AS-24 SELECT-A-STROBE SERIES (FIELD SELECTABLE CANDELA) Features: • Designed to meet or exceed NFPA / ANSI Standards and ADA Accessibility Guidelines. • UL listed for Wall mounting. • Screw terminals capacity up to 12 AWG. • Universal mounting plate included with each unit. • Strobe with two field selectable settings 75 or 110 cd. • UL listed for fire protective service. • Polarized strobes with wide listed voltage ranges using filtered DC or unfiltered FWR input voltage. • Meets ADA guidelines for minimum one flash per/sec (1 Hz). • All models mount to 4" square, single gang, double gang, or octagon back box. Strobe with Universal Mounting Plate • 24 volt strobe models 75 or 110 candela intensity. • Tamper-proof candela selector switch. • Synchronization requires a Potter SM-3A Sync Module CALL FOR ADDITIONAL LISTINGS • Available in red only. Description: Selectable Candela Output: Potter's Select-a-Strobe series are designed to comply with the Americans with Disability Act (ADA) and meet UL standard 1971 requirements for emergency signaling devices for the hearing impaired. The AS-24 series Select-A-Strobe features a unique candela intensity field selector switch for switching the candela output from 75 or 110 cd. The strobe is polarized for connecting to supervised fire alarm circuits and is designed with a xenon flashtube. The strobe provides a candela intensity tamper-proof field selector switch for maximum performance. The AS24-75110R Select-A-Strobe can be synchronized by using the SM-3A sync module to comply with NFPA recommendations concerning photosensitive epilepsy when installing 2 or more visual appliances within the field of view. The strobe signals are listed for indoor use, wall mount, under UL 1971 standard. Tamper Proof Application: The AS24-75110R series strobes are recommended for use in areas such as; meeting rooms, schools, corridors, apartments, office buildings, restaurants, hotels, and any other application where effective visual warning is required by Federal, State, or local authority having jurisdiction. Wiring: *Polarity shown is with NAC activated Ordering Information: Part N umber 1430204 Model N umber AS24-75110R Input Voltage (VD C ) R eg . 24V D C /FWR 24 Strobe C andela 75 or 110 S yn c w / SM-3A Module Wall Mount X X WARNING: Conductor Size (AWG), Length and capacity should be taken into consideration prior to design and installation of these products, particularly in retrofit installations. Potter Electric Signal Company • 2081 Craig Road, St. Louis, MO, 63146-4161 • Phone: 800-325-3936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN U.S.A. MFG. #8850014 - REV A 08/02 PAGE 1 OF 2 AS-24 SELECT-A-STROBE SERIES (FIELD SELECTABLE CANDELA) Engineering Specifications: The Visual alarm indicating appliance shall be Potter model AS24-75110R or equivalent device. The strobe shall be listed under UL 1971 standard for signaling devices for the hearing impaired and shall be approved for fire protective service. The candela output shall be field selectable, having a dual setting of 75 cd or 110 cd output. The signaling strobe shall operate on 24VDC from a non-coded regulated DC supply or full-wave rectified, unfiltered supply. The strobe shall be capable of wall mounting to a universal backbox. Visual signaling devices shall be mounted 80" above the highest floor point or 6" below ceiling; whichever is lowest and are to be installed as per plans and specifications. Select-a-Strobe Current Draw Table: Average Current (mA) 24 volt models 16V Peak Current (mA) 24 volt models 24V 33V 16V In-Rush Current (mA) 24 volt models 24V 33V 16V 24V 33V Candela DC FWR DC FWR DC FWR Candela DC FWR DC FWR DC FWR Candela DC FWR DC FWR DC FWR 75 132 178 92 128 71 105 75 157 354 132 280 108 242 75 157 354 132 280 121 242 134 110 302 110 194 432 156 356 127 302 110 181 241 122 170 94 194 432 156 356 127 The AS24-75110 series strobes are listed for indoor use with a temperature operating range of 32°F to 120°F (0°C to 49°C). Light Output Distribution: Dimensions: Inches (mm) Degrees @ 75cd @110cd 0 75.00 110.00 5 ~ 25 67.50 99.00 30 56.25 82.50 35 56.25 82.50 40 56.25 82.50 45 56.25 82.50 50 41.25 60.50 55 33.75 49.50 60 30.00 44.00 65 26.25 38.50 70 26.25 38.50 75 22.50 33.00 80 22.50 33.00 85 ~ 90 18.75 27.50 *The sync module is rated for 3.0 amperes at 24 VDC. **Polarity shown is with NAC activated Mounting Options: Strobe with universal mounting plate and single gang box Strobe with universal mounting plate and 4" square back box 2" backbox Strobe with universal mounting plate and double gang box 4" x 4" 1-1/2" backbox Universal Mounting Plate Strobe Using the 3M-SA Sync Module: 4" x 4" 1-1/2" backbox Universal Mounting Plate Strobe Universal Mounting Plate Strobe WARNING: • Strobes must be used only on circuits with continuously operating voltage. DO NOT use strobe on coded or interrupted circuits in which the applied voltage is interrupted ON and OFF as the strobe may fail to flash. • The strobe applied voltage must be within its rated input voltage range. • Fuse ratings on signaling circuits must handle peak currents from all devices connected to those circuits. PRINTED IN U.S.A. MFG. #8850014 - REV A 08/02 PAGE 2 OF 2