Installation Instructions for Siemens - Fire Safety U-MH-1G, U-MH, U-MH-1G and U-MHT Electronic Signal and U-MH-MCS, and U-MHT-MCS Electronic Signal W/ Strobe (Selectable Candela / Sync/Non-Sync Strobe) IMPORTANT - All audible and visual signaling appliances must be installed in The Electronic Signal and the Strobe lights were only tested to the operating accordance with all applicable national and local fire alarm codes and any other required regulatory agency. voltage limits of 16v and 32v. Do Not apply 80% and 110% of these values for system operation. The Electronic Signal and the Strobe lights are designed for DC and FWR power sources. The Electronic Signal and the Strobe lights are for indoor use only, +32ºF to 120ºF (0ºC to 49ºC) with a maximum humidity of 85% RH. They can be either wall mounted or ceiling mounted. The Electronic Signal and the Strobe lights must be connected to a compatible The maximum number of 15 cd sync Strobes per circuit is 42. The maximum signal circuit with a steady current output and appropriate voltage. line impedance between any two adjacent Strobes to still remain in sync is 30 The Strobe lights is designed to operate as a synchronized strobe when ohms. Note: Do not exceed maximum recommended line impedance specified properly wired to a Model DSC Sync Control unit or a compatible source of for the Notification Appliance Circuit. Siemens Sync Protocol. When the Strobe light is connected to a conventional Field repair of these signals is not to be attempted. Malfunctioning units should notification circuit, it will flash at a 1 Hz rate but it will not be synchronized. be returned to the factory for repair or replacement. The Model U-MH-1G Series Electronic Audible Signal may be configured for As with all fire equipment periodic testing is required (Ref. NFPA 72). Signals steady or non-sync temporal operation. When selecting temporal pattern should be tested at least two times a year and more often if required by local output, the Electronic Audible Signal must be powered from a Non-Pulsing and/or state codes. Defective devices must be replaced immediately. Notification Appliance Circuit. See diagram at bottom of page for location of jumper for configuring Model U-MH-1G Series Electronic Signal for steady or temporal output. The Strobe lights can also be installed in systems needing synchronization (See Fig. 8). For synchronization a Model DSC Sync Control unit or a compatible source of Siemens Sync Protocol must be wired electrically before the strobes. For synchronization load requirements see Installation Instructions for the DSC Sync Control unit or compatible source of Siemens Sync. Protocol. Audible Specifications SOUND NOTE: Audible part of U-MH-MCS and U-MHT-MCS Electronic Signals are NOT for use in circuits needing synchronization and are NOT to be connected to a source of Siemens Sync Protocol. Jumper Location for Model U-MH-1G, U-MHT and U-MHT-MCS Steady ON=TEMPORAL OFF=STEADY NOTE: When Selecting Temporal Pattern, the Horn Must be Powered From a Non-Pulsing Notification Appliance Circuit. Temporal (U-UMHT series) UL REVERBERANT VOLTAGE RMS Special Application DC & FWR Current 16 11ma 79.2 24 18ma 82.4 32 26ma 83.8 16 9ma 75.9 24 16ma 77.7 32 26ma 79 dB @ 10 FT. Temporal Selector Jumper Note: The 3 pulse temporal pattern is to be used for evacuation use only. For visual specifications for strobe currents & intensities See page 5. An ISO Certified Company Made in the USA Siemens Building Technologies, Inc. 8 Fernwood Road Florham Park, New Jersey 07932 315-544988-4 PAGE 1 OF 6 4/30/04 Mounting Instructions Wiring Note: Individual wires (especially heavy gauge wire) should be bent at 90° before attaching to screw. Wiring should then carefully be pushed back into back box to minimize stress on the terminal block. (2) 6-32 x 1-3/4" Screws U-MH-1G or U-MH-1G ELECTRONIC SIGNAL (Fig. 1) 1. 2. 3. 4. For U-MH-1G Electronic Signal, configure Electronic Signal for temporal or steady tone. (see diagram on page 1) Connect wiring (see fig. 4). Mount the Electronic Signal to the single gang box with the two # 6-32 x 1-3/4" screws. Test unit for proper operation. Fig. 1 (U-MH-1G or U-MH-1G) (4) 6-32 x 5/8" Screws (2) 6-32 x 5/8" Screws U-MH or U-MHT ELECTRONIC SIGNAL (Fig 2) 1. 