6" Horizontal Compact Fluorescent Open Retrofit Downlight DATE:TYPE: FIRM NAME: PROJECT: RLF6CFH One 26W, 32W, or 42W Triple Tube, 4-pin lamp or Ceiling Cutout: See Guide Maximum Ceiling Thickness: 1-1/2" For conversion to millimeters, multiply inches by 25.4 Not to Scale Two 26W Quad 120V-277V for 347V APPLICATIONS: SOCKET: The RLF6CFH series offers horizontally lamped compact fluorescent downlight fixtures designed specifically to retrofit into ceilings with existing recessed downlight fixtures without the need to remove the existing fixture. The multi-watt, multi-volt ballast provides the abillity to change wattages by simply changing the lamp. This luminaire is ideal for a wide variety of medium to high ceiling applications including commercial, retail, hospitality, and design-build. Injection molded socket(s) (vented). ED LAMP: *12-3/4" *15" For triple tube fixtures use one (1) 26W (GX24q-3 base), 32W (GX24q-3 base), or 42W (GX24q-4 base) 4-pin triple tube compact fluorescent lamp. For 26W (G24Q-3 base) quad tube 4-pin compact fluorecent lamps. Lamps furnished by others or as option below. HOUSING: LABELS: OPTICS: CSA/US listed for damp locations. CSA listed for wet locations with lensed trims. Approved for through wiring (4 in, 4 out). Non-IC type. Canadian required ballast disconnect standard. N High purity aluminum, Alzak, iridescence suppressed, semi-diffuse reflector. Self-trim standard. Painted white self-trim (WT) available as option. Baffled units standard with painted white self-trim. U All installation can be performed from below the ceiling without removing existing fixture. REFLECTOR: *Dimensions shown are for range of adjustability LAMP INCLUDED OPTION: TI BALLAST: CO N One (1) class 'P' 120V-277V HPF compact flourescent electronic ballast for long life and quiet operation. All ballast options are equipped with end of life protection. Contact technical support for 347V. Accessible from below ceiling. Order housing, reflector and accessories separately. *7-7/8" *9-3/4" CATALOG NUMBER: 5 HOUSING OPTIONS - EXAMPLE: RLF6CFH132EB 6CFH1 LP32T30K REFLECTOR COLOR REFLECTOR ❑SD2 ❑6CFH1 Small Diameter Housing 6" Alzak Semi-Diffuse ❑FSDFA one lamp Fuse kit installed at factory ❑6CFH ❑RIF1 6" Alzak Semi-Diffuse Radio interference filter (single circuit) two lamp ❑MW26 Max Wattage label, 26W ❑MW32 Max Wattage label, 32W ❑SYL1 Osram Sylvania Electronic Ballast (available only for standard EB option) DM Electronic Analog Dimming Ballast to 3%, 4-wire, 0-10V (120-277V) (Specify wattage on two lamp housing) ❑ECDM7,9 Lutron EcoSystem or 3-wire line voltage dimming ballast (120-277V). Dims to 5%. ❑HDM4 Lutron Hi-Lume® Dimming Ballast to 1% 3-wire (specify voltage and wattage) ❑2DM4 Lutron Tu-Wire® Dimming Ballast to 1% 3-wire (specify voltage and wattage) ❑7DM Advance Mark 7® Dimming Ballast to 5% 4-wire, 0-10V analog (120V thru 277V) (specify voltage and wattage) ❑XDM Advance Mark 10® Dimming Ballast to 5% 2-wire, line voltage ❑SMT Philips Advance SmartMate® ballast ❑CDN Canadian Electrical code compliant ballast disconnect ❑CDN 347V10 Canadian Electrical code compliant ballast disconnect D IS ❑RLF6CFH132EB 6" (1) 26/32/42W Triple tube, multi-volt electronic ballast (120-277V) ❑RLF6CFH226EB6 6" (2) 26W Quad, multi-volt electronic ballast (120-277V) A Division of Hubbell Lighting, Inc. 5-3/4" Specify lamp wattage, type, and Kelvin temperature. Prescolite Retrofit Downlights utilize the same award winning w/FT2 optics as the standard LiteFrame products. HOUSING 