6" Horizontal
Compact Fluorescent
Open Retrofit Downlight
DATE:TYPE:
FIRM NAME:
PROJECT:
RLF6CFH
One 26W, 32W, or 42W
Triple Tube, 4-pin lamp or
Ceiling Cutout: See Guide
Maximum Ceiling Thickness: 1-1/2"
For conversion to millimeters,
multiply inches by 25.4
Not to Scale
Two 26W Quad
120V-277V for 347V
APPLICATIONS:
SOCKET:
The RLF6CFH series offers horizontally lamped
compact fluorescent downlight fixtures designed
specifically to retrofit into ceilings with existing recessed downlight fixtures without the need to remove
the existing fixture. The multi-watt, multi-volt ballast
provides the abillity to change wattages by simply
changing the lamp. This luminaire is ideal for a wide
variety of medium to high ceiling applications including commercial, retail, hospitality, and design-build.
Injection molded socket(s) (vented).
ED
LAMP:
*12-3/4"
*15"
For triple tube fixtures use one (1) 26W
(GX24q-3 base), 32W (GX24q-3 base),
or 42W (GX24q-4 base) 4-pin triple
tube compact fluorescent lamp. For 26W
(G24Q-3 base) quad tube 4-pin compact
fluorecent lamps. Lamps furnished by others
or as option below.
HOUSING:
LABELS:
OPTICS:
CSA/US listed for damp locations. CSA
listed for wet locations with lensed trims.
Approved for through wiring (4 in, 4 out).
Non-IC type. Canadian required ballast
disconnect standard.
N
High purity aluminum, Alzak, iridescence suppressed,
semi-diffuse reflector. Self-trim standard. Painted
white self-trim (WT) available as option. Baffled units
standard with painted white self-trim.
U
All installation can be performed from
below the ceiling without removing existing
fixture.
REFLECTOR:
*Dimensions shown are for range of
adjustability
LAMP INCLUDED OPTION:
TI
BALLAST:
CO
N
One (1) class 'P' 120V-277V HPF compact flourescent electronic ballast for long life and quiet operation. All ballast options are equipped with end of
life protection. Contact technical support for 347V.
Accessible from below ceiling.
Order housing, reflector and accessories separately.
*7-7/8"
*9-3/4"
CATALOG NUMBER:
5
HOUSING OPTIONS
-
EXAMPLE: RLF6CFH132EB 6CFH1 LP32T30K
REFLECTOR
COLOR
REFLECTOR
❑SD2
❑6CFH1
Small Diameter Housing
6" Alzak Semi-Diffuse
❑FSDFA
one lamp
Fuse kit installed at factory
❑6CFH
❑RIF1
6" Alzak Semi-Diffuse
Radio interference filter (single circuit)
two lamp
❑MW26
Max Wattage label, 26W
❑MW32
Max Wattage label, 32W
❑SYL1
Osram Sylvania Electronic Ballast (available only for standard EB option)
DM
Electronic Analog Dimming Ballast to 3%, 4-wire, 0-10V (120-277V) (Specify
wattage on two lamp housing)
❑ECDM7,9
Lutron EcoSystem or 3-wire line voltage dimming ballast (120-277V). Dims
to 5%.
❑HDM4
Lutron Hi-Lume® Dimming Ballast to 1% 3-wire (specify voltage and wattage)
❑2DM4
Lutron Tu-Wire® Dimming Ballast to 1% 3-wire (specify voltage and wattage)
❑7DM
Advance Mark 7® Dimming Ballast to 5% 4-wire, 0-10V analog (120V thru
277V) (specify voltage and wattage)
❑XDM
Advance Mark 10® Dimming Ballast to 5% 2-wire, line voltage
❑SMT
Philips Advance SmartMate® ballast
❑CDN
Canadian Electrical code compliant ballast disconnect
❑CDN 347V10
Canadian Electrical code compliant ballast disconnect
D
IS
❑RLF6CFH132EB
6" (1) 26/32/42W Triple
tube, multi-volt electronic ballast
(120-277V)
❑RLF6CFH226EB6
6" (2) 26W Quad, multi-volt electronic ballast (120-277V)
A Division of Hubbell Lighting, Inc.
5-3/4"
Specify lamp wattage, type, and Kelvin
temperature.
Prescolite Retrofit Downlights utilize the same award
winning w/FT2 optics as the standard LiteFrame
products.
HOUSING
2-1/2"*
3-3/4"*
4-1/4"
INSTALLATION:
All components are made from quality die cast
aluminum or galvaneal steel. Prewired J-box with
snap-on cover for easy access. Vented at lamp tip
and socket for maximum light output. Same housing
accommodates downlight, wall wash downlight, and
lensed downlight reflectors.