2. 3. 4. 5. 6. For U-MHT Electronic Signal, configure Electronic Signal for temporal or steady tone. (see diagram on page 1) Pull the wires from the outlet box through the large opening in the adapter plate. Mount the adapter plate to the electrical box using the appropriate screws provided. Making sure that the adapter plate is mounted in the upright position. (Note: When using a single gang outlet box make sure to use the holes labelled "single gang".) Connect wiring (see fig. 5). Mount the grill on to the adapter plate by first engaging the two slots in the bottom of the grille with the two tabs in the bottom of the adapter. Test unit for proper operation. U-MH-MCS, U-MHT-MCS ELECTRONIC SIGNAL/STROBE (Fig. 3) 1. 2. 3. 4. 5. 6. 7. 8. #6 x 1-1/4" Self Tapping Screw (2) 8-32 x 1/2" Screws OR OR Fig. 2 (U-MH or U-MHT) (4) 6-32 x 5/8" Screws For U-MHT-MCS Electronic Signal w/Strobe, configure Electronic Signal for temporal or steady tone. (see diagram on page 1) TIGHTEN SCREW UNTIL SNUG (2) 6-32 Move Strobe Candela Selection Switch to desired setting. DO NOT OVERTIGHTEN x 5/8" (see diagram page 5) Screws Place supplied hole plug (P/N 944276) in for hole for Strobe Candela Selection Switch. Pull the wires from the outlet box through the large (2) 8-32 OR opening in the adapter plate. x 1/2" OR #6 x 5/8" Mount the adapter plate to the electrical box using the Screws Self appropriate screws provided. Making sure that the adapter Tapping plate is mounted in the upright position. Screw (Note: When using a single gang outlet box make sure to use the holes labelled "single gang".) Configure and wire the U-MH-MCS or U-MHT-MCS for either single circuit or split audible/strobe operation (see fig. 6, fig. 7 or fig. 8). (Note: Split operation requires two separate notification circuits.) Fig. 3 (Note: Audible part of U-MH-MCS and U-MHT-MCS Electronic Signals are (U-MH-MCS or U-MHT-MCS) not for use in circuits needing synchronization and are not to be connected to source of Siemens Sync Protocol.) Supplied Hole Plug (P/N 944276) Mount the grille on to the adapter plate by first engaging the two Place Hole Plug in hole for Strobe Candela slots in the bottom of the grille with the two tabs in the bottom of the Selection Switch after moving Candela adapter plate. Then use the # 6 x 5/8" self tapping screw to attach Selection Switch to desired candela rating position the grill to the adapter plate. Test unit for proper operation. 315-544988-4 PAGE 2 OF 6 4/30/04 NOTE: Wiring Diagrams UNITS TO BE ONLY INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND LOCAL ELECTRICAL CODES. DO NOT LOOP WIRE, CUT WIRE RUN TO PROVIDE ELECTRICAL SUPERVISION Terminals are designed to accept no larger than 12 ga. wire. Wiring Diagram for Wiring Diagram for U-MH-1G or U-MH-1G Electronic Audible Signal U-MH or U-MHT Electronic Audible Signal (Non-Sync Circuit) (Non-Sync Circuit) Individual wires (especially heavy gauge wire) should be bent at 90° before attaching to screw. Wiring should then carefully be pushed back into back box to minimize stress on the terminal block. TO NEXT DEVICE OR EOL. FROM CONTROL PANEL OR PREVIOUS DEVICE AUDIBLE NOTIFICATION APPLIANCE CKT. ALARM POLARITY SHOWN FROM CONTROL PANEL OR PREVIOUS DEVICE AUDIBLE NOTIFICATION APPLIANCE CKT. Fig. 4 TO NEXT DEVICE OR EOL. ALARM POLARITY SHOWN Fig. 5 Wiring Diagram for U-MH-MCS or U-MHT-MCS Electronic Audible Signal w/Strobe When Signal and Non-Sync Strobe are Connected to Same Notification Appliance Circuit. LEAVE JUMPERS IN PLACE (STROBE AND AUDIBLE SIGNAL ARE TO OPERATE ON THE SAME CIRCUIT) Individual wires (especially heavy gauge wire) should be bent at 90° before attaching to screw. Wiring should then carefully be pushed back into back box to minimize stress on the terminal block. NOTE: STROBES MUST BE CONNECTED TO A NON-PULSING NOTIFICATION APPLIANCE CKT. FROM CONTROL PANEL OR PREVIOUS DEVICE TO NEXT DEVICE OR EOL. ALARM POLARITY SHOWN NOTIFICATION APPLIANCE CKT. NOTE: + - + - WHEN AUDIBLE SIGNAL AND STROBE ARE CONNECTED TO SAME NOTIFICATION APPLIANCE CIRCUIT, CURRENT RATING IS COMBINATION OF AUDIBLE SIGNAL AND STROBE CURRENT. Fig. 6 315-544988-4 PAGE 