GAS TESTING REQUIREMENTS IN CONFINED SPACE

Definition of a confined space

A confined space is defined as an enclosed or partially enclosed space that is not intended as a place of work

It is liable to have an atmosphere that contains harmful contaminants or not contain a safe oxygen level.

It may have contents that could cause engulfment. It may have restricted means for entry and exit. Examples include: storage tanks, tank cars, process vessels, boilers, silos, pits, pipes, sewers, shafts, ducts, shipboard spaces.

Australian Standard

AS 2865:2009

Worksafe New Zealand have accepted

Australian Standard AS 2865:2009

Confined Spaces as the standard for confined spaced entry work in NZ.

By complying with this Standard, the principles for eliminating or controlling hazards will be compatible with obligations under the Health and Safety in Employment (HSE) Act.

AS 2865:2009 Confined Spaces emphasises that before a person enters a confined space, testing is carried out to ensure that:

(a) The confined space contains a safe level of oxygen;

(b) Atmospheric contaminants in the confined space are reduced to a safe level;

(c) The confined space is free from extremes of temperature;

(d) The concentration of flammable contaminant in the atmosphere is

0% of the Lower Explosive Limit (LEL) if hot work is to be carried out, or

10% if cold work is to be carried out.

Workplace Exposure

Standards (WES)

The Workplace Exposure Standards

(WES) is intended to be used as guidelines for measuring atmospheric exposure levels of contaminants.

Employers under the HSE Act and the

HSNO Act must ensure that they have systems in place to control hazardous exposures in confined spaces this includes atmosphere monitoring.

ATMOSPHERIC HAZARDS

IN A CONFINED SPACE

TOXIC ATMOSPHERES

Contains gases, vapours, dusts or fumes that have poisonous effects on the body. Cleaning, painting or welding may produce dangerous vapours or fume. More people die from toxic gases than explosions caused by the ignition of flammable gas.

OXYGEN-DEFICIENT ATMOSPHERES

Can cause loss of consciousness and death. Oxygen deficiency can be caused by rust, fire, absorption by grain or soils, consumption by bacteria, and displacement by another gas.

FLAMMABLE OR EXPLOSIVE

ATMOSPHERES

Contains flammable gases, vapours or dusts which could be ignited by a spark or open flame. The risk of explosion or spontaneous combustion is increased if an oxygen-enriched atmosphere exists (where the oxygen content is greater than 23.5%).

There’s more to gas detection than simply owning equipment.

Every six months gas detectors should be calibrated and serviced.

APC Techsafe can provide on-site delivery of

equipment servicing, calibration, training and provide

asset management and service history support.

Scan the QR Code or visit youtube.com

and search: APC Techsafe

TRAINING IS

ESSENTIAL

FOR WORK

IN CONFINED

SPACES

Our practical training courses include:

• Plan a Confined

Space Entry

• Confined Space

Hazards

• Atmospheric Testing

• Perform Gas Tests for Energy and

Chemical Plants

See page 15-17 for more information.

www.nzsafety.co.nz | 0800 NZSAFETY (0800 697 233)

P O R T A B L E G A S D E T E C T I O N

G A S D E T E C T I O N

SINGLE GAS PERSONAL MONITORS

GASALERTCLIP EXTREME

The GasAlertClip Extreme (disposable) gas detector offers two years zero maintenance protection, with no sensor replacement, no calibration and no downtime.

• Continuous around the clock monitoring

• Compatible with MicroDock II automatic test and calibration station

2 YEAR

CODE 482152 H

481690 O

2

2

S

481660 CO

GASALERT EXTREME

The GasAlert Extreme reliably monitors for any single gas hazard within its wide range of available toxic gas models.

