0 -‐ 10V Dimming for Xeleum`s Architectural Troffers

advertisement
XCV-­‐100 Installa(on Guide 0 -­‐ 10V Dimming for Xeleum’s Architectural Troffers 1 Xeleum Ligh(ng, LLC. 333 North Bedford Rd. Mount Kisco, NY 10549 * Phone 914 773 6250 * Fax 914 241 3825 * www.xeleum.com This XCV-­‐100 controller was specifically designed to seamlessly integrate with the Xeleum Iridium Series Troffers. Each XCV-­‐100 can control up to six (6) Troffers (1’X4’, 2’X2’, or 2’X4). Please read these instruc(ons carefully, and keep it for future reference. PART LIST (Included with each XCV-­‐100) (1) XCV-­‐100 (5) 0 – 10V Harnesses TOOLS NEEDED Small Flat Blade Screwdriver Ladder WARNING: Turn power off at circuit breaker or fuse box. Do not rely on a wall switch alone to turn off power. Failure to do so may cause a shocking hazard and damage this electronic fixture! 2 The XCV-­‐100 Controller is en(rely low voltage. If you are at all uncomfortable on a ladder, or with the installa(on of basic wiring, consult a local licensed electrician or electrical contractor. These instruc(ons assume the Troffers have already been installed and are working properly. INSTALLATION GUIDE -­‐ WARNING: RISK OF ELECTRIC SHOCK -­‐ AVERTISSEMENT: RISQUE DE CHOC ELETRIQUE -­‐ ACCESS ABOVE CEILING REQUIRED -­‐ ACCES REQUIS AU-­‐DESSUS DU PLAFOND -­‐ FOR DRY LOCATIONS ONLY -­‐ POUR EMPLACEMENT SECS SEULEMENT Step #1 -­‐ Unpack the XCV-­‐100 Kit. Ensure it has arrived undamaged. -­‐ Remove the wire (es from around the five provided sensor harnesses. 3 Grey Purple Step #2 As a general rule the XCV-­‐100 should be afached to the fixture closest to the incoming 0-­‐10V supply line (Purple and Grey wires). The XCV-­‐100 comes with 2-­‐sided adhesive tape on the back. Remove the peal off paper from the back of the tape and press it on the back of the troffer, close enough to the driver to ensure that the wires from the XCV-­‐100 Will reach the connectors on the driver. Step #3 Once the XCV-­‐100 has been stuck onto the back of the first troffer, route the 0 -­‐ 10V dimming lines (Purple and Grey wires) to the XCV-­‐100 and insert them into the push-­‐in connectors. The Purple wire should go into the hole labeled “0 – 10V”, and the Grey wire should be pushed into the hole labeled “GND”. Depending on the gauge of the wire you may find it easier to push the bufon just above the holes during the inser(on of the wires. You MUST push and hold down the bufon just above the holes to remove the wires. Step #4 Once the 0-­‐10V dimming line has been properly connected to the push-­‐in connectors on the XCV-­‐100, take the black connector on the the XCV-­‐100 (with red, white and black wires) and insert it into one of the black connectors protruding from the driver (either connector on the driver will work). 4 Step #5 Using one of the 0 – 10V harnesses provided with the XCV-­‐100 kit, plug one end into the remaining open black connector on the driver of the fixture with the XCV-­‐100 installed. Connect the other end of the harness to one of the black connectors on the driver of the next fixture. Con(nue this process in a daisy-­‐chain fashion un(l all of the fixtures within a space are linked (up to six fixtures). Note: If addi(onal length Supplied is needed on the harnesses, Harnesses these wires can be spliced Red/Blk/Wht XCV-­‐100 together in the field. They are low voltage. Just make Xeleum sure the wire colors are Iridium properly aligned and Troffer insulate the splices with electrical tape. 0-­‐10V Dimmer Step #6 There is a switch on the side of the XCV-­‐100. For most installa(ons with a standard wall dimmer the switch should be lel in its default or “Source” posi(on. In situa(ons in which the incoming 0 – 10V dimming is controlled by an advanced Building Management System or even some Home Management Systems, the switch on the XCV-­‐100 should be moved to the “Sink” posi(on. Switch 5 Step #7 Your new XCV-­‐100 0 – 10V System is now ready for opera(on. Turn the power back on at the circuit breaker or fuse box. Operate the wall dimmer and make sure all installed fixtures are dimming properly. If all the fixtures are not dimming properly, check the electrical connec(ons aler re-­‐securing the power at the circuit breaker or fuse box. DIMMER NOTE: To ensure long-­‐life and proper opera(on of the XCV-­‐100 and fixtures hooked up to these units, make sure to only use dimmers that are LED compa(ble. Specifically, 0-­‐10V current sink dimming. If in doubt, consult your local electrician. 6 FCC Statement This device complies with Part 15 of the FCC rules. Opera(on is subject to the following two condi(ons: (1)  Device may not cause harmful interference (2)  (2) the device must accept any interference that may cause undesired opera(on. FCC Note: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifica(ons to the equipment. Such modifica(ons could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protec(on against harmful interference in a residen(al installa(on. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruc(on may cause harmful interference to radio communica(ons. However, there is no guarantee that interference will not occur in a par(cular installa(on. If this equipment does cause harmful interference to radio or television recep(on, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •  Reorient or relocate the receiving antenna •  Increase the separa(on between the equipment and the receiver •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected •  Consult the dealer or an experienced radio/TV technician for help 7 
Download