Catalog Number Notes Type FEATURES INTENDED USE Provides minimum of 90 minutes of illumination for rated wattage upon loss of AC power. Unique design for light and heavy industrial applications, as well as heavy commercial environments. Superior performance lamp heads are ideal for higher mounting heights. CONSTRUCTION Rugged front and navy back (std. colors) .140” thick, injection-molded thermoplastic (large back housing is .187” thick, compression-molded composite). Vertical orientation, designed for pole or column mounting. Also suitable for wall, I-beam and unistrut mounting. Ceiling and pendant mounting with accessory equipment available on some models. Easy installation with epoxy-coated, corrosion-resistant, 12-gauge steel mounting bracket shipped standard. U.S. Patent No. 6,135,624 - Mounting Bracket Utility patent. Conduit entry points located on top and both sides of unit. Maintenance made easy by tool-less lamp replacement, hinged front cover, printed circuit board mounting shelf and battery belt. U.S. Patent No. D419,097 - Design patent. LAMPS U.S. Patent No. 6,193,395 - Lamp Head Utility patent. Full range of lamp options available from 9W to 50W in sealed-beam or composite versions of incandescent, krypton or halogen lamps. Composite lamps feature unique field-adjustable beam spread (by turning lamp bezel). Standard lamp is 9W krypton for 6V and 12V. Standard lamp is 18W incandescent for 24V. BATTERY Sealed, maintenance-free, lead-calcium battery with capacity of 18W to 450W for 90 minutes of emergency operation. Available in 6V, 12V or 24V. Low-voltage disconnect prevents excessively deep discharge that can permanently damage battery. Premium and Ultimate options offer high-temperature batteries (IND618, IND1236 and IND12100 only). UL listed from 0° C to 55° C (Premium) or -40° C to 55° C (Ultimate). ELECTRONICS Brownout protection is standard feature of self-diagnostics. AC/LVD reset prevents battery damage from deep discharge. Current limiting charger. Thermal protection prevents overheating and charger failure. Thermal compensation provides optimum charge voltage relative to ambient temperature. Dual voltage input capacity 120/277. Industrial Emergency Lighting Unit IND6/12/24 6, 12 or 24 Volts Sealed Lead-Calcium or Ni-Cad Battery DIAGNOSTICS (with Select, Premium and Ultimate packages) US Patent No. 6,502,044 - Self Diagnostics utility patent. Single multi-chromatic LED indicator displays two-state charging, test activation and three-state diagnostic status. Self-diagnostic testing for five minutes every 30 days and 30 minutes every six months. Diagnostic evaluation of lamp, AC to DC transfer, charging and battery condition. Load learning capability self-calibrates to DC load at first test, enabling it to detect a lamp failure on future tests. May be re-calibrated at any time by holding down test switch for 15 seconds. LISTING UL Listed. Damp location listing. Meets UL 924, NFPA 101, NFPA 101-NEC and OSHA illumination standards. WARRANTY Three-year total customer satisfaction warranty. ORDERING INFORMATION Family 6 Volts IND618 18W IND654 54W IND6100 100W1 12 Volts IND1236 36W IND1254 54W IND12100 100W IND12150 150W IND12300 300W IND12450 450W 24 Volts IND24100 100W IND24450 450W 1 Housing Color (blank) Gray front/ Navy back W White Accessories Order as separate items. ELA RTT Remote test transmitter2 ELA WG2M Wire guard - small (18W-100W) ELA WGLG Wireguard - large (150-450W) ELA BS Banding strap ELA IND PM Pendant mount kit for IND618/654/6100 1236/1254/12100/24100 4 ELA IND CM1 Ceiling mount kit for IND618 ELA IND CM2 Ceiling mount kit for IND654/1236/1254 ELA IND CM3 Ceiling mount kit for IND6100 ELA IND R3 Pre-pack to install third head Emergency Example: Option Packages Lamp Type (2 heads) 6 Volts PAR36 Composite (blank) 9W/6V krypton H1206 12W/6V halogen H2006 20W/6V halogen 12 Volts PAR36 Composite (blank) 9W/12V krypton H1212 12W/12V halogen H2012 20W/12V halogen PAR36 Sealed-Beam H3512S 35W/12V halogen H5012S 50W/12V halogen 24 Volts PAR36 Composite (blank) 18W/24V incand. H2024 20W/24V halogen PAR36 Sealed-Beam N5024S 50W/24V incand. IND1236 H1212 ULT (blank) Damp location 10° C to 40° C (50° F to 104° F). XTRA 2 Extra package. Features remote test, time delay