2-1/2"* 3-3/4"* 4-1/4" INSTALLATION: All components are made from quality die cast aluminum or galvaneal steel. Prewired J-box with snap-on cover for easy access. Vented at lamp tip and socket for maximum light output. Same housing accommodates downlight, wall wash downlight, and lensed downlight reflectors. *6-1/4" *7-1/2" REFLECTOR OPTIONS - ACCESSORIES ❑CL ❑BLANK ❑LP____________ Regressed clear Lens Clear Alzak -wattage= 26, 32, 42 ❑PL ❑CG -type= Q4 (Quad 4-pin); Regressed prismatic lens Champagne T4 (Triple 4-pin) ❑DL Gold Alzak -temp= 27K, 30K, 35K, Regressed diffuse lens 41K (Kelvin) ❑PW ❑FL Pewter Alzak ❑RWD62 Regressed fresnel lens Retrofit Wide Diameter ❑WE Housing Kit (6") ❑WT Wheat Alzak White Flange (Alzak only) ❑FSDFI ❑LW Fuse kit for field ❑TRG Light installation Trim Ring Gasket (Factory Wheat Alzak installed) ❑BB8 2 Black baffle (with clear Alzak ❑WF Wide Flange upper reflector) ❑WB8 1 Available for Osram Sylvania Quick 60+® Limited White baffle (with clear Alzak Warranty when used with Osram lamp(s). See www. upper reflector) prescolite.com for details. LENS SPLAY 2 See Housing Capatibility Guide for Hole Diameter 8 Compatibility on page 2 COLOR OPTIONS 3 Specify for lensed trims only (splay color option) ❑Blank 4 Not available for 42W Painted White 5 Use 6CFH1 reflector ❑CR 6 Use 6CFH reflector Clear Alzak ❑CG Champagne Gold Alzak ❑PW Pewter Alzak ❑WE Wheat Alzak ❑LW Light Wheat Alzak For 32W specify RLF8CFH232EB housing; for 42W specify RLF8CFH242EB housing, then add ECDM dimming option suffix 7 8 Not available with lensed trims For 26W or 32W specify RLF8CFH132EB housing; for 42W specify RLF8CFH142EB housing, then add ECDM dimming option suffix 9 10 Dimming option not available for 347V In a continuing effort to offer the best product possible we reserve the right to change, without notice, specifications or materials that in our opinion will not alter the function of the product. Web: www.prescolite.com • Tech Support: (888) 777-4832 RTF-001 PHOTOMETRIC DATA LiteFrame® - 6" Horizontal Triple Tube Open Retrofit Downlight - RLF6CFH132 Series BALLAST DATA 26W Triple 32W Triple 42W Triple 120V277V347V120V277V347V120V277V347V Total System Watts 292931363636464650 Input Current (Amps) 0.240.110.090.310.130.110.380.170.15 Input Frequency in Hz50/6050/6050/6050/6050/6050/6050/6050/6050/60 Power Factor <.98<.98<.95<.98<.98<.95<.98<.98<.95 Ballast Factor <1.1<1.1<1.02 <.98<.98<.98<.98<.98<1.0 Total Harmonic Distortion <10%<10%<10%<10%<10%<10%<10%<10%<10% LAMP DATA Rated Lumens 1710 2400 06/11/08 75 Efficacy (LPW) DATE:66 LUMINANCE DATA IN CANDELA/SQ. METER Angle in Average Average Average Vertical 0° 90° 180° 45° 45652 4067445315 55° 33290 2361531105 65° 6495 38127342 75° 692 692692 85° 685 0 0 3200 76 12,000 12,000 82 82 Min. Starting Temp. 32°F 32°F VANIA BS E tory RLF6CFH132EB/6CFH1 Clear ating ences Lamp: 1-CF32DT/E/IN/SYLVANIA and actual c, 120V, Spacing Criteria: 32°F Alzak Reflector U FH1 Rated Life 12,000 IGHT Stainless Steel w/ 3200 Alloy FLECTOR CRI 82 ED 26W Triple 32W Triple 42W Triple 0°=1.5 60˚ 60º 500 500 45º 45˚ 750 750 0˚ 0º ETER LEGEND: 0-deg: 90-deg: 15˚ 15º 30˚ 30º Test No. 3107 Checked 45° 90° N 75˚ 75º 250 250 0° 0 630630630 5 627625623 10623621622 15633623631 20722650634 25748678645 30711665648 35642630625 40605582573 45541523482 50447446360 55320298227 60179142109 65463927 70 888 75 333 80 211 85 110 90 000 Assumptions: 1. Ceiling 80% Wall 50% Floor 20% 2. 