*6-1/4"
*7-1/2"
REFLECTOR
OPTIONS
-
ACCESSORIES
❑CL
❑BLANK
❑LP____________
Regressed clear Lens
Clear Alzak
-wattage= 26, 32, 42
❑PL
❑CG
-type= Q4 (Quad 4-pin);
Regressed prismatic lens
Champagne
T4 (Triple 4-pin)
❑DL
Gold Alzak
-temp= 27K, 30K, 35K,
Regressed diffuse lens
41K (Kelvin)
❑PW
❑FL
Pewter Alzak
❑RWD62
Regressed
fresnel
lens
Retrofit Wide Diameter
❑WE
Housing Kit (6")
❑WT
Wheat Alzak
White Flange (Alzak only) ❑FSDFI
❑LW
Fuse kit for field
❑TRG
Light
installation
Trim Ring Gasket (Factory
Wheat Alzak
installed)
❑BB8
2
Black baffle (with clear Alzak ❑WF
Wide Flange
upper reflector)
❑WB8
1
Available for Osram Sylvania Quick 60+® Limited
White baffle (with clear Alzak
Warranty when used with Osram lamp(s). See www.
upper reflector)
prescolite.com for details.
LENS SPLAY
2
See Housing Capatibility Guide for Hole Diameter
8
Compatibility on page 2
COLOR OPTIONS
3
Specify for lensed trims only (splay color option)
❑Blank
4
Not available for 42W
Painted White
5
Use 6CFH1 reflector
❑CR
6
Use 6CFH reflector
Clear Alzak
❑CG
Champagne Gold Alzak
❑PW
Pewter Alzak
❑WE
Wheat Alzak
❑LW
Light Wheat Alzak
For 32W specify RLF8CFH232EB housing; for 42W
specify RLF8CFH242EB housing, then add ECDM
dimming option suffix
7
8
Not available with lensed trims
For 26W or 32W specify RLF8CFH132EB housing; for
42W specify RLF8CFH142EB housing, then add ECDM
dimming option suffix
9
10
Dimming option not available for 347V
In a continuing effort to offer the best product possible we reserve the right to change, without
notice, specifications or materials that in our opinion will not alter the function of the product.
Web: www.prescolite.com
•
Tech Support: (888) 777-4832
RTF-001
PHOTOMETRIC DATA
LiteFrame® - 6" Horizontal Triple Tube
Open Retrofit Downlight - RLF6CFH132 Series
BALLAST DATA
26W Triple
32W Triple
42W Triple
120V277V347V120V277V347V120V277V347V
Total System Watts
292931363636464650
Input Current (Amps)
0.240.110.090.310.130.110.380.170.15
Input Frequency in Hz50/6050/6050/6050/6050/6050/6050/6050/6050/60
Power Factor
<.98<.98<.95<.98<.98<.95<.98<.98<.95
Ballast Factor
<1.1<1.1<1.02
<.98<.98<.98<.98<.98<1.0
Total Harmonic Distortion
<10%<10%<10%<10%<10%<10%<10%<10%<10%
LAMP DATA
Rated Lumens
1710
2400
06/11/08 75
Efficacy (LPW) DATE:66
LUMINANCE DATA IN CANDELA/SQ. METER
Angle in Average
Average Average
Vertical
0° 90°
180°
45°
45652 4067445315
55°
33290 2361531105
65° 6495 38127342
75° 692 692692
85° 685
0
0
3200
76
12,000
12,000
82
82
Min. Starting Temp. 32°F
32°F
VANIA
BS
E
tory
RLF6CFH132EB/6CFH1 Clear
ating
ences
Lamp: 1-CF32DT/E/IN/SYLVANIA
and actual
c, 120V, Spacing Criteria:
32°F
Alzak Reflector
U
FH1
Rated Life
12,000
IGHT Stainless Steel w/ 3200 Alloy
FLECTOR CRI
82
ED
26W Triple 32W Triple 42W Triple
0°=1.5
60˚
60º
500
500
45º
45˚
750
750
0˚
0º
ETER
LEGEND:
0-deg:
90-deg:
15˚
15º
30˚
30º
Test No. 3107
Checked
45°
90°
N
75˚
75º
250
250
0°
0 630630630
5 627625623
10623621622
15633623631
20722650634
25748678645
30711665648
35642630625
40605582573
45541523482
50447446360
55320298227
60179142109
65463927
70
888
75
333
80
211
85
110
90
000
Assumptions:
1. Ceiling 80% Wall 50% Floor 20%
2. 4 Luminaires evenly spaced in the center of the room.
3. The room is square and has a width and length equal to twice the
lamp spacing (LS).
