INSTALLATION INSTRUCTIONS N2L LED EMERGENCY LIGHTING FIXTURE IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. Do not use outdoors. 2. Equipment should be mounted in locations and at heights where it will not be subject to tampering by unauthorized personnel. 3. Do not mount near gas or electric heaters. 4. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. 5. Do not use this equipment for anything other than its intended use. 6. Servicing of this equipment should be performed by qualified personnel only. 7. Disconnect AC power supply before servicing. Keyhole Knockouts Unit Connector IMPORTANT: The battery in this unit may not be fully charged. After electricity is connected to the unit for at least 24 hours, then normal operation of this unit should take effect. To check, press the “TEST” button. The LED lamps on the unit should turn on. Locking Tabs Conduit Entry Knockout In accordance with NFPA 101, your emergency lightin g system must be tested monthly for a minimum of 30 seconds and annually for 90 minutes. Refer to your local codes for any additional requirements that may apply. SAVE THESE INSTRUCTIONS WARNING: ALWAYS TURN OFF AC POWER TO THE EQUIPMENT BEFORE SERVICING. SERVICING SHOULD BE PERFORMED ONLY BY A QUALIFIED SERVICE TECHNICIAN. USE ONLY MANUFACTURER SUPPLIED REPLACEMENT PARTS. BATTERY The battery supplied with this unit requires no maintenance. However, it should be tested periodically and replaced when it no longer operates the lamp heads for the duration of 30 seconds. The battery in this unit has a life expectancy of 4 years when used in a normal ambient temperature of 72°F. WIRING DIAGRAM CHARGER BOARD AC INPUT CONNECTOR (MOUNTING PLATE) 277V RED 120V BLACK 0V WHITE Note: Unused input lead must be properly insulated with wire nut or other approved method. YELLOW(+) BLUE(-) YELLOW(+) BLUE(-) LAMP LAMP RED BLACK BATTERY READY TEST 1300 South Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • www.junolightinggroup.com ©2016 Acuity Brands Lighting, Inc. Printed in China REV-7/13 P5883 pg 1 of 2 INSTALLATION INSTRUCTIONS N2L LED EMERGENCY LIGHTING FIXTURE INSTALLATION INSTRUCTIONS (CONTINUED) FLEXIBLE CONDUIT ONLY Junction Box Mount Installation 1. Before starting installation, make sure that AC power is turned OFF. 2. Remove unit’s backplate by pushing through the two tabs at the bottom using a narrow screwdriver. 3. Feed fixture leads through back plate and connect to AC power leads coming into the junction box. 4. For 120V, connect the BLACK lead to HOT of the power supply and for 277V connect the RED lead. Connect the WHITE lead to NEUTRAL of the supply. Use a wirenut to cap off the unused lead. 5. Mount back plate on junction box and secure with screws. Unit 6. Connect battery only after continuous AC power can be provided to the unit. Connector 7. Align tabs and push housing directly onto the backplate. Apply continuous AC power. Keyhole Knockouts Keyhole Knockouts Unit Connector Locking Tabs Conduit Mount Locking Installation Tabs Conduit Entry Knockout 1. Before starting Conduit installation, make sure that AC power is turned OFF. Entry Knockout 2. Remove unit’s backplate by pushing through the two tabs at the bottom using a narrow screwdriver. 3. Secure backplate to wall surface using keyhole knockouts on the back. Use the conduit entry knockouts on the backplate and the unit’s housing for making the conduit connection. Route fixture leads through hole in conduit flange. 4. Make AC power connections. For 120V, connect the BLACK lead to HOT of the power supply and for 277V connect the RED lead. Connect the WHITE lead to NEUTRAL of the supply. Use a wirenut to cap off the unused lead. 5. Connect battery only after continuous AC power can be provided to the unit. 6. Align tabs and push housing directly onto the backplate. Apply continuous AC power. Wall/Ceiling Mount Installation WIRING DIAGRAM 1. Before starting installation, make sure that AC power is turned OFF. WIRING DIAGRAM 2. Remove unit’s backplate by pushing through the two tabs at the bottom using a narrow screwdriver. 3. Secure backplate to wall surface using keyhole knockouts on the back. CHARGER 4. Feed fixture leads through back plate and connect to AC power leads. For 120V, connect the BLACK lead to HOT of the power supply CHARGER and for 277V connect the RED lead. Connect the WHITE lead to NEUTRAL of the supply. Use a wirenut to cap off the unused lead. BOARD AC INPUT CONNECTOR BOARD 5. Connect battery only after continuous AC power can be provided to the unit. (MOUNTING PLATE) AC INPUT CONNECTOR Note: 6. Align (MOUNTING PLATE)tabs and push housing directly onto the backplate. Apply continuous AC power. RED 277V 277V 120V 0V Unused input lead must 120V BLACK be properly insulated with WHITE 0V wire nut or other approved WHITE 1. During an electrical power failure, the LED lamps will automatically come on for a minimum of 90 minutes. method. RED Operation BLACK Note: Unused input lead be properly insulat wire nut or other ap method. YELLOW(+) 2. To test, depress the “TEST” switch. The emergency LED lamps will illuminate. When the switch is released, the lamps will go off. YELLOW(+) BLUE(-) BLUE(-) YELLOW(+) YELLOW(+) LAMP WARRANTY BLUE(-) LAMP BLUE(-) Juno Lighting Group warrants that its products are free from defects in material and workmanship for one year from the date of purchase. Juno Lighting Group’s obligation is expressly limited to repair or replacement, without charge, at Juno Lighting Group’s factory after prior written LAMP return LAMP authorization has been granted. This warranty shall not RED apply to products which have been altered or repaired outside of Juno Lighting Group’s factory. This warranty is in lieu of all other warranties, BLACKexpressed or implied, and without limiting the generality of the foregoing phrase, excludes any implied warranty of merchantability. Also, there are no warranties which extend beyond the description of the product on the company’s literature setting forth terms of sale. Product Services TEST Phone (888) 387-2212 RED BLACK BATTERY BATTERY READY READY TEST 1300 South Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • www.junolightinggroup.com ©2016 Acuity Brands Lighting, Inc. Printed in China REV-7/13 P5883 pg 2 of 2