and damp location 10° C to 40° C (50° F to 104° F). SEL Select package. Features self-diagnostics, time delay, audible failure indication and damp location 10° C to 40° C (50° F to 104° F). PREM 3 Premium package. Features high-temperature ni-cad battery (IND618 and IND1236 only) or high-temperature lead calcium battery (IND12100 only), self-diagnostics, time delay, audible failure indication and damp location. UL listed for 0° C to 55° C (32° F to 131° F). ULT 3 Ultimate package. Features heater, thermostat and battery blanket with a high temperature nicad battery (IND618 and IND1236 only) or hightemperature lead-calcium battery (IND12100 only), self-diagnostics, time delay, audible failure indication and damp location. UL listed for -40° C to 55oC (-40° F to 131° F). NOTES: 1 2 3 4 DL listed for indoor applications. Must order a Remote transmitter (ELA RTT). One per job required. Only available on IND618, IND1236 and IND12100. ELA IND PM accessory cannot be used with the IND12100 PREM or IND12100 ULT. Sheet #: IND6-12-24 INUE-100 IND6-12-24 INDURA Industrial Emergency Lighting Units, 6/12/24 Volts SPECIFICATIONS MOUNTING ELECTRICAL Primary Circuit All dimensions are in inches (millimeters). Shipping weight: IND618 - 13 lbs. IND654 - 18 lbs. IND6100 - 23 lbs. IND1236 - 18 lbs. IND1254 - 18 lbs. IND12100 - 27 lbs. AC Input Volts Amps Watts 120 .163 19.6 Type Output Watts Output Volts 1-1/2hr. 2hr. 3hrs. IND618 277 120 .069 .172 19.11 20.64 277 120 .075 .171 20.78 20.5 277 120 .064 .174 17.7 20.9 277 120 .078 .174 21.61 20.88 IND654 IND1236 IND1254 .078 .174 21.6 20.88 277 120 .074 .359 20.49 43.08 277 120 .168 .290 46.54 34.8 277 120 .130 .33 36.1 39.96 277 120 .15 .33 43.77 39.6 6 18 13.5 9 6 6 54 40 27 20 IND12100 IND12150 IND12300 6 100 75 50 37 12 36 27 18 13 12 54 40 27 20 12 100 75 50 37 12 150 112 75 56 12 IND24100 .15 .773 41.55 92.76 277 .327 90.58 300 225 150 IND24450 Small Housing (18-54W; 100W Standard, XTRA, and SEL) Small Housing 450 337 225 168 24 100 75 50 37 24 450 337 225 168 8.68 (220) 1 2.16 (25) (55) 0.40 (10) 12.5 (317) 12.5 (317) .20(5) 2.48(63) 2.76(70) ELA IND K0906 One (1) 9 Watt Krypton In Vertical, Base Up Position Maintenance 6/12/24 3 yrs. 10 yrs. none3 Operating temperature2 32o-131 oF (0 o-55 oC) Lead-Calcium Expected life 1 Maintenance 5-8 yrs. none3 Operating temperature2 60o-90oF (16o-32oC) 6 6 4 4 2 2 1 0 0.5 0.3 0 2 2 4 4 6 Voltage Expected life 1 Maintenance 6/12/24 1 yr. 5-8 yrs. none3 Operating temperature2 32o-131 oF (0 o-55 oC) 1 0.5 0.3 1 0.5 0.3 6 VERTICAL VERTICA VERTICAL VERTICA 6 6 4 4 2 1 0 Shelf life . HORIZONTAL 2 High-Temperature Lead-Calcium 0.5 0.3 0 2 2 4 4 6 6 10 20 30 40 Ft Ft. 10 20 30 Ft. Ft PERFORMANCE DIAGRAMS 1 Based on normal room temperatures and conditions. 2 Optimum ambient temperature range where unit will provide rated capacity for 90 minutes. Higher and lower temperatures affect life and capacity. 3 Periodic system status test recommended. Center-to-center spacing* yields 25.5'. 25.5' KEY FEATURES FLOOD IND K0906 Medium Distribution MEDIUM SPOT 12-gauge epoxy-coated steel mounting bracket included with each unit. Field-adjusted beam pattern for composite lamps. ELA RTT Order remote transmitter separately. *Note: Meets Life Safety Code standard minimum illuminance of 0.1 FC and average illuminance of 1.0 FC. Assumes space of 200'L x 200'W x 30'H, mounting height: 12', ceiling height: 30', and reflectances: 10/10/10. Analysis based on independently tested photometrics. Center-to-center spacing* yields 26'. 3' 26' IND K0912 Medium Distribution 3' Lithonia Lighting Sheet #: IND6-12-24 .68 (17) ELA IND K0912 One. (1) 9 Watt Krypton In Vertical, Base Up Position HORIZONTAL Expected life 1 1 yr. 8.32 (211) 9 (228) PHOTOMETRICS Shelf life 6/12/24 Mounting Bracket 12 (305) 112 12 Voltage Voltage 16 (406) 16 (406) BATTERY High-Temperature Nickel-Cadmium Shelf life 13.25 (336) 16 (406) 8 (203) IND12450 277 120 Large Housing (100W PREM and ULT; 150-450W) Large Housing 18 (457) IND6100 277 120 4hrs. IND12150 - 45 lbs. IND12300 - 72 lbs. IND12450 - 75 lbs. IND24100 - 27 lbs. IND24450 - 75 lbs. ©2004 Acuity Lighting Group, Inc., Rev. 07/06 Emergency Lighting Systems One Lithonia Way, Conyers, GA 30012 Phone: 800-334-8694 www.lithonia.com