4. RCR is Room Cavity Ratio.
5. Dirt and Lumen Depreciation Factors are 1.0.
6. Ballast Factor is 1.0 for ballasted fixtures.
TI
Angle
90˚
90º
69.3 %
EG 180-DEG
.5
1.6
CANDLEPOWER
SUMMARY
CANDLEPOWER
DISTRIBUTION
60
181
314
400
405
250
50
4
0
%FIXT
33.4
57.4
96.7
100.0
0.0
100.0
69.3%
CO
N
.0
30
34
42
99
49
37
99
52
3
0
0
Efficiency:
FLUX
Test No. 3107
AVERAGE INITIAL FOOTCANDLES ON WORKPLANE
ET POSITION
PER LAMP.
90°=1.5
Note:Approved
Use of horizontally-lamped open downlights with amalgam-based CFL lamps in air-handling
plenums is not recommended because cool air flow over the lamps will result in reduced light output.
Prescolite recommends vertical lamp downlights or use of the regressed lensed trim option for horizontal
downlights in these applications to reduce this effect. Refer to Prescolite White Paper WP0003 at www.
prescolite.com for more information.
D
IS
Housing Compatibility Guide
Ordering
Guidelines
Requires SD Housing
Option
All Standard Housings
6 inch
min
max
5-15/16
6-1/8
6-1/8
6-1/2
Dimensions shown are for the
diameter of the frame flange at it's
narrowest point
LS (Feet)
(Footcandles)
RCR1 RCR3 RCR7
7.0
37
29
20
8.0
28
23
15
9.0
22
18
12
10.0 1814 10
11.0 1512 8
12.0 1310 7
13.0 119 6
14.0 97 5
15.0 86 4
Test No. 3107
COEFFICIENTS OF UTILIZATION 80%
1
2
3
4
5
6
7
8
9
10
Zonal Cavity Method
% Effective Ceiling Cavity Reflectance
Room Cavity
Ratio
Rated Watts
70% 50%30%10%
20% Effective Floor Cavity Reflectance
% Wall Reflectance
70 5030 10 7050 30 10
.77 .75 .73 .71 .76 .73 .71 .69
.72 .67 .63 .60 .70 .66 .62 .59
.66 .60 .55 .52 .65 .59 .55 .51
.61 .54 .49 .45 .60 .53 .48 .44
.57 .49 .43 .39 .55 .48 .43 .39
.52 .44 .38 .34 .51 .43 .38 .34
.49 .40 .34 .31 .47 .39 .34 .30
.45 .37 .31 .27 .44 .36 .31 .27
.42 .33 .28 .25 .41 .33 .28 .24
.40 .31 .26 .22 .39 .30 .26 .22
LF6CFH132EB/6CFH1
50 3010
.70 .69 .67
.63 .61 .58
.57 .53 .50
.51 .47 .44
.47 .42 .39
.42 .38 .34
.38 .34 .30
.35 .30 .27
.32 .28 .24
.30 .25 .22
5030 10 50 3010
.68 .66 .65 .65 .64 .63
.61 .59 .57 .59 .57 .56
.55 .52 .50 .54 .51 .49
.50 .46 .43 .49 .45 .43
.45 .41 .38 .44 .41 .38
.41 .37 .34 .40 .36 .33
.37 .33 .30 .37 .33 .30
.34 .30 .27 .34 .30 .27
.32 .27 .24 .31 .27 .24
.29 .25 .22 .29 .25 .22
Test No. 3107
NOTES
Refer to standard spec sheets for photometric data for other reflector
options.
Refer to www.prescolite.com for additional photometric tests (IES Files).
When ordering a sloped ceiling adapter, specify the degree of slope in 5°
increments, max. of 35°. For a more precise degree or wet ceiling applications, please contact factory. Sloped ceiling adapter and housing must be
installed at the same time prior to finish ceiling installation.
Web: www.prescolite.com • Tech Support: (888) 777-4832
701 Millennium Blvd., • Greenville, SC 29607 U.S.A. • Phone (864) 678-1000
Copyright ©2013 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved
Specifications subject to change without notice. • Printed in U.S.A. • RTF-001 • 6/20/13
PHOTOMETRIC DATA
LiteFrame® - 6" Horizontal Quad Tube
Open Retrofit Downlights - RLF6CFH Series
BALLAST DATA
26W Quad
120V277V347V
Total System Watts
51
51
57
Input Current (Amps)
0.43
0.19
0.17
Input Frequency in Hz
50/60
50/60
50/60
Power Factor <.99
<.99
<.95
Ballast Factor
<1.0<1.0<.98
Total Harmonic Distortion <10%
<10%
<10%
LAMP DATA
26W Quad
Rated Lumens
1710
Efficacy (LPW)
66
Rated Life
12,000
CRI
82
ED
Rated Watts
LUMINANCE DATA IN CANDELA/SQ. METER
Angle in Average
Average Average
Vertical
0° 45°
90°
45°
37973 3687637889
55°
36410 4067634850
65°
26544 2541423155
75° 922 922692
85° 685
685
685
U
Min. Starting Temp. 32°F
DATE: 01/11/08
Assumptions:
1. Ceiling 80% Wall 50% Floor 20%
2. 4 Luminaires evenly spaced in the center of the room.