3 OF 6 4/30/04 Wiring Diagrams NOTE: UNITS TO BE ONLY INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND LOCAL ELECTRICAL CODES. DO NOT LOOP WIRE, CUT WIRE RUN TO PROVIDE ELECTRICAL SUPERVISION Terminals are designed to accept no larger than 12 ga. wire. Wiring Diagram for U-MH-MCS or U-MHT-MCS Electronic Audible Signal w/Strobe When Signal and Non-Sync Strobe are Connected to Two Separate Notification Appliance Circuits. CUT JUMPERS (AUDIBLE SIGNAL AND STROBE ON SEPARATE CIRCUITS) NOTE: STROBES MUST BE CONNECTED TO A NON-PULSING NOTIFICATION APPLIANCE CKT. FROM CONTROL PANEL OR PREVIOUS DEVICE STROBE NOTIFICATION APPLIANCE CKT. AUDIBLE NOTIFICATION APPLIANCE CKT. + + - TO NEXT DEVICE OR EOL. ALARM POLARITY SHOWN Fig. 7 + + - Individual wires (especially heavy gauge wire) should be bent at 90° before attaching to screw. Wiring should then carefully be pushed back into back box to minimize stress on the terminal block. Wiring Diagram for U-MH-MCS, U-MHT-MCS Electronic Audible Signal w/Strobe When Strobe is Connected to DSC Sync Control Module. From control panel steady (non-pulsing or pulsing) silenceable Notification Appliance Circuit or previous silenceable notification appliance. From control panel steady (non-pulsing) non-silenceable Notification Appliance Circuit (N.A.C.) or previous notification appliance. CUT JUMPERS (STROBE ON SYNC STROBE CIRCUIT) DSC 16-32 V DC or FWR 20ma NOTE: STROBES MUST BE CONNECTED TO A NON-PULSING NOTIFICATION APPLIANCE CKT. NOTE: Audible part of U-MH-MCS and UMHT-MCS Electronic Signals are not for use in circuits needing synchronization and are not to be connected to Model DSC Sync Control unit. SUPERVISED AND POWERED BY NON-SILENCEABLE N.A.C. FROM FIRE ALARM CONTROL UNIT. FROM CONTROL PANEL AUDIBLE N.A.C. OR PREVIOUS AUDIBLE DEVICE 315-544988-4 TO NEXT DEVICE OR EOL. Fig. 8 PAGE 4 OF 6 TO NEXT DEVICE OR EOL. 4/30/04 SPECIFICATIONS: Visual Signaling Appliance The Strobe Candela Selection Switch Setting determines current draw. Adjustment Switch Setting 15 30 75 110 Listed UL 1971 Output 15 cd 30 cd 75 cd 110 cd Light Output, on Axis 75 cd 75 cd 75 cd 110 cd Operating Voltage Range Limits Special Application 16 - 32V DC or FWR DC *Maximum Operating RMS Current FWR & DC FWR DC FWR DC FWR DC FWR 16V 91 mA 112 mA 120 mA 139 mA 218 mA 251 mA 315 mA 323 mA 24V 63 mA 82 mA 84 mA 107 mA 143 mA 182 mA 178 mA 234 mA 32V 54 mA 75 mA 64 mA 94 mA 16V Rated Peak Current FWR & 24V DC 32V 116 mA 142 mA 153 mA 183 mA 132 mA 264 mA 169 mA 272 mA 642 mA 668 mA 624 mA 652 mA 118 mA 278 mA 153 mA 298 mA 330 mA 668 mA 434 mA 636 mA 104 mA 664 mA 177 mA 668 mA 648 mA 682 mA 624 mA 666 mA Less than 840ma for 2 ms. Initial Inrush 1 Per Second Strobe Flash Rate 15 cd and 30 cd Strobe switch settings were tested for 75 cd. minimum on axis. ADA Minimum Frontal Light Output requirement is 75 cd. UL. 1971 Standard covers emergency signaling devices for the hearing impaired. These strobe lights were only tested to the operating voltage limits of 16v and 32v. Do Not apply 80% and 110% of these values for system operation. The maximum number of 15 cd sync strobes per circuit is 42. The maximum line impedance between any two adjacent strobes to still remain in sync is 30 ohms. Note: Do not exceed maximum recommended line impedance specified for the Notification Appliance Circuit. UL 1971 Visual Dispersion for Wall and Ceiling Mounting Minimum Candela Degrees -15 -30 -60 -75 -110 110 0 75 75 75 75 5 to 25 13.5 27 54 67.5 99 30 to 45 11.25 22.5 45 56.25 82.5 50 8.25 16.5 31 41.25 60.5 55 6.75 13.5 27 33.75 49.5 60 6 12 24 30 44 65 5.25 10.5 21 26.25 38.5 70 5.25 10.5 21 26.25 38.5 75 4.5 9 18 22.5 33 80 4.5 9 18 22.5 33 85 3.75 7.5 15 18.75 27.5 90 3.75 7.5 15 18.75 27.5 315-544988-4 Supplied Hole Plug (P/N 944276) Place Hole Plug in hole for Strobe Candela Selection Switch after moving Candela Selection Switch to desired candela rating position 30 candela 75 candela 15 candela 110 candela Strobe Candela Selection Switch Location PAGE 5 OF 6 Strobe Candela Selection Switch Settings Factory Set at 15 Candela 4/30/04 Siemens - 8 Fernwood Road, Florham Park, New Jersey 07932 An ISO Certified Company Made in the USA 315-544988-4 PAGE 6 OF 6 4/30/04