P.O. Box 27 4300 AA Zierikzee The Netherlands Tel. +31 111 413656 Fax. +31 111 416919 www.deltapowersupplies.com DELTA ELEKTRONIKA B.V. External Module Card for inserting in power supply PSC-ETH - Ethernet Power Supply Controller Interface between Ethernet IP Network and Power Supply • Make use of existing networks • IP-addresss configurable by user • Build-in Card or External Module • Successor of the IEEE488 - bus Features • • • • 16-bit accuracy programming and monitoring Digital user in and outputs ( isolated) Change power supply modes (Remote/Local ,ect) Read-back of status signal • • • • Integrated Sequencer Software Calibration SCPI commands LabVIEW driver and Visual Basic example included • • • • Battery voltage simulation, Surges, Function generator, ect. 25 free sequences having max. 2000 each Combination of fast and very slow sequences Steps from 1 ms till hours Integrated Sequencer: Arbitrary Waveform generator or standalone automation. The sequencer is integrated in the Ethernet controller. User defined Waveforms can be stored in the sequencer. • Converts a power supply into an Arbitrary Waveform Generator • Ideal for repetitive testing and automotive • Can work like a PLC or stand-alone automation : steps interact with the actual in and outputs • Waveform generator independent of computer Stand-alone operating possible DELTA ELEKTRONIKA BV PSC-ETH The Sequencer The PSC-ETH can control the power supply by a sequence without the need of an external computer. The sequencer can even control the user outputs and read the user inputs. A sequence is built from user programmable steps (or program lines). A sequence step can do the following: • • • • Set the output Voltage and Current Jump to defined step number, unconditional or under condition of: Digital outputs, Digital inputs, Variable, output voltage or current Increment or Decrement output Voltage, Current or Variable • • • • Possibility to create loops, subroutines, ramps ect. Set a Digital output (6 available ) Wait for trigger from Computer or Pause Set a internal Variable (8 available) or an internal Timer (2 available) Sequences can be started / paused / stopped by : Commands via Ethernet (software) or by User Inputs (hardware). Using digital user inputs for starting or stopping a sequence, makes it possible to choose the sequences by selecting the corresponding input, without being connected to a computer. Analog inputs and outputs The 2 analog in- and outputs have a 16 bits resolution. Offset and full scale can be software calibrated. Input linearity error is +/- 1 LSB, output linearity error is +/- 2 LSB. TC typical is 10 ppm / °C. Each analog in- and output can be set or read. Analog voltages are standardized on 0 - 5 V. Analog in- and outputs have a common zero. Status monitoring The PSC provides logic status inputs to monitor the status signals of the power supply such as CC mode, current or voltage limit, DC fail, AC fail, Over Temperature, PSOL, etc. Controls Remote ShutDown: Enables / disables the output voltage of the power supply. REMOTE: Switches from manual control to remote control (not on PSC-ETH module) Digital User Inputs and Outputs The PSC-ETH provides eight 1000 V opto-isolated logic inputs with common zero for custom use. The input impedance is 1800 Ohm, Logic high = 2.5 ... 30 V, Logic low = 0 V. The PSC-ETH provides also six 1000 V opto-isolated, logic, open drain outputs with common zero for custom use. The output impedance is 7 Ohm, maximum rating is 30 V / 200 mA. Accessoiries PSC ETH built-in: PSC ETH module: CD-ROM with example software and manual in PDF format. CD-ROM with example software and manual in PDF format, Analog cable and Line Cord. Specifications external module PSC-ETH module Dimensions (h x w x d) Isolation 89 x 85.5 x 118.5 mm, 0.7 kg Input Power Wide range 98-264 V AC, 48-62 Hz Power consumption 10 W Hold-up time @ 110 V AC : 80 ms Hold-up time @ 230 V AC : 300 ms Ambient temperature Operating 0 to +55 °C Storage −20 to +70 °C Analog in- and outputs to case: Logic in- and outputs to case: Ethernet to case: Line input to case: 1000 V DC 1000 V DC 1000 V DC 2500 V AC EMC Emission : EN 61000-6-3, residential, light industrial environment EN 55022B Immunity : EN 61000-6-2, industrial environment Enclosure: IP20 Models Order Code Description Digital User I/O Comments ES 150 ES 300 SM 800 SM 1500 SM 3000 SM 6000 Option P150 Option P179 Option P256 Option P177 Option P149 Option P157 Not available Not available Available Available Not available Available Analog programming connector removed Analog programming connector removed Analog programming connector still available Analog programming connector still available Analog programming connector removed Analog programming connector still available** ES150 Series with Build-in Card ES300 Series with Build-in Card ES800 Series with Build-in Card ES1500 Series with Build-in Card ES3000 Series with Build-in Card ES6000 Series with Build-in Card **Note : Except on SM 600-10 and SM 300-20