4 Luminaires evenly spaced in the center of the room. 3. The room is square and has a width and length equal to twice the lamp spacing (LS). 4. RCR is Room Cavity Ratio. 5. Dirt and Lumen Depreciation Factors are 1.0. 6. Ballast Factor is 1.0 for ballasted fixtures. TI Angle 90˚ 90º 69.3 % EG 180-DEG .5 1.6 CANDLEPOWER SUMMARY CANDLEPOWER DISTRIBUTION 60 181 314 400 405 250 50 4 0 %FIXT 33.4 57.4 96.7 100.0 0.0 100.0 69.3% CO N .0 30 34 42 99 49 37 99 52 3 0 0 Efficiency: FLUX Test No. 3107 AVERAGE INITIAL FOOTCANDLES ON WORKPLANE ET POSITION PER LAMP. 90°=1.5 Note:Approved Use of horizontally-lamped open downlights with amalgam-based CFL lamps in air-handling plenums is not recommended because cool air flow over the lamps will result in reduced light output. Prescolite recommends vertical lamp downlights or use of the regressed lensed trim option for horizontal downlights in these applications to reduce this effect. Refer to Prescolite White Paper WP0003 at www. prescolite.com for more information. D IS Housing Compatibility Guide Ordering Guidelines Requires SD Housing Option All Standard Housings 6 inch min max 5-15/16 6-1/8 6-1/8 6-1/2 Dimensions shown are for the diameter of the frame flange at it's narrowest point LS (Feet) (Footcandles) RCR1 RCR3 RCR7 7.0 37 29 20 8.0 28 23 15 9.0 22 18 12 10.0 1814 10 11.0 1512 8 12.0 1310 7 13.0 119 6 14.0 97 5 15.0 86 4 Test No. 3107 COEFFICIENTS OF UTILIZATION 80% 1 2 3 4 5 6 7 8 9 10 Zonal Cavity Method % Effective Ceiling Cavity Reflectance Room Cavity Ratio Rated Watts 70% 50%30%10% 20% Effective Floor Cavity Reflectance % Wall Reflectance 70 5030 10 7050 30 10 .77 .75 .73 .71 .76 .73 .71 .69 .72 .67 .63 .60 .70 .66 .62 .59 .66 .60 .55 .52 .65 .59 .55 .51 .61 .54 .49 .45 .60 .53 .48 .44 .57 .49 .43 .39 .55 .48 .43 .39 .52 .44 .38 .34 .51 .43 .38 .34 .49 .40 .34 .31 .47 .39 .34 .30 .45 .37 .31 .27 .44 .36 .31 .27 .42 .33 .28 .25 .41 .33 .28 .24 .40 .31 .26 .22 .39 .30 .26 .22 LF6CFH132EB/6CFH1 50 3010 .70 .69 .67 .63 .61 .58 .57 .53 .50 .51 .47 .44 .47 .42 .39 .42 .38 .34 .38 .34 .30 .35 .30 .27 .32 .28 .24 .30 .25 .22 5030 10 50 3010 .68 .66 .65 .65 .64 .63 .61 .59 .57 .59 .57 .56 .55 .52 .50 .54 .51 .49 .50 .46 .43 .49 .45 .43 .45 .41 .38 .44 .41 .38 .41 .37 .34 .40 .36 .33 .37 .33 .30 .37 .33 .30 .34 .30 .27 .34 .30 .27 .32 .27 .24 .31 .27 .24 .29 .25 .22 .29 .25 .22 Test No. 3107 NOTES Refer to standard spec sheets for photometric data for other reflector options. Refer to www.prescolite.com for additional photometric tests (IES Files). When ordering a sloped ceiling adapter, specify the degree of slope in 5° increments, max. of 35°. For a more precise degree or wet ceiling applications, please contact factory. Sloped ceiling adapter and housing must be installed at the same time prior to finish ceiling installation. Web: www.prescolite.com • Tech Support: (888) 777-4832 701 Millennium Blvd., • Greenville, SC 29607 U.S.A. • Phone (864) 678-1000 Copyright ©2013 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved Specifications subject to change without notice. • Printed in U.S.A. • RTF-001 • 6/20/13 PHOTOMETRIC DATA LiteFrame® - 6" Horizontal Quad Tube Open Retrofit Downlights - RLF6CFH Series BALLAST DATA 26W Quad 120V277V347V Total System Watts 51 51 57 Input Current (Amps) 0.43 0.19 0.17 Input Frequency in Hz 50/60 50/60 50/60 Power Factor <.99 <.99 <.95 Ballast Factor <1.0<1.0<.98 Total Harmonic Distortion <10% <10% <10% LAMP DATA 26W Quad Rated Lumens 1710 Efficacy (LPW) 66 Rated Life 12,000 CRI 82 ED Rated Watts LUMINANCE DATA IN CANDELA/SQ. METER Angle in Average Average Average Vertical 0° 45° 90° 45° 37973 3687637889 55° 36410 4067634850 65° 26544 2541423155 75° 922 922692 85° 685 685 685 U Min. Starting Temp. 32°F DATE: 01/11/08 Assumptions: 1. Ceiling 80% Wall 50% Floor 20% 2. 