3. The room is square and has a width and length equal to twice the
lamp spacing (LS).
4. RCR is Room Cavity Ratio.
5. Dirt and Lumen Depreciation Factors are 1.0.
6. Ballast Factor is 1.0 for ballasted fixtures.
N
RLF6CFH226EB/6CFH Clear Alzak Reflector
LAMP.
FLUX
CANDLEPOWER
DISTRIBUTION
Angle
90˚
90º
75˚
75º
300
300
60˚
60º
600
600
45˚
45º
2.1 %
0-DEG
1.2
900
900
LEGEND:
0-deg:
90-deg:
15˚
15º
90°
180°
30˚
30º
0 806806806
5 806800812
10789779793
15767756777
20742729750
25704686705
30648649640
35594580584
40509494514
45450437449
50405414385
55350391335
60263275221
65188180164
70261611
75
443
80
221
85
111
90
000
D
IS
0˚
0º
0°
CO
N
%FIXT
34.2
54.3
91.2
100.0
0.0
100.0
CANDLEPOWER
SUMMARY
Test No. 3106
LS (Feet)
(Footcandles)
RCR1 RCR3 RCR7
7.0
39
31
20
8.0
30
24
15
9.0
24
19
12
10.0 1915 10
11.0 1612 8
12.0 1310 7
13.0 119 6
14.0 108 5
15.0 97 4
TI
Lamp: 2-CF26DD/E/827 SYLVANIA
Spacing Criteria:
ctual 0°=1.2
0.2V, 90°=1.2
SITON Efficiency: 52.1%
76
216
318
358
345
313
152
5
1
Test No. 3106
AVERAGE INITIAL FOOTCANDLES ON WORKPLANE
Stainless Steel w/ 3002 Alloy
OR @ 93.1% Reflectance
Test No. 3106
COEFFICIENTS OF UTILIZATION 80%
1
2
3
4
5
6
7
8
9
10
Zonal Cavity Method
% Effective Ceiling Cavity Reflectance
Room Cavity
Ratio
70% 50%30%10%
20% Effective Floor Cavity Reflectance
% Wall Reflectance
70 5030 10 7050 30 10
.58 .56 .54 .53 .57 .55 .53 .52
.53 .50 .47 .44 .52 .49 .46 .44
.49 .44 .41 .38 .48 .44 .40 .37
.45 .40 .36 .33 .44 .39 .35 .32
.42 .36 .31 .28 .41 .35 .31 .28
.39 .32 .28 .25 .38 .32 .28 .25
.36 .29 .25 .22 .35 .29 .25 .22
.34 .27 .23 .20 .33 .27 .23 .20
.31 .25 .21 .18 .31 .24 .21 .18
.29 .23 .19 .16 .29 .23 .19 .16
RLF6CFH226EB/6CFH
50 3010
.53 .51 .50
.47 .45 .43
.42 .39 .37
.38 .34 .32
.34 .31 .28
.31 .27 .25
.28 .25 .22
.26 .22 .20
.24 .20 .18
.22 .19 .16
5030 10 50 3010
.51 .50 .49 .49 .48 .47
.45 .44 .42 .44 .42 .41
.41 .38 .36 .39 .37 .36
.37 .34 .31 .36 .33 .31
.33 .30 .28 .32 .29 .27
.30 .27 .24 .29 .26 .24
.28 .24 .22 .27 .24 .22
.25 .22 .20 .25 .22 .20
.23 .20 .18 .23 .20 .18
.22 .18 .16 .21 .18 .16
Test No. 3106
NOTES
Refer to standard spec sheets for photometric data for other reflector options.
Refer to www.prescolite.com for additional photometric tests (IES Files).
When ordering a sloped ceiling adapter, specify the degree of slope in 5°
increments, max. of 35°. For a more precise degree or wet ceiling applications,
please contact factory. Sloped ceiling adapter and housing must be installed
at the same time prior to finish ceiling installation.
Note: Use of horizontally-lamped open downlights with amalgam-based CFL
lamps in air-handling plenums is not recommended because cool air flow over
the lamps will result in reduced light output. Prescolite recommends vertical
lamp downlights or use of the regressed lensed trim option for horizontal
downlights in these applications to reduce this effect. Refer to Prescolite White
Paper WP0003 at www.prescolite.com for more information.
Web: www.prescolite.com • Tech Support: (888) 777-4832
701 Millennium Blvd., • Greenville, SC 29607 U.S.A. • Phone (864) 678-1000
Copyright ©2013 Prescolite, Inc., a division of Hubbell Lighting, Inc. All Rights Reserved
Specifications subject to change without notice. • Printed in U.S.A. • RTF-001 • 6/20/13