N2L LED EMERGENCY LIGHTING FIXTURE
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed, including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
1. Do not use outdoors.
2. Equipment should be mounted in locations and at heights where it will not be subject to tampering by unauthorized personnel.
3. Do not mount near gas or electric heaters.
4. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
5. Do not use this equipment for anything other than its intended use.
6. Servicing of this equipment should be performed by qualified personnel only.
7. Disconnect AC power supply before servicing.
Keyhole Knockouts
Unit
Connector
IMPORTANT:
The battery in this unit may not be fully charged. After electricity is connected to the
unit for at least 24 hours, then normal operation of this unit should take effect.
To check, press the “TEST” button. The LED lamps on the unit should turn on.
Locking Tabs
Conduit Entry Knockout
In accordance with NFPA 101, your emergency lightin g system must be tested monthly
for a minimum of 30 seconds and annually for 90 minutes. Refer to your local codes for
any additional requirements that may apply.
SAVE THESE INSTRUCTIONS
WARNING:
ALWAYS TURN OFF AC POWER TO THE EQUIPMENT BEFORE
SERVICING. SERVICING SHOULD BE PERFORMED ONLY BY A
QUALIFIED SERVICE TECHNICIAN. USE ONLY MANUFACTURER
SUPPLIED REPLACEMENT PARTS.
BATTERY
The battery supplied with this unit requires no maintenance. However,
it should be tested periodically and replaced when it no longer operates
the lamp heads for the duration of 30 seconds. The battery in this unit
has a life expectancy of 4 years when used in a normal ambient
temperature of 72°F.
WIRING DIAGRAM
CHARGER
BOARD
AC INPUT CONNECTOR
(MOUNTING PLATE)
277V
RED
120V
BLACK
0V
WHITE
Note:
Unused input lead must
be properly insulated with
wire nut or other approved
method.
YELLOW(+)
BLUE(-)
YELLOW(+)
BLUE(-)
LAMP
LAMP
RED
BLACK
BATTERY
READY
TEST
1300 South Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • www.junolightinggroup.com
©2016 Acuity Brands Lighting, Inc.
Printed in China
REV-7/13
P5883
pg 1 of 2
INSTALLATION INSTRUCTIONS
N2L LED EMERGENCY LIGHTING FIXTURE
INSTALLATION INSTRUCTIONS (CONTINUED)
FLEXIBLE CONDUIT ONLY
Junction Box Mount Installation
1. Before starting installation, make sure that AC power is turned OFF.
2. Remove unit’s backplate by pushing through the two tabs at the bottom using a narrow screwdriver.
3. Feed fixture leads through back plate and connect to AC power leads coming into the junction box.
4. For 120V, connect the BLACK lead to HOT of the power supply and for 277V connect the RED lead.
Connect the WHITE lead to NEUTRAL of the supply. Use a wirenut to cap off the unused lead.
5. Mount back plate on junction box and secure with screws.
Unit
6. Connect
battery only after continuous AC power can be provided to the unit.
Connector
7. Align tabs and push housing directly onto the backplate. Apply continuous AC power.
Keyhole Knockouts
Keyhole Knockouts
Unit
Connector
Locking Tabs
Conduit Mount Locking
Installation
Tabs
Conduit Entry Knockout
1. Before starting Conduit
installation,
make sure that AC power is turned OFF.
Entry Knockout
2. Remove unit’s backplate by pushing through the two tabs at the bottom using a narrow screwdriver.
3. Secure backplate to wall surface using keyhole knockouts on the back. Use the conduit entry
knockouts on the backplate and the unit’s housing for making the conduit connection. Route fixture
leads through hole in conduit flange.
4. Make AC power connections. For 120V, connect the BLACK lead to HOT of the power supply and
for 277V connect the RED lead. Connect the WHITE lead to NEUTRAL of the supply. Use a wirenut
to cap off the unused lead.
5. Connect battery only after continuous AC power can be provided to the unit.
6. Align tabs and push housing directly onto the backplate. Apply continuous AC power.
Wall/Ceiling Mount Installation
WIRING DIAGRAM
1. Before starting installation, make sure that AC power is turned OFF.
WIRING
DIAGRAM
2. Remove
unit’s backplate by pushing through the two tabs at the bottom using a narrow screwdriver.
3. Secure backplate to wall surface using keyhole knockouts on the back.
CHARGER
4. Feed fixture leads through back plate and connect to AC power leads. For 120V, connect the BLACK lead to HOT of the
power supply
CHARGER
and for 277V
connect the RED lead. Connect the WHITE lead to NEUTRAL of the supply. Use a wirenut to cap off the unused
lead.
BOARD
AC INPUT CONNECTOR
BOARD
5. Connect battery
only after continuous AC power can be provided to the unit.
(MOUNTING PLATE)
AC INPUT CONNECTOR
Note:
6. Align
(MOUNTING
PLATE)tabs and push housing directly onto the backplate. Apply continuous AC power.
RED
277V
277V
120V
0V
Unused input lead must
120V BLACK
be properly insulated with
WHITE
0V
wire nut or other approved
WHITE
1. During an electrical power failure,
the LED lamps will automatically come on for a minimum of 90 minutes.
method.
RED
Operation
BLACK
Note:
Unused input lead
be properly insulat
wire nut or other ap
method.
YELLOW(+)
2. To test, depress the “TEST” switch. The emergency LED lamps will illuminate. When the switch is released, the
lamps will go off.
YELLOW(+)
BLUE(-)
BLUE(-)
YELLOW(+)
YELLOW(+)
LAMP
WARRANTY
BLUE(-)
LAMP
BLUE(-)
Juno Lighting Group warrants that its products are free from defects in material and workmanship for one year from the date of purchase.
Juno Lighting Group’s obligation is expressly limited to repair or replacement, without charge, at Juno Lighting Group’s factory after prior written
LAMP
return
LAMP authorization has been granted. This warranty shall not
RED apply to products which have been altered or repaired outside of Juno Lighting
Group’s factory. This warranty is in lieu of all other warranties,
BLACKexpressed or implied, and without limiting the generality of the foregoing phrase,
excludes any implied warranty of merchantability. Also, there are no warranties which extend beyond the description of the product on the
company’s literature setting forth terms of sale.
Product Services TEST
Phone (888) 387-2212
RED
BLACK
BATTERY
BATTERY
READY
READY
TEST
1300 South Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • www.junolightinggroup.com
©2016 Acuity Brands Lighting, Inc.
Printed in China
REV-7/13
P5883
pg 2 of 2
Download