4 Luminaires evenly spaced in the center of the room. 3. The room is square and has a width and length equal to twice the lamp spacing (LS). 4. RCR is Room Cavity Ratio. 5. Dirt and Lumen Depreciation Factors are 1.0. 6. Ballast Factor is 1.0 for ballasted fixtures. N RLF6CFH226EB/6CFH Clear Alzak Reflector LAMP. FLUX CANDLEPOWER DISTRIBUTION Angle 90˚ 90º 75˚ 75º 300 300 60˚ 60º 600 600 45˚ 45º 2.1 % 0-DEG 1.2 900 900 LEGEND: 0-deg: 90-deg: 15˚ 15º 90° 180° 30˚ 30º 0 806806806 5 806800812 10789779793 15767756777 20742729750 25704686705 30648649640 35594580584 40509494514 45450437449 50405414385 55350391335 60263275221 65188180164 70261611 75 443 80 221 85 111 90 000 D IS 0˚ 0º 0° CO N %FIXT 34.2 54.3 91.2 100.0 0.0 100.0 CANDLEPOWER SUMMARY Test No. 3106 LS (Feet) (Footcandles) RCR1 RCR3 RCR7 7.0 39 31 20 8.0 30 24 15 9.0 24 19 12 10.0 1915 10 11.0 1612 8 12.0 1310 7 13.0 119 6 14.0 108 5 15.0 97 4 TI Lamp: 2-CF26DD/E/827 SYLVANIA Spacing Criteria: ctual 0°=1.2 0.2V, 90°=1.2 SITON Efficiency: 52.1% 76 216 318 358 345 313 152 5 1 Test No. 3106 AVERAGE INITIAL FOOTCANDLES ON WORKPLANE Stainless Steel w/ 3002 Alloy OR @ 93.1% Reflectance Test No. 3106 COEFFICIENTS OF UTILIZATION 80% 1 2 3 4 5 6 7 8 9 10 Zonal Cavity Method % Effective Ceiling Cavity Reflectance Room Cavity Ratio 70% 50%30%10% 20% Effective Floor Cavity Reflectance % Wall Reflectance 70 5030 10 7050 30 10 .58 .56 .54 .53 .57 .55 .53 .52 .53 .50 .47 .44 .52 .49 .46 .44 .49 .44 .41 .38 .48 .44 .40 .37 .45 .40 .36 .33 .44 .39 .35 .32 .42 .36 .31 .28 .41 .35 .31 .28 .39 .32 .28 .25 .38 .32 .28 .25 .36 .29 .25 .22 .35 .29 .25 .22 .34 .27 .23 .20 .33 .27 .23 .20 .31 .25 .21 .18 .31 .24 .21 .18 .29 .23 .19 .16 .29 .23 .19 .16 RLF6CFH226EB/6CFH 50 3010 .53 .51 .50 .47 .45 .43 .42 .39 .37 .38 .34 .32 .34 .31 .28 .31 .27 .25 .28 .25 .22 .26 .22 .20 .24 .20 .18 .22 .19 .16 5030 10 50 3010 .51 .50 .49 .49 .48 .47 .45 .44 .42 .44 .42 .41 .41 .38 .36 .39 .37 .36 .37 .34 .31 .36 .33 .31 .33 .30 .28 .32 .29 .27 .30 .27 .24 .29 .26 .24 .28 .24 .22 .27 .24 .22 .25 .22 .20 .25 .22 .20 .23 .20 .18 .23 .20 .18 .22 .18 .16 .21 .18 .16 Test No. 3106 NOTES Refer to standard spec sheets for photometric data for other reflector options. Refer to www.prescolite.com for additional photometric tests (IES Files). When ordering a sloped ceiling adapter, specify the degree of slope in 5° increments, max. of 35°. For a more precise degree or wet ceiling applications, please contact factory. Sloped ceiling adapter and housing must be installed at the same time prior to finish ceiling installation. Note: Use of horizontally-lamped open downlights with amalgam-based CFL lamps in air-handling plenums is not recommended because cool air flow over the lamps will result in reduced light output. Prescolite recommends vertical lamp downlights or use of the regressed lensed trim option for horizontal downlights in these applications to reduce this effect. Refer to Prescolite White Paper WP0003 at www.prescolite.com for more information. Web: www.prescolite.com • Tech Support: (888) 777-4832 701 Millennium Blvd., • Greenville, SC 29607 U.S.A. • Phone (864) 678-1000 Copyright ©2013 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved Specifications subject to change without notice. • Printed in U.S.A. • RTF-001 • 6/20/13