheet #: IND6-12-24
.68
(17)
ELA IND K0912
One. (1) 9 Watt Krypton In Vertical, Base Up Position
HORIZONTAL
Expected
life 1
1 yr.
8.32
(211)
9
(228)
PHOTOMETRICS
Shelf
life
6/12/24
Mounting Bracket
12
(305)
112
12
Voltage
Voltage
16
(406)
16
(406)
BATTERY
High-Temperature Nickel-Cadmium
Shelf
life
13.25
(336)
16
(406)
8
(203)
IND12450
277
120
Large Housing (100W
PREM
and ULT; 150-450W)
Large
Housing
18
(457)
IND6100
277
120
4hrs.
IND12150 - 45 lbs.
IND12300 - 72 lbs.
IND12450 - 75 lbs.
IND24100 - 27 lbs.
IND24450 - 75 lbs.
©2004 Acuity Lighting Group, Inc., Rev. 07/06
Emergency Lighting Systems
One Lithonia Way, Conyers, GA 30012
Phone: 800-334-8694
www.lithonia.com
Download