Technical Specification (F/UTP DC)

advertisement
TECHNICAL SPECIFICATION
1318 - V 23 (06/06/2016)
MULTI-LAN CAT. 5e F/UTP 24AWG
x 4P INDOOR/OUTDOOR CM
LAN Cable
Product Type
Product Family
MultiLan
Construction
Category 5e
F/UTP (shielded)
PVC - CM
General Characteristics
Features
Solid bare copper conductors insulated with the appropriated thermoplastic
material. The conductors are twisted in pairs.
Installation Environment
Indoor - Outdoor
Operation Environment
Aerial lashed or in ducts subject to temporary floods.
Compatibility
FCS products
Applications
1. Exceeds physical and electrical requirements of EIA/TIA -568-B.2
2. Cable according with RoHS directive (Restriction of Hazardous Substances)
3. Can be used with all of the following protocols.
a) GIGABIT ETHERNET, IEEE 802.3z, 1000 Mbps;
b) 100BASE-TX, IEEE 802.3u, 100 Mbps;
c) 100BASE-T4, IEEE 802.3u ,100 Mbps;
d) 100vg-AnyLAN, IEEE802.12, 100 Mbps;
e) ATM -155 (UTP), AF-PHY-OO15.000 y AF-PHY-0018.000, 155/51/25 Mbps;
f) TP-PMD , ANSI X3T9.5, 100 Mbps;
g) 10BASE-T, IEEE802.3, 10 Mbps;
h) TOKEN RING, IEEE802.5 , 4/16 Mbps;
i) 3X-AS400, IBM, 10 Mbps;
j) POWER OVER ETHERNET, IEEE 802.3af
Standards Compliance
TIA-568-C.2, ANSI/TIA/EIA-569, ISO/IEC DIS 11801, UL 444
Certifications
ETL Verified
3161909
Anatel
0037-08-0256
Anatel
2046-07-0256
Constructive characteristic Conductor
Solid bare copper with nominal diameter 24AWG.
Insulation
High density Polyethylene nominal diameter 0.94mm
Insulation Resistance
10000 MΩ/km
Number of Pairs
4 pairs 24 AWG
This informative is from authorship and exclusive property of Furukawa Industrial S.A. Its integral or partial
reproduction is banned if its authorship is not mentioned, as well as lteration of its content or context. All
specifications are subject to change without notice. Photos and drawings for illustrative purposes only.
1/3
TECHNICAL SPECIFICATION
1318 - V 23 (06/06/2016)
Pair
All pairs are twisted in such way to reduce Crosstalk effects. Each conductor is
identified according with the following color sequence.
Color Codes
Pair
Conductor "A"
Conductor "B"
1
White
Blue
2
White
Orange
3
White
Green
4
White
Brown
Cabling
All four pairs are cabled together in such way to reduce electromagnetic
inteferences making the cable lay-up.
Ripcord
A ripcord is added to easy the removal of the sheath.
Shield
Over the cable core is used an aluminum foil tape
Sheath
Inner Jacket: Flame retardant PVC
Outer Jacket: Flame retardant and sunlight resistant PVC in accordance with UL444
applied over a waterblocking tape.
Nominal Diameter
8.6mm
Color
Black
Cable Weight
84 kg/km
Physical Characteristics
Cable Flammability Rating CM:UL 1581 Vertical tray or current UL1685
Installation Temperature
0ºC up to 50ºC
StorageTemperature
-20ºC up to 70ºC
Operation Temperature
-20ºC to 60ºC
Eletrical Characteristics
Maximum Unbalance
Resistance
5%
Conductor Max. DC
Resistance at 20ºC
93.8 Ω/km
Maximum Mutual
Capacitance 1kHz
56 pF/m
3.3 pF/m
Max. Unbalance
Capacitance Pair x Ground
Characteristic Impedance 100±15% Ω
Maximum Propagation
Delay
545ns/100m @ 10MHz
This informative is from authorship and exclusive property of Furukawa Industrial S.A. Its integral or partial
reproduction is banned if its authorship is not mentioned, as well as lteration of its content or context. All
specifications are subject to change without notice. Photos and drawings for illustrative purposes only.
2/3
TECHNICAL SPECIFICATION
1318 - V 23 (06/06/2016)
Maximum Delay Skew
45ns/100m
Dieletric strength
Between conductors
Between each conductor and shield
2500 VDC/3s
2500 VDC/2s
NVP
68%
Transmission Performance
Atenuation @
Power
Power
Return
NEXT
ELFEXT
20°C
Sum NEXT
Sum ELFEXT
Loss
Frequency(MHZ)
(dB)
(dB)
(dB/100m)
(dB)
(dB)
(dB)
Minimal
Minimal
Maximum
Minimal
Minimal Minimal
0.772
1.8 67.0 64.0 ---
--- --- 1
2.0
65.3
62.3
63.8
60.8
20.0
4
4.1
56.3
53.3
51.8
48.8
23.0
8
5.8
51.8
48.8 45.7
42.7
24.5
10
6.5
50.3
47.3
43.8
40.8
25.0
16
8.2
47.2
44.2
39.7
36.7
25.0
20
9.3
45.8
42.8
37.8
34.8
25.0
25
10.4
44.3
41.3
35.8
32.8
24.3
31.25
11.7
42.9
39.9
33.9
30.9
23.6
62.5
17.0
38.4
35.4
27.9
24.9
21.5
100
22.0
35.3
32.3
23.8
20.8
20.1
The transmission characteristics are based on measurements made cable samples
taken from reels and placed over a flat non-conductive surface.
Marking
INNER JACKET:
FURUKAWA MULTILAN F/UTP CAT. 5e 24AWGx4P CM -- ETL VERIFIED TO TIA-568-C.2
CATEGORY 5e -- ANATEL 0037-08-0256 YAAMMDDHHmm **m
OUTER JACKET:
FURUKAWA MULTI-LAN F/UTP CAT. 5e 24AWGX4P CM INDOOR/OUTDOOR -- ANATEL
2046-07-0256 --- YAAMMDDHHmm **m
Where:
Y - Process traceability
AAMMDDHHmm - :AA-Year MM-Month DD - Day HH - Hour; mm - minute
** - length in meters
Package
Package Type
Wood reel
Standard Lengh
1000 meters
Observations
Developing cables for outdoor use solves problems related to the installation
environment. However is of great importance to install systems to protect the cable
agains electrical discharges, surges and transient voltages which are compatible
with the cable's category.
This informative is from authorship and exclusive property of Furukawa Industrial S.A. Its integral or partial
reproduction is banned if its authorship is not mentioned, as well as lteration of its content or context. All
specifications are subject to change without notice. Photos and drawings for illustrative purposes only.
3/3
Download