• Continuous LCD shows real-time

gas concentrations

• Two year field-replaceable battery and sensor

• IP 66/67

• Compatible with MicroDock II automatic test and calibration station

CODE 814995 H

2

S

481686 CO

481662 O

481663 SO

2

2

481664 Cl

2

481665 NH

3

481689 HCN

482155 PH

3

TOXIPRO ®

The ToxiPro ® is a fully serviceable reusable gas detector for monitoring a wide range of toxic gases.

• Monitors real-time gas concentrations

• Three visual alarm windows with both high visibility yellow (warning) and red (danger) alarm LED’s that flash and chase

• IP 66/67

CODE 481650 O

2

481649 CO

481655 H

2

481648 NH

S

3

481653 CI

2

482013 HCN

481652 PH

482010 SO

3

481654 NO

2

2

ALTAIR PRO

The ALTAIR Pro single gas detector provides intuitive and dependable technology when you need it.

• Tough rubberized housing

• One-button operation

• Displays information on a large, clear, backlit LCD

• Replaceable battery and sensor

• IP 66/67

• Compatible with Galaxy GX2 automatic test and calibration system

CODE 482185 CO

482186 H

482187 O

2

482188 CI

2

2

S

CODE 482190 NH

482193 PH

3

3

482194 SO

2

P O R T A B L E G A S D E T E C T I O N

BUMP TESTING AND

CALIBRATION

Bump Testing

It is recommended to bump test your gas detector before each use to confirm its ability to respond to gas.

Bump testing your gas detection instrument with calibration/bump gas is the only way to ensure the gas detector is working correctly and that you can be confident with the units operation.

Calibration

Gas detectors should be calibrated at minimum every six months.

Calibrating your instrument compensates for factors such as temperature, humidity, length of service and gas exposure (which will affect the output of your sensor) and guarantees accurate readings.

A calibration MUST be conducted if the gas detector FAILS a bump test.

www.nzsafety.co.nz | 0800 NZSAFETY (0800 697 233) 61

P O R T A B L E G A S D E T E C T I O N

FOUR GAS PERSONAL MONITORS

GASALERT MICROCLIP XT

The compact and lightweight GasAlert

MicroClip XT four-gas (H

2

S, CO, O

2

and LEL) detector provides affordable protection from atmospheric hazards.

• Continuous LCD shows real-time gas concentrations

• IntelliFlash verifies operation and compliance

• Simple one button operation

• IP 66/67

• Compatible with MicroDock II automatic test and calibration station

CODE 481684

A C C E S S O R I E S

FILTER ADAPTOR

AND 5 FILTERS

CODE 402657 GasAlert Microclip XT

481681 GasAlert Quattro

62

GASALERT QUATTRO

Rugged and reliable, the GasAlertQuattro four-gas (H

2

S, CO, O

2

and LEL) detector combines a comprehensive range of features with simple one-button operation.

• Continuous LCD shows real-time gas concentrations

• IntelliFlash verifies operation and compliance

• Interchangeable rechargeable or alkaline battery packs

• Simple one button operation

• IP 66/67

• Compatible with MicroDock II automatic test and calibration station

CODE 481680 PGD GA Quattro [O

2

, LEL, CO, H

2

S]

GASALERT MAX XT II

The GasAlertMax XT II four-gas (H

2

S, CO, O

2 and LEL) detector combines straightforward one-button operation with our robust, motorized pump for intelligent, remote sampling, ideal for confined spaces.

• Continuous LCD shows real-time gas concentrations

• Integrated sampling pump with reliable diaphragm technology

• Simple one button operation

• IP 66/67

• Compatible with MicroDock II automatic test and calibration station

CODE 403749

ALTAIR 4X

The ALTAIR 4X is a reliable four-gas (H

2

S, CO, O

2 and LEL) detector and easy to operate in any work environment, even low-light conditions.

• Greater signal stability and repeatability under changing or extreme environmental conditions

• Withstands extreme impacts with rugged polycarbonate housing

• Sensor response and clear times under

15 seconds

• MotionAlert “Man Down” sensor

• IP 67

• Compatible with Galaxy GX2 automatic test and calibration system

CODE 482077

PROTECTIVE RUBBER BOOT

CODE 480892 GasAlert Quattro

481002 GasAlert Max XT II

5 BAY CHARGERS

CODE 481067 GasAlert MicroClip XT charger

481998 GasAlert Quatro charger

481509 GasAlert Max XT II

BATTERY PACK

For GasAlert Quattro.

CODE 480454

VEHICLE CHARGER

CODE 481667 www.nzsafety.co.nz | 0800 NZSAFETY (0800 697 233)

P O R T A B L E G A S D E T E C T I O N

P O R T A B L E G A S D E T E C T I O N P O R T A B L E G A S D E T E C T I O N

CARE AND STORAGE CONFINED SPACE KITS

GAS DETECTOR

AND BUMP TEST KIT

Supplied calibrated, certified and ready to use.

• Gas detector with four sensors

(H

2

S, CO, O

2

and LEL)

• Hard carry case

• Battery and charger

• Regulator, adaptor and tube

• 34L bump test gas cylinder

CODE 482178 GasAlert MicroClip XT Confined Space Kit

482179 GasAlert Quattro Confined Space Kit

482180 GasAlert Max XT II Confined Space Kit

482238 Confined Space Kit with no instrument

CALIBRATION STATIONS

MICRODOCK II

CALIBRATION STATION

The MicroDock II automated bump test and calibration station provides simultaneous management of up to six modules.

• Quick and easy compliance - automatically maintain accurate records

• FleetManager II software included

• Automatic bump testing, calibration, record keeping and charging

• Mains or battery powered

CODE 481616 for GasAlert Max XT II

481217 for GasAlert MicroClip XT

481221 for GasAlert Quattro

481216 MicroDock II Control Module

482247 Carry case

Maintain detectors with care to insure safe operation

• Service and calibrate at least every 6 months

• Do not clean with anything other than a warm damp cloth

• Do not use or store near silicone-based products

• Keep sensor screens clean and free of debris or obstructions

• Do not poke holes in sensor screens

• Do not store in direct sunlight

(i.e. under windscreen on dashboard)

GALAXY GX2

CALIBRATION SYSTEM

Automated bump test and calibration system.

• Color touch screen for ease of setup and viewing

• Extremely simple to use; testing starts automatically without touching a single button

• Simultaneous testing of up to ten instruments

• At-a-glance indicators include low calibration gas volume, expiration warnings and test stand status.

CODE 482196 Altair 4X Test Stand

482197 Altair 4X KIT

482198 Altair Pro Test Stand

482199 Altair Pro Kit

482247 Carry case

Use protective filters to keep sensors clean and functioning correctly

www.nzsafety.co.nz | 0800 NZSAFETY (0800 697 233) 63

C A L I B R A T I O N G A S & G A S T E C T U B E S

IMPORTANCE OF

BUMP TESTING

You need to bump test every day

A bump test prior to each day’s use assures you that the sensors and alarms of your unit will function properly before entering a hazardous area.

A daily bump test should be part of the standard operating procedures when using a gas detector.

CALIBRATION AND

BUMP TEST GASES

For calibrating or bump testing multi-gas instruments with H

2

S, CO, O

2

and LEL sensors.

Ideal for use with automated docking and calibrating stations with the demand flow regulator. Alternatively for manual calibrations use with a fixed flow regulator and your instruments calibration cap.

Quad-gas mixture composition:

• Methane (CH4) – 50% LEL

• Oxygen (O

2

) – 18%

• Carbon Monoxide (CO) – 100ppm

• Hydrogen Sulfide (H

2

S) – 25ppm

NOTE: Other mixtures and single gases available on request.

CODE 481331 34L Quad-gas mixture

481015 65L Quad-gas mixture

481106 112L Quad-gas mixture

Always test before starting work, don’t assume your detector is functioning correctly.

DEMAND FLOW REGULATOR

Designed for use with instruments fitted with a sample pump or automatic calibration stations.

CODE 481566

FIXED FLOW REGULATOR

Ideal for manually calibrating and bump testing.

• 0.5 LPM flow rate

CODE 481125

64

GASTEC SAMPLING PUMP KITS

• Quick and easy sampling

• Built in tip breaker

• Supplied with case, lubricant and instructions

• Available with automatic sampling stroke counter

CODE 480122 Pump GV-100S (standard)

480123 Pump GV-110S (with counter)

GASTEC TUBES

Gastec gas detector tubes are thin glass tubes with calibration scales so you can directly read concentrations of the gases and vapours to be measured. Each tube contains detection reagent(s) that are sensitive to the target substance and quickly produce a distinct layer of colour change.

• Over 500 different tubes are available

• On-site measurements can be performed quickly and easily

• Easy to check direct reading system

• Use with the Gastec sampling pump

480122 or 480123

TOP 10 MOST POPULAR TUBES:

CODE 480318 75L Butyl Mercaptan

480311 70L Total Mercaptans

480275 3L Ammonia

480290 4LT Hydrogen Sulphide

480289 4LL Hydrogen Sulphide

480282 4H Hydrogen Sulphide

480264 2LC Carbon Dioxide

480261 2H Carbon Dioxide

480247 1LC Carbon Monoxide

480307 6L Water Vapour www.nzsafety.co.nz | 0800 NZSAFETY (0800 697 233)

W I R E L E S S G A S D E T E C T I O N

C A L I B R A T I O N G A S & G A S T E C T U B E S

WIRELESS FOUR GAS PORTABLE DETECTION

W I R E L E S S G A S D E T E C T I O N

QRAE 3

A wireless compact monitor for one to four gases including Oxygen (O

2

), Combustibles (LEL), and toxic gases that include Hydrogen Sulfide (H

2

(SO

2

S), Carbon Monoxide (CO), Sulfur Dioxide

) and Hydrogen Cyanide (HCN). The QRAE 3 can deliver wireless real-time instrument readings and alarm status 24/7.

• Man Down Alarm with real-time wireless technology

• Fully automated bump testing and calibration with AutoRAE 2 docking station

• Available in pumped or diffusion models

CODE 482282 QRAE 3 Diffusion, Wireless, (O

2

482282 QRAE 3 Pumped, Wireless, (O

2

, LEL, CO, H

, LEL, CO, H

2

S), IP67

2

S), IP65

CLOSED-LOOP WIRELESS SOLUTIONS

RAE Systems’ Closed-Loop Wireless Solutions provide real-time access to the readings and alarm status of workers’ gas monitors to enable remote stress visibility for faster incident response.

DISPLAY SCREEN

JOHN

MEG

RICK

CAPT

PAUL

LAUREN

JOSE

JACK

H

ToxiRAE PRO

(ID: John)

MultiRAE Pro

(ID: Jack)

QRAE 3

(ID: Meg)

QRAE 3

(ID: Jose)

MultiRAE Lite

(ID: Paul)

ToxiRAE PRO

(ID: Lauren)

MultiRAE Lite

(ID: Rick)

ToxiRAE PRO

(ID: Capt)

ECHOVIEW HOST

MINI CONTROLLER

ECHOVIEW HOST MINI-CONTROLLER

A rugged handheld device that can establish a self-contained wireless network with up to eight supported RAE Systems portable monitors and display their readings and alarm status in real time on an easy-to-read screen.

• Establishes a closed-loop wireless network with and displays real-time readings and alarm status of up to eight portable gas monitors at the same time

• Communication range extendable to 0.6 mi (1 km) with Mesh Routers

• Field-replaceable battery with a 10-day runtime

• Loud audible alarm, 90dB @ 30cm, red high-visibility alarm lights

• Highly-resistant to electromagnetic and radio interference

• IP-65 water and dust ingress protection rating

CODE 482284 Echoview Host

Monitor up to eight portable detectors simultaneously from a central portable monitor www.nzsafety.co.nz | 0800 NZSAFETY (0800 697 233) 65

P H O T O I O N I Z A T I O N ( P I D ) G A S D E T E C T I O N

PID GAS DETECTION

Measuring volatile organic compounds

Many explosive hazardous substances are toxic for humans, at levels markedly below the Lower

Explosive Limit (LEL) and cannot be detected at these levels by using only catalytic sensors.

Reliable detection of such substances in the ppm range can be accomplished using photoionization detectors (PIDs).

PID MONITORS

TOXIRAE PRO

• World’s smallest PID personal monitor with wireless access elevating worker protection to the next level

• Cutting edge PID with 0.1 to 2,000ppm range and

190 built-in correction factors

• Available in Industrial Hygiene (advanced) or Safety (standard) configurations

• Wireless access to real-time instrument readings and alarm status from any location

• Unmistakable five-way local and remote wireless notification of alarm conditions

• Reliable, rugged and intrinsically safe

• User replaceable sensor, filter, fan and

Lithium-ion battery

CODE 481913 CO

2

481309 PID

481462 LEL

66

A PID measures VOCs and other toxic gases in low concentrations from ppb (parts per billion) up to

15,000ppm (parts per million or

1.5% v/v by volume).

A PID is a very sensitive broadspectrum monitor however a PID is not a selective monitor and has very little ability to differentiate between chemicals.

RAE HANDHELD VOC MONITORS

MiniRAE 3000 series are the reliable volatile organic compound (VOC) Survey Monitors available. Their photoionization detector’s

(PID) ranges make them the ideal instruments for applications ranging from environmental monitoring, construction, Hazmat, homeland security, industrial hygiene, indoor air quality and military applications.

• Proven PID technology with patented sensor

• Large graphic displays

• Three second response time, ranges of ppb and ppm with improved linearity and humidity compensation

• Field interchangeable battery pack

• Integrated RAE Systems Corrections Factors list more than 200 compounds

• Loud 95dB audible alarm

CODE 482087 MiniRAE Lite

481584 MiniRAE 3000

480898 ppbRAE 3000

MULTIRAE SERIES MULTI-THREAT - DETECT AND MONITOR

• Wireless functionality - best in class detection for anywhere, anytime access to toxic and combustible gases and radiation

• Detection for more than 300 VOC’s

• Gamma Radiation sensor available

• 55 combustible gases and vapours

• 25 specific toxic gases

When deployed by RAE Systems Dedicated Wireless Network, MultiRAE instruments use a five-way notification system for gas (EC and IR sensors), radiation and man-down alarms to provide immediate and unmistakable notification system for gas, on-scene alerts while warning safety officers at a remote command centre. MultiRAE monitors provide personal and point detection capabilities for a broad range of applications and users (such as first responders, military, USAR, and industrial hygienists) making incident scenes safe by providing real-time and actionable data. Different models of the MultiRAE provide a unique combination of capabilities, including the ability to detect and meter gamma radiation in a multi-threat configuration.

MultiRAE monitors elevate worker and responder safety with real-time monitoring capabilities, parts per billion VOC detection for finding gas sources faster and an integrated man-down alarm for additional team safety.

• MultiRAE Pro - for radiation and chemical detection - please enquire for options

• MultiRAE - advanced chemical detector for up to five gases and VOC’s

• MultiRAE Lite - personal protection monitor for confined-space entry

CODE 482138 MultiRAE Lite – Pumped (O

2

481978 MultiRAE Lite – Pumped (O

2

, LEL, CO, H

, LEL, CO, H

2

2

S, CO

S, PID)

2

)

MultiRAE and MultiRAE PRO – Enquire for options www.nzsafety.co.nz | 0800 NZSAFETY